Woven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out.

Similar documents
Testing. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified.

Securifor Polyester Coated Welded Mesh Panels

RR-F-191/1D 14 May SUPERCEDING RR-F-191/1C July 22, 1981 FEDERAL SPECIFICATION SHEET

Standard Specification for Copper-Clad Steel Wire for Electronic Application 1

Procedure for Testing Direct Tension Indicators (DTI) Assemblies

PART MATERIALS. Section Fencing Materials. Description

Barofor Round System (polyester coated) Panels, Posts, Accessories

Standard Specification for Steel Transmission Tower Bolts, Zinc-Coated and Bare 1

DRAFT UGANDA STANDARD

Standard Specification for Steel Transmission Tower Bolts, Zinc-Coated and Bare 1

SECTION METAL FABRICATIONS

Standard Specification for High-Strength Bolts for Structural Steel Joints [Metric] 1

Standard Specification for Fence Fittings 1

Use the arrow keys to easily navigate through the course.

APPENDIX FENCE GENERAL NOTES

Fluid Sealing Association

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

A. Extent of structural precast concrete work is shown on drawings and in schedules.

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

ICC-ES Evaluation Report

2016 AASHTO BRIDGE COMMITTEE AGENDA ITEM: 24 (REVISION 1) SUBJECT: LRFD Bridge Design Specifications: Section 6, Various Articles (2)

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

Government Recognized Export House OHSAS 18001:2007 ISO 14001:2004 PED Approved Company.

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

Contents. Grade 2, 5, 8 Hex Bolts 4. Heavy Hex Head Structural Bolts 6. A325 and A490 Tension Control Bolts (TC) 13. Nuts 22.

Designation: F

SECTION TRAFFIC SIGNAGE

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

JIS G3465 Seamless Steel Tubes for Drilling

Evaluation of In-Pavement Light Fixture Designs and Performance

VERIFYING THE ACCURACY OF WIRE CLOTH SIEVES

Specifications - Common Nails Diamond point, Flat head, round smooth shank, Bright, HDG, EG or cement coated (resin or vinyl) finish

1.0 DESCRIPTION. This specification covers steel snowplow blades with tungsten carbide inserts.

Section 808. FENCING

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

ANSI/BHMA A Revision of ANSI/BHMA A

ALLOY STEEL SOCKET SET SCREWS 1

SECTION CHAIN LINK FENCING AND GATES

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

ESR-1271* Reissued September 1, 2013 This report is subject to renewal July 1, 2015.

Standard Specification for Quenched and Tempered Steel Bolts and Studs 1

Certificate of Accreditation

Effect of Washer Placement on Performance of Direct Tension Indicators

FEDERAL SPECIFICATION SHEET. FENCING, WIRE AND POST METAL (CHAIN-LINK FENCE FAfiRIC) (DETAIL SPECIFICATION)

SECTION CHAIN LINK FENCE GALVANZED CHAIN LINK FABRIC ON GALVANIZED FRAMEWORK [Provided by Master Halco]

NORMATIVE REFERENCES

Project: # Solano Community College District

SSPC-PA 2 Procedure for Determining Conformance to Dry Coating Thickness Requirements

Standard Test Procedures Manual

Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Used as Electrical Conductors 1

NORMATIVE REFERENCES

Letter of Transmittal/Submittal

TerraLink. Twisted Wire Mesh Gabions & Mattresses Welded Wire Mesh Gabions. Data Sheet s Index. TerraLink Products

Standard Specification for Electric-Resistance-Welded Metallic-Coated Carbon Steel Mechanical Tubing 1

HEADLINE BUILDING MATERIALS

Use the arrow keys to easily navigate through the course.

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

ICC-ES Evaluation Report

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

REPORT HOLDER: SFS INTEC 1045 SPRING STREET WYOMISSING, PENNSYLVANIA EVALUATION SUBJECT:

HEXAGONAL DOUBBLE TWISTED GABION & ROCK FALL MATRESSES

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

A Full Line of Pipe Products for Any Application

Standard Specification for Carbon and Alloy Steel Nuts [Metric] 1

calculated with factor of safety of 2.5 for bending stress, 3.0 for shear stresses and deflection limitation of L/180.

