SECTION VI SCOPE OF WORK

Similar documents
SECTION VI SCOPE OF WORK

SPECIFICATION FOR SAFETY POLE SIGNS & ACCESSORIES

SECTION - II BID DATA SHEET

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

DESIGN PRACTICE NOTE DESIGN/REVIEW REQUIREMENTS FOR TRACTION BONDING PLAN

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

James W. Moore, PE / Brandon D. Enevold, PE / Kjersten E. Kuhta, PE Dylan J. Cunningham, PE / Jacob L. Deering, PE / Joel R.

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE. Contents

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

VI 3 - i TABLE OF CONTENTS

Click to edit Master title style. Click to edit Master title style. Northern Powergrid Asset Recording Guidance

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

ECP HV INSULATION TESTING

Guideline for Creating Disconnection Points and Establishing a Not Electrically Connected Area

PROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA

Transmission of Electrical Energy

Chapter 25. Lighting Plans

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

GENERAL TECHNICAL SPECIFICATION (Turnkey Work)

EI HIGH VOLTAGE INSULATION TESTING POLICY

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

Standard Prices for Generators 2010

Busbar and Modular Wiring Systems

Reference Number PCP 02 (RIC Standard: EP SP)

MESP TECHNICAL SPECIFICATION FOR FLEXIBLE DROPPER WIRE TIN-BEARING COPPER 7/7/ mm 2

50-SDMS-01 SPECIFICATIONS FOR

TECHNICAL SPECIFICATION FOR. CONTACT WIRE HARD-DRAWN COPPER 161mm2

TABLE OF CONTENTS. 1.0 Scope. 2.0 References. 3.0 Definitions. 4.0 Submission and Design Requirements. 5.0 Materials 5.1 General 5.

MPA Project No. M495-C1 Refrigerated Container Storage Improvements Project Location: Conley Terminal, Boston, MA

Software Services, Section 16748, Add as an attachment to this section Attachment A enclosed with this addendum.

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

TECHNICAL SPECIFICATION FOR ANNUBAR (DELTA TUBE)

Fatima Michael college of Engineering and Technology

ECP HV INSULATION TESTING

GENERAL TECHNICAL SPECIFICATION

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

EE 340 Transmission Lines. Spring 2012

ATTACHMENT - AESO FUNCTIONAL SPECIFICATION

Functional Specification Revision History

SINGLE-PHASE VSV SWITCH

ULC STANDARDS TECHNICAL WORK PROGRAM (WTO) Last modified on:

Overvoltage Protection

Customer Requirements RF Antenna Installations

015 : 1993 CEB STANDARD

Testing Manual for Electrical Equipment

SINGLE-PHASE VSV SWITCH

FTMG kV Transmission Line Steel Pole Bid June 1, 2017 Response to Bidders Questions

NSP/007/019 - Guidance on Substation Design: EHV Substation Drawing Policy

Construction Technology for Use in Repeatered Transoceanic Optical Submarine Cable Systems

Electrical IP Red Seal Practice Exam

MESP TECHNICAL SPECIFICATION FOR BARE FLEXIBLE ANNEALED COPPER JUMPER WIRE 37/7/ mm 2

FAQ ON EARTHING STANDARDS 16/08/2018

conductor Extruded Cross - Linked Polyethylene Insulated (XLPE) Power Cable Rated Voltage U 0 /U = 12/20 kv U 0 /U = 18/30 kv

FXL-168 FIXED RACK ASSEMBLY INSTRUCTIONS SALES ORDER #

CONTINUING EDUC ATION

ANNEXURE-I. Documents to be uploaded 1 Certificate of Registration with Industries 2 VAT Certificate 3 Service Tax Certificate

LOCOMOTIVE ENGINEERING DEPTT.

T E C H N I C A L M E M O R A N D U M. ON PARTICULAR ASPECTS RELATED 400 kv TRANSMISSION

Optical Ground Wires (OPGW)

Attached is Addendum No. 2 to SEPTA Sealed Bid APES, Install DC Stinger Distribution System - SEPTA Fern Rock Car House.

SPECIAL SPECIFICATION LIGHTNING PROTECTION SYSTEM

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

SECTION 2 GENERAL REQUIREMENTS

Premoulded cable joint SMPGB

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

ECP DISTRIBUTION TRANSFORMER COMMISSIONING PROCEDURE

DESIGN OF A 45 CIRCUIT DUCT BANK

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

THE KENYA POWER AND LIGHTING CO. LTD. SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT

PRACTICE NOTE NO: 13 Version 1 Amended March 2001 Page 1 of 6 PRECAST CONCRETE ELEMENT DESIGN RESPONSIBILITIES AND CONTRACTUAL ARRANGEMENTS

ELECTRICAL WORKS PART 1 - GENERAL 1.01 SCOPE OF WORK

Answer: Only to ChurchWoods, LLC.

