CLINICAL SCIENCES. The Visual Performance and Metamorphopsia of Patients With Macular Holes

Size: px
Start display at page:

Download "CLINICAL SCIENCES. The Visual Performance and Metamorphopsia of Patients With Macular Holes"

Transcription

1 CLINICAL SCIENCES The Visual Performance and Metamorphopsia of Patients With Macular Holes Yoshihiro Saito, MD; Yoshiko Hirata, MD; Atsushi Hayashi, MD; Takashi Fujikado, MD; Masahito Ohji, MD; Yasuo Tano, MD ackground: Most patients attain better visual acuity with the elimination of metamorphopsia after successful closure of a macular hole (MH) by vitrectomy. Objective: To determine the presurgical visual function of eyes with an MH. Methods: We examined 54 eyes of 51 patients with an idiopathic MH using the Amsler chart. We evaluated the types of subjective metamorphopsia and compared them with the clinical factors associated with MHs. In a prospective study, we performed a montage test on a separate group of 16 patients with unilateral idiopathic MHs. The patients were asked to choose, while viewing with their better eye, the computer-modified picture that best matched the unmodified image seen by the eye with the MH. Results: From the results of the Amsler chart test, we divided the subjective changes into 2 types of metamorphopsia; of the 54 eyes, pincushion distortion (bowed toward the center) was found in 33 (61%), and unpatterned distortion (no specific pattern) was found in 21 (39%). Pincushion distortion was significantly associated with an MH of shorter duration ( 6 months) (P =.03) and an early stage (stage 2) of MH formation (P =.02). A scotoma was hard to detect, and patients had difficulty describing their scotomata and distortions. In the montage test, patients with early MHs chose portraits modified with a pincushion type of distortion. Conclusions: We found concentric pincushion metamorphopsia without subjective scotomata, which we suggest arises from an eccentric displacement of the photoreceptors. This accounts for the main characteristic of the visual performance of patients with idiopathic MHs. Arch Ophthalmol. 2000;118:41-46 From the Departments of Ophthalmology, Osaka University Medical School, Osaka (Drs Saito, Hirata, Hayashi, Fujikado, Ohji, and Tano), and Hyogo Prefectural Nishinomiya Hospital, Nishinomiya (Dr Saito), Japan. KELLY AND Wendel1 and others 2-4 have reported on the effect of the closure of idiopathic macular holes (MHs) on the recovery of visual function after pars plana vitrectomy and gas tamponade. After the successful closure of the holes, many patients gain better visual acuity with the disappearance of the presurgical metamorphopsia. 5-7 However, relatively little attention has been paid to the quality of visual function in the presence of MHs, ie, the presurgical visual function. The visual loss in eyes with a fullthickness MH is thought to be caused by the absence of the neurosensory retina in the area of the anatomical defect and by the reduction of retinal function in the surrounding area of retinal detachment. 8 Preoperative microperimetry with a scanning laser ophthalmoscope has demonstrated an absolute scotoma with a relative scotoma in the surrounding concentric isopters that corresponded to the anatomical defect. 9,10 Histological studies have shown the absence of all retinal layers in the area of the hole. The presence of these alterations would be expected to produce a central absolute scotoma surrounded by an area of metamorphopsia. When we examine the patients subjective symptoms, however, only a few patients have a scotoma and the most consistent complaint is that objects appeared distorted, fragmented, or both (ie, metamorphopsia). One of the methods used to detect functional visual changes is the Amsler chart test. 11,12 It is a rapid and sensitive technique for evaluating 10 of the central visual field in patients with macular changes. 13 Recently, it has been used to detect the early signs of macular changes in the fellow eye of patients with visual loss from age-related macular degeneration. Johnson and Gass 14 conducted Amsler chart testing in patients with MHs and reported that metamorphopsia was the main symptom. In this study, we studied in more detail the visual performance of patients with idiopathic MHs using the Amsler chart. We found that the characteristic central metamorphopsia was a pincushion distortion, 41

2 PATIENTS AND METHODS etween January 9, 1995, and December 19, 1997, we examined 54 eyes of 51 patients with an idiopathic MH using the Amsler chart. The research followed the tenets of the Declaration of Helsinki, informed consent was obtained from all participants, and the research was approved by the Departmental Review oard of Osaka University, Osaka, Japan. There were 16 men and 35 women whose mean ± SD age was 64.3 ± 6.5 years (range, years). Fundus examinations were performed with a double aspheric indirect lens (Super Field; Volk Optical Inc, Mentor, Ohio) or a +78-diopter lens. When there was a question about the MH, microperimetry with a scanning laser ophthalmoscope was used to separate a pseudo-mh from a true full-thickness MH. 10 Using Gass classification, 16 there were 16 eyes with stage 2, 32 eyes with stage 3, and 6 eyes with stage 4 MHs. The duration of the MH, based on the patient s complaint, was 0.2 to 48 months (mean ± SD, 5.0 ± 9.1 months). The preoperative visual acuities ranged from 0.02 to We examined the results of the Amsler tests of the patients retrospectively, and evaluated the type of metamorphopsia. The type of metamorphopsia was compared with the duration of the MH, the stage of the MH, and the preoperative visual acuity. The Amsler chart examinations were carried out by the method recommended by Amsler, 11 with a working distance of 0.3 m and the use of the same spectacle correction as used to test the reading acuity. Statistical analysis was performed using the 2 test or the Fisher exact test. etween January 12, 1998, and December 18, 1998, a separate group of 16 patients with unilateral idiopathic MHs (stage 2, 4 patients; stage 3, 10 patients; and stage 4, 2 patients) was studied to determine the visual perception of patients with an MH. The patients consisted of 4 men and 12 women (mean age, 66 years; range, years). The duration of the MH was less than 6 months. These patients were shown 4 photographs (10 13 cm) of a painting (Leonardo da Vinci s Mona Lisa), an unmodified picture and 3 that had been modified using computer software (Adobe Photoshop; Adobe Systems Inc, San Jose, Calif). While viewing the pictures with their unaffected eye, they were asked to select the portrait that best resembled the unmodified photograph seen by the affected eye. ie, a distortion bowed toward the center of the hole. We suggest that this results from the displacement of the photoreceptors due to the tangential traction by the posterior vitreous. 15 We also allowed patients to view computermodified pictures, and we hypothesized about how the MH affected the visual function of patients. RESULTS From the results of the Amsler chart testing, the metamorphopsia was divided into 2 types. The first type was a pincushion distortion that made lines bowed toward the center (Figure 1, A), and the second was unpatterned metamorphopsia (Figure 1, ) that had no specific pattern. Of the 54 eyes, pincushion distortion was found in 33 (61%) and unpatterned metamorphopsia was found in 21 (39%). The Table shows the clinical features associated with the metamorphopsia as determined by Amsler chart testing. A pincushion distortion was significantly associated with an MH of shorter duration ( 6 months) and with an earlier stage of MH (stage 2). ecause there was metamorphopsia in all of the patients, the central scotoma was usually difficult to delineate. Although most of the patients complained of loss of central vision, a scotoma or the disappearance of the fixation dot was hard to detect. The patients stated that when they gazed a little away from the central dot, it became easier to find the dot. For the montage test, we modified the classic Mona Lisa portrait as follows: unmodified (Figure 2, A), a scotoma in the face (Figure 2, ), a pincushion distortion between the eyebrows (Figure 2, C), and a pincushion distortion with a small central area removed from the left eye (Figure 2, D). When viewed, all of the patients promptly denied seeing a central scotoma in Figure 2,. The patients had difficulty describing their scotomata and distortions precisely; however, all patients selected the pincushion photograph as their perception with the eye with the MH (Figure 2, C and D). The difference in their description was in the location, size, or both of the pincushion lesion in the photographs. Two patients stated that the pincushion area appeared darker than other parts of the photograph. COMMENT Our results indicated that approximately 70% of the patients with a fresh MH (duration, 6 months) have metamorphopsia of the pincushion type. After a comprehensive study of the development of an MH, Gass 15,16 established a classification of MHs, including the enlargement of retinal tissue resulting from a tangential traction of the vitreous. Smith and associates 17 also implied that the enlargement of the MH occurs without tissue loss around the macula. We have obtained evidence supporting the hypothesis by Gass, namely, an enlargement of the MH with displacement of the photoreceptors. Can these observations on patients with an MH tell us anything about the retinal pathological characteristics? Assume a vertical line is imaged on the retina a few degrees from the fovea (Figure 3, A). If the line is to be perceived as bowing inward at the center, ie, a pincushion type of distortion, the center of the line must be closest to the fovea and the eccentric points of the line must fall on retinal points of increasing distance from the vertical meridian (Figure 3, ). For this to happen, the photoreceptors underlying the bowed line must be displaced (Figure 3, C) toward the vertical line shown in Figure 3, A, ie, from A through F to A through F. If this movement of the photoreceptors occurs as by the traction of the retina, the image of the vertical line will fall on photoreceptors that will project the image as if it arose from stimulation of A through F, ie, a curved line bow- 42

