TELEPHONE: (215) Addendum No. 1

Similar documents
ADDENDUM NO. 3. Ellis County Elections Building

December 31, 2015 A. THE BID OPENING DATE IS UNCHANGED. B. Questions, Additions, and Deletions

RENOVATION TO STUDENT SERVICES/HOUSING FROM HOSPITAL DAKOTA STATE UNIVERSITY MADISON, SOUTH DAKOTA

Notre Dame High Addition/Renovation Addendum 3 Page 1

FAP63T-W 1/7. FAP Strategy III Series Ceiling Loudspeaker. Features. General Description. Applications. AtlasIED.com FAP63T-W

TELEPHONE: (215) Addendum No. 01

1.01 NOTICE TO BIDDERS

RENOVATION OF THE FARMERS MARKET Reference Number:

Wayne State University. Prentis Building Renovation. NM Project Number: Niagara Murano 2215 Cole Street Birmingham, Michigan, 48009

ADDENDUM #1. April 29, 2009

ADDENDUM NO. 2. Germania Club Renovation Phase 2. Saginaw County Community Mental Health Authority WILLIAM A. KIBBE & ASSOCIATES, INC.

ADDENDUM NOTICE INTERIOR RENOVATIONS AT THE BATHURST CLARK RESOURCE LIBRARY, 900 CLARK AVENUE WEST, VAUGHAN, ON

PROJECT LOCATION BOZEMAN HIGH SCHOOL. ELECTRICAL ENGINEER: Van Dykken Engineering 37 Spanish Peak Drive Bozeman, MT Phone:

OCV 6. Product Description. Features. Applications

TELEPHONE: (215) Addendum No Cooling Plant Replacement SDP Contracts No. B-080C, B-081C and B-082 of 2017/18

FreeSpace DS 16F VA TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

Distributed Design D SERIES D10 TWO-WAY 10-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

HAYES VALLEY PLAYGROUND AND CLUBHOUSE PROJECT NO.: SAN FRANCISCO PARKS AND RECREATIONS SAN FRANCISCO, CA

Distributed Design D SERIES D8 TWO-WAY 8-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Specifications: Other: sign in sheet

CLARIFICATIONS 1. See attached meeting minutes from the Pre-Bid meeting on June 14, 2017.

FAP63TC-W. Shallow Mount FAP Strategy III Series Ceiling Loudspeaker

Panaray 302 A TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications. Bose Professional Systems Division 1 OF 6

The following items are updated to reflect revisions and are hereby incorporated into the Inquiry Documents, Inquiry No. 17-WDI-031.

Distributed Design D SERIES D6 TWO-WAY 6.5-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

FAP33T-W 1/7. FAP Strategy III Series 3" Full Range Ceiling Loudspeaker. Features. General Description. Applications. AtlasIED.

SECTION PANELBOARDS

CMS 603DC PI. Technical Data Sheet

CMS 603DC. Technical Data Sheet

CMS 803DC. Technical Data Sheet

ID0.1 PALO VERDE 8000 WEST US HIGHWAY 290 AUSTIN, TX SHEET INDEX: CONTACT INFORMATION: DISCLOSURES: DOCUMENT GENERAL NOTES:

Innovative Features Each system includes a renowned AMK Coaxial loudspeaker like those already installed in hundreds of locations

IFB PAINTING AT HAYDON ELEMENTARY ADDENDUM #1

Distributed Design Series

CMS601 DC. Product Description. Features. Applications

Innovative Features Each system includes a renowned AMK Coaxial loudspeaker like those already installed in hundreds of locations

Spec Section: , Complete Elec, Comm, and Fire Alarm , Complete Elec, Comm, and Fire Alarm Data Sheets RAN/GCAN

CVS 4. Product Description. Features. Applications

City of St. Charles School District New Addition and Renovation at George M. Null Elementary School 435 Yale Boulevard St. Charles, Missouri 63301

BIRMINGHAM CITY SCHOOLS (BCS) OPERATIONAL CENTER COMPLEX: BID PACKAGE D

FAB GSE Remodel ITB Solicitation #1538 Invitation to Bid (ITB) for General Contracting Services. ADDENDUM #4 December 5, 2014

SECTION IDENTIFICATION FOR ELECTRONIC SAFETY AND SECURITY

James W. Moore, PE / Brandon D. Enevold, PE / Kjersten E. Kuhta, PE Dylan J. Cunningham, PE / Jacob L. Deering, PE / Joel R.

