Nursing Beds with Dewert drive system
|
|
- Patrick Short
- 6 years ago
- Views:
Transcription
1 Nursing Beds with Dewert drive system GB Casa Med Classic 4 / Classic (FS) Casa Med Ultra / Ultra (FS) Casa Med Classic Low
2
3 Casa Med Classic (FS) 4 / Classic / Casa FS Med / Casa Classic Med Low Ultra / Casa / Casa Med Med Ultra Ultra (FS) FS / Casa Med Low GB 1 GB Table of Contents 1 Preface Introduction Information regarding this operating manual Symbols used in this operating manual Information regarding this operating manual Safety Safety information Safety information General Safety information Electrical fittings Safety information Nursing personnel, carers and users Safety information Nursing bed assembly Safety information Maintenance and inspection Safety devices/guards Safety devices/guards Control unit Safety devices Head/backrest adjustment emergency unlocking Safety measures Safety measures Limitations of use Safety measures Gap dimensions and bed rail spacing A Safety Measures Mattress Selection Safety measures Locking (disabling) the handset Intended use Delivery scope Transport and storage system Delivery scope List Assembly/set-up, dismantling, storage Nursing bed Installation site Nursing bed Designation of components Nursing bed Assembly/set-up Fitting the mattress support Fitting the actuator motors Connecting the handset and actuator motor for the foot section Fitting the bed ends (headboard and footboard) Connecting the bed end actuator motors All control unit connections at a glance Fitting the patient lifting pole Routing the mains cable Rechargeable battery (option) Rechargeable battery General information Rechargeable battery Charging Rechargeable battery Fitting Performing a function test Nursing bed Dismantling Nursing bed Storage with the transport and storage system Handset Handset Information on the variants Handset IPROXX Handset with magnetic key Handset Unlocking (enabling) Handset Locking (disabling) Handset Nurse mode Handset with mechanical key Handset Lock-out mode Handset Nurse mode Handset Patient mode Handset Programming mode Programming the handset Operation Operation General information Operation Mains cable, mains plug, wall socket Operation Raising/lowering the lower leg support Raising the lower leg support Lowering the lower leg support Operation Wheel brakes Operation Moving the nursing bed Cleaning and disinfection Nursing bed Cleaning Nursing bed Disinfection Maintenance and inspection Maintenance Daily Maintenance Every six months Maintenance Safety inspections Testing intervals Safety inspections Mechanical components Safety inspections Electrical components Safety inspections Measurement in accordance with BGV A Trouble Shooting Reuse Disposal Appendix Technical data Technical data Nursing bed Technical data Drive system EMC Tables Name plate Name plate Nursing bed Accessories and options Spare parts Warranty information...33 GB
4 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
5 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
6 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
7 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low Days Healthcare nursing beds have been designed in accordance with DIN EN for continuous use by the disabled.
8 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
9 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
10 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
11 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
12 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
13 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
14 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
15 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
16 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
17 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
18 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
19 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
20 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
21 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
22 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
23 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
24 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low
25 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low Total weight: Classic FS
26 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low Atmospheric Pressure Range RATED operating altitude (a) m Normal barometric pressure kpa a A d d i t i o n a l I n f o r m a t i o n Electromagnetic compatibility (*IEC/EN ) Additional information intended to be used by the end-product manufacturer (See *IEC/EN ) Additional information intended to be used with DEWERT actuator system consists of DEWERT product(s), such as: Control Unit, e.g. MC10, MC11, MCL, MCL II Single Drive, e.g. MEGAMAT MCZ, DS10 The above described DEWERT system consists of DEWERT product(s) is/are hereinafter called PRODUCT. * Standard(s): IEC :2007 EN :2007 The standards (see above) hereinafter called IEC/EN Guidance and manufacturer s declaration Electromagnetic Emissions - (*IEC/EN , Table 1) * edition: see page 1 standard(s) 2 The PRODUCT is intended for use in the electromagnetic environment specified below. The customer or the user of the PRODUCT should assure that it is used in such an environment. 3 Emissions test 4 RF emissions CISPR 11 6 RF emissions CISPR 11 7 Harmonic emissions IEC Voltage fluctuations/ flicker emissions IEC Group 1 Class B Class A Complies The PRODUCT uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. The PRODUCT is suitable for use in all establishments, including domestic establishments and those directly connected to the public lowvoltage power supply network that supplies buildings used for domestic purposes.
27 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low Guidance and manufacturer s declaration Electromagnetic Immunity - (*IEC/EN , Table 2) * edition: see page 1 standard(s) The PRODUCT is intended for use in the electromagnetic environment specified below. The customer or the user of the PRODUCT should assure that it is used in such an environment. Immunity test IEC test level Electrostatic discharge (ESD) IEC Electrical fast transient/burst IEC Surge IEC ± 6 kv contact ± 6 kv contact ± 8 kv air ± 8 kv air ± 2 kv for power supply lines ± 2 kv ± 1 kv for input/output lines Not applicable ± 1 kv line(s) to line(s) ± 1 kv ± 2 kv line(s) to earth ± 2 kv Compliance level Electromagnetic environment guidance Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. Voltage dips, short interruptions and voltage variations on power supply input lines IEC <5% UT (>95% dip in UT) for 0,5 cycle 40% UT (60% dip in UT) for 5 cycles 70% UT (30% dip in UT) for 25 cycles <5% UT (>95% dip in UT) for 5 s <5% UT 40% UT 70% UT <5% UT Mains power quality should be that of a typical commercial or hospital environment. If the user of the PRODUCT requires continued operation during power mains interruptions, it is recommended that the PRODUCT be powered from an uninterruptible power supply or a battery. Power frequency (50/60 Hz) magnetic field IEC A/m 3 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. NOTE: UT is the a.c. mains voltage prior to application of the test level.
