Models UT350/UT320 Digital Indicating Controllers

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup

Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control

General Specifications

General Specifications

How to Install CAUTION. Panel. 150mm. 150mm. Direction to insert the controller Insert the controller into the opening at the front of the panel.

Model UP350 Program Controller

Model UT750 Digital Indicating Controller User s Manual for Cascade Control

Model UT551 Digital Indicating Controller with Active Color PV Display and Embedded Ethernet User s Manual for Single-loop Control

General Specifications

General Specifications

Model UP550 Program Controller User s Manual for Loop Control with PV Switching

General Specifications

Model UP351 Program Controller

General Specifications

Model UP750 Program Controller User s Manual for Dual-loop Control

General Specifications

Temperature Controllers E5 J

General Specifications

DIGITAL PROGRAM CONTROLLER

General Specifications

Model UT750 Digital Indicating Controller User s Manual for Cascade Primary-loop Control

indicate that the contacts are available. How to Install CAUTION Panel

High Performance Process & Temperature Controllers

DIGITAL INDICATING CONTROLLER

Model UP550 Program Controller User s Manual for Cascade Primary-loop Control

SHIMADEN PROGRAM CONTROLLER

General Specifications

MICRO-CONTROLLER X (48 48 mm)


General Specifications

General Specifications

Excellent low-cost Process & Temperature Controllers

SHIMADEN DIGITAL INDICATORS

PROCESS & TEMPERATURE CONTROLLERS

APPENDIX APPENDIX A 1

Fuzzy Temperature Controllers E5AF

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

General Specifications

General Specifications

CompoBus/D-type Digital Controller

MICRO-CONTROLLER X (96 96 mm)

User s Manual. Model US1000 Digital Indicating Controller Functions. IM 5D1A01-02E 2nd Edition IM 5D1A01-02E

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

SDC40A. DigitroniK TM Digital Indicating Controller RSW. Control unit PID (8) Auto tuning+ Neuro & Fuzzy RUN/READY R/L LSP.

PROGRAM CONTROLLER OUTLINE

General Specifications

UT750. Relay. 150mm. UT s contact. Relay (Use one with a relay coil rating less than the UT s contact rating.) 150mm. Recommended Terminal Lugs

General Specifications

MICRO-CONTROLLER X (48 96 mm)

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224

Single Loop Controller SDC35/36

SHIMADEN DIGITAL CONTROLLER

DigitroniK TM Digital Indicating Controller SDC20

SHIMADEN DIGITAL INDICATOR

DC1010/DC1020/DC1030/DC1040

Fuzzy Temperature Controllers E5EF

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

PROGRAMMABLE CONTROLLER

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

MODEL: R30US4. Remote I/O R30 Series

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER

UP550 O.C. Relay. UP s contact. 150mm. Relay. (Use one with a relay coil rating less than the UP s contact rating.) 150mm. Recommended Terminal Lugs

General Specifications

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

Analogue temperature controllers

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

SHIMADEN DIGITAL INDICATORS

Process and Temperature Controllers

Multi-point Temperature Controller

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

Network Instrumentation Module Controller Module NX-D15/25/35

Process Controller. PX series INSTRUCTION MANUAL. Thank you for the purchase of HANYOUNG product. Please read this manual carefully.

Model Number Structure

General Specifications

Temperature Controller

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

General Specifications

DCP552B Mark II. DIGITRONIK TM Programmable Controller. Control operation block. Mode transition. PID control Auto-tuning.

Process displays For standard signals, temperature, resistance measurement

7SD/7SH/7SM Temperature Controllers

VIEW RECORDERS SPECIFICATIONS

DCP551B Mark II. DIGITRONIK TM Programmable Controller. Control operation block. Mode transition. PID control Auto-tuning.

General Specifications

Transcription:

