Upright Microscope. Upright Microscope ECLIPSE Ci-E/Ci-L

Similar documents
Upright Microscope. Upright Microscope ECLIPSE Ci-E/Ci-L

Biological Microscope. Biological Microscope ECLIPSE E100

Inverted Research Microscope. Inverted Research Microscope ECLIPSE Ts2R

FPD/LSI Inspection Microscopes

EXC500p-- PATHOLOGY MICROSCOPE. EXC500hd -- HD DIGITAL PATHOLOGY MICROSCOPE. EXC500r -- RESEARCH MICROSCOPE EXC500-LABORATORY SCOPE

Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series

Specifications Optical system Main body Focusing. Dimensional Diagram. Fixed Stage Microscope for Electrophysiological Research

Wafer Loaders for IC Inspection Microscopes NWL200 Series. Wafer Loaders for IC Inspection Microscopes

Digital Microscope ShuttlePix P-400R. Digital Microscope. A new era of microscopy: Shuttle style.

Super Resolution Microscope N-SIM E. Super Resolution Microscope

Fixed Stage Microscope for Electrophysiological Research. Fixed Stage Microscope for Electrophysiological Research

Confocal Microscope. Confocal Microscope C2

Ryf AG Bettlachstrasse Grenchen tel fax Industrial Microscopes

VMZ-K3040 CONFOCAL. Confocal Imaging & Metrology. CNC Video Measuring System. Specifications. Dimensional Diagram

Fixed Stage Microscope for Electrophysiological Research

Confocal Microscope. Confocal Microscope C2

Confocal NEXIV VMZ-K Series. CNC Video Measuring System CONFOCAL NEXIV. VMZ-K Series

Complete support to all your needs

Microscope ECLIPSE 80i Instructions <Reference>

Confocal NEXIV VMZ-K Series. CNC Video Measuring System CONFOCAL NEXIV. VMZ-K Series

Cell culture, observation and image capture three functions incorporated into one single long-term time-lapse imaging system

Microscope objectives

CNC Video Measuring System NEXIV VMZ-K series. CNC Video Measuring System. Confocal Model

Nikon E800 Operating Instructions.

Polarizing Microscopes

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

STEINDORFF NYMC Polarizing Microscope

NeoScope. Simple Operation to 40,000. Table Top SEM. Serving Advanced Technology

User Manual. Trinocular Metallurgical Microscope. MicroscopeNet.com

DIGITAL CAMERA SYSTEM FOR MICROSCOPY

BA310POL ADVANCED POLARIZATION MICROSCOPE

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING

Sunny Instruments. RX50 Biological Microscope

Instruction Manual T Binocular Acromat Research Scope T Trinocular Acromat Research Scope

Manual for BMS E1 eplan series, compound microscope

DIGITAL CAMERA SYSTEM FOR MICROSCOPY

Objectives for biological microscopes. Objectives for biological microscopes

Imaging Introduction. September 24, 2010

EPIFLUORESCENCE &/OR BRIGHTFIELD MICROSCOPY

Industrial Microscope ECLIPSE LV100DA Instructions

Characterization Microscope Nikon LV150

CX-PCD INSTRUCTIONS PHASE CONTRAST TURRET CONDENSER

Image Analysis Software. Advanced Solutions for your Imaging World

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

TABLE OF CONTENTS. Safety notes i. Care and Maintenance. ii. 1. Components Illustration Installation of Components.. 4

Polarizing Microscope BX51-P

ML7520 ML7530 DIOPTER ADJUSTMENT RING BINOCULAR BODY, INCLINED 30. (a) Field Iris Control Lever. (c) Filter Slots EYEPIECES, KHW10X

CNC Video Measuring System. CNC Video Measuring System NEXIV VMZ-R

Nikon E800 Operating Instructions.

Stereoscopic Zoom Microscope. Stereoscopic Zoom Microscope SMZ1500

OPELCO OPtical ELements COrporation LB Objective Series for Biological Use

DOCUMENT CAMERA. TT-02s. Teacher s Tool

STEINDORFF METALLURGICAL MICROSCOPE. NYMCS-620 Instruction Manual

Using the Nikon TE2000 Inverted Microscope

Introduction. Laboratory Equipment & Supplies. Model 1333PHi Shown (Phase Contrast) (2) Eyepieces (Eyecups installed) Diopter Adjustment Mechanism

OMM300. Inverted Metallurgical Microscope

KL Series. Fiber optic illumination for stereo microscopy

Huvitz Digital Microscope HDS-5800

The world's first microscope designed expressly for patch clamp experiments. Upright Research Microscope for Patch Clamp Experiments

A DIVISION OF FORENSIC TECHNOLOGY SEE MORE. SOLVE MORE. CLASS-LEADING COMPARISON MICROSCOPES FOR FORENSIC INVESTIGATIONS

User Manual. Trinocular Infinity Compound LED Microscope. MicroscopeNet.com

START-UP PROCEDURE 1 THE MICROSCOPE STAND 3 OBJECTIVES 5 STARTING WITH LAS (SOFTWARE) AND SETTING UP THE MICROSCOPE STAND 7

TECHNICAL SPECIFICATION SCHEDULE

Introducing the world s first automated patch clamp system!

