Lessons Learned in Model Validation for NERC Compliance

Similar documents
Lessons Learned in Model Validation for NERC Compliance

Demonstration of PFR Improvement September ERCOT Operations Planning

Uses of Synchrophasor BD NSF Workshop 2017

Reliability Considerations for PPMV. Ryan Quint, NERC Dmitry Kosterev, BPA NASPI-NERC PPMV Tools Workshop October 2016

Reliability Guideline

Generator Parameter Validation (GPV)

Operationalizing Phasor Technology. Model Validation. Webinar. Ken Martin. March 4, Presented by. Page 0

Unit Auxiliary Transformer (UAT) Relay Loadability Report

Indication of Dynamic Model Validation Process

Harmonizing the Changing Resource Mix Keeping the Grid Together

Generation Interconnection Study Data Sheet Synchronous Machines

Robert W. Cummings - NERC Director of System Analysis and Reliability Initiatives William Herbsleb - Chairman of Frequency Response Standard Drafting

generation greater than 75 MVA (gross aggregate nameplate rating) Generation in the ERCOT Interconnection with the following characteristics:

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

Document C-29. Procedures for System Modeling: Data Requirements & Facility Ratings. January 5 th, 2016 TFSS Revisions Clean Open Process Posting

Testing model data usability Excitation Systems PSS Limiters

Grid codes and wind farm interconnections CNY Engineering Expo. Syracuse, NY November 13, 2017

Standard MOD Verification of Models and Data for Generator Excitation Control System or Plant Volt/Var Control Functions

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

NERC / TVA STABILITY WORKSHOP

Energy-Based Damping Evaluation for Exciter Control in Power Systems

VOLTAGE STABILITY OF THE NORDIC TEST SYSTEM

Modeling of Three-phase or Bank of Three Single Phase Three Winding Transformers Zero-phase-sequence Leakage Impedance in PSS E Short Circuit Module

Setting and Verification of Generation Protection to Meet NERC Reliability Standards

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

Generation and Load Interconnection Standard

Generation and Load Interconnection Standard

Standard MOD Verification of Models and Data for Generator Excitation Control Sys tem or Plant Volt/Var Control Functions

Synchrophasor Technology PMU Use Case Examples

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction. See the Implementation Plan for PRC

Jonathan (Xiangmin) Gao - GE Grid Solutions Douglas Rust - Dandsco LLC Presented by: Tom Ernst GE Grid Solutions

Endorsed Assignments from ERS Framework

Sarma (NDR) Nuthalapati, PhD

Industry Webinar. Reactive Power Planning. NERC System Analysis and Modeling Subcommittee (SAMS) March 2017

How Full-Converter Wind Turbine Generators Satisfy Interconnection Requirements

Frequency Response Initiative Industry Advisory Generator Governor Frequency Response

( ) Regional Reliability Standard ( ) Regional Criteria ( ) Policy (X) Guideline ( ) Report or other ( ) Charter M&VWG. Web URL:

Synchrophasor Technology at BPA: from Wide-Area Monitoring to Wide-Area Control

Forward Looking Frequency Trends Technical Brief ERS Framework 1 Measures 1, 2, and 4: Forward Looking Frequency Analysis

Imperial Irrigation District System Planning ATTACHMENT A

Response of Grid Interconnected Solar PV inverters to Transmission System Faults

Final ballot January BOT adoption February 2015

FACILITY CONNECTION REQUIREMENTS

Wind Power Facility Technical Requirements CHANGE HISTORY

Initial Application Form for Connection of Distributed Generation (>10kW)

H6e - Hydro Turbine-Governor Model

Facility Interconnection Requirements for Colorado Springs Utilities Version 03 TABLE OF CONTENTS

NARUC. Summer Committee Meetings. Staff Subcommittees on Electricity & Electric Reliability

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Meeting Notes Project 2016-EPR-02 September 7-9, 2016

NERC Protection Coordination Webinar Series June 23, Phil Tatro

EASING NERC TESTING WITH NEW DIGITAL EXCITATION SYSTEMS

Kestrel Power Engineering

System Protection and Control Subcommittee

Power Plant and Transmission System Protection Coordination

Operational Modeling and Model Inputs

Wind Requirements and Testing for Steady-State Voltage and Frequency Control

Overview of Synchrophasor Applications. Dmitry Kosterev Bonneville Power Administration

Experience from Tests of Frequency Containment Reserve delivery for Generating Units

Wide-Area Monitoring and Control of Power Systems using Real-Time Hardware-in-the-Loop Simulations

EXCITATION SYSTEM MODELS OF GENERATORS OF BALTI AND EESTI POWER PLANTS

Power Plant and Transmission System Protection Coordination

Real Time Stability Analysis at Peak Reliability. Slaven Kincic, Hongming Zhang JSIS May 2017, SLC

SDG&E Transmission Synchrophasor Project Update

Transmission Interconnection Requirements for Inverter-Based Generation

Synchrophasor Solutions Deployment at PG&E Off-Line Analysis

Attachment B to Primary Frequency Response Reference Document Sustained Primary Frequency Response Methodology for BAL-001-TRE-1

