1 Operating Manual Infrared thermometer Model:IT-121 Professional Fast Accurate 1

2 CONTENTS 1 I n t r o d u c t i o n Product intended use 3 2 Basic principle 3 3 Pr o d u c t f e a t u r e 3 4 Te c h nical pa r a meters 4 5 Shape structure 4 6 Display icon definition 5 7 F u n c t i o n k e y s 6 8 Se t tings 7 9 Measuring method 7 9.1Forehead temperature measurement E a r t e m p e r a t u r e m e a s u r e m e n t Object temperature measurement Ambient temperature measurement Replacement of batteries Maintenance and matters needing attention Troubleshooting Commitment to quality and after-sales service Manufacturer information

3 1. Introduction IT-121 measures the body temperature through receiving the infrared energy radiation from the surface of objects. It is with forehead temperature mode,and ear temperature mode. The measurement result directly shows on the LCD screen It is easy, hygiene and accurate. The device is widely used for home healthcare, medical institutes and many other occasions. The product is mainly composed with infrared temperature sensors, signal receiving processor, buttons, buzzer, LCD display, battery, etc 1.1 Product intended use The infrared thermometer is intend for the measurement and monitoring of human body temperature by doctor or customers in the hospital or home, it is used alone for human beings for all ages. 2. principle Any object in which temperature is higher than absolute zero degree will transmit some infrared radiation energy according to its own temperature. The radiation energy and its distribution per wavelength are closely associated with its surface temperature. Based on the principle, it is possible to measure the forehead surface temperature and then adjust the offset between forehead temperature and actual body temperature, which will result in the correct display of body temperature. 3. Product features Contact-type infrared measurement; Forehead, Eear temperature, dual modes of measurement; Hi definition dual color LED backlit, clearly and softly display Fever alarm function (defaut alarm value is 38.0 C and above) Capacity of storing 20 sets measurements; Dual temperature units Cesis and Fahrenheit optional. Automatic shut-down and power-saving. 3

4 4. Technical parameters Measurement method Measurement Mode 5. Shape structure Contact-Type Body Mode Surface Mode Measurement accuracy Body Mode ±0.3 C(0.54 F) Surface Mode ±1.0 C(1.8 F) Display resolution Operating environment Storage condition Power supply Power consumption Auto power-off Dimensions Weight Dimensions 0.1 C/ F 16 C ~ 35 C (60.8 F to 95 F) 85% moisture condensation - 25 ~ 55 C - (-13 F to 131 F) 90% moisture condensation DC1.5V 2 When off 10 uw When measuring 30 mw In 30 seconds 30mm * 44 mm *152 mm(length x width x height) About 72 g (without battery) 152mm * 44 mm *30mm(length x width x height) Table1 1. Mode conversion cover; 2. Infrared probe; 3. Measuring key; 4. LCD display; 5. Memories key and conversion key 6. handle 7. Battery cover 32.0 C~42.9 C(89.6 F~109.2 F) 0 C~100 C(32 F~212 F) 4

5 6. Display icon definition Table 2 Icon definition icon Definition Measuring mode1 Measuring mode2 Forehead and Object temperature Ear temperature measurement Temperature unit F or C Celsius degree; Fahrenheit degree Ambient Mode. Battery capacity The icon means can convert between F and C Ambient temperature measurement Indicates low battery status Memory symbol M Record the latest 20sets memories Read the manual before use Precautions for use Don t dispose with household waste after use Flammable and explosive Manufacturer BF type application device Keep dry Upward 5

6 Fragile, handle with care IS LOVE 7. Function keys Table 3 Function key Measuring key Memories key Conversion key functional description Press to measure Press to get the latest 20 sets memories temp. Keeping press in 5s to adjust C / F, when setup 8. Settings A: Memory mode: 6

7 Open the battery cover and install the batteries, then the screen display all symbols. press the Memory key to check the lastest 20 sets measurement value. Note: a. The record order is 20,19, and so on. b. The record will be deleted when uninstall the batteries. B: Temperature unit setting: Open the battery cover and install the batteries, then the screen display all the symbols and off. Press the memory key for 5s and the screen display C, press the memory key one more time to change into F and off after 3s. then the setting is done. Note: The default temperature unit is C. The setting will come back to the default when uninstall the batteries. 9. Measuring method 9.1 Forehead temperature measurement. Install the batteries to power on, make sure the screen display and the mode conversion cover before the measurement. Hold the thermometer and point the device to the forehead, measurement key directly or keep pressing measurement key, scan forehead,when buzzer beeps, the temp.will display on the LCD screen.keep the probe cover contacting the forehead when measuring. 9.2 Ear temperature measurement Take off the mode conversion cover, then put on the ear probe cover.insert the probe into the ear. Press the measuring key to measure directly,when the buzzer beeps, the temperature will display on the screen. Make sure that the probe cover is taken off and converted to the Ear and ambient measuring mode 7

8 Prompt Don t push hard into the ear to avoid hurting the eardrum 9.3 The object temperature measurement. Take off the Cover of mode conversion, point the thermometer to the object, keep the probe 3~5mm to the object. Press the measuring key to measure directly,when the buzzer beeps, the temperature will display on the screen. Make sure that the cover of mode conversion is taken off and converted to the Ear and the object mode. Prompt 1. All operation should do when power on; 2. All settings will come to default when uninstall the batteries. If need adjust the settings, please power on and make the new settings.. 3. Temperature unit setting must in the state of power off. 4. Memory value can be inquired when power off or any measurement mode according to 8 (B) 5. The thermometer will be auto off after 30s when idle. 6. Measurement must be carried out when power on and the backlight is off. 7. When the measured temperature value is 38 and above, the backlight is red and beep while the other value is green. When the measurement vale is between , it is considered low fever, advice to consult the doctor. 9.4 Ambient temperature measurement 1.Take off the mode conversion cover. 8