Montclair, NJ ADDENDUM NO. 1 Issue Date: May 15, 2017

Panaray 620M TECHNICAL DATA SHEET. multi-position floor monitor. Key Features. Product Overview. Technical Specifications

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

CMS 603DC BM. Optimised for Installation

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

COUNTY OF NORTHUMBERLAND Addendum No. 3 Request for Quotations To Renovate the Grafton Recreation Centre for a Licensed Child Care Centre

ADDENDUM 1. This Addendum forms part of and modifies Proposal Documents dated, October 31, 2018, with amendments and additions noted below.

12560 W. Cedar Drive Lakewood, CO Barry Himmelman President

COVER SHEET A0.1 A0.1 COVER SHEET A1.1 FLOOR PLANS - FOUNDATION & MAIN LEVEL A1.2 FLOOR PLANS - UPPER LEVEL & ROOF A3.1 SECTIONS & INTERIOR ELEVATIONS

SAN FRANCISCO UNIFIED SCHOOL DISTRICT 2011 PROPOSITION A BOND PROGRAM SOTA-AAS HIGH SCHOOL MODERNIZATION ADDENDUM NO. 2

Company. Signed: Date:

Panaray MB4 TECHNICAL DATA SHEET. modular bass loudspeaker. Key Features. Product Overview. Technical Specifications

ATHENS TCS52C-T-WH # #

Self-Amplified Horn Speakers

TG Glazing Design-Build

03/7/12 Issuance UTD Section Page 1 of 5 Electrical General

CMS601. Product Description. Features. Applications

ADDENDUM NO. 1 November 10, 2016

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SUPERIOR COURT OF CALIFORNIA NORTH BUTTE COUNTY COURTHOUSE JBCP201205BR ADDENDUM NO. 5. February 25, 2013

Bid No. B14-02 Building 100 HVAC Improvements

Addendum. Windsor Hall Renovations Date: October 12, 2017 Addendum No: 3 GENERAL. 1! Addendum #4 will be issued 2:00 PM Tuesday October 17, 2017.

ACME 50 Application Guide

EVID High Performance Ceiling Speakers

POST BID ADDENDUM TWO

Install Speakers. 2 Way 3.5" Full Range Ceiling Loudspeaker with Line Transformer for Installation Applications (White)

SECTION PROJECT MANAGEMENT AND COORDINATION

HAMMEL ASSOCIATES ARCHITECTS, LLC 2 5 E A S T G R A N T S T R E E T, S U I T E L A N C A S T E R, P E N N S Y L V A N I A

TELEPHONE: (215) Addendum No New Solomon Solis-Cohen Elementary School SDP Contracts No. B-075C, B-076C, B-077C and B-078C of 2017/18

FreeSpace DS 40F flush-mount loudspeaker

SECTION 10520: FIRE EXTINGUISHERS AND CABINETS

ADDENDUM NO. 3 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030

4. Special Systems Design: including Fire Alarm and Security. C. Electrical and Telecommunications Ductbanks: Refer to Section 16118

This section describes the design requirements and materials/products for door hardware.

CVS 6 # # Exceptional Sound and Reliability

HOENER ASSOCIATES INC. ARCHITECTS

CMS401e. Product Description

2. Electrical rooms shall be centrally located and stacked so that feeder conduits and bus duct are run as straight and short as possible.

FAP33T-W 1/8. FAP Strategy III Series 3" Full Range Ceiling Loudspeaker. Features. General Description. Applications. AtlasIED.

