MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

Similar documents
MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: W2TS. Mini-MW Series

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: KS. Plug-in Signal Conditioners K-UNIT

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: M2DYS SEN TRONIC AG

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

MODEL: JB2. Plug-in Signal Conditioners M-UNIT

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.

[3] MOUNTING DIRECTION

MODEL: 47LV. Digital Panel Meters 47 Series

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

MODEL: M1EXT. with Display M1E Series

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: MRP6. Final Control Elements

MODEL: R30US4. Remote I/O R30 Series

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: 48NDV. Bargraph Indicators 48N Series

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: 48NDVD. Bargraph Indicators 48N Series

MODEL: DAST-20. Telemetering System

MODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5]

MODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5]

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements

MODEL: DLS. Telemetering System

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT


MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

JPQ2 PULSE ACCUMULATOR

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors

Process displays For standard signals, temperature, resistance measurement

MODEL: LTWT. Power Transducer Series LT-UNIT

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

MODEL: TC10EM. Temperature Controller TC10 Series

General Specifications

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

PA-850 PRESSURE TRANSDUCERS WITH AMP. PA R - N R2 FEATURES MODEL NUMBER DESIGNATION

General Specifications

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

General Specifications

MODEL: WL40MW1F. Wireless I/O WL40F Series

27/04/2015

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

PowerPlex Compact Module PP-C-COM24

Assembly. Front view. Parametrization interface. Power Bus

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

Signal conditioner - MACX MCR-UI-UI-NC

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

General Specifications

2017 Advanced Energy Industries, Inc. HITEK POWER MH60 SERIES VERSATILE HIGH-VOLTAGE POWER SUPPLY MODULES

SHIMADEN DIGITAL INDICATORS

Solid-state Twin Timer

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

Model Number Structure

OMRON MK-I / -S RELAY

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

DC/DC Converter G_S-2WR2 & H_S-2WR2 Series

MINI MCR-SL-UI-I-LP-NC

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

FC Series Signal Conditioners

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

General Specifications

CB Patent Protection RoHS

High capacity SSR, both tab and screw terminals available

Solid-State Digital Counter H7AN

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

10A to 40A hockey puck type FEATURES

PAD - Heavy Duty Differential Pressure Trasmitter

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Multi Function Timer with Free power, Compact size W38 H42mm

TZIF 4. Current-to-Pulse Converter 10/ EN

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Operating Instruction

WJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable)

SHIMADEN DIGITAL INDICATORS

Transcription:

Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking Typical Applications Switching V DC signal: no contact failure that happens when using mechanical contacts for this purpose Switching low-speed pulse signals Model 9. (.6) 6 (.99) M: 00 0 V AC (Operational voltage range 6 V, 66 Hz) DC Power R: V DC (Operational voltage range V ±0 %, ripple 0 %p-p max.) R: V DC (Operational voltage range V, ripple 0 %p-p max.) (Select /N for Standards & Approvals code.) P: 0 V DC (Operational voltage range 0 V, ripple 0 %p-p max.) [] OPTIONS (multiple selections) Standards & Approvlas (must be specified) /N: Without CE /CE: CE marking Other Options blank: none /Q: Option other than the above (specify the specification) (.) mm (inch) -[][]-[3][] SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C0: Silicone coating /C0: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S0: Stainless steel ORDERING INFORMATION Code number: MMNV-[][]-[3][] Specify a code from below for each [] through []. (e.g. MMNV--M/CE/Q) Specify the specification for option code /Q (e.g. /C0/S0) Note: Must be used with its socket. NOT installable to a multi-unit installation base. (e.g. model: MBS-6) [] SWITCHING CONTROL : Interlocking switching control (single-pole contact) : Independent switching control (double-pole contact) [] INPUT : Current signal (no receiving resistor) : Current signal (receiving resistor 0 Ω) 3: Voltage signal [3] INPUT AC Power M: 6 V AC (Operational voltage range 6 V, 66 Hz) (Select /N for Standards & Approvals code.) GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3 screw terminals (torque 0. N m) Housing material: Flame-resistant resin (black) Switching: Photo MOS relay Isolation: Signal channel to switching command contact to power Power indicator LED: Green light turns on when the power is supplied. Status indicator LED : Green light turns on when the signal channel (A-B) is alive. Status indicator LED : Green light turns on when the signal channel (A-B) is alive. INPUT & OUTPUT Signal Channels Max. operational voltage range: ±0 V DC (min. span 0 mv) Max. operational current range: ±0 ma DC (min. span ma) Receiving resistor: 0 Ω incorporated (input code ) ON resistance: 0 Ω per wire (ON resistance of photo MOS relay) http://www.m-system.co.jp/ MMNV SPECIFICATIONS ES-09 Rev. Page /6

