All-Glass Ophthalmic Lenses
|
|
- Mervin Horton
- 6 years ago
- Views:
Transcription
1 Glass is better... All imaging components in these condensing lens systems are made entirely from glass - even the contacting element - to ensure maximum image integrity. The glass contact element also allows for non-fluid applications, alcohol and peroxide cleaning, and long-term durability. Say goodbye to the cracking, crazing and hazing that are typically associated with plastic optics. The glass contact element is an exclusive feature not offered by others. Packaging and Instructions Each lens comes with a leather storage case and approved cleaning instructions. Overview Listing and Equivalency Chart Broadband AR Coating Our exclusive anti-reflective lens coating is specifically designed to minimize ambient reflection, delivering a pristine retinal image! This unique AR formula is optimized for use with all Argon, Diode and YAG laser systems. Part ION Part Number Number ION Lens Name Ocular Instruments Volk 6902xx P-IOV-006 ezview 15D 14D 15D 6789xx P-IOV-002 ezview 20D 20D, MaxField 20D 20D 6827xx P-IOV-002-SS SurgiView 20D Maxac 20D 20D ACS 6903xx P-IOV-014 ezview 22D Triple Two 22D Pan Retinal xx P-IOV-007 ezview 25D 25D 6829xx P-IOV-008 ezview 28D MaxField 28D 28D 6828xx P-IOV-008-SS SurgiView 28D Maxax 28D 28D ACS 6839xx P-IOV-009 ezview 30D 30D 6905xx P-IOV-010 ezview 40D 40D 6840xx P-IOV-005 ezview 60D Ultra Mag 60, MaxField 60D 60D 6790xx P-IOV-004 ezview 78D High Mag 78 78D 6791xx P-IOV-003 ezview 90D Standard 90, MaxField 90 90D 6792xx P-IOV-012 ezview 95 MaxField 66D Super xx P-IOV-011 ezview 115 Osher MaxField 78D SuperField NC 6899xx I P-IOV- 013 ezview 124 SP Ultra View SP 123D SuperPupil XL 6841xx P-IOV-001 ezview 125 MaxField 100D Super VitreoFundus 6794xx P-IOV-019 OmniView 85 Ocular Reichel-Mainster 1X, Ocular Mainster Focal/Grid Area Centralis 6908xx P-IOV-018 OmniView 135 Ocular Mainster Wide Field,Ocular PDT 1.6x PDT Lens,TransEquator 6910xx P-IOV-015 OmniView 137 Ocular Pro Retina 120 PB, Ocular Reichel-Mainster 2X Equator Plus 6909xx P-IOV-017 OmniView 145 QuadrAspheric 6795xx P-IOV-016 OmniView 165 Ocular Mainster PRP 165, Ocualr ProRetina 120 PB, Ocualr Richel - SuperQuad Mainster 2X 6897xx P-IOV-030 DirectView Capsulotomy Abraham & Mendelkorn Capsulotomy/Iridectomy, Peyman Capsulotomy/Iridectomy G Capsulotomy 6898xx P-IOV-031 DirectView Iridotomy Abraham & Mendelkorn Capsulotomy/Iridectomy, Peyman Capsulotomy/Iridectomy G Capsulotomy 6912xx P-IOV-034 DirectView Fundus 1.0 Ocular Fundus Centralis Direct 6895xx P-IOV-045 DirectView Suture Lysis Hoskins, Mandelkorn & Ritch Suture Lysis Blumenkrantz Suture Lysis 6896xx P-IOV-046 DirectView Suture Lysis TS Hoskins, Mandelkorn & Ritch Suture Lysis Blumenkrantz Suture Lysis 6911xx P-IOV-051 DirectView Suture Lysis TS Taper 6913xx P-IOV-021 DirectView 1 Mirror 6842xx P-IOV-070 DirectView 1 Mirror SLT Latina SLT Gonio Volk SLT Lens 6894xx P-IOV-026 DirectView 3 Mirror NF (no Flange) 6796xx P-IOV-025 DirectView 3 Mirror (with Flange) G1-G4 lenses 6915xx P-IOV-029 DirectView 4 Mirror NF (no Flange) 6797xx P-IOV-028 DirectView 4 Mirror (with Flange) Various G1-G4 lenses 6916xx P-IOV-047 SurgiView Direct xx P-IOV-048 SurgiView Direct xx P-IOV-038 SurgiView Direct xx P-IOV-040 SurgiView Direct 1.5 Page Page 1 1
2 BIO Slit Lamp ezview 15D, 20D, 22D, 25D, 28D, 30D and 40D Lenses 6902xx ezview 15D High magnification provided by this 15 diopter lens is well suited for detailed observation of the optic nerve head and macula. 6903xx ezview 22D A mid- range lens which delivers the critical high definition viewing of a 20 diopter coupled with the wide-field viewing of higher diopter lenses. An excellent multi purpose lens! 6789xx ezview 20D Improved design delivers superior image clarity throughout the viewing field. Optimized lens surfaces eliminate optical aberrations. 6829xx ezview 28D Designed for small pupil diagnosis and treatment. Excellent wide-field viewing. Complementary lens : 20D or 22D. 6801xx ezview 25D Ideal for use with patients with smaller palpeblar fissures. Offers median field of view and magnification. 6839xx ezview 30D Excellent for use on patients with small pupils. Deliver s a wide field of view and shorter working distance. 6905xx ezview 40D Specifically designed to deliver the widest field of view of any biomicroscopy lens available. Ultra wide-field viewing. Ideal for pediatric ophthalmoscopy. Spot 6902xx +15 BIO Lenses /x.24x 6789xx +20 BIO Lenses /x.32x 6903xx +22 BIO Lenses /x.37x 6801xx +25 BIO Lenses /x.39x 6829xx +28 BIO Lenses /x.44x 6904xx +30 BIO Lenses /x 0.47x 6905xx +40 BIO Lenses /x.6x 6827xx +20 SurgiView Autoclaveable /x.32x 6828xx +28 SurgiView Autoclaveable /x.44x Steam Sterilizable SurgiView 20D & 28D SurgiView lenses are composed entirely of instrument quality glass - there is no plastic to fog, haze or crack during everyday working conditions. The lens has a TRUE steam sterilizable coating which doesn t require complex care instruction. Autoclaveable! What is unique about ION s 6827xx SurgiView 20D & 6828xx SurgiView 28D BIO Lenses is that they are the only surgical BIO lenses designed exclusively with an AR coating that is Autoclave-Safe. Ion has developed this new coating after a decade of research. It is an amazing coating that is a steam sterilizable. The result is an Anti-Reflective Coating which does not require complex care instructions by the Operating Room staff and it really works! Others do not offer coated sterilizable lenses for the O.R. Most others only offer uncoated lenses which cause excessive glare and accumulate water deposits when sterilized. SurgiView BIO lenses are recommended for use by hospitals, clinics and ambulatory surgery centers having ophthalmology surgical services. Page Page 2 2
