SLY Automatic Seed Counter Instruction. Please carefully read the instruction before use product!

Size: px
Start display at page:

Download "SLY Automatic Seed Counter Instruction. Please carefully read the instruction before use product!"

Transcription

1 SLY Automatic Seed Counter Instruction Please carefully read the instruction before use product!

2 SLY Automatic Seed Counter Instruction 1. Automatic Seed Counter action Automatic Seed Counter can automatic count kinds of grain by setting number. In agriculture it is mainly used in grain count, exp. Rice, wheat, Sorghum, com, vegetables seed and so on. When it reaches to the setting number the instrument stop work itself. This instrument is widely used in institute of Agricultural Sciences, the agricultural universities, colleges and institutes, the seed system, in the grain department inspects the seed target, the survey weight of a thousand seeds, germinate counts and sows seeds counts and so on. The accurate automatic count grain of functions have undertaken (he artificial provides the convenience for the user. 2. Work principle The instrumentation controls by the microcomputer chip, Matches by membrane pressed key operation. (I) Electromagnetic vibration install: The seed puts on the material plate, to be helix. (2) In helix trough rise seed, fall from the fall exit. Projects through the photo electricity transformation area lo the silicon photoelectric generator on his the electric current change, obtains the photo electricity after the pulsation enlargement reshaping lo count the pulsation, sends in the microcomputer 10 control counts the display circuit. (3) Count display action by microchip control, count signal enters microchip from the outside center fracture, in microchip finish the number processing and storage. The microchip control numerical code tube position chooses signal 74LSI38 to carry on the position to the digital tube to elect. Microchip change to read signal TXD put to74lsi64, then move to LED display. We can read from the LED display screen.

3 (4) Pre-set stop action by microchip control too, when the number is the same as pre-set number, stop work, off microchip cut outside, so stop work, LED show the pre-set number. (5) Pre- value and Electric circuit check, press set button, the digital tube demonstrated cuts the establishment environment, by up, down, left, right button ( up, down add and reduces number, left, right set number the displacement in position) finish press set button, Promotes the establishment environment, the digital tube show 00000u The user may examine the set number, press look button Examined the function to be able to the user formerly numerical code tube demonstration automatic 3. Instrument contour, structure 1.Tight button 2.Sample plate 3.Sample entrance 4. Sample exit 5. LBD display 6. Hopper 7.Up, Down, Left, Right button 8.Set button 9. Look up button 10.Power instruction 11.Revise I 12. Revise II 13. Zero button 14.Count button 15.Speed setting

4 4. Instrument Use 1. Sample plate: choose the plate by the samples size, put the hole of the grain fall to aim pipeline then layside tightness with the tight knob. 2. Set: press power button turn on power. LED display 00000,press set button set the counter number, up, down add and reduces number, left, right set number the displacement in position, press look button, LED show the set number. 3. Automatic correct: In order to confirm the instrument operation the accuracy. Automatic correct 1, Low frequency. Automatic correct 2, High frequency. Exp. set number is 1000, press Automatic correct 1 or Automatic correct 2, let the display number up to set number1000, stop work, it means work normal. If it continue work after to the set number, it means work abnormal. 4. Zero: when display screen has number, press zero button. Display screen will show Count: press count button, the instrument start to count. 6. Speed set: it has 1-7 for setting, to set the count speed. I is slowest, 7 is Quickest, you can change it by different sample. Instrument whole operation: Installs the instrument, put the sample to the sample plate, put a container in the exit, set the count number, press count button, you can set the count speed, when count number to the set number, the instrument stop work automatic 0 When the second operation,press zero button. 5. Matters needing attention 1. Count sample: Because mixes in the seed sample also able to form the projection in the light pipe to count, so the sample please don t have mixes. 2. Choose the suitable plate. Because of the correct count requests seed in a line, fall in turn, fall a grain to have a projection, counts I grain. If plates

5 track widths are big, two grains of or two grain of above seeds, but forms a projection on the light pipe, the mistake counts is only 1 grain. 3. Do not put too much sample in plate. 4. Does when willfully counts, the pre-placed value should be bigger than counts the value. 5. When the work voltage changes, the speed must change. 6. If the machine doesn t work normal the pressed key does not work and so on please restarts. 6. Instrument maintenance 1. The starting machine numerical code tube is not bright: check the plug, the electric wire, the switch and the fuse. 2. Automatic correct pre-set normal, count number abnormal: Exchanges the light bulb. 3. The material plate feeding is slow, sound: Adjusts vibration following ferrite core position. Let the electro-magnet gap in 0.5mm. 4. Exit obstruction, the sample is wide than 4mmor to long: take out the plate then use 2 wooden sliver removes. 7. Technical specification 1. Count Range: small sample: mm x mm Big sample: 3 10x3 12mm 2. Count accurate: big sample 2/1000 (speed action) Small sample: 4/1000 (speed action) 3. Count speed: >= 1000 /3min (this is in 2if you want fast you can change to 3-7)

6 4. Count number range: LED display read direct. 5. Pre-set stop: every number, not count 6. Automatic correct: f=l-2hz f=10-20hz. 7. Size: 196X254 X 150mm 8. Power Resources: 220 土 20V, 50Hz 9. Power Require: 20W 10. Continuous working time: >= 5 hours 11. Working conditions: Atmospheric pressure: 750±30 mm mercury column Ambient temperature: 0-40 Relative humidity: 20 less than 80% 12. Action: Pre- value Setting, Electric circuit correction automatic, willfully counts, Pre- value stop automatic. Model SLY-A SLY-B SLY-C Action SLY- A: For small sample such as rice, wheat, rape, vegetables, flowers and plants, tobacco. SLY- B: For big sample such as com, bean, and Sunflower seed. SLY-C: Both big sample & small sample.

