General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup

SHIMADEN DIGITAL INDICATORS

General Specifications

Model UP350 Program Controller

General Specifications

General Specifications

SHIMADEN DIGITAL INDICATORS

General Specifications

SHIMADEN DIGITAL INDICATOR

Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control

Models UT350/UT320 Digital Indicating Controllers

SHIMADEN PROGRAM CONTROLLER

General Specifications

General Specifications

Model UP750 Program Controller User s Manual for Dual-loop Control

Model UT551 Digital Indicating Controller with Active Color PV Display and Embedded Ethernet User s Manual for Single-loop Control

Model UP351 Program Controller

General Specifications

DIGITAL PROGRAM CONTROLLER

General Specifications

Model UT750 Digital Indicating Controller User s Manual for Cascade Control

DIGITAL INDICATING CONTROLLER

DC1010/DC1020/DC1030/DC1040

Model UT750 Digital Indicating Controller User s Manual for Cascade Primary-loop Control

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: R30US4. Remote I/O R30 Series

General Specifications

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

Model UP550 Program Controller User s Manual for Cascade Primary-loop Control

CompoBus/D-type Digital Controller

General Specifications

MICRO-CONTROLLER X (48 48 mm)

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Model UP550 Program Controller User s Manual for Loop Control with PV Switching

General Specifications

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

Process displays For standard signals, temperature, resistance measurement

SHIMADEN DIGITAL CONTROLLER

Temperature Controllers E5 J

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224

General Specifications

General Specifications


General Specifications

Model Number Structure

General Specifications

Digital indicator for panel mounting With multi-function input Model DI25

MODEL: M1EXT. with Display M1E Series

General Specifications

MICRO-CONTROLLER X (96 96 mm)

PROGRAM CONTROLLER OUTLINE

VIEW RECORDERS SPECIFICATIONS

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

General Specifications

APPENDIX APPENDIX A 1

MODEL: TC10EM. Temperature Controller TC10 Series

General Specifications

µr SERIES RECORDERS VIEW RECORDERS 4365 & 4375 Recorders FUNCTIONS FEATURES

High Performance Process & Temperature Controllers

General Specifications

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: W2TS. Mini-MW Series

General Specifications

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

Analogue temperature controllers

General Specifications

General Specifications

HYBRID RECORDER OUTLINE

Excellent low-cost Process & Temperature Controllers

PROGRAMMABLE CONTROLLER

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

SDC40A. DigitroniK TM Digital Indicating Controller RSW. Control unit PID (8) Auto tuning+ Neuro & Fuzzy RUN/READY R/L LSP.

DCP552B Mark II. DIGITRONIK TM Programmable Controller. Control operation block. Mode transition. PID control Auto-tuning.

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

MICRO-CONTROLLER X (48 96 mm)

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

PROCESS & TEMPERATURE CONTROLLERS

General Specifications

Hawk 3 Digital Panel Meter / Controller

DigitroniK TM Digital Indicating Controller SDC20

Fuzzy Temperature Controllers E5AF

DCP551B Mark II. DIGITRONIK TM Programmable Controller. Control operation block. Mode transition. PID control Auto-tuning.

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

SRX. General Description. Features. Module type High-speed Digital Controller SRX. Multi-Zone Space-Saving. High-speed Feedback Control

SHIMADEN PROGRAMMABLE CONTROLLER

Transcription:

General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user. The UT50L features universal input, two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. TheRS85 communication interface is available optionally. UT50L Features The large LED display of process variable whose character is 0mm in height allows the good readability. Universal input is provided. The input type can be set and changed easily by software. Retransmission function is included in the standard features. setpoint Function Specifications Limit control Function Setpoint : Control type : high limit or low limit Limit action : latching EXCEEDED Lamp light process value When process variable(pv) exceeds the setpoint(sp), both the Exceeded lamp and OUT lamp turn on.() Exceeded lamp turns off when PV goes into normal status, however, OUT lamp remains lit.() OUT lamp turns off when the confirmation is done with pressing the RESEST key by the operator.() The confirmation(reset) is not allowed while PV exceeds SP.() State of Output relay State of output relay is di-energized whenever OUT lamp is lit. When PV has not exceeded SP since power-on, state of output relay is di-energized.(nc terminal : CLOSE, NO terminal : OPEN) and after confirmation is done, the state of output relay is energized.(nc terminal : OPEN, NO terminal : CLOSE) It is also possible to make the relay energized immediately after power-on by the software setting. At power-off, the relay is di-energized(nc : terminal : CLOSE, NO terminal : OPEN). OUT Lamp light process value setpoint EXCEEDED Lamp light OUT Lamp light confirmation confirmation confirmation (No accepted) Control parameter setting range: ON/OFF hysteresis band : 0.0 to 00.0 of instrument range width. Resrart Mode: Relay status at power-on can be selected. confirmation confirmation (No accepted) power off power on & confirmation not over temp (Settable as off, either) GS 5DD-0E Copyright Apr. 99 (YK) st Edition Jul. 99 (YG)