3 Non-Contact Slit Lamp Lenses 6840xx ezview 60D The high-magnification offered by the 60D is ideal for detailed observation of the posterior pole. Superior stereoscopic properties. Unique anti-reflective lens coating is optimized for use with all Argon, Diode and Yag laser systems. 6790xx ezview 78D Ideal general diagnostic and laser treatment lens. Unique anti-reflective lens coating is optimized for use with all Argon, Diode and Yag laser systems. range of 97 and 1.08x Spot Magnification. 6791xx ezview 90D The standard slit lamp biomicroscopy lens. This 90D design delivers superior clarity, stereopsis and outstanding small pupil capabilities. Compare to other 90D s and see the difference. Advanced Non-Contact Slit Lamp Lenses 6793xx ezview 115 High-index glass and a superior optical design for diagnostic and treatment capabilities that exceed competitive designs. This lens is used in lieu of the 90 diopter for wider field viewing. The lens also permits increased corneal working distance. 6899xx ezview 124SP Perfect for the difficult to dilate patient. You ll achieve an excellent view of the fundus through pupils as small as 3mm. 6792xx ezview 95 Achieve the high magnification viewing of a 60 diopter lens with the wide-field imaging of a 90 diopter! Superior stereoscopic design. Helps identify macular edema, gross detachments, choroidal neovascular membranes, and macular abnormalities. 6841xx ezview 125 An excellent general use slit lamp lens. Ideal balance of high magnification viewing and small pupil capability. ezview 124SP has excellent optical quality for viewing the retina and vitreous, especially in a small pupil. Usually this kind of lens is difficult to use because it can collect moisture easily, but on ezview 124SP it is very difficult to collect that moisture. This lens is one of the best non-contact fundus lenses through a non-dilated pupil! - AKIRA NEGI, M.D. Professor & Chairman Department of Ophthalmology Kobe University Graduate School of Medicine Spot 6840xx +60 Non-contact Slit lamp Lens x 0.87x 6790xx +78 Non-contact Slit lamp Lens x 1.08x 6791xx +90 Non-contact Slit lamp Lens x 1.32x 6792xx +95 Non-contact Slit lamp Lens x 1.0x 6793xx 115 Non-contact Slit lamp Lens x 1.3x 6841xx 125 Non-contact Slit lamp Lens x 1.3x 6899xx 124SP Non-contact Slit lamp Lens x 1.3x Page Page 3 3
4 Contact Slit Lamp Lenses 6908xx OmniView 135 Designed to deliver the ideal laser spot 6794xx OmniView 85 Ultra-high magnification viewing of the posterior pole. Perfect for focal laser treatment of central retinal conditions. 6910xx OmniView 137 Ideal for use on difficult to dilate patients at the slit lamp. This lens delivers an outstanding retinal view through pupils as small as 3mm. size for photodynamic therapy procedures. Provides excellent visualization of the choroidal neovascular membrane. Also well suited for grid laser therapy. 6909xx OmniView 145 Ideal for wide--field observation and treatment of the retina. Great balance of magnification and field of view. 6795xx OmniView 165 Ultra wide-field imaging to the Oraserrata. Provides an incredibly clear view of the retina from the posterior pole to the periphery without the need of shifting or tilting the lens. Perfect for PRP. Spot 6794xx 85 Contact Slit lamp Lens x 0.94x 6908xx 135 Contact Slit lamp Lens x 1.5x 6910xx 137 Contact Slit lamp Lens x 2.27x 6909xx 145 Contact Slit lamp Lens x 1.97x 6795xx 165 Contact Slit lamp Lens x 2.0x Page Page 4 4
5 Single Mirror Lenses Gonioscopy Mirror Lenses 6913xx 1 Mirror Flange This single element ALL GLASS lens has an offset top convex surface that places the image and laser application precisely over the viewing mirror and application area. Flanged 14.5mm contact surface is ideal for laser treatment. No fluid design due to ALL GLASS contacting element. NOTE: Aluminum based mirrored lenses should not be used with SLT lasers. 6894xx 3 Mirror No Flange 3 mirror lenses are of a traditional design, incorporating 3 mirrors angled at 60, 66 and mm contacting surface facilitates dynamic compression technique. Magnification and laser spot magnification factor is 1.0x. 6796xx 3 Mirror with Flange Traditional design, incorporating 3 mirrors angled at 60, 66 and 78. Useful for central and peripheral fundus plus anterior chamber viewing and posterior pole. The 14.5 mm contacting surface facilitates dynamic compression technique. Magnification and laser spot magnification factor is 1.0x. No fluid design due to ALL GLASS contacting element. 6842xx 1 Mirror SLT This single element, ALL GLASS lens has been developed specifically for angle examinations and Selective Trabeculoplasty (SLT) procedures. The DirectView 1 Mirror SLT Lens has an offset top convex surface that places the image and laser application precisely over the internal reflection viewing mirror. The 13.5 mm contact surface. comes with Broadband Anti- Reflective coating and no fluid design. Note: Although designed for the SLT procedure, this 1 Mirror lens is also recommended for all other trabeculoplasty procedures. 6915xx 4 Mirror No Flange Perfect for fast and effective anterior segment examinations! Four 64 offer complete 360 view with minor rotation. 