Zelio Time - timing relays

Similar documents
Zelio Time - Timing Relays NFC Timing Relay

Chronos 2 electronic timers - Plug-in 8-pin (35 mm)

Chronos 2 electronic timers mm

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RENF22R2MMW Zelio Timer Relay - Modular

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

17.5mm Chronos 2 Timers

RE Product data sheet Characteristics. universal plug-in timing relay V AC - 1 C/O. Main. Complementary. Discrete output type

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

Electronic timers CT-S range Selection and ordering details

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

22/10/2012

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

05/09/2014

PART NUMBERING SYSTEM

PART NUMBERING SYSTEM

Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start

02/11/2015

Multi-function 11 pin Plug-in for use with 90 series sockets

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Compact Preset Counter

Multi-function 11 pin Plug-in for use with 90 series sockets

Relais und Automatisierungssysteme JUST IN TIME. with the. New Generation NGG. from Schleicher NGG CATALOGUE

Programmable Digital Timer

Type Nominal voltage (V) Code HSV V

RE17LLBM asymmetrical flashing relay s V AC - solid state output

11/03/2013

24/07/2012

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

DZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

VAC V AC/DC, +/-10%, 45-65Hz Hz VDC max 1W ; 24VAC 2.5VA, 48VAC 4.46VA ; 110VAC 1.76 VA ; 220VAC 2.53 VA

Modular timers A

02/11/2015

02/11/2015

Electronic timer CT-MFS.21

Multi Function Timer with Free power, Compact size W38 H42mm

83 SERIES. 83 Series - Modular timers A. Features

08/07/2015

Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA General Inquiries: (800)

T ime Delay Relays General information

onlinecomponents.com

08/07/2015

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

U1601 ENERGY CONTROL SYSTEM

02/11/2015

For more information, please visit or call toll free at

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750

05/09/2012

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

XIOC technology and networking modules

Control Relays and Timers

1 Connector X14270, 47-pin 2 Plug connector to distribution box X4010, 23-pin. 3 Connector X14271, 54-pin 4 Connector X14272, 54-pin

MULTI-RANGE ANALOG TIMER

DIGEM f 96 x 48 EK. Applications. Description

02/11/2015

Multi-voltage Multi-function. Wiring diagram (without control signal)

S D 1 Operating Instructions

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

FM COUNTER MODULE

362 Umbilo Road, Durban 4001, P.O Box 17211, Congella 4013, Tel: /8, Fax: Website:

Section. Timers. Selection Guide... G-2. Timing Diagrams Overview... G-4. W G RTE Series Analog Timers... G-8 Accessories... G-11 Dimensions...

Bulletin 700-HX Multifunction Digital Timing Relay

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

EY-EM 527: Remote I/O module, ecolink527

Panasonic products. SIngle function-multirange Multifunction single-range Multifunction-multirange. Precise High quality.

Pulse Scaler for DIN Rail Attachment

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Analog Timer TTL Series

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Programmable Digital Timer

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Universal Controller

83 Series - Modular timers 16 A. Features

Technical Data Sensor Input Input voltage measuring range (FSO) V 0 ±10 Max. input voltage V <±15 Resolution mv 5 with oversampling 14 Bit mv

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Solid-state Timer H3DS

DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS

Timers RTE. RTE Series Analog Timers

CN Series Specially Time Delay Relays SFR Serie Amplifier Relays, Switching Amplifier SBV Amplifier Blinker CPF Pulse Shaper CCX Preset Counters

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Assembly of Contacts 700-FS A 3 A U23. Function Contact Outputs Time Ranges Supply Voltages All functions: Z12 12V DC

Liquid level monitors and controls

Modular equipment. Presentation, standards. Standard contactors TeSys GC

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

Transcription:

Presentation Zelio ime - timing relays DIN rail mounted relays Presentation A timing relay is a component which is designed to time events in industrial automation systems by closing or opening contacts before, during or after a set timing period. here are two main 'families' of timing relays: b "DIN rail mounted" relays (E7, E8, E9, E17, EXL ) designed for mounting on DIN rails in an enclosure, b "Panel mounted" relays type E48A designed for mounting on the front of a panel to give users easy access to the settings. E17 E7, E8, E9 EXL Panel mounted relays hese relays have one, two or four outputs. Sometimes the second output can be either timed or instantaneous. If the power is switched off during the timing period, the relay reverts to its initial position. Application examples: b opening of automatic doors, b alarm, b lighting in toilets, b car park barriers... E48A Definitions he following definitions will assist in understanding the operation of these relays: b elay output: his is the most common type of output. When the relay is energized, the moving armature is attracted by the coil and so actuates the contacts, which change state. When the relay is de-energized, both the armature and the contacts revert to their initial position. his type of output allows complete isolation between the supply and the output. here are three types of output: /O: changeover contact, i.e. when the relay is de-energized, the N circuit between the common point and N/ is closed and when the relay is operating (coil energized), it closes the circuit between NO the common point and N/O. N/: a contact that is closed without being actuated is called a Normally losed (N/) contact. N/O: a contact that closes when actuated is called a Normally Open (N/O) contact. N NO b Solid state output: hese outputs are entirely electronic and involve no moving parts; service life is therefore increased. b Breaking capacity: he current value that a contact is capable of breaking in specifi ed conditions. b Mechanical durability: he number of mechanical operating cycles of the contact or contacts. b Minimum switching capacity (or minimum breaking capacity): corresponds to the minimum required current which can fl ow through the contacts of a relay. b G (Gate) Input: Gate input allows timing in progress to be interrupted without resetting it. 2