3 A Pincushion Unpatterned Figure 1. Plots from the Amsler chart test. A, A pincushion distortion in a patient with an early macular hole., Unpatterned metamorphopsia in a patient with a long-standing macular hole. Characteristics of Metamorphopsia by Amsler Chart Testing and Factors Associated With the MH* Type of Metamorphopsia Pincushion Unpatterned MH Features (n = 33) (n = 21) P Duration, mo Stage Preoperative VA 20/ / *MH indicates macular hole; VA, visual acuity. ing toward the center. This would then imply that the retina would be displaced the most at the center and progressively less in the peripheral portion. This agrees well with the appearance of an MH as observed by indirect ophthalmoscopy. The Amsler chart consists of a grid with vertical and horizontal lines with a fixation dot in the center. If we use a chart with only vertical lines and a fixation dot, we can represent the patient s view (Figure 4). With an MH and the displacement of the retina, the brain s image of straight lines is bent toward the center (the pincushion distortion) and the fixation dot is not seen by the patient with an MH (the central scotoma). This agrees well with the main characteristic of metamorphopsia in patients with an MH as a pincushion distortion with a defect of the central visual field. The central dot in the chart cannot be recognized because of the MH, although most patients can point out the central dot by eccentric fixation. An MH is usually accompanied by a fluid cuff around the hole leading to functional damage to the retina surrounding the MH (Figure 5), and the patient s perception will be more complicated than the anatomical alterations. The reason why some patients with an MH have metamorphopsia without any specific pattern (unpatterned) is probably due to the duration of the MH, namely, there may be more damage to the surrounding macular region with an MH of longer duration. In addition, we must also be aware of suppression in the brain as an adaptation to the metamorphopsia. If one assumes that the foveal cells can also become nonfunctioning in longstanding cases, then there would be a true foveal scotoma, rather than a remapping. Schuchard 18 illustrated that scotomata frequently are filled in perceptually, and patients often report the filling in as distortions similar to the unpatterned distortions described herein. In this case, the distortion might be attributed to an active cortical phenomenon rather than simply an extension of the abnormal retinotopic projection hypothesis. The significant (P =.03) correlation between MH duration and characteristics of metamorphopsia can be caused by these reasons. Thus, patients with an MH of short duration who maintain good photoreceptor function with less adaptation or fill-in phenomenon in the brain are more sensitive to the pincushion distortion as a defect of the central visual field. The enlargement of the hole without tissue loss around the macula, ie, retinal photoreceptor displacement, was also confirmed by Jensen and Larsen 19 using differential perimetry. They reported a discrepancy in the size of the objective and subjective scotoma by differential perimetry using red and green filter glasses. They found that the subjective scotoma was concentric but considerably smaller than the objective scotoma in patients with symptoms for less than 6 months. In patients with a documented duration of symptoms for longer than 2 years, no discrepancy was found between the objective and subjective scotomata. We also investigated the theoretical basis of the Watzke-Allen sign (Figure 6). Patients with a fullthickness MH can describe a complete break in a vertical 43

4 A C D Figure 2. Photographs of a Mona Lisa portrait modified by computer software. A, Normal portrait., Scotoma in a part of the face. C, Pincushion modification between the eyebrows using a pinch filter. D, Pincushion modification with deletion of a small area of the left eye mainly by a pinch filter. The original picture size is cm. For a viewing distance of 0.3 m, the scotoma and pinch-filtered area are approximately 2 and 4, respectively. 44

