TH008F Multi-function Infrared Forehead Thermometer

Similar documents
Powered Traction Unit OPERATION MANUAL

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

English

HeRO duet

BIODEX MULTI- JOINT SYSTEM

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

Operating Manual Infrared thermometer

D C 01/2019 3

General Safety/EMC and Electrical Information for i-limb ultra and i-limb digits

USER MANUAL MHS-2500I. Please take time to read these instructions before starting to use the scale. Version /17

Biological Safety. Electromagnetic Compatibility (EMC) Observe the following precautions related to biological safety.

Technical Specifications Micromedical VisualEyes 505 by Interacoustics

Nursing Beds with Dewert drive system

USER MANUAL M-200. Please take time to read these instructions before starting to use the scale. Version /06

INTRODUCTION. 4 SAFETY INSTRUCTIONS. 5 ABOUT THIS DEVICE. 6 FIRST OPERATION. 7 THE DISPLAY. 8 ATTACHING THE WRIST SLEEVE. 9 CORRECT MEASUREMENT.

User Instruction Computer Assisted Local Analgesia. 337 Marion, Le Gardeur QC, Canada, J5Z 4W8

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06

Rolyan Splint Pan OPERATION MANUAL. Item # Small Item # Large

VN415/VO425 Specifications

(c) Medisave UK. Notice. Edition 1. i-pad Operator s Manual

PHYSIOFLOW Q-LINK TM

DENTAL X-RAY OPERATOR'S INSTRUCTIONS. (for USA) Wall Mount Type...WK

MedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11

M-400 M-410 M-420 M-430

: 0089 GTIN

Technical Data. Electrocardiograph ECG-1250K TD.ECG1250_L. This technical data may be revised or replaced by Nihon Kohden at any time without notice.

Not for print. Microphone Test Device with SONNET MTD Adapter. User Manual. Cochlear Implants NOT FOR PRINT

L NKTEMP. Non-contact. Infrared Thermometer. User Manual LMP001

#

Exergen TAT 5000S RS232 TTL Supplemental Instructions for Use

The following languages can be found on our website: French. German. Spanish. Italian. Swedish. Portuguese. Russian. Dutch.

WRIST BLOOD PRESSURE MONITOR

INSTALLATION MANUAL AVANT HIT+ Hearing Instrument Test Chamber.

H2 Check Operating Manual

SAVI SCOUT Surgical Guidance System. Console Operation Manual

DIGITAL BLUETOOTH THEROMETER PBT

The following symbol indicates that the device is MR-unsafe:

ENGLISH. Important safety information Read this important information carefully before you use the device and save it for future reference.

USER S MANUAL Volk Pictor Plus Fluorescein Angiography (FA) Module For Use with: Volk Pictor Plus

CONTACTLESS THERMOMETER Thermo Checker

2015 Koninklijke Philips N.V. All rights reserved Philips Consumer Lifestyle BV Tussendiepen 4, 9206AD Drachten, Netherlands

Operator s Manual External Remote Controller (ERC)

AUTOMATIC BLOOD PRESSURE MONITOR (Arm Cuff Type) INSTRUCTION MANUAL

#0086.

INSTRUCTIONS FOR YOUR NEW PLASMAFLOW. Vascular Therapy System (Compressible Limb Sleeve Device)

GTIN:

Osmolarity System USER MANUAL FOR QUANTITATIVE MEASUREMENT OF OSMOLARITY OF OCULAR TISSUES. osdcare.com

Ceiling Model Ceiling Model for LEDview Plus and Heliodent Plus. Installation Requirements. New as of: English

SJM MRI Activator. Handheld Device. User's Manual. Model EX4000

Central Blood Pressure Meter Model cbp301. Operating Manual

BodyclockStimplusManual.qx8_Layout 1 17/08/ :53 Page 1. Body Clock Stimplus. Instructions for use