7 Equip 8. Packing List Model SLY-A SLY-B SLY-C Mainframe 1 Mainframe 1 Mainframe 1 Small 1 Big sample 1 Big plate 1 sample plate plate Middle sample Plate 1 Small sample plate Power line 1 Power line 1 Power line 1 Knob 1 Knob 1 Knob 1 6V, 0.04A 1 6V, 0.04A 1 6V, 0.04A 1 light bulb light bulb light bulb Φ5x20 fuse 2 Φ5x20 fuse 2 Φ5x20 fuse 2 Instruction 1 Instruction 1 Instruction 1 1

IMCGS-2S series VIBRATING HOPPER INCLINED SCREW CONVEYOR OPERATING INSTRUCTION

IMCGS-2S series VIBRATING HOPPER INCLINED SCREW CONVEYOR OPERATING INSTRUCTION IMCGS-2S series VIBRATING HOPPER INCLINED SCREW CONVEYOR OPERATING INSTRUCTION 1 1. Brief description IMCGS-2S series is an economical and convenient conveyor with rectangle, vibrating hopper. The characteristics

More information

The Discussion of this exercise covers the following points: Introduction How a tuning fork works Industrial applications. How a tuning fork works

The Discussion of this exercise covers the following points: Introduction How a tuning fork works Industrial applications. How a tuning fork works Exercise 3 Vibrating Level Switch EXERCISE OBJECTIVE Learn the working principle of vibrating level switches and learn how to use the vibrating level switch, Model 46933. DISCUSSION OUTLINE The Discussion

More information

STEINDORFF NYMC C. Comparison Microscope. Operating Instructions. A. Features and Functions

STEINDORFF NYMC C. Comparison Microscope. Operating Instructions. A. Features and Functions 1 NYMC0035000C Comparison Microscope Operating Instructions A. Features and Functions Through optical enlargement, this comparison microscope, can help the user to observe clearly, by looking into the

More information

COIN COUNTER & SORTER

COIN COUNTER & SORTER COIN COUNTER & SORTER ADVANTAGE: Large Blue LCD display Fast counting speed of 600 units per minute Large Hopper capacity of 1000-1300 units of coins RH-850 is high technical product with light, electronic

More information

ADAE portable X ray machine Operation manual

ADAE portable X ray machine Operation manual ADAE portable X ray machine Operation manual CONTENTS ABOUT THE SYMBOL----------------------------------------------------------3 INTRODUCTION-----------------------------------------------------------------4

More information

Operation Instructions

Operation Instructions High Speed Coin Counter With Automatic Hopper Operation Instructions Content 1. Introduction. 3 2. Whole Machine Figure. 3 3. Technical Specifications 4 4. Key Panel..4 5. Precautions 5 6. Operation Procedures..6

More information

DIRECTORATE FOOD SAFETY AND QUALITY ASSURANCE

DIRECTORATE FOOD SAFETY AND QUALITY ASSURANCE DIRECTORATE FOOD SAFETY AND QUALITY ASSURANCE AGRICULTURAL PRODUCT ACT, 1990 (ACT No. 119 OF 1990) LIST OF PUBLISHED, AND REQUIREMENTS LAST UPDATE: March 2017 Codes E = Export L = Local @ Administered

More information

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics Dewpoint-guided Power Controller for Glass and Handrail Heaters Front view Characteristics Dew point-guided power controller for cost-optimized operation of glass and handrail heaters Digital display of

More information

Screwfeeder Troubleshooting Guide

Screwfeeder Troubleshooting Guide Symptom General Cause Specific Cause Solution Illustration No Screws are being fed to the screwdriver Screw jam in screw delivery tubing Insufficient Screw Blast to deliver screw Adjust Screw Blast Inline

More information

Process/Mini. English IMPORTANT NOTE. Installation and Operation Manual. General Purpose Light Curtain with 30 mm resolution

Process/Mini. English IMPORTANT NOTE. Installation and Operation Manual. General Purpose Light Curtain with 30 mm resolution Installation and Operation Manual Process/Mini General Purpose Light Curtain with 30 mm resolution English manufactured under ISO 9001: 2000 IMPORTANT NOTE FOLLOW THE INSTRUCTIONS GIVEN IN THIS MANUAL

More information

E1000/E1400 Horizontal Stretch Wrapping Machine E1000/E1400 MODEL. Horizontal Stretch Wrapping Machine USER MANUAL. *

E1000/E1400 Horizontal Stretch Wrapping Machine E1000/E1400 MODEL. Horizontal Stretch Wrapping Machine USER MANUAL. * E1000/E1400 MODEL E1000/E1400 Horizontal Stretch Wrapping Machine Horizontal Stretch Wrapping Machine USER MANUAL 1 CONTENT I. Application Note...2 II. Important Alert...2 III.Technical Parameter...4 IV.