5 A Retina C A A Fovea Fovea C D C D E E F F Figure 3. A, A straight line projected on the retina., A pincushion-type line imaged on the retina. C, oth lines on the retina. If a straight line is to be seen as a curved line, the retinal points A through F must move to A through F or the photoreceptors must be displaced so that they underlie A through F. When any of the primed letters are stimulated, they will be perceived as originating from A through F retinal points. A Lines and a Dot Projected on the Macular Photoreceptor Normal Macular Hole Lines and a Dot Recognized in the rain Normal Macular Hole Figure 4. Theoretical background of Amsler chart testing for a macular hole. Light dots represent photoreceptors of a normal retina (A) and a retina with a macular hole () that revealed eccentric displacement. The central dot of the chart cannot be recognized because of the macular hole, ie, absence of the retina. A A Straight Line Projected on the Macular Hole Eccentric Movement of the Photoreceptor rain Image of the Straight Line in the Patient Figure 5. A straight line of the Amsler chart projected on the macular hole (A). Theoretically, the brain image of the straight line is bent toward the center (). However, because the retina around the macular hole (black dots) may be damaged functionally, the patient s view will be more complicated. Figure 6. Theoretical basis of Watzke-Allen testing. ecause of the eccentric displacement of the macular photoreceptors, a slit of light oriented perpendicularly and crossing the macular hole is usually reported as thinning of the beam by the brain. light beam, 20 although this sign is not always reliable. Careful questioning of the patient during the testing is important to determine whether a complete break or a thinning of the light beam is being perceived. 21,22 ecause of the eccentric displacement of the macular retina, a slit light beam oriented perpendicularly and centered on the macular lesion is usually perceived as a thinning of the slit light beam by the brain. This phenomenon is another piece of evidence for the displacement of the photoreceptor. We found concentric pincushion metamorphopsia without a subjective scotoma, which we suggest arises from an eccentric displacement of the retina. This accounts for the main characteristics of the visual performance of patients with an idiopathic MH. Accepted for publication July 13, Reprints: Yoshihiro Saito, MD, Department of Ophthalmology, Hyogo Prefectural Nishinomiya Hospital, 13-9 Rokutanji, Nishinomiya , Japan ( ysmd@pop07.odn.ne.jp). REFERENCES 1. Kelly NE, Wendel RT. Vitreous surgery for idiopathic macular holes: results of a pilot study. Arch Ophthalmol. 1991;109: Poliner LS, Tornambe PE. Retinal pigment epitheliopathy after macular hole surgery. Ophthalmology. 1992;99: Glaser M, Michels RG, Kuppermann D, Sjaarda RN, Pena RA. Transforming growth factor- 2 for the treatment of full-thickness macular holes: a prospective randomized study. Ophthalmology. 1992;99: Liggett PE, Skolik SA, Horio, Saito Y, Alfaro DV, Mieler W. Human autologous serum for the treatment of full-thickness macular holes. Ophthalmology. 1995; 102: Maeno T, Hattori T, Ninomiya Y, et al. Visual functional changes in idiopathic macular holes treated by vitrectomy. Nippon Ganka Gakkai Zasshi. 1996;100:

6 6. Liesenhoff O, Messmer EM, Pulur A, Kampik A. Surgical management of complete macular foramina. Ophthalmologe. 1996;93: Matsumura M. Impressions: a patient s view [letter]. Retina. 1998;18: Sjaarda RN, Frank DA, Glaser M, Thompson JT, Murphy RP. Resolution of an absolute scotoma and improvement of relative scotomata after successful macular hole surgery. Am J Ophthalmol. 1993;116: Acosta F, Lashkari K, Raynaud X, Jalkh AE, Van de Velde F, Chedid N. Characterization of functional changes in macular holes and cysts. Ophthalmology. 1991; 98: Tsujikawa M, Ohji M, Fujikado T, et al. Differentiating full thickness macular holes from impending macular holes and macular pseudoholes. r J Ophthalmol. 1997; 81: Amsler M. Quantitative and qualitative vision. Trans Ophthalmol Soc U K. 1949; 69: Amsler M. Earliest symptoms of disease of the macula. r J Ophthalmol. 1953; 37: Walsh AR, Magargal LM, Wright F, Donoso LA. The early natural history of subfoveal neovascular membranes in eyes with age-related macular degeneration. Ann Ophthalmol. 1989;21: Johnson RN, Gass JDM. Idiopathic macular holes: observations, stages of formation, and implication for surgical intervention. Ophthalmology. 1988;95: Gass JDM. Idiopathic senile macular hole: its early stages and pathogenesis. Arch Ophthalmol. 1988;106: Gass JDM. Reappraisal of biomicroscopic classification of stages of development of a macular hole. Am J Ophthalmol. 1995;119: Smith RG, Hardmanlea SJ, Galloway NR. Visual performance in idiopathic macular holes. Eye. 1990;4: Schuchard RA. Validity and interpretation of Amsler grid reports. Arch Ophthalmol. 1993;111: Jensen OM, Larsen M. Objective assessment of photoreceptor displacement and metamorphopsia. Arch Ophthalmol. 1998;116: Watzke RC, Allen L. Subjective slit beam sign for macular diseases. Am J Ophthalmol. 1969;68: Martinez J, Smiddy WE, Kim J, Gass JDM. Differentiating macular holes from macular pseudoholes. Am J Ophthalmol. 1994;117: Smiddy WE, Gass JDM. Masquerades of macular holes. Ophthalmic Surg Lasers. 1995;26: Notice to Authors: Submission of Manuscripts Selected manuscripts submitted to the Archives of Ophthalmology will be submitted for electronic peer review. Please enclose a diskette with your submission containing the following information: File name Make of computer Model number Operating system Word processing program and version number 46

THRESHOLD AMSLER GRID TESTING AND RESERVING POWER OF THE POTIC NERVE by MOUSTAFA KAMAL NASSAR. M.D. MENOFIA UNIVERSITY.

THRESHOLD AMSLER GRID TESTING AND RESERVING POWER OF THE POTIC NERVE by MOUSTAFA KAMAL NASSAR. M.D. MENOFIA UNIVERSITY. THRESHOLD AMSLER GRID TESTING AND RESERVING POWER OF THE POTIC NERVE by MOUSTAFA KAMAL NASSAR. M.D. MENOFIA UNIVERSITY. Since Amsler grid testing was introduced by Dr Marc Amsler on 1947and up till now,

More information

EXAMINATION OF THE CENTRAL VISUAL FIELD AT

EXAMINATION OF THE CENTRAL VISUAL FIELD AT Brit. J. Ophthal. (1968) 52, 408 EXAMINATION OF THE CENTRAL VISUAL FIELD AT A READING DISTANCE*t BY V. N. HIGHMAN Moorfields Eye Hospital, City Road, London THIS investigation was started in an attempt

More information

Introduction. scotoma. Effects of preferred retinal locus placement on text navigation and development of adventageous trained retinal locus

Introduction. scotoma. Effects of preferred retinal locus placement on text navigation and development of adventageous trained retinal locus Effects of preferred retinal locus placement on text navigation and development of adventageous trained retinal locus Gale R. Watson, et al. Journal of Rehabilitration Research & Development 2006 Introduction

More information

Novel 3D Computerized Threshold Amsler Grid Test CA, USA

Novel 3D Computerized Threshold Amsler Grid Test CA, USA Novel 3D Computerized Threshold Amsler Grid Test Wolfgang Fink 1,2 and Alfredo A. Sadun 2 1 California Institute of Technology, Pasadena, CA, USA 2 Doheny Eye Institute, Keck School of Medicine, University