General Specifications Model UT30 Digital Indicating Controller GS 05D0D00E General Model UT30 Digital Indicating Controller is a highly accurate /8 DIN controller, provided with universal input/ output. It has a large display for readings and excellent monitoring operability with the Auto/Man switching key. In addition, heating/cooling control, including PID control with autotuning, the overshoot suppressing function SUPER and the hunting suppressing function SUPER are available as control functions, and a retransmission of variables or a 5V DC loop power supply are also equipped as standard. A communication function or V DC loop power supply is available optionally. As described above, the UT30 is a controller provided with higher functions and capability than conventional similarsize controllers. UT30 UT30E E indicates the model with expanded functions. Main Features The latest in large digital displays has been realized and a large display with characters mm in height has been employed to be clearly readable from distant locations. Universal input and output enable users to set or change freely the type of measured inputs (thermocouple, RTD or DCV), measurement range, type of control output ( to 0 ma current, voltage pulse, or relay contact), etc. from the front panel. Parameters can be easily set using a personal computer. ("Parameter setting tool (model LL00)" sold separately is required.) Various communication function are provided. Communication is possible with personal computer, programable logic controller, and other controllers. Reference point = Measuring input range (0%) Reference point Reference point Measuring input range (00%) Reference point hysteresis = Fixed to 0.5% of the measured input range width. Reference deviation method: PID parameters (No. PID) are selected when the deviation exceeds the reference deviation. This process takes precedence over the reference point method. Reference deviation = OFF or 0. to 00.0% of measured input range width Measuring input range (00%) Reference deviation No.3PID Function Specifications Reference point Reference deviation Control Computation Functions Control computation: Can be selected from the following types: Continuous PID control, Timeproportional PID control, Heating/Cooling control (for heating/ cooling type only) or Relay ON/OFF control. Control cycle time: 50 ms Number of sets of target setpoints and PID parameters: Target setpoint and PID selection: PID parameters are provided for every target setpoint and the set of PID parameters are selected at the same time that the setpoint number is selected. Zone PID selection: PID parameters are selected depending on the value of the. For selection, the reference point (PID parameter selection setpoint) or the reference deviation is used. Reference point method: The measuring input range is divided into a maximum of three zones with up to two reference points, and PID parameters are selected (No. PID to No. 3 PID) for every zone. Reference point Measuring input range (0%) Measured value () No.PID No.PID Autotuning: Available as standard. If autotuning is operated, PID parameters are automatically set (limit cycle method). SUPER function: Overshoots generated by abrupt changes in the target setpoint or by disturbances can be suppressed. SUPER function: The function stabilizes the state of control that is unstable due to hunting, etc. without requiring any change in PID constants, when the load and/or gain varies greatly, or when there is a difference between the characteristics of temperature zones. GS 05D0D00E Copyright Feb. 000 3rd Edition Jul. 00

Control Parameters Setting Range Proportional band = 0. to 999.9% 0.0 to 999.9% (for heating/cooling control, 0.0% for ON/OFF control) Integral time = to 6,000 s, or OFF (manual reset) Derivative time = to 6,000 s, or OFF Manual reset value = 5.0 to 05.0% of output range (functions when integral time is off.) ON/OFF control hysteresis = 0.0 to 00.0% of measured input range width (0. to 0.5% for heating/ cooling control) Setpoint rateofchange setting = off, or 0.0 to 00.0%/h or min. of measured input range width A tracking function operates automatically when the setpoint is changed, the power is turned on, or the mode is changed from manual to automatic. Direct/reverse action: The output increase/decrease direction can be defined corresponding to a positive or negative deviation. For heating/cooling control, it is fixed; for the heating side output, reverse, for the cooling side output, direct. Antireset windup: When controller output is limited, normal integration is superseded by an antireset windup computation to suppress overintegration. Control output cycle time = to 000 s (for Timeproportional PID control) and (the cooling side output cycle time is also the same when heating/cooling control is used). Preset output value = 5.0 to 05.0% of output range Output tracking: Whether the output bump is provided or not can be selected by changing the PID control mode. Output limiter Upper limit = Lower limit to 05.0% of output range Lower limit = 5.0% of output range to upper limit Heating/cooling dead band = 00.0 to 50.0% for output range Signal Computation Functions Measured input computation: Bias addition (00.0 to 00.0% of measured input range width), and firstorder lag filter (time constant off or to 0 s) Contact input function: Target setpoint selection, Auto/Man operating mode switching, key lock parameter display/ nondisplay switching Target setpoint selection can be done for either a setpoint or setpoint selection. If the setpoint selection is set, Auto/Man mode switching can be used as well. If the setpoint selection is set, Auto/Man switching and key lock parameter display/nondisplay switching cannot be used together. If key lock parameter display/nondisplay switching is used, target setpoint selection and Auto/Man mode switching cannot be used. Alarm Functions Eighteen types of alarm functions are provided. The alarm status is indicated by the alarm lamp on the front panel. Also, three points among them can be output as relay contact outputs. All Rights Reserved. Copyright 000, Yokogawa Electric Corporation Alarm types: high limit, low limit, Deviation high limit, Deviation low limit, Deenergized on deviation high limit, Deenergized deviation low limit, Deviation high and low limits, High and low limits within deviation, Deenergized on high limit, Deenergized on low limit, SP high limit, SP low limit, Output high limit, Output low limit,heater disconnection alarm, Sensor prounding alarm,fail output. Alarm output: 3 points. Any three points can be output as contact outputs among the above alarm. For heating/cooling control, if cooling side output is output as a relay contact, up to two alarm outputs can be used. Setting ranges for, deviation, setpoint and output alarms: /setpoint alarm: 00.0 to 00.0% of measured input range Deviation alarm: 00.0 to 00.0% of measured input range width Output alarm: 5.0 to 05.0% of output range Alarm hysteresis width: 0.0 to 00.0% of measured input range width Delay timer: 0.00 to 99.59 (minute, second) An alarm is output when the delay timer expires after the alarm setpoint is reached. Setting for each alarm is possible. Standby action: Standby action can be set to make / deviation alarm OFF during startup or after SP change until SP reaches the normal region. Heater disconnection alarm (optional): two circuits incorporated A heater disconnection alarm is output if the heater current consumption is the disconnection detection value or less. This alarm can be used for Relay ON/OFF control or timeproportional PID control. Heater current setting range: 0.0 to 50.0 A Setting accuracy: ±5% of span ± digit Heater current detecting resolution: 0.5 A Time required until disconnection detection is on: 0. s minimum Disconnected sensor model: CTL6SH (URD Co. Ltd.) Sensor grounding alarm: An alarm is output after detecting a change in control output. If the moving average * of control output is out of the setting range (between the high and low limits of the on/off rate) in spite of the deviation being within a fixed range (on/off rate detection width) and control being in stable condition, the sensor is judged to be in a grounding condition. * Moving average refers to the average value for output values sampled (five times) in every cycle time. High and lowlimit setting range of on/off rate: 5.0 to 05.0% of output range Detection width of on/off rate: 0.0 to 00.0% of measured input range width. Fault diagnostic alarm: Input burnout, A/D conversion error, thermocouple reference junction compensation error FAIL output: Software failure and/or hardware failure When in Fail, control output, retransmission output and alarm output become 0% or off. GS 05D0D00E 3rd Edition Jul. 30, 0000

