Glass Systems Technical Information on Profiled Glass with System - English Edition -
The - Delivery Programme Glass thickness 6 mm, flange height mm 6 7 0 K 3 8 K//7 3 6 7 6 6 6 6 6 6 50 39 486 K5 6 K3 33 K50 498 Glass thickness 7 mm, flange height mm 7 7 48 K5//7 6 7 7 37 K3//7 33 7 7 48 K5//7 Wave 6 6 6 50 K5 Wave 6 d l b Cross-section d d h l b d h Tolerances: b ±.0 mm d ± 0. mm h ±.0 mm Cutting tolerances of ± 3.0 mm are allowed. Tolerances according to EN 57-7. Dimensions are nominal. For the application of the relevant national and international requirements and standards have to be considered in the various countries. Dimensions types K K5 K3 K50 K5 K5//7 K//7 K5//7 K3//7 Wave Wave Width b (mm) 3 6 33 498 6 3 6 33 6 Flange height h (mm) Glass thickness d (mm) 6 6 6 6 6 7 7 7 7 Weight (single glazing) kg/m 9.5 9 8. 7 9 5.5 4.5.5 4.5 max. supply length Lmax (mm) (not max. installation length) 00 00 00 5000 00 7000 7000 7000 7000 with wires Number of longitudinal wires 7 8 0 6 8 7 8 0 8 6 longitudinal wires - - - - - - - (mesh function) * 8+ wires * - - - - - - - - functional glass Colours / Patterns / Design thermally toughened Plus.7 (heat insulating glass, low-e) Plus.7 Wire (heat insulating glass, low-e) Antisol (sun-protection glass) Antisol Wire (sun-protection glass) Amethyst Amethyst Wire Clear (without ornament) * - - - - - Clear Wire (without ornament) * - - - - - - Micro * - - - - - Macro * - - - - - Slim Line * - - - - - Opal OW (low iron) * T, * thermally toughened, with or without heat-soak test T Color, thermally toughened and coloured enamelled, with or without heat-soak test Production standard Production optional * with coating available (Amethyst, Antisol, Plus.7) without CE-marking Lmax = 4.5 m Subject to change. Sale from stock providing there are sufficient stocks available or from next production run. We would be pleased to examine the possibility of supplying any product combination not mentioned above upon request. Product specifications are available upon request.
Standard max. installation lengths for vertically installed glazing panels sealed and not inclined Single glazing (flange inside) Design K5 K5//7 wind load K K5 K3 K50 K//7 K5//7 K3//7 Wave Wave kn/m L (m) L (m) L (m) L (m) L (m) L (m) L (m) L (m) L (m) 0.50.70.50.30.90.50 4.0 4.00 3. 4.00 0..40.30.00.70.30 3.85 3. 3.30 3. 0.70.30.0.90..0 3.55 3.40 3.00 3.40 0.80.0.00.80.50.00 3.35 3.0.85 3.0 0.90.00.90.70.40.90 3.0.95.70.95.00.90.80..30.80 3.00.80.55.80.0.70..50.0..70.55.30.55.40..50.35.0.50.50.40.5.40..50.40.5.00.40.35.0.00.0.80.40.30.0 0.95.30.0.0.90.0.00.30.0.0 0.90.0.0.00.80.00 3.00.00.00 0.90 0.75.00.70..45. Double glazing Design K5 K5//7 wind load K K5 K3 K50 K//7 K5//7 K3//7 Wave Wave kn/m L (m) L (m) L (m) L (m) L (m) L (m) L (m) L (m) L (m) 0.50 3.80 3. 3.0.70 3. 6.00 5.70 5.0 5.70 0. 3.40 3.5 3.00.40 3.5 5.40 5.5 4.65 5.5 0.70 3.0 3.00.70.5 3.00 5.00 4.75 4.30 4.75 0.80 3.00.80.55.0.80 4.70 4.50 4.00 4.50 0.90.80.70.40.00.70 4.40 4.0 3.80 4.0.00.65.50.30.90.50 4.0 4.00 3. 4.00.0.55.40.0.80.40 4.05 3.80 3.45 3.80.0.40.30.00.70.30 3.80 3. 3.30 3..40.5.0.90..0 3.50 3.40 3.00 3.40..0.00.75.45.00 3.30 3.5.80 3.5.80.00.90.65.35.90 3.0 3.00.65 3.00.00.85.75.55.30.75 3.00.80.55.80 3.00.50.40.30.00.40.40.30.00.30 Note: This table gives standard installation lengths in metres, for vertically installed glass within closed buildings and should be used as a guide only. However the local national regulations referring to safety parameters still have to be taken into account. For Opal the same installation lengths as for the corresponding standard products apply. For other applications or for any question please feel free to address the manufacturer s technical service department. 3