28 GB 26 Casa Med Classic 4 / Classic Casa FS / Casa Med Med Classic Ultra (FS) / Casa / Med Ultra Classic FS / Low Casa / Casa Med Low Med Ultra (FS) Guidance and manufacturer s declaration Electromagnetic Immunity - GB for life supporting equipment and systems (*IEC/EN , Table 3) * edition: see page 1 standard(s) The PRODUCT is intended for use in the electromagnetic environment specified below. The customer or the user of the PRODUCT should assure that it is used in such an environment. Immunity test IEC test level Compliance level Electromagnetic environment guidance Conducted RF IEC Vrms 150 khz to 80 MHz outside ISM bands a 10 Vrms 150 khz to 80 MHz in ISM bands a Portable and mobile RF communications equipment should be used no closer to any part of the PRODUCT, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance: 3 Vrms d = 1,2 (P) 1/2 10 Vrms d = 1,2 (P) 1/2 Radiated RF IEC V/m 80 MHz to 2,5 GHz 10 V/m d = 1,2 (P) 1/2 d = 2,3 (P) 1/2 80 MHz to 800 MHz 800 MHz to 2,5 GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). b Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey c, should be less than the compliance level in each frequency range d. Interference (from a mobile phone for example), may occur in the vicinity of equipment marked with the following symbol: NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a The ISM (industrial, scientific and medical) bands between 150 khz and 80 MHz are 6,765 MHz to 6,795 MHz; 13,553 MHz to 13,567 MHz; 26,957 MHz to 27,283 MHz; and 40,66 MHz to 40,70 MHz. b The compliance levels in the ISM frequency bands between 150 khz and 80 MHz and in the frequency range 80 MHz to 2,5 GHz are intended to decrease the likelihood that mobile/portable communications equipment could cause interference if it is inadvertently brought into patient areas. For this reason, an additional factor of 10/3 has been incorporated into the formulae used in calculating the recommended separation distance for transmitters in these frequency ranges. c Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the PRODUCT is used exceeds the applicable RF compliance level above, the PRODUCT should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the PRODUCT.. d Over the frequency range 150 khz to 80 MHz, field strengths should be less than 3 V/m.
29 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low Guidance and manufacturer s declaration Electromagnetic Immunity - (*IEC/EN , Table 2) * edition: see page 1 standard(s) The PRODUCT is intended for use in the electromagnetic environment specified below. The customer or the user of the PRODUCT should assure that it is used in such an environment. Immunity test IEC test level Electrostatic discharge (ESD) IEC Electrical fast transient/burst IEC Surge IEC ± 6 kv contact ± 6 kv contact ± 8 kv air ± 8 kv air ± 2 kv for power supply lines ± 2 kv ± 1 kv for input/output lines Not applicable ± 1 kv line(s) to line(s) ± 1 kv ± 2 kv line(s) to earth ± 2 kv Compliance level Electromagnetic environment guidance Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. Voltage dips, short interruptions and voltage variations on power supply input lines IEC <5% UT (>95% dip in UT) for 0,5 cycle 40% UT (60% dip in UT) for 5 cycles 70% UT (30% dip in UT) for 25 cycles <5% UT (>95% dip in UT) for 5 s <5% UT 40% UT 70% UT <5% UT Mains power quality should be that of a typical commercial or hospital environment. If the user of the PRODUCT requires continued operation during power mains interruptions, it is recommended that the PRODUCT be powered from an uninterruptible power supply or a battery. Power frequency (50/60 Hz) magnetic field IEC A/m 3 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. NOTE: UT is the a.c. mains voltage prior to application of the test level.
30 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low Guidance and manufacturer s declaration Recommended separation distances between portable and mobile RF communications equipment and the PRODUCT for life supporting equipment and systems (*IEC/EN , Table 5) * edition: see page 1 standard(s) The PRODUCT is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the PRODUCT can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the PRODUCT as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter [W] Separation distance (d) according to frequency of transmitter [m] 150 khz to 80 MHz outside ISM bands 150 khz to 80 MHz in ISM bands 80 MHz to 800 MHz 800 MHz to 2,5 GHz d = 1,2 (P) 1/2 d = 1,2 (P) 1/2 d = 1,2 (P) 1/2 d = 2,3 (P) 1/2 0,01 0,12 0,12 0,12 0,23 0,1 0,38 0,38 0,38 0,73 1 1,2 1,2 1,2 2,3 10 3,8 3,8 3,8 7, For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be determined using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2: The ISM (industrial, scientific and medical) bands between 150 khz and 80 MHz are 6,765 MHz to 6,795 MHz; 13,553 MHz to 13,567 MHz; 26,957 MHz to 27,283 MHz; and 40,66 MHz to 40,70 MHz. NOTE 3: An additional factor of 10/3 has been incorporated into the formulae used in calculating the recommended separation distance for transmitters in the ISM frequency bands between 150 khz and 80 MHz and in the frequency range 80 MHz to 2,5 GHz to decrease the likelihood that mobile/portable communications equipment could cause interference if it is inadvertently brought into patient areas. NOTE 4: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