3 Display and Operation Function display: In digit digital display for engineering data Setpoint display: Various data, such as the setpoint (SP), are displayed by selection on the digit digital display. Status indicating lamps: 3 alarm indicator lamps:,, 3 3 setpoint number indicator lamps: SP, SP3, SP (Go out when SP is selected.) MAN operation mode lamp: MAN (lit in MAN mode) Operation keys: and keys: Increases or decreases setpoints and various parameters. key: For data setting or callup/selection of various parameters key: Switching of operation mode (Auto/Man) SELECT display: A panel where operating parameters that are frequently changed during operation can be selected and registered. For example, by registering the alarm setpoint in the SELECT display, the setpoint can easily be displayed during operation. Security function: An operationinhibiting mode using a password is provided. Status lamps Alarm (,, 3), Manual (MAN). Setpoint No (SP, 3, ). in use. Communication port for light loader Parameters are set via communication from a personal computer. Operational keys Increase/Decrease the setting data (, ) Select parameter/enter the setting data () mode switching () LED display unit (for ) Display, and error code when error is detected. LED display unit (for SP) Display setpoint (SP), output value, and setting item/value of parameters. All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition Jul. 30, 0000

MAN MAN MAN MAN MAN MAN MAN MAN MAN 3 MAN 3 MAN 3 MAN 3 MAN <<Contents>> <<Index>> Communication Functions (optional) This controller has a communication function and can be connected to a personal computer, programmable logic controller, or other /GREEN series controllers. Communication protocol Computer link communication: Communication protocol with a personal computer. Ladder communication: Communication protocol with programmable logic controller made. MODBUS communication: Communication protocol with a personal computer or PCL. Coordinated operation: Communication protocol to coordinate operation with two or more GREEN series controllers. The UT30 can be connected as a master station or a slave station. Communication interface Communication protocol: Computer link, ladder communication, MODBUS communication or coordinated operation Standards: EIA RS85 Maximum number of connectable controllers: 3 GREEN series controllers Maximum communication distance:,00 m Communication method: Twowire half duplex or fourwire half duplex, startstop synchronization, nonprocedural Communication rate: 600, 00, 00, 800, 9600 bps Examples of Communication System Configuration Diagram () Computer link communication/modbus communication () Ladder communication Personal computer MELSECA PLC UT350/UT30 Digital indicating controller (3) Coordinated operation UT350/UT30 Digital indicating controller UP350 Program controller or UT350/UT30 Digital indicating controller UT350/UT30 Digital indicating controller All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition Jul. 30, 0000