9 2.point the prove to the air and press the start key. 10. Replacement of batteries The battery life is approx readings one year and 90 minutes when in constant use. Open the battery cover, and remove the old battery. Put in new battery, and take care of the direction of the electrodes. Prompt 1.when not used for a long time, please take out the battery to prevent leakage. It is forbidden to put waste battery in the fire. 2. According to local regulations, properly handle the waste batteries to avoid pollution. 11. Maintenance and matters needing attention Please keep the inner cavity of the sensors and probes clean, otherwise it will affect the measuring accuracy. Cleaning methods: 1. The device only needs routine cleaning, and period or times can be decided according to user s need. 2. The surface cleaning: use a clean soft cloth or cotton swab stick moistened with a little medical alcohol or water to wipe the dirt. 3. Probe and sensor inner cavity cleaning: with a clean soft cloth or cotton swab dipped with a little medical alcohol gently wipe the probe at the top of the inner cavity or sensors, and do not use until the alcohol completely evaporates. Before use, please read the instructions, and make sure the battery has been installed. Prohibit the thermometer into any liquid, no long time use in high or low temperature environment. No collision, falling and sharp objects mix, it is forbidden to disassemble the thermometer. Do not use in strong electromagnetic interference environment. The thermometer is placed in the position not touched by children. Practice is suggested to get familiar with the measurement methods; try not to change the product factory settings. The measurement results cannot replace the physician diagnosis. Use the thermometer in a stable temperature environment. If the environment temperature changes too much, for example from outdoor to indoor, please put the thermometer and wait for about half an hour minutes before measuring. 9

10 Don't measure body temperature after measuring extremely high or low temperature. Put the device for 10 minutes before measuring. Try to avoid using the thermometer when drying the hair, drenching water, sweating, and putting on skin cosmetics. Don t measure the temperature after doing sports, washing and 30 minutes before dinner. No special maintenance is needed to the use process. Please contact the vendor or manufacturer for fault. 12. Troubleshooting Diagnosis The screen shows "Lo" or "Hi Table 4 Solution 1.Check the measurement object. It is unable to ensure the measurement of the forehead hair, water, sweating, and applying cosmetics case. 2.Check the operation environment. Environment changes will greatly influence the measurement. 3.Temperature change is too big or the thermometer tests target of low temperature immediately after being switched from a high temperature measuring. It's better to use after 10 minutes to achieve a new heat balance. 4. The measured body temperature is higher than 42.9 C or lower then 32.0 C 5. The measured object is not corrent. The screen shows "Er1 Buttons have no response No display or display abnormal Power off when open 1. The environment temperature is exceed the normal working arrange which is 16 C ~ 35 C (60.8 F to 95 F) 2. Load and unload the battery 3. Check if the setting is in the progress Unload the batteries and load again Check the battery, load and unload the battery again 10

11 Table 5 Guidance and manufacturer s declaration-electromagnetic emissions The IT-121 is intended for using in the electromagnetic environment specified below. The customer or the user of theit-121 should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment-guidance RF emissions CISPR 11 Group 1 RF emissions CISPR 11 Class B TheIT-121 uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause and interference in nearby electronic equipment. Harmonic emissions IEC Voltage fluctuations /flicker emissions IEC N/A N/A TheIT-121 is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Table 6 Guidance and manufacturer s declaration-electromagnetic immunity TheIT-121 is intended for use in the electromagnetic environment specified below. The customer or the user of theit-121 should assure that it is used in such an environment. Immunity test Electrostatic discharge (ESD) IEC Electrical fast transient/burst IEC IEC60601 test level ±2,±4,±6kV for Contact discharge ±2,±4,±8kV air discharge ±2 kv for a.c. power lines ±1 kv for d.c. power lines Compliance level ±2,±4,±6kV for Contact discharge ±2,±4,±8kV N/A Electromagnetic environment -guidance Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30% Mains power quality should be that of a typical commercial or hospital environment. Surge IEC ±1 kv line(s) to line(s) ±2 kv line(s) to earth N/A Mains power quality should be that of a typical commercial or hospital environment. 11

12 Voltage dips, short interruptions and voltage variations in power supply <5%UT (>95 dip in UT) for 0.5 cycle 40% UT (60% dip in UT) for 5 cycles input lines IEC % UT (30% dip in UT) for 25 cycles N/A Mains power quality should be that of a typical commercial or hospital environment. If the user of theit-121 requires continued operation during power mains interruptions, it is recommended that theit-121 be powered from an uninterruptible power supply or a battery Power frequency (50/60Hz) magnetic field IEC <5% UT (>95% dip in UT for 5 s 3 A/m 3 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment NOTE UT is the a.c. mains voltage prior to application of the test level. Table 7 Guidance and manufacturer s declaration-electromagnetic immunity The IT-121 is intended for use in the electromagnetic environment specified below. The customer or the user of the IT-901 should assure that it is used in such Compliance an environment. Immunity test IEC test level Electromagnetic environment-guidance level Conducted RF IEC Vrms 150kHz to 80MHz N/A Portable and mobile RF communications equipment should be used no closer to any part of theit-121 including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance d=1.2 P 12

13 Radiated RF IEC V/m 80kHz to 2.5GHz 3V/m d=1.2 P 80MHz to 800MHz d=2.3 P 800MHz to 2.5MHz Here P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths form fixed RF transmitters, as determined by an electromagnetic site survey, should be less than the compliance b level in each frequency range. Interference may occur in the vicinity of equipment marked with the following symbol: NOTE 1 At 90MHz and 800MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a b Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, anelectromagnetic site survey should be considered. If the measured field strength in the location in which theit-121 is used exceeds the applicable RF compliance level above, theit-121 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating theit-121 Over the frequency range 150kHz to 80MHz, field strengths should be less than 3V/m. Table 8 Recommended separation distances between portable and mobile RF communications equipment and the IT-121 TheIT-121 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of theit-121 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and theit-121 as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter W Rated maximum output power of transmitter 150kHz to 80MHz d =1.2 P Separation distance according to frequency of transmitter m 80MHz to 800MHz d =1.2 P 800MHz to 2.5GHz d =2.3 P