8mm ALL GLASS no fluid surface diameter. Magnification is.9x. spot magnification factor is 1.1x. 6797xx 4 Mirror with Flange Perfect for fast and effective anterior segment examinations! Four 64 mirror angles offer complete 360 view with slight rotation. Magnification is.9x. spot magnification factor is 1.1x. Flanged 14.5 mm contact surface ideal for laser treatment. Exclusive no fluid design with ALL GLASS contacting element. Flange or No Flange? The No-Flange designs actually have less contacting area on the cornea than the traditional types. It is easier, and quicker, to present onto the patient s cornea after applying a topical anesthetic to the patient s eye. The eye-care professional simply places the lens onto the eye and performs the diagnostic/screening exam. The NF is quicker and easier than the traditional flanged types. The Flange types are the traditional design that has been in use for decades. The design with flange has more area of contact onto the patient s cornea and presents a solid platform on the patient s eye with greater stability and gripping effect on the cornea. The Flanged and No-Flange types may be used for diagnostic purposes, while the flanged type is preferred for laser treatment due to the stability factor. The optics of each are exactly the same for both versions and both include ION s optimized Diagnostic/ Broadband Anti-Reflection (A/R) coating. Both require the use of an anesthetic. Mirror Angles Spot 6913xx 1.5x DirectView 1 Mirror x 1.0x 6914xx 1.5x DirectView 1 Mirror SLT x 1.0x 6894xx 3 Mirror DirectView 3 Mirror (No Flange) 60 /66 /78 1.0x 1.0x 6796xx 3 Mirror DirectView 3 Mirror (with Flange) 60 /66 /78 1.0x 1.0x 6915xx 4 Mirror 4 Mirror Gonioscopy Lens (No Flange) 4x64.9x 1.1x 6797xx 4 Mirror 4 Mirror Gonioscopy Lens (with Flange) 4x64.9x 1.1x Page Page 5 5
6 Direct Imaging Lenses No fog. No mess. No kidding. These superior gonioscopy and direct imaging lenses are composed entirely of instrument quality glass - there is no plastic to fog, haze or crack during everyday working conditions. All no flange gonioscopy and direct imaging lenses are composed of a single glass element providing a stable, durable lens design. You can use these advanced lenses with or without fluid! These lenses come standard with an advanced broadband coating. 6897xx DirectView Capsulotomy Promotes precise laser placement on the capsular bag. 6898xx DirectView Iridectomy/Iridotomy Provides an ideal combination of magnification and laser spot magnification for iridectomy and iridotomy procedures. Stable lens design. 6912xx DirectView Fundus 1.0 Designed for superior high magnification viewing and treatment of the optic nerve head and macula. 6895xx DirectView Suture Lysis Designed for laser suture lysis after anterior segment surgery. Large contact surface compresses conjunctival blood vessels and provides a clear view of the sutures as well as enables dynamic rotation of the lens for precise laser placement. 6896xx DirectView Suture Lysis TS This design features a precision compression tip that enable you to cut sutures that were inaccessible with prior suture lysis lens designs. Highly stable design with superior magnification. Part Type Spot 6897xx DirectView Capsulotomy not applicable 1.6x.63x 6898xx DirectView Iridotomy not applicable 1.57x.66x 6912xx DirectView Fundus x 1.0x 6895xx DirectView Suture Lysis x 1.0x 6896xx DirectView Suture Lysis TS not applicable 1.25x 1.0x 6911xx DirectView Suture Lysis TS Taper not applicable Page Page 6 6
7 Surgical Lenses SurgiView Direct Imaging Vitrectomy Lenses These advanced, ALL GLASS vitrectomy lenses are designed to fit a standard vitrectomy ring or lens handle. The first TRUE durable, autoclavable lens coating available for safe, repeated steam sterilization combines the attributes of our superior broadband AR coating to reduce reflection and glare. 6916xx SurgiView Direct.5 Wide-field direct imaging biconcave vitrectomy lens that delivers a wide 48 view of the posterior pole during surgery. 6917xx SurgiView Direct.75 Median-field direct imaging biconcave vitrectomy lens. 6918xx SurgiView Direct 1.0 High-magnfication direct imaging plano vitrectomy lens. 6919xx SurgiView 1.5 Ultra-high-magnfication direct imaging vitrectomy lens. Large imaging plane, lens is oversized at the top - yet still fits in any standard vitrectomy ring or holding handle. Made of high-index glass for peak performance. Spot 6916xx SurgiView Direct x 6917xx SurgiView Direct xx SurgiView Direct x 6919xx SurgiView Direct x 6827xx +20 SurgiView Autoclaveable /x.32x 6828xx +28 SurgiView Autoclaveable /x.44x Steam Sterilizable SurgiView 20D & 28D Until now, you ve been promised Autoclave-safe lenses only to receive specialized cleaning instructions and uncoated special glass lenses that accumulate water deposits and cause excessive glare in the operating room. No More! Finally, there is a real choice. These SugiView lenses employ an amazing coating which is TRUE steam sterilizable. They do not require complex care instructions and it really works. 6827xx SurgiView 20D Composed entirely of instrument quality glass - there is no plastic to fog, haze or crack. Provides the most popular combination of magnification and field of view in the operating room. 6828xx SurgiView 28D Complements the 20D SurgiView lens when patient exhibits small pupil needing diagnosis and treatment in the operating room. Page Page 7 7
ion VISion, Inc. All-Glass Optical Lenses
ion VISion, Inc. Some items in this catalogue may not be available in Canada as they may not be licensed for sale by Health Canada. All-Glass Optical Lenses 1-800-263-3557 About ion VISion Since 2003,
More informationOcular Instruments. Beauty is in the beholder of the eye
Ocular Instruments P r o d u c t C a t a l o g Beauty is in the beholder of the eye Vision It is both our business and our guiding principle. For over 40 years we have stayed focused on a single ideal:
More informationOCULAR INSTRUMENTS. Beauty is in the beholder of the eye