Presentation (continued) Zelio ime - timing relays Definitions (continued) Functions iming functions are identifi ed by letters. Main timing functions A (2) B (2) (2) D (2) H (2) K L (2) N O P W omplementary functions Ac Ad Ah Ak At Aw Bw Di (2) He Ht Li (2) Lt Pt Qc Qe Qg Qt t Definitions Power on delay relay On-delay and off-delay relay with control signal Pulse delayed relay with control signal Pulse delayed relay (single cycle) with control signal Asymmetrical On-delay and Off-delay with external control Power on delay relay (summation) with control signal Off-delay on energization or on opening of control contact Interval relay with control signal Double interval relay with control signal Off-delay relay with control signal Symmetrical fl asher relay (starting pulse off) Symmetrical fl asher relay (starting pulse on) Interval relay Pulse-on de-energization Interval relay (summation) with control signal Delay on de-energization (without auxiliary supply) Asymmetrical fl asher relay (starting pulse off) Asymmetrical fl asher relay (starting pulse on) Asymmetrical fl ashing with partial stop of timing etriggerable interval relay with control signal on etriggerable interval delayed relay with control signal on Pulse delayed relay with fi xed pulse length Pulse delayed relay (summation and fi xed pulse length) with control signal off Star-delta timing Star-delta timing Star-delta timing Star-delta timing Bistable relay with control signal on etriggerable bistable relay with control signal on Interval relay with control signal off omplementary functions enhance the main timing functions. Example: Ac: timing after closing and opening of control contact. (2) he most commonly used timing functions. 3

Selection Zelio ime - timing relays Selection table Selection criteria b Functions (On-delay or Off-delay, counter, fl ashing ) b Supply voltage (example: a/c 12 V 240 V). b iming range for a timing relay (example: 0.05 s ) b ype of output (contact or solid state) and required Number of contacts. b Breaking capacity or ated current of contacts, expressed in Amperes. his is the maximum current which may fl ow through the contacts. Functions iming range Supply voltage ype of output ated current A 0.1 s c 12 V 2 /O contacts 5 A EXL2MJD 4 /O contacts 3 A EXL4MJD 0.1 s c 24 V 2 /O contacts 5 A EXL2MBD 4 /O contacts 3 A EXL4MBD 0.1 s a 24 V 2 /O contacts 5 A EXL2MB7 4 /O contacts 3 A EXL4MB7 0.1 s a 120 V 2 /O contacts 5 A EXL2MF7 4 /O contacts 3 A EXL4MF7 0.1 s a 230 V 2 /O contacts 5 A EXL2MP7 4 /O contacts 3 A EXL4MP7 0.1 s 10 s a/c 24 240 V 1 solid state output 0.7 A E9A11MW 0.3 s 30 s 0.7 A E9A31MW 3 s 300 s 0.7 A E9A21MW 40 s 60 min 0.7 A E9A51MW 1 s 0.7 A E17LAMW 0.02 s 300 h 2 timed /O contacts 5 A E48AM12MW 0.05 s 300 h a/c 24 V, V 1 /O contact 8 A E7L11B 0.1 s 3 s 8 A E8A61BQ 0.1s 10 s 8 A E8A11BQ 0.3 s 30 s 8 A E8A31BQ 3 s 300 s 8 A E8A21BQ 20 30 min 8 A E8A41BQ 0.05 s 300 h a/c 24 V, V, 2 /O contacts 8 A E7P13B Ac, At, B, Bw,, D, Di, H, Ht 1 s a 24 240 V 1 solid state output 0.7 A E17LMBM 1 s a/c 12 V 1 /O contact 8 A E17MJ 1 s a/c 12 240 V 1 /O contact 8 A E17MMW 8 A E17MMWS 1 s c 24 V, a 24 240 V 1 /O contact 8 A E17MM At 1 s c 24 V, a 24 240 V 1 /O contact 8 A E17AM At, Aw 0.05 s 300 h V, a/c 24 V, 1 /O contact 8 A E7M11B At, B,, D, Di, H, Ht 1 s 10 h c 24 V, a 24 240 V 1 /O contact 8 A E17MEM B,, Di 0.02 s 300 h a/c 24 240 V 2 /O contacts 5 A E48AML12MW elay, D, Di, H, Qg, Qt, W 0.05 s 300 h V, a/c 24 V, 2 /O contacts 8 A E7MY13B 0.05 s 300 h a/c 24 240 V 2 /O contacts 8 A E7MY13MW, D, Di, H, W 0.05 s 300 h V, a/c 24 V, D, Di, H 0.1 s 10 s and 3 s 300 s a/c 24 240 V a 24 240 V 1 /O contact 8 A E7ML11B 1 solid state output 0.7 A E9MS21MW A1, A2, H1, H2 0.02 s 300 h a/c 24 240 V 2 /O contacts 5 A E48AMH13MW Ac 0.05 s 300 h V, a/c 24 V, 1 /O contact 8 A E7MA11B 2 /O contacts 8 A E7MA13B Ad, Ah, N, O, P, Pt,, t, W 1 s c 24 V, a 24 240 V 1 /O contact 8 A E17MXM Ak 0.05 s 300 h V, a/c 24 V, 1 /O contact 8 A E7MV11B 4