5 Hardware Specifications Measured Input Signal Number of input points: Input system: The types of input/measurement ranges can be set using Key operation or software from a list of inputs. Input type, measurement ranges and measurement accuracy: Refer to the table below. Input Type Input range code Instrument range ( C) Instrument range ( F) Measurement accuracy * Unspecified(when shipped from the factry) OFF Set the data item input Type"IN" to the OFF option to leave the input type undefined. Thermocouple RTD Standard signal DC voltage K J T B S R N E L (DIN) U (DIN) W (DIN) Platinel PR00 W97Re3W75Re5 JPt00 Pt00 0. to V to 5V 0 to V 0 to 0V 0 to 0mV 0 to 00mV 3 5 6 7 8 9 0 3 5 6 7 8 30 3 35 36 37 0 50 5 55 56 00 to 370 C 99.9 to 999.9 C 99.9 to 500.0 C 99.9 to 999.9 C 99.9 to 00.0 C 0.0 to 00.0 C 0 to 800 C 0 to 700 C 0 to 700 C 00 to 300 C 99.9 to 999.9 C 99.9 to 900.0 C 99.9 to 00.0 C 0.0 to 00.0 C 0 to 00 C 0 to 390 C 0 to 900 C 0 to 000 C 99.9 to 500.0 C 300 to 500 F 0 to 00 F 99.9 to 999.9 F 300 to 00 F 300 to 750 F 99.9 to 750.0 F 3 to 3300 F 3 to 300 F 3 to 300 F 300 to 00 F 300 to 800 F 300 to 300 F 300 to 750 F 99.9 to 750.0 F 3 to 00 F 3 to 500 F 3 to 300 F 3 to 3600 F 99.9 to 999.9 F 50.0 to 50.0 C 99.9 to 850.0 C 99.9 to 500.0 C 50.0 to 50.0 C 99.9 to 300.0 F 300 to 560 F 99.9 to 999.9 F 99.9 to 300.0 F 0.00 to.000 Scaling is enable in the following.000 to 5.000 range. 0.000 to.000 999 to 9999 0.00 to0.00 99.9 to 999.9 0.00 to 0.00 9.99 to 99.99 0.0 to 00.0.999 to 9.999 *: Performance in the standard operating conditon (at C ± C, 55±0%RH, and 50/60Hz power frequency) Note : The accuracy is ±0.3 C of instrument range ± digit for a temperature range from 0 to 00 C. Note : The accuracy is ±0.5 C of instrument range ± digit for an temperature range from 00 to 0 C and 00 to 00 C. ±0.% of instrument range ± digit for temperatures equal to or higher than 0 C, ±0.% of instrument range ± digit for temperatures below 0 C ±0.5% of instrument range ± digit for temperatures equal to or higher than 00 C ±5% of instrument range ± digit for temperatures below 00 C ±0.5% of instrument range ± digit ±0.% of instrument range ± digit ±0.5% of instrument range ± digit for temperature below 0 C ±0.% of instrument range ± digit for temperatures equal to or higher than 0 C ±0.% of instrument range ± digit for temperatures below 0 C ±0.% of instrument range ± digit ±0.% of instrument range ± digit ±0.5% of instrument range ± digit for temperatures equal to or higher than 800 C No guarantee of accuracy for temperatures below 800 C ±0.% of instrument range ± digit ±0.% of instrument range ± digit (Note ) (Note ) ±0.% of instrument range ± digit (Note ) ±0.% of instrument range ± digit (Note ) (Note ) ±0.% of instrument range ± digit (Note ) ±0.% of instrument range ± digit The readout range can be scaled between 999 and 9999. Sampling period: 50 ms Burnout detection: Functions with a thermocouple (TC), RTD, standard signal 0. to V DC, and to 5 V DC. Can be specified as upscale, downscale, and off. For standard signal, judged as burnout at 0. V or less. Input bias current: 0.05 µa (for TC/RTD bterminal) Measuring current(rtd): about 0.3mA Input resistance: MΩ or more for TC/mV input About MΩ for DC voltage input Allowable signal source resistance: 50 Ω or less; effect of permissible signal source resistance 0. µv/ω or less for TC/mV input kω or less; effect of permissible signal source resistance 0.0%/00 Ω or less for DC voltage input Allowable leadwire resistance: Max. of 50 Ω/wire (resistance in each of three wires must be equal) for RTD input However, 0 Ω/wire for a maximum range of 50.0 to 50.0 C. Effect of permmisible leadwire resistance ±0. C/0Ω or less All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition Jul. 30, 0000

