Product Tripix 300 Catalog number Lens Option Standard. Tripix300_ ies
|
|
- Cornelia Dean
- 6 years ago
- Views:
Transcription
1 Tripix 300 and 1200, Tripix 300 Standard (Without diffuser) (20 ) Photometric Report Martin R&D Optics Laboratory, 28-Jun-2010 Data sheet conforms to American National Standard E Product Tripix 300 Catalog number Lens Option Standard Spread N/A IES file Tripix300_ ies Procedure Test lamp Model Rated life The goniometer consists of a computerized robot IRB 6000 and a LMT Digital Illuminance Meter B 520 that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type C photometry in 15 increments in the horizontal plane (rotational) and 3 increments in the vertical plane (radial). 3-1 LED hours Test conditions Ambient temperature 25 ± 5 ºC Consumed power 40 W AC supply 230 V/50Hz Lamp age 65 hours Ballast Type Electronic Ballast factor Output Total One-tenth peak Half-peak Efficacy 360 lumens 280 lumens 130 lumens 9.1 lumens per watt Illuminance Cutoff angle 78 One-tenth-peak angle 47 Half-peak angle 20 Cutoff diameter x distance One-tenth-peak diam x distance Half-peak diam x distance Intended throw Luminous intensity Luminaire type meters 1800 candela Far field
2 100%=18 lux at 10m (distance from origin)=(throw distance) X (throw distance multiplier)
3
4 Tripix 300 and 1200, Tripix 300 Standard (Narrow diffuser) (24 ) Photometric Report Martin R&D Optics Laboratory, 03-Aug-2010 Data sheet conforms to American National Standard E Product Tripix 300 Catalog number Lens Option Standard Spread - IES file Tripix300_Standard_ ies Procedure Test lamp Model Rated life The goniometer consists of a computerized robot IRB 6000 and a LMT Digital Illuminance Meter B 520 that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type C photometry in 15 increments in the horizontal plane (rotational) and 3 increments in the vertical plane (radial). 3-1 LED hours Test conditions Ambient temperature 25 ± 5 ºC Consumed power 40 W AC supply 230 V/50Hz Lamp age 65 hours Ballast Type Electronic Ballast factor Output Total One-tenth peak Half-peak Efficacy 360 lumens 280 lumens 120 lumens 8.9 lumens per watt Illuminance Cutoff angle 95 One-tenth-peak angle 55 Half-peak angle 24 Cutoff diameter x distance One-tenth-peak diam x distance Half-peak diam x distance Intended throw Luminous intensity Luminaire type meters 1200 candela Far field
5 100%=12 lux at 10m (distance from origin)=(throw distance) X (throw distance multiplier)
6
7 Tripix 300 and 1200, Tripix 300 Standard (Medium diffuser) (49 ) Photometric Report Martin R&D Optics Laboratory, 12-Aug-2010 Data sheet conforms to American National Standard E Product Tripix 300 Catalog number Lens Option Medium Spread N/A IES file Tripix300_Medium_ ies Procedure Test lamp Model Rated life The goniometer consists of a computerized robot IRB 6000 and a LMT Digital Illuminance Meter B 520 that provides luminous intensity measurements for computerized data collection. The computerized robot IRB 6000 is initialized so that the center of the luminaire's front lens is positioned 7 m from the luxmeter. The luminaire is rotated around both the horizontal and vertical axis per IESNA's type C photometry in 15 increments in the horizontal plane (rotational) and 3 increments in the vertical plane (radial). 3-1 LED hours Test conditions Ambient temperature 25 ± 5 ºC Consumed power 40 W AC supply 230 V/50Hz Lamp age 66 hours Ballast Type Electronic Ballast factor Output Total One-tenth peak Half-peak Efficacy 210 lumens 210 lumens 170 lumens 5.3 lumens per watt Illuminance Cutoff angle 60 One-tenth-peak angle 59 Half-peak angle 49 Cutoff diameter x distance One-tenth-peak diam x distance Half-peak diam x distance Intended throw Luminous intensity Luminaire type meters 430 candela Far field
8 100%=4 lux at 10m (distance from origin)=(throw distance) X (throw distance multiplier)
9