OCULAR INSTRUMENTS P R O D U C T C A T A L O G Beauty is in the beholder of the eye Vision It is both our business and our guiding principle. For over 40 years we have stayed focused on a single ideal:
More informationLatest Product Releases
Latest Product Releases Max360 Series Max360 Three Mirror Universal Max360 Magna View Latina 1X Indexing PSLT Latina 5 Bar Indexing SLT Hwang-Latina 5.0 Indexing SLT Hill Open Access Surgical Gonio Upright
More informationDIAGNOSTIC SKILLS AND TECHNIQUES
Injectable Medications in Ocular Care, Page 85 March 15, 2017 www.reviewofoptometry.com DIAGNOSTIC SKILLS AND TECHNIQUES This new, noninvasive technology is giving a more detailed view of the retinal vasculature
More informationVision. Our personal focus, however, has always been clearly on you. We are not just driven. We are customer driven.
Vision It is both our business and our guiding principle. For over 40 years we have stayed focused on a single ideal: to create and produce ophthalmic lenses of unparalleled sharpness and clarity. And
More informationThe Finest Ophthalmic Imaging
the leader in aspheric optics A HALMA COMPANY The Finest Ophthalmic Imaging [catalog] OCT 2017 How to Contact Volk See the Difference All lenses are not the same; different lenses will not deliver the
More informationThe Finest Ophthalmic Imaging
the leader in aspheric optics A HALMA COMPANY The Finest Ophthalmic Imaging [catalog] How to Contact Volk See the Difference All lenses are not the same; different lenses will not deliver the same image
More informationQuality Optics and Performance to Last a Lifetime TM
Quality Optics and Performance to Last a Lifetime TM Indirect BIO Lenses Classic Slit Lamp Lenses Super Series Slit Lamp Lenses Digital Series Slit Lamp Lenses Indirect Contact Lenses Direct Contact Lenses
More informationCONTACT LENSES Discover a different world
CONTACT LENSES Discover a different world Tradition and innovation Since 1858, visionary thinking and a fascination with technology have guided us to develop innovative products of outstanding reliability:
More information8 ) 7. the volk promise. advisory panel. how to contact volk. 30 day money back guarantee
the volk promise Volk is known worldwide as the premier designer and manufacturer of precision diagnostic and laser lenses. For over a quarter of a century, our goal has been to provide ophthalmologists
More informationIntegre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.
Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design. Multi-color scanning photocoagulation takes on a new look. Integre Pro Scan
More informationEXCHANGE. Financial Disclosure. Clinical pearls In advanced anterior segment surgery being able to do a IOL exchange is a must. Why Do an Exchange
Financial Disclosure D. Ayres, MD Cornea Service IOLBrandon Wills Eye Hospital EXCHANGE Alcon Allergan AMO Bausch and Lomb TearScience BioTissue Why Do an Exchange Refractive surprise after cataract surgery
More informationInstruments Commonly Used For Examination of the Eye
Instruments Commonly Used For Examination of the Eye There are many instruments that the eye doctor might use to evaluate the eye and the vision system. This report presents some of the more commonly used
More informationHEINE Direct Ophthalmoscopes
[ 036 ] 02 HEINE Direct Ophthalmoscopes BETA 200 S BETA 200 / BETA 200 M2 Opt. 1 Opt. 2 K 180 Opt. 1 Opt. 2 mini 3000 mini 3000 LED Optical System Aspherical Conventional Illumination LED-Illumination
More informationThe Dysphotopsia Mystery. John J. Bussa, M.D.
The Dysphotopsia Mystery John J. Bussa, M.D. Cataract Surgery Cataract Surgery Desirable Traits Foldable Lens Inert (non reactive) with a memory Thin folds tight and goes through a smaller incision
More informationHEINE Direct Ophthalmoscopes
[ 040 ] 05 0 [ 02 ] [ 01 ] [ 03 ] [ 04 ] [ 05 ] [ 05 ] Patented 1) Aspherical Optical System (AOS) exclusively from HEINE eliminates corneal and iris relexes to provide large, crisp and glare-free fundus
More informationBasic Principles of the Surgical Microscope. by Charles L. Crain
Basic Principles of the Surgical Microscope by Charles L. Crain 2006 Charles L. Crain; All Rights Reserved Table of Contents 1. Basic Definition...3 2. Magnification...3 2.1. Illumination/Magnification...3
More informationHEINE BETA 200S Ophthalmoscope
[ 033 ] HEINE BETA 200S Ophthalmoscope Superior aspherical optics and 74 single-diopter steps :- Unique optical system. HEINE optimizes the Gullstrand principle with aspherical optics (separation of illumination
More informationHEINE QUALITY. :- HEINE Hand-held Ophthalmic Instruments
HEINE QUALITY M A D E I N G E R M A N Y :- HEINE Hand-held Ophthalmic Instruments :- HEINE HSL150 Hand-held Slit Lamp Uncompromisingly compact. HEINE QUALITY M A D E I N G E R M A N Y 003 [ HEINE HSL150
More informationSurgical Tips for the Beginning Vitreoretinal Fellow: How to Get the Best View During Surgery
Section Editor: Francis Char DeCroos, MD; Adam Gerstenblith, MD; and Rajiv Shah, MD Surgical Tips for the Beginning Vitreoretinal Fellow: How to Get the Best View During Surgery An interview with Andre
More informationWhat s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina
What s Fundus photography s purpose? To document the retina Photographers role to show the retina Document other ocular structures Why do we take them? Why do we do it? We as photographers help the MD
More informationContact lenses Goldmann/Diagnostics/Laser
SVENSKA NEDERLANDS PORTUGUÊS ESPAÑOL ITALIANO FRANÇAIS DEUTSCH ENGLISH INSTRUCTIONS FOR USE Contact lenses Goldmann/Diagnostics/Laser 12. Edition / 2018 04 HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc.