Allowable input voltage: ±0 V DC for TC/mV/RTD input ±0 V DC for DC voltage input Noise rejection ratio: Normal mode 0 db (50/60 Hz) or more mode 0 db (50/60 Hz) or more Referencejunction compensation error: ±.0 C (5 to 35 C), ±.5 C (0 to 5 C, 35 to 50 C) Applicable standards: JIS, IEC, or DIN (ITS90) for TC and RTD V DC Loop Power Supply for Sensor The controller supplies power to a twowire transmitter. Place a resistor (0 to 50Ω)between the controller and the transmitter, convert a current signal to a voltage signal, and read it from the input..6 to 8.0V DC, maximum supply current is about 30mA (only for models with V DC loop power supply). Ambient temperature should be 0 to 0 C when using V DC loop power supply for UT30. V DC Power Supply Wiring to Twowire Sensor Twowire transmitter 0mADC External resistor (Note) input 50Ω to 5 V DC signal 3 Loop power supply.6 to 8.0 V DC Note: Connecting a 50 Ω resistor to the is optional. Model: X0050 (resistor with M3.5 crimpon terminal lugs) Retransmission Output Either, target setpoint, or control output is output. Either the retransmission output or the 5V DC loop power supply can be used. Number of output points: Output signal: to 0 ma DC Load resistance: 600 Ω or less Output accuracy: ±0.3% of span * Performance in the standard operating conditions (at ± C, 55± 0% RH, and 50/ 60 Hz power frequency) 5V DC loop power supply: Supply voltage is.5 to 8.0 V DC. Maximum supply current is about ma (with a protection circuit for a field shortcircuit). Control Outputs The control output is of a universal scheme and can be selected from the following types of outputs. In the case of heating/cooling control, it is also selectable from these outputs. However, if the cooling side output is a relay contact output, the alarm3 cannot be used, and similarly if the cooling side output is a voltage pulse or current output, the retransmission output/5v DC sensor power supply cannot be used. Current output Number of output points: or ( for heating/cooling), Swiched between voltage pulse output and current output. Output signal: to 0 ma Load resistance: 600 Ω or less Output accuracy: ±0.3% of span Performance in the standard operating conditions (at ± C, 55± 0% RH, and 50/60 Hz power frequency) Voltage pulse output Number of output points: or ( for heating/cooling type), Swiched between voltage pulse output and current output. Output signal: On voltage = V DC or more (load resistance of 600Ω or more; current on shortcircuiting about 30 ma) Off voltage = 0. V DC or less Resolution: 0 ms Relay contact output Number of output points: or ( for heating/cooling type) Output signal: Three for NC, NO, and transfercontact Contact rating: 50 V AC, 3 A or 30 V DC, 3 A (resistive load) Resolution: 0 ms Contact Inputs Usage: Target setpoint selection, Auto/Man mode switching, or Key lock parameter display/nondisplay switching Number of input points: Input type: Nonvoltage contact input or transistor open collector input Input contact rating: V DC, 0 ma or more (for nonvoltage contact input) On/off determination: For nonvoltage contact input, ON= contact resistance of kω or less, OFF= contact resistance of 0 kω or more. For transistor contact input, ON= V or less, OFF= leakage current of 00 µa or less. Minimum retention time for status detection: About second Contact Outputs Usage: Alarm output, FAIL output, and others Number of relay contact output points: 3 Relay contact rating: 0 V AC, A or 30 V DC, A ( is common for every contact output.) 6 Display Specifications display: digit, 7segment red LED; character height mm Setpoint display: digit, 7segment red LED; character height 9.3 mm Status indicating lamps: LEDS Conformance to Safety and EMC Standards Safety:Compliant with IEC/EN600: 00, approved by CSA00, approved by UL508. Installation category : CAT. II (IEC/EN600, CSA00) Pollution degree : (IEC/ EN600, CSA00) Measurement category : I (CAT. I : IEC/ EN600) Rated measurement input voltage : 0V DC max.(across ), 300V AC max.(across ground) Rated transient overvoltage : 500V (Note) All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition Jul. 30, 0000