- Standard vertical glazing Single and double shell glazing single shell Vertical section - double shell frames with thermal insulation N 950 N 96/ top and side frame N 950 Pilkington Profilit SIL top and side PVC profile N 96/ N 80 N 96/ bottom PVC profile N 96/ breastwork N 96 bottom frame N 96/50 View drainage slit for condensation water N 8 drainage slit for condensation water (offset) overhang N 96/00 with integrated window sill N 96 separate window sill arrangement N 8/50 width of window sill Horizontal section - Single shell glazing SIL N 96/ N 96/ N 950 N 80 Double shell glazing gasket N 66 (optional) SIL N 96/ N 950 Note: The following pages 4-8 show illustrations of standard applications for which profiled glass can be used. 4 In view of the wide range of application options for of which the details however cannot be shown here, please contact our applications technology department for any further advice.
- Special vertical glazing for sport halls Double shell glazing For sport halls see test certificate according to DIN 803 part 3 Vertical section - frames with thermal insulation top and side frame N 980 top and side PVC profile N 980/ N 80 breastwork.00 m bottom PVC profile N 98/ bottom frame N 98 View drainage slit for condensation water N 8 possible for glass types K //7, K 5//7, K 3//7 drainage slit for condensation water (offset) N 98/50 N 98/00 N 8/50 Horizontal section - Double shell glazing N 980/ N 66 N 65 top and side frame N 980 N 80 gaskets N 65 + 66 5
- Installation of ventilation shutters installation system with ventilation shutter unit The installation system is a modular system essentially comprising the following elements: High-quality aluminium profiles - available as mill finished, anodised, RAL coated or thermally insolated options Plastic insert or support profiles - high impact resistance, light resistance, weatherproof and non warping Ventilation elements - standard sizes or made to order; marry perfectly with the installation system, also available as thermally insulated option 3 3 4 4 Isoglazing or Pilkington Profilit h = outer height of wing unit View installation with H-bars h = outer height of wing unit Note: Reinforcement is also required when ventilation shutter is fitted to the basic frame. If applicable, the H-frames should be checked to ensure they are sufficiently stable. Vertical section - Vertical section - Horizontal section 3-3 Horizontal section 4-4 6
- Standard horizontal glazing Double shell glazing Section - N 950 joint between the glass panes: approx. 8 mm (thereof -3 mm space between glass and support angle below) N 96/ breastwork support angle with padding for each glass unit View N 96/ N 96/80 Note: different glass types require structurally designed support angles support angle with padding to separate glass from metal (by customer) frames with thermal insulation N 984 N 884 Section - N 964 N 864 support angle (fixing with Halfen-screws) 7
- Roof glazing (vertical shed glazing) Double shell glazing System sketch roof material aluminium screen N 963w gasket round cord Profilit SIL substructure according to structural design isolating layer installation tape with core wired N 940w additional sheeting as required drainage slit installation tape with core substructure according to structural design roof joint sealing foil Note: No details concerning roof joints, heat-insulating measures, etc. are given here. 8 The drainage slits for condensation water made by customers are depending on the fixing of the frames and the inclination of the glazing. Max. frame loading in case of vertical installation (e.g. non bearing facades) - double layer - due to weight of glass l 3.50 m! Max. interval between bolts of 0 cm. In case of thermal broken frame N 940w l 3.00 m.