More informationTraining Eye Instructions
Training Eye Instructions Using the Direct Ophthalmoscope with the Model Eye The Model Eye uses a single plastic lens in place of the cornea and crystalline lens of the real eye (Fig. 20). The lens is
More informationLecture 2 Slit lamp Biomicroscope
Lecture 2 Slit lamp Biomicroscope 1 Slit lamp is an instrument which allows magnified inspection of interior aspect of patient s eyes Features Illumination system Magnification via binocular microscope
More informationGonioscopy Wet-Lab. About Me. About Me Gonioscopy. Indications for Gonioscopy. Billing Gonioscopy 12/13/2012. Code: 92020
About Me Gonioscopy Wet-Lab Marcus Gonzales, OD, FAAO Cedar Springs Eye Clinic (formerly BridgeBuilders Eye Clinic) About Me Gonioscopy Evaluates the anterior chamber angle responsible for the outflow
More informationRetinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert
University of Groningen Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert IMPORTANT NOTE: You are advised to consult the publisher's
More informationBetter diagnosis and treatment all-in-one.
Accessories Options duct Specifications hs-on control of the slit lamp without disturbing r view of the retina. solid state diode cavity yellow-red configuration: 5 nm 70 nm green-red configuration: 53
More informationKeeler Direct Ophthalmoscopes
Keeler Direct Ophthalmoscopes Direct Ophthalmoscopes Introduction Direct Ophthalmoscopes A combination of optical perfection, superb ergonomics and versatile features make Keeler direct ophthalmoscopes
More informationCLARUS 500 from ZEISS HD ultra-widefield fundus imaging
CLARUS 500 from ZEISS HD ultra-widefield fundus imaging Imaging ultra-wide without compromise. ZEISS CLARUS 500 // INNOVATION MADE BY ZEISS Compromising image quality may leave some pathology unseen. Signs
More informationCLARUS 500 from ZEISS HD ultra-widefield fundus imaging
CLARUS 500 from ZEISS HD ultra-widefield fundus imaging Imaging ultra-wide without compromise. ZEISS CLARUS 500 // INNOVATION MADE BY ZEISS Compromising image quality may leave some pathology unseen. Signs
More informationHEINE Direct Ophthalmoscopes
[ 036 ] 02 DIRECT OPHTHALMOSCOPES HEINE Direct Ophthalmoscopes BETA 200 S BETA 200 BETA 200 M2 K 180 mini 3000 Opt. 1 Opt. 2 Opt. 1 Opt. 2 Optical System Aspherical Conventional Illumination illumination
More informationWide Angle Ophthalmoscope Instructions
Wide Angle Ophthalmoscope Instructions PLEASE READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY Contents 1. Symbols 2. Warnings & Cautions 3. Description of Product 4. Getting Started 5. Apertures & Filters
More informationPage 1
Rebecca Johnson, CPOT, COT, COE My glasses fog and I have to clean them too often. Frame Adjust tilt or increase vertex distance. If the frame is rubbing against the cheeks or eyebrows, consider a smaller
More informationWhitepaper. DIGITALLY ASSISTED VITREORETINAL SURGERY: A NEW PERSPECTIVE March 2018
Whitepaper DIGITALLY ASSISTED VITREORETINAL SURGERY: A NEW PERSPECTIVE March 2018 Intra-operative Vitreoretinal Visualization Vitreoretinal surgical procedures address eye disorders involving the vitreous
More informationEYE STRUCTURE AND FUNCTION
Name: Class: Date: EYE STRUCTURE AND FUNCTION The eye is the body s organ of sight. It gathers light from the environment and forms an image on specialized nerve cells on the retina. Vision occurs when
More informationThe Eye. Nakhleh Abu-Yaghi, M.B.B.S Ophthalmology Division
The Eye Nakhleh Abu-Yaghi, M.B.B.S Ophthalmology Division Coats of the Eyeball 1- OUTER FIBROUS COAT is made up of : Posterior opaque part 2-THE SCLERA the dense white part 1- THE CORNEA the anterior
More informationTHE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.
XtraFocus THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES. CONTENT Based on the well-established principle of pinhole optics, this intraocular implant represents an innovative alternative for the
More informationGreen Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500
Green Scan Laser PhotocoagulatorGYC-500 Vixi Green Laser PhotocoagulatorGYC-500 The Small, Incredibly Versatile Green Laser Photocoagulator The GYC-500 Vixi / GYC-500 is a solid state green laser that
More informationClinical Evaluation 3-month Follow-up Report
Clinical Evaluation 3-month Follow-up Report Of SeeLens HP Intraocular Lens 27 December 2010 version 1.1 1of 16 Table of Contents TABLE OF CONTENTS... 1 OBJECTIVES... 2 EFFICACY AND SAFETY ASSESSMENTS...