More information

Examination of the ten degrees of visual field surrounding fixation

Examination of the ten degrees of visual field surrounding fixation Examination of the ten degrees of visual field surrounding fixation Michael Wall, M.D. Tulane University School of Medicine NANOS, 1987 Albrecht von Graete :ntroduced visual field testing into clinical

More information

Retinally-induced aniseikonia

Retinally-induced aniseikonia Retinally-induced aniseikonia G.C. de Wit, Ph.D. Optical Diagnostics, Eikvaren 19, 4102 XE Culemborg, The Netherlands Abstract Purpose: To show that retinally-induced aniseikonia may vary as a function

More information

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert University of Groningen Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert IMPORTANT NOTE: You are advised to consult the publisher's

More information

EYE ANATOMY. Multimedia Health Education. Disclaimer

EYE ANATOMY. Multimedia Health Education. Disclaimer Disclaimer This movie is an educational resource only and should not be used to manage your health. The information in this presentation has been intended to help consumers understand the structure and

More information

Conventional photographs do not show how, at any moment of visual fixation, neural

Conventional photographs do not show how, at any moment of visual fixation, neural SPEIAL ARTILE Simulating Vision With and Without Macular Disease David J. Marmor, MFA; Michael F. Marmor, MD onventional photographs do not show how, at any moment of visual fixation, neural vision is

More information

2 The First Steps in Vision

2 The First Steps in Vision 2 The First Steps in Vision 2 The First Steps in Vision A Little Light Physics Eyes That See light Retinal Information Processing Whistling in the Dark: Dark and Light Adaptation The Man Who Could Not

More information

The TRC-NW8F Plus: As a multi-function retinal camera, the TRC- NW8F Plus captures color, red free, fluorescein

The TRC-NW8F Plus: As a multi-function retinal camera, the TRC- NW8F Plus captures color, red free, fluorescein The TRC-NW8F Plus: By Dr. Beth Carlock, OD Medical Writer Color Retinal Imaging, Fundus Auto-Fluorescence with exclusive Spaide* Filters and Optional Fluorescein Angiography in One Single Instrument W

More information

VISUAL PROSTHESIS FOR MACULAR DEGENERATION AND RETINISTIS PIGMENTOSA

VISUAL PROSTHESIS FOR MACULAR DEGENERATION AND RETINISTIS PIGMENTOSA VISUAL PROSTHESIS FOR MACULAR DEGENERATION AND RETINISTIS PIGMENTOSA 1 SHWETA GUPTA, 2 SHASHI KUMAR SINGH, 3 V K DWIVEDI Electronics and Communication Department 1 Dr. K.N. Modi University affiliated to

More information

Photoreceptor Disruption Related to Persistent Submacular Fluid after Successful Scleral Buckle Surgery

Photoreceptor Disruption Related to Persistent Submacular Fluid after Successful Scleral Buckle Surgery pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2011;25(6):380-386 http://dx.doi.org/10.3341/kjo.2011.25.6.380 Original Article Photoreceptor Disruption Related to Persistent Submacular Fluid after

More information

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design. Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design. Multi-color scanning photocoagulation takes on a new look. Integre Pro Scan

More information

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY Automatic functions make examinations short and simple. Perform the examination with only two simple mouse clicks! 1. START

More information

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY Full Auto OCT High specifications in a very compact design Automatic functions make examinations short and simple. Perform

More information

OCULAR MEDIA* PHOTOGRAPHIC RECORDING OF OPACITIES OF THE. development by the control of diabetes, the supply of a deficient hormone

OCULAR MEDIA* PHOTOGRAPHIC RECORDING OF OPACITIES OF THE. development by the control of diabetes, the supply of a deficient hormone Brit. J. Ophthal. (1955) 39, 85. PHOTOGRAPHIC RECORDING OF OPACITIES OF THE OCULAR MEDIA* BY E. F. FINCHAM Institute of Ophthalmology, University of London THE value of photography for recording pathological

More information

Instruments Commonly Used For Examination of the Eye

Instruments Commonly Used For Examination of the Eye Instruments Commonly Used For Examination of the Eye There are many instruments that the eye doctor might use to evaluate the eye and the vision system. This report presents some of the more commonly used

More information

Slide 4 Now we have the same components that we find in our eye. The analogy is made clear in this slide. Slide 5 Important structures in the eye

Slide 4 Now we have the same components that we find in our eye. The analogy is made clear in this slide. Slide 5 Important structures in the eye Vision 1 Slide 2 The obvious analogy for the eye is a camera, and the simplest camera is a pinhole camera: a dark box with light-sensitive film on one side and a pinhole on the other. The image is made

More information

Multifocal Electroretinograms in Normal Subjects

Multifocal Electroretinograms in Normal Subjects Multifocal Electroretinograms in Normal Subjects Akiko Nagatomo, Nobuhisa Nao-i, Futoshi Maruiwa, Mikki Arai and Atsushi Sawada Department of Ophthalmology, Miyazaki Medical College, Miyazaki, Japan Abstract:

More information

Retinopathy From a Green Laser Pointer

Retinopathy From a Green Laser Pointer CLINICAL SCIENCES Retinopathy From a Green Laser Pointer A Clinicopathologic Study Dennis M. Robertson, MD; Jay W. McLaren, PhD; Diva R. Salomao, MD; Thomas P. Link, CRA Objective: To report retinopathy

More information

The Human Brain and Senses: Memory

The Human Brain and Senses: Memory The Human Brain and Senses: Memory Methods of Learning Learning - There are several types of memory, and each is processed in a different part of the brain. Remembering Mirror Writing Today we will be.

More information

Introduction. Chapter Aim of the Thesis

Introduction. Chapter Aim of the Thesis Chapter 1 Introduction 1.1 Aim of the Thesis The main aim of this investigation was to develop a new instrument for measurement of light reflected from the retina in a living human eye. At the start of

More information

Suppression in strabismus

Suppression in strabismus British Journal ofophthalmology, 1984, 68, 174-178 Suppression in strabismus an update J. A. PRATT-JOHNSON AND G. TILLSON From the Department of Ophthalmology, University ofbritish Columbia, Vancouver,

More information

Peripheral Prism Glasses for Hemianopia Giorgi et al. APPENDIX 1

Peripheral Prism Glasses for Hemianopia Giorgi et al. APPENDIX 1 1 Peripheral Prism Glasses for Hemianopia Giorgi et al. APPENDIX 1 Monocular and binocular sector prisms are commonly used for hemianopia.3, 10, 14 The impact of these prisms on the visual field is not

More information

Human Vision and Human-Computer Interaction. Much content from Jeff Johnson, UI Wizards, Inc.