Output Current signal input (no receiving resistor): Equal to the input signal Current signal input (receiving resistor 0 Ω): Voltage signal equal to [Current 0 Ω] Voltage signal input: Equal to the input signal Switching Command: Relay or open collector Contact detecting: V DC / ma Detecting levels: kω at ON / 0 kω at OFF insulation (300 V) INSTALLATION Power Consumption AC Power input: Approx. 3 VA at 00 V Approx. VA at 00 V Approx. VA at 6 V DC power input: Approx. W Operating temperature: - to + C (3 to 3 F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 0 g (0.33 lbs) PERFORMANCE in percentage of span Accuracy: ±0. % (input code ) Temp. coefficient: ±0.00 %/ C (±0.006 %/ F) (input code ) Switching response time: msec. Leakage current at open circuit: μa Line voltage effect: ±0. % over voltage range Insulation resistance: 00 MΩ with 00 V DC (signal channel to switching command contact to power) Dielectric strength: 000 V AC @ minute (switching command contact to power to ground) 000 V AC @ minute (signal channel to power to ground) 00 V AC @ minute (signal channel to switching command contact) STANDARDS & APPROVALS CE conformity: EMC Directive (00/0/EC) EMI EN 6000-6-: 00 EMS EN 6000-6-: 00 Low Voltage Directive (006/9/EC) EN 600-: 00 Installation Category II Pollution Degree Signal channel or switching command contact to power: Reinforced insulation (300 V) Signal channel to switching command contact: Basic http://www.m-system.co.jp/ MMNV SPECIFICATIONS ES-09 Rev. Page /6

EXTERNAL VIEW Channel Status LED Channel Status LED Power LED DIMENSIONS unit: mm (inch) 6 (.3) 0. (.) DIN RAIL 3mm wide.x (.x.0) MTG HOLE 6 (.) deep 6 3 9 (.3) (.3) M3 SCREW 9 0. (.) 0 (.39) (3.3) (.9) [ (.6)] (.) 9. (.6) (.6) When mounting, no extra space is needed between units. http://www.m-system.co.jp/ MMNV SPECIFICATIONS ES-09 Rev. Page 3/6

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM INTERLOCKING SWITCHING CONTROL (single-pole contact) A- A- 0Ω * * B- B- A- A- 0Ω * V LED LED LED kω SWITCHING COMMAND SW 3 6 Photo MOSFET Relay Driver 0 U(+) V( ) 9 Base Socket *. Provided only with the input code : Current signal (receiving resistor 0Ω). *. Provided only with the input code : Current signal (no receiving resistor). */* Not provided with the input code 3. A-B channel is connected when the SW is turned on (closed). A-B channel is connected when the SW is turned off (open). INDEPENDENT SWITCHING CONTROL (double-pole contact) A- A- 0Ω * * B- B- A- A- 0Ω * V LED LED LED SWITCHING COMMAND SW SW 3 6 9 V kω kω Photo MOSFET Relay Driver 0 U(+) V( ) Base Socket *. Provided only with the input code : Current signal (receiving resistor 0Ω). *. Provided only with the input code : Current signal (no receiving resistor). */* Not provided with the input code 3. A-B channel is connected when the SW is turned on (closed). A-B channel is connected when the SW is turned on (closed). http://www.m-system.co.jp/ MMNV SPECIFICATIONS ES-09 Rev. Page /6

SWITCHING OPERATIONS INTERLOCKING SWITCHING CONTROL (single-pole contact) Single contact is used to switch from Signal Channel (A-B) to Signal Channel (A-B) and vice versa. CHANNEL (A) CHANNEL (A) Terminal 3 9 OFF (open) OFF ON Terminal 3 9 ON (closed) ON OFF Status LED turn on when the respective channels are alive. Switching Status Current Signal (no receiving resistor) Current Signal (receiving resistor 0Ω) Voltage Signal * Power : OFF Switching command : OFF (open) * * Switching command : OFF (open) * * Switching command : ON (short) * *. Resistor is provided only for the input code : Current signal (receiving resistor 0Ω). Current Signal (no receiving resistor) Transition (ON to OFF, OFF to ON) Status Current Signal (receiving resistor 0Ω) Voltage Signal * Switching command : OFF to ON or Switching command : ON to OFF When the switching command contact is switched from OFF to ON or from ON to OFF, the signal channel is switched only after all photo MOS relays turn on (closed). * When the switching command contact is switched from OFF to ON or from ON to OFF, the signal channel is switched only after all photo MOS relays turn off (open). *. Resistor is provided only for the input code : Current signal (receiving resistor 0Ω). INDEPENDENT SWITCHING CONTROL (double-pole contact) Double contacts are used to independently switch Signal Channel (A-B) and Signal Channel (A-B). CHANNEL (A) CHANNEL (A) Terminal 3 9 OFF (open) OFF ---- Terminal 3 9 ON (closed) ON ---- Terminal 6 9 OFF (open) ---- OFF Terminal 6 9 ON (closed) ---- ON Status LED turn on when the respective channels are alive. http://www.m-system.co.jp/ MMNV SPECIFICATIONS ES-09 Rev. Page /6

Specifications are subject to change without notice. http://www.m-system.co.jp/ MMNV SPECIFICATIONS ES-09 Rev. Page 6/6