Note : It is a value on the safety standard which is assumed by IEC/EN600 in measurement category I, and is not the value which guarantees an apparatus performance. EMC standards:complies with EN636 During test, the controller continues to operate with the measurement accuracy within ±0% of the range. Construction, Mounting, and Wiring Construction: Dustproof and Dripproof front panel conforming to IP55. For sidebyside close installation, controller loses its dustproof and dripproof protection. Material: ABS resin and polycarbonate Case color: Black Weight: Approx. kg or less External dimensions: 8 (width) 96 (height) 00 (depth) mm Mounting: Direct panel mounting; mounting bracket, one each for upper and lower mounting Panel cutout dimensions: 5 0.6 0 (width) 9 0.8 0 (height) mm Mounting attitude: Up to 30 degrees above the horizontal. No downward tilting allowed. Wiring: M3.5 (ISO 3.5 mm) screw (signal wiring and power/ground wiring as well) Power Supply Specifications and Isolation Power supply: Rated at 00 to 0 V AC (±0%), 50/60 Hz Power consumption: MAX. 0 VA (MAX. 8.0W) Internal fuse rating: 50 VAC, 6.A timelug fuse Memory backup: Nonvolatile memory (Service life approx. 000,000 times of writings) Withstanding voltage: 500 V AC for minute between primary and secondary 500 V AC for minute between primary and ground 500 V AC for minute between ground and secondary. 500V AC for minute between two secondary Primary = Power and relay output Secondary = Analog I/O signal, voltage pulse output, contact input Isolation resistance: 0 MΩ or more when 500 V DC voltage is applied between the power and ground terminal. Grounding: Class D grounding (grounding resistance of 00 Ω or less) Isolation specifications Measured input terminal: Isolated from other I/O. Not isolated from internal circuits. 5 V DC loop power supply : Not isolated from 0mA analog output and voltage pulse control output. Isolated from other I/O and internal circuit. V DC loop power supply : Isolated from other I/O and internal circuit. Control output (current or voltage pulse) and retransmission : Not isolated between control output and retransmission output terminal. Isolated from other I/O and internal circuits. Relay contact control output : Isolated from other I/O and internal circuits. Contact input : Not isolated from other contact input mutually, and communication. Isolated from other I/O and internal circuits. Relay contact alarm output : Isolated from other I/O and internal circuits. RS85 communication : Not isolated from contact input. Isolated from other I/O and internal circuits. Power : Isolated from other I/O, ground terminal, and internal circuits. Ground terminal: Isolated from other I/O, power, and internal circuits. 7 Environmental Conditions Normal operating conditions: Ambient temperature: 0 to 50 C (0 C or less for mounting of instruments sidebyside) The operating ambient temperature range is between 0 C and 0 C when the VDC loop power supply. Ambient temperature change limit:0 C/h or less Ambient humidity: 0 to 90% RH (no condensing) Magnetic field: 00 A/m or less Continuous vibration (5 to Hz): Peaktopeak amplitude of. mm or less Continuous vibration ( to 50 Hz):.9 m/s or less Shortperiod vibration:.7 m/s or less, 5 s Shock: 7 m/s or less, ms Installation altitude :,000 m or less above sea level Warmup time 30 minutes or more Transportation and storage conditions: Temperature: 5 to 70 C Temperature change limit:0 C/h or less Humidity: 5 to 95% RH Effect of operating conditions Effect of ambient temperature: For voltage or TC inputs: Whichever is greater, ± µv/ C or ±0.0% of F.S./ C For RTD inputs: ±0.05 C/ C (ambient temperature) or less for RTD input ±0.05% of F.S./ C For analog output: ±0.05% of F.S./ C or less Effect of power supply fluctuation (within rated voltage range): For analog input: Equal to or less than whichever is greater, ± µv/0 V or ± 0.0% of F.S./0 V For analog output: ±0.05% of F.S./0 V or less All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition Jul. 30, 0000

8 Function Block Diagram for Standard Type input, and 3 Communication to 7 Contact input INPUT RS85 DI DI Input selection Unit selection Input range conversion Input bias Input filter SP.NO Target setpoints to OTE LOC SP.NO=0 SP.NO= to Target setpoint ramprate function Manual operation Control computation MAN AUTO AUTO (ON)/MAN (OFF) switching Preset output Output limiter STOP RUN * V loop power supply OT 5 V loop power supply Retransmission output Alarm function Control output RET LPS Terminals and OUTPUT Current or pulse 6 and 7 OUTPUT Relay, and 3 OUTPUT /LPS Current and 5 DO DO DO3 Alarm Alarm Alarm 3 *: If the setup parameter DIS (DI function selection) is set to, when the contact input is ON (run state), that controller outputs the preset output value. Legend Terminal Parameter Function Analog signal Contact signal Front panel key All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition Jul. 30, 0000

9 Function Block Diagram for Heating/Cooling Type input, and 3 Communication to 7 Contact input INPUT RS85 DI DI Input selection Unit selection Input range conversion Input bias Input filter OTE SP.NO=0 SP.NO Target setpoints to LOC SP.NO= to Target setpoint ramprate function Manual operation Control computation MAN AUTO AUTO (ON)/MAN (OFF) switching Heating/cooling computation Heatingside output limiter Coolingside output limiter Heatingside preset output * * Coolingside preset output OT OT 5 V loop power supply Retransmission output Alarm function Heatingside output Coolingside output RET OUTPUT Current or pulse 6 and 7 OUTPUT Relay, and 3 OUTPUT Current or pulse and 5 DO3 Relay OUTPUT /LPS Current and 5 DO DO Alarm Alarm *: If the setup parameter DIS (DI function selection) is set to, when the contact input is ON (run state), that controller outputs the preset output value. Legend Terminal Parameter Function Analog signal Contact signal Front panel key All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition Jul. 30, 0000

