Jack Anderson Ball Park July 31, 2014 Concessions and Restroom Ashland, Nebraska ADDENDUM NO. 1

Similar documents
Project: NEW CONCESSIONS/ TOILET BUILDINGS FOR FLOMATON HIGH SCHOOL FOR THE ESCAMBIA COUNTY BOARD OF EDUCATION BREWTON, ALABAMA

A. This Section includes plumbing fixtures and related components.

ADDENDUM NO. 2. The Bid Opening has not changed it remains December 8, 2016 AT 1:30 P.M.

Requ est fo r sea led bids for an addition to Be ave r Lake Bathhouse

2016 CDM Smith All Rights Reserved July 2016 SECTION PLUMBING - FIXTURES AND TRIM

SECTION PLUMBING FIXTURES

The BEST Plumbing Specialties. One Source. A 15

RENOVATION OF THE FARMERS MARKET Reference Number:

BUILDING OVERHANG (6'-0") STREET TREES IN 5X5 PLANTER BEDS ALONG E GRAND PLANTER BEDS

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

Addendum. Windsor Hall Renovations Date: October 12, 2017 Addendum No: 3 GENERAL. 1! Addendum #4 will be issued 2:00 PM Tuesday October 17, 2017.

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

TELEPHONE: (215) Addendum No New Solomon Solis-Cohen Elementary School SDP Contracts No. B-075C, B-076C, B-077C and B-078C of 2017/18

OCPS Submittal Register for Product Data and Shop Drawing Reviews

Marshall Truck Station Laboratory Addition Project No. TZ MnDOT

New Product Release: October 2014 Boone Racks

ADDENDUM NO. 3. Ellis County Elections Building

DESIGN DRAWING INDEX PROJECT INFO. WEATHERBY / PIPER MCKEE GROUP x 136

ADDENDUM #1. April 29, 2009

RemoteTeller SYSTEM - RTS VAT 21 GX CUSTOMER UNIT COMPONENTS CUSTOM DESIGNED CUSTOMER AREA

Wendell E Green Elementary School 1150 W 96th St Chicago, IL 60643

Multi-Institutional Academic Health Science and Research Center. PS701 from the conformed documents folder. These are obsolete drawings

Single-Family Dwelling Submittal Requirements

Introduction. Classifications of piping: Industrial. Residential (i.e., plumbing) Carries liquids and gases used in the manufacture of products

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

EDUCATION GRADE 12 JUNE EXAMINATION 2013 UMLAZI / ILEMBE / UGU ENGINEERING GRAPHICS AND DESIGN PAPER 1 MANUFACTURING ENGINEERING & TECHNOLOGY

Answer: Only to ChurchWoods, LLC.

Product Data (500) Wall thickness not to exceed 3"

Design and Construction Standards SECTION ATHLETIC LOCKERS

Construction Guidelines 1

BUILDING PLANS. BUILDING INSPECTIONS DEPARTMENT

Mahalia Jackson Elementary School 917 W 88th St Chicago, IL 60620

Addendum #1 - Bid Package #

ADDENDUM NO. 4 TO THE CONTRACT DOCUMENTS SUPPLEMENTAL INFORMATION

WADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains.

DOCUMENT LIST OF DRAWINGS, TABLES AND SCHEDULES

ALL PLAN HOLDERS NANCY MAGER, NPSR ARCHITECTS, INC. DATE: November 29, Lea County General Service Building PROJECT NO: ADDENDUM NO: 1

PLAN SUBMITTAL REQUIREMENTS

SUBMITTAL REQUIREMENTS FOR COMMERCIAL SIGNAGE PROJECTS

BUILDING PLANS. BUILDING DEPARTMENT

A1.1 FOX GARAGE VAN VAN VAN VAN 11/16/ WASHINGTON BLVD ST. LOUIS, MO REVISIONS FLOOR PLAN - LEVEL /01/14

Montclair, NJ ADDENDUM NO. 1 Issue Date: May 15, 2017

LIST OF ARCHITECTURE PLANS

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

SECTION (10670) - WIRE CLOSET AND UTILITY SHELVING

03/7/12 Issuance UTD Section Page 1 of 5 Electrical General

CS2.0 COVER SHEET VOL. 2

TO WHOM IT MAY CONCERN:

City of Thousand Oaks

December 31, 2015 A. THE BID OPENING DATE IS UNCHANGED. B. Questions, Additions, and Deletions