Selection (continued) Zelio ime - timing relays Selection table (continued) Functions iming range Supply voltage ype of output ated current B 1 s c 24 V, a 24 240 V 1 /O contact 8 A E17BM 0.1 s 10 s a/c 24 V 1 /O contact 8 A E8A11BQ 0.3 s 30 s 8 A E8A31BQ 3 s 300 s 8 A E8A21BQ 1 s c 24 V, a 24 240 V 1 /O contact 8 A E17M 0.1 s 10 s V 1 /O contact 8 A E8A11FQ 0.3 s 30 s 8 A E8A31FQ 3 s 300 s 8 A E8A21FQ 20 s 30 min 8 A E8A41FQ 0.05 s 300 h a/c 24 V, V, 1 /O contact 8 A E7A11B 8 A E7M11B 2 /O contacts 8 A E7L13B 0.1 s 10 s a 24 240 V 1 solid state output 0.7 A E9A11MW7 0.3 s 30 s 0.7 A E9A31MW7 3 s 300 s 0.7 A E9A21MW7 40 s 60 min 0.7 A E9A51MW7 1 s 0.7 A E17LBM D 0.05 s 300 h a/c 24 V, V 1 /O contact 8 A E7L11B 0.1 s 10 s 8 A E8L11BQ 0.05 s 300 h a/c 24 V, V, 2 /O contacts 8 A E7P13B H 0.05 s 300 h a/c 24 V, V 1 /O contact 8 A E7PE11B 0.1 s 10 s 8 A E8PE11BQ 0.3 s 30 s 8 A E8PE31BQ 3 s 300 s 8 A E8PE21BQ 0.05 s 300 h a/c 24 V, V, 2 /O contacts 8 A E7PP13B 1 s a 24 240 V 1 solid state output 0. 7 A E17LHBM H, Ht 1 s c 24 V, a 24 240 V 1 /O contact 8 A E17HM He 0.05 s 0.5 s a/c 24 V, V 1 /O contact 8 A E8P01BQ K 0.05 s 10 min a/c 24 240 V 1 /O contact 5 A E7B11MW 0.05 s 0.5 s a/c 24 V, V 1 /O contact 8 A E8B51BQ 0.1 s 10 s 8 A E8B11BQ 0.3 s 30 s 8 A E8B31BQ 0.05 s 10 min a/c 24 240 V 2 /O contacts 5 A E7B13MW L, Li 1 s c 24 V, a 24 240 V 1 /O contact 8 A E17LM 1 s a 24 240 V 1 solid state output 0.7 A E17LLBM 1 s a/c 12 V 1 /O contact 8 A E17LJ 0.02 s 300 h a/c 24 240 V 2 timed /O contacts 5 A E48AV12MW L, Li, Lt 0.05 s 300 h V, a/c 24 V, 1 /O contact 8 A E7V11B Qc 0.1 s 10 s a/c 24 V, V 1 /O contact 8 A E8YG11BQ 0.3 s 30 s 8 A E8YG31BQ 3 s 300 s 8 A E8YG21BQ Qe 0.3 s 30 s a/c 24 V 1 NO + 1 N 8 A E8YA32BQ 0.3 s 30 s V 1 NO + 1 N 8 A E8YA32FQ 0.3 s 30 s a 380 415 V 1 NO + 1 N 8 A E8YA32QQ Qg 0.05 s 300 h a/c 24 V, V, 1 NO + 1 N 8 A E7Y12B Qt 0.05 s 300 h a/c 24 V, V, 2 /O contacts 8 A E7YA12Bè+ W 0.1 s 10 s a/c 24 V 1 /O contact 8 A E8PD11BQ 0.3 s 30 s 8 A E8PD31BQ 3 s 300 s 8 A E8PD21BQ 0.1 s 10 s V 1 /O contact 8 A E8PD11FQ 0.3 s 30 s 8 A E8PD31FQ 3 s 300 s 8 A E8PD21FQ 0.05 s 300 h a/c 24 V, V, 2 /O contacts 8 A E7PD13B W, Ht 0.05 s 300 h a/c 24 V, V, 1 /O contact 8 A E7PM11B elay 5

Functions Zelio ime - timing relays Functions : Supply : elay or solid state output 1/2: 2 timed outputs 2 inst.: he second output is instantaneous if the right position is selected : iming period : ontrol contact G: Gate a: Adjustable On-delay r: Adjustable Off-delay Function A: Power on delay relay 1 output 2 outputs Function diagram : elay de-energized elay energized Output open Output closed 1/2 he timing period begins on energization. After timing, the output(s) close(s). he second output can be either timed or instantaneous. 2 timed outputs (1/2) or 1 timed output and 1 instantaneous output (2 inst.). Function Ac: On-delay and off-delay relay with control signal 1 output 2 outputs G = t1 + t2 + = t 1 + t 2 + Function Ad: Pulse delayed relay with control signal t1 t2 t'1 t'2 2 inst. 1/2 2 inst. 2 timed outputs (1/2) or 1 timed output and 1 instantaneous output (2 inst.). After power-up, closing of the control contact causes the timing period to start (timing can be interrupted by operating the Gate control contact G). At the end of this timing period, the relay closes. When control contact re-opens, the timing starts. At the end of this timing period, the output reverts to its initial position (timing can be interrupted by operating the Gate control contact G). he second output can be either timed or instantaneous. After power-up, pulsing or maintaining control contact starts the timing. At the end of this timing period, the output closes. he output will be reset the next time control contact is pulsed or maintained. Function Ah: Pulse delayed relay (single cycle) with control signal After power-up, pulsing or maintaining control contact starts the timing. A single cycle then starts with 2 timing periods of equal duration (start with output in rest position). Output changes state at the end of the fi rst timing period and reverts to its initial position at the end of the second timing period. ontrol contact must be reset in order to re-start the single fl ashing cycle. 6