14 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1 At 80MHz and 800MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. 13. Commitment to quality and after-sales service This product provides 3 year free maintenance service. Note: The free service does not include the failure and damage due to user s personal reasons or unauthorized disassembling. Prompt Please keep the purchase vouchers to facilitate future maintenance. 14. Manufacturer information Shenzhen Brav Electronic Technologies Co., Ltd. Address: 4/F, Block 11, Tongfuyu Industrial District, Lezhujiao, Jiuwei, Hangcheng, Baoan, Shenzhen, P.R. China Tel: Fax:

HeRO duet

HeRO duet HeRO duet CUSTOMER SERVICE TABLE OF CONTENTS TABLE OF CONTENTS OVERVIEW OVERVIEW OVERVIEW OVERVIEW USING HeRO duet USING HeRO duet USING HeRO duet Current HeRO Score HeRO USING HeRO duet USING HeRO duet

More information

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi TS ii ortable Tourniquet System Guidance and manufacturer s declaration electromagnetic emissions The TS ii ortable Tourniquet

More information

TH008F Multi-function Infrared Forehead Thermometer

TH008F Multi-function Infrared Forehead Thermometer TH008F Multi-function Infrared Forehead Thermometer Specifications Functions Temperature measurement range: Forehead mode: 34~42.2 C (93.2~108 F), Surface mode: -22~80 C (-7.6~176 F) Operating temperature

More information

BIODEX MULTI- JOINT SYSTEM

BIODEX MULTI- JOINT SYSTEM BIODEX MULTI- JOINT SYSTEM CONFORMANCE TO STANDARDS 850-000, 840-000, 852-000 FN: 18-139 5/18 Contact information Manufactured by: Biodex Medical Systems, Inc. 20 Ramsey Road, Shirley, New York, 11967-4704

More information

English

English English Specifications Type Power Source Vibration Frequency Maximum Output Power Consumption Water Pressure Lighting NE134 AC120V 50/60Hz AC230V 50/60Hz 28~32kHz 8W Max. 42VA 0.1~0.5MPa (1~5kgf/cm

More information

Powered Traction Unit OPERATION MANUAL

Powered Traction Unit OPERATION MANUAL Powered Traction Unit OPERATION MANUAL CONTENTS Symbols Safety precautions Symbol for CAUTION Symbol for CONSULT INSTRUCTIONS FOR USE Symbol for SERIAL NUMBER Symbol for CATALOGUE NUMBER Symbol for AUTHORISED

More information

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007) Compressor set Equipment Under Test (EUT) Type 028 Type 047 Type 052 Type 085 Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN 60601-1-2:2007 (IEC 60601-1-2:2007) 2017 PARI

More information

General Safety/EMC and Electrical Information for i-limb ultra and i-limb digits

General Safety/EMC and Electrical Information for i-limb ultra and i-limb digits 1. General Safety 1.1 The i-limb ultra and i-limb digits devices are electrical devices, which under certain circumstances could present an electrical shock hazard to the user. Please read the accompanying

More information

Rolyan Splint Pan OPERATION MANUAL. Item # Small Item # Large

Rolyan Splint Pan OPERATION MANUAL. Item # Small Item # Large Rolyan Splint Pan OPERATION MANUAL Item #081544816 - Small Item #081544808 Large PLEASE READ THIS ENTIRE MANUAL BEFORE OPERATING YOUR NEW SPLINT PAN. Failure to follow these instructions could result in

More information

USER MANUAL MHS-2500I. Please take time to read these instructions before starting to use the scale. Version /17

USER MANUAL MHS-2500I. Please take time to read these instructions before starting to use the scale. Version /17 USER MANUAL MHS-2500I Please take time to read these instructions before starting to use the scale Version 1.0 05/17 Contents Introduction 3 Product Specification 3 Safety Instructions 4 Explanation of

More information

Technical Specifications Micromedical VisualEyes 505 by Interacoustics

Technical Specifications Micromedical VisualEyes 505 by Interacoustics VisualEyes 505 - Technical Specifications Page 0 Technical Specifications Micromedical VisualEyes 505 by Interacoustics D-0115523-B 2018/02 VisualEyes 505 - Technical Specifications Page 1 Included and

More information

Biological Safety. Electromagnetic Compatibility (EMC) Observe the following precautions related to biological safety.

Biological Safety. Electromagnetic Compatibility (EMC) Observe the following precautions related to biological safety. Biological Safety Observe the following precautions related to biological safety. WARNING: Non-medical (commercial) grade peripheral monitors have not been verified or validated by SonoSite as being suitable

More information

D C 01/2019 3

D C 01/2019 3 D-0117968-C 01/2019 3 4 D-0117968-C 01/2019 Screw Driver Screw Driver Unplug both the Red & Blue connectors. (see above) Place a small flat head screw driver on the small orange tabs and push down while

More information

L NKTEMP. Non-contact. Infrared Thermometer. User Manual LMP001

L NKTEMP. Non-contact. Infrared Thermometer. User Manual LMP001 L NKTEMP Non-contact Infrared Thermometer User Manual LMP001 TABLE OF CONTENTS Product Description Intended Use Product Features Safety Precautions Using the Thermometer Taking a Measurement Temperature

More information

(c) Medisave UK. Notice. Edition 1. i-pad Operator s Manual

(c) Medisave UK. Notice. Edition 1. i-pad Operator s Manual Edition 1 Notice i-pad Operator s Manual CU Medical Systems, Inc. reserves the right to make changes on the device specifications contained in this manual at any time without prior notice or obligation

More information

INTRODUCTION. 4 SAFETY INSTRUCTIONS. 5 ABOUT THIS DEVICE. 6 FIRST OPERATION. 7 THE DISPLAY. 8 ATTACHING THE WRIST SLEEVE. 9 CORRECT MEASUREMENT.