Jackie Robinson Elementary School

ADDENDUM NOTICE INTERIOR RENOVATIONS AT THE BATHURST CLARK RESOURCE LIBRARY, 900 CLARK AVENUE WEST, VAUGHAN, ON

Design Deliverables. Summary. A. Expectations for Design Deliverables:

HAYES VALLEY PLAYGROUND AND CLUBHOUSE PROJECT NO.: SAN FRANCISCO PARKS AND RECREATIONS SAN FRANCISCO, CA

SECTION (10670) - WIRE CLOSET AND UTILITY SHELVING

REQUEST FOR PROPOSALS ADDENDUM

DOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410

Product Guide Specification

Marcus Moziah Garvey Elementary School S Morgan St Chicago, IL 60643

NEW SINGLE FAMILY HOMES

February 18, Re: Zephyr Lakes Amenity Center Zephyrhills, Florida

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

Residential Construction Checklist Single and Two Family Construction

Residential Room Addition / Remodel Submittal Requirement Checklist

Installation and Maintenance Instructions

ADDENDUM NO: 1 IFB/RFP No: NKU Commodity: Kentucky Hall Renovation Date: 12/7/2017 Due Date: 12/18/2017

Grease Interceptor Design Checklist

Junction Box. Digitrace C910 Electronic Controller. Thermal Pipe. Ambient Control Rtd. Insulation. Rayclic-E End Seal. XL-Trace Heating Cable

HAMMEL ASSOCIATES ARCHITECTS, LLC 2 5 E A S T G R A N T S T R E E T, S U I T E L A N C A S T E R, P E N N S Y L V A N I A

ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Electrical/Telecommunications Design

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

Marcus Moziah Garvey Elementary School

BIRMINGHAM CITY SCHOOLS (BCS) OPERATIONAL CENTER COMPLEX: BID PACKAGE D

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

ADDENDUM #2 September 12, 2018

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT. Addendum No. 2

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

5/4/2010 DATUM 644 GREAT ALASKAN RENTAL PACKAGE DRAINAGE SYSTEM/HEAT-PREWIRE DRAINAGE SYSTEM-HEATED CODES/STANDARDS USA 265 CODES/STANDARDS-CSA/CMVSS

PART # DESCRIPTION Wt./(Lbs.) US$ List MC-100 Standard nipple trim kit only for adj. chair carriers:mc-10, MC-12, MC-13* $419.

* TURNING SPACE ROLLED CURB SIDEWALK RAMP TYPE R (ROLLED SIDES) * TURNING SPACE ** RAMP

Charles P Caldwell Academy of Math & Science ES 8546 S Cregier Ave Chicago, IL 60617

2016 CALIFORNIA BUILDING CODE - SECTION 11B-213 & DIVISION 6 GENERAL REQUIREMENTS FOR TOILET & BATHING FACILITIES

Symphony II Adaptable Table System

This is being reviewed, additional comment to follow Marmoleum tile has been removed and replaced with a biobased VCT.

Geberit Duofix. Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio

THE CHURCH OF J ESUS CHRIST OF LATTER-DAY SAINTS BISHOPS' STOREHOUSE THE CHURCH OF OF LATTER-DAY SAINTS HOME STORAGE CENTER BISHOPS' STOREHOUSE

Everett McKinley Dirksen Elementary School

SUNSET & FRANCISQUITO SHOPPING CENTER S I G N P R O G R A M

DECK PERMIT APPLICATION PACKET

SECTION THERAPEUTIC POOL ACCESSORIES

PART MATERIALS. Section Fencing Materials. Description

WALKS AND SIDEWALKS REQUIREMENTS:

76'-0" 10'-5 7/8" 10'-2" 3 7/8 15'-10 1/8" 5'-0" 42'-1 7/8" DINING. IS x83 KITCHEN. 36x80 CLAYTON WAKARUSA

REVISION #1. Section. fire alarm B. C. the hot. intent of. required. manufacturer. materials. C. Warranty

FAB GSE Remodel ITB Solicitation #1538 Invitation to Bid (ITB) for General Contracting Services. ADDENDUM #4 December 5, 2014

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

1.01 NOTICE TO BIDDERS

Transcription:

Jack nderson Ball Park July 31, 2014 Concessions and Restroom shland, Nebraska 663-005-12 The rchitect/ Engineer issues this addendum, applicable to the above named project, to all known Contractors before receipt of proposal. This addendum includes Item Number 1-1 thru 1-16. This addendum item shall be fully incorporated into the Bidding/Contract Documents and have the same force and effect as though originally included. The Bidder shall acknowledge receipt of this ddendum No. 1 on the Bid Proposal Form in the place provided. GENERL Item 1-1: Section 00 11 13 dvertisement for Bids Refer to section 1.4. Pre-Bid meeting. ttached are copies of the meeting sign in sheet for reference. The following items were discussed at the Pre-Bid meeting: a. The project does not include liquidated damages. b. The project is tax exempt. c. The City of shland has waiver the building permit fee. d. Construction documents have been submitted to the State Fire Marshal for review. CIVIL Item 1-2: Drawing C1.01 Site Utility Plan Refer to utility plan drawing. Change Bore Diameter to a 4 D.I. C900. Provide reducing fittings at either end to tie back into the 3 service. LNDSCPE Item 1-3: Drawing L2.01 Site Layout Plan RCHITECTURL dd the following note to the drawing: Contractor shall provide a temporary chain link or orange construction fence around the building construction area. Item 1-4: Drawing 1.01 Floor Plans, Reflected Ceiling Plans, Roof Plans, Room Finish Schedule, Signage Details Refer to the breezeway between the Concessions and Restroom areas. The CMU in this area shall be Standard Smooth Face Integrally Colored 8 x8 x16 Running Bond CMU DD1-1

Jack nderson Ball Park July 31, 2014 Concessions and Restroom shland, Nebraska 663-005-12 Item 1-5: Drawing 6.01 Interior Elevations, Casework Sections, Door Schedule, Frame Types, Stair Section Reference Door Schedule and Frame Types. Revise door height of all doors from 7-2 to 7-0. Provide 4 header in lieu of stacked 2 headers at all door frames to match 7-4 rough opening height. Item 1-6: Section 03 00 00 Cast-In-Place Concrete Refer to section 2.6,, 1, subject to compliance with the requirements of the section, add Viper Check II by Insulation Solutions, Inc. as an acceptable product. Item 1-7: Section 08 41 13 luminum-framed Entrances and Storefronts Refer to section 2.4,, 2c. Revise Texture from Embossed to Smooth. Item 1-8: Section 08 41 13 luminum-framed Entrances and Storefronts Refer to section 2.10,. Revise Clear nodic Finish from Class I to Class II. Item 1-9: Section 08 71 00 Door Hardware Refer to section 3.7, B. Remove Set 6.0 from spec, as Door 106 does not exist in the project. STRUCTURL Item 1-10: Section 06 17 53 Shop-Fabricated Wood Trusses Reference Paragraph 2.2.C. Replace this paragraph with the following: Grade and Species: Provide dimension lumber of any species for truss chord and web members, graded visually or mechanically, and capable of supporting required loads without exceeding allowable design values according to FP s National Design Specifications for Wood Construction and its Supplement. Item 1-11: Drawing S1.01 Structural Plans & Details Reference Section Detail 3. Revise model number of Simpson Strong-Tie anchor from H610 to HG10. MECHNICL Item 1-12: Drawing M2.01 Mechanical Piping Plans Reference SDM-001 for a revised First Floor Piping Plan to add a grease interceptor location and pipe routing in Concession Room DD1-2

Jack nderson Ball Park July 31, 2014 Concessions and Restroom shland, Nebraska 663-005-12 Item 1-13: Drawing M3.01 Mechanical Riser & Details Reference SDM-002 for a revised Waste and Vent Riser Diagram for pipe routing of grease interceptor. Item 1-14: Drawing M4.01 Mechanical Schedules Reference SDM-003 Plumbing Fixture and Equipment Connection Schedule to add grease interceptor information. ELECTRICL Item 1-15: Section 265100, Lighting Fixtures Item 1-16: Drawing E0.01 The following lighting fixtures have been reviewed in accordance with paragraph 2, and are included in the Contract Documents for bidding purposes. ll fixtures, lamps, and ballasts are required to meet the specification requirements regardless of prior approval. Prior approval does not waive any requirements indicated on the drawings or the specifications. Some fluorescent fixtures require dimming or multiple levels of switching. The required number and types of ballasts shall be provided to meet the switching requirements shown on the drawings. Type Manufacturer and Catalog Number COOPER CTLOG NUMBER: WN-232-UNV-EB81-U B ERCO CTLOG NUMBER: 85104.023 EMER EMERGI-LITE CTLOG NUMBER: EL-2LED D COOPER CTLOG NUMBER: GLEON-E-03-LED-E1-T2-BK COOPER POLE CTLOG NUMBER: RSS420SY1 dd the following to Key Note #2: The Existing Rack Mounted Panel is a Siemens Panel Type 1, 250 amp max, with BQD type breakers. END OF DD1-3