Human Vision and Human-Computer Interaction. Much content from Jeff Johnson, UI Wizards, Inc. Human Vision and Human-Computer Interaction Much content from Jeff Johnson, UI Wizards, Inc. are these guidelines grounded in perceptual psychology and how can we apply them intelligently? Mach bands:

More information

In the following diagram the parts of the eye are visualized and labeled for you.

In the following diagram the parts of the eye are visualized and labeled for you. Investigation 3.12B: The Eye In the preceding case study marker of the problem of greatest concern to you lay in finding the pupils fixed in a dilated position. But what is the pupil and what makes it

More information

Information Guide. Synoptophore (Major Amblyoscope) Heading. Body copy. Body copy bold

Information Guide. Synoptophore (Major Amblyoscope) Heading. Body copy. Body copy bold Information Guide Heading Body copy Body copy bold Synoptophore (Major Amblyoscope) Synoptophore (sin-op-to-phore) Greek: syn = with, ops = eye, phoros = bearing Introduction This information has been

More information

Kinder products for your most precious patients

Kinder products for your most precious patients Kinder products for your most precious patients Keeler kinder products Keeler is a global leader in the supply and design of ophthalmic diagnostic products. Our products are used throughout the world to

More information

A reduction of visual fields during changes in the background image such as while driving a car and looking in the rearview mirror

A reduction of visual fields during changes in the background image such as while driving a car and looking in the rearview mirror Original Contribution Kitasato Med J 2012; 42: 138-142 A reduction of visual fields during changes in the background image such as while driving a car and looking in the rearview mirror Tomoya Handa Department

More information

Physiology of Vision The Eye as a Sense Organ. Rodolfo T. Rafael,M.D. Topics

Physiology of Vision The Eye as a Sense Organ. Rodolfo T. Rafael,M.D. Topics Physiology of Vision The Eye as a Sense Organ Rodolfo T. Rafael,M.D. www.clinicacayanga.dailyhealthupdates.com 1 Topics Perception of Light Perception of Color Visual Fields Perception of Movements of

More information

All-Glass Ophthalmic Lenses

All-Glass Ophthalmic Lenses Glass is better... All imaging components in these condensing lens systems are made entirely from glass - even the contacting element - to ensure maximum image integrity. The glass contact element also

More information

Wide-angle viewing systems (WAVs) are a useful

Wide-angle viewing systems (WAVs) are a useful Choices of Wide-angle Viewing Systems for Modern Vitreoretinal Surgery A semi-quantitative evaluation of the visual angle field and imaging contrast. By Yusuke Oshima, MD Wide-angle viewing systems (WAVs)

More information

DEFECTS OF VISION THROUGH APHAKIC SPECTACLE LENSES*t

DEFECTS OF VISION THROUGH APHAKIC SPECTACLE LENSES*t Brit. J. Ophthal. (1967) 51, 306 DEFECTS OF VISION THROUGH APHAKIC SPECTACLE LENSES*t BY ROBERT C. WELSH Miami, Florida BY the use of a series of scale diagrams an attempt is made to explain the following:

More information

The MoviText method: Efficient pre-optical reading training in persons with central visual field loss

The MoviText method: Efficient pre-optical reading training in persons with central visual field loss Technology and Disability 6 (2004) 211 221 211 IOS Press The MoviText method: Efficient pre-optical reading training in persons with central visual field loss Jögen Gustafsson and Krister Inde Division

More information

Low Vision Assessment Components Job Aid 1

Low Vision Assessment Components Job Aid 1 Low Vision Assessment Components Job Aid 1 Eye Dominance Often called eye dominance, eyedness, or seeing through the eye, is the tendency to prefer visual input a particular eye. It is similar to the laterality

More information

Eyes. Inspection Visual Acuity Visual Fields Pupillary Response Fundoscopic Exam

Eyes. Inspection Visual Acuity Visual Fields Pupillary Response Fundoscopic Exam Eyes Inspection Visual Acuity Visual Fields Pupillary Response Fundoscopic Exam Eye Examination Inspection 11.Inspects external ocular (eye) structures (lids, conjunctiva, iris, cornea, pupils) 12.Gently

More information

Better diagnosis and treatment all-in-one.

Better diagnosis and treatment all-in-one. Accessories Options duct Specifications hs-on control of the slit lamp without disturbing r view of the retina. solid state diode cavity yellow-red configuration: 5 nm 70 nm green-red configuration: 53

More information

The Dysphotopsia Mystery. John J. Bussa, M.D.

The Dysphotopsia Mystery. John J. Bussa, M.D. The Dysphotopsia Mystery John J. Bussa, M.D. Cataract Surgery Cataract Surgery Desirable Traits Foldable Lens Inert (non reactive) with a memory Thin folds tight and goes through a smaller incision

More information

12.1. Human Perception of Light. Perceiving Light

12.1. Human Perception of Light. Perceiving Light 12.1 Human Perception of Light Here is a summary of what you will learn in this section: Focussing of light in your eye is accomplished by the cornea, the lens, and the fluids contained in your eye. Light

More information

Vision. The eye. Image formation. Eye defects & corrective lenses. Visual acuity. Colour vision. Lecture 3.5

Vision. The eye. Image formation. Eye defects & corrective lenses. Visual acuity. Colour vision. Lecture 3.5 Lecture 3.5 Vision The eye Image formation Eye defects & corrective lenses Visual acuity Colour vision Vision http://www.wired.com/wiredscience/2009/04/schizoillusion/ Perception of light--- eye-brain

More information

November 14, 2017 Vision: photoreceptor cells in eye 3 grps of accessory organs 1-eyebrows, eyelids, & eyelashes 2- lacrimal apparatus:

November 14, 2017 Vision: photoreceptor cells in eye 3 grps of accessory organs 1-eyebrows, eyelids, & eyelashes 2- lacrimal apparatus: Vision: photoreceptor cells in eye 3 grps of accessory organs 1-eyebrows, eyelids, & eyelashes eyebrows: protection from debris & sun eyelids: continuation of skin, protection & lubrication eyelashes:

More information

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Seema Somani PhD, Ashley Tuan OD, PhD, and Dimitri Chernyak PhD VISX Incorporated, 3400 Central Express Way, Santa Clara, CA

More information

Optical Perspective of Polycarbonate Material

Optical Perspective of Polycarbonate Material Optical Perspective of Polycarbonate Material JP Wei, Ph. D. November 2011 Introduction Among the materials developed for eyeglasses, polycarbonate is one that has a number of very unique properties and

More information

Aspects of Vision. Senses

Aspects of Vision. Senses Lab is modified from Meehan (1998) and a Science Kit lab 66688 50. Vision is the act of seeing; vision involves the transmission of the physical properties of an object from an object, through the eye,

More information

Submission of Figures to the Japanese Journal of Ophthalmology

Submission of Figures to the Japanese Journal of Ophthalmology Submission of Figures to the Japanese Journal of Ophthalmology 1. All figures should be ready for publication without the need for changes by either the editors or publishers. 2. There should be no text

More information

Visual System I Eye and Retina

Visual System I Eye and Retina Visual System I Eye and Retina Reading: BCP Chapter 9 www.webvision.edu The Visual System The visual system is the part of the NS which enables organisms to process visual details, as well as to perform

More information

THE EYE. People of Asian descent have an EPICANTHIC FOLD in the upper eyelid; no functional difference.