31 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low Guidance and manufacturer s declaration Recommended separation distances between portable and mobile RF communications equipment and the PRODUCT for not life supporting equipment and systems (*IEC/EN , Table 6) * edition: see page 1 standard(s) The PRODUCT is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the PRODUCT can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the PRODUCT as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter [W] Separation distance (d) according to frequency of transmitter [m] 150 khz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2,5 GHz d = 1,2 (P) 1/2 d = 0,4 (P) 1/2 d = 0,7 (P) 1/2 0,01 0,12 0,04 0,1 0,1 0,38 0,13 0,22 1 1,2 0,4 0,7 10 3,8 1,3 2, For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
32 GB 30 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low A d d i t i o n a l I n f o r m a t i o n Electromagnetic compatibility (*IEC/EN ) Date: February 27, 2013 REV.: 00 Made by: W. Kracht Additional information intended to be used by the end-product manufacturer (See *IEC/EN ) Additional information intended to be used with DEWERT actuator system consists of DEWERT component(s)/product(s): Handset IPROXX The above described component(s)/product(s) is/are hereinafter called PRODUCT. NOTE: These instructions are only intended to be used by the end-product manufacturer. They should not be given to the operator of the end product. The factual information contained within may be used as a basis when creating the end-product manual. Observe the document Installation Instruction of PRODUCT (see above). * Standard(s): IEC :2007 EN :2007 The standards (see above) hereinafter called IEC/EN
33 Casa Med Classic 4 / Classic FS / Casa Med Ultra / Casa Med Ultra FS / Casa Med Low GB 31 Guidance and manufacturer s declaration Electromagnetic Immunity - for not life supporting equipment and systems (*IEC/EN , Table 4) * edition: see page 1 standard(s) The PRODUCT is intended for use in the electromagnetic environment specified below. The customer or the user of the PRODUCT should assure that it is used in such an environment. Immunity test IEC test level Compliance level Electromagnetic environment guidance Portable and mobile RF communications equipment should be used no closer to any part of the PRODUCT, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Conducted RF IEC Veff 150 khz to 80 MHz Recommended separation distance: 3 Veff d = 1,2 (P) 1/2 Radiated RF IEC V/m 80 MHz to 2500 MHz 10 V/m d = 0,4 (P) 1/2 80 MHz to 800 MHz d = 0,7 (P) 1/2 800 MHz to 2,5 GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b. Interference (from may a mobile occur phone in the for example), vicinity of may equipment occur in marked the vicinity with the of equipment following symbol: marked with the following symbol: NOTE 1: NOTE 2: At 80 MHz and 800 MHz, the higher frequency range applies. These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a b Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the PRODUCT is used exceeds the applicable RF compliance level above, the PRODUCTshould be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the PRODUCT. Over the frequency range 150 khz to 80 MHz, field strengths should be less than 3 V/m.
34 GB Casa Med Classic 4 / Classic Casa FS / Casa Med Med Classic Ultra (FS) / Casa / Med Ultra Classic FS / Low Casa / Casa Med Low Med Ultra (FS) GB 12.2 Name plate Name plate Nursing bed same data would apply to Casa Med Ultra, Ultra FS, Casa Med Classic Low. However name would change. The name plate is attached to the end of the nursing bed and indicates the following data: Protection class II (protective insulation) Protection class II (protective insulation) CE certification in accordance with 93/42/EEC Application Type B Applied part Part type B Type B Applied Part Protection Degree of Protection type (splash-proof) IP44 Degree of Protection IP44 Caution! Observe the operating manual Caution! Observe the operating manual Maximum continuous operation of the AB 2 min/ actuator Maximum motors continuous = 2 operation minutes of the AB 2 18 min/ min 18 actuator minutes motors minimum = 2 minutes pause 18 after minutes 18 min minimum pause after 2 minutes 2minutes Note on disposal On ME Equipment follow instructions Name plate for use. Patient lifting pole Name plate Patient lifting pole Name plate maximum patient weight & B safe working load A B C The name plate is attached to the mattress support A Name plate Detachable Parts of a medical bed of a mass of more Cthan 20 Kg The name plate is attached to the head and foot posts. The name plate is attached at the bottom of the patient lifting pole name and plate indicates Replacement the following Mattresses data: A Warning information about the max. weight bearing capacity of the patient lifting pole. Name plate is attached to the mattress support. B Article designation C Caution! Observe the operating manual Name plate maximum patient weight & safe working load GB The name plate is attached to the mattress support Name plate Detachable Parts of a medical bed of a mass of more than 20 Kg The name plate is attached to the head and foot posts name plate Replacement Mattresses Name plate is attached to the mattress support.