CONCESSIONS 2" W DN TO 3" FS-1 - S-1 01 L-1 GI-1 WH-1 CW 1 1/2" V STORGE EWH-2 MOUNTED HIGH ON WLL ON NGLE IRON FRME. INSTLL WITH DRIN PN ND PIPE PN THROUGH WLL TO THE FLOOR SINK UNDER THE SINK. SLOPE SECURE STOR FIRST FLOOR PIPING PLN SCLE: 1/4"=1'-0" Jack nderson Ball Park Concessions and Restrooms shland, NE TCEP Project No.: 663-005-12 rchitecture + Landscape rchitecture + Engineering + Interiors 1010 Lincoln Mall, Suite 200 Lincoln, NE 68508-2883 402 477.9291 Fax 402 477.6542 Kansas City, MO Fairway, KS www.clarkenersen.com ddendum #01 Supplemental Drawing: SDM-001 Revision of Sheet: M2.01 Date: July 31, 2014

1 1/2" V 2 2" W L-1 3" W 01 3" FS-1 GI-1 S-1 2" W 4" W WSTE ND VENT RISER DIGRM SCLE: NO SCLE Jack nderson Ball Park Concessions and Restrooms shland, NE TCEP Project No.: 663-005-12 rchitecture + Landscape rchitecture + Engineering + Interiors 1010 Lincoln Mall, Suite 200 Lincoln, NE 68508-2883 402 477.9291 Fax 402 477.6542 Kansas City, MO Fairway, KS www.clarkenersen.com ddendum #01 Supplemental Drawing: SDM-002 Revision of Sheet: M3.01 Date: July 31, 2014