Zeiss Axio Imager.A1 manual

Nikon E800 Microscope. Operating Instructions


Widefield-NikonEclipseTE200-ORCA Nikon Eclipse TE200 Inverted Microscope with Hamamatsu 1394 Orca-ER Cooled CCD Camera and Micromanager Software

Microscopy Training & Overview

Keyence Revolutionises Machine Vision...

LC15Dx Laser scanner High accuracy with high resolution. nikon metrology I vision beyond precision

2/4/15. Brightfield Microscopy! It s all about Magnification..! or is it?!

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Systematic Workflow via Intuitive GUI. Easy operation accomplishes your goals faster than ever.

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 1: THE LIGHT MICROSCOPE

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Nature Protocols: doi: /nprot Supplementary Figure 1. Schematic diagram of Kőhler illumination.

Leica SP8 TCS Users Manual

Operating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5.

Nikon C1si Spectral Laser Scanning Confocal Microscope. User Guide

BASICS IN BIOIMAGING AND OPTICS PLATFORM EPFL SV PTBIOP LIGHT MICROSCOPY

Nikon TE300 Eclipse Wide-Field Microscope

Nikon Ti-E Microscope Manual. Rightmire Hall Ohio State University. Director: Tony Brown Rightmire

Real-color High Sensitivity Scientific Camera

Using Optics to Optimize Your Machine Vision Application

Fein. High Sensitivity Microscope Camera with Advanced Software 3DCxM20-20 Megapixels

Nikon Eclipse Ti A1-A Confocal Operating Manual. Start-up. Microscope

A BRIEF INTRODUCTION TO MICROSCOPY The two key properties of a microscope that allow you to see microbes are resolution and magnification.

Motorized Axio Observer Start-up instructions

The fully equipped all-round compound microscope for schools, training and laboratories

SWIFT SERIES M2252DGL MICROSCOPE

OM FL400. Reflected Light Fluorescence Microscope. Instruction Manual. Please read instructions carefully before using microscope.

Systems Biology. Optical Train, Köhler Illumination


Epi-LED FL Fluorescence Microscope Instruction Manual

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

TEKSCOPE MICROSCOPE. Models N2 Series USER S MANUAL

Practical Light Microscopy

Thermo Scientific SPECTRONIC 200 Education

Transcription:

Upright Microscope Upright Microscope ECLIPSE Ci-E/Ci-L

Feel the evolution Compact research microscope with superior optical performance Nikon has drawn on its proven optics and mechanical design technologies to develop the compact and high-performance ECLIPSE Ci series research microscope. High-quality objective lenses and a dedicated epi-fluorescence attachment provide bright and high contrast fluorescence images. Image capture of specimens is easy and efficient when the microscope is configured with Nikon Digital Sight series cameras. In addition, a newly developed high luminescent LED illumination and accessories that allow for a comfortable posture during observation and imaging are also available. With its high-optical performance and advanced easy control, the ECLIPSE Ci series supports the research of a broad range of user applications. High-intensity, uniform LED illumination (Eco-illumination) Compact dedicated fluorescence unit Reliable high-performance objective lens Observation and image capture with comfortable posture Motorized magnification switching by the push of a button (Ci-E) Simple image capturing by the push of a button on the microscope Enables a wide variety of observations Configuration of Ci-L with epi-fluorescence attachment and DS-Fi1c camera 2