Functions (continued) Zelio ime - timing relays Functions (continued) Function Ak: Asymmetrical On-delay and Off-delay with external control After power-up and closing of the control contact, timing starts for a period a (timing can be interrupted by operating the Gate control contact G). At the end of this timing period a, the output closes. Opening of control contact causes a second timing period r to start (timing can be interrupted by operating the Gate control contact G). At the end of this timing period r, the output reverts to its initial state. G t1 t2 t'1 t'2 a = t1 + t2 + r = t 1 + t 2 + Function At: Power on delay relay (summation) with control signal After power-up, the fi rst opening of control contact starts the timing. iming can be interrupted each time control contact closes. When the cumulative total of time periods elapsed reaches the pre-set value, the output relay closes. t1 t2 = t1 + t2 + Function Aw: Off-delay on energization or on opening of control contact he timing period starts on energization. At the end of the timing period, the output closes. losing of the control contact makes the output open. Opening of control contact restarts timing period. At the end of the timing period, the output closes. Function B: Interval relay with control signal After power-up, pulsing or maintaining control contact starts the timing. he output closes for the duration of the timing period then reverts to its initial state. Function Bw: Double interval relay with control signal On closing and opening of control contact, the output closes for the duration of the timing period. 7

Functions (continued) Zelio ime - timing relays Functions (continued) Function :Off-delay relay with control signal 1 output 2 outputs 1/2 After power-up and closing of the control contact, the output closes. When control contact re-opens, timing starts. At the end of the timing period, output(s) revert(s) to its/their initial state. he second output can be either timed or instantaneous. 2 inst. 2 timed outputs (1/2) or 1 timed output and 1 instantaneous output (2 inst.). Function D: Symmetrical flasher relay (starting pulse off) 1 output 2 outputs 1/2 epetitive cycle with two timing periods of equal duration, with output(s) changing state at the end of each timing period. he second output can be either timed or instantaneous. 2 inst. 2 timed outputs (1/2) or 1 timed output and 1 instantaneous output (2 inst.). Function Di: Symmetrical flasher relay (starting pulse on) 1 output 2 outputs 1/2 epetitive cycle with two timing periods of equal duration, with output(s) changing state at the end of each timing period. he second output can be either timed or instantaneous. 2 inst. 2 timed outputs (1/2) or 1 timed output and 1 instantaneous output (2 inst.). Function H: Interval relay 1 output 2 outputs 1/2 On energization of the relay, timing period starts and the output(s) close(s). At the end of the timing period, output(s) revert(s) to its/their initial state. he second output can be either timed or instantaneous. 2 inst. 2 timed outputs (1/2) or 1 timed output and 1 instantaneous output (2 inst.). 8

Functions (continued) Zelio ime - timing relays Functions (continued) Function He: Pulse-on de-energization On de-energization, the output closes for the duration of a timing period. > 80 ms 80 ms < Function Ht: Interval relay (summation) with control signal On energization, the output closes for the duration of a timing period then reverts to its initial state. Pulsing or maintaining control contact will again close the output. iming is only active when control contact is released and so the output will not revert to its initial state until after a time t1 + t2 +. he relay memorises the total, cumulative opening time of control contact and, once the set time is reached, output reverts to its initial state. t1 t2 = t1 + t2 + Function K: Delay on de-energization (without auxiliary supply) 1 output 2 outputs On energization, the output(s) close(s). On de-energization, timing period starts and, at the end of this period, the output(s) revert to its/their initial state. 1 2 Function L: Asymmetrical flasher relay (starting pulse off) epetitive cycle consisting of two, independently adjustable timing periods a and r. Each timing period corresponds to a different state of the output. r a Function Li:Asymmetrical flasher relay (starting pulse on) epetitive cycle consisting of two, independently adjustable timing periods a and r. Each timing period corresponds to a different state of the output. a r Function Lt: Asymmetrical flashing with partial stop of timing epetitive cycle comprises of two, independently adjustable timing periods a and r. Each timing period corresponds to a different state of the output. Gate control contact G can be operated to partially stop timing periods a and r. G t1 t2 t'1 t'2 r = t1 + t2 + a = t 1 + t 2 + 9

