Introduction.

Similar documents
HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Outdoor, CCTV or CCTV, Fig 8 Armored.

Outdoor, Fig 8 Armored, Multi Tube

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

JFOC-BSG2D MODEL:JFOC-BSG2D. optic.com. For detailed inquiry please contact our sales team at:

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

Standard Monotube SAFE

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

SPECIFICATION. Optical Fiber Cable

CommunicationCables FIBER OPTICS OPGW FTTH

features and benefits

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

Datasheet Outside Plant Cable

u n a B Optical Cables UNIFLEX CABLES LTD.

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

Ø 1250 * 688 mm 93 kg ± 105m

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

ENDLESS INNOVATION OPTICAL FIBER. Bendfree Bendfree+ UltraPass. WidePass. Ultra Bendfree

Ø560*336mm 4.25 kg 2100 ± 105m

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

Single-Armored Cables, Fibers

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

Fiber Optic Outside Plant Cables (4-144 