GENERAL ISOMETRIC LAYOUT

PURE GP. Adhesives GENERAL INFORMATION SECTION CONTENTS. Epoxy Injection Adhesive Anchoring System

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

Accredited Laboratory

1 WEAVE Plain. YARN WRAP EC9 430tex ETG 11.6 (tex) WEFT EC9 430tex ETG 11.6

For crossing under a railroad, contact the specific railroad company's engineering department.

6o ft (18.3 m) Southwest Windpower, Inc West Route 66 Flagstaff, Arizona USA Phone: Fax:

SSPC-PA 2 Procedure for Determining Conformance to Dry Coating Thickness Requirements

ODOT ITB Group 4 Item 33 Qty. 1

*Revised September 1, 2003

CERTIFICATE OF ACCREDITATION

Ordering example: WSK-600 / B x H x L = 155 mm. M8 hexagon head screw, fixed by a locknut. Threaded bolt

SECTION (10670) - WIRE CLOSET AND UTILITY SHELVING

Ranch, Home and Garden

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Revised September 2003

Use the arrow keys to easily navigate through the course.

Steel wire for general fencing purposes

SECTION BULLET- RESISTANT DOORS

MATERIAL SPECIFICATION FOR GABION BASKETS AND MATS

SECTION HOLLOW METAL DOORS AND FRAMES

CERTIFICATE OF ACCREDITATION

SECTION ELECTRICAL IDENTIFICATION

DXe SUBSEA WELLHEAD CONNECTORS

Section COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT:

FEDERAL SPECIFICATION SHEET FENCING, WIRE AND POST, METAL (CHAIN-LINK FENCE ACCESSORIES) (DETAIL SPECIFICATION)

Hex Cap Screws Coarse & Fine Thread

Requirements for manufacture of anchors

MILITARY SPECIFICATION SHEET SCREW, CAP, SOCKET HEAD- HEXAGON, CORROSION RESISTANT STEEL, UNC-3A

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Edgewise compressive strength of corrugated fiberboard using the Morris method (short column test)

Indian Standard SPECIFICATION FOR USE IN FOUNDRIES. 1.1 This standard covers the requirements for chaplets for use in foundries.

A guide to BONNOX Game Fencing

Transcription:

Woven Steel Wire Fence Type-47 Under the state specification 710.02 for fencing, ASTM A 116 is called out. Go to the steel and fencing certification manual for more information about the basic properties of steel. Dimension Requirements Dimensions should be verified to assure the delivered product meets what you ordered. The state mandates that the woven wire fence fabric shall be design number 1047-6-9. The sizes and constructions for fence fabric under A 116 is required to meet the following requirements. Design Numbers for Woven Wire Fence Fabric Fence Height Size, Steel Wire Gage Design Numbers Number of Horizontal Wires Nominal (Design), in Specified (Actual), in. (cm) Spacing of Stay Wires, in. (cm) Intermediate Line and Stay Wires Top and Bottom Wires No. 9 1047-6-9 10 47 46.5 (118) 6 (15) 9 9 An example of a sample woven wire would be design number 1047-6-9. Which has a wire gage size of 9 with 10 horizontal wires and a fence height of 46.5 inches. 1