More information

15 Industrial Tools. Recognized by Professionals. Work Together. Scribing Needle. Replacement of Scribing Needle. Features. Use A B

15 Industrial Tools. Recognized by Professionals. Work Together. Scribing Needle. Replacement of Scribing Needle. Features. Use A B Industrial Tools Recognized by Professionals Work Together With battery : Sleeve package Card Box Clear package Scribing Needle 74444 74468 78638 78646 7864 7860 7444 74469 Retracts needle by turning body

More information

FD 125 Large-Format Card Cutter

FD 125 Large-Format Card Cutter FD 125 Large-Format Card Cutter 3/201 OPERATOR MANUAL Page 2 Table of Contents SAFETY PRECAUTIONS... 4 Introduction... 5 Specifications... 5 Accessories... 5 Major Components and Assemblies... 6 Control

More information

MINIATURE RELAY FOR WIDER APPLICATIONS

MINIATURE RELAY FOR WIDER APPLICATIONS TÜV Rheinland HJ MINIATURE RELAY FOR WIDER APPLICATIONS HJ RELAYS FEATURES contact arrangements Form C (for A 0 V AC), Form C (for 0 A 0 V AC)* Excellent contact reliability by Au plating Environmentally

More information

Vinyl Cutter Instruction Manual

Vinyl Cutter Instruction Manual Vinyl Cutter Instruction Manual 1 Product Inventory Inventory Here is a list of items you will receive with your vinyl cutter: Product components (Fig.1-4): 1x Cutter head unit complete with motor, plastic

More information

SEPARATOR P20G TYPE USER S MANUAL

SEPARATOR P20G TYPE USER S MANUAL SEPARATOR P20G TYPE USER S MANUAL 1 2 Contents 1. APPLICATION... 5 2. SEPARATOR SET... 5 3. OPERATIONAL SAFETY... 6 4. FITTING... 7 4.1. Fixing Way... 7 4.2. External Connection Diagrams... 8 5. SERVICE...

More information

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK Efcon Water Installation & User Manual Electro Magnetic Flowmeter (EMF) Page 1 Table of content Page 1.1 General 3 1.2 Application area 4 1.3 Transportation 4 1.4 Principle of Operation 4 1.5 Product Description

More information

John Deere 9570STS, 9650STS, 9660STS, and 9750STS Grain Tank Cross Auger Trough Liner EXOPLATE INSTRUCTION MANUAL

John Deere 9570STS, 9650STS, 9660STS, and 9750STS Grain Tank Cross Auger Trough Liner EXOPLATE INSTRUCTION MANUAL PLEASE READ THE ENTIRE INSTRUCTION SHEET BEFORE STARTING INSTALLATION. PLEASE REFER TO THE OPERATORS MANUAL FOR YOUR SPECIFIC COMBINE FOR PERTINENT SAFETY PRECAUTIONS THE TERMS. LEFT, RIGHT, FRONT, & REAR

More information

COFFEE LABORATORY WHITE STONE VA TEL

COFFEE LABORATORY WHITE STONE VA TEL 1. Technical specifications 4. Operating instructions: Octagon 200 Copyright 2015 by Endecotts Ltd. 21 1. Setting up Technical specifications SIEVE SHAKER MODEL: Octagon 200 General Information The sieve

More information

WRIST GAMMA INDICATOR РМ1208M OPERATING MANUAL

WRIST GAMMA INDICATOR РМ1208M OPERATING MANUAL WRIST GAMMA INDICATOR РМ1208M OPERATING MANUAL CONTENTS 1 Introduction.... 3 2 DESCRIPTION AND OPERATION OF THE INDICATOR.... 4 2.1 Application of the indicator..... 4 2.2 Delivery kit..... 5 2.3 Specifications...

More information

Analog Technologies VC99. Multimeter FEATURES

Analog Technologies VC99. Multimeter FEATURES FEATURES LCD Display Max Display: 6000(3 6/7) Digits Automatic Polarity, Unit Symbol and 61 Section Analog Display Measurement Method: Double Integral A/D Conversion Sampling Rate: Approx.3 times/sec Over-Range

More information

FOR YOUR SAFETY: READ ALL INSTRUCTIONS CAREFULLY

FOR YOUR SAFETY: READ ALL INSTRUCTIONS CAREFULLY MODEL 2020F FOR YOUR SAFETY: READ ALL INSTRUCTIONS CAREFULLY Table of Contents General safety instructions for Power Tools 1 Main specification 2 Unpacking and checking contents 2 List of loose parts in

More information

Grain Tank Cross Auger Trough Liner for John Deere 9400 / 9500 Combine

Grain Tank Cross Auger Trough Liner for John Deere 9400 / 9500 Combine www.polyskid.com P. O. Drawer 349, Monticello, GA. 31064 Phone: 800-542-7659, Fax: 706-468-2881 E-Mail: polytech@polyskid.com Grain Tank Cross Auger Trough Liner for John Deere 9400 / 9500 Combine FOR

More information

ADDMAS CORIOLIS MASS FLOW METER

ADDMAS CORIOLIS MASS FLOW METER ADDMAS CORIOLIS MASS FLOW METER 1. General ADDMAS Series Coriolis Mass Flow meter (here after we call CMF ) is designed according to the coriolis principle. It can be widely used for the process detecting