More informationWide-angle viewing systems (WAVs) are a useful
Choices of Wide-angle Viewing Systems for Modern Vitreoretinal Surgery A semi-quantitative evaluation of the visual angle field and imaging contrast. By Yusuke Oshima, MD Wide-angle viewing systems (WAVs)
More informationEyes. Inspection Visual Acuity Visual Fields Pupillary Response Fundoscopic Exam
Eyes Inspection Visual Acuity Visual Fields Pupillary Response Fundoscopic Exam Eye Examination Inspection 11.Inspects external ocular (eye) structures (lids, conjunctiva, iris, cornea, pupils) 12.Gently
More informationNovember 14, 2017 Vision: photoreceptor cells in eye 3 grps of accessory organs 1-eyebrows, eyelids, & eyelashes 2- lacrimal apparatus:
Vision: photoreceptor cells in eye 3 grps of accessory organs 1-eyebrows, eyelids, & eyelashes eyebrows: protection from debris & sun eyelids: continuation of skin, protection & lubrication eyelashes:
More informationVISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser
VISULAS Trion Treatment flexibility to the power of three Multicolor Photocoagulation Laser Carl Zeiss: A pioneer in retinal therapy For many years, Carl Zeiss has fostered a culture of highest precision,
More informationMedical Photonics Lecture 1.2 Optical Engineering
Medical Photonics Lecture 1.2 Optical Engineering Lecture 10: Instruments III 2018-01-18 Michael Kempe Winter term 2017 www.iap.uni-jena.de 2 Contents No Subject Ref Detailed Content 1 Introduction Gross
More informationGoing beyond the surface of your retina
Going beyond the surface of your retina OCT-HS100 Optical Coherence Tomography Canon s expertise in optics and innovative technology have resulted in a fantastic 3 μm optical axial resolution for amazing
More informationKinder products for your most precious patients
Kinder products for your most precious patients Keeler kinder products Keeler is a global leader in the supply and design of ophthalmic diagnostic products. Our products are used throughout the world to
More informationUnderstanding your Direct Ophthalmoscope
Instrument Scan Digvijay Singh, Rohit Saxena, Pradeep Sharma, Vimla Menon Dr. R.P. Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India The direct ophthalmoscope is
More informationContact glasses & magnifying glasses Goldmann/Diagnostics/Laser
SVENSKA NEDERLANDS PORTUGUÊS ESPAÑOL ITALIANO FRANÇAIS DEUTSCH ENGLISH INSTRUCTIONS FOR USE Contact glasses & magnifying glasses Goldmann/Diagnostics/Laser 11. Edition / 2017 06 HAAG-STREIT AG, 3098 Koeniz,
More informationHealth Science 1110 Module 9 Sensations LAB 9. View the Film on Cornea Transplant and answer the questions on your laboratory worksheet.
Health Science 1110 Module 9 Sensations LAB 9 View the Film on Cornea Transplant and answer the questions on your laboratory worksheet. Webpage Activities o Open Internet Explorer o Go to the Health Sciences
More informationFREE DELIVERY. Exclusive & unbeatable prices for optometry students & pre reg optometrists worldwide. OCULUS TRIAL FRAMES See pages 3-7
OCULUS TRIAL FRAMES See pages 3-7 Exclusive & unbeatable prices for optometry students & pre reg optometrists worldwide VOLKS See pages 8-13 QUALITY MUG & PEN 2018-2019 With all orders over 75 DELIVERY
More informationMultifocal and Accommodative
What is an IOL? An intraocular lens (or IOL) is a tiny, artificial lens for the eye. It replaces the eye's natural lens. Retina Cornea Lens Macula The eye's normally clear lens bends (refracts) light rays
More informationGreen Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500
Green Scan Laser PhotocoagulatorGYC-500 Vixi Green Laser PhotocoagulatorGYC-500 The Small, Incredibly Versatile Green Laser Photocoagulator The GYC-500 Vixi / GYC-500 is a solid state green laser that
More information*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most
Simulated vision. Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most The aspheric design of the AcrySof IQ IOL results in improved clarity and image quality. The
More informationGoing beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY
Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY Automatic functions make examinations short and simple. Perform the examination with only two simple mouse clicks! 1. START
More informationGoing beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY
Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY Full Auto OCT High specifications in a very compact design Automatic functions make examinations short and simple. Perform
More informationBeautifully Crafted Slit Lamps.