35 GB Casa Med Classic 4 / Classic Casa FS / Casa Med Med Classic Ultra (FS) / Casa / Med Ultra Classic FS / Low Casa / Casa Med Low Med Ultra (FS) Accessories and options Please contact your Days Healthcare specialist dealer (see dealer stamp on the back cover) to order any of the articles. GB Designation Order No. 9S Bed Rails Silver Casa Nuova, 9SL pair optional metal Transport and storage system Triangular hand grip with length adjustable belt GB 12.4 Spare parts Only use original spare parts from Days Healthcare. Note If you need any spare parts, please contact your Days Healthcare specialist dealer (see dealer stamp on back cover). 13 Warranty information The Days bed range carry s a 3 year warranty (Parts Only) from date of purchase. Important! During the warranty period any parts that have become defective due to faulty workmanship or material will be repaired or replaced without charge by Days Healthcare supplier / dealer. The warranty excludes all items that have been subject to undue wear and items subjected to misuse. Unauthorized changes or modifications will forfeit your warranty. If a defect or fault is discovered, the Days healthcare supplier / dealer from whom the electric bed was purchased should be notified immediately. Limitation of liability The warranty does not extend to the consequential costs resulting from fault clearance, in particular freight and travel costs, loss of earnings, expenses, etc. The manufacturer will not accept responsibility for any damage or injury caused by misuse or non-observance of the instructions set out in this user manual
36 Dealer Stamp
Powered Traction Unit OPERATION MANUAL
Powered Traction Unit OPERATION MANUAL CONTENTS Symbols Safety precautions Symbol for CAUTION Symbol for CONSULT INSTRUCTIONS FOR USE Symbol for SERIAL NUMBER Symbol for CATALOGUE NUMBER Symbol for AUTHORISED
More informationGuidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System
Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi TS ii ortable Tourniquet System Guidance and manufacturer s declaration electromagnetic emissions The TS ii ortable Tourniquet
More informationHeRO duet
HeRO duet CUSTOMER SERVICE TABLE OF CONTENTS TABLE OF CONTENTS OVERVIEW OVERVIEW OVERVIEW OVERVIEW USING HeRO duet USING HeRO duet USING HeRO duet Current HeRO Score HeRO USING HeRO duet USING HeRO duet
More informationBIODEX MULTI- JOINT SYSTEM
BIODEX MULTI- JOINT SYSTEM CONFORMANCE TO STANDARDS 850-000, 840-000, 852-000 FN: 18-139 5/18 Contact information Manufactured by: Biodex Medical Systems, Inc. 20 Ramsey Road, Shirley, New York, 11967-4704
More informationEnglish
English Specifications Type Power Source Vibration Frequency Maximum Output Power Consumption Water Pressure Lighting NE134 AC120V 50/60Hz AC230V 50/60Hz 28~32kHz 8W Max. 42VA 0.1~0.5MPa (1~5kgf/cm
More informationElectromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)
Compressor set Equipment Under Test (EUT) Type 028 Type 047 Type 052 Type 085 Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN 60601-1-2:2007 (IEC 60601-1-2:2007) 2017 PARI
More informationGeneral Safety/EMC and Electrical Information for i-limb ultra and i-limb digits
1. General Safety 1.1 The i-limb ultra and i-limb digits devices are electrical devices, which under certain circumstances could present an electrical shock hazard to the user. Please read the accompanying
More information(c) Medisave UK. Notice. Edition 1. i-pad Operator s Manual
Edition 1 Notice i-pad Operator s Manual CU Medical Systems, Inc. reserves the right to make changes on the device specifications contained in this manual at any time without prior notice or obligation
More informationTechnical Specifications Micromedical VisualEyes 505 by Interacoustics
VisualEyes 505 - Technical Specifications Page 0 Technical Specifications Micromedical VisualEyes 505 by Interacoustics D-0115523-B 2018/02 VisualEyes 505 - Technical Specifications Page 1 Included and
More informationUser Instruction Computer Assisted Local Analgesia. 337 Marion, Le Gardeur QC, Canada, J5Z 4W8
User Instruction Computer Assisted Local Analgesia 1-800-667-9622 337 Marion, Le Gardeur QC, Canada, J5Z 4W8 USER INSTRUCTION Congratulations on your new CALAJECT! Please read these instructions thoroughly
More informationD C 01/2019 3
D-0117968-C 01/2019 3 4 D-0117968-C 01/2019 Screw Driver Screw Driver Unplug both the Red & Blue connectors. (see above) Place a small flat head screw driver on the small orange tabs and push down while
More informationBiological Safety. Electromagnetic Compatibility (EMC) Observe the following precautions related to biological safety.
Biological Safety Observe the following precautions related to biological safety. WARNING: Non-medical (commercial) grade peripheral monitors have not been verified or validated by SonoSite as being suitable
More informationVN415/VO425 Specifications
VN415/VO425 Specifications Item No. 8105231-1 01/2014 Contents VN415 Specifications... 1 1.1 Technical Standards:...1 1.2 System Requirements:...1 1.3 Included and Optional Parts...2 VO425 Specifications...
More informationUSER MANUAL MHS-2500I. Please take time to read these instructions before starting to use the scale. Version /17
USER MANUAL MHS-2500I Please take time to read these instructions before starting to use the scale Version 1.0 05/17 Contents Introduction 3 Product Specification 3 Safety Instructions 4 Explanation of
More informationRolyan Splint Pan OPERATION MANUAL. Item # Small Item # Large
Rolyan Splint Pan OPERATION MANUAL Item #081544816 - Small Item #081544808 Large PLEASE READ THIS ENTIRE MANUAL BEFORE OPERATING YOUR NEW SPLINT PAN. Failure to follow these instructions could result in
More informationTH008F Multi-function Infrared Forehead Thermometer
TH008F Multi-function Infrared Forehead Thermometer Specifications Functions Temperature measurement range: Forehead mode: 34~42.2 C (93.2~108 F), Surface mode: -22~80 C (-7.6~176 F) Operating temperature
More informationOtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06
OtoRead - Technical Specifications Page 0 Technical Specifications OtoRead D-0116698-A 2017/06 OtoRead - Technical Specifications Page 1 OtoRead TM Configuration Overview The OtoReadTM is available in
More informationUSER MANUAL M-200. Please take time to read these instructions before starting to use the scale. Version /06
USER MANUAL M-200 Please take time to read these instructions before starting to use the scale Version 1.0 07/06 Contents Introduction 3 Product Specification 3 Safety Instructions 4 Explanation of Graphic
More informationTechnical Data. Electrocardiograph ECG-1250K TD.ECG1250_L. This technical data may be revised or replaced by Nihon Kohden at any time without notice.
Technical Data Electrocardiograph ECG-1250K This technical data may be revised or replaced by Nihon Kohden at any time without notice. TD.ECG1250_L Specifications ECG input Input impedance: 20 MΩ Electrode
More informationDENTAL X-RAY OPERATOR'S INSTRUCTIONS. (for USA) Wall Mount Type...WK
M 505 DENTAL X-RAY OPERATOR'S INSTRUCTIONS (for USA) Wall Mount Type...WK WARNING This X-ray equipment may be dangerous to patient and operator unless safe exposure factors, operating instructions and
More informationPHYSIOFLOW Q-LINK TM
PHYSIOFLOW Q-LINK TM Service Manual Thursday, 20 October 2016 First placing on the market : 18 January 2012 User Manual PhysioFlow Q-Link 1/17 Table of contents 1. General Information... 3 About this manual...
More informationMedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11
INSTALLATION MANUAL 2 Contents Getting To Know Your AVANT POLAR HIT TM... 4 Setting up the System... 6 Software Installation... 7 Driver Installation Windows 7... 10 Driver Installation Windows XP... 13
More informationINTRODUCTION. 4 SAFETY INSTRUCTIONS. 5 ABOUT THIS DEVICE. 6 FIRST OPERATION. 7 THE DISPLAY. 8 ATTACHING THE WRIST SLEEVE. 9 CORRECT MEASUREMENT.
Table of contents INTRODUCTION.............................. 4 SAFETY INSTRUCTIONS........................ 5 ABOUT THIS DEVICE.......................... 6 FIRST OPERATION............................ 7
More informationM-400 M-410 M-420 M-430
USER MANUAL M-400 M-410 M-420 M-430 Please take time to read these instructions before starting to use the scale Version 1.1 10/17 Contents Introduction 3 Product Specification 3 Safety Instructions 4
More information#
INSTALLATION MANUAL 2 Contents Getting To Know Your AVANT POLAR HIT TM... 4 Setting up the System... 6 Software Installation... 7 Driver Installation Windows 7... 10 Driver Installation Windows XP... 13
More informationNot for print. Microphone Test Device with SONNET MTD Adapter. User Manual. Cochlear Implants NOT FOR PRINT
Cochlear Implants Microphone Test Device with SONNET MTD Adapter User Manual AW32690_1.0 (English) Table of contents 1. Table of contents 2. INTRODUCTION 3 Product description 3 3. INTENDED USE INDICATIONS
More informationCeiling Model Ceiling Model for LEDview Plus and Heliodent Plus. Installation Requirements. New as of: English
New as of: 03.2017 Ceiling Model Ceiling Model for LEDview Plus and Heliodent Plus Installation Requirements English Installation Requirements Ceiling Version = Dentsply Sirona Installation Requirements
More informationOperating Manual Infrared thermometer
Operating Manual Infrared thermometer Model:IT-121 Professional Fast Accurate 1 CONTENTS 1 I n t r o d u c t i o n................ 3 1.1Product intended use 3 2 Basic principle 3 3 Pr o d u c t f e a t
More informationRotating Anode X-Ray Tube Housing Assembly. General Data
Technical Data TD ROTANODE E7252X E7252FX E7252GX 0197 Rotating Anode X-Ray Tube Housing Assembly High speed rotating anode X-ray tube housing assembly for high energy radiographic and cine-fluoroscopic
More informationINSTALLATION MANUAL AVANT HIT+ Hearing Instrument Test Chamber.
INSTALLATION MANUAL AVANT Hearing Instrument Test Chamber HIT+ www.medrx-int.com Contents Getting To Know Your AVANT HIT+. 3 Computer Requirements 4 Setup System. 5 Software Installation.. 6 Sound Card
More informationThe following symbol indicates that the device is MR-unsafe:
The following symbol indicates that the device is MR-unsafe: MR Unsafe Do not use this equipment In the MRI scan room Patient must follow the doctor s instructions and should not perform a self-assessment
More informationUSER S MANUAL Volk Pictor Plus Fluorescein Angiography (FA) Module For Use with: Volk Pictor Plus
USER S MANUAL Volk Pictor Plus Fluorescein Angiography (FA) Module For Use with: Volk Pictor Plus IM-080 Rev. A Page 1 of 16 THIS SALES PACKAGE INCLUDES: Model: Fluorescein Angiography (VP2FA) IM-080 Description:
More informationThe following languages can be found on our website: French. German. Spanish. Italian. Swedish. Portuguese. Russian. Dutch.
Manufactured By: 5580 S. Nogales Hwy. Tucson, Az 85706 USA Telephone: 800-975-7987 Fax: 520-294-6061 www.westmedinc.com PN 74586, Rev. 10 MT Promedt Consulting GmbH Altenhofstr. 80 66386 St. Ingbert, Germany
More informationSAVI SCOUT Surgical Guidance System. Console Operation Manual
SAVI SCOUT Surgical Guidance System Console Operation Manual 2 Copyrights and Trademarks 2016 Cianna Medical, Inc. All rights reserved. Patents pending. Cianna Medical and SAVI are registered trademarks
More informationGTIN:
GTIN: 00894912002920 TABLE OF CONTENTS Introduction...1 Features...1 Indications for Use...1 Contraindications...1 Warnings & Precautions...2 Controls...3 Operation...4 Recharging the Battery...5 Replacing
More informationWRIST BLOOD PRESSURE MONITOR
WRIST BLOOD PRESSURE MONITOR Instruction Manual MODEL: ABP801 www.accumed.com TABLE OF CONTENTS INTRODUCTION... 1 NOTES ON SAFETY... 1 ABOUT BLOOD PRESSURE... 3 PRECAUTIONS BEFORE US... 4 FEATURES OF THE
More informationENG en. Operating instructions. Iris Magneton MF Wellness therapy
ENG en Operating instructions Iris Magneton MF Wellness therapy Edition 09 / 2012 These operating instructions constitute an accessory of the device. They must therefore be kept in a suitable place near
More informationOperator s Manual External Remote Controller (ERC)
OM0000-C, 2010-07 Page 1 of 25 Table of Contents 1. SYMBOLS DEFINITION:...3 2. PRODUCT WARNINGS:...6 3. PRODUCT DESCRIPTION:...8 4. COMPONENT IDENTIFICATION:...8 5. INSTRUCTIONS FOR USE:...9 6. EMERGENCY
More information: 0089 GTIN
GTIN: 00894912002050 PRECAUTIONS PROBE Non-invasive probes are for transcutaneous use only Probe transducer tips are thin and delicate. Be careful not to drop or hit the probe tip. After use, protect the
More informationH2 Check Operating Manual
H2 Check Operating Manual Federal (USA) law restricts this device to sale by or on the order of a physician or licensed practitioner. Micro Direct, Inc. 803 Webster Street Lewiston, ME 04240 1-800-588-3381
More information#0086.
