INSTALLATION INSTRUCTION RRU Double Light Pole Mount for installation of two RRU units on mast, towers or other vertical structures. CUE DEE YOUR INNOVATIVE PARTNER 1
CONTENTS 1. PRODUCT COVERED IN THIS INSTALLATION INSTRUCTION... 2 2. RECOMMENDED TOOLS... 2 3. PARTS INCLUDED... 3. PACKAGE DIMENSIONS... 3 5. ASSEMBLY OF THE MOUNT.... CLAMP MOUNTING RANGE... 8 1. PRODUCT COVERED IN THIS INSTALLATION INSTRUCTION This installation instruction covers the RRU Double Light Pole Mount. The bracket is made of anodized aluminium and the fasteners are made of acid proof stainless steel. This instruction shows how the bracket is assembled, mounted towards the RRU units and installed on mast, towers or other vertical structures. 2. RECOMMENDED TOOLS Torque wrench 17 mm open-ended spanner (M10) 17 mm socket (M10) 2 CUE DEE YOUR INNOVATIVE PARTNER
1 2 5 5 3 3. PARTS INCLUDED ITEM: QTY: ART. NO: DESCRIPTION: STANDARD: 1 2 7358 Clamp, front 2 2 7359 Clamp, back 3 2 78 Z-angle 11 Threaded Rod M10x210 A-70 DIN 97 5 12 1308 Washer 10,5 A DIN 125-A 20 1395 Nut M10 A-80 DIN 93 7 1322 Bolt M10x35 A-80 DIN 933. PACKAGE DIMENSIONS 7 5 ART. NO. IDENTIFICATION SIZE (mm) WEIGHT (kg) 783 RRU Double Light Pole Mount 300 x 95 x 95 3,0 CUE DEE YOUR INNOVATIVE PARTNER 3
5. ASSEMBLY OF THE MOUNT STEP 1 ~ 0 mm Pre-assemble the nuts on the threaded rods. Let there be approx 0 mm distance between the end of threaded rod and the nut like fig. STEP 2 1 Mount the front clamp on the backside of the first RRU unit by screwing in the threaded rods like fig. CUE DEE YOUR INNOVATIVE PARTNER
STEP 3 1 M10 INSERT Screwing in the threaded rod is done easily by hand into the M10 insert on the backside of the RRU. Make sure you screw the threaded rod to the bottom of the insert. STEP Control Measurement Not longer than 170 mm M10 INSERT Note! The depth of the insert can vary between different types of RRU, ensure that instructed control measurement never exceeds 170 mm. After checking measurement tighten the nuts to 33 Nm. CUE DEE YOUR INNOVATIVE PARTNER 5
STEP 5 5 2 Pre-assemble the rear clamps, in total four washers and eight nuts on the threaded rods. Make sure that the rear clamps are turned in right position depending on the shape and size of the tower leg as shown in figure Clamp Mounting Range. Do not tighten the nuts at this stage. STEP The first RRU unit is now ready to be lifted up and attached to the pole. Close the rear clamps and mount the unit on the pole and tighten all nuts to 33 Nm. CUE DEE YOUR INNOVATIVE PARTNER
STEP 7 Mount the z-angles to the second RRU unit. Tighten the screws to 33 Nm. STEP 8 Lift the second RRU unit to the pole and hang the z-angles onto the free end of the threaded rods. Mount the rest of the washers and nuts on the threaded rods. Tighten the nuts to 33 Nm. CUE DEE YOUR INNOVATIVE PARTNER 7
. CLAMP MOUNTING RANGE ROUND TUBES Ø25-120 mm (1,0-,7 inch) 1 For tubes Ø25-0 mm the back clamp profile should be turned with the protruding lips towards the tube. For tubes Ø0-120 mm the lips should be turned away from the tube. Min Ø25 mm 1 Max Ø120 mm 1) The threaded rods must be shortened for tubes Ø25-55 mm. Ø25-0 mm Ø0-120 mm SQUARE PROFILES 35x35-90x90 mm (1,x1,-3,5x3,5 inch) 2 For square profiles 35x35 to 50x50 mm the back clamp profile should be turned with the protruding lips towards the frame member. For squares 50x50 to 90x90 mm the lips should be turned away from the frame member. 2) The threaded rods must be shortened for squares 35x35-50x50 mm. Min 35x35 mm 2 Max 90x90 mm 35x35 to 50x50 mm 50x50 to 90x90 mm 90 ANGLE PROFILES 35x35-90x90 mm (1,x1,-3,5x3,5 inch) 3 For 90 angle frame legs the back clamp profile should be turned with the protruding lips towards the frame member. Min 35x35 mm 3 Max 90x90 mm 3 3) The threaded rods must be shortened when used on 90 angle profiles. 0 ANGLE PROFILES 0-100 mm (1,-,0 inch) For 0 angle frame legs turn the back profile with the protruding lips away from the frame member. Min opening 0 mm Max opening 100 mm ) The threaded rods must be shortened when used on 0 angles 0-90 mm. 8 CUE DEE YOUR INNOVATIVE PARTNER