More information

-_.-~ Sample. HIGH SENSITIVITY TYPE TOTAL REFLECTION X-RAY SPECTROMETER SYSTEM Wafer Surface Analysis System --

-_.-~ Sample. HIGH SENSITIVITY TYPE TOTAL REFLECTION X-RAY SPECTROMETER SYSTEM Wafer Surface Analysis System -- THE RIGAKU JOURNAL VOl. 8 / NO. 1 / 1991 HIGH SENSITIVITY TYPE TOTAL REFLECTION X-RAY SPECTROMETER SYSTEM 3726 --Wafer Surface Analysis System -- 1. Introduction System 3726 utilizes the total reflection

More information

Operation Manual. Chap. 1 Attention. Please read the attention carefully before operating the machine.

Operation Manual. Chap. 1 Attention. Please read the attention carefully before operating the machine. Chap. 1 Attention Please read the attention carefully before operating the machine. 1. No magnetic devices should be placed in the vicinity of the plotter, specifically the carriage. 2. Prevent from dropping

More information

Operation manual. Thanks very much for purchasing this. cutter/plotter. To ensure you make best use of your machine,

Operation manual. Thanks very much for purchasing this. cutter/plotter. To ensure you make best use of your machine, Operation manual Thanks very much for purchasing this cutter/plotter. To ensure you make best use of your machine, please read this manual carefully and thorughly beforhand. IMMEDIATELY power off the machine

More information

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use.

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use. 98585A High Intensity LED Stroboscope Digital Tachometer DT-361/365 Instruction manual Be sure to read before use. Before use, please carefully read these safety precautions as well as instructions, and

More information

Pneumatic Grain Conveying

Pneumatic Grain Conveying Pneumatic Grain Conveying High Pressure Blowers Moving agriculture ahead High Pressure Blowers Outlet cyclone Outlet cyclone Blower Receiving hopper Blower Injector Pressure conveying systems are used

More information

Model: &

Model: & 600A True RMS Digital Clamp Meter Model: 72-3097 & 72-3099 1 CONTENTS Page Number Details 3 Important Safety Information 4 Product overview 4 Key Functions 5 General Specification 5 Electrical Specification

More information

HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL. Huazheng Electric Manufacturing(Baoding) Co.,Ltd

HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL. Huazheng Electric Manufacturing(Baoding) Co.,Ltd HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL Huazheng Electric Manufacturing(Baoding) Co.,Ltd Safety Terms and Symbols This manual may contain the terms: Warning! Indicate the conditions

More information

OPERATION MANUAL OF MODEL TH2681/A HIGH RESISTANCE TESTER

OPERATION MANUAL OF MODEL TH2681/A HIGH RESISTANCE TESTER OPERATION MANUAL OF MODEL TH2681/A HIGH RESISTANCE TESTER Changzhou Tonghui Electronic Co., Ltd Addr: No.3 Tianshan Rd., New District, Changzhou Zip: 213022 Tel: 86-519-5132222 Fax: 86-519-59972 Http://

More information

7. Operating instructions: EFL 300

7. Operating instructions: EFL 300 7. Operating instructions: EFL 300 Copyright 2015 by Endecotts Ltd. 59 1. Setting up Technical specifications SIEVE SHAKER MODEL: EFL 300 General Information The new EFL 300 combines the best features

More information

AutoSeal FD 2002/FD 2032 FE 2002/FE 2032 OPERATOR MANUAL FIRST EDITION

AutoSeal FD 2002/FD 2032 FE 2002/FE 2032 OPERATOR MANUAL FIRST EDITION AutoSeal FD 2002/FD 2032 FE 2002/FE 2032 10/2012 OPERATOR MANUAL FIRST EDITION TABLE OF CONTENTS SUBJECT PAGE DESCRIPTION 1 SPECIFICATIONS 1 UNPACKING 2 2000/2032 Components 2 Optional Conveyor Components

More information

Operators Manual (Manual A)

Operators Manual (Manual A) CD201 SINGLE COLUMN CARD DISPENSER Operators Manual (Manual A) Contents A1 Scope... 1 A2 Specifications... 1 A3 Installation... 2 3.1 Unpacking and inspection... 2 3.2 Opening and closing the door... 2

More information

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type PAGE 2 of 6 2.14 Main Cable Type HO7RN-F4G10-15 Metres each 2.15 (a) O/P Voltage-350V(Max.) (b) O/P Current 150A(Max.) 2.16 Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type 2.17

More information

1. Introduction 1.1 Features: CTS24 Digital Tesla meter is one of our products series after CTS3, it has a uniqite selection system, a large

1. Introduction 1.1 Features: CTS24 Digital Tesla meter is one of our products series after CTS3, it has a uniqite selection system, a large 1. Introduction 1.1 Features: CTS24 Digital Tesla meter is one of our products series after CTS3, it has a uniqite selection system, a large measurement range, an interchangeable probe. It is composed

More information

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES High Carrying Current Type Miniature Low Profile Automotive Relay CP RELAYS POWER TYPE Sealed 13.1 14.1 9..374 FEATURES Maximum carrying current of 3 A (4 mw type, 1 V applied)