INSTALLATION MANUAL Contents Getting to Know Your AVANT REM Speech+... 3 Software Installation... 4 Driver Installation Windows 7... 7 EMC Precautions... 11 Safety... 15 Limited Warranty... 18 #0086 www.medrx-usa.com
More informationibed Locator Model 5212
ibed Locator Model 5212 Connected Hospital Instructions for Use and Installation For Parts or Technical Assistance: USA: 1-800-327-0770 2011/03 5212-009-101 REV C www.stryker.com Table of Contents Symbols
More informationINSTRUCTIONS FOR YOUR NEW PLASMAFLOW. Vascular Therapy System (Compressible Limb Sleeve Device)
INSTRUCTIONS FOR YOUR NEW PLASMAFLOW Vascular Therapy System (Compressible Limb Sleeve Device) Customer Service Toll Free: 888-508-0712 Email: CustomerService@manamed.net Web: www.manamed.net 1511 W. Alton
More informationPOCKET AIR. Portable Nebulizer. Instruction Manual MBPN002 / MB / MB05006
R POCKET AIR Portable Nebulizer Instruction Manual MBPN002 / MB0500300/ MB05006 Table of Contents General information... 1 Intended Use... 2 Safety Precautions... 3 Explanation of Symbols... 4 Package
More informationOPERATOR'S INSTRUCTIONS DX-073 DENTAL X-RAY
DENTAL X-RAY DX-073 Wall Mount Type...WK Ceiling Mount Type...CK Floor Mount Type...FK1/2 Mobil Mount Type...FM Room Mount Type...RKII OPERATOR'S INSTRUCTIONS 0197 WARNING : This X-ray equipment may be
More informationCentral Blood Pressure Meter Model cbp301. Operating Manual
Central Blood Pressure Meter Model cbp301 Operating Manual Document cbp301-009 Issue 4 September 2011 Contents Introduction... 3 Package Contents... 5 Warnings and Cautions... 6 Contraindications... 7
More informationIEC Second Edition
Electromagnetic Compatibility of Medical Electrical Equipment Second Edition Prepared by Mr. James Conrad Presented by Dr. William A. Radasky 1 Second Edition Updates first edition on standards developed
More informationMulti-Control Panel for built-in system. Multi Pad for NLX / imd OPERATION MANUAL OM-E0538E 001
Multi-Control Panel for built-in system Multi Pad for NLX / imd OPERATION MANUAL OM-E0538E 001 Thank you for purchasing Multi Pad. Read this Operation Manual carefully before use for operation instructions
More informationWelch Allyn Home Scale (T- RPM-SCALE100)
Welch Allyn Home Scale (T- RPM-SCALE100) Directions for use 901077 Weight scale, Software Version 1.0 2017 Welch Allyn. All rights are reserved. To support the intended use of the product described in
More informationTranscutaneous Electrical Nerve Stimulator
Transcutaneous Electrical Nerve Stimulator Simple, effective pain relief *For the temporary relief of pain as part of current medication programme. Distributor Medi-Direct International Ltd. Unit 24, Wilford
More informationL NKTEMP. Non-contact. Infrared Thermometer. User Manual LMP001
L NKTEMP Non-contact Infrared Thermometer User Manual LMP001 TABLE OF CONTENTS Product Description Intended Use Product Features Safety Precautions Using the Thermometer Taking a Measurement Temperature
More informationSPAC265-8W. AC-DC power supply module. Features. Description. Applications
AC-DC power supply module Datasheet production data Features Open frame switch mode power supply European input voltage range Single output 5 V, 8 W peak power, 4 W continuous operating mode EMC compliance
More informationHD STETH TM Quick Start User Guide
Thank you and for choosing the futuristic HD Steth TM manufactured by HD Medical Inc. USA Indications for Use (IFU) HD Steth is an electronic stethoscope meant to assist a qualified clinician to capture,
More information`bob`=p=^åèìáëáíáçå=råáí
`bob`=p=^åèìáëáíáçå=råáí qéåüåáå~ä=a~í~= båöäáëü The new CEREC 3 generation for the computer-aided manufacture of ceramic restorations. CAD system for making high-precision optical impressions in the mouth.
More information`bob`=p=^åèìáëáíáçå=råáí=bma
`bob`=p=^åèìáëáíáçå=råáí=bma qéåüåáå~ä=a~í~= båöäáëü The new CEREC 3 generation for the computer-aided manufacture of ceramic restorations. CAD system for making high-precision optical impressions in the
More informationEICKEMEYER INFUSION WARMER
EICKEMEYER INFUSION WARMER MANUAL Art. No. 402091 TELEPHONE +49 7461 96580 0 www.eickemeyer.com Contents 1 Introduction... 3 2 Working Principle... 3 3 Main Technical Specifications... 3 4 Composition
More informationOsmolarity System USER MANUAL FOR QUANTITATIVE MEASUREMENT OF OSMOLARITY OF OCULAR TISSUES. osdcare.com
Osmolarity System FOR QUANTITATIVE MEASUREMENT OF OSMOLARITY OF OCULAR TISSUES USER MANUAL osdcare.com I-PEN User Guide I-PEN User Guide TABLE OF CONTENTS I-PEN I-PEN is a trademark of I-MED Pharma Inc.