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

Interconnection-Wide Oscillation Analysis: Baselining Oscillation Modes in the North American Power System Objective Purpose

An Introduction to Completing a NERC PRC-019 Study for Traditional and Distributed Generation Sources

MANITOBA HYDRO TRANSMISSION SYSTEM INTERCONNECTION REQUIREMENTS. April 2009 Version 2

Generator Voltage Protective Relay Settings

WECC Data Preparation Manual

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Application Of Power System Stabilizer At Serir Power Plant

Industry Webinar Draft Standard

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

DER_A Benchmark Update

Standard VAR b Generator Operation for Maintaining Network Voltage Schedules

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

TECHNICAL SPECIFICATIONS AND OPERATING PROTOCOLS AND PROCEDURES FOR SMALL GENERATION INTERCONNECTIONS

Analysis of Effect on Transient Stability of Interconnected Power System by Introduction of HVDC Link.

WECC Data Preparation Manual

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section SCADA Technical and Operating Requirements

MANITOBA HYDRO TRANSMISSION SYSTEM INTERCONNECTION REQUIREMENTS. July 2016 Version 4

No I am concerned about units that may be individually less than 20 MVA but collectively could eb much larger - wind farms. Yes

EE 742 Power System Components. Y. Baghzouz ECE Department UNLV

Study of Frequency Response in Power System with Renewable Generation and Energy Storage

Course ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation

Integration of Variable Renewable Energy

Wind Power Plants and future Power System Frequency Stability

IJSER. Fig-1: Interconnection diagram in the vicinity of the RajWest power plant

Texas Reliability Entity Event Analysis. Event: May 8, 2011 Loss of Multiple Elements Category 1a Event

ReliabilityFirst Regional Criteria 1. Disturbance Monitoring and Reporting Criteria

NERC Training Document Understand and Calculate Frequency Response

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section SCADA Technical and Operating Requirements

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

Transcription:

Lessons Learned in Model Validation for NERC Compliance usa.siemens.com/digitalgrid

NERC Modeling, Data, and Analysis MOD 025 2: Generator Real and Reactive Power Capability Demonstration MOD 026 1: Verification of Models for Generator Excitation Control Systems MOD 027 1: Verification of Models for Turbine/Governor and Load Control Functions, including validation of turbine droop and determination of governor s deadband Page 2

Unit Size for NERC Model Validation Requirement (MVA) ERCOT Eastern Interconnection WECC Individual Unit Plant Individual Unit Plant Individual Unit Plant MOD-25-2 >20 >75 >20 >75 >20 >75 MOD-26-1 >50 >75 >100 >100 >75 >75 MOD-27-1 >50 >75 >100 >100 >75 >75 Page 3

Siemens PTI Services Onsite technical assistance for performing the tests Field tests data processing Model validation (PSS E/PSLF) Verification of generator OC excitation curve and generating unit inertia constant Adjustment of controllers parameters AVR and PSS tuning Over- and Under-excitation limiter adjustment V/Hz limiter adjustment Development of user-written models Page 4

MOD-025-2 Generator Tests Estimated and Operating capability curve (D-curve) Page 5

MOD-025-2 Generator Tests Measurements: Active & reactive power, voltage at unit terminals (point A) Active & reactive power, voltage at the high voltage side of the GSU (point F) Active & reactive power through the high voltage side of the auxiliary transformer (point B) Voltage at the low voltage side of the tertiary winding (point C) Active and reactive power at the high voltage side of the GSU of the other units (point D) Page 6

MOD-026-1 Generator Excitation Control System Model Verification Open-circuit dynamic response calibration Interconnected dynamic performance calibration Validate model parameters by comparing field test records against current PSS E or PSLF dynamic models Page 7

MOD-026-1 Generator Excitation Control System Model Verification Open-circuit dynamic response calibration Interconnected dynamic performance calibration Validate model parameters by comparing field test records against current PSS E or PSLF dynamic models Page 8

MOD-027-1 Turbine/Governor and Load Control Functions Model Verification Validation of the speed governor response for an on-line perturbation test with synthetic speed signal of ±0.2Hz Page 9

Power Plant Model Validation using PSS E Playback Model usa.siemens.com/digitalgrid

PSS E Playback Model PLBVFU1 Overview The PLBVFU1 model plays back a known set of voltage and frequency signals The PLBVFU1 model acts as a generator model (with no excitation system or turbine-governor models) The played-in voltage and frequency signals must be included in a data input file Page 11

PSS E Playback Model Playback Model for Voltage Signal Page 12

PSS E Playback Model Playback Model for Frequency Signal Page 13

PSS E Playback Model Playback Model Example Test System Unit to be tested Playback generator Page 14

PSS E Playback Model Playback Model PMU data vs. PSS E simulation results Page 15

Contact Us Carlos Grande-Moran Principal Consultant Siemens Power Technologies International E-mail: carlos.grande@siemens.com Dinemayer Silva Staff Consultant Siemens Power Technologies International E-mail: dinemayer.silva@siemens.com usa.siemens.com/digitalgrid Page 16