More information

STEINDORFF Digital LCD Biological Microscope

STEINDORFF Digital LCD Biological Microscope Digital LCD Biological Microscope -1260/ -1261 Instruction Manual Thanks for purchasing this digital LCD biological microscope. This user s manual is for item number -1260 & -1261. In order to operate

More information

Pre-assembly preparation

Pre-assembly preparation Thank you for purchasing this console table barbier. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Pre-assembly preparation Please ensure

More information

Ultrasonic Machining. 1 Dr.Ravinder Kumar

Ultrasonic Machining. 1 Dr.Ravinder Kumar Ultrasonic Machining 1 Dr.Ravinder Kumar Why Nontraditional Processes? New Materials (1940 s) Stronger Tougher Harder Applications Cut tough materials Finish complex surface geometry Surface finish requirements

More information

Variable Transformers Product Design & Engineering Data

Variable Transformers Product Design & Engineering Data Variable Transformers Product Design & Engineering Data Product Design & Engineering Data Type 1010B Cutaway General Information STACO ENERGY PRODUCTS CO. is a leading manufacturer of variable transformers,

More information

Operating Guide. HT25 Multi Side Tabber & Stamp Affixer. HASLER America s better choice. Mailing Systems And Solutions

Operating Guide. HT25 Multi Side Tabber & Stamp Affixer. HASLER America s better choice. Mailing Systems And Solutions Operating Guide Mailing Systems And Solutions HASLER America s better choice HT25 Multi Side Tabber & Stamp Affixer An ISO 9001 Quality System Certified company Rev. 8/25/2010 Please record the following

More information

CSNC CARBIDE CIRCULAR SERIES

CSNC CARBIDE CIRCULAR SERIES CSNC CARBIDE CIRCULAR SERIES HIGHLY EFFICIENT AND PRODUCTIVE HIGH SPEED CIRCULAR SAWING MACHINES CARBIDE SAWS DO THE WORK OF FIVE CONVENTIONAL FACTORY BAND SAWS, WITHOUT SACRIFICING QUALITY. GET THE CLOSE-CUT

More information

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0.

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0. SERIES Ultra-compact Digital Panel Controller CA Convenient s packed in a small body! Ultra-compact Large display Flexible scaling Conforming to EMC Directive Ultra-compact size of W 48 H 24 D 65.5 mm

More information

DRILLING CATALOG. GRAINGER.COM/CHOICE l Grainger

DRILLING CATALOG. GRAINGER.COM/CHOICE l Grainger DRILLING CATALOG GRAINGER.COM/CHOICE l 1.800.Grainger DRILL PRESSES BENCH fact sheet 8" BENCH DRILL PRESS Dayton's light duty drilling machine combines performance and economy into one. It s an ideal choice

More information

Atomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL. Version 1.0

Atomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL. Version 1.0 Atomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL Version 1.0 Thank you for purchasing our HFX90V portable veterinary x-ray unit. We are confident that you will be pleased with the radiographs

More information

Installation Instructions (For Dealer or Contractor)

Installation Instructions (For Dealer or Contractor) 9701R870HH9001 HOME USE LOSSNAY TYPE Installation Instructions (For Dealer or Contractor) Before proceeding with the installation work, be sure to read through these instructions. The installation work

More information

DICTATOR RTS Tube Door Closer

DICTATOR RTS Tube Door Closer Tube Door Closer RTS v long DICTATOR RTS Tube Door Closer The "Invisible" Door Closer The DICTATOR RTS tube door closer is built into the door and therefore is as good as invisible. The joint can only

More information

DCB-S SERIES BANDSAWS DURMA

DCB-S SERIES BANDSAWS DURMA DCBS SERIES BANDSAWS BETTER PARTS BETTER PROFITS DCBS SERIES BANDSAWS STANDARD EQUIPMENT Twoway 45 Angle Adjustable Clamp Hydraulic Vice Electronic Variable Cutting Speed Adjustment with Inverter Bimetal

More information

INTRODUCTION CHAPTER 1

INTRODUCTION CHAPTER 1 TABLE OF CONTENTS Introduction... 3 Package Contents... 5 Design... 7 Key Functions... 9 Grain Species and Measuring Ranges....11 First Steps...13 Measurement...15 Modification...19 Setup...21 Replacing

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

Scanning Laser Range Finder

Scanning Laser Range Finder Date: 2011.11.25 Scanning Laser Range Finder UTM-30LX-EW Specification Symbol Amendment Details Amendment Date Amended by Number Approved by Checked by Drawn by Designed by MORI KAMITANI TAGAMI HINO Drawing.

More information

Electric Skein Winder

Electric Skein Winder Electric Skein Winder Assembly and Use Package Contents 1 - Triangular Body (w/ motor) 1 - Cross Arm 1 - Left Foot (w/ yarn guide) 1 - Right Foot 1 - Adjustable Finger (w/ yarn clip) 3 - Adjustable Fingers

More information

DCB-DM SERIES BANDSAWS DURMA

DCB-DM SERIES BANDSAWS DURMA BETTER PARTS BETTER PROFITS STANDARD EQUIPMENT Hydraulic Vice Synchronized Cutting Arm & Clamp System Bilateral 60 Angled Cut Digital Readout of Turn Table Motorized Turn Table Electronic Variable Cutting

More information

MTV-1-CP 230 VAC POTENTIOMETER WITH MIN & MAX SETTINGS, DRY CONTACT. Mounting and operating instructions