INTRODUCTION. 4 SAFETY INSTRUCTIONS. 5 ABOUT THIS DEVICE. 6 FIRST OPERATION. 7 THE DISPLAY. 8 ATTACHING THE WRIST SLEEVE. 9 CORRECT MEASUREMENT. Table of contents INTRODUCTION.............................. 4 SAFETY INSTRUCTIONS........................ 5 ABOUT THIS DEVICE.......................... 6 FIRST OPERATION............................ 7

More information

User Instruction Computer Assisted Local Analgesia. 337 Marion, Le Gardeur QC, Canada, J5Z 4W8

User Instruction Computer Assisted Local Analgesia. 337 Marion, Le Gardeur QC, Canada, J5Z 4W8 User Instruction Computer Assisted Local Analgesia 1-800-667-9622 337 Marion, Le Gardeur QC, Canada, J5Z 4W8 USER INSTRUCTION Congratulations on your new CALAJECT! Please read these instructions thoroughly

More information

USER MANUAL M-200. Please take time to read these instructions before starting to use the scale. Version /06

USER MANUAL M-200. Please take time to read these instructions before starting to use the scale. Version /06 USER MANUAL M-200 Please take time to read these instructions before starting to use the scale Version 1.0 07/06 Contents Introduction 3 Product Specification 3 Safety Instructions 4 Explanation of Graphic

More information

VN415/VO425 Specifications

VN415/VO425 Specifications VN415/VO425 Specifications Item No. 8105231-1 01/2014 Contents VN415 Specifications... 1 1.1 Technical Standards:...1 1.2 System Requirements:...1 1.3 Included and Optional Parts...2 VO425 Specifications...

More information

Nursing Beds with Dewert drive system

Nursing Beds with Dewert drive system Nursing Beds with Dewert drive system GB Casa Med Classic 4 / Classic (FS) Casa Med Ultra / Ultra (FS) Casa Med Classic Low Casa Med Classic (FS) 4 / Classic / Casa FS Med / Casa Classic Med Low Ultra

More information

PHYSIOFLOW Q-LINK TM

PHYSIOFLOW Q-LINK TM PHYSIOFLOW Q-LINK TM Service Manual Thursday, 20 October 2016 First placing on the market : 18 January 2012 User Manual PhysioFlow Q-Link 1/17 Table of contents 1. General Information... 3 About this manual...

More information

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06 OtoRead - Technical Specifications Page 0 Technical Specifications OtoRead D-0116698-A 2017/06 OtoRead - Technical Specifications Page 1 OtoRead TM Configuration Overview The OtoReadTM is available in

More information

Not for print. Microphone Test Device with SONNET MTD Adapter. User Manual. Cochlear Implants NOT FOR PRINT

Not for print. Microphone Test Device with SONNET MTD Adapter. User Manual. Cochlear Implants NOT FOR PRINT Cochlear Implants Microphone Test Device with SONNET MTD Adapter User Manual AW32690_1.0 (English) Table of contents 1. Table of contents 2. INTRODUCTION 3 Product description 3 3. INTENDED USE INDICATIONS

More information

MedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11

MedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11 INSTALLATION MANUAL 2 Contents Getting To Know Your AVANT POLAR HIT TM... 4 Setting up the System... 6 Software Installation... 7 Driver Installation Windows 7... 10 Driver Installation Windows XP... 13

More information

Technical Data. Electrocardiograph ECG-1250K TD.ECG1250_L. This technical data may be revised or replaced by Nihon Kohden at any time without notice.

Technical Data. Electrocardiograph ECG-1250K TD.ECG1250_L. This technical data may be revised or replaced by Nihon Kohden at any time without notice. Technical Data Electrocardiograph ECG-1250K This technical data may be revised or replaced by Nihon Kohden at any time without notice. TD.ECG1250_L Specifications ECG input Input impedance: 20 MΩ Electrode

More information

DENTAL X-RAY OPERATOR'S INSTRUCTIONS. (for USA) Wall Mount Type...WK

DENTAL X-RAY OPERATOR'S INSTRUCTIONS. (for USA) Wall Mount Type...WK M 505 DENTAL X-RAY OPERATOR'S INSTRUCTIONS (for USA) Wall Mount Type...WK WARNING This X-ray equipment may be dangerous to patient and operator unless safe exposure factors, operating instructions and

More information

The following symbol indicates that the device is MR-unsafe:

The following symbol indicates that the device is MR-unsafe: The following symbol indicates that the device is MR-unsafe: MR Unsafe Do not use this equipment In the MRI scan room Patient must follow the doctor s instructions and should not perform a self-assessment

More information

M-400 M-410 M-420 M-430

M-400 M-410 M-420 M-430 USER MANUAL M-400 M-410 M-420 M-430 Please take time to read these instructions before starting to use the scale Version 1.1 10/17 Contents Introduction 3 Product Specification 3 Safety Instructions 4

More information

: 0089 GTIN

: 0089 GTIN GTIN: 00894912002050 PRECAUTIONS PROBE Non-invasive probes are for transcutaneous use only Probe transducer tips are thin and delicate. Be careful not to drop or hit the probe tip. After use, protect the

More information

Exergen TAT 5000S RS232 TTL Supplemental Instructions for Use

Exergen TAT 5000S RS232 TTL Supplemental Instructions for Use www.exergen.com/s Exergen TAT 5000S RS232 TTL Supplemental Instructions for Use For additional specifications, see GE Healthcare CARESCAPE V100 Vital Signs Monitor Operator's Manual, Section 12. Symbol

More information

JPD-FR302. User Manual. Infrared Thermometer

JPD-FR302. User Manual. Infrared Thermometer JPD-FR302 User Manual Infrared Thermometer User Instructions For proper use of the product, please read this manual before using the product, and follow this manual when operating the product. Before using

More information

DIGITAL BLUETOOTH THEROMETER PBT

DIGITAL BLUETOOTH THEROMETER PBT DIGITAL BLUETOOTH THEROMETER PBT Index 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Introduction Important Information Before Use Product Identification Description of LCD Display Battery Installation

More information

#

# INSTALLATION MANUAL 2 Contents Getting To Know Your AVANT POLAR HIT TM... 4 Setting up the System... 6 Software Installation... 7 Driver Installation Windows 7... 10 Driver Installation Windows XP... 13

More information

SAVI SCOUT Surgical Guidance System. Console Operation Manual

SAVI SCOUT Surgical Guidance System. Console Operation Manual SAVI SCOUT Surgical Guidance System Console Operation Manual 2 Copyrights and Trademarks 2016 Cianna Medical, Inc. All rights reserved. Patents pending. Cianna Medical and SAVI are registered trademarks