THE EYE. People of Asian descent have an EPICANTHIC FOLD in the upper eyelid; no functional difference. THE EYE The eye is in the orbit of the skull for protection. Within the orbit are 6 extrinsic eye muscles, which move the eye. There are 4 cranial nerves: Optic (II), Occulomotor (III), Trochlear (IV),

More information

Retina. Convergence. Early visual processing: retina & LGN. Visual Photoreptors: rods and cones. Visual Photoreptors: rods and cones.

Retina. Convergence. Early visual processing: retina & LGN. Visual Photoreptors: rods and cones. Visual Photoreptors: rods and cones. Announcements 1 st exam (next Thursday): Multiple choice (about 22), short answer and short essay don t list everything you know for the essay questions Book vs. lectures know bold terms for things that

More information

Going beyond the surface of your retina

Going beyond the surface of your retina Going beyond the surface of your retina OCT-HS100 Optical Coherence Tomography Canon s expertise in optics and innovative technology have resulted in a fantastic 3 μm optical axial resolution for amazing

More information

Reports. \ $mm>-j \ksiiimj

Reports. \ $mm>-j \ksiiimj Reports A scanning slit optical microscope. DAVID M. MAURICE. A transparent tissue is illuminated with a narrow slit of light which is formed by light transmitted down one-half of a microscope objective,

More information

Training Eye Instructions

Training Eye Instructions Training Eye Instructions Using the Direct Ophthalmoscope with the Model Eye The Model Eye uses a single plastic lens in place of the cornea and crystalline lens of the real eye (Fig. 20). The lens is

More information

Financial Disclosure. Acufocus. Presbyopia Surgery. Inlay Concept 8/14/17. Presbyopia Correction: The Holy Grail of Ophthalmology

Financial Disclosure. Acufocus. Presbyopia Surgery. Inlay Concept 8/14/17. Presbyopia Correction: The Holy Grail of Ophthalmology Acufocus Financial Disclosure I have no financial interest in any subject presented Presbyopia Correction: The Holy Grail of Ophthalmology Presbyopia Surgery Inlay Concept First conceived in 1949 by Dr.

More information

Blood Vessel Tree Reconstruction in Retinal OCT Data

Blood Vessel Tree Reconstruction in Retinal OCT Data Blood Vessel Tree Reconstruction in Retinal OCT Data Gazárek J, Kolář R, Jan J, Odstrčilík J, Taševský P Department of Biomedical Engineering, FEEC, Brno University of Technology xgazar03@stud.feec.vutbr.cz

More information

AS Psychology Activity 4

AS Psychology Activity 4 AS Psychology Activity 4 Anatomy of The Eye Light enters the eye and is brought into focus by the cornea and the lens. The fovea is the focal point it is a small depression in the retina, at the back of

More information

ABSTRACT 1. INTRODUCTION

ABSTRACT 1. INTRODUCTION High-resolution retinal imaging: enhancement techniques Mircea Mujat 1*, Ankit Patel 1, Nicusor Iftimia 1, James D. Akula 2, Anne B. Fulton 2, and R. Daniel Ferguson 1 1 Physical Sciences Inc., Andover

More information

MEASUREMENT OF ECCENTRIC FIXATION BY THE

MEASUREMENT OF ECCENTRIC FIXATION BY THE Brit. J. Ophthal. (1959) 43, 461. MEASUREMENT OF ECCENTRIC FIXATION BY THE BJERRUM SCREEN* BY G. BROCKBANK AND R. DOWNEY General Infirmary, Leeds Introduction by G. W. Black andj. Foster.-The forward movement

More information

OCT - Anatomy of a Scan. OCT - Anatomy of a Scan. OCT Imaging. OCT Imaging

OCT - Anatomy of a Scan. OCT - Anatomy of a Scan. OCT Imaging. OCT Imaging OCT - Anatomy of a Scan Timothy J. Bennett, CRA, OCT-C, FOPS Penn State Eye Center Hershey, PA OCT - Anatomy of a Scan A systematic approach to understanding what we see in retinal OCT images including

More information

Vision Science I Exam 1 23 September ) The plot to the right shows the spectrum of a light source. Which of the following sources is this

Vision Science I Exam 1 23 September ) The plot to the right shows the spectrum of a light source. Which of the following sources is this Vision Science I Exam 1 23 September 2016 1) The plot to the right shows the spectrum of a light source. Which of the following sources is this spectrum most likely to be taken from? A) The direct sunlight

More information

Research Article Mass Screening of Vision in the Cinemas and a Maculascope for the Masses: Revival of Haidinger s Brush

Research Article Mass Screening of Vision in the Cinemas and a Maculascope for the Masses: Revival of Haidinger s Brush Advances in Optical Technologies, Article ID 692732, 5 pages http://dx.doi.org/10.1155/2014/692732 Research Article Mass Screening of Vision in the Cinemas and a Maculascope for the Masses: Revival of

More information

Goldmann Visual Field. Humphrey Visual Field 4/25/2017. What s So Special About Special Testing?! Houston, we have a problem.