MTV-1-CP 230 VAC POTENTIOMETER WITH MIN & MAX SETTINGS, DRY CONTACT. Mounting and operating instructions & MAX SETTINGS, DRY CONTACT Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 WIRING

More information

SPECIFICATION & USER'S GUIDE

SPECIFICATION & USER'S GUIDE SPECIFICATION & USER'S GUIDE ( LED Power Supply, LED driver, Switching Power Supply) Thank you for using our power supply, please read the below information carefully before using this power supply! 1

More information

Chip Inductor INTRODUCTION FEATURE AND APPLICATION. Feature. Application

Chip Inductor INTRODUCTION FEATURE AND APPLICATION. Feature. Application INTRODUCTION Multilayer Chip Inductor is an electronic part that uses in resonance circuit, for noise suppression and for impedance matching in the electrical circuit. SAMSUNG Electro-mechanics has 2 series

More information

Contents. Ⅰ. General. Ⅱ. Open-package Inspection. Ⅲ. Safety Note. Warning:

Contents. Ⅰ. General. Ⅱ. Open-package Inspection. Ⅲ. Safety Note. Warning: ontents 1. General 1 2. Open-package Inspection. 1 3. Safety Note.... 1 4. Description of Safety Symbols. 2 5. Description of Instrument Panel and Pushbutton unctions 2 6. Other unctions. 3 7. Property..

More information

Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection

Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection Ik-Keun PARK 1,a, Yong-Kwon KIM 2,b, Sae-Jun PARK

More information

Dawson DDM190. Digital Multimeter User s Manual

Dawson DDM190. Digital Multimeter User s Manual Dawson DDM190 Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories.. Error! Bookmark not defined. Safety Information... 7

More information

INTERPLANT STANDARD - STEEL INDUSTRY. MEASUREMENT OF MOISTURE CONTENT (Second Revision) IPSS: (Second Revision)

INTERPLANT STANDARD - STEEL INDUSTRY. MEASUREMENT OF MOISTURE CONTENT (Second Revision) IPSS: (Second Revision) INTERPLANT STANDARD - STEEL INDUSTRY IPSS MEASUREMENT OF MOISTURE CONTENT (Second Revision) IPSS: 2-07-077-13 (Second Revision) No Corresponding IS Formerly: IPSS:2-07-077-93 0. FOREWORD 0.1 This Interplant

More information

15" 500W self-powered subwoofer

15 500W self-powered subwoofer 15" 500W self-powered subwoofer USER GUIDE 10349 - Version 1 /01-2015 English SRSUB15A - 15" 500W self-powered subwoofer 1 - Safety information Important safety information This unit is intended for indoor

More information

Glass & Soil Analysis

Glass & Soil Analysis Glass & Soil Analysis Glass Evidence Class evidence Glass evidence is considered trace evidence Most common substance submitted for trace analysis Valuable because it does not degrade easily Characterizing

More information

Perfmaster Sprint

Perfmaster Sprint Perfmaster Sprint 01-2016 CONTENTS CARE AND MAINTENANCE 1 SAFETY PROCEDURES 1 SPECIFICATIONS 1 COMPONENT IDENTIFICATION 2 MACHINE CONTROLS 3 MAIN POWER 3 SPEED CONTROL 3 EMERGENCY STOP 3 DELIVERY TRAY

More information

Virutex Edge Banders Operating Manual Model EB25

Virutex Edge Banders Operating Manual Model EB25 50 HILL STREET # 509 SOUTHAMPTON, NY 11968 PHONE: 631-537-3052 800-868-9663 FAX: 631-537-2396 VIRUTEX@AOL.COM WWW.VIRUTEX.COM Virutex Edge Banders Operating Manual Model EB25 1- Initial Set up 2- Learn

More information

0.01kV (0 to ±0.99 kv)

0.01kV (0 to ±0.99 kv) Handheld Electrostatic Meter Series IZH10 Easy-to-use handheld electrostatic meter Rated charge amount range: ±20.0 kv Minimum display unit: 0.1kV (±1.0 to ±20.0 kv) Check the current situation before

More information

OM FL400. Reflected Light Fluorescence Microscope. Instruction Manual. Please read instructions carefully before using microscope.

OM FL400. Reflected Light Fluorescence Microscope. Instruction Manual. Please read instructions carefully before using microscope. OM FL400 Reflected Light Fluorescence Microscope Instruction Manual Please read instructions carefully before using microscope. Contents Safety ---------------------------------------------- 2 Parts List

More information

6300T Series 3mm (T-1) LED SMD Right Angle Circuit Board Indicator

6300T Series 3mm (T-1) LED SMD Right Angle Circuit Board Indicator TM 63T Series 3mm (T-1) LED SMD Right Angle Circuit Board Indicator 63T75 - /Green Single level Surface Mount CBI, available in five different LED colors LONG LIFE LED Applications Industrial Infrastructure

More information

OPERATING AND MAINTENANCE INSTRUCTIONS FOR CONSTANT CURRENT RECTIFIERS USING SATURABLE CORE REACTORS

OPERATING AND MAINTENANCE INSTRUCTIONS FOR CONSTANT CURRENT RECTIFIERS USING SATURABLE CORE REACTORS OPERATING AND MAINTENANCE INSTRUCTIONS FOR CONSTANT CURRENT RECTIFIERS USING SATURABLE CORE REACTORS I. WARNING Operating personnel should observe the following before attempting to operate or adjust the