More information

Operator s Manual External Remote Controller (ERC)

Operator s Manual External Remote Controller (ERC) OM0000-C, 2010-07 Page 1 of 25 Table of Contents 1. SYMBOLS DEFINITION:...3 2. PRODUCT WARNINGS:...6 3. PRODUCT DESCRIPTION:...8 4. COMPONENT IDENTIFICATION:...8 5. INSTRUCTIONS FOR USE:...9 6. EMERGENCY

More information

CONTACTLESS THERMOMETER Thermo Checker

CONTACTLESS THERMOMETER Thermo Checker User's Manual for model DT-060 Infrared forehead Thermometer CONTACTLESS THERMOMETER Thermo Checker The Infopia DT-060(Thermo Checker ) non-contact thermometer features the advanced technology to measure

More information

INSTALLATION MANUAL AVANT HIT+ Hearing Instrument Test Chamber.

INSTALLATION MANUAL AVANT HIT+ Hearing Instrument Test Chamber. INSTALLATION MANUAL AVANT Hearing Instrument Test Chamber HIT+ www.medrx-int.com Contents Getting To Know Your AVANT HIT+. 3 Computer Requirements 4 Setup System. 5 Software Installation.. 6 Sound Card

More information

H2 Check Operating Manual

H2 Check Operating Manual H2 Check Operating Manual Federal (USA) law restricts this device to sale by or on the order of a physician or licensed practitioner. Micro Direct, Inc. 803 Webster Street Lewiston, ME 04240 1-800-588-3381

More information

WRIST BLOOD PRESSURE MONITOR

WRIST BLOOD PRESSURE MONITOR WRIST BLOOD PRESSURE MONITOR Instruction Manual MODEL: ABP801 www.accumed.com TABLE OF CONTENTS INTRODUCTION... 1 NOTES ON SAFETY... 1 ABOUT BLOOD PRESSURE... 3 PRECAUTIONS BEFORE US... 4 FEATURES OF THE

More information

Osmolarity System USER MANUAL FOR QUANTITATIVE MEASUREMENT OF OSMOLARITY OF OCULAR TISSUES. osdcare.com

Osmolarity System USER MANUAL FOR QUANTITATIVE MEASUREMENT OF OSMOLARITY OF OCULAR TISSUES. osdcare.com Osmolarity System FOR QUANTITATIVE MEASUREMENT OF OSMOLARITY OF OCULAR TISSUES USER MANUAL osdcare.com I-PEN User Guide I-PEN User Guide TABLE OF CONTENTS I-PEN I-PEN is a trademark of I-MED Pharma Inc.

More information

The following languages can be found on our website: French. German. Spanish. Italian. Swedish. Portuguese. Russian. Dutch.

The following languages can be found on our website:   French. German. Spanish. Italian. Swedish. Portuguese. Russian. Dutch. Manufactured By: 5580 S. Nogales Hwy. Tucson, Az 85706 USA Telephone: 800-975-7987 Fax: 520-294-6061 www.westmedinc.com PN 74586, Rev. 10 MT Promedt Consulting GmbH Altenhofstr. 80 66386 St. Ingbert, Germany

More information

Transcutaneous Electrical Nerve Stimulator

Transcutaneous Electrical Nerve Stimulator Transcutaneous Electrical Nerve Stimulator Simple, effective pain relief *For the temporary relief of pain as part of current medication programme. Distributor Medi-Direct International Ltd. Unit 24, Wilford

More information

ENGLISH. Important safety information Read this important information carefully before you use the device and save it for future reference.

ENGLISH. Important safety information Read this important information carefully before you use the device and save it for future reference. SCH740 EN www.philips.com/avent Philips Consumer Lifestyle BV Tussendiepen 4, 9206 AD Drachten, Netherlands Trademarks owned by the Philips Group. 2017 Koninklijke Philips N.V. All rights reserved Find

More information

Non-contact Forehead IR Thermometer

Non-contact Forehead IR Thermometer User s Manual Non-contact Forehead IR Thermometer Model IR200 Introduction Congratulations on your purchase of the Model IR200 IR Thermometer. This thermometer is intended for scanning groups of individuals

More information

2015 Koninklijke Philips N.V. All rights reserved Philips Consumer Lifestyle BV Tussendiepen 4, 9206AD Drachten, Netherlands

2015 Koninklijke Philips N.V. All rights reserved Philips Consumer Lifestyle BV Tussendiepen 4, 9206AD Drachten, Netherlands SCH740 2015 Koninklijke Philips N.V. All rights reserved Philips Consumer Lifestyle BV Tussendiepen 4, 9206AD Drachten, Netherlands 4213.354.3816.3 (11/2015) >75% recycled paper >75% papier recyclé 2 3

More information

Rotating Anode X-Ray Tube Housing Assembly. General Data

Rotating Anode X-Ray Tube Housing Assembly. General Data Technical Data TD ROTANODE E7252X E7252FX E7252GX 0197 Rotating Anode X-Ray Tube Housing Assembly High speed rotating anode X-ray tube housing assembly for high energy radiographic and cine-fluoroscopic

More information

INSTRUCTIONS FOR YOUR NEW PLASMAFLOW. Vascular Therapy System (Compressible Limb Sleeve Device)

INSTRUCTIONS FOR YOUR NEW PLASMAFLOW. Vascular Therapy System (Compressible Limb Sleeve Device) INSTRUCTIONS FOR YOUR NEW PLASMAFLOW Vascular Therapy System (Compressible Limb Sleeve Device) Customer Service Toll Free: 888-508-0712 Email: CustomerService@manamed.net Web: www.manamed.net 1511 W. Alton

More information

GTIN:

GTIN: GTIN: 00894912002920 TABLE OF CONTENTS Introduction...1 Features...1 Indications for Use...1 Contraindications...1 Warnings & Precautions...2 Controls...3 Operation...4 Recharging the Battery...5 Replacing

More information

By Paul Aylett at 12:08 pm, Apr 13, 2016

By Paul Aylett at 12:08 pm, Apr 13, 2016 TD2 Series Content Introduction Parts Features General Warnings and Safety Using your TENS Pain Reliever Troubleshooting Positions for use Specification Compatibility EMC Maintenance and Cautions Explanation

More information

User Manual. Glass Body Fat Analyzer LS203-B. version:1.0

User Manual. Glass Body Fat Analyzer LS203-B. version:1.0 version:1.0 User Manual Glass Body Fat Analyzer LS203-B Contains FCC ID: OU9AW8001-LS GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD Zone A, 5/F., Investment Building, No. 12, Huizhan East Rd., Torch

More information

#0086.