Exterior 400. Balanced white 6500Kelvin. Catalog number Lens Option Standard. Exterior400_Standard_ ies
Exterior 400, Balanced White 6500K Standard (Without diffuser) (7.5 ) Photometric Report Martin R&D Optics Laboratory, 19-Jan-2011 Data sheet conforms to American National Standard E1.9-2001 Product Exterior
More informationMAC Quantum Profile Catalog number Lens Option Standard. MAC Quantum Profile_Standard_Minimum.ies
macquantumprofile, Standard Lens, Zoom at Minimum (12 ) Photometric Report Martin R&D Optics Laboratory, 15-Oct-2014 Data sheet conforms to American National Standard E1.9-2001 Product MAC Quantum Profile
More informationCatalog number Lens Option Very Narrow without diffuser Exterior200LED_VeryNarrow_withoutdiffuser_5600Kelvin.ies
Exterior 200 LED, Very Narrow (Balanced white 5600 Kelvin. Without diffuser) (13 ) Photometric Report Martin R&D Optics Laboratory, 31-Oct-2007 Data sheet conforms to American National Standard E1.9-2001
More informationMAC Viper Profile Catalog number Lens Option Standard. MACViperProfile_Standard_Minimum.ies
macviperprofile, Standard Lens, Zoom at Minimum (10 ) Photometric Report Martin R&D Optics Laboratory, 04-Jun-2012 Data sheet conforms to American National Standard E1.9-2001 Product MAC Viper Profile
More informationMAC Viper Performance Catalog number Lens Option Standard without beamsmoother. MACViperPerformance_Standard without beamsmoother_minimum.
macviperperformance, Standard (beamsmoother removed), Zoom at Minimum (10 ) Photometric Report Martin R&D Optics Laboratory, 04-Jun-2012 Data sheet conforms to American National Standard E1.9-2001 Product
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights Street Side House Side INDEPENDENT TESTING LABORATORIES, INC. 2 0 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 50 foot mounting height.
More informationElectrical Installation LectureNo.10 Dr.Mohammed Tawfeeq Al-Zuhairi. Luminous flux Luminous intensity Illuminance Luminance
Lighting Technology Basic parameters used in lighting Luminous flux Luminous intensity Illuminance Luminance Luminous flux Luminous flux (φ) is the light emitted by a source and is measured in lumens Symbol
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ.
Test #: L08124408 Date:08/31/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L08124408 RR61430W Report Prepared For: MAXLITE
More informationOPTIMAL PERFORMANCE REFLECTOR
OPTIMAL PERFORMANCE REFLECTOR ELECTRICAL DATA COMMON TO ALL GENERATORS Input Voltage 0V-77V EMI/RFI Compliance FCC Part 8-A Voltage Fluctuation Tolerance ±0% Sound Rating Class A Input Frequency 0/60 Hz
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L051411201 Date: 6/9/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L051411201 SPJ-720 Report Prepared For: SPJ LIGHTING
More informationLUXTRAN Luminaires for Tunnel Applications
PRODUCT FEATURES: Powered by distributed DC driver system; remotely-located for servicing convenience Suitable for supplemental lighting in transition zones with a ceiling or wall orientation Optical configurations
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L1212321 Date: 12/1/212 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: L1212321 Model Number: LT24-4L-35K Report Prepared For: Raffino Inc.
More informationNumber Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000
Report No: L121706545 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706545 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE Jersey Blvd. Rancho Cucamonga, CA 91730
Test #: L06122603 Date: 6/15/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L06122603 MLRT24D5535 Report Prepared For: MAXLITE
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights 2 1 0 1 2 3.05.1.2.5 1 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 15 foot mounting height..02.01.005.002.001 REPORT NUMBER: RAB00241
More informationTEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.
TEST REPORT Job No. 170400516SHA Date: Apr 12,2017 REPORT NO. 170400516SHA-006 TEST OF ONE LED Luminaire MODEL NO. RENDERED TO Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. TEST:
More informationLUXTRAN Luminaires for Tunnel Applications
PRODUCT FEATURES: Powered by distributed DC driver system; remotely-located for servicing convenience Suitable for supplemental lighting in transition zones with a ceiling or wall orientation Optical configurations
More informationCalibration Due Date Chroma Programmable AC Source 61604
Test #: L04130402 Date: 5/2/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L04130402 TVL4000 CW Report Prepared For: ELATION
More informationReport No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: KT-PLED50-24-850-VDIM /G2 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 117.9 6083.5 51.62 0.9926 CCT (K) CRI Stabilization Time (Light
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB01271 PAGE: 1 OF 5 LUMINAIRE: LUMINAIRE: FABRICATED WHITE PAINTED METAL HOUSING, 4 WHITE CIRCUIT BOARDS EACH WITH 120 LEDS, FROSTED HOLOGRAPHIC PLASTIC LENS. LENS FROSTED SIDE UP. LAMPS:
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L113411R1 Date: 1/28/213 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: Model Number: L113411R1 LR24-4L-5K-D-S Report Prepared For: Raffino
More informationEquipment Used Model No Stock No Calibration Due Date
Report No: L091401801 Date: 9/16/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L091401801 Report Prepared For: Olympia Lighting, inc. 50
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE SANDRA STREET, FRANKLIN PARK, IL 60131
Test #: L031611002 Date: 4/11/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L031611002 GARVIN INDUSTRIES
More informationdaylight Spring 2014 College of Architecture, Texas Tech University 1
daylight Spring 2014 College of Architecture, Texas Tech University 1 artificial light Spring 2014 College of Architecture, Texas Tech University 2 artificial light Spring 2014 College of Architecture,
More informationIES INDOOR REPORT PHOTOMETRIC FILENAME : FHBC48-LED114DMV35.IES. DESCRIPTION INFORMATION (From Photometric File)
DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] LLIA000738-001A [TESTLAB] LightLab International Allentown, LLC [MANUFAC] Mobern Lighting Co., 8200 Stayton Drive, Jessup, MD 20794,
More informationNo seasoning was performed in accordance with IESNA LM-79.
Test #: L01134102R01 Date: 1/28/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L01134102R01 LR24-5000L-50K-D-S Report Prepared
More informationIES INDOOR REPORT PHOTOMETRIC FILENAME : FHBC48-LED180DMV40.IES. DESCRIPTION INFORMATION (From Photometric File)
DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] LLIA000738-001A [TESTLAB] LightLab International Allentown, LLC [MANUFAC] Mobern Lighting Co., 8200 Stayton Drive, Jessup, MD 20794,
More informationClient submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary.
Report No: L031500702 Date: 3/13/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L031500702 Report Prepared For: EiKO Global, LLC 23220 W.
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22 UL1598-28 Prepared For Simkar Corporation Andre Duljas 7 Ramona Ave Philadelphia, PA 1912 United States Catalog Number RG2LEDWR1741U1
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L113141 Date: 1/8/213 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: L113141 Model Number: LR22-33L-35K Report Prepared For: Raffino Inc. Test:
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB01842 PAGE: 1 OF 6 CATALOG NUMBER: SWISH2X2-29YN/D10 LUMINAIRE: WHITE PAINTED SHEET METAL HOUSING, 2 WHITE CIRCUIT BOARDS EACH WITH 60 LEDS, FROSTED POLYCARBONATE LENS IN THE CENTER,
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008, ANSI C82.77-2002, CIE 13.3-1995 CIE 15-2004, ANSI C78.377-2015, IES TM-30-2015 Prepared For Smart Grow Technologies 69319 Panoramic Dr Sisters,
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.
Report No: L111503505 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111503505 Report Prepared For: Revolution Lighting Technologies
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.
Report No: L111503504 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111503504 Report Prepared For: Revolution Lighting Technologies
More informationElectrical Illumination and Design
EE512 Electrical Illumination and Design Prepared by: Engr. John Michael Abrera Table of Contents 1. Photometry 2. Laws of Illumination 3. Coefficient of Utilization 1 Photometry Photometry Photometry
More informationReport No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: LDP2450L35U1 2X4 3500K Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 102.3 5129.5 50.12 0.9883 CCT (K) CRI Stabilization Time (Light
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L071600301 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600301 Report Prepared For: Revolution Lighting Technologies
More informationLIGHT LABORATORY, INC E Kaiser Blvd. Anaheim, CA 92808
LIGHT LABORATORY, INC. 8165 E Kaiser Blvd. Anaheim, CA 92808 SHT 1 OF 5 Test #: L06110908 Date: 7/22/2011 Luminaire Photometric Performance LM-79-2008 Manufacturer: Model Number: ELATION LIGHTING TVL 2000
More informationModel No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02
Report No: L071600303 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600303 Report Prepared For: Revolution Lighting Technologies
More informationModel No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02
Report No: L041608503 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041608503 Report Prepared For: GM LIGHTING 9830 W 190th St,
More informationMANUFACTURE NAME 8165 E. KAISER BLVD, ANAHEIM, CA Electrical and Photometric tests as required by the IESNA test standards.
Test #: ROADWAY Date: S01130101 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: S01130101 LUMINAIRE CATALOG NUMBER Report Prepared
More informationFFW / LED Flood / Wall Pack Combo
The FFW LED/ Wall Pack Combo is an efficient, energy saving solution for replacing metal halide and high-pressure sodium fixtures. The combo design is an ideal lighting option for security, pathways, perimeters
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ., 07506
Report No: L111407206 Date: 12/11/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407206 Report Prepared For: Cast Lighting 1120-A Goffle
More informationSample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:
IES LM 79 08 Test Report Test results reported for: report: Original issue date: LED Lamp 001 LEDC001 010 WG 1 January 2012 Prepared for: Testing performed by: LED ABC, Inc. Memorial Highway 1003 7th Ave.
More informationMoon Visions Lighting 780 S. Floyd Rd., Suite 2B, Richardson, TX Electrical and Photometric tests as required by the IESNA test standards.
Test #: L061402510 Date: 6/16/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L061402510 LED MV120V R30 14W 5K FL Report Prepared
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008 Prepared For Lumificient Corp Deborah Jones 8752 Monticello Lane North Maple Grove, MN 55369-4549 Catalog Number EVG236-BB-AC-NW-UL1-XX
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L051603301 Date: 5/19/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051603301 Report Prepared For: Colt LED Model Number: D12X6-GEN3-55W
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ 07506
Report No: L071407704 Date: 8/6/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071407704 Report Prepared For: Cast Lighting 1120-A Goffle
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Kalanianaole Hwy # 29A Kailua, HI.
Report No: L061507817R01 Date: 8/10/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L061507817R01 Beachside
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L12125907R02 Date: 1/14/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L12125907R02 LR24-5000L-35K Report Prepared
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ., Fixture is tested with no special conditions.
Report No: L111407108 Date: 12/9/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407108 Report Prepared For: Cast Lighting 1120-A Goffle
More informationCompany synopsis. Regulations and Standards
Goniophotometer Company synopsis Pleiades Instruments is an optoelectronic system maker, designing and manufacturing for you specific systems such as photometric measurement and customized systems. Designing
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Myles Standish Blvd.
Report No: L051604201 Date: 6/1/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L051604201 Lexington Lighting
More informationLM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard
Lamp specifics: Luminaire Used: none none Rated Watts Voltage: 6.75 Watts Lamp Type: LPL-W18-120C-930 / 78875 / Rated Orientation CCT: VBD Test Requester E.Z. Cola Rated Voltage 12 V DC New Product: 1
More informationLM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22, UL 1598-28 UL1598-28 Prepared For AVID Labs Alexander Tollington 4121 Fourier Drive Fort Wayne, IN 46818 United States Product Name:
More informationNVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)
LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1 2 1.5.2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 25 foot mounting height. 11 1/2 17 7/8 11 0 11 REPORT
More informationEiKO Global, LLC W. 84th Street, Shawnee, KS 66227
Report No: L011508802 Date: 2/19/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L011508802 Report Prepared For: EiKO Global, LLC 23220 W.
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063
Report No: L121500506 Date: 12/9/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121500506 Report Prepared For: Revolution Lighting Technologies
More informationRecommendations for Testing and Evaluating Under-cabinet Luminaires
Recommendations for Testing and Evaluating Under-cabinet Luminaires Volume 2, Issue 3 2007 A publication of the Alliance for Solid-State Illumination Systems and Technologies Copyright 2007 by the Alliance
More informationRevolution Lighting 4139 Guardian St. Simi Valley CA 93063
Report No: L121605937R02 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121605937R02 Issue Date: 2/17/2017 Report Prepared For: Revolution Lighting 4139 Guardian St. Simi Valley
More information57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG
57-100W-XXK-WPH12-SG 57-100W-40K-WPH12-SG 57-100W-57K-WPH12-SG Eternal Shine Technology Co.,Ltd. EST 57-100W-XXK-WPH12-SG 1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard
More information(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary
Test Summary Sample Tested: LFC41327W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 45.3 544.6 12.02 0.9892 CCT Stabilization Time CRI (K) (Light & Power)
More informationPhotometric Indoor Test Report
Photometric Indoor Test Report Relevant Standards LM-79-28 Prepared For Sea Gull Lighting Andre Duljas 31 W. Washington Street Riverside, NJ 875 Catalog Number 96118S-32 LTL Test Number 2191 Test Date
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L10131601 Date: 10/10/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L10131601 ELED Strip TW BOTH A Report Prepared
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L041609601 Date: 5/5/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041609601 Report Prepared For: GM LIGHTING 9830 W 190th St,
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L061507801 Date: 7/20/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061507801 Report Prepared For: Beachside Lighting 905 Kalanianaole
More informationChecked X.CAO
REPORT NUMBER: RAB01900 PAGE: 1 OF 7 CATALOG NUMBER: BULLET12Y LUMINAIRE: CAST FINNED METAL HEAT SINK, MOLDED TEXTURED PLASTIC REFLECTOR WITH SEMI-DIFFUSE FINISH, 1 CIRCUIT BOARD WITH 24 LEDS, CLEAR MICRO-PRISMATIC
More informationBARTCO Lighting 5761 Research Drive, Huntington Beach, CA 92649
Report No: L101601204 Date: 10/18/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L101601204 Report Prepared For: BARTCO Lighting 5761 Research
More informationReport No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: L15T8SE450-G Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 125.1 1904.0 15.22 0.9679 CCT (K) CRI Stabilization Time (Light & Power)
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Kalanianaole Hwy # 29A Kailua, HI.
Report No: L061606303 Date: 8/1/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L061606303 Beachside Lighting
More informationBeachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI
Report No: L061606106 Date: 7/19/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061606106 Report Prepared For: Beachside Lighting 905 Kalanianaole
More informationMorris Products 53 Carey Road, Queensbury, NY 12804
Catalog Number 72662 UPC Number 60198672662 Description 8" Recessed Downlight 25 Watt Features Phillips LUMILED LUXEON 3030 LED's Can be installed in most 8" Downlights Aluminum Housing/Trim - paintable
More informationTechnical requirements. for solid-state lighting products (2010)
Technical requirements for solid-state lighting products (2010) I Contents 1. Definitions... 1 2. Scopes and requirements... 3 (1) Self-ballasted LED reflectors... 3 1 Scopes... 3 Technical requirements...
More informationTEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003
TEST REPORT Job No. 170101691SHA Date: February 19, 2017 REPORT NO. 170101691SHA-003 TEST OF Outdoor Full-Cutoff Wall-mounted Area Luminaires MODEL NO. WP-ADS30U-40B / WP-ADS30U-40B-PC RENDERED TO Maxlite,
More informationPhotometric Test Report
UL LLC 1075 W Lambert Rd Suite B Brea, CA 92821 Photometric Test Report Relevant Standards IES LM-79-2008, ANSI C82.77-2002, CIE 13.3-1995 CIE 15-2004, ANSI C78.377-2017, IES TM-30-2015 UL LLC 1075 W Lambert
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320
Report No: L061605301 Date: 6/16/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L061605301 HK Lighting Group
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ., Fixture is tested with no special conditions.
Report No: L111407109 Date: 12/9/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407109 Report Prepared For: Cast Lighting 1120-A Goffle
More informationNVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ
LM-79-08 Test Report For Maxlite Inc (Brand Name: ) 12 York Avenue, West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO84040W Test & Report By: Johnson Sun Engineer: Johnson Sun Date: Jun.10,2015
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB02177 PAGE: 1 OF 7 CATALOG NUMBER: SK21XL25RYY LUMINAIRE: STAMPED STEEL CEILING PAN WITH WHITE FINISH, 10 LED BOARDS EACH WITH 10 LEDS, ACRYLIC DROP LENS WITH SMOOTH FINISH. LAMPS: ONE-HUNDRED
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L121404501R02 Date: 12/22/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121404501R02 Report Prepared For: Texas Fluorescents
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ., 07506
Report No: L111407302 Date: 1/15/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407302 Report Prepared For: Cast Lighting 1120-A Goffle
More informationLighting Sciences
Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY ANGLE MEAN CP LUMENS
More informationLM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen
LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen High-bay Luminaires for Commercial and Industrial Buildings
More informationLighting Terminologies Introduction
Lighting Terminologies Introduction A basic understanding of lighting fundamentals is essential for specifiers and decision makers who make decisions about lighting design, installation and upgrades. Radiometry
More informationLED14.5WPAR30S/FL/827-DIM
LED14.5WPAR30S/FL/827-DIM TABLE OF CONTENTS 1 - GENERAL INFORMATION... 3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)... 3 1.2 OBJECTIVE... 3 1.3 TEST FACILITY DESCRIPTION... 4 1.4 TEST EQUIPMENT
More informationEternal Shine Technology Co.,Ltd. EST
Eternal Shine Technology Co.,Ltd. EST NO.7 Flood, Bldg A,Shenfubao Industry Park, Bonded area, Futian District,Shenzhen, China 57-40W-XXK-WPH06-SG 57-40W-40K-WPH06-SG 57-40W-57K-WPH06-SG Eternal Shine
More informationChecked X.CAO
REPORT NUMBER: RAB02068 PAGE: 1 OF 7 CATALOG NUMBER: FXLED78SF - FXLED78T (SF=SLIPFITTER MOUNT & T=TRUNNION MOUNT) LUMINAIRE: CAST FINNED METAL HOUSING, MOLDED PLASTIC REFLECTOR WITH SPECULAR FINISH AND
More informationLM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454
LM-79-08 Test Report For KEYSTONE TECHNOLOGIES LLC (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454 1x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): KT-PLED40-14-830-VDIM
More informationReport No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: FLS50U50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.1 5291.8 48.96 0.9859 CCT (K) CRI Stabilization Time (Light & Power) 5119
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB03145 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB03414 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT
More informationLM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923
LM-79-08 Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 Model(s): Spectrum Lighting SG12SQLED21W35KE1/12SQGW/3.5LA 8 May 2011 This test report presents the results of measurements
More informationCatalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White
Catalog Number 71694 UPC Number 60198671694 Description LED Spot Bullet Flood Light 42W 4204 Lumens White QPL ID # PWG6GTSQ Features Philips Lumiled LUXEON 3030 2D Voltage: 120-277VAC Isolated Driver Compartment
More informationLighting Sciences, Inc.
Lighting Sciences, Inc. Color and Photometric Testing, According to IESNA LM 79 Standards and Procedures, Test Report Files for: Par 30, 9W, DWF, Dimmable, 120V, Glass (SKU #180064) Seesmart 4139 Guardian
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L051503011 Date: 5/21/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051503011 Report Prepared For: USTE, dba Vista Professional
More informationNVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ
LM-79-08 Test Report For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO61840W Representative (Tested) Model: RRECO61840W Test & Report By: Johnson
More informationAddress: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K
Customer Company & Address: Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Contact Person: Mohit K Mittal Phone Number: +91 9811204494 Email Address: mohit@overdriveasia.com Relevant
More informationLM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model
More information