0 Standard Type, Terminal Arrangements Control output * Wiring can only be carried out for controllers with V DC loop power supply. V DC loop power supply Note: Select this option from the OT parameter. * Time proportional PID relay contact output is configured at factory before shipment. Relay contact output NC RS85 communication * Wiring can only be carried out for controllers with communication functions. Maximum baud rate: 9600 bps NO RTD input TC input A b 3 SDB() 3 B 3 Receiving 0 ma DC Current input * Not configured at factory before shipment Signals with the Controller * When receiving 0 ma DC current signals, See. Initial Settings, for more information. set the input type to 5 V DC (setpoint ). 50 Ω 0mA 3 SDA() mv/v input Contact rating: 50 V AC, 3 A 30 V DC, 3 A (resistance load) Note: Connecting a 50 Ω resistor to the is optional. Model: X0050 (resistor with M3.5 crimpon terminal lugs) RDB() 5 RDA() 6 UT 6.68.0VDC (30 ma DC max.) Alarm output Alarm output 3 SG 7 5 Alarm output Relay 3 Alarm3 output * retransmission is configured at factory before shipment. Retransmission output 7 Relay contact rating: 0 V AC, A 30 V DC, A (resistance load) 0 ma DC Control output 5 Note:Select this option from the OT parameter. Current/voltage pulse output Power supply CAUTION Load resistance: 600 Ω or less Before carrying out wiring, turn off the power to the controller and check that cables to be connected are not alive with a tester or the like because there is a possibility of electric shock. Power supply * If 5 V DC loop power supply is used, retransmission output cannot be used. 5 V DC loop power supply 8 L 0 ma DC, voltage pulse ( V) 6 9 N.58.0VDC ( ma DC max.) 7 3 5 6 7 8 9 0 5 6 7 8 9 30 3 5 6 7 8 9 0 5 0 Allowable range: 00 to 0 V AC ( 0%) * DIS is a setup parameter. (free voltage) 50/60 Hz shared Changing DIS setpoint allows you to change the function of external contact input. Contact Transistor contact 5V Correspondence between parameter DIS and external contact input functions UT DI When DIS= When DIS=3 When DIS= When DIS= (Factoryshipped setting) When DIS=OFF 9 DI 5V 9.SP when DI=ON.SP when DI=OFF When switching target SP to : CT * This wiring is only Heater current possible for a controller detection input with a heater burnout alarm. 9.SP.SP3.SP.SP Hides the LOCK parameter when DI=ON. Shows the LOCK parameter when DI=OFF..SP when DI=ON.SP when DI=OFF No function DI OFF ON OFF ON OFF OFF ON ON DI DI CT 8 CT 8 8 DI STOP when DI=ON RUN when DI=OFF No function AUTO when DI=ON MAN when DI=OFF No function CT 0 0 30 Contact rating: V DC, 0 ma or more Note: External Contact Input If the power is turned on when the external contact input is OFF, the mode (SP.NO or ) existing before the power is turned off will be continued. (except for RUN/STOP) * OT is a setup parameter. You can change the settings of the parameter OT to change the control output type. See. Initial Settings, for more information. Correspondence between parameter OT and control output types OT=3 OT= OT= OT=0 (factoryshipped setting) Onoff control Relay output (, and ) 3 6 7 6 7 3 Current output Time proportional control Voltage pulse output Time proportional control Relay output (, and ) All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition Jul. 30, 0000