#0086. INSTALLATION MANUAL Contents Getting to Know Your AVANT REM Speech+... 3 Software Installation... 4 Driver Installation Windows 7... 7 EMC Precautions... 11 Safety... 15 Limited Warranty... 18 #0086 www.medrx-usa.com

More information

Ceiling Model Ceiling Model for LEDview Plus and Heliodent Plus. Installation Requirements. New as of: English

Ceiling Model Ceiling Model for LEDview Plus and Heliodent Plus. Installation Requirements. New as of: English New as of: 03.2017 Ceiling Model Ceiling Model for LEDview Plus and Heliodent Plus Installation Requirements English Installation Requirements Ceiling Version = Dentsply Sirona Installation Requirements

More information

EICKEMEYER INFUSION WARMER

EICKEMEYER INFUSION WARMER EICKEMEYER INFUSION WARMER MANUAL Art. No. 402091 TELEPHONE +49 7461 96580 0 www.eickemeyer.com Contents 1 Introduction... 3 2 Working Principle... 3 3 Main Technical Specifications... 3 4 Composition

More information

`bob`=p=^åèìáëáíáçå=råáí

`bob`=p=^åèìáëáíáçå=råáí `bob`=p=^åèìáëáíáçå=råáí qéåüåáå~ä=a~í~= båöäáëü The new CEREC 3 generation for the computer-aided manufacture of ceramic restorations. CAD system for making high-precision optical impressions in the mouth.

More information

BodyclockStimplusManual.qx8_Layout 1 17/08/ :53 Page 1. Body Clock Stimplus. Instructions for use

BodyclockStimplusManual.qx8_Layout 1 17/08/ :53 Page 1. Body Clock Stimplus. Instructions for use BodyclockStimplusManual.qx8_Layout 1 17/08/2012 11:53 Page 1 Body Clock Stimplus TM Instructions for use BodyclockStimplusManual.qx8_Layout 1 17/08/2012 11:53 Page 2 Acupuncture is an ancient Chinese therapy

More information

OPERATOR S MANUAL AN APPLIED DIGITAL COMPANY

OPERATOR S MANUAL AN APPLIED DIGITAL COMPANY OPERATOR S MANUAL AN APPLIED DIGITAL COMPANY Contents: VeriChip H2 Reader Assembly Part Number 600-000515-000 (includes all of the following): USER INSTRUCTIONS Description Part Number Description The

More information

SJM MRI Activator. Handheld Device. User's Manual. Model EX4000

SJM MRI Activator. Handheld Device. User's Manual. Model EX4000 SJM MRI Activator Handheld Device User's Manual Model EX4000 Unless otherwise noted, indicates that the name is a trademark of, or licensed to, St. Jude Medical or one of its subsidiaries. ST. JUDE MEDICAL

More information

AUTOMATIC BLOOD PRESSURE MONITOR (Arm Cuff Type) INSTRUCTION MANUAL

AUTOMATIC BLOOD PRESSURE MONITOR (Arm Cuff Type) INSTRUCTION MANUAL AUTOMATIC BLOOD PRESSURE MONITOR (Arm Cuff Type) INSTRUCTION MANUAL Model: SPBP-04 English Instruction Guide Thank you for choosing Advocate as your monitor of choice. The first, most important part of

More information

Multi-Control Panel for built-in system. Multi Pad for NLX / imd OPERATION MANUAL OM-E0538E 001

Multi-Control Panel for built-in system. Multi Pad for NLX / imd OPERATION MANUAL OM-E0538E 001 Multi-Control Panel for built-in system Multi Pad for NLX / imd OPERATION MANUAL OM-E0538E 001 Thank you for purchasing Multi Pad. Read this Operation Manual carefully before use for operation instructions

More information

POCKET AIR. Portable Nebulizer. Instruction Manual MBPN002 / MB / MB05006

POCKET AIR. Portable Nebulizer. Instruction Manual MBPN002 / MB / MB05006 R POCKET AIR Portable Nebulizer Instruction Manual MBPN002 / MB0500300/ MB05006 Table of Contents General information... 1 Intended Use... 2 Safety Precautions... 3 Explanation of Symbols... 4 Package

More information

`bob`=p=^åèìáëáíáçå=råáí=bma

`bob`=p=^åèìáëáíáçå=råáí=bma `bob`=p=^åèìáëáíáçå=råáí=bma qéåüåáå~ä=a~í~= båöäáëü The new CEREC 3 generation for the computer-aided manufacture of ceramic restorations. CAD system for making high-precision optical impressions in the

More information

ENG en. Operating instructions. Iris Magneton MF Wellness therapy

ENG en. Operating instructions. Iris Magneton MF Wellness therapy ENG en Operating instructions Iris Magneton MF Wellness therapy Edition 09 / 2012 These operating instructions constitute an accessory of the device. They must therefore be kept in a suitable place near

More information

USER S MANUAL Volk Pictor Plus Fluorescein Angiography (FA) Module For Use with: Volk Pictor Plus

USER S MANUAL Volk Pictor Plus Fluorescein Angiography (FA) Module For Use with: Volk Pictor Plus USER S MANUAL Volk Pictor Plus Fluorescein Angiography (FA) Module For Use with: Volk Pictor Plus IM-080 Rev. A Page 1 of 16 THIS SALES PACKAGE INCLUDES: Model: Fluorescein Angiography (VP2FA) IM-080 Description:

More information

OPERATOR'S INSTRUCTIONS DX-073 DENTAL X-RAY

OPERATOR'S INSTRUCTIONS DX-073 DENTAL X-RAY DENTAL X-RAY DX-073 Wall Mount Type...WK Ceiling Mount Type...CK Floor Mount Type...FK1/2 Mobil Mount Type...FM Room Mount Type...RKII OPERATOR'S INSTRUCTIONS 0197 WARNING : This X-ray equipment may be

More information

Operation Guide Model: 405-HT V3.0

Operation Guide Model: 405-HT V3.0 MODEL 405-HT Operation Guide Model: 405-HT V3.0 Fully Automatic Wrist Cuff Blood Pressure Monitor (ELECTRONIC SPHYGMOMANOMETER) OPERATION GUIDE INDEX IMPORTANT INFORMATION... 2 CONTENTS AND DISPLAY INDICATORS...