Goldmann Visual Field. Humphrey Visual Field 4/25/2017. What s So Special About Special Testing?! Houston, we have a problem. What s So Special About Special Testing?! Why can t they get the schedule right? looneytunes.com Houston, we have a problem. Communication is the key. We all assume that the other people in the office

More information

Tracking retinal motion with a scanning laser ophthalmoscope

Tracking retinal motion with a scanning laser ophthalmoscope JRRD Volume 42, Number 3, Pages 373 380 May/June 2005 Journal of Rehabilitation Research & Development Tracking retinal motion with a scanning laser ophthalmoscope Zhiheng Xu, MS; 1 Ronald Schuchard, PhD;

More information

PERIPHERAL VISON PATTERN DETECTION DYNAMIC TEST

PERIPHERAL VISON PATTERN DETECTION DYNAMIC TEST PERIPHERAL VISON PATTERN DETECTION DYNAMIC TEST João P Rodrigues, João D Semedo, Fernando M Melicio Institute Systems and Robotics,Technical University, Av Rovisco Pais 1 TN6.21, Lisbon, Portugal jrodrigues@laseeb.org,

More information

LO - Lab #06 - The Amazing Human Eye

LO - Lab #06 - The Amazing Human Eye LO - Lab #06 - In this lab you will examine and model one of the most amazing optical systems you will ever encounter: the human eye. You might find it helpful to review the anatomy and function of the

More information

USE YOUR PC TO QUICKLY MAP REMAINING VISION AFTER FOVEAL VISION LOSS

USE YOUR PC TO QUICKLY MAP REMAINING VISION AFTER FOVEAL VISION LOSS Use your PC to quickly map remaining vision 307 USE YOUR PC TO QUICKLY MAP REMAINING VISION AFTER FOVEAL VISION LOSS MANFRED MACKEBEN, AUGUST COLENBRANDER and ALEKSANDR GOFEN The Smith-Kettlewell Eye Research

More information

In this issue of the Journal, Oliver and colleagues

In this issue of the Journal, Oliver and colleagues Special Article Refractive Surgery, Optical Aberrations, and Visual Performance Raymond A. Applegate, OD, PhD; Howard C. Howland,PhD In this issue of the Journal, Oliver and colleagues report that photorefractive

More information

Visual Optics. Visual Optics - Introduction

Visual Optics. Visual Optics - Introduction Visual Optics Jim Schwiegerling, PhD Ophthalmology & Optical Sciences University of Arizona Visual Optics - Introduction In this course, the optical principals behind the workings of the eye and visual

More information

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging CLARUS 500 from ZEISS HD ultra-widefield fundus imaging Imaging ultra-wide without compromise. ZEISS CLARUS 500 // INNOVATION MADE BY ZEISS Compromising image quality may leave some pathology unseen. Signs

More information

Long-term follow-up with optical coherence tomography and microperimetry in eyes with metamorphopsia after macula-off retinal detachment repair

Long-term follow-up with optical coherence tomography and microperimetry in eyes with metamorphopsia after macula-off retinal detachment repair (2010) 24, 1808 1813 & 2010 Macmillan Publishers Limited All rights reserved 0950-222X/10 $32.00 www.nature.com/eye CLINICAL STUDY Long-term follow-up with optical coherence tomography and microperimetry

More information

Micropulse Duty Cycle. # of eyes (20 ms) Total spots (200 ms)

Micropulse Duty Cycle. # of eyes (20 ms) Total spots (200 ms) Micropulse Duty Cycle Total spots (2 ms) # of eyes (2 ms) Total spots (2 ms) % 269 44 3 47% 9 4 4 25% 3 5 4 4 5% 2 4 3 5 2% 5 2 NA NA 9% 2 4 6% NA NA 57 2 5% 4 5 6 3 3% 39 5 35 5 # of eyes (2 ms) Supplemental

More information

Posterior capsule opacification (PCO) is the most frequent

Posterior capsule opacification (PCO) is the most frequent Retroillumination versus Reflected-Light Images in the Photographic Assessment of Posterior Capsule Opacification Monica Camparini, Claudio Macaluso, Luca Reggiani, and Giovanni Maraini PURPOSE. To investigate

More information

Author Contact Information: Erik Gross VISX Incorporated 3400 Central Expressway Santa Clara, CA, 95051

Author Contact Information: Erik Gross VISX Incorporated 3400 Central Expressway Santa Clara, CA, 95051 Author Contact Information: Erik Gross VISX Incorporated 3400 Central Expressway Santa Clara, CA, 95051 Telephone: 408-773-7117 Fax: 408-773-7253 Email: erikg@visx.com Improvements in the Calculation and

More information

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging CLARUS 500 from ZEISS HD ultra-widefield fundus imaging Imaging ultra-wide without compromise. ZEISS CLARUS 500 // INNOVATION MADE BY ZEISS Compromising image quality may leave some pathology unseen. Signs

More information

Physics of the Eye *

Physics of the Eye * OpenStax-CNX module: m42482 1 Physics of the Eye * OpenStax This work is produced by OpenStax-CNX and licensed under the Creative Commons Attribution License 3.0 Abstract Explain the image formation by

More information

Fitting Manual Use with kerasofttraining.com

Fitting Manual Use with kerasofttraining.com Fitting Manual Use with Fitting Manual: Contents This fitting manual is best used in conjunction with KeraSoft IC online training. To register, please visit www. 01 Kerasoft IC Design - Outlines the KeraSoft

More information

Nursing Assessment of Visual Acuity and Colour Discrimination

Nursing Assessment of Visual Acuity and Colour Discrimination Nursing Assessment of Visual Acuity and Colour Discrimination Visual impairment is the most significant adverse reaction of ethambutol and may occur in individuals receiving ethambutol for longer than

More information

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)? Wavefront-Guided Optics in Clinic: Financial Disclosures The New Frontier November 4, 2017 Matthew J. Kauffman, OD, FAAO, FSLS STAPLE Program Soft Toric and Presbyopic Lens Education Gas Permeable Lens

More information

PSY 214 Lecture # (09/14/2011) (Introduction to Vision) Dr. Achtman PSY 214. Lecture 4 Topic: Introduction to Vision Chapter 3, pages 44-54

PSY 214 Lecture # (09/14/2011) (Introduction to Vision) Dr. Achtman PSY 214. Lecture 4 Topic: Introduction to Vision Chapter 3, pages 44-54 Corrections: A correction needs to be made to NTCO3 on page 3 under excitatory transmitters. It is possible to excite a neuron without sending information to another neuron. For example, in figure 2.12

More information

PERIMETRY A STANDARD TEST IN OPHTHALMOLOGY

PERIMETRY A STANDARD TEST IN OPHTHALMOLOGY 7 CHAPTER 2 WHAT IS PERIMETRY? INTRODUCTION PERIMETRY A STANDARD TEST IN OPHTHALMOLOGY Perimetry is a standard method used in ophthalmol- It provides a measure of the patient s visual function - performed

More information

Optical Coherence Tomography. RS-3000 Advance / Lite

Optical Coherence Tomography. RS-3000 Advance / Lite Optical Coherence Tomography RS-3000 Advance / Lite 12 mm wide horizontal scan available with the RS-3000 Advance allows detailed observation of the vitreous body, retina, and choroid from the macula to

More information

Reading With a Macular Scofoma

Reading With a Macular Scofoma Reading With a Macular Scofoma //. Retinal Locus For Scanning Text George T. Timberlake, Eli Peli,* Edward A. EssocKf and Reed A. Augliere To elucidate how patients with macular scotomas use residual functional