Beautifully Crafted Slit Lamps www.keeler-symphony.com Painstakingly crafted Slit Lamps Introducing 40H from Keeler quality design and leading technology Slit Lamps with a contemporary design. It s very
More informationHeadline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance
Headline SL 130 Slit Lamp Subline Maximum quality for optimum performance Versatility is the outstanding feature of the SL 130 slit lamp from Carl Zeiss. Combined with an advanced, user-focused operating
More informationSoftware User Manual Slitlamp Adapted OCT SL SCAN-1. PC Software Edition v.3.6.2
Software User Manual Slitlamp Adapted OCT SL SCAN-1 PC Software Edition v.3.6.2 CONTENTS 1 INTRODUCTION...2 1.1 Introduction...2 1.2 Purpose of this Manual...2 1.3 Intended Use...2 1.4 Escape Clauses...3
More informationEYE ANATOMY. Multimedia Health Education. Disclaimer
Disclaimer This movie is an educational resource only and should not be used to manage your health. The information in this presentation has been intended to help consumers understand the structure and
More informationMAKING SENSE OF SLIT LAMP SERVICING
MAKING SENSE OF SLIT LAMP SERVICING HOW TO LOOK AFTER AND CARE FOR A SLIT LAMP The slit lamp is an essential and oftenused diagnostic instrument in ophthalmology. It provides illumination and magnification
More informationULTRA-THIN CUSTOM CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS
ULTRA-THIN CUSTOM CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS FITTING SET PARAMETERS The Standard Fitting Set is available with 8 x 14.50mm diameter lenses comprising: 6 x STD periphery Base Curve
More informationThe angle of the anterior chamber needs to be assessed
Thomas George MS Common Tests Simplified Gonioscopy The angle of the anterior chamber needs to be assessed in all glaucomas. It usually holds the secrets to pathogenesis in that particular case. It may
More informationULTRA-THIN SPECIALIST CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS
ULTRA-THIN SPECIALIST CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS DIAMETER & PERIPHERY GUIDE KeraSoft Thin s increased flexibility improves drapage over the peripheral cornea. This reduces the need
More informationThe TRC-NW8F Plus: As a multi-function retinal camera, the TRC- NW8F Plus captures color, red free, fluorescein
The TRC-NW8F Plus: By Dr. Beth Carlock, OD Medical Writer Color Retinal Imaging, Fundus Auto-Fluorescence with exclusive Spaide* Filters and Optional Fluorescein Angiography in One Single Instrument W
More informationFREE DELIVERY. Exclusive & unbeatable prices for optometry students & pre reg optometrists worldwide. OCULUS TRIAL FRAMES See pages 3-7
OCULUS TRIAL FRAMES See pages 3-7 Exclusive & unbeatable prices for optometry students & pre reg optometrists worldwide VOLKS See pages 8-13 QUALITY MUG & PEN 2017-2018 With all orders over 75 DELIVERY
More information12.1. Human Perception of Light. Perceiving Light
12.1 Human Perception of Light Here is a summary of what you will learn in this section: Focussing of light in your eye is accomplished by the cornea, the lens, and the fluids contained in your eye. Light
More informationGreen Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500 US EDITION
Green Scan Laser PhotocoagulatorGYC-500 Vixi Green Laser PhotocoagulatorGYC-500 US EDITION The Small, Incredibly Versatile Green Laser Photocoagulator The GYC-500 Vixi / GYC-500 is a solid state green
More informationBiology 70 Slides for Lecture 1 Fall 2007
Biology 70 Part II Sensory Systems www.biology.ucsc.edu 1 2 intensity vs spatial position (image formation) color 3 4 motion depth (monocular) 5 6 1 depth (binocular) 1. In the lectures on perception we
More informationThe pattern scanning multi-color photocoagulator that puts you in control
The pattern scanning multi-color photocoagulator that puts you in control RETINAL PHOTOCOAGULATION LASER TRABECULOPLASTY LASER IRIDOTOMY Helping the world see clearly 2 INTEGRE PRO SCAN FROM ELLEX Transforming
More informationNOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.
NOW Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers Accommodating. Aberration Free. Aspheric. Accommodation Meets Asphericity in AO Merging Innovation & Proven Design The
More informationRefractive Surgery: Vance Thompson, MD, FACS Refractive Surgeon. Oculeve Wavetec Zeiss Mynosys LRG Equinox Precision Lens ORA Amaken EXCELLens
Refractive Surgery: My Way Vance Thompson, MD, FACS Refractive Surgeon Vance Thompson Vision Sioux Falls, SD Disclosures Abbott Medical Optics Alcon Avedro Calhoun Euclid Systems EyeBrain Medical Forsight
More informationROTATIONAL STABILITY MAKES THE DIFFERENCE
The Bi-Flex platform the proven platform of Excellence 01 Proven Stability less than 02 Optimal biomaterials 2 degrees long term rotation 03 Posterior Toric Lens surface with marks indicating the flat
More informationRediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information
Rediscover quality of life thanks to vision correction with technology from Carl Zeiss Patient Information 5 2 It was really w Vision defects: Light that goes astray For clear vision the eyes, cornea and
More information11/23/11. A few words about light nm The electromagnetic spectrum. BÓDIS Emőke 22 November Schematic structure of the eye
11/23/11 A few words about light 300-850nm 400-800 nm BÓDIS Emőke 22 November 2011 The electromagnetic spectrum see only 1/70 of the electromagnetic spectrum The External Structure: The Immediate Structure:
More informationOPHTHALMIC SURGICAL MODELS
OPHTHALMIC SURGICAL MODELS BIONIKO designs innovative surgical models, task trainers and teaching tools for the ophthalmic industry. Our surgical models present the user with dexterity and coordination
More informationCR-2 AF DIGITAL NON-MYDRIATIC RETINAL CAMERA. Superior Image Resolution and Auto Functionality
DIGITAL NON-MYDRIATIC RETINAL CAMERA Superior Image Resolution and Auto Functionality 1 superior RESOLUTION for earlier, more accurate detection GOOD ENOUGH IS NOT GOOD ENOUGH If you were having your vision
More informationChapter 6 Human Vision
Chapter 6 Notes: Human Vision Name: Block: Human Vision The Humane Eye: 8) 1) 2) 9) 10) 4) 5) 11) 12) 3) 13) 6) 7) Functions of the Eye: 1) Cornea a transparent tissue the iris and pupil; provides most
More informationOptical Coherence Tomography. RS-3000 Advance / Lite
Optical Coherence Tomography RS-3000 Advance / Lite See it in Advance See it in high resolution with the AngioScan* image. OCT-Angiography of choroidal neovascularization * AngioScan (OCT-Angiography)
More informationBETA Otoscopes & Ophthalmoscopes DIAGNOSTIC INSTRUMENTS
BETA Otoscopes & Ophthalmoscopes DIAGNOSTIC INSTRUMENTS Working toward better care. As healthcare continues to shift, providers are rethinking the importance of using the latest diagnostic instrument technologies
More informationChoosing the Proper Power for the IOL. Brannon Aden, MD Miles H. Friedlander, MD, FACS
Choosing the Proper Power for the IOL Brannon Aden, MD Miles H. Friedlander, MD, FACS Goal s of Surgery Have Changed. In past the goal was good visual outcome Now an equal goal is a good refractive outcome
More informationAdaptive Optics Phoropters
Adaptive Optics Phoropters Scot S. Olivier Adaptive Optics Group Leader Physics and Advanced Technologies Lawrence Livermore National Laboratory Associate Director NSF Center for Adaptive Optics Adaptive
More informationImage Modeling of the Human Eye
Image Modeling of the Human Eye Rajendra Acharya U Eddie Y. K. Ng Jasjit S. Suri Editors ARTECH H O U S E BOSTON LONDON artechhouse.com Contents Preface xiiii CHAPTER1 The Human Eye 1.1 1.2 1. 1.4 1.5
More informationAdvanced Technology IOLs
Introduction Advanced Technology IOLs Stephen V. Scoper, MD Virginia Eye Consultants 2013 Cataract surgery has a refractive element Patient expectations are increased Close is no longer good enough The
More informationOptical Coherence Tomography. RS-3000 Advance / Lite
Optical Coherence Tomography RS-3000 Advance / Lite 12 mm wide horizontal scan available with the RS-3000 Advance allows detailed observation of the vitreous body, retina, and choroid from the macula to
More information11/10/2015. Haag Streit Topcon Zeiss Kowa Add On Systems- OIS/Escalon and Others. The Original Design. Photo Slit lamp Systems. Who Makes Them?