Rotating Anode X-Ray Tube Housing Assembly. General Data

POCKET AIR. Portable Nebulizer. Instruction Manual MBPN002 / MB / MB05006

Multi-Control Panel for built-in system. Multi Pad for NLX / imd OPERATION MANUAL OM-E0538E 001

Transcutaneous Electrical Nerve Stimulator

`bob`=p=^åèìáëáíáçå=råáí

User Manual. Before Using Your WiTouch Pro Device

OPERATOR S MANUAL AN APPLIED DIGITAL COMPANY

`bob`=p=^åèìáëáíáçå=råáí=bma

EXERGEN. English. TemporalScanner. Accurate Temperature with a Gentle Forehead Scan. Four Reasons to Standardize with Exergen Thermometers

ENG en. Operating instructions. Iris Magneton MF Wellness therapy

By Paul Aylett at 12:08 pm, Apr 13, 2016

OPERATOR S INSTRUCTIONS (for USA & Canada)

Welch Allyn Home Scale (T- RPM-SCALE100)

Draft. User s Manual. Transmitter Model EX1150

How to use the Barcode Scanner:

Wireless TENS Pain Reliever. WT1 Series

OPERATOR'S INSTRUCTIONS DX-073 DENTAL X-RAY

OPERATOR'S INSTRUCTIONS DENTAL X-RAY MODEL 096

JPD-FR302. User Manual. Infrared Thermometer

Transmitter Model EX1100, EX1100W. User's Manual

Non-contact Forehead IR Thermometer

TM Machine WetAlert TM Wireless Wetness Detector In-center User s Guide

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

Product Name: COMPER SMART DOPPLER FETAL MONITOR. Product Model: DFMX

IEC Second Edition

Operation Guide Model: 405-HT V3.0

Nerve stimulator TWISTER

User instructions for the ABI-system 100

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

Pain Management System

User's Manual. LEICKE Sharon Blood Pressure Monitor with Bluetooth. Product number: LH67402

HD STETH TM Quick Start User Guide

The Symbol means that the Vet-Tech (200, 250 or 300HF) system intentionally applies some radioelectric energy for diagnostic or treatment purposes.

User Manual. Glass Body Fat Analyzer LS203-B. version:1.0

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

Relief. At Last. User Manual For an effective treatment, read the entire User Manual before using Kyrobak.

TEST REPORT... 1 CONTENT...

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

CardioMessenger II-S Transmitter for BIOTRONIK Home Monitoring. Technical Manual

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Compressor Nebulizer. Model No: 9R-021 series. Please read the instruction manual before use.

EICKEMEYER INFUSION WARMER

ibed Locator Model 5212

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

RF (RADIO FREQUENCY) WIRELESS PENDANT

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

Body Clock Stimplus Pro

2620 Modular Measurement and Control System

Transcription:

TH008F Multi-function Infrared Forehead Thermometer Specifications Functions Temperature measurement range: Forehead mode: 34~42.2 C (93.2~108 F), Surface mode: -22~80 C (-7.6~176 F) Operating temperature range: 10~40 C (50~104 F) Storage temperature range: It should be stored at room temperature between -20~+50 C, RH 85% Transportation temperature shall be less than 70 C, RH 95% Comply with ASTM E1965-98, IEC/EN60601-1-2(EMC), IEC/ EN60601-1(Safety) standards. Accuracy: For forehead mode: +/-0.2 C (0.4 F) within 36~39 C (96.8~102 F), +/-0.3 C (0.5 F) for other range. For surface mode: +/-0.3 C (0.5 F) within 22~42.2 C (71.6~108 F), others +/-4% or +/-2 C (4 F) whichever is greater. Fever alarm & Memory locations under Forehead mode (with each measurement date/time/mode icon) Real time clock, C / F Switch mode Battery: one lithium cell battery (CR2032 *1pcs) This thermometer converts the forehead temperature to display its oral equivalent. There is no gender and age limitation for using infrared thermometer. This is not an AP or APG product. Do not use this device for Live & Dead decision or Safety related applications. Please consult with doctor if you have health concerns. Real Time Clock Room Temperature Forehead Temperature Surface Mode Stopwatch Fever Alarm Memory Locations C / F Switch The real time clock will be recorded with the memory function and help you to recognize each measurement result. (It includes the 12/24 Format_Hour_Minutes_Date.) Please see the Real time clock setting section to learn how to setup the time in the first use. Suitable ambient temperature is important for the baby and patient, the thermometer always help you recognize the room temperature. Setting Real time clock first to enable this function. After power off, room temperature will be shown on the screen with icon. Please see the Use of the thermometer section to learn how to get the correct room temperature. The thermometer has been designed for practical use. It s not meant to replace a visit to the doctor. Please also remember to compare the measurement result to your regular body temperature. Please see the Use of the thermometer section to learn how to measure the body temperature. The surface mode shows the actual, unadjusted surface temperatures, which is different from the body temperature. It can help you to monitor if the object temperature is suitable for the baby or patient, for example the baby s milk. Please see the Use of the thermometer section to learn how to measure the object temperature. The thermometer built the stopwatch function to help you to monitor the heartbeat since heartbeat is one of the healthy indexes for people. Please see the Use of the Stopwatch section to learn how to measure the heartbeat result. If thermometer detects a body temperature 37.5 C under forehead mode, there will be a long beep sound followed by three short beep sound to warn the user for potential fever. There are total 9 sets memories for forehead measurements. Each memory also records the measurement date/time/mode icon. When in power on, Press the ON/MEM button to see the temperature stored with icon. In power off mode (The LCD only shows the date, time and room temperature). Press and hold the SCAN button, then immediately press and release the ON/MEM button. After 3 seconds, icon C will be switched to icon F. (You may use the same way to switch back to C ) Real time clock setting 1. Power on: Press the ON/MEM button. The thermometer is ready for use after hearing two beep sounds. 2. Press and hold the ON/MEM button for 5sec. When you see the Set icon starts flashing, it indicates that you are in the setting screen.(see the following figure.) 3. Press the SCAN button to make the 24 icon flash. This indicates that you are in the 12/24-hour setting screen. Press the SCAN button to set 12/24-hour Format from 24 (24-hour) to 12 (12-hour). 4. Press ON/MEM button to move the flashing in the sequence shown below to select our settings: hour minutes year month day leave the setting screen. 5. While the hour, minutes, year, month, day setting is flashing, use SCAN button to change it. Use of the thermometer 1. Always make sure the probe is clean, and without damage. 2. Power on: Press ON/MEM button.(see figure 1) Figure 1 Figure 2 Figure 3