ALL PLAN HOLDERS NANCY MAGER, NPSR ARCHITECTS, INC. DATE: November 29, Lea County General Service Building PROJECT NO: ADDENDUM NO: 1

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

B. The designated coverage areas shall include both indoor and outdoor coverage.

Project No: Date: 02 September To: The Des Plaines Public Library Issued by: Lisa Schmidt

The CMS 1201DC is a full bandwidth 800-Watt high sensitivity loudspeaker

The following information supplements and/or supersedes the bid documents issued on July 10, 2017.

FreeSpace DS 16SE TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

To the Drawings and/or Specifications for. Board of Education of Harford County Lancaster, PA 17603

Locks. General Information KEYWAYS STANDARD CORE INTERCHANGEABLE CORE CONSTRUCTION INTERCHANGEABLE CORES KEYING KEYWAYS KEYING KEYS KEYS

INVITATION TO TENDER ITT No. PS FIRE HALL 5 + HOUSING CONSTRUCTION. ADDENDUM No. 2 and AMENDMENT No. 2

Chuck Caesar. VIA: /Webposting April 27, 2017

PA OF of 6 PAGES PA121 SPEAKER. Vision Series

Description of Changes ADDENDUM NO. 7

PROCUREMENT SERVICES th St, SW Calgary, AB T2R 0L4 Telephone: (403) Fax: (403)

PA OF of 6 PAGES PA151 SPEAKER. Vision Series

(Full legal name of business submitting the offer)

SECTION PROJECT COORDINATION VIA BIM

Transcription:

THE SCHOOL DISTRICT OF PHILADELPHIA SCHOOL REFORM COMMISSION Office of Capital Programs 440 North Broad Street, Third Floor - Suite 371 Philadelphia, PA 19130-4015 TELEPHONE: (215) 400-4730 Addendum No. 1 Subject: LOUIS H. FARRELL ELEMENTARY SCHOOL CLASSROOM MODERNIZATION SDP CONTRACT NOS. B-029 C, B- 031 CC Location: LOUIS H. FARRELL ELEMENTARY SCHOOL 8300 Castor Avenue Philadelphia, PA 19152 This Addendum, dated 9 th of May 2018, shall modify and become part of the Contract Documents for the work of this project. Any items not mentioned herein, or affected by, shall be performed strictly in accordance with the original documents. 1. Bids are due on Monday 14 th May at 10 a.m. 2. The successful bidder is required to attend a de-scoping meeting the following day after bids are due. The time for this meeting will be communicated on the bid opening day. 3. Deadline for questions has passed; no more new questions will be received. 4. Drawings Revised by Narrative Note drawing text deletions are shown with strikethrough, drawing text additions are shown in bold a. E001: GENERAL DEMOLITION NOTES: Note 16 shall be revised to read as follows: 16. IT IS INTENDED THAT ALL NON-OPERATIONAL SURFACE BOXES, CONDUIT AND CABLE BE REMOVED. ALL ASSOCIATED WIRING TO BE REMOVED. BOXES AND CONDUIT EMBEDDED IN CONCRETE OR WALLS MAY REMAIN, CONDUIT TO BE CUT AT WALL BOUNDARY, BOXES TO BE COVERED WITH A STAINLESS STEEL BLANK COVER. Note 18 shall be added as follows: 18. ALL EXISTING TO REMAIN WIRING ASSOCIATED WITH EXISTING SPEAKERS, TELEPHONE, DATA AND RECEPTACLES SHALL REMAIN AND MAINTAIN IN WORKING CONDITION. ANY WIRING IF DAMAGED AND/OR CUT DURING THE PERFORMANCE OF THIS CONTRACT SHALL BE REMOVED AND REPLACED IN ITS ENTIRETY FROM TERMINATION TO TERMINATION. NO SPLICING OF THE OLD WIRING SHALL BE PERMITTED. THE CONTRACTOR SHALL BE RESPONSIBLE TO TEST AND VERIFY FULL FUNCTIONALITY OF ALL EQUIPMENT IN THE ROOM.