More informationOPERATOR S MANUAL AN APPLIED DIGITAL COMPANY
OPERATOR S MANUAL AN APPLIED DIGITAL COMPANY Contents: VeriChip H2 Reader Assembly Part Number 600-000515-000 (includes all of the following): USER INSTRUCTIONS Description Part Number Description The
More informationMINISCAV Vacuum Pump Manual
MINISCAV Vacuum Pump Manual North American Model Caution: Federal law restricts this device to sale by or on the order of a physician or dentist. MR Unsafe - Do not place or use Miniscav in or near an
More informationThe Symbol means that the Vet-Tech (200, 250 or 300HF) system intentionally applies some radioelectric energy for diagnostic or treatment purposes.
IDENTIFICATION The Vet Tech X-ay unit is available with 3 powers: see the box below Denomination 200HF 250HF 300 HF Usual name Vet Tech 200HF Vet Tech 250HF Vet Tech 300HF Power 12 kw 20 kw 30 kw Milli
More informationOPERATOR S INSTRUCTIONS (for USA & Canada)
MODEL 097 DENTAL X-RAY OPERATOR S INSTRUCTIONS (for USA & Canada) WARNING This X-ray equipment may be dangerous to patients and operators unless safe exposure factors and operating instructions are observed.
More informationUser Manual. Before Using Your WiTouch Pro Device
User Manual Before Using Your WiTouch Pro Device Sync the Remote Control and the WiTouch Pro Device. Using the provided screwdriver, remove the back cover from the WiTouch Pro device. 2. Remove the clear
More informationOPERATOR'S INSTRUCTIONS DENTAL X-RAY MODEL 096
DENTAL X-RAY MODEL 096 OPERATOR'S INSTRUCTIONS 0197 WARNING: This X-ray equipment may be dangerous to patients and operators unless safe exposure factors and operating instructions are observed. R Table
More informationThis annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation
Annex to declaration accreditation (scope accreditation) Locations where activities are performed under accreditation Location Abbreviation/ location code Head Location Vijzelmolenlaan 5 & 7 3447 GX oerden
More informationThis product may malfunction due to electromagnetic waves caused by portable
1 IMPORTANT NOTICE This product may malfunction due to electromagnetic waves caused by portable personal telephones, transceivers, radio-controlled toys, etc. Be sure to avoid having objects such as, which
More informationProduct Name: COMPER SMART DOPPLER FETAL MONITOR. Product Model: DFMX
DFMX User Manual Document Num: History of Change: User Manual JS02114DFMX V1.0 Issue Date: Version: Editor: Reviewer: Approver: Date:xx-xx-xx Date:xx-xx-xx Date:xx-xx-xx Product Name: COMPER SMART DOPPLER
More informationBodyclockStimplusManual.qx8_Layout 1 17/08/ :53 Page 1. Body Clock Stimplus. Instructions for use
BodyclockStimplusManual.qx8_Layout 1 17/08/2012 11:53 Page 1 Body Clock Stimplus TM Instructions for use BodyclockStimplusManual.qx8_Layout 1 17/08/2012 11:53 Page 2 Acupuncture is an ancient Chinese therapy
More informationCardioMessenger II-S Transmitter for BIOTRONIK Home Monitoring. Technical Manual
CardioMessenger II-S Transmitter for BIOTRONIK Home Monitoring 362454_D_GA_CM_II-S_US.indd 1 Technical Manual 17.04.08 16:28:16 by BIOTRONIK GmbH & Co. KG All rights reserved. Specifications subject to
More informationDraft. User s Manual. Transmitter Model EX1150
User s Manual Merlin @home Transmitter Model EX1150 CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 2008 St. Jude Medical Cardiac Rhythm Management Division.
More informationSJM MRI Activator. Handheld Device. User's Manual. Model EX4000
SJM MRI Activator Handheld Device User's Manual Model EX4000 Unless otherwise noted, indicates that the name is a trademark of, or licensed to, St. Jude Medical or one of its subsidiaries. ST. JUDE MEDICAL
More informationCompressor Nebulizer. Model No: 9R-021 series. Please read the instruction manual before use.
Compressor Nebulizer Model No: 9R-021 series Please read the instruction manual before use. IMPORTANT SAFEGUARDS...... 1 1. INTRODUCTION... 6 2. PRODUCT DESCRIPTION... 7 3. OPERATION... 8 4. CLEANING...
More informationOperating Manual D-ACTOR 100
Operating Manual D-ACTOR 100 Published March, 2012 Original language: German STORZ MEDICAL AG Lohstampfestr. 8 CH-8274 Tägerwilen Switzerland 22629»elite edition +«11 381 02 0312 blank page 11 381 02 0312
More informationAUTOMATIC BLOOD PRESSURE MONITOR (Arm Cuff Type) INSTRUCTION MANUAL
AUTOMATIC BLOOD PRESSURE MONITOR (Arm Cuff Type) INSTRUCTION MANUAL Model: SPBP-04 English Instruction Guide Thank you for choosing Advocate as your monitor of choice. The first, most important part of
More informationMODEL PCU Pressure Control Unit with Patient Isolation. Instructions for Use (IFU) Sensors.Systems.Solutions.