3. Mode selection: 3.1 Forehead mode: The preset mode of thermometer. The thermometer is ready for use after you see the temperature by forehead measurement. (see figure 1) icon on the screen and hear two beep sounds. In this mode, you can get the body 3.2 Surface mode: Press and hold the ON/MEM button, and press the SCAN button for Infrared thermometer mode. On your LCD display, icon will replace icon. In this mode, you can get the target surface temperature. (see figure 2) 3.3 Stopwatch: Press and hold the ON/MEM button, and press the SCAN button twice for stopwatch mode. On your LCD display, icon will replace icon. In this mode, you can count by 0.01sec to 3 minutes. (see figure 3) 4. Temperature taking: 4.1 Body temperature: Remarks: 1. Forehead temperature is displayed in oral mode. This mode converts the forehead temperature to display its oral equivalent. 2. Before the measurement, please stay in a stable environment for 5mins and avoid exercise, bath for 30mins. 3. Remember to keep the temple area clean and away from sweat, cosmetics and scar while taking temperature. Figure 4.1.1 Figure 4.1.2 Figure 4.1.3 4.1.1 The temporal artery is connected to the heart via the carotid artery. It is designed to measure the skin surface around temporal artery, a major artery of the head (Fig.4.1.1). 4.1.2 Attach the thermometer to the required measurement location on the forehead (Fig. 4.1.2). (You can choose left or right temple.) 4.1.3 Press the SCAN button, and gently scan around the temple area (Fig. 4.1.3). While scanning, you will hear a beep sound, which indicates you the newest measurement is taking place. Measurement has been completed after two short beeps are heard and the forehead icon stops flashing. The time consuming for measurement might be between 5~8 sec (up to 30sec). It depends on how much time the device needs to get the correct forehead temperature. 4.2 Surface mode for object temperature: 4.2.1 When you press the SCAN button, you will get the real time temperature immediately. If you press and hold the SCAN button, the reading of measurement will be continuous updated. 4.2.2 Applications include temperature measurements for Water, Milk, Cloth, Skin or other object. Note: This mode shows the actual, unadjusted surface temperatures, which is different from the body temperature. 4.3 Get the room temperature: 4.3.1 Setting Real time clock first to enable this function. After power off, room temperature will be shown on the screen with icon. 4.3.2 For room temperature, the thermometer should be placed on the table and avoid the direct sunshine or air conditioner flow on. 4.3.3 The room temperature can be reference after 15min later. 5. After measurement: 5.1 Power off: Device will automatically shut off if left idle for more than 1 minute to extend battery life. The LCD will only show the date, time and room temperature. 5.2 Clean the probe after each use to ensure an accurate reading and avoid cross contamination. (See the section of Care and Cleaning for details.) 5.3 Remember to put on the Probe Cap when not in use. Use of the Stopwatch 1. Press and hold the ON/MEM button, and press the SCAN button twice for stopwatch mode. 2. For start or stop counting, press the SCAN button; for reset counting, press the ON/MEM button. 3. Press and hold the ON/MEM button, and press the SCAN button to enter the forehead mode. 4. How to measure the heartbeat? If you count out the number of beating is 18 in 15sec, then you can calculate the heartbeat of patient is 72 times in 1min. Important Notes Care and cleaning The probe is the most delicate part of the thermometer. Use with care when cleaning the probe lens to avoid damage. a. After each use, use the 70% alcohol swab or the soft cotton moistened with the 70% alcohol to clean the Probe and Lens. b. Allow the lens to fully dry for at least 1 minute. c. Keep the unit dry and away from any liquids and direct sunlight. d. Storage temperature range: It should be stored at room temperature between -20~+50 C, RH 85%. Holding the thermometer too long may cause a higher ambient temperature reading of the probe. This could make the body temperature measurement lower than usual. Battery replacement Keep the battery away from children. (This device is supplied with one lithium cell (CR2032x1).) 1 Open the battery cover: Insert a pointed object, such as a pen, into battery cover pick hole. At the same time, use thumb to push battery cover out. 2 Hold the device and flip the battery out with a small screwdriver 3 Insert the new battery under the metal hook on the left side and press the right side of the battery down until you hear a click * The positive (+) side up and the negative (-) side pointed down. 4 Replace the battery cover