b. E001: GENERAL NEW WORK NOTES: Note 19 shall be revised to read as follows: 19. Existing Wireless Master Clock in New Addition shall be existing to remain and be extended to support new wireless clocks in classrooms as shown on the drawings. c. ED101 and ED102: ELECTRICAL KEYNOTES: Key note number 3, under Electrical Key Note on all demolition drawings, shall read as follows: DISCONNECT & REMOVE UNUSED TELEPHONE JACKS (FIELD VERIFY) AND CAP EXISTING WIRING IN WALL AND PATCH TO MATCH ADJACENT SURFACE. REFER TO ARCHITECTURAL DRAWINGS & FIELD VERIFY TELEPHONE IS FUNCTIONING AND IF NOT THEN REPLACE WITH A NEW TELEPHONE (FURNISHED BY SDP). TEST WIRING AND REPLACE AND PROGRAM THE TELEPHONE AS REQUIRED TO MAKE THE TELEPHONE FULLY FUNCTIONAL. 5. Drawing Sketches Issued (11 x 17 3 Total) ASK-E1 ASK-E2 ASK-P1 LIGHTING FIXTURE SCHEDULE ELECTRICAL PANEL SHROUD DETAIL FIRST FLOOR PLUMBING PART PLAN 6. Schedules Issued (1 Total) Append to the Hardware Specification the Schedule of Door Hardware as issued in this Addendum. 7. Questions and Clarifications.1 Question: Due to the scope of work for all projects, the substantial completion date is unachievable. Along with lost time for moving of furniture and equipment before start of project. Can the date for substantial completion be extended? Response: No.2 Question: Visual Display Surfaces - in spec there is a note if new boards are not installed in time, to use temporary boards as necessary, how many temporary boards are we to provide per classroom? Response: Temporary boards do not need to be provided..3 Question: Do we need to provide temporary window shades, if new ones are not installed before start of school? Response: No. Existing shades are to be removed and salvaged/protected and reinstalled until new shades can be installed. PAGE 2 OF 3

.4 Question: Have you checks on the choices of accent colors for the VCT tile? The colors may be a stock color, but do they have enough on hand, if not they may not be readily available for the substantial completion date. Response: Armstrong has been made aware of this project and its approximate square footage needs. Contractor to provide updated information on each color s availability immediately after NTP..5 Question: Can you please include and spec for electrostatic painting. Response: See Electrostatic Paint spec in Addendum #2..6 Clarification: The EC shall remove and dispose of all equipment identified to be removed/demolished under his scope of work..7 Clarification: DWG. E501 DATA RISER DIAGRAM: The contractor is responsible from classroom termination to patch panel termination. Contractor is also responsible for testing each new cable for proper connectivity and LABELING each and every new cable with classroom number and closet number. SDP is responsible for all network switching equipment within the closets and patching in that equipment to the new panels..8 Clarification: The lighting fixture schedule is expanded to include equivalent fixtures available through two lighting manufacturer representatives, Diversified Lighting Associates and Penn Lighting Associates. See schedule in sketch ASK-E1 issued as part of this Addendum. All fixtures listed are part of quick ship programs..9 Clarification: Application has been made to L&I for building permit..10 Clarification: Where EC is to replace non-functioning speakers and wall telephones the EC shall provide the speakers (see attached cut sheet). SDP will furnish new telephone handsets for installation by EC..11 Clarification: For rows of linear pendants using 8 ft fixtures is acceptable. Contractor may also use 4 ft fixtures to complete the runs. END OF ADDENDUM NO. 1 NARRATIVE. REFERENCED SKETCHES, SCHEDULE, AND EQUIPMENT CUT FOLLOW. PAGE 3 OF 3