Signal Computation Function Measured input computation: Bias addition (-00.0 to 00.0% of measured input range width), and first-order lag filter (time constant off or to 0s) Contact input function: Limit output confirmation Alarm Function Types of alarm functions are provided. The alarm status is indicated by the alarm lamp on the front panel. Also, two points among them can be output as relay contact outputs. Alarm types: PV high limit, PV low limit, Deviation high limit, Deviation low limit, Deenergized on deviation high limit, Deenergized on deviation low limit, Deviation high and low limits, High and low limits within deviation, Deenergized on PV high limit, Deenergized on PV low limit. Alarm output: points. Setting ranges for PV, deviation, setpoint and output alarms: PV alarm: -00.0 to 00.0% of measured input range Deviation alarm: -00.0 to 00.0% of measured input range width Alarm hysteresis width: 0.0 to 00.0% of measured input range width Waiting action Waiting action can be set to make PV/deviation alarm stand-by during start-up or after SP change until SP reaches the normal region. Fault diagnostic alarm: Input burnout, A/D conversion error, thermocouple reference junction compensation error FAIL output: Software failure and/or hardware failure When in fail, control output, retransmission output and alarm output become 0% or OFF. Display and Operation Function PV display: In -digit digital display of engineering unit Setpoint display: Various data, such as the setpoint (SP), are displayed by selection on the -digit digital display. Status indicating lamps: alarm indicator lamps :AL, AL Exceeded lamp :Lit when PV exceeds SP Output status lamp :Lit when output relay is di-energized. Operation keys: and keys: Increases or decreases setpoints and various parameters. SET/ENT key: For data setting or call-up/selection of various parameters. RESET key: Confirm the limit status and reset. Security function: An operation-inhibiting mode using a password is provided. All Rights Reserved. Copyright 99, Yokogawa M&C Corporation Communication Specificattions (optional) This controller has a communication function and can be connected to a personal computer, programmable controllers or other GREEN series controllers. Communication protocol Computer link communication: Communication protocol with a personal computer. Ladder communication: Communication protocol with programmable controller. Communication interface Communication protocol: Computer link or ladder communication Standards: EIA RS85 Maximum number of connectable controllers: GREEN series controllers Maximum communication distance :,00 m Communication method: Two-wire half duplex or four-wire half duplex, start-stop synchronization, nonprocedural. Communication rate: 00, 00, 00, 800, 900 bps Hardware Specifications Measured Input Signal Number of input points : Input system: The types of input/measurement ranges can be set using software from a list of inputs. Types of inputs, measurement ranges and measurement accuracy: Refer to the table on page. Burnout detection: Functions with a thermocouple (TC), RTD, standard signal 0. to V, and to 5 V. Can be specified as upscale, downscale, and off. For standard signal, judged as burnout at 0. V or less. Input bias current : 0.05 µa (for TC/RTD) Input resistance: MΩ or more for TC/mV About MΩ for DC voltage input Allowable signal source resistance: 50 Ω or less; effect of permissible signal source resistance 0. µv/ω or less for TC/mV k Ω or less; effect of permissible signal source resistance 0.0%/00 Ω or less for DC voltage Allowable leadwire resistance: Max. of 50 Ω/wire (resistance in each of three wires must be equal) for RTD However, 0 Ω/wire in the range of -50.0 to 50.0 C. Effect of permissibe leadwire resistance 0. C/0 Ω or less Allowable input voltage: ± 0 V DC for TC/mV/RTD ± 0 V DC for DC voltage Noise rejection ratio: Normal mode 0 db (50/0 Hz) or more Common mode0 db (50/0 Hz) or more GS 5DD-0E st Edition Jul.0, 99-00