Functions (continued) Zelio ime - timing relays Functions (continued) Function N: etriggerable interval relay with control signal on After power-up and an initial control pulse, the output closes. If the interval between two control pulses is greater than the set timing period, timing elapses normally and the output opens at the end of the timing period. If the interval is not greater than the set timing period, the output remains closed until this condition is met. Function O: etriggerable interval delayed relay with control signal on An initial timing period begins on energization. At the end of this timing period, the output closes. As soon as there is a control pulse, the output reverts to its initial state and remains in that state until the interval between two control pulses is less than the value of the set timing period. Otherwise, the output closes at the end of the timing period. t< Function P: Pulse delayed relay with fixed pulse length he timing period starts on energization. At the end of this period, the output closes for a fi xed time P. P = 500 ms P Function Pt: Pulse delayed relay (summation and fixed pulse length) with control signal off On energization, timing period starts (it can be interrupted by operating control contact ). At the end of this period, the output closes for a fi xed time P. t1 = t1 + t2 + P = 500 ms t2 Function Qc: Star-delta timing P iming for star delta starter with contact for switching to star connection. 50 ms Function Qe: Star-delta timing On energization, the star contact closes instantly and timing starts. At the end of the timing period, the star contact opens. After a 80 ms pause, the delta contact closes and remains in this position. 1 2 80 ms 10

Functions (continued) Zelio ime - timing relays Functions (continued) Function Qg: Star-delta timing iming for star delta starter with contact for switching to star connection. 1 2 50 ms Function Qt: Star-delta timing iming for star-delta starter with double On-delay period. 1 2 50 ms Function : Bistable relay with control signal on After power-up, pulsing or maintaining of control contact switches the output on. A second pulse on the control contact switches the output off. Function t: etriggerable bistable relay with control signal on After power-up, pulsing or maintaining control contact switches output on and starts timing. he output switches off at the end of the timing period or following a second pulse on the control contact. t< Function W: Interval relay with control signal off 1 output 2 outputs After power-up and opening of the control contact, the output(s) close(s) for a timing period. At the end of this timing period the output(s) revert to its/their initial state. he second output can be either timed or instantaneous. 1/2 2 inst. 2 timed outputs (1/2) or 1 timed output and 1 instantaneous output (2 inst.). 11

Functions (continued) Zelio ime - timing relays Electronic relays, relay output, 48 x 48 E48AM12MW Function A: Delay on energization n E48AV12MW Function L: Asymmetrical flashing, start with output in rest position Function Li: Asymmetrical flashing, start with output in operating position n n Gate Gate 2-6 Nor / Inv 2-6 Nor / Inv on on t2 tb on on t2 tb off off t1 t3 ta tc off off t1 t3 ta t1 off = t1+t2+t3 on = ta+tb+tc on = t1+t2+t3 off = ta+tb+tc E48AML12MW Function A: Delay on energization Function B: iming on impulse, one shot n Start Gate eset n Start Gate eset t1 t2 t3 t t1 t3 t2 = t1 + t2 + t3 = t1 + t2 + t3 Function : iming after opening of control contact Function Di: Symmetrical flashing, start with output in operating position n Start Gate eset n Start Gate eset Ouput Output = t1 + t2 + t3 t1 t3 t2 t1 t2 t1t2 = t1 + t2 12

Functions (continued) Zelio ime - timing relays Electronic relays, relay output, 48 x 48 E48AMH13MW Functions A1, A2: Delay on energization Functions H1, H2: Pulse-on energization n 2 n 2 1 1 Note: If A1 or H1 is selected, only 2 is timed, 1 is instantaneous 13

eferences Zelio ime - timing relays Modular relays with solid state or relay output, width 17.5 mm/0.69 in. PF121100A Solid state output v Multifunction, dual function or single function v Multi-range (7 selectable ranges) v Multivoltage v Solid state output: 0.7 A v Screw terminals E17LAMW PF121103B E17LLBM elay output, 1 /O contact v Dual function or single function v Multi-range (7 selectable ranges) v Multivoltage v 1 relay output: 8 A v Screw terminals v State indication by 1 LED v Option of supplying a load in parallel v 3-wire sensor control option Modular relays with solid state output 0.7 A Single function iming ranges Functions Voltages eference Weight V kg/lb Dual function Multifunction A z 24 240 E17LAMW 0.060/ 0.132 H a 24 240 E17LHBM 0.060/ 0.132 a 24 240 E17LBM 0.060/ 0.132 L, Li At, B,, H, Ht, D, Di, Ac, Bw a 24 240 E17LLBM 0.060/ 0.132 a 24 240 E17LMBM 0.060/ 0.132 Modular relays with relay output, 1 /O contact Single function iming ranges Functions Voltages eference Weight V kg/lb B c 24 / a 24 240 E17BM 0.070/ c 24 / a 24 240 E17M 0.070/ PF121113A E17pMp Dual function Multifunction 1 min 10 h At H, Ht L, Li At, B,, H, Ht, D, Di, Ac, Bw Ad, Ah, N, O, P, Pt,, t, W At, B,, H, Ht, D, Di c 24 / a 24 240 E17AM 0.070/ c 24 / a 24 240 E17HM 0.070/ c 24 / a 24 240 E17LM 0.070/ z 12 E17LJ 0.070/ z 12 E17MJ 0.070/ c 24 / a 24 240 E17MM 0.070/ z 12 240 E17MMW 0.070/ E17MMWS 0.070/ c 24 / a 24 240 E17MXM 0.070/ c 24 / a 24 240 E17MEM 0.070/ 14