CLASSROOM 100 1238 SF LOUNGE 105 CLASSROOM 101 1236 SF LOUIS H. FARRELL ELEMENTARY SCHOOL CONTRACT B- 029 C, B- 031 C SPEC. No. TYPE No. 203 B- 029 C, B- 031 C 8300 CASTOR AVENUE - CL ASSROOM MODERNIZATION - SCHOOL DISTRICT OF PHILADELPHIA LOCATION No. 35A1 FILE No. P101 5/9/2018 1 SHEET REFERENCED REVISION No. DATE FIRST FLOOR PLUMBING PART PLAN DESCRIPTION THE SHEWARD PARTNERSHIP IN ASSOCIATION WITH PRINCETON ENGINEERING SERVICES, PC DRAWING NO. ASK-P1

LOUIS H. FARRELL ELEMENTARY SCHOOL CONTRACT B- 029 C, B- 031 C SPEC. No. TYPE No. 203 B- 029 C, B- 031 C 8300 CASTOR AVENUE - CL ASSROOM MODERNIZATION - SCHOOL DISTRICT OF PHILADELPHIA LOCATION No. 35A1 FILE No. E001 1 5/9/2018 SHEET REFERENCED REVISION No. DATE COVER SHEET DESCRIPTION THE SHEWARD PARTNERSHIP IN ASSOCIATION WITH PRINCETON ENGINEERING SERVICES, PC DRAWING NO. ASK-E1

1 E001 ELECTRICAL PANEL SHROUD DETAIL SCALE: NONE LOUIS H. FARRELL ELEMENTARY SCHOOL CONTRACT B- 029 C, B- 031 C SPEC. No. TYPE No. 203 B- 029 C, B- 031 C 8300 CASTOR AVENUE - CL ASSROOM MODERNIZATION - SCHOOL DISTRICT OF PHILADELPHIA LOCATION No. 35A1 FILE No. E001 1 5/9/2018 SHEET REFERENCED REVISION No. DATE COVER SHEET DESCRIPTION THE SHEWARD PARTNERSHIP IN ASSOCIATION WITH PRINCETON ENGINEERING SERVICES, PC DRAWING NO. ASK-E2

LOUIS H FARRELL ES PHILADELPHIA, PA SECTION 087100 DOOR HARDWARE 4.1 DOOR HARDWARE SETS A. The hardware sets represent the design intent and direction of the owner and architect. They are a guideline only and should not be considered a detailed hardware schedule. Discrepancies, conflicting hardware and missing items should be brought to the attention of the architect with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application and functionality. B. Manufacturer s Abbreviations: 1. MK - McKinney 2. RO - Rockwood 3. YA - Yale 4. RU - Corbin Russwin 5. RF - Rixson 6. NO - Norton Hardware Sets Doors: A2B, A6-B Set: 1.0 6 Hinge (std weight) TA2714 US26D MK 2 Manual Flush Bolt 555 / 557 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Storeroom Lock R AU 5405LN 626 YA 1 Removable Core 8027 626 RU 2 Surf Overhead Stop 10-X36 689 RF 2 Silencer 608-RKW RO Notes: Coordinate new hardware requirements with existing conditions. Doors: 100A, 100C, 101A, 101C, 103A, A2A, A6-A Set: 2.0 3 Hinge (std weight) TA2714 US26D MK 1 Storeroom Lock R AU 5405LN 626 YA 1 Removable Core 8027 626 RU 1 Door Stop 403 / 441H to suit condition US26D RO DOOR HARDWARE 087100-1