High quality images powered by Nikon s reputed optical technologies Nikon's well-reputed optical technologies enable the capture of sharp and high quality images in a wide variety of techniques, including brightfield and epi-fluorescence observations. The epi-fluorescence attachment of the ECLIPSE Ci series allows weakly fluorescing specimens to be captured with great clarity and brightness. Epi-fluorescence attachment The dedicated noise terminator for the Ci series is utilized in the compact epi-fluorescence attachment and this allows bright, high-contrast and high signal to noise (S/N) ratio fluorescence image capturing. Two epi-fluorescence attachments are available, CI-FL (four filter cubes mountable) and D-FL (six filter cubes mountable). The name and position of the filter cubes are displayed in front of the attachment with phosphorescent labels for easy identification in darkened rooms. The filters or dichroic mirrors in the filter cubes can be easily replaced to create a more specific combination Camera Fluorescence filter cube Black plate Light source Stray light Black plate Lens Noise terminator mechanism High-optical performance objective lenses CFI Plan Apochromat Lambda series With remarkably high NA, greatly improved transmission in the long wavelength range thanks to Nikon proprietary Nano Crystal Coat, and chromatic aberration correction over wide wavelength range, these objectives are ideally suited not only to brightfield observations but also to fluorescent observations. Bright images can be captured even with a weak excitation light, thereby reducing damage to the specimen. Nano Crystal Coat CFI Plan Fluor series Featuring an extra-high transmission rate, especially in the ultraviolet wavelength, combined with flatness of field, this series is perfect for fluorescence observation and imaging. These objectives can function as multi-purpose objectives for brightfield, fluorescence and simple/sensitive color polarizing observations. This anti-reflective coating with nanometer-size particles is based on semiconductor manufacturing technology and is also used for Nikon camera lenses. The coarse structure with particles arranged in a spongy construction with uniform spaces between them enables extremely low refractive indices. Incident light Reflected light Lens Conventional multi-layer coating Incident light Reflected light Lens Nano Crystal Coat 3

Unparalleled basic performance Nikon has created a highly advanced basic performance with the ECLIPSE Ci-E/Ci-L including bright illumination, various accessories that enable comfortable observation posture, and convenient motorized operations. Eco-illumination By combining a collimator lens, fly-eye optics and LED illumination, bright and uniform images up to the periphery can be obtained. The LED is a low power consumption unit that reduces lamp replacement frequency thanks to its long-life, and provides the same color temperature in every magnification. (Patent pending) LED Collimator lens Fly-eye optics Viewed with Eco-illumination Viewed without Eco-illumination Ci-E (Motorized model) *These images are captured without using the shading compensation to emphasize the vignetting. Ergonomic design Various accessories that allow observation and image capturing with comfortable posture. Ergonomic binocular tube Eyepiece angle (10-30 ) and extension (up to 40mm) are adjustable. A camera can be mounted via the DSC port. Eyelevel riser Eye-point height can be raised in 25mm increments to suit your normal posture. Stage with height-adjustable handle Smooth stage movement is achievable with a comfortable hand position. Lower stage positioning Stage height can be lowered 20mm from the standard position using the nosepiece spacer for easy specimen change with comfortable posture. Motorized model Ci-E Equipped with motorized magnification switching and automatic intensity reproduction, it is ideally suited to applications that require frequent magnification switching. Nosepiece rotating buttons The nosepiece can be rotated with one-touch button control. In addition, your two favorite magnifications can be registered*, and one press of the button alternates between these two objective lenses. * Using the remote control pad. 4 Remote control pad By programming specific buttons to correspond to specific objective lenses, magnification can be easily changed with a one touch button. Auto light intensity reproduction The user-defined light intensity for each objective lens is automatically memorized and replicated when the objective is used again, eliminating the manual readjustment.

Enhanced operability for digital imaging The ECLIPSE Ci series microscope, imaging system Digital Sight series and imaging software NIS-Elements support smart image capturing with enhanced function. Image capture button Imaging with the Digital Sight series cameras is possible with the one touch button located on the microscope base. Camera control unit Digital Sight DS-L3 The stand-alone controller with a large-size display monitor enables image capture without a computer. The touch panel allows simple setting and operation of a Digital Sight camera by simply choosing the observation technique using scene mode icons. Simple measurement functions, such as distance measurement between two points, are available. In addition, objective lens switching and Ci-E condenser setting are also possible. A network function enables image sharing of live images with multiple remote PCs during observation. * DS-L3 cannot be connected to DS-Ri2 and DS-Qi2 cameras. Imaging software NIS-Elements By connecting the Ci-E/Ci-L with a PC, capturing, processing, measuring, analyzing and management of images are possible using the dedicated imaging software NIS-Elements. (With the Ci-L, the DS-L3 or DS-U3 control unit is required.) Live image comparison Merge channels Enables easy image comparison between a captured image and a live image. Live observation side by side with a paused live image is also available. Multiple single channel images can be merged together to create an overlay of full depth separately scalable images. Object counting This measures the number or area of objects extracted from images and is achieved by the creation of a binary layer through thresholding, using RGB/HIS or intensity values. Digital Sight series C-mount camera heads Digital Sight series F-mount microscope cameras High-definition colorcamera head DS-Fi2 High-definition cooled color camera head DS-Fi1c Microscope Camera DS-Ri2 5.0-megapixel CCD Up to 2,560 x 1,920 pixels High-speed movie display up to 21 fps is possible. 5.0-megapixel CCD Up to 2,560 x 1,920 pixels Equipped with a Peltier cooling device that retains the CCD at an ambient temperature of -20C to reduce heat noise, it is ideally suited for capturing fluorescent images. Monochrome Microscope Camera DS-Qi2 16.25-megapixels Up to 4908 x 3264 pixels 16.25-megapixels Up to 4908 x 3264 pixels Equipped with digital SLR camera FXformat CMOS sensor. Provides superior color reproduction and fast frame rates. Equipped with FX-format CMOS sensor. Enables high-sensitivity, low-noise images. 5