Trouble shooting: Error Message Problem Solution Error 5~9, the system is not functioning properly. Unload the battery, wait for 1 minute and repower it. If the message reappears, contact the retailer for service. Measurement before device stabilization. Wait until all the icons stops flashing. The device showing a rapid ambient temperature change. The ambient temperature is not within the range between 10 o C and 40 o C (50 o F ~104 o F). Allow the thermometer to rest in a room for at least 30 minutes at room temperature: 10 o C and 40 o C (50 o F ~104 o F). (1) In forehead mode: Temperature taken is higher than +42.2 o C (108 F). (2) In surface mode: Temperature taken is higher than +80 o C (176 F). (1) In forehead mode: Temperature taken is lower than +34 o C (93.2 F). (2) In surface mode: Temperature taken is lower than 22 o C (-7.6 F). Please select the target within specifications. If a malfunction still exists, please contact the nearest retailer. Device cannot be powered on to the ready stage. Change with a new battery. Warranty Warranty :12 months Manufacture Date:as the serial number( please open the battery cover, it is shown on the inside of the device.) Ex.SN:E912A000001, the first E is External, the second number 9 is the manufacture year 2009, the third and the fourth number 12 is the manufacture month, the others is the serial number. Note: The thermometer is calibrated at the time of manufacture. If at any time you question the accuracy of temperature measurements, please contact the dealers or nearest service address. Please read the instructions for use BF type applied part Radiant Innovation Inc. Http://www.radiantek.com.tw Add: 1F, No.3, Industrial East 9 th Road, Science-Based Industrial Park, HsinChu, Taiwan 300. Medical Technology Promedt Consulting GmbH Add: Altenhofstrasse 80, D-66386 St. Ingbert, Germany Ref No.:082012

Symbol Descriptions The CE mark and Notified Body Registration Numbers, the requirement of Annex II from Medical Device Directive 93/42/EEC are met. Indicates this device is subject to the Waste Electrical and Electronic Equipment Directive in the European Union. To protect the environment, dispose of useless device at appropriate collection sites according to national or local regulations. Authorized representative in the European community Caution Please read the instructions for use Manufacturer BF type applied part Battery Recycling Paper Recycling Guidance and manufacturer s declaration electromagnetic emissions Emissions test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 The TH00xy series uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions CISPR 11 Harmonic emissions IEC 61000-3-2 Voltage fluctuations/ flicker emissions IEC 61000-3-3 Class B The TH00xy series is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Guidance and manufacturer s declaration electromagnetic immunity Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Portable and mobile RF communications equipment should be used no closer to any part of the TH00xy series, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Conducted RF IEC 61000-4-6 3 Vrms 150 khz to 80 MHz Not applicable Recommended separation distance 80 MHz to 800 MHz d = 2,3 800 MHz to 2,5 GHz Radiated RF IEC 61000-4-3 3 V/m 80 MHz to 2,5 GHz 3 V/m where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range b. Interference may occur in the vicinity of equipment marked with the following symbol: NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the TH00xy series is used exceeds the applicable RF compliance level above, the TH00xy series should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the TH00xy series. b. Over the frequency range 150 khz to 80 MHz, field strengths should be less than 3 V/m.

Guidance and manufacturer s declaration electromagnetic immunity Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge (ESD) IEC 61000-4-2 Electrical fast transient/burst IEC 61000-4-4 Surge IEC 61000-4-5 6 kv contact 8 kv air 2 kv for power supply lines 1 kv for input/output lines 1 kv line(s) to line(s) 2 kv line(s) to earth 6 kv contact 8 kv air Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. or hospital environment. or hospital environment. <5 % UT (>95 % dip in UT) for 0,5 cycle interruptions and voltage variations on power supply input lines IEC 61000-4-11 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles or hospital environment. If the user of the TH00xy series requires continued operation during power mains interruptions, it is recommended that the TH00xy series be powered from an uninterruptible power supply or a battery. <5 % UT (>95 % dip in UT) for 5 sec Power frequency (50/60 Hz) magnetic field IEC 61000-4-8 3 A/m 3 A/m NOTE UT is the a.c. mains voltage prior to application of the test level. Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. Recommended separation distances between portable and mobile RF communications equipment and the ME EQUIPMENT or ME SYSTEM The TH00xy series is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the TH00xy series can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the TH00xy series as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter W 150 khz to 80 MHz Separation distance according to frequency of transmitter m 80 MHz to 800 MHz 800 MHz to 2,5 GHz d = 2,3 0,01 0,12 0,12 0,23 0,1 0,38 0,38 0,73 1 1,2 1,2 2,3 10 3,8 3,8 7,3 100 12 12 23 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.