Reference-junction compensation error: ±.0 C (5 to 5 C), ±.5 C (0 to 5 C, 5 to 50 C) Applicable standards : JIS, IEC, or DIN for TC and RTD Retransmission Output Either PV or target setpoint is output. Number of output points: Output signal : to 0 ma DC Load resistance : 00 Ω or less Output accuracy : ± 0.% of span Control Output The control output is a relay output. Relay contact output Number of output points : Output signal: Three terminals for NC, NO, and Common transfer-contacts Contact rating: 50 V AC, A or 0 V DC, A (resistive load) Resolution : 0 ms Contact Input Usage: confirmation of limit output Number of input points : Input type : Voltage-free contact input or transistor contact input Input contact rating : V DC, 0 ma or more On/off determination : For contact input, ON = contact resistance of kω or less, OFF = contact resistance of 0 kω or more. For transistor contact input, ON = V or less, OFF = leakage current of 00 µa or less. Minimum retention time for status detection : 0.s Contact Output Usage : Alarm output and FAIL output Number of relay contact output points : Relay contact rating: 0 V AC, A or 0 V DC, A; Display Specifications PV display: -digit, -segment red LED; character height - 0 mm Setpoint display: -digit, -segment red LED; character height - 9. mm Status indicating lamps : LEDs Conformance to Safety and EMC Standards Safety: Conforms to IEC00- : 990 and EN00- : 99. Certified for FM-80 and FM-55. The overvoltage category of each input is CAT (IEC00-) Certified for UL508. EMC standards: Conforms to the following standards. EN550 : Class A Group for EMI (emissions) EN5008- : 995 for EMS (immunity) Construction, Mounting, and Wiring Construction:Front panel drip-proof (IP55 compatible) Material :ABS resin and polycarbonate Case color :Black Weight :Approx. kg. or less External dimensions: 9 (width) 9 (height) 00 (depth) mm Mounting :Direct panel mounting; mounting bracket, one each for upper and lower mounting Panel cutout dimensions : 9 +0.8 0 (width) 9 +0.8 0 (height) mm Mounting attitude: Up to 0 degrees above the horizontal. No downward tilting allowed. Wiring: M.5 (ISO.5 mm) screw terminals (signal wiring and power/ground wiring as well) Status lamps Alarm(AL, ), EXCEEDED, OUT Operational keys Increase/Decrease the setting data (, ) Select parameter/enter the setting data (SET/ENT) Confim and reset the output(reset) LED display unit (for PV) Display PV, and error code when error is detected. LED display unit (for SP) Display setpoint (SP) and setting item/value of parameters. All Rights Reserved. Copyright 99, Yokogawa M&C Corporation GS 5DD-0E st Edition Jul.0, 99-00

Power Supply Specifications and Isolation Power supply : Rated at 00 to 0 V AC (±0%), 50/0 Hz Power consumption : MAX. 0 VA (MAX. 8.0 W) Memory back-up: Non-volatile memory. Withstanding voltage: 00 V AC for minute between primary and secondary terminals. 00 V AC for minute between primary and ground terminals. 500 V AC for minute between ground and secondary terminals. 500VAC for minute between two secondary terminals. Primary terminals = power and relay output terminals Secondary terminals = Analog I/O signal terminals, voltage pulse output terminals, contact input terminals. Insulation resistance: 0 MΩ or more when 500 V DC voltage is applied between the power terminals and ground terminal. Grounding: Class grounding (grounding resistance of 00 Ω or less) Isolation specifications Measured input terminal: Isolated from other I/O terminals. Not isolated from internal circuits. Analog to 0 ma output (retransmission) terminal: Not isolated from another to 0 ma output terminals each other, loop power supply terminals, and voltage pulse control output terminal. Isolated from other I/O terminals and internal circuits. Relay contact control output terminals: Isolated from other contact output terminals, other I/ O terminals and internal circuits. Contact input terminals: Not isolated from other contact input terminals, and communication terminals. Isolated from other I/O terminals and internal circuits. Relay contact output terminals: Not isolated from other relay contact output terminals. Isolated from other I/O terminals and internal circuits. RS-85 communication terminals: Not isolated from contact input terminals. Isolated from other I/O terminals and internal circuits. Power supply terminals: Isolated from other I/O terminals, ground terminal, and internal circuits. Ground terminal: Isolated from other I/O terminals, power terminals, and internal circuits. Input Type Input range code Instrument range ( C) Instrument range ( F) Measurement accuracy Thermocouple K J -00 to 0 C -99.9 to 999.9 C -99.9 to 500.0 C -99.9 to 999.9 C -00 to 500 F 0 to 00 F -99.9 to 999.9 F -00 to 00 F At or above 0 C Below 0 C, ±0.% ± digit of F.S. T 5-99.9 to 00.0 C -00 to 50 F 0.0 to 00.0 C -99.9 to 50.0 F B S R N E L (DIN) 8 9 0 0 to 800 C 0 to 00 C 0 to 00 C -00 to 00 C -99.9 to 999.9 C -99.9 to 900.0 C to 00 F to 00 F to 00 F -00 to 00 F -00 to 800 F -00 to 00 F At or above 00 C ±0.5% ± digit of F.S. Below 00 C ±5% ± digit of F.S. ±0.5% ± digit of F.S. At or above 0 C Below 0 C ±0.% ± digit of F.S. U (DIN) -99.9 to 00.0 C -00 to 50 F 0.0 to 00.0 C -99.9 to 50.0 F W (DIN) Platinel 5 0 to 00 C 0 to 90 C to 00 F to 500 F ±0.% ± digit of F.S. PR0-0 0 to 900 C to 00 F At or above 800 C ±0.5% ± digit of F.S. Below 800 C, not guaranteed RTD Standard signal DC voltage W9Re-W5Re5 JPt00 Pt00 0. to V to 5V 0 to V 0 to 0V -0 to 0mV 0 to 00mV 8 0 5 0 50 5 55 5 0 to 000 C -99.9 to 500.0 C -50.0 to 50.0 C -99.9 to 0.0 C -99.9 to 500.0 C -50.0 to 50.0 C 0.00 to.000.000 to 5.000 0.000 to.000 0.00 to0.00-0.00 to 0.00 0.0 to 00.0 to 00 F -99.9 to 999.9 F -99.9 to 00.0 F -00 to 80 F -99.9 to 999.9 F -99.9 to 00.0 F Scaling is enable in the following range. -999 to 9999-99.9 to 999.9-9.99 to 99.99 -.999 to 9.999 ±0.% ± digit of F.S. ±0.% ± digit of F.S. ±0.% ± digit of F.S. All Rights Reserved. Copyright 99, Yokogawa M&C Corporation GS 5DD-0E st Edition Jul.0, 99-00