World Headquarters Millar Instruments, Inc. 6001-A Gulf Freeway Houston, Texas 77023-5417 USA Phone: 832.667.7000 or 800-669-2343 (in the USA) Fax: 832.667.7001 Email: info@millarmail.com Web site: www.millarinstruments.com
More informationTM Machine WetAlert TM Wireless Wetness Detector In-center User s Guide
2008K@home TM Machine WetAlert TM Wireless Wetness Detector In-center User s Guide 2008K@home WetAlert Wireless Wetness Detector In-Center User s Guide Copyright 2012-2014, 2016, Fresenius USA, Inc. All
More informationUser instructions for the ABI-system 100
User instructions for the ABI-system 100 0124 User instructions for the ABI-system 100 1 ABI-system 100 2 CA04 cuffs (for upper arms) 2 CL04 cuffs (for legs) 1 ABI software CD 1 USB cable 1 boso mains
More informationDIGITAL BLUETOOTH THEROMETER PBT
DIGITAL BLUETOOTH THEROMETER PBT Index 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Introduction Important Information Before Use Product Identification Description of LCD Display Battery Installation
More informationPain Management System
TM Pain Management System Model: ireliev Model #: ET-1313 Operating & Instruction Manual Read Before Using ireliev Pain Management System Intended Use The ireliev Pain Management System (Model # ET-1313)
More informationExergen TAT 5000S RS232 TTL Supplemental Instructions for Use
www.exergen.com/s Exergen TAT 5000S RS232 TTL Supplemental Instructions for Use For additional specifications, see GE Healthcare CARESCAPE V100 Vital Signs Monitor Operator's Manual, Section 12. Symbol
More informationOne-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems
One-day Conference 18 March 2017 Power Supply, EMC and Signalling, in Railway Systems EMC Management and Related Technical Aspects in Railway Systems By Dr Peter S W LEUNG http://www.ee.cityu.edu.hk/~pswleung/
More informationHow to use the Barcode Scanner:
How to use the Barcode Scanner: Please click on [TwMCA-App] icon shown on Desktop. Then click it to execute Barcode scanner software. Then select [Decode ON] button on the application software to turn
More informationPIEZON 707 BIK PIEZON 707 BIK LED
PIEZON 707 IK PIEZON 707 IK LED Installation manual for a-dec 500 and 300 delivery systems with deluxe touchpad Caution! Federal (US law restricts this device to sale by or on the order of a dentist. F-606_HF_rev_-01_Installation
More informationRelief. At Last. User Manual For an effective treatment, read the entire User Manual before using Kyrobak.
Relief. At Last. User Manual For an effective treatment, read the entire User Manual before using Kyrobak. Contents Know Your Kyrobak 2 Safety Instructions 3 Before You Start 4 How to Use Kyrobak 5 Operating
More informationAeroDR Stitching System
DIRECT DIGITIZER Operation Manual AeroDR Stitching System EN 06 Contents Introduction................. 5 Introduction.............................. 6 Summary of usability specifications (for IEC/EN 60601-1-6,
More informationThis annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation
Location(s) where activities are performed under accreditation Head Office Vijzelmolenlaan 5 & 7 3447 GX oerden The Netherlands Location Abbreviation/ location code Vijzelmolenlaan 5 & 7 3447 GX oerden
More informationProduct Manual N.2 WEARABLE ECG. PRODUCT MANUAL
Product Manual WEARABLE ECG www.vitaljacket.com www.biodevices.pt Biodevices S.A. Av. D. Afonso Henriques, 1462 1º Traseiras 4450-013 Matosinhos Portugal N.2 O NOVO NORTE PROGRAMA OPERACIONAL REGIONAL
More informationPower supply CP-T 48/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationNerve stimulator TWISTER
Nerve stimulator TWISTER INSTRUCTIONS FOR USE Softwareversion 1.19 Manufacturer: Dr. Langer Medical GmbH Fabrik Sonntag, Haus 4a 79183 Waldkirch Germany Table of contents 1 Intended use... 5 2 Common
More informationTEST REPORT... 1 CONTENT...
CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2
More informationEMC Test Report. Report Number: M030826
Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report
More informationBy Paul Aylett at 12:08 pm, Apr 13, 2016
TD2 Series Content Introduction Parts Features General Warnings and Safety Using your TENS Pain Reliever Troubleshooting Positions for use Specification Compatibility EMC Maintenance and Cautions Explanation
More informationPower supply CP-T 24/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationMDW-45 Converter RS RS-422/485
www.westermo.com MDW-45 Converter RS-232 - RS-422/485 2 6617-2203 General information Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties
More informationUser Manual. Glass Body Fat Analyzer LS203-B. version:1.0
version:1.0 User Manual Glass Body Fat Analyzer LS203-B Contains FCC ID: OU9AW8001-LS GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD Zone A, 5/F., Investment Building, No. 12, Huizhan East Rd., Torch
More informationNational Voluntary Laboratory Accreditation Program
National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Compatible Electronics, Inc. 114 Olinda Drive Brea, CA 92823 Mr. Jeff Klinger Phone: 714-579-0500 Fax: 714-579-1850
More informationNational Voluntary Laboratory Accreditation Program
National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Element Materials Technology Elbridge 4939 Jordan Road Elbridge, NY 13060 Mrs. Vicki Albertson Phone: 503-844-4066
More informationStandard Electric Console REF Instruction for Use
Standard Electric Console REF 1020 Instruction for Use - TABLE OF CONTENTS - Model 1020 Standard Electric Console Instruction Manual System Overview and Intended Use... 1 Applicable Accessories and Part
More informationHoliday Detector mod. 284/35KV
Holiday Detector mod. 284/35KV Telemagnetica S.r.l. Via Teocrito, 36-20128 Milan - Italy Tel: +39-022552900 - Fax: +39-022553097 e-mail: info@telemagnetica.com - http: January 2013 BR-284-35KV-ENG-00 Pag.
More informationPower supply CP-T 48/5.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationTransmitter Model EX1100, EX1100W. User's Manual
Merlin@home Transmitter Model EX1100, EX1100W User's Manual Unless otherwise noted, indicates that the name is a trademark of, or licensed to, St. Jude Medical or one of its subsidiaries. ST. JUDE MEDICAL
More information