eferences Zelio ime - timing relays Industrial single or multifunction relays, solid state output, width 22.5 mm/0.89 in. Solid state output v Multifunction or single function v Multivoltage v Screw terminals v ransparent, hinged and sealable fl ap on front panel eferences Single function iming ranges Functions Voltages eference Weight V kg/lb 0.1 s 10 s A z 24 240 V E9A11MW 0.110/ z 24 240 V E9A11MW7 0.110/ PF121100A 0.3 s 30 s A z 24 240 V E9A31MW 0.110/ z 24 240 V E9A31MW7 0.110/ 3 s 300 s A z 24 240 V E9A21MW 0.110/ z 24 240 V E9A21MW7 0.110/ E9pAp1MW 40 s 60 min A z 24 240 V E9A51MW 0.110/ PF105869 z 24 240 V E9A51MW7 0.110/ Multifunction 0.1 s 0.3 s 30 s A z 24 240 V E9MS21MW 0.110/ E9MS21MW H, D, Di a 24 240 V 15

eferences Zelio time - timing relays Industrial single, dual or multifunction relays, relay output, width 22.5 mm/0.89 in. PF516208 PF516211 Output 1 /O and 2 /O contacts v Multifunction, dual function or single function v Multiple timing ranges (7 switchable ranges) v Multivoltage v 1 and 2 relay outputs: 8 A - 250 V (10 A L) v Screw or spring terminals v State indication by 1 LED v Option of supplying a load in parallel v 3-wire sensor control option E88865125 E88865155 eferences Single function iming ranges 0.6 s, 2.5 s, 20 s, 160 s Selectable interswitching time 20 ms, 40 ms, 60 ms, 80 ms, 100 ms, 120 ms, 140 ms Dual function iming ranges Multifunction Functions No. of relay outputs Voltages eference Weight V kg/lb B 1 z 24 240 E88865125 1 z 24 240 E88865135 K 2 z 24 240 E88865265 Functions No. of relay outputs Voltages eference Weight kg/lb Q 1 z 24 240 E88865175 Functions At H, Ht L, Li At, B,, H, Ht, Di, D, Ac, Bw Ad, Ah, N, O P, Pt, l, t, W No. of relay outputs a 230 / 380 E88865176 Voltages eference Weight kg/lb 2 z 24 240 E88865215 1 z 24 240 E88865115 1 z 24 240 E88865145 1 z 24 240 E88865155 1 z 24 240 E88865105 1 z 12 E88865100 1 z 12 240 E88865103 E88865503 (2) 2 of which 1 z 24 240 convertible to instantaneous z 12 z 12 240 E88865305 E88865300 E88865303 1 z 24 240 E88865185 2 z 24 240 E88865385 onnection by screw terminals. (2) onnection by spring terminals. 16

eferences (continued) Zelio time - timing relays Industrial single, dual or multifunction relays, relay output, width 22.5 mm/0.89 in. PF103444SE PF105863SE PF516221 Output 1 /O and 2 /O contacts v Multifunction, dual function or single function v Multiple timing ranges v Multivoltage v ransparent, hinged and sealable fl ap on front panel E7M11B E7MA11B E7V11B eferences (continued) iming ranges 0.05 s 300 h (10 ranges) 0.05 s 10 min (7 ranges) Functions Aw, At No. of relay outputs 1 z 24,, Ac 1 z 24,, 2 z 24,, Ak 1 z 24,, 1 z 24,, 1 z 24,, 2 z 24,, Ht, W L, Li, Lt, H, W, D, Di 1 z 24,, 1 z 24,, 1 z 24,, A 1 z 24, 2 z 24,, H 1 z 24, 2 z 24,, D 1 z 24, 2 z 24,, W 2 z 24,, Qt 2 z 24,, Qg 2 z 24,,, H, W, D, Di, Qg, Qt 2 z 24,, Voltages eference Weight V kg/lb E7M11B 0.150/ E7MA11B 0.150/ E7MA13B (symmetrical) 0.150/ E7MV11B 0.150/ E7A11B 0.150/ E7M11B (low level contact) E7L13B (low level contact) 0.150/ 0.150/ E7PM11B 0.150/ E7V11B 0.150/ E7ML11B 0.150/ E7L11B 0.150/ E7P13B 0.150/ E7PE11B 0.150/ E7PP13B 0.150/ E7L11B 0.150/ E7P13B 0.150/ E7PD13B 0.150/ E7YA12B 0.150/ E7Y12B 0.150/ E7MY13B 0.150/ 2 z 24 240 E7MY13MW 0.150/ K 1 z 24 240 E7B11MW 0.150/ 2 z 24 240 E7B13MW 0.150/ 17

