ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
|
|
- Ira Barton
- 6 years ago
- Views:
Transcription
1 Transverse Distance in Units of Mounting Heights Street Side House Side INDEPENDENT TESTING LABORATORIES, INC. 2 0 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 50 foot mounting height. 26 7/ /6 REPORT NUMBER: ITL7838 PAGE: OF 7 CATALOG NUMBER: CPSNM57A55X LUMINAIRE: CAST METAL BALLAST HOUSING, SPUN METAL REFLECTOR HOUSING, FABRICATED SEGMENTED MULTI-FACETED PREMIUM SPECULAR METAL REFLECTOR WITH PREMIUM SEMI-SPECULAR LOWER PERIMETER, FLAT DIFFUSE METAL REFLECTOR MOUNTING RING, CLEAR FLAT GLASS LENS IN FORMED SEMI-DIFFUSE METAL FRAME. LAMP: ONE 575-WATT CLEAR BT-37 PROTECTED PULSE START METAL HALIDE, VENTURE MP 575W/BU/BT-37/PS/740, VERTICAL BASE-UP POSITION. BALLAST: VENTURE V90Y550T, ACG 32 38uF CAPACITOR, VENTURE BVS-04 IGNITOR TOTAL INPUT WATTS = AT VOLTS NOTE: THIS RELATIVE PHOTOMETRIC TEST WAS PERFORMED AT RATED INPUT VOLTAGE (480VAC, 60Hz) TO THE BALLAST. REPORT BASED ON LUMENS PER LAMP. IES Cutoff Classification: Full Cutoff Checked Approved B HYRE R BEATTIE Lighting Engineer Longitudinal Distance in Units of Mounting Heights
2 REPORT NUMBER: ITL7838 PAGE: 2 OF 7 CATALOG NUMBER: CPSNM57A55X LUMINAIRE: CAST METAL BALLAST HOUSING, SPUN METAL REFLECTOR HOUSING, FABRICATED SEGMENTED MULTI-FACETED PREMIUM SPECULAR METAL REFLECTOR WITH PREMIUM SEMI-SPECULAR LOWER PERIMETER, FLAT DIFFUSE METAL REFLECTOR MOUNTING RING, CLEAR FLAT GLASS LENS IN FORMED SEMI-DIFFUSE METAL FRAME. LAMP: ONE 575-WATT CLEAR BT-37 PROTECTED PULSE START METAL HALIDE, VENTURE MP 575W/BU/BT-37/PS/740, VERTICAL BASE-UP POSITION. BALLAST: VENTURE V90Y550T, ACG 32 38uF CAPACITOR, VENTURE BVS-04 IGNITOR TOTAL INPUT WATTS = AT VOLTS NOTE: THIS RELATIVE PHOTOMETRIC TEST WAS PERFORMED AT RATED INPUT VOLTAGE (480VAC, 60Hz) TO THE BALLAST. REPORT BASED ON LUMENS PER LAMP. MAXIMUM PLANE AND MAXIMUM CONE PLOTS OF CANDELA CANDELA 90 HOUSE SIDE 90 STREET SIDE VERTICAL PLANE THROUGH MAXIMUM CANDELA CONE THROUGH MAXIMUM CANDELA 70.0 (Degrees Vertical) 20.0 (Degrees Horizontal) = 6255
3 REPORT NUMBER: ITL7838 PAGE: 3 OF 7 COEFFICIENTS OF UTILIZATION AND FLUX DISTRIBUTION Coefficients of Utilization STREET SIDE HOUSE SIDE Street Width / Mounting Height LUMENS PERCENT OF LAMP DOWNWARD STREET SIDE DOWNWARD HOUSE SIDE DOWNWARD TOTAL UPWARD STREET SIDE UPWARD HOUSE SIDE UPWARD TOTAL TOTAL FLUX ALL CANDELA, LUMENS AND COEFFICIENT OF UTILIZATION VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF.00. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR.