<<Contents>> <<Index>> Heating/Cooling, Terminal Arrangements Receiving 0 ma DC Current Signals with the Controller Heatingside control output * When receiving 0 ma DC current signals, input * Not configured at factory before shipment TC input RTD input A b 3 3 B * Wiring can only be carried out for controllers with communication functions. Maximum baud rate: 9600 bps RS85 communication Relay contact output * Time proportional PID relay contact set the input type to 5 V DC (setpoint ). output is configured at factory before shipment. * Available if, 7 or 0 is set in the OT (Control Output Type) setup parameter. NC SDB() 5 6 7 NO 50 Ω 0mA SDA() 3 3 RDB() mv/v input RDA() Contact rating: 50 V AC, 3 A 30 V DC, 3 A (resistance load) Note: Connecting a 50 Ω resistor to the is optional. Model: X0050 (resistor with M3.5 crimpon terminal lugs) SG 3 * retransmission is configured at factory before shipment. 5 V DC loop power supply Retransmission output Note: The coolingside control output is selected if, 5 or 6 is set in the OT (Control Output Type) setup parameter. The alarm3 output is not available. The controller is factoryset to the coolingside control output (time proportional PID relay contact output). UT Alarm output/coolingside control output Alarm output Alarm output 5.58.0VDC ( ma DC max.) 0 ma DC 5 Heatingside control output Current/voltage pulse output * If 5 V DC loop power supply is used, retransmission output cannot be used. * Available if 5, 6, 8, 9, or is set in the OT (Control Output Type) setup parameter. CAUTION Power supply Power supply L Before carrying out wiring, turn off the power to the controller and check that cables to be connected are not alive with a tester or the like because there is a possibility of electric shock. * The retransmission output and 5 V DC loop power supply are not available if the coolingside control output is set to continuous output and voltage pulse output. 0 ma DC, voltage pulse ( V) 6 7 3 5 6 7 8 9 0 5 6 7 8 9 30 Relay 3 Alarm3 output or coolingside control output (Note) 6 5 7 Relay contact rating: 0 V AC, A 30 V DC, A (resistance load) N 5 8 9 3 5 6 7 8 9 0 0 Allowable range: 00 to 0 V AC ( 0%) (free voltage) 50/60 Hz shared * DIS is a setup parameter. Changing DIS setpoint allows you to change the function of external contact input. Contact Transistor contact 5V Correspondence between parameter DIS and external contact input functions UT DI When DIS=.SP when DI=ON.SP when DI=OFF When DIS=3 When DIS= When DIS= (Factoryshipped setting) When DIS=OFF Heater current detection input 9 8 0 DI DI When switching target SP to : * This wiring is only possible for a controller with a heater burnout alarm. 5V 9 8 0.SP.SP3.SP.SP Hides the LOCK parameter when DI=ON. Shows the LOCK parameter when DI=OFF..SP when DI=ON.SP when DI=OFF No function CT DI STOP when DI=ON RUN when DI=OFF OFF ON OFF ON OFF OFF ON ON DI DI No function AUTO when DI=ON MAN when DI=OFF No function CT 9 8 CT CT 30 Contact rating: V DC, 0 ma or more * Wiring can only be carried out for controllers with V DC loop power supply. V DC Power Supply Wiring to Twowire Sensor 5 V DC Power Supply Wiring to Twowire Sensor * OT is a setup parameter. You can change the settings of the parameter OT to change the control output type. Coolingside control output 0 ma DC, voltage pulse ( V) Note: External Contact Input If the power is turned on when the external contact input is OFF, the mode (SP.NO or ) existing before the power is turned off will be continued. (except for RUN/STOP) Correspondence between parameter OT and heatingside/coolingside output types OT= (factoryshipped setting) OT=5 OT=6 Heating side: Current output Heating side: Voltage pulse output input 0. to.0 V DC signal Cooling side: Relay output Cooling side: Relay output OT=7 OT=8 OT=9 6 7 6 7 Heating side: Relay output (, and ) input to 5 V DC signal 3 50 External resistor (Note) 00 External resistor (Note) 7 7 7 Cooling side: Relay output 3 3 Heating side: Current output Heating side: Voltage pulse output 6 7 6 7 Heating side: Relay output (, and ) 3 Cooling side: Voltage pulse output Cooling side: Voltage pulse output Cooling side: Voltage pulse output Twowire transmitter Twowire transmitter OT=0 OT= OT= 5 5 5 Loop power supply.6 to 8.0 V DC Loop power supply.5 to 8.0 V DC Heating side: Current output Heating side: Voltage pulse output 0 ma DC 0 ma DC 6 7 Cooling side: Current output 6 7 Heating side: Relay output (, and ) 3 5 Cooling side: Current output Cooling side: Current output 5 5 5 The control output types, relay output and voltage pulse output shown in the table above refer to those of time proportional control. To change the type to a relay output for onoff control, select Relay Terminals and change the setpoint of the proportional band to 0. Note: Connecting a 50 resistor to the is optional. Model: X0050 (resistor with M3.5 crimpon terminal lugs) Note: Connecting a 00 resistor to the is optional. Model: X0000 (resistor with M3.5 crimpon terminal lugs) All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition Jul. 30, 0000

External Dimensions and Panel Cutout Dimensions Unit: mm 8 00 Small bracket Small bracket to 0 mm (Panel thickness) [(N) 85] 0.6 0 9 0.8 0 96 9.8 General installation 70 min. Sidebyside close installation (53) 5 min. 0.8 9 0 "N" stands for the number of controllers to be installed. However, the measured value applies if N 5. 5 0.6 0 (5) Model and Suffix codes Model Suffix Code Description UT30 Digital indicating controller (provided with retransmission output and 5 V DC loop power supply as standard) Type Optional functions 0 Standard type Heating/cooling type 3 Standard type (with V DC loop power supply) 0 None With communication, heater burnout alarm With heater burnout alarm Standard accessories: Brackets (mounting hardware), Unit label, User s manuals, and User s Manual (reference) (CDROM version) Items to be specified when ordering Model and suffix codes, necessary/unnecessary of User s Manual or QIC. All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition Jul. 30, 0000