Accessories for various observations The ECLIPSE Ci-L/Ci-E uses a high-intensity Eco-illumination that provides sufficient light intensity even for phase contrast and simple polarizing observation. The wide variety of accessories enables the user to conduct various techniques including epi-fluorescence observation. Phase contrast High contrast images with neutral background coloration regardless of the magnification range can be acquired. This observation technique is suitable for observation of the unstained structure. Darkfield Enables clear observation of blood or the minute structure of flagella. Dry- and oil-type condensers are available. The expander lens is used to obtain illumination with greater brightness. Ci-L with phase contrast accessories Simple polarizing This is ideal for observing bi-refringent samples such as collagen, amyloids and crystals. *Two types of analyzer are available: intermediate tube type and nosepiece slider type. Sensitive color polarizing This enables the identification of uric acid crystals forming inside an organism by changing the interference color and is ideal for gout and pseudo-gout tests. *Two types of analyzer are available: intermediate tube type and nosepiece slider type. New advanced research microscopes ECLIPSE Ni series The ECLIPSE Ni series is the flagship of Nikon s upright research microscopes. They provide high optical performance and high expandability with various motorized accessories utilizing stratum structure. Manual model Ni-U with advanced basic performance Fully motorized model Ni-E with motorized focusing and auto observation technique switching. Fly-eye optics enable the capture of bright and uniform illuminated digital images. The noise terminator mechanism equipped in the epi-fluorescence system enables high S/N ratio image. Ni-U with motorized epi-fluorescence attachment and Digital Sight series cameras 6

System Diagram DS-F2.5 F-Mount Adapter 2.5x C-HGFIE-C HG Controller (for control of the motorized model) 7