More information

18W Nightsensor Bulkhead

18W Nightsensor Bulkhead 18W Nightsensor Bulkhead Cat No. ECO18P instructions Instructions A Retaining clip B Vertical location Sensor Horizontal location Sensor Wall fixing hole C Wall fixing hole D Wall fixing hole Sensor Vertical

More information

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External

More information

General Wood Shop Notes

General Wood Shop Notes General Wood Shop Notes Restricted Materials No METAL or BONE of any kind on any machine or in the room o See additional restrictions individual machine All reclaimed and other than new lumber must be

More information

Operating instructions OI/FPD350-EN Rev. H. FPD350 Torbar Averaging pitot tubes

Operating instructions OI/FPD350-EN Rev. H. FPD350 Torbar Averaging pitot tubes Operating instructions OI/FPD350-EN Rev. H FPD350 Torbar The Company We are an established world force in the design and manufacture of measurement products for industrial process control, flow measurement,

More information

Compliant with European standards 1a/1c 6A Slim power relays

Compliant with European standards 1a/1c 6A Slim power relays PF (APF) VDE Compliant with European standards 1a/1c 6A Slim power relays PF RELAYS (APF) RoHS compliant FEATURES 1. High density mounting with mm.197 inch width Space saved with mm.197 inch slim type

More information

How to maintain your NeumanTree Brilliant Lighting System and make your lights last longer

How to maintain your NeumanTree Brilliant Lighting System and make your lights last longer How to maintain your NeumanTree Brilliant Lighting System and make your lights last longer The golden rule in maintaining your lighting system is to simply replace any light bulb that has burned out as

More information

FBX1104P FBX1104 FBX1106P FBX1106

FBX1104P FBX1104 FBX1106P FBX1106 FBX1104P FBX1104 FBX1106P FBX1106 Second edition : September 2004 No. 040037 INTRODUCTION Thank you for your purchasing Kansai Special's FBX Series. Read and study this instruction manual carefully before

More information

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL Ω CONTENTS CONTENTS 1. SAFETY INFORM...1 4.4 Range Transform...10 1.1 Preliminary...1 4.5 Auto Power Off...10 1.2 During use...2 4.6 Preparation For Measurement...11

More information

KN-Q10 Assembly Manual

KN-Q10 Assembly Manual KN-Q10 Assembly Manual Translated by Adam Rong, BD6CR/4 with permission from Ke Shi, BA6BF Edited by Stephen, VK2RH Revision B, Oct 14, 2010 Thank you for purchasing the KN-Q10 4 Band SSB/CW Dual Mode

More information

Installation and Operating Instructions for Phase Demodulator Type _.2

Installation and Operating Instructions for Phase Demodulator Type _.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/EU and the Electromagnetic Compatibility (EMC)

More information

DURMA BANDSAWS HB & DCB SERIES

DURMA BANDSAWS HB & DCB SERIES DURMA BANDSAWS HB & DCB SERIES BETTER PARTS BETTER PROFITS The Company As a total supplier for sheet metal manufacturing with almost 60 years of experience, Durma understands and recognizes the challenges,

More information

OPERATOR S MANUAL DRILLING MACHINE WITH ELECTROMAGNETIC BASE

OPERATOR S MANUAL DRILLING MACHINE WITH ELECTROMAGNETIC BASE OPERATOR S MANUAL DRILLING MACHINE WITH ELECTROMAGNETIC BASE UNIT 30 NEWHALLHEY BUSINESS PARK, NEWHALLHEY RD, RAWTENSTALL, ROSSENDALE, LANCASHIRE BB4 6HR Tel. +44 1706 229490, fax. +44 1706 830496 www.jeiuk.com

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

SERIES 100 VOLUMERIK VOLUMETRIC DRY FEEDER OPERATING AND MAINTENANCE INSTRUCTIONS

SERIES 100 VOLUMERIK VOLUMETRIC DRY FEEDER OPERATING AND MAINTENANCE INSTRUCTIONS SERIES 100 VOLUMERIK VOLUMETRIC DRY FEEDER OPERATING AND MAINTENANCE INSTRUCTIONS Merrick Industries, Inc. 10 Arthur Drive Lynn Haven, FL 32444 850-265-3611 www.merrick-inc.com 1 2 TABLE OF CONTENTS 1.0

More information

MICROSCANNER TM D-Series

MICROSCANNER TM D-Series MICROSCANNER TM D-Series High Performance Models I N S T R U C T I O N M A N U A L C O R P O R A T I O N 818098 400 Pleasant Street Watertown, MA 02472 (617) 923-9900 800-442-3006 FAX: 617-923-9911 C O

More information

Manual Electric resistance tester PCE-MO 2001

Manual Electric resistance tester PCE-MO 2001 www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk

More information

figure 1 figure 2 INSTRUCTIONS AND TIPS FOR THE INSTALLATION OF THE HC MODEL CINEMA MIRROR x = y

figure 1 figure 2 INSTRUCTIONS AND TIPS FOR THE INSTALLATION OF THE HC MODEL CINEMA MIRROR x = y CONSIDERATIONS 1 Cinema Mirror is an active optic set to be installed in false ceilings hiding the projection equipment, and that through a pulsation it opens a floodgate of 335x335 mm., allowing the projection

More information

HVS-1000DN. Digital Micro Vickers Hardness Tester. BMS Bulut Makina Sanayi Ve Ticaret Ltd. Şti.