More information

Pain Management System

Pain Management System TM Pain Management System Model: ireliev Model #: ET-1313 Operating & Instruction Manual Read Before Using ireliev Pain Management System Intended Use The ireliev Pain Management System (Model # ET-1313)

More information

Welch Allyn Home Scale (T- RPM-SCALE100)

Welch Allyn Home Scale (T- RPM-SCALE100) Welch Allyn Home Scale (T- RPM-SCALE100) Directions for use 901077 Weight scale, Software Version 1.0 2017 Welch Allyn. All rights are reserved. To support the intended use of the product described in

More information

EXERGEN. English. TemporalScanner. Accurate Temperature with a Gentle Forehead Scan. Four Reasons to Standardize with Exergen Thermometers

EXERGEN. English. TemporalScanner. Accurate Temperature with a Gentle Forehead Scan. Four Reasons to Standardize with Exergen Thermometers EXERGEN TemporalScanner Accurate Temperature with a Gentle Forehead Scan Four Reasons to Standardize with Exergen Thermometers 1. More than 70 published studies supporting accuracy from preemies to geriatrics,

More information

User Manual. Before Using Your WiTouch Pro Device

User Manual. Before Using Your WiTouch Pro Device User Manual Before Using Your WiTouch Pro Device Sync the Remote Control and the WiTouch Pro Device. Using the provided screwdriver, remove the back cover from the WiTouch Pro device. 2. Remove the clear

More information

IEC Second Edition

IEC Second Edition Electromagnetic Compatibility of Medical Electrical Equipment Second Edition Prepared by Mr. James Conrad Presented by Dr. William A. Radasky 1 Second Edition Updates first edition on standards developed

More information

OPERATOR S INSTRUCTIONS (for USA & Canada)

OPERATOR S INSTRUCTIONS (for USA & Canada) MODEL 097 DENTAL X-RAY OPERATOR S INSTRUCTIONS (for USA & Canada) WARNING This X-ray equipment may be dangerous to patients and operators unless safe exposure factors and operating instructions are observed.

More information

OPERATOR'S INSTRUCTIONS DENTAL X-RAY MODEL 096

OPERATOR'S INSTRUCTIONS DENTAL X-RAY MODEL 096 DENTAL X-RAY MODEL 096 OPERATOR'S INSTRUCTIONS 0197 WARNING: This X-ray equipment may be dangerous to patients and operators unless safe exposure factors and operating instructions are observed. R Table

More information

MINISCAV Vacuum Pump Manual

MINISCAV Vacuum Pump Manual MINISCAV Vacuum Pump Manual North American Model Caution: Federal law restricts this device to sale by or on the order of a physician or dentist. MR Unsafe - Do not place or use Miniscav in or near an

More information

Wireless TENS Pain Reliever. WT1 Series

Wireless TENS Pain Reliever. WT1 Series Wireless TENS Pain Reliever WT1 Series Content Introduction Parts Features General Warnings and Safety Using your Wireless TENS Pain Reliever Troubleshooting Positions for use Mode Selection Specification

More information

Central Blood Pressure Meter Model cbp301. Operating Manual

Central Blood Pressure Meter Model cbp301. Operating Manual Central Blood Pressure Meter Model cbp301 Operating Manual Document cbp301-009 Issue 4 September 2011 Contents Introduction... 3 Package Contents... 5 Warnings and Cautions... 6 Contraindications... 7

More information

Relief. At Last. User Manual For an effective treatment, read the entire User Manual before using Kyrobak.

Relief. At Last. User Manual For an effective treatment, read the entire User Manual before using Kyrobak. Relief. At Last. User Manual For an effective treatment, read the entire User Manual before using Kyrobak. Contents Know Your Kyrobak 2 Safety Instructions 3 Before You Start 4 How to Use Kyrobak 5 Operating

More information

HD STETH TM Quick Start User Guide

HD STETH TM Quick Start User Guide Thank you and for choosing the futuristic HD Steth TM manufactured by HD Medical Inc. USA Indications for Use (IFU) HD Steth is an electronic stethoscope meant to assist a qualified clinician to capture,

More information

SE: Bruksanvisning GB: User Guide ES: Instrucciones DE: Gebrauchsanweisung IT: Istruzioni per l uso FR: Consignes d utilisation.

SE: Bruksanvisning GB: User Guide ES: Instrucciones DE: Gebrauchsanweisung IT: Istruzioni per l uso FR: Consignes d utilisation. SE: Bruksanvisning GB: User Guide ES: Instrucciones DE: Gebrauchsanweisung IT: Istruzioni per l uso FR: Consignes d utilisation active Svenska... 3 English... 9 Español... 15 Deutsch... 21 Italiano...

More information

TEST REPORT... 1 CONTENT...

TEST REPORT... 1 CONTENT... CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2

More information

Model: &

Model: & 600A True RMS Digital Clamp Meter Model: 72-3097 & 72-3099 1 CONTENTS Page Number Details 3 Important Safety Information 4 Product overview 4 Key Functions 5 General Specification 5 Electrical Specification

More information

AliveCor Heart Monitor. User Manual. AliveECG Mobile App for Android

AliveCor Heart Monitor. User Manual. AliveECG Mobile App for Android AliveCor Heart Monitor User Manual AliveECG Mobile App for Android NOTE: For the current information on your product please visit www.alivecor.com/manuals 2011-2013 AliveCor, Inc. All rights reserved.