Specifications Main body Tubes Nosepieces Stages Condensers (NA) Optical system Illumination Controls Eyepieces (F.O.V. mm) Focusing F.O.V. 22 mm (Eyepiece/Port) F.O.V. 25 mm (Eyepiece/Port) Motorized Manual Observation methods* Epi-fluorescence attachment Epi-fluorescence light source CFI60 Infinity Optical System Ci-E High luminescent White LED Illuminator (Eco-illumination) Automatic intensity reproduction function Image capture button Nosepiece rotating buttons, Remote control pad CFI 10 (22) CFI 10 M photomask (22) CFI 12.5 (16) CFI 15 (14.5) CFI UW 10 (25) CFI UW 10 M photomask (25) Coaxial Coarse/Fine focusing, Stroke: 30 mm, Coarse: 9.33 mm/rotation, Fine: 0.1 mm/rotation, Coarse motion torque adjustable, Refocusing function C-TB Binocular Tube C-TE2 Ergonomic Binocular Tube (100/0, 50/50 via optional C-TEP2 DSC Port), Inclination angle: 10-30, Extension: up to 40 mm C-TF Trinocular Tube F (100/0, 0/100) C-TT Trinocular Tube T (100/0, 20/80, 0/100) Motorized Sextuple Nosepiece with Analyzer Slot (Within main body) Switching between two objectives function Ci-L C-N6 ESD Sextuple Nosepiece ESD C-N6A Sextuple Nosepiece with Analyzer Slot Cross travel 78 (X) 54 (Y) mm, with vernier calibrations, stage handle height and torque adjustable for all stages C-HIC Double Arm Specimen Holder is available as an option for the below three stages. C-SR2S Right Handle Stage with 2S Holder C-CSR1S Right Handle Ceramic-coated Stage with 1S Holder C-CSR Right Handle Ceramic-coated Stage (C-H2L Specimen Holder 2L and C-H1L Specimen Holder 1L can be attached) CI-C-E Motorized Swing-out Condenser (0.9/0.22) Focusing stroke: 27 mm Focusing stroke: 27 mm C-C Abbe Condenser (0.9) C-C Achromat Condenser (0.8) Darkfield Condenser Oil (1.2-1.43) Darkfield Condenser Dry (0.8-0.95) C-C Phase Contrast Turret Condenser (0.9) C-C Achromat Aplanatic Condenser (1.4) C-C Slide Achromat Condenser 2-100 (0.9) C-C Achromat Swing-out Condenser 1-100 (0.8/0.12) Achromat Swing-out Condenser 2-100 (0.9/0.22) X LWD Condenser (0.65) Brightfield, Epi-fluorescence, Darkfield, Phase contrast, Simple polarizing, Sensitive color polarizing CI-FL Epi-fluorescence Attachment (4 filter cubes mountable) D-FL Epi-fluorescence Attachmennt (6 filter cubes mountable) ND4/ND8/ND16 filters, Noise Terminator mechanism C-HGFI/HGFIE HG Precentered Fiber Illuminator Intensilight (130W) Hg Lamphouse and Power Supply (100W) Xenon Lamphouse and Power Supply (75W) Power consumption 13W (Brightfield configuration) 6W (Brightfield configuration) Weight (approx.) 15.4 kg (Binocular standard set) 13.4 kg (Binocular standard set) *Observations except Brightfield require optional accessories. Dimensional Diagram Unit: mm Ci-E Ci-L Configured with Ergonomic Binocular Tube and DSC port Configured with Fluorescence Attachment and Trinocular Tube T Company names and product names appearing in this brochure are their registered trademarks or trademarks. N.B. Export of the products* in this brochure is controlled under the Japanese Foreign Exchange and Foreign Trade Law. Appropriate export procedure shall be required in case of export from Japan. *Products: Hardware and its technical information (including software) Monitor images are simulated. Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer. June 2014 2011-14 NIKON CORPORATION WARNING TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT. NIKON CORPORATION Shin-Yurakucho Bldg., 12-1, Yurakucho 1-chome, Chiyoda-ku, Tokyo 100-8331, Japan phone: +81-3-3216-2375 fax: +81-3-3216-2385 http://www.nikon.com/instruments/ NIKON INSTRUMENTS INC. 1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A. phone: +1-631-547-8500; +1-800-52-NIKON (within the U.S.A. only) fax: +1-631-547-0306 http://www.nikoninstruments.com/ NIKON INSTRUMENTS EUROPE B.V. Tripolis 100, Burgerweeshuispad 101, 1076 ER Amsterdam, The Netherlands phone: +31-20-7099-000 fax: +31-20-7099-298 http://www.nikoninstruments.eu/ NIKON INSTRUMENTS (SHANGHAI) CO., LTD. CHINA phone: +86-21-6841-2050 fax: +86-21-6841-2060 (Beijing branch) phone: +86-10-5831-2028 fax: +86-10-5831-2026 (Guangzhou branch) phone: +86-20-3882-0552 fax: +86-20-3882-0580 NIKON SINGAPORE PTE LTD SINGAPORE phone: +65-6559-3618 fax: +65-6559-3668 NIKON MALAYSIA SDN. BHD. MALAYSIA phone: +60-3-7809-3688 fax: +60-3-7809-3633 NIKON INSTRUMENTS KOREA CO., LTD. KOREA phone: +82-2-2186-8400 fax: +82-2-555-4415 NIKON CANADA INC. CANADA phone: +1-905-602-9676 fax: +1-905-602-9953 NIKON FRANCE S.A.S. FRANCE phone: +33-1-4516-45-16 fax: +33-1-4516-45-55 NIKON GMBH GERMANY phone: +49-211-941-42-20 fax: +49-211-941-43-22 NIKON INSTRUMENTS S.p.A. ITALY phone: +39-055-300-96-01 fax: +39-055-30-09-93 NIKON AG SWITZERLAND phone: +41-43-277-28-67 fax: +41-43-277-28-61 NIKON UK LTD. UNITED KINGDOM phone: +44-208-247-1717 fax: +44-208-541-4584 NIKON GMBH AUSTRIA AUSTRIA phone: +43-1-972-6111-00 fax: +43-1-972-6111-40 NIKON BELUX BELGIUM phone: +32-2-705-56-65 fax: +32-2-726-66-45 En Printed in Japan (1406-03)T Code No. 2CE-MQXH-5 This brochure is printed on recycled paper made from 40% used material.