Technical Specification. for 1.1 KV Copper Control Cable

SPECIAL PROVISION Description of Project, Scope of Contract and Sequence of Work

Cutters. Section. HUBBELL / CHANCE CENTRALIA, MISSOURI Printed in USA FEBRUARY 2009

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

Suggested Traffic Signal Design Procedures Indefinite Delivery (ID) Contract Locations and Conventional Signal Contract Locations

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS. Notification of Completed Conduit Sections

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

Page Electric Utility Service Specifications

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS

Request for Quotation (RFQ)

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

Form-IV. Form of Inspection/Test Report. (Under Regulation 43)

BVM Systems Limited. PQSensor MkIII Installation & Commissioning Manual - 1 -

Construction Phase Project Management and Documentation

INTERNATIONAL STANDARD

001: 2007 CEB STANDARD

COMMERCIAL ITEM DESCRIPTION SPLICE CONNECTORS

EE 340 Transmission Lines

L1-CHE-SPE-273 SIGNALLING AND COMMUNICATIONS CABLE APPLICATION GUIDELINES

Earthing Requirements for HV Transmission Structures

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201

Transcription:

SECTION VI SCOPE OF WORK Overhead Lines and Underground cables

VI 5.2 - i TABLE OF CONTENTS 5.2 SCOPE OF WORKS... 1 5.2.1 General... 1 5.2.2 Factory Acceptance Test... 2 5.2.3 33KV Lines and Cables... 3

Kenya Power and Lighting Co X 5.2-1 Contract A39 5.2 SCOPE OF WORKS 5.2.1 General The Bidder shall examine the scope of works in this section in close connection with the other documents and particulars forming these Bidding Documents. Special attention shall be paid to Technical Specifications, in which the general technical requirements are specified. The drawings enclosed in are for bidding purposes only. If the Specifications and/or Drawings do not contain particulars of materials or goods that are necessary for the proper and safe completion, operation and maintenance of the equipment in question, all such materials shall be deemed to be included in the supply. In the event of any conflict between the Drawings and the Specifications, the latter shall prevail. In the event of any conflict between scaled dimensions and figures on the Drawings, the figures shall prevail. Should the Bidder find discrepancies in or omissions from these Specifications or from the other Documents, or should he be in doubt as to their meaning, he should immediately contact the Project Manager for interpretation, clarification or correction thereof before submitting his Bid. Such action shall, however, in no case be considered as a cause for altering the closing date of the Bid. The scope of work covers supply of equipment, engineering and design, manufacture, testing before shipment and packing sea worthy or otherwise as required, delivery of all equipment CIP site, construction and installation and commissioning. Where the new line share the route with existing lines, the scope of work shall include all the necessary works/modifications that will be required to accommodate the lines along the same route. The conductors of the existing lines shall be re-used while new hardware/fittings of correct type and size shall be used. The term "transfer" in this scope of works shall mean supply of new hardware/fittings, new concrete poles, stays, insulators as well as installation of these in the existing line routes. It also includes moving all equipment, such as distribution transformers, autoreclosers, switches and links, capacitor banks etc, mounted on the present poles over to the new poles. Also, all existing poles, conductors and hardware/fittings shall be recovered and handed over to the KPLC stores at locations most near to the installation sites. Cross arms: Steel cross-arms shall be used in all cases including re-conductoring. All steel cross arms shall be grounded. Conductor Joints and Termination s All joints and terminations shall be of compression type for conductors of 150mm2 and above.

Kenya Power and Lighting Co X 5.2-2 Contract A39 Shield Wires: OPGW (Optical Ground Wire) shall be used in all the 33Kv Lines. The standard size used by KPLC is 48 core fibres, where the 33KV line is done in underground cable, a Fibre Optic cable will be laid together in the trace of the cable. 5.2.2 Factory Acceptance Test The contractor shall meet the cost of travel for FAT for two (2) participants and the project manager. Accommodation and per diem cost shall be met by the employer. The following major equipment shall be offered for inspection 33kV Post Insulators OPGW and Optical distribution frames 33KV cables Line hardware FAT shall be carried out as prescribed in the particular technical specification.

Kenya Power and Lighting Co X 5.2-3 Contract A39 5.2.3 33KV Lines and Cables The scope of works includes: 33KV Feedouts from Kabarnet 132/33kV Substation Construction of a total 51km of 33kV overhead Lines in 150mm2 ACSR Conductor. All sections, joints and terminations shall be of compression type. All the above will have OPGW. For undergrounded sections of the line, underground FOC shall be installed. The insulators to be used for line construction shall be post insulator type with intermediate poles all being delta formation with earth stalk. All the lines shall be constructed in Concrete Poles apart from the following line sections that shall be done in wooden poles. 1. Sheets 11, 12, and 13 (having poles numbers P 1 to P 80) starting from the line supplying Changach Shops S/S 28144) to s/s 23997 along-kabarnet-iten Road. 2. Sheet No.3 and 4(Having Poles No.33,2x14M to Pole No 89, 2x14M) The wooden poles must meet the following specification. i. All the poles must meet the height as in the drawings provided ii. All poles must be Stout Pole type iii. They must be treated as per specification provided iv. Physical And Mechanical Properties The wood poles used shall have the following properties:- Nominal length 11 12 14 Category Stout Stout Stout H(mm) 1.8 1.8 2.0 D c (mm) 295 305 310 D m (mm) 200 200 200 D g (mm) 295 305 335 D e (mm) 234.8 238.1 248.4 F(kN) 13.05 10.37 8.23 Ultimate load (kn) 18.42 18.24 20.02 Crippling load (kn) 149.8 128.9 110.3 H d c d g d m d e f Ground position from butt Critical diameter Minimum ground line diameter (mm) Minimum top diameter (mm) Effective diameter Load per mm of deflection at point of application of load Note that the mechanical properties used in the mechanical calculations are those stated in the Kenya Standard KSO2-516. All the above described works will also include mounting of Wall Mounted Optical Distribution Frames, design, and all other works described in the document.