eferences Zelio ime - timing relays Industrial single function relays, optimum, relay output, width 22.5 mm/0.89 in. PF105867SE v Single function v Single timing range v Output 1 /O contact v ransparent, hinged and sealable fl ap on front panel E8Apppppp eferences iming ranges Functions Voltages nit Weight reference V kg/lb 0.05 s 0.5 s K z 24, He z 24, 0.1 s 3 s A z 24, 0.1 s 10 s A z 24, E8B51BQ 0.110/ E8P01BQ 0.110/ E8A61BQ 0.110/ E8A11BQ 0.110/ z 24 E8A11BQ 0.110/ E8A11FQ 0.110/ D z 24, K z 24, H z 24, Qc z 24, E8L11BQ 0.110/ E8B11BQ 0.110/ E8PE11BQ 0.110/ E8YG11BQ 0.110/ W z 24 E8PD11BQ 0.110/ E8PD11FQ 0.110/ 0.3 s 30 s A z 24, E8A31BQ 0.110/ z 24 E8A31BQ 0.110/ E8A31FQ 0.110/ H z 24, K z 24, Qc z 24, E8PE31BQ 0.110/ E8B31BQ 0.110/ E8YG31BQ 0.110/ Qe z 24 E8YA32BQ 0.110/ E8YA32FQ 0.110/ a 380 415 E8YA32QQ 0.110/ W z 24 E8PD31BQ 0.110/ E8PD31FQ 0.110/ 3 s 300 s A z 24, E8A21BQ 0.110/ z 24 E8A21BQ 0.110/ E8A21FQ 0.110/ H z 24, Qc z 24, E8PE21BQ 0.110/ E8YG21BQ 0.110/ W z 24 E8PD21BQ 0.110/ E8PD21FQ 0.110/ 20 s 30 min A z 24, E8A41BQ 0.110/ E8A41FQ 0.110/ hese products are sold in packs of 10 18

eferences Zelio ime - timing relays niversal plug-in relays, 11-pin, relay output, width 35 mm/1.38 in. Output 2 /O contacts v Multifunction, dual function or single function v Multiple timing ranges (7 switchable ranges) v Multivoltage v 2 relay output: 8 A - 250 V (10 A L) v Plug-in v State indication by 1 LED v Option of supplying a load in parallel v 3-wire sensor control option eferences Single function iming Functions No. of relay Voltages eference Weight ranges outputs V kg/lb 2 z 24 240 E88867435 0.080/ PF516212 E88867415 Dual function At Li, L 2 z 24 240 E88867415 0.080/ 2 z 24 240 E88867455 0.080/ PF516213 E88867305 Multifunction At, B,, H, Ht, Di, D, Ac, Bw 2 of which 1 instantaneous z 24 240 E88867305 0.080/ z 12 E88867300 0.080/ z 12 240 E88867303 0.080/ PF516214 E88867300 Sockets for 11-pin relays ontact terminal arrangement For use with relays onnection nit reference Weight kg/lb Mixed (2) E88867ppp onnector XZE2M114 0.054/ 0.119 hese products are sold in packs of 10 (2) he inputs are mixed with the relay's supply, with the outputs being located on the opposite side of the socket. 19

eferences Zelio ime - timing relays niversal plug-in relays, 8-pin, relay output, width 35 mm/1.38 in. PF516215 Output 1 /O or 2 /O contacts v Multifunction, dual function or single function v Multiple timing ranges (7 switchable ranges) v Multivoltage v 1 or 2 relay outputs: 8 A - 250 V (10 A L) v Plug-in v State indication by 1 LED v Option of supplying a load in parallel v 3-wire sensor control option eferences Single function iming Functions No. of relay Voltages eference Weight ranges outputs V kg/lb 10 s, A 2 z 24 240 E88867215 0.080/ 1 z 24 240 E88867135 0.080/ PF516216 E88867215 Dual function Li, L 1 z 24 240 E88867155 0.080/ Multifunction PF516217 E88867155 At, B,, H, Ht, Di, D, Ac, Bw 1 z 24 240 E88867105 0.080/ z 12 E88867100 0.080/ z 12 240 E88867103 0.080/ E88867105 Sockets for 8-pin relays ontact For use with relays terminal arrangement Mixed (2) E888671pp, E888672pp nit reference Weight kg/lb Z2M 0.054/ 0.119 hese products are sold in packs of 10 (2) he inputs are mixed with the relay's supply, with the outputs being located on the opposite side of the socket. 20

eferences Zelio ime - timing relays Miniature plug-in relays, relay output PF516218 Output, 2 /O and 4 /O contacts v Miniature and plug-in (21 x 27 mm/0.827 x 1.062 in.) v Single function: function A = delay on energization v ated current a 5 A v 7 timing ranges (0.1 s to ) v Multivoltage v Excellent immunity to interference v Power on and relay energized indication by 2 LEDs EXL2Mpp eferences Single function iming ranges 0.1 s 1 s 0.1 min 1 min 0.1 h 1 h 10 h (7 switchable ranges) Functions No. of relay outputs Voltages eference Weight V kg/lb A 2 c 12 EXL2MJD 0.050/ 0.110 c 24 EXL2MBD 0.050/ 0.110 a 24 (50/60 Hz) EXL2MB7 0.050/ 0.110 a 120 (50/60 Hz) EXL2MF7 0.050/ 0.110 a 230 (50/60 Hz) EXL2MP7 0.050/ 0.110 4 c 12 EXL4MJD 0.050/ 0.110 c 24 a 24 (50/60 Hz) EXL4MBD 0.050/ 0.110 EXL4MB7 0.050/ 0.110 a 120 (50/60 Hz) EXL4MF7 0.050/ 0.110 a 230 (50/60 Hz) EXL4MP7 0.050/ 0.110 PF516219 Sockets for relays ontact terminal arrangement Mixed (3) For use with relays onnection nit reference (2) EXL2Mpp, EXL4Mpp Screw clamp XZE2M114 (5) Weight kg/lb 0.048/ 0.106 EXL4Mpp EXL2Mpp, EXL4Mpp onnector XZE2M114M (6) 0.056/ 0.123 Separate (4) EXL2Mpp onnector XZES108M 0.070/ EXL4Mpp onnector XZE2S114M 0.058/ 0.128 For c 48 V supply, additional resistor 560 2 W / c 24 V. For a 48 V, additional resistor 390 4 W / a 24 V. (2) hese products are sold in lots of 10. (3) he inputs are mixed with the relay's supply, with the outputs being located on the opposite side of the socket. (4) he inputs and outputs are separated from the relay supply. (5) hermal current Ith: 10 A. (6) hermal current Ith: 12 A. 21