- Product characteristics Heat insulation, Solar control and Light transmission: Product combination U G value g value Light transmission [W/m K] [ - ] [%] single glazed 5.7 0.79 86 double glazed without coatings.8 0.68 75 double glazed outer shell uncoated.8 0.63 70 inner shell Plus.7 double glazed outer shell Antisol.8 0.49 43 inner shell uncoated double glazed outer shell Antisol.8 0.45 inner shell Plus.7 double glazed outer shell Amethyst.8 0.46 40 inner shell Amethyst double glazed outer shell Amethyst.8 0.49 5 inner shell Plus.7 triple glazed outer shell 7 mm uncoated middle 7 mm Plus.7 inner shell 6 mm Plus.7. 0.5 5 U G value according to EN 673, g value and light transmission according to EN 0. Physical properties for further product combinations are available upon request. Heat insulation- and solar control characteristics can be further improved by using e.g. triple glazed options or with translucent insulation materials. Noise control: Product combination double glazed without gaskets double glazed with gaskets no. 65 and no. 66 triple glazed R W value [db] up to db up to 43 db up to 57 db Noise control values tested in system according to EN ISO 40-3. Further information and product combinations upon request. Ball impact safety: Product combination K//7, K5//7 or K3//7 double glazed with gaskets no. 65 and no. 66 T-H K//7, K5//7 or K3//7 double glazed with gaskets no. 65 and no. 66 Ball impact safety tested with handball tested with handball and hockeyball Ball impact safety tested according to DIN 803-3. Please take into consideration special installation guidelines for sports hall glazing. Note: Further product- and system characteristics (e.g. regarding safety or weather tightness) can be provided upon request. Please contact our Application Technology Department. 9
- Installation components - 6 mm glass types - 7 mm glass types 6 0 K 3 6 6 6 50 K5 6 6 6 486 K50 498 6 6 39 K3 33 6 6 50 K5 Wave 6 7 8 K//7 3 7 7 7 48 K5//7 Wave 6 7 7 48 K5//7 6 7 7 37 K3//7 33 - Accessories - Aluminium and plastic sections, series (NP) - Aluminium and plastic sections, series 83 (SP) 950 N 950 S 80 980 80 96/ 980/ 950 SL 96 8 98 8 95 96/50 8/50 96/N 98/50 8/50 980/ 96/80 8/80 96/A 98/00 8/80 98/ 96/ 96/00 8/00 8/00 98/ 96/ 96/0 8/0 8/0 98 D 96 D 96/50 8/50 8/50 96/80 8/80 950 D 978 8/80 980 D 977 964 8 864 984 8 884 - Gaskets - Special profiles 65 66 70 - Window sills 930 930w 940 940w 963 963w 98 97/30 97/50 96/00 D 96/0 D 97/30 D 96/50D 96/80D 98w 973/80 96/50 D 936 936w 965 965GT 965 GT/D 976 973/0 96/80 D 973/0 D 974 0 93 93w 934 934w 93 983k 983 973/40 973/40 D 96 K
profiles series (NP) profiles series 83 (SP) non thermally thermally non thermally thermally profile description broken broken broken broken 950 N 80 980 80 Top and side frame 950 S - - - Top and side frame 950 SL - - - Top frame with integrated ventilation 96 8 98 8 Bottom frame with drainage slits 95 - - - Bottom frame (interior glazing e.g. for partitions) 96/50 8/50 98/50 8/50 Bottom frame with integrated 50 mm window sill with drainage slits 96/80 8/80-8/80 Bottom frame with integrated 80 mm window sill with drainage slits 96/00 8/00 98/00 8/00 Bottom frame with integrated 00 mm window sill with drainage slits 96/0 8/0-8/0 Bottom frame with integrated 0 mm window sill with drainage slits 96/50 8/50-8/50 Bottom frame with integrated 50 mm window sill with drainage slits 96/80 8/80-8/80 Bottom frame with integrated 80 mm window sill with drainage slits 977 8 978 8 H-bar for mounting windows 964 864 984 884 Side frame for horizontal glazing - PVC inlay profiles 96/ 980/ Top and side inlay profile for single glazing 96/N 980/ Top