More information

Visual evoked cortical potential can be used to differentiate between uncorrected refractive error and macular disorders

Visual evoked cortical potential can be used to differentiate between uncorrected refractive error and macular disorders Documenta Ophthalmologica 102: 41 62, 2001. 2001 Kluwer Academic Publishers. Printed in the Netherlands. Visual evoked cortical potential can be used to differentiate between uncorrected refractive error

More information

Department of Ophthalmology, Link oping University, SE Link oping, Sweden Received 2 September 2002; received in revised form 24 January 2003

Department of Ophthalmology, Link oping University, SE Link oping, Sweden Received 2 September 2002; received in revised form 24 January 2003 Vision Research 43 (2003) 1777 1787 www.elsevier.com/locate/visres Patients with AMD and a large absolute central scotoma can be trained successfully to use eccentric viewing, as demonstrated in a scanning

More information

The Confocal Tonal Shift

The Confocal Tonal Shift The Confocal Tonal Shift 17 CASE REPORT Timothy J. Bennett, CRA, OCT-C, FOPS Penn State Hershey Eye Center 500 University Drive, HU19 Hershey, PA 17033 717/531-5516 timbennett@eye-pix.com T Introduction

More information

The Appearance of Images Through a Multifocal IOL ABSTRACT. through a monofocal IOL to the view through a multifocal lens implanted in the other eye

The Appearance of Images Through a Multifocal IOL ABSTRACT. through a monofocal IOL to the view through a multifocal lens implanted in the other eye The Appearance of Images Through a Multifocal IOL ABSTRACT The appearance of images through a multifocal IOL was simulated. Comparing the appearance through a monofocal IOL to the view through a multifocal

More information

A New Method for Estimating Effects of Visual Field Loss in a Panoramic Driving Environment

A New Method for Estimating Effects of Visual Field Loss in a Panoramic Driving Environment University of Iowa Iowa Research Online Driving Assessment Conference 2017 Driving Assessment Conference Jun 27th, 12:00 AM A New Method for Estimating Effects of Visual Field Loss in a Panoramic Driving

More information

Vision Science I Exam 2 31 October 2016

Vision Science I Exam 2 31 October 2016 Vision Science I Exam 2 31 October 2016 1) Mr. Jack O Lantern, pictured here, had an unfortunate accident that has caused brain damage, resulting in unequal pupil sizes. Specifically, the right eye is

More information

Chapter 20 Human Vision

Chapter 20 Human Vision Chapter 20 GOALS When you have mastered the contents of this chapter, you will be able to achieve the following goals: Characterize the physical parameters that are significant in human vision. Visual

More information

V isual restitution training1 2

V isual restitution training1 2 3 EXTENDED REPORT Does visual restitution training change absolute homonymous visual field defects? A fundus controlled study J Reinhard, A Schreiber, U Schiefer, E Kasten, B A Sabel, S Kenkel, R Vonthein,

More information

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information Rediscover quality of life thanks to vision correction with technology from Carl Zeiss Patient Information 5 2 It was really w Vision defects: Light that goes astray For clear vision the eyes, cornea and

More information

Medical imaging has long played a critical role in diagnosing

Medical imaging has long played a critical role in diagnosing Three-Dimensional Optical Coherence Tomography (3D-OCT) Image Enhancement with Segmentation-Free Contour Modeling C-Mode Hiroshi Ishikawa, 1,2 Jongsick Kim, 1,2 Thomas R. Friberg, 1,2 Gadi Wollstein, 1

More information

Treatment of Presbyopia during Crystalline Lens Surgery A Review

Treatment of Presbyopia during Crystalline Lens Surgery A Review Treatment of Presbyopia during Crystalline Lens Surgery A Review Pierre Bouchut Bordeaux Ophthalmic surgeons should treat presbyopia during crystalline lens surgery. Thanks to the quality and advancements

More information

Volume 115(11) November 1997 pp

Volume 115(11) November 1997 pp http:/ /gateway l.ovid.com:80/ovidweb.cgi OPHTHALMOLOGY Copyright 1997 by the American Medical Association. All Rights Reserved. Applicable FARS/DFARS Restrictions Apply to Government Use. American Medical

More information

Vitreous imaging system New method for medical diagnosis

Vitreous imaging system New method for medical diagnosis Vitreous imaging system New method for medical diagnosis Dr. Boucherit Taieb, Privet Laboratory, 12 impasse de Venise, Oran, Algeria Privet Laboratory, Dr. Boucherit Taieb, Oran, Algeria Abstract - The

More information

Scanning Eye Movements in Homonymous Hemianopia Documented by Scanning Laser

Scanning Eye Movements in Homonymous Hemianopia Documented by Scanning Laser Scanning Eye Movements in Homonymous Hemianopia Documented by Scanning Laser Ophthalmoscope Retinal Perimetry. Richard J. Jamara OD, FAAO, Eli Peli MSc, OD, FAAO and Frans Van de Velde MD Department of

More information

Refraction of Light. Refraction of Light

Refraction of Light. Refraction of Light 1 Refraction of Light Activity: Disappearing coin Place an empty cup on the table and drop a penny in it. Look down into the cup so that you can see the coin. Move back away from the cup slowly until the

More information

clip Calculation of the power of an iris lens for distant vision ~~~~~~~~~~~~~~~~~~~~~~t P/L2PIL FLI specification: The Netherlands

clip Calculation of the power of an iris lens for distant vision ~~~~~~~~~~~~~~~~~~~~~~t P/L2PIL FLI specification: The Netherlands Brit. _7. Ophthal. (I973) 57, 735 Calculation of the power of an iris lens for distant vision NI. C. COLENBRANDER Department of Ophthalmology, University of Levden, The Netherlands clip Until now most

More information

SURGICAL ROTATION OF THE EYEBALL*

SURGICAL ROTATION OF THE EYEBALL* Brit. J. Ophthal. (1959) 43, 584. SURGICAL ROTATION OF THE EYEBALL* BY R. RODRfGUEZ BARRIOS, E. MARTfNEZ RECALDE, AND CARLOS AND CIELICA MENDILAHARZU From the British Hospital and Neurological Institute,

More information

OPTO6124 Perception Scott Stevenson

OPTO6124 Perception Scott Stevenson OPTO6124 Perception Scott Stevenson Entoptic Phenomena Vision is supposed to tell us about the world beyond ourselves, but sometimes what we see is caused by the visual apparatus itself. Because they come

More information

Image Database and Preprocessing

Image Database and Preprocessing Chapter 3 Image Database and Preprocessing 3.1 Introduction The digital colour retinal images required for the development of automatic system for maculopathy detection are provided by the Department of

More information