5 Environmental Conditions Normal operating conditions: Ambient temperature: 0 to 50 C (0 C or less for mounting of instruments side-by-side Temperature fluctuation:max. 0 C/h) Ambient humidity :0 to 90% RH (no condensing) Magnetic field :00 AT/m or less Continuous vibration (5 to Hz): Peak-to-peak amplitude of. mm or less Continuous vibration ( to 50 Hz):.9 m/s (0.5G) or less Short-period vibration :. m/s (.5G), 5s or less Shock : m/s (5G) or less, ms Installation altitude :,000 m or less above sea level Attitude for installation:max. 0 off vertical. Do not install upside-down. Installation category based on IEC00: (See Note.) Pollution level based on IEC00: (See Note.) Note: The Installation category implies the regulation for impulse withstand voltage. It is also called the Overvoltage category. applies to electrical equipment. Pollution level describes the degree to which a solid. liquid or gas which deteriorates dielectric strength is adhering applies to a normal indoor atmosphere. Transportation and storage conditions: Temperature :-5 to 0 C Humidity :5 to 95% RH Effects of operating conditions Effect of ambient temperature: For voltage or TC inputs: Whichever is greater, ± µv / C or ±0.0% of F.S./ C For RTD inputs: ±0.05 C/ C or less for RTD input For analog output : ±0.05% of F.S. / C or less Effect of power supply fluctuation (within rated voltage range): For analog input: Equal to or less than whichever is greater, ± µv/ 0 V or ± 0.0% of F.S./0 V For analog output : ±0.05% of F.S./ 0 V or less All Rights Reserved. Copyright 99, Yokogawa M&C Corporation GS 5DD-0E st Edition Jul.0, 99-00

Terminal Numbers Terminal diagram Terminal number 5 8 9 0 5 8 9 0 5 8 9 0 Symbol OUTPUT ALM SUPPLY INPUT RET DI RS85 (*) (*) Available when model code is UT50L-0. Signal Description Control output (relay contact) NC Control output (relay contact) NO Control output (relay contact) COM Alarm contact output, relay output Alarm contact output, relay output Alarm contact output, Common(output terminals 5 and ) Power supply L Power supply N Ground Measured input terminal A(RTD) Measured input terminal +(TC, mv, V) b(rtd) Measured input terminal -(TC, mv, V) B(RTD) Retransmission output + Retransmission output - External contact input External contact input common (input terminals 9) RS85 communication SDB(+) RS85 communication SDA(-) RS85 communication RDB(+) RS85 communication RDA(-) RS85 communication SG 5 8 9 0 5 5 8 8 9 9 0 0 All Rights Reserved. Copyright 99, Yokogawa M&C Corporation GS 5DD-0E st Edition Jul.0, 99-00

External Dimensions.General mounting.close mounting side-by-side Unit :mm [(N-) 9 9] 0.8 0 minimum 0.8 0 9 N shows the number of mounted instruments, However, if N 5, this dimension depends on the actual measurement. 5 minimum (5) 9 + 0 0.8 (5) 9 + 0 0.8-05-0-50-0-0-0 9.8 maximum 9 00 PV SP EXCEEDED AL out UT50L 9 9.8 maximum maximum RESET SET/ENT (Panel thickness) to 0 Model Specification Model Suffix code Description UT50L Limit controller(with Retransmission output) -0 General-purpose controller 0 None Optional functions With communication Standard Accessories Instruction manual, mounting bracket Items to be specified when ordering Model and suffix codes All Rights Reserved. Copyright 99, Yokogawa M&C Corporation GS 5DD-0E st Edition Jul.0, 99-00