The Original Design Photo Slit lamp Systems Who Makes Them? 1862-1930 Alvar Gullstrand Inventor of the Slit lamp illuminator - 1911 Swedish ophthalmologist, recipient of the 1911 Nobel Prize for Physiology
More informationOptical Coherence Tomography. RS-3000 Advance
Optical Coherence Tomography RS-3000 Advance See it in Advance See it in high resolution with the AngioScan* image. SLO Superficial capillary OCT-Angiography (3 x 3 mm) Deep capillary OCT-Angiography (3
More informationMEDICARE GB LTD LIGHTING CATALOGUE. Approved Luxo Dealer
2009-2010 MEDICARE GB LTD LIGHTING CATALOGUE Approved Luxo Dealer 1 Contents Page 1 Page 2 Page 3 Page 4 Page 5 Contents Carelite Carelite table and trolley Circus Medical LMF Medical Page 6 AIM 50 Page
More informationfamily of lens designs fitting guide ICD is Exclusively Manufactured In
TM family of lens designs fitting guide ICD is Exclusively Manufactured In paragon 1 Select Initial Diagnostic Lens: Identify the Corneal Condition Normal Depth Eyes Normal Shapes Median Flat KReading
More informationTHE EYE. People of Asian descent have an EPICANTHIC FOLD in the upper eyelid; no functional difference.
THE EYE The eye is in the orbit of the skull for protection. Within the orbit are 6 extrinsic eye muscles, which move the eye. There are 4 cranial nerves: Optic (II), Occulomotor (III), Trochlear (IV),
More informationCorporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome
Corporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome Ronald Krueger, MD Refractive Industry Challenges Diagnostic Improvement Optimal Laser Performance Corneal Factors
More informationSutureless Trocar-Cannula Based Transconjunctival Flanged Intrascleral Intraocular Lens Fixation
1:35 PM Sutureless Trocar-Cannula Based Transconjunctival Flanged Intrascleral Intraocular Lens Fixation Mark K. Walsh, MD, PhD OBJECTIVE To teach attendees a novel sutureless scleral intraocular lens
More informationAHEAD Superior technology, thoughtfully designed with you in mind for an intelligent approach to cataract surgery.
ALWAYS THINKING AHEAD Superior technology, thoughtfully designed with you in mind for an intelligent approach to cataract surgery. The LENSAR Laser System was designed with your efficiency in mind, so
More informationOptics of the Human Eye
Optics of the Human Eye References: Equipment: Ford, Kenneth W., Classical and Modern Physics Vol2 Xerox College Publishing 1972 pp. 900-922. Pasco Human Eye Model Instruction Manual (OS-8477) pp. 1-34.
More informationPhysics Chapter Review Chapter 25- The Eye and Optical Instruments Ethan Blitstein
Physics Chapter Review Chapter 25- The Eye and Optical Instruments Ethan Blitstein The Human Eye As light enters through the human eye it first passes through the cornea (a thin transparent membrane of
More informationEyeball Model Lab Date Block
Science 8 Name Eyeball Model Lab Date Block Problem: Identify the twelve key parts of the eye and describe their function. Materials: dissecting scissors ping pong ball transparent plastic ordinary scissors
More informationFEA of Prosthetic Lens Insertion During Cataract Surgery
Visit the SIMULIA Resource Center for more customer examples. FEA of Prosthetic Lens Insertion During Cataract Surgery R. Stupplebeen, C. Liu, X. Qin Bausch + Lomb, SIMULIA, SIMULIA Abstract: Cataract
More informationNEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL
NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL ALL TRIFOCAL IOLS ARE NOT THE SAME! Seamless Vision Near Intermediate Far Light Figure 1: Comparison of MTF Values 1,2 THE WORLD S FIRST AND ONLY
More informationSutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique
Published online: July 21, 2015 1663 2699/15/0062 0239$39.50/0 This is an Open Access article licensed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported license (CC BY-NC)
More informationFitting Manual Use with kerasofttraining.com
Fitting Manual Use with Fitting Manual: Contents This fitting manual is best used in conjunction with KeraSoft IC online training. To register, please visit www. 01 Kerasoft IC Design - Outlines the KeraSoft
More information