The woven wires shall be uniformly wrapped joints and all stay wires shall be spaced properly. The permissible variation of the wire should be within ± 0.005 inches. The line and stay wire spacing should not vary more than 3/8 inch from the nominal dimensions. Due to the mechanics of manufacture, a certain amount of out-of-roundness is expected on the stay wires of the finished fence fabrics. The length of fence fabric in a roll is required to be 330 ft. The length of the fence fabric in a roll should be the specified length within a tolerance of 3 %. Mechanical Requirements Along with Dimensional requirements another key issue is the mechanical properties of the material. Listed below is the information that can be found in the applicable specifications for steel wire. The breaking strength of line wires should meet these requirements. Breaking Strength of Line Wires Note 1 - There is no breaking strength requirement for stay wires. Size, Steel Wire Gage Tensile Strength Grade, ksi Nominal Diameter in. (mm) Minimum Breaking Strength Line Wires Only lbf (N) 9 10 10 ½ 11 14 14 ½ 14 ½ 175 (175) 0.148 (3.77) 0.135 (3.43) 0.128 (3.25) 0.120 (3.05) 0.080 (2.03) 1030 (4590) 860 (3820) 1610 (7160) 685 (3050) 460 (2050) 960 (4280) 1345 (5990) 630 (2800) 270 (1210) 565 (2520) 2

An example of a breaking strength in line wires would be size # 9. This wire has a nominal diameter of 0.148 inches, a tensile strength of 60 ksi and a minimum breaking strength of 1030 lbf. Test at least four specimens, with one specimen from the top or bottom line wires, and the other three specimens from the intermediate line wires. There is no breaking test for the stay wires. The specified height of the fence fabric is based on the sum of the line wire spacings shown in the following figure. Inspection shall be done at the project site. Random samples shall be obtained from material delivered to the project site or at other locations designated by the Laboratory. The purchaser shall be furnished written certification that the woven steel wire was manufactured, sampled, tested, and inspected in accordance with A 116 and has been found to meet the requirements. The purchase order is required to report test results for the material. 3

Coating Thickness The steel wire is to be coated by either Type A, Z, or ZA coating material. The steel wire is to be coated before fabrication, to the coating class specified in the order and meeting the following requirements. Minimum Weight of Metallic Coating Minimum Weight of Coating, oz/ft 2 (g/m 2 ) Size, Steel Wire Gage Diameter in. (mm) Type A Type Z Class 1 Type Z Class 3 Type ZA Class 20 Type ZA Class 40 TYPE ZA Class 80 No. 9 No. 10 No. 10 ½ No. 11 No. No. 14 No. 14 ½ 0.148 (3.76) 0.135 (3.43) 0.128 (3.25) 0.120 (3.05) 0.080 (2.03) 0.32 (98) 0.28 (85) 0.25 (76) 0.90 (275) 0.70 (214) 0.70 (214) Here is an example of the minimum weight of metallic coating for a size # 9 woven wire. The diameter of the wire is 0.148 inches and the minimum weight for a Type A wire is 0.40 oz/ft 2. For Type Z wire there are two different classes, Class 1 and Class 3. The minimum weight for Class 1 is 0.35 oz/ft 2 and the minimum weight for Class 3 is 0.90 oz/ft 2. For Type ZA wire there are three different classes, Class 20, Class 40 and Class 80. The minimum weight for Class 20 is 0.20 oz/ft 2, for Class 40 the minimum weight is 0.40 oz/ft 2 and for Class 80 the minimum weight is 0.80 oz/ft 2. 4

Sample Certification This sample certification for woven wire is not correct and here are some of the reasons. The manufacturer didn t specify which diameter they used to figure out the breaking strength of the wires. For woven wire they have the diameter as 0.148" ±.005", does that mean 0.143", 0.148" or 0.153". The diameter of the wire will make a difference on how much the breaking strength will be on the wire. The calculations of the breaking strength for the 0.143" diameter would be 963 lbf, for the 0.148" diameter the breaking strength would be 1,032 lbf and for the 0.153" diameter the breaking strength would be 1,103 lbf. As you can see, if they would have use the 0.143" diameter they would have failed the test because the minimum breaking strength for a size 9 woven wire is 1,030 lbf. The wires 0.148" and 0.153"would have been okay because their breaking strength had pass the minimum possible. They should have specific the tensile strength because 60,000 PSI and 75,000 PSI will make a big difference in the calculations of the breaking strength. This certification should have specified the breaking strength of the wire they tested. 5