and side inlay profile for double glazing 96/A - Top and side inlay profile for installation inside a ventilation shutter for double glazing 96/ 98/ Bottom inlay profile for single glazing 96/ 98/ Bottom inlay profile for double glazing 96 D - 98 D - Expansion joint profile for bottom frames 950 D - 980 D - Expansion joint profile for top and side frames - Gaskets and sealing profile 65 Gasket for glass flanges, double 66 Gasket for glass flanges, single 70-70 - Sealing profile for frames with integrated window sill no. 96/50.../80, 98/50 and 98/00 - Window sills (separately) 97/30 Window sill profile 30 mm for bottom frames no. 96, 98, 8, 8 97/50 Window sill profile 50 mm for bottom frames no. 96, 98, 8, 8 973/80 Window sill profile 80 mm for bottom frames no. 96, 98, 8, 8 973/0 Window sill profile 0 mm for bottom frames no. 96, 98, 8, 8 973/40 Window sill profile 40 mm for bottom frames no. 96, 98, 8, 8 974 Rim profile for window sills 96 K PVC clamp profile no. 96 K for the connection of the window sill with the bottom frames no. 96, 98, 8, 8 - Expansion joint profiles for window sills 96/50 D Expansion joint profile for window sill 50 mm 96/80 D Expansion joint profile for window sill 80 mm 96/00 D Expansion joint profile for window sill 00 mm 96/0 D Expansion joint profile for window sill 0 mm 97/30 D Expansion joint profile for window sill 30 mm 96/50 D Expansion joint profile for window sill 50 mm 96/80 D Expansion joint profile for window sill 80 mm 973/0 D Expansion joint profile for window sill 0 mm 973/40 D Expansion joint profile for window sill 40 mm - Special profiles 965 - - - Door frame suitable for wooden and metal doors 965 GT - - - Door frame suitable for glass doors 965 GT D - - - Sealing for door frames no. 965 and no. 965 GT 930 930w - - Side frame for transparent glazing with insulating glass 93 93w - - Top and bottom frame for transparent glazing with insulating glass 93 93w - - Aluminium clip strip for insulating glass up to 4 mm thickness 934 934w - - Connection profile between top and bottom frame (series ) and window casments 936 936w - - Double bar for transparent glazing with insulating glass - - 983 - Latch-bolt profile - - 983k - Clamp profile for profile no. 983 to reduce the width of the frame from 83 mm to mm 940 940w 98 98w Bottom shed glazing profile for double glazing 963 963w - - Top shed glazing profile for double glazing 976-976 - Connection angle The recommendations for tendering in German and English are available as download (WORD- or PDF file) on the homepage www.pilkington.com (www.profilit.com).
This publication provides only a general description of the product. Further, more detailed information may be obtained from your local Pilkington Building Products supplier. It is the responsibility of the user to ensure that the use of this product is appropriate for any particular application and that such use complies with all relevant legislation, standards, code of practice and other requirements. To the fullest extent permitted by applicable laws, the companies of NSG Group disclaim all liability for any error in or omission from this publication and for all consequences of relying on it. Products according to valid delivery program. Subject to change. Pilkington is a trade mark of NSG Group. CE marking confirms that a product complies its relevant harmonised European Norm. The CE Marketing label for glass products, including declared values, can be found at www.pilkington.com/ce. Bauglasindustrie GmbH Hüttenstraße 33 66839 Schmelz Phone +49 (0)6887 303 0 Fax +49 (0)6887 303 45 E-Mail profilbauglas@nsg.com www.pilkington.com Issue date: 0/0 English V.0