HVS-1000DN. Digital Micro Vickers Hardness Tester. BMS Bulut Makina Sanayi Ve Ticaret Ltd. Şti. OPERATIONAL MANUAL HVS-1000DN Digital Micro Vickers Hardness Tester BMS Bulut Makina Sanayi Ve Ticaret Ltd. Şti. İkitelli Organize Sanayi Bölgesi Dolapdere Sanayi Sitesi Ada 4 No : 7-9 Başakşehir / İSTANBUL-TURKEY

More information

- Clamshell - OD-Mounted Pipe Cutting and Beveling Machine. Split frame. cutting and beveling simultaneously

- Clamshell - OD-Mounted Pipe Cutting and Beveling Machine. Split frame. cutting and beveling simultaneously Split frame OD-Mounted Pipe Cutting and Beveling Machine The series machine is ideal for all types of pipe cutting, beveling and end preparation. The split frame design allows the machine to split in half

More information

VC835 DIGTAL MULTIMETER Operation Manual

VC835 DIGTAL MULTIMETER Operation Manual VC835 DIGTAL MULTIMETER Operation Manual CONTENTS GENERAL DESCRIPTION Safety Instructions FEATURES OPERATION MAINTENANCE TROUBLE SHOOTING 1. General Description This is a 3 1/2 digital multimeter with

More information

VERTICAL FORM FILL SEAL MACHINES

VERTICAL FORM FILL SEAL MACHINES VERTICAL FORM FILL SEAL MACHINES AUTOMATIC PACKAGING MACHINES 49 Vertical Form, Fill Seal Machines: With over 30 years experience, Audion manufactures a complete line of reliable, flexible, low maintenance,

More information

Operating Manual 6 Industrial Bench Grinder ATBG280/

Operating Manual 6 Industrial Bench Grinder ATBG280/ Operating Manual 6 Industrial Bench Grinder ATBG280/6 804531 40 Year Australian Heritage The reputable name in bench grinders for 40 years Protect yourself and others by observing all safety information,

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only

More information

ASSEMBLY AND INSTALLATION INSTRUCTIONS

ASSEMBLY AND INSTALLATION INSTRUCTIONS T0412 / T0413 ASSEMBLY AND INSTALLATION INSTRUCTIONS WARNING: NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements. 2. READ AND SAVE THESE INSTRUCTIONS. Hardware

More information

DCB-FA 330 DOUBLE COLUMN AUTOMATIC MITER BANDSAW MACHINE

DCB-FA 330 DOUBLE COLUMN AUTOMATIC MITER BANDSAW MACHINE DCB-FA 330 DOUBLE COLUMN AUTOMATIC MITER BANDSAW MACHINE F.255 1 / 10 F.255 2 / 10 METAL CUTTING WITH BANDSAWS Today, Band saws are the easiest, the fastest and the best way to cut metal. They are used

More information

hawos Pegasus 400 Volt

hawos Pegasus 400 Volt hawos kornmühlen GmbH Ober-Eschbacher Straße 37 D - 61352 Bad Homburg v.d.h. Telefon 0 61 72 / 40 12 00 Fax 0 61 72 / 40 12 019 e-mail info@hawos.de Internet www.hawos.de hawos Pegasus 400 Volt Page 2

More information

FUNCTION GENERATOR OPERATION MANUAL

FUNCTION GENERATOR OPERATION MANUAL FUNCTION GENERATOR OPERATION MANUAL INDEX 1. Introduction (3) 2. Specifications (3) 3. Working Theory (7) 4. Structure (8) 5. Operation & Maintenance (9) 6. Accessories (14) 1 This instrument is a highly

More information

ATD AMP Variable Speed Reciprocating Saw Owner s Manual

ATD AMP Variable Speed Reciprocating Saw Owner s Manual ATD-10535 7 AMP Variable Speed Reciprocating Saw Owner s Manual Manufactured in China To ATD Tools, Inc. Specifications TECHNICAL SPECIFICATIONS Voltage: 120V Frequency: 60Hz Power input: 7 Amps No load

More information

Sunlord Wire Wound SMD Power Inductor Page 1 of 7 SPECIFICATIONS

Sunlord Wire Wound SMD Power Inductor Page 1 of 7 SPECIFICATIONS Sunlord Wire Wound SMD Power Inductor Page 1 of 7 SPECIFICATIONS Customer Product Name Wire Wound SMD Power Inductor Sunlord Part Number SWPA4020S T Customer Part Number [ New Released, Revised] SPEC No.:

More information

SUPER MINIATURE PC BOARD TYPE AUTOMOTIVE RELAY

SUPER MINIATURE PC BOARD TYPE AUTOMOTIVE RELAY SUPER MINIATURE PC BOARD TYPE AUTOMOTIVE RELAY CJ RELAYS (ACJ) RoHS compliant FEATURES Smallest in its class, it is extremely compact at approx. 2/3 the size of previous products. Compared to our previous