LOUIS H FARRELL ES PHILADELPHIA, PA 3 Silencer 608-RKW RO Notes: Coordinate new hardware requirements with existing conditions. Doors: 100, 101, 103, A2, A6 Set: 3.0 3 Hinge (half surface) TA2772 US26D MK 1 Classroom Intruder Lock R AU 5418LN 626 YA 2 Removable Core 8027 626 RU 1 Surface Closer PR7500 689 NO 1 Kick Plate K1050 10" BEV CSK US32D RO 1 Door Stop 403 / 441H to suit condition US26D RO 3 Silencer 608-RKW RO Notes: Coordinate new hardware requirements with existing conditions. Doors: 100B, 101B Set: 4.0 3 Hinge (std weight) TA2714 US26D MK 1 Privacy Set AU 5402LN 626 YA 2 Kick Plate K1050 10" BEV CSK US32D RO 1 Door Stop 403 / 441H to suit condition US26D RO 3 Silencer 608-RKW RO Notes: Coordinate new hardware requirements with existing conditions. END OF SECTION 087100 DOOR HARDWARE 087100-2

Metal Box Speakers Models MB8TSQ, MB8TSL, MB8TSQVR, and MB8TSLVR MB8TSQ(VR) recessed volume control, VR models MB8TSL(VR) Description Bogen's MB8TSQ and MB8TSL speakers feature an all-steel surface-mounted enclosure with an 8" cone loudspeaker and multi-tap 4-watt 70V/25V transformer. The MB8TSQ speakers are suitable for ceiling or wall mounting. The MB8TSL speakers are designed primarily for wall mounting, with front face angled downward by 12.5 degrees. Models with VR suffix have a recessed volume control at the center of the grille (see inset). Features Rugged all-steel surface-mounted enclosure Full range 8" cone speaker for excellent intelligibility Compatible with 25V or 70V amplifier systems Multiple taps at 4, 2, 1, 1/2, 1/4, 1/8 watts 4-Watt maximum output power Mounting hardware included (toggle bolts, wood screws and wire crimps) Knockouts for Wiremold VR Models feature recessed volume control at the center of front speaker grille Technical Specifications Cone Diameter: Magnet Weight: Power Rating (max.): Transformer Power Taps: Constant Voltage Amp Type: Frequency Response: Sensitivity (min.): 8" (paper) 6 oz. 4 Watts Dispersion (min.): 100 Product Weight: 4, 2, 1, 1/2, 1/4, 1/8 Watts 70V or 25V 110 Hz -15 khz 96 dbspl (1W @ 1m on axis) 9 lb. Enclosure Size: MB8TSQ(VR) - 11-5/8" W X 11-5/8" H X 4-1/4" D; MB8TSL(VR) - Top: 11-5/8" W X 11-5/8" H X 5-3/8"; - Bottom: 11-5/8" W X 11-5/8" H X 3-1/8" D Construction: Painted steel enclosure Architect & Engineer Specifications The speaker shall be a Bogen Model (specify MB8TSQ, MB8TSQVR, MB8TSL, or MB8TSLVR). The unit shall include an 8" paper cone speaker with 6 oz. magnet. The frequency response shall be 110 Hz to 15 khz. Dispersion angle shall be no less than 100. Sensitivity, measured 1 watt @ 1 meter on axis, shall be a minimum of 96 dbspl. The unit shall incorporate a transformer with tap selection wires corresponding to power settings of 4, 2, 1, 1/2, 1/4, and 1/8 watts for both 70V and 25V constant voltage speaker systems. Models with VR suffix shall feature a recessed volume control centered in the front speaker grille. The speaker enclosure shall be full steel construction and allow for surface mounting. The enclosure shall be painted off-white and measure [specify 11-5/8" W X 11-5/8" H X 4-1/4" D for MB8TSQ(VR) or 11-5/8" W X 11-5/8" H X 5-3/8" D (top) and 11-5/8" W X 11-5/8" H X 3-1/8" D (bottom) for MB8TSL(VR)]. The speaker enclosure shall also provide Wiremold knockouts. Front face of models MB8TSL(VR) shall be angled by 12.5 degrees downward. Product weight shall be 9 lb. Specifications subject to change without notice. 2005 Bogen Communications, Inc., Part No. 54-8023-30D 0809 Wiremold is a registered trademark of Wiremold/Legrand 50 Spring Street, Ramsey, NJ 07446, U.S.A. 201-934-8500 FAX: 201-934-9832 www.bogen.com