PROVIDE MOP & HOSE HNGER & STINLESS STEEL WLL GURDS. 01 DF-1 (H)UR-1 (H)WC-1 FS-1 FD-1 FD-2 GI-1 WH-1 HB-1 EWH-1 EWH-2 DET-1 DET-2 DRINKING FOUNTIN URINL (HNDICPPED) WTER CLOSET FLOOR SINK FLOOR DRIN (FINISHED RES) FLOOR DRIN (EQUIPMENT ROOMS) GRESE INTERCEPTOR WLL HYDRNT HOSE BIBB ELECTRIC WTER HETER ELECTRIC WTER HETER DOMESTIC WTER EXPNSION TNK DOMESTIC WTER EXPNSION TNK FUCET: FOUNTIN: FIXTURE: VLVE: CRRIER: FIXTURE: VLVE: SET: CRRIER: DRIN: DRIN: DRIN: INTERCEPTOR: HYDRNT: BIBB: HETER: HETER: TNK: TNK: MOEN COMMERCIL MODEL 8124 EQUIVLENT. CHROME PLTED 10-1/4" SPOUT WITH VCUUM BREKER, WLL MOUNTING BRCKET, PIL HOOK ND 2-1/2" LEVER HNDLES. CORN MODEL 152400-W32-FR4 BI-LEVEL OR EQUIVLENT 18 GUGE, 304 STINLESS STEEL WITH FREEZE RESISTNT VLVE. KOHLER MODEL K-4960-ET BRDON OR EQUIVLENT WHITE VITREOUS CHIN, INTEGRL TRP, TOP SPUD, ELONGTED LIP, 1 GL PER FLUSH. SLON ROYL 186-1 LOW CONSUMPTION OR EQUIVLENT 1.0 GLLON PER FLUSH WITH D COMPLINT OPERTING HNDLE. WLL HUNG KOHLER MODEL K-4330 KINGSTON EQUIVLENT 1.6 GL FLUSH, WHITE VITREOUS CHIN, WLL HUNG, SIPHON JET WITH TOP SPUD. SLON ROYL MODEL 111, LOW CONSUMPTION OR EQUIVLENT 1.6 GLLON PER FLUSH, D COMPLINT OPERTING HNDLE. WHITE, OPEN FRONT, HEVY DUTY COMMERCIL GRDE NO LID ON SET. WLL HUNG. JY R. SMITH MODEL 3150Y OR EQUIVLENT. CST IRON BODY WITH FLNGE, 8" DEEP CID RESISTNT EPOXY INTERIOR. INTEGRL CLMPING COLLR, SEEPGE OPENINGS, LOOSE SET 3/4 NICKEL BRONZE 12"x12" GRTE, DOME STRINER, NO HUB CONNECTION. JY R. SMITH MODEL 2005Y OR EQUIVLENT. CST IRON BODY WITH FLNGE. INTEGRL REVERSIBLE COLLR, SEEPGE OPENINGS, 5" DI. STIN NICKEL BRONZE STRINER, NO HUB CONNECTION. JY R. SMITH MODEL 2230Y OR EQUIVLENT. CST IRON BODY WITH FLNGE. INTEGRL CLMPING COLLR, SEEPGE OPENINGS, LOOSE SET GRTE, SEDIMENT BUCKET, NO HUB CONNECTION. SCHIER PRODUCTS MODEL PTG-1412 OR EQUIVLENT POLYETHYLENE 10 GPM, 20 LB GRESE CPCITY, PROVIDE WITH STNDRD 2" INLET ND OUTLET. WOODFORD MODEL 67 FROST PROOF UTOMTIC DRINING, BCKFLOW PREVENTER, FROST PROOF HYDRNT WITH SSE 1052 PPROVED TWO CHECK BCK FLOW PREVENTER, CHROME FINISH HOSE CONNECTION STINLESS STEEL STEM, LOOSE KEY OPERTING HNDLE, SEE NOTE 3 WOODFORD MODEL 26, C INLET WLL FUCET WITH SSE 1052 PPROVED TWO CHECK BCKFLOW PREVENTER, BRSS FINISH, HOSE CONNECTION WHEEL OPERTION HNDLE.. O. SMITH MODEL DEL-40 OR EQUIVLENT 40 GLLON STORGE TNK, 23 GPH T 80 DEGREE F RISE. DUL NON SIMULTNEOUS 4,500 WTT ELEMENTS, 208 VOLT / 1 PH / 60 HZ.. O. SMITH MODEL DEN-30 OR EQUIVLENT 30 GLLON STORGE TNK, 23 GPH T 80 DEGREE F RISE. DUL NON SIMULTNEOUS 4,500 WTT ELEMENTS, 208 VOLT / 1 PH / 60 HZ. MTROL THERM-X-TROL ST-5 OR EQUIVLENT. 2.0 GLLON, 8" DIMETER, 12.5" HIGH DIPHRM TYPE EXPNSION TNK SPECIFICLLY DESIGNED FOR POTBLE WTER. MTROL THERM-X-TROL ST-5 OR EQUIVLENT. 2.0 GLLON, 8" DIMETER, 12.5" HIGH DIPHRM TYPE EXPNSION TNK SPECIFICLLY DESIGNED FOR POTBLE WTER. 2" 4" (SEE PLNS) (SEE PLNS) (SEE PLNS) 2" 2" (SEE PLNS) (SEE NOTE 1) (SEE PLNS) (SEE NOTE 1) (SEE PLNS) (SEE NOTE 1) 1/2" 1" REFER TO RCHITECTURL INTERIOR ELEVTIONS FOR FIXTURE MOUNTING HEIGHTS OR MOUNT T MNUFCTURERS RECOMMENDED HEIGHTS. PLUMBING SCHEDULE NOTES: 1) MINIMUM SIZE OF UNDER SLB VENT SHLL BE 2". 2) LL HNDICPPED LVTORIES (HL-#) & LL CL-1'S SHLL BE INSTLLED WITH P-TRP ND SUPPLY INSULTION. PROVIDE TRUEBRO MODEL #102 OR EQUL WITH P-TRP INSULTION, HOT ND COLD WTER NGLE VLVE ND SUPPLY INSULTION FBRICTED FROM CLOSED CELL VINYL, 3/16" WLL THICKNESS. "K" VLUE OF 1.17 (BTU*IN/HR*FT^2*DEG F). 3) CONTRCTOR SHLL VERIFY LL WLL THICKNESS ND SHLL ORDER PPROPRITE OPERTING ROD SSEMBLY. 4) SUPPLY STOPS MY BE ELIMINTED T THE CONTRCTORS OPTION WHEN PLUMBING FIXTURE IS LOCTED IN CBINET ND THE FIXTURE HS SHUT-OFF VLVES TO ISOLTE THE FIXTURE FROM THE OTHER FIXTURES. ESCUTCHEONS MY BE ELIMINTED WHERE THE SUPPLIES PENETRTE THE BOTTOM OF CSEWORK. Jack nderson Ball Park Concessions and Restrooms shland, NE TCEP Project No.: 663-005-12 rchitecture + Landscape rchitecture + Engineering + Interiors 1010 Lincoln Mall, Suite 200 Lincoln, NE 68508-2883 402 477.9291 Fax 402 477.6542 Kansas City, MO Fairway, KS www.clarkenersen.com ddendum #01 Supplemental Drawing: SDM-003 Revision of Sheet: M4.01 Date: July 31, 2014