eferences Zelio ime - timing relays Analog, electronic relays, relay output, 48 x 48 PF110452 PF110451 DF523398 Output 2 /O contacts v ime unit selector knob v Multifunction, single function or dual function v Multirange v Multivoltage v 2 relay outputs, 5 A v Panel-mounted or plug-in v LED indication E48AM12MW E48AMH13MW eferences 8-pin relay iming ranges Function No. of relay outputs 1.2 s, 3 s, 12 s, 30 s, 120 s, 300 s, 12 min, 30 min, 120 min, 300 min, 12 h, 30 h, 120 h, 300 h 11-pin relay 1.2 s, 3 s, 12 s, 30 s, 120 s, 300 s, 12 min, 30 min, 120 min, 300 min, 12 h, 30 h, 120 h, 300 h Sockets Description Voltages eference Weight V kg/lb A 1 z 24 240 E48AM12MW 0.140/ 0.309 A1, A2, H1, H2 L, Li B,, Di IP 20 sockets with connection by connector and mixed contact terminals Number of pins 2 of which 1 z 24 240 E48AMH13MW 0.140/ instantaneous 0.309 2 z 24 240 E48AV12MW 0.140/ 0.309 2 z 24 240 E48AML12MW 0.140/ 0.309 For use with relays 8 E48AM12MW, E48AMH13MW 11 E48AV12MW, E48AML12MW Sold in lots of nit reference Weight kg/lb 10 Z2M 0.054/ 0.119 10 Z3M 0.054/ 0.119 109804 Z3M IP20 socket with screw terminal connections on rear face 11 E48AV12MW, E48AML12MW 1 E48ASO11A onnectors and protective cover IP20 solder connectors 8 E48AM12MW, E48AMH13MW 1 E48ASO8SOLD E48ASO11A 109803 109805 11 E48AV12MW, E48AML12MW 1 E48ASO11SOLD E8ASO8SOLD E48ASO11SOLD Setting protection cover E48AM12MW, E48AV12MW, E48AML12MW, E48AMH13MW 1 E48ASEOV 109806 109807 Protective cover IP64 E48AM12MW, E48AV12MW, E48AML12MW, E48AMH13MW 1 E48AIPOV E48ASEOV E48AIPOV he inputs are mixed with the relay s supply terminals, with the outputs being located on the opposite side of the socket 22

eferences Zelio ime - timing relays Panel-mounted universal, plug-in relays, relay output PF112150SE Output 1 /O or 2 /O contacts v LD display v Multifunction or single function v Multirange v Multivoltage v 1 8A relay or 2 relay outputs: 5 A (E8885740p), 8 A (E8885730p) v eset function on front panel (E8885730p) v Memory in the event of mains power failure (E 88 857 30p) v Locking of access to programming (E8885710p and E8885700p) v pcount or downcount mode v Internal supply by lithium battery (10 years at 20 ) eferences 8-pin relay iming ranges 99.99 s, 999.9 s, 9999 s, 99 min 59 s, 99.99 min, 999.9 min, 9999 min, 99 h 59 min, 99.99 h, 999.9 h, 9999 h Functions No. of relay Voltages eference Weight outputs V kg/lb A 2 z 24 E88857409 0.140/ 0.309 a 110 E88857406 0.140/ 0.309 a 220 240 E88857400 0.140/ 0.309 B,, D, Di, H 1 c 12 and z 24 48 z 24 and z 24 and z 48 z 24 V and a 110, (50/60 Hz) z 24 and a 24 240, (50/60 Hz) E88857003 0.100/ 0.220 E88857005 0.100/ 0.220 E88857604 0.100/ 0.220 E88857607 0.100/ 0.220 E88857601 0.100/ 0.220 11-pin relay PF516220 E8885740p 99.99 s, 999.9 s, 9999 s, 99 min 59 s, 99.99 min, 999.9 min, 9999 min, 99 h 59 min, 99.99 h, 999.9 h, 9999 h B,, D, Di, H 1 c 12 and z 24 48 z 24 and z 24 and z 48 z 24 V and a 110 (50/60 Hz) z 24 and a 24 240 (50/60 Hz) E88857103 0.100/ 0.220 E88857105 0.100/ 0.220 E88857704 0.100/ 0.220 E88857707 0.100/ 0.220 E88857701 0.100/ 0.220 E8885760p A1, A2, AM, AMt 2 of which 1 instantaneous c 12 V and z 24 and a 110 z 24 V and a 220 240 E88857302 0.140/ 0.309 E88857307 0.140/ 0.309 E88857301 0.140/ 0.309 Sockets for relays Number For use with relays of pins nit reference Weight kg/lb 8-pin connector E8885740p, E8885700p, E8885760p Z2M 0.054/ 0.119 11-pin E8885710p, E8885730p, E8885770p Z3M 0.054/ 0.119 hese products are sold in packs of 10. 23