More information

Product Name: COMPER SMART DOPPLER FETAL MONITOR. Product Model: DFMX

Product Name: COMPER SMART DOPPLER FETAL MONITOR. Product Model: DFMX DFMX User Manual Document Num: History of Change: User Manual JS02114DFMX V1.0 Issue Date: Version: Editor: Reviewer: Approver: Date:xx-xx-xx Date:xx-xx-xx Date:xx-xx-xx Product Name: COMPER SMART DOPPLER

More information

User Manual. Use, Maintenance and Service of the. Sinuscan 301

User Manual. Use, Maintenance and Service of the. Sinuscan 301 User Manual Use, Maintenance and Service of the Sinuscan 301 Copyright 2018 Mediq Suomi Oy. All rights reserved. Reproduction, transfer, distribution or storage, in whole or in part, of this document in

More information

Product Manual N.2 WEARABLE ECG. PRODUCT MANUAL

Product Manual N.2 WEARABLE ECG.   PRODUCT MANUAL Product Manual WEARABLE ECG www.vitaljacket.com www.biodevices.pt Biodevices S.A. Av. D. Afonso Henriques, 1462 1º Traseiras 4450-013 Matosinhos Portugal N.2 O NOVO NORTE PROGRAMA OPERACIONAL REGIONAL

More information

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation Annex to declaration accreditation (scope accreditation) Locations where activities are performed under accreditation Location Abbreviation/ location code Head Location Vijzelmolenlaan 5 & 7 3447 GX oerden

More information

ibed Locator Model 5212

ibed Locator Model 5212 ibed Locator Model 5212 Connected Hospital Instructions for Use and Installation For Parts or Technical Assistance: USA: 1-800-327-0770 2011/03 5212-009-101 REV C www.stryker.com Table of Contents Symbols

More information

This product may malfunction due to electromagnetic waves caused by portable

This product may malfunction due to electromagnetic waves caused by portable 1 IMPORTANT NOTICE This product may malfunction due to electromagnetic waves caused by portable personal telephones, transceivers, radio-controlled toys, etc. Be sure to avoid having objects such as, which

More information

Non-contact Forehead IR Thermometer

Non-contact Forehead IR Thermometer User s Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Non-contact Forehead IR Thermometer Model IR200 Introduction Congratulations

More information

CardioMessenger II-S Transmitter for BIOTRONIK Home Monitoring. Technical Manual

CardioMessenger II-S Transmitter for BIOTRONIK Home Monitoring. Technical Manual CardioMessenger II-S Transmitter for BIOTRONIK Home Monitoring 362454_D_GA_CM_II-S_US.indd 1 Technical Manual 17.04.08 16:28:16 by BIOTRONIK GmbH & Co. KG All rights reserved. Specifications subject to

More information

TM Machine WetAlert TM Wireless Wetness Detector In-center User s Guide

TM Machine WetAlert TM Wireless Wetness Detector In-center User s Guide 2008K@home TM Machine WetAlert TM Wireless Wetness Detector In-center User s Guide 2008K@home WetAlert Wireless Wetness Detector In-Center User s Guide Copyright 2012-2014, 2016, Fresenius USA, Inc. All

More information

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China 4317137.50 EMC Test report for LED Fixed luminaires Models LED12036-1R, LED12036-2TU, LED120363R, LED12036-4TU2, LED12036-6TR, LED12036-1R CHR, LED12036-2TU CHR, LED12036-3R CHR, LED12036-4TU2 CHR, LED12036-6TR

More information

Compressor Nebulizer. Model No: 9R-021 series. Please read the instruction manual before use.

Compressor Nebulizer. Model No: 9R-021 series. Please read the instruction manual before use. Compressor Nebulizer Model No: 9R-021 series Please read the instruction manual before use. IMPORTANT SAFEGUARDS...... 1 1. INTRODUCTION... 6 2. PRODUCT DESCRIPTION... 7 3. OPERATION... 8 4. CLEANING...

More information

MS2109A AC/DC Clamp Meter. User Manual. Contents

MS2109A AC/DC Clamp Meter. User Manual. Contents MS2109A AC/DC Clamp Meter User Manual Contents 1. Safety information 1 1.1 Preparation 1 1.2 Usage 1 1.3 Signs and Labels 2 1.4 Maintenance 2 2. Description 2 2.1 Part name 3 2.2 Switch and button description

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Location(s) where activities are performed under accreditation Head Office Vijzelmolenlaan 5 & 7 3447 GX oerden The Netherlands Location Abbreviation/ location code Vijzelmolenlaan 5 & 7 3447 GX oerden

More information

EMC Test report for LED Panel Light Models , , , , ,

EMC Test report for LED Panel Light Models , , , , , 4326247.50 EMC Test report for LED Panel Light Models 000529, 000530, 000531, 000532, 000535, 000536 Guangzhou, date of issue: 2016-02-24 Author:Jazz Liang By order of Marvo Verlichting B.V. at Hoogeveen,

More information

Draft. User s Manual. Transmitter Model EX1150

Draft. User s Manual. Transmitter Model EX1150 User s Manual Merlin @home Transmitter Model EX1150 CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 2008 St. Jude Medical Cardiac Rhythm Management Division.

More information

User Manual InfraRed Thermometer With Laser Pointer and High/Low Alarms Model IR270

User Manual InfraRed Thermometer With Laser Pointer and High/Low Alarms Model IR270 User Manual InfraRed Thermometer With Laser Pointer and High/Low Alarms Model IR270 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech IR270

More information

How to use the Barcode Scanner:

How to use the Barcode Scanner: How to use the Barcode Scanner: Please click on [TwMCA-App] icon shown on Desktop. Then click it to execute Barcode scanner software. Then select [Decode ON] button on the application software to turn

More information

Body Clock Stimplus Pro

Body Clock Stimplus Pro Body Clock Stimplus Pro TM Instructions for use Acupuncture is an ancient Chinese therapy in which specific points on the body, known as acupuncture points (acupoints) are stimulated by the use of needles.

More information

EMC Test Report. Report Number: M030826

EMC Test Report. Report Number: M030826 Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report

More information