4 REPORT NUMBER: ITL7838 PAGE: 4 OF 7 FLUX DISTRIBUTION BY SOLID ANGLE (PER IESNA TM-5-, LUMINAIRE CLASSIFICATION SYSTEM FOR OUTDOOR LUMINAIRES) PERCENT BUG OF ZONE LUMENS LAMP RATINGS FORWARD LIGHT FL ( 0-30) FM ( 30-60) FH ( 60-80) G4 FVH( 80-90) G4 BACK LIGHT BL ( 0-30) B3 BM ( 30-60) B5 BH ( 60-80) B5 G4 BVH( 80-90) G4 UPLIGHT UL ( 90-00) U0 UH (00-80) U0 TRAPPED LIGHT TOTAL FLUX BACKLIGHT, UPLIGHT, AND GLARE (BUG) RATINGS (PER ADDENDUM A FOR IESNA TM-5-) BUG RATING: B5 U0 G4
5 REPORT NUMBER: ITL7838 PAGE: 5 OF 7 CANDELA TABULATION LATERAL ANGLE << V E R T I C A L A N G L E PLANE OF MAXIMUM CANDELA CONE OF MAXIMUM CANDELA
6 REPORT NUMBER: ITL7838 PAGE: 6 OF 7 CANDELA TABULATION LATERAL ANGLE << V E R T I C A L A N G L E CONE OF MAXIMUM CANDELA
7 REPORT NUMBER: ITL7838 PAGE: 7 OF 7 5-DEGREE 0-DEGREE ZONAL LUMEN SUMMARY ZONAL LUMEN SUMMARY
ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights 2 1 0 1 2 3.05.1.2.5 1 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 15 foot mounting height..02.01.005.002.001 REPORT NUMBER: RAB00241
More informationCONE THROUGH MAXIMUM CANDELA 57.5 (Degrees Vertical)
REPORT NUMBER: ITL72395 PAGE: 2 OF 7 PREPARED FOR: ECONOLIGHT, A DIVISION OF RUUD LIGHTING CATALOG NUMBER: E-WP4L06CZ LUMINAIRE: CAST BLACK PAINTED FINNED METAL HOUSING, 2 CIRCUIT BOARDS EACH WITH ONE
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1.2.5 1 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 25 foot mounting height. 11 1/2 17 7/8 11 0.1.05.02.01.005
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1 2 1.5.2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 25 foot mounting height. 11 1/2 17 7/8 11 0 11 REPORT
More informationCatalog Number UPC Number
Catalog Number 71304 UPC Number 60198671306 Description LED WallPack 10 LED 1019 Lumen Features Cree XPE LED s Voltage: 120-277Vac (120/208/240/277V) Dark Sky Type II Cutoff Light Pattern culus listed
More informationCatalog Number UPC Number
Catalog Number 71306 UPC Number 60198671306 Description LED WallPack 15 LED 1700 Lumen Features Cree XPE LED s Voltage: 120-277Vac (120/208/240/277V) Dark Sky Type II Cutoff Light Pattern culus listed
More informationCatalog Number UPC Number
Catalog Number 71302 UPC Number 60198671302 Description LED WallPack 5 LED 655 Lumen Features Cree XPE LED s Voltage: 120-277Vac (120/208/240/277V) Dark Sky Type II Cutoff Light Pattern culus listed for
More informationTest Sample Description Catalog Number: Description:
Project Number Date 17.02759 10/12/2017 Test Sample Description Catalog Number: Description: P5641-3130K 6" 29W LED Down-Light Cylinder LAB 1 Sphere Photometry Test Method: Preburn Time: Time To Stabilize:
More informationMANUFACTURE NAME 8165 E. KAISER BLVD, ANAHEIM, CA Electrical and Photometric tests as required by the IESNA test standards.
Test #: ROADWAY Date: S01130101 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: S01130101 LUMINAIRE CATALOG NUMBER Report Prepared
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L051411201 Date: 6/9/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L051411201 SPJ-720 Report Prepared For: SPJ LIGHTING
More informationPOST TOP FIXTURE C40T
PROJECT TYPE VOLTAGE POST TOP FIXTURE C4T Wave Lighting s commercial product line provides safety and security for all types of applications including parks, pedestrian walkways, and parking areas. Our
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Kalanianaole Hwy # 29A Kailua, HI.
Report No: L061507817R01 Date: 8/10/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L061507817R01 Beachside
More informationUSTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063
Report No: L091706906 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L091706906 Issue Date: 10/9/2017 Report Prepared For: USTE, dba Vista Professional Outdoor Lighting 1625 Surveyor
More informationUSTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063
Report No: L091706904 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L091706904 Issue Date: 10/9/2017 Report Prepared For: USTE, dba Vista Professional Outdoor Lighting 1625 Surveyor
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ., 07506
Report No: L111407206 Date: 12/11/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407206 Report Prepared For: Cast Lighting 1120-A Goffle
More informationBeachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI
Report No: L061606106 Date: 7/19/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061606106 Report Prepared For: Beachside Lighting 905 Kalanianaole
More informationReport No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample
Test Summary Sample Tested: AR-MAL100UT3-40X Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 131.6 12593.0 95.69 0.9967 CCT (K) CRI Stabilization Time (Light &
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008 Prepared For Lumificient Corp Deborah Jones 8752 Monticello Lane North Maple Grove, MN 55369-4549 Catalog Number EVG236-BB-AC-NW-UL1-XX
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ 07506
Report No: L071407704 Date: 8/6/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071407704 Report Prepared For: Cast Lighting 1120-A Goffle
More informationEiKO Global, LLC W. 84th Street, Shawnee, KS 66227
Report No: L011508802 Date: 2/19/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L011508802 Report Prepared For: EiKO Global, LLC 23220 W.
More informationsoft vue 15 Like Us On:
soft vue 15 www.sternberglighting.com Like Us On: 2 Visit www.sternberglighting.com for more product details and LED updates technology SURFACE BRIGHTNESS LUMINANCE PERFORMANCE Soft Vue lenses give a soft
More informationPhotometric Test Report
UL LLC 1075 W Lambert Rd Suite B Brea, CA 92821 Photometric Test Report Relevant Standards IES LM-79-2008, ANSI C82.77-2002, CIE 13.3-1995 CIE 15-2004, ANSI C78.377-2017, IES TM-30-2015 UL LLC 1075 W Lambert
More informationProduct Tripix 300 Catalog number Lens Option Standard. Tripix300_ ies
Tripix 300 and 1200, Tripix 300 Standard (Without diffuser) (20 ) Photometric Report Martin R&D Optics Laboratory, 28-Jun-2010 Data sheet conforms to American National Standard E1.9-2001 Product Tripix
More informationCatalog number Lens Option Very Narrow without diffuser Exterior200LED_VeryNarrow_withoutdiffuser_5600Kelvin.ies
Exterior 200 LED, Very Narrow (Balanced white 5600 Kelvin. Without diffuser) (13 ) Photometric Report Martin R&D Optics Laboratory, 31-Oct-2007 Data sheet conforms to American National Standard E1.9-2001
More informationFFW / LED Flood / Wall Pack Combo
The FFW LED/ Wall Pack Combo is an efficient, energy saving solution for replacing metal halide and high-pressure sodium fixtures. The combo design is an ideal lighting option for security, pathways, perimeters
More informationCOLLEGE EDITION. Spring City s Revolutionary LED. Technology
Spring City s Revolutionary LED Technology COLLEGE EDITION LED Luminaires Offer Better Light Dispersion Spring City s new LED light system is not only more cost-effective to operate and maintain than
More informationMAC Quantum Profile Catalog number Lens Option Standard. MAC Quantum Profile_Standard_Minimum.ies
macquantumprofile, Standard Lens, Zoom at Minimum (12 ) Photometric Report Martin R&D Optics Laboratory, 15-Oct-2014 Data sheet conforms to American National Standard E1.9-2001 Product MAC Quantum Profile
More informationExterior 400. Balanced white 6500Kelvin. Catalog number Lens Option Standard. Exterior400_Standard_ ies
Exterior 400, Balanced White 6500K Standard (Without diffuser) (7.5 ) Photometric Report Martin R&D Optics Laboratory, 19-Jan-2011 Data sheet conforms to American National Standard E1.9-2001 Product Exterior
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22, UL 1598-28 UL1598-28 Prepared For AVID Labs Alexander Tollington 4121 Fourier Drive Fort Wayne, IN 46818 United States Product Name:
More informationMAC Viper Profile Catalog number Lens Option Standard. MACViperProfile_Standard_Minimum.ies
macviperprofile, Standard Lens, Zoom at Minimum (10 ) Photometric Report Martin R&D Optics Laboratory, 04-Jun-2012 Data sheet conforms to American National Standard E1.9-2001 Product MAC Viper Profile
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22 UL1598-28 Prepared For Simkar Corporation Andre Duljas 7 Ramona Ave Philadelphia, PA 1912 United States Catalog Number RG2LEDWR1741U1
More informationMAC Viper Performance Catalog number Lens Option Standard without beamsmoother. MACViperPerformance_Standard without beamsmoother_minimum.
macviperperformance, Standard (beamsmoother removed), Zoom at Minimum (10 ) Photometric Report Martin R&D Optics Laboratory, 04-Jun-2012 Data sheet conforms to American National Standard E1.9-2001 Product
More informationIES INDOOR REPORT PHOTOMETRIC FILENAME : FHBC48-LED114DMV35.IES. DESCRIPTION INFORMATION (From Photometric File)
DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] LLIA000738-001A [TESTLAB] LightLab International Allentown, LLC [MANUFAC] Mobern Lighting Co., 8200 Stayton Drive, Jessup, MD 20794,
More informationIES INDOOR REPORT PHOTOMETRIC FILENAME : FHBC48-LED180DMV40.IES. DESCRIPTION INFORMATION (From Photometric File)
DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] LLIA000738-001A [TESTLAB] LightLab International Allentown, LLC [MANUFAC] Mobern Lighting Co., 8200 Stayton Drive, Jessup, MD 20794,
More informationWelcome, to Altech Academy!
Welcome, to Altech Academy! Lighting Revolution Lighting is a Science and an Art IESNA - The Illuminating Engineering Society of North America - www.ies.org AIA - The American Institute of Architects -
More informationAMLED Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent
Applications Features 2 Standard Materials Standard Finishes Floodlight High Bay Certifications and Compliances ATEX/IECEx Certification See Table on following page See Table on following page EURASEC
More informationIntroduction Shank Road Pearland, Texas Fax:
AE-DS1 Introduction Light pollution caused by some outdoor lighting, is a major concern for a growing number of cities, states, environmental organizations, and even the Federal Government. The primary
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ.
Test #: L08124408 Date:08/31/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L08124408 RR61430W Report Prepared For: MAXLITE
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE Jersey Blvd. Rancho Cucamonga, CA 91730
Test #: L06122603 Date: 6/15/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L06122603 MLRT24D5535 Report Prepared For: MAXLITE
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L1212321 Date: 12/1/212 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: L1212321 Model Number: LT24-4L-35K Report Prepared For: Raffino Inc.
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L113411R1 Date: 1/28/213 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: Model Number: L113411R1 LR24-4L-5K-D-S Report Prepared For: Raffino
More informationNo seasoning was performed in accordance with IESNA LM-79.
Test #: L01134102R01 Date: 1/28/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L01134102R01 LR24-5000L-50K-D-S Report Prepared
More informationDesigned for flexibility and performance, wherever people need durable outdoor luminaries. Paraflood Series
Designed for flexibility and performance, wherever people need durable outdoor luminaries Paraflood Series Keene MAKES LIGHT WORK Change The one constant of which we can all be sure. As buildings mature
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008, ANSI C82.77-2002, CIE 13.3-1995 CIE 15-2004, ANSI C78.377-2015, IES TM-30-2015 Prepared For Smart Grow Technologies 69319 Panoramic Dr Sisters,
More informationDark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:
Catalog Number UPC Number Description 71452 60198671452 Dark Sky Wallpack 50W Features Full Cutoff Design to Prevent Up Light Integral Cooling Fins Release Heat Efficiently Corrosion Resistant Die Cast
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L12125907R02 Date: 1/14/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L12125907R02 LR24-5000L-35K Report Prepared
More informationHarnessing, Amplifying, and Vectoring the LED for Area Illumination
Harnessing, Amplifying, and Vectoring the LED for Area Illumination Closure Plate or Door Frame Module Air Flow Perimeter Vents Provide convective cooling with any air flow. Typical Luminaire Housin Protects
More informationNVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W
LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-50W Representative (Tested) Model: WML-50NW WML-50CW Model Different: All construction and rating
More informationNVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires
LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-30W Remark: X=CCT(4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB03414 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB03145 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT
More information57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG
57-100W-XXK-WPH12-SG 57-100W-40K-WPH12-SG 57-100W-57K-WPH12-SG Eternal Shine Technology Co.,Ltd. EST 57-100W-XXK-WPH12-SG 1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.
Report No: L111503505 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111503505 Report Prepared For: Revolution Lighting Technologies
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.
Report No: L111503504 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111503504 Report Prepared For: Revolution Lighting Technologies
More informationCatalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White
Catalog Number 71694 UPC Number 60198671694 Description LED Spot Bullet Flood Light 42W 4204 Lumens White QPL ID # PWG6GTSQ Features Philips Lumiled LUXEON 3030 2D Voltage: 120-277VAC Isolated Driver Compartment
More informationCalibration Due Date Chroma Programmable AC Source 61604
Test #: L04130402 Date: 5/2/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L04130402 TVL4000 CW Report Prepared For: ELATION
More informationMorris Products 53 Carey Road, Queensbury, NY 12804
Catalog Number UPC Number Description 71466A 60198671466 LED Vandal Resistant Canopy Light 80W Voltage: 120/277 Features Corrosion Die Cast Aluminum Housing Prismatic Polycarbonate Lens Superior Architectural
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L061507801 Date: 7/20/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061507801 Report Prepared For: Beachside Lighting 905 Kalanianaole
More informationMorris Products 53 Carey Road, Queensbury, NY 12804
Catalog Number 71462 UPC Number 60198671462 Description LED Vandal Resistant Canopy Light 40W Voltage: 120/277 Features Corrosion Die Cast Aluminum Housing Prismatic Polycarbonate Lens Superior Architectural
More informationLM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model
More informationReport No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: LDP2450L35U1 2X4 3500K Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 102.3 5129.5 50.12 0.9883 CCT (K) CRI Stabilization Time (Light
More informationNVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W
LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWA-50W Remark: X=CCT(3=3000K,4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits to indicate
More informationClient submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary.
Report No: L031500702 Date: 3/13/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L031500702 Report Prepared For: EiKO Global, LLC 23220 W.
More informationLM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model
More informationNVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)
LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L121404501R02 Date: 12/22/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121404501R02 Report Prepared For: Texas Fluorescents
More informationDOUGLAS COUNTY ZONING RESOLUTION Section 30 Lighting Standards 3/10/99. -Section Contents-
SECTION 30 LIGHTING STANDARDS -Section Contents- 3001 Intent... 30-2 3002 Applicability... 30-2 3003 Exceptions... 30-2 3004 Prohibited Lighting... 30-2 3005 General Requirements... 30-3 3006 Sign Lighting...
More informationEternal Shine Technology Co.,Ltd. EST
Eternal Shine Technology Co.,Ltd. EST NO.7 Flood, Bldg A,Shenfubao Industry Park, Bonded area, Futian District,Shenzhen, China 57-40W-XXK-WPH06-SG 57-40W-40K-WPH06-SG 57-40W-57K-WPH06-SG Eternal Shine
More informationLED Fundamentals and Roadway Lighting. Javier Urrea / Steve Ekblad
LED Fundamentals and Roadway Lighting Javier Urrea / Steve Ekblad March 28 th, 2013 1 Learning Objectives Basic lighting metrics important in the outdoor space. LCS, Photometric Report, Roadway classifications
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires
More informationAPPENDIX H. Town of Oakville. Street Lighting Standard. Ora t 1.0 (]) OAKY I LLE
Town of Oakville Street Lighting Standard Ora t 1.0 1 (]) OAKY I LLE Table of Contents A. Preamble... 3 B. Street Lighting Definitions... 3 C. Scope... 3 D. Master Street Lighting Plan... 3 I. Lighting
More informationBasic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined)
Basic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined) Accent Lighting Directional lighting to emphasize a particular object or draw attention to a display
More informationQPL ID # PLG2YNJ831VZ
Catalog Number 71732 UPC Number 60198671732 Description UFO High Bay 100W Features Integral Cooling Fins Release Heat Efficiently Corrosion Resistant Die Cast Aluminum Housing Polycarbonate Lens Superior
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE SANDRA STREET, FRANKLIN PARK, IL 60131
Test #: L031611002 Date: 4/11/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L031611002 GARVIN INDUSTRIES
More informationModel No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02
Report No: L071600303 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600303 Report Prepared For: Revolution Lighting Technologies
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L071600301 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600301 Report Prepared For: Revolution Lighting Technologies
More informationNVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006
LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)
More informationEquipment Used Model No Stock No Calibration Due Date
Report No: L091401801 Date: 9/16/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L091401801 Report Prepared For: Olympia Lighting, inc. 50
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):
More informationPhotometric Indoor Test Report
Photometric Indoor Test Report Relevant Standards LM-79-28 Prepared For Sea Gull Lighting Andre Duljas 31 W. Washington Street Riverside, NJ 875 Catalog Number 96118S-32 LTL Test Number 2191 Test Date
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L051603301 Date: 5/19/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051603301 Report Prepared For: Colt LED Model Number: D12X6-GEN3-55W
More informationCat# LED Wall-PACK
Cat# 71426 LED Wall-PACK OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle
More informationVG Series LED Parking Structure Luminaire
VG Series LED Parking Structure Luminaire Used for Pendant, Hook & Cord, Junction Box, Direct and Trunnion Mounts Reinventing LED Parking Structure Lighting ENHANCED DRAMATIC PLEASING QUICK AND RELIABLE
More informationReport No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: WPL40AU50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 91.6 3480.4 37.99 0.9907 CCT (K) CRI Stabilization Time (Light & Power) 5257
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L113141 Date: 1/8/213 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: L113141 Model Number: LR22-33L-35K Report Prepared For: Raffino Inc. Test:
More informationRTR / LED Troffer Conversion Kit
The LED troffer kits are designed by our expert in house lighting engineers and fabricated with custom made multi-stage roll forming machinery. This retrofit kit is an excellent alternative to standard
More informationChecked X.CAO
REPORT NUMBER: RAB01900 PAGE: 1 OF 7 CATALOG NUMBER: BULLET12Y LUMINAIRE: CAST FINNED METAL HEAT SINK, MOLDED TEXTURED PLASTIC REFLECTOR WITH SEMI-DIFFUSE FINISH, 1 CIRCUIT BOARD WITH 24 LEDS, CLEAR MICRO-PRISMATIC
More informationCat# LED Classic Large Wall-Pack
Cat# 71440 LED Classic Large Wall-Pack OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC OTHERS Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency
More informationNumber Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000
Report No: L121706545 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706545 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB01271 PAGE: 1 OF 5 LUMINAIRE: LUMINAIRE: FABRICATED WHITE PAINTED METAL HOUSING, 4 WHITE CIRCUIT BOARDS EACH WITH 120 LEDS, FROSTED HOLOGRAPHIC PLASTIC LENS. LENS FROSTED SIDE UP. LAMPS:
More information(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary
Test Summary Sample Tested: LFC41327W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 45.3 544.6 12.02 0.9892 CCT Stabilization Time CRI (K) (Light & Power)
More informationLM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA
LM-79-08 Test Report For Revolution Lighting Technologies, Inc (Brand Name: ) 2280 Ward Ave. Simi Valley, CA. 93065 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): 113XS8-3LT Remark:
More informationChecked X.CAO
REPORT NUMBER: RAB02068 PAGE: 1 OF 7 CATALOG NUMBER: FXLED78SF - FXLED78T (SF=SLIPFITTER MOUNT & T=TRUNNION MOUNT) LUMINAIRE: CAST FINNED METAL HOUSING, MOLDED PLASTIC REFLECTOR WITH SPECULAR FINISH AND
More informationNVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ
LM-79-08 Test Report For Maxlite Inc (Brand Name: ) 12 York Avenue, West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO84040W Test & Report By: Johnson Sun Engineer: Johnson Sun Date: Jun.10,2015
More informationNVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire
LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA ) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Full-Cutoff Wall-mounted Area Luminaire Model
More informationFinia LED Outdoor Lighting, Generation 2. A complete family of fixtures covering the parking lot to the building entrance
Finia LED Outdoor Lighting, Generation A complete family of fixtures covering the parking lot to the building entrance Finia LED Generation Luminaires Wall Mounted p. -... Area Light p. 4-... Flood Light
More informationTHE CITY OF TROY S CODE OF ORDINANCES CHAPTER 3 BUILDING REGULATIONS ARTICLE 3.13 OUTDOOR LIGHTING
Sec. 3.13.001 Popular Name THE CITY OF TROY S CODE OF ORDINANCES CHAPTER 3 BUILDING REGULATIONS ARTICLE 3.13 OUTDOOR LIGHTING This Article shall be known as the Lighting Ordinance. Sec. 3.13.002 Purpose
More informationNVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS
LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th St., Shawnee, KS 66227. Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): WPT1-55/8XX-BZ-U Remark:The letter X in the model name stands
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063
Report No: L121500506 Date: 12/9/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121500506 Report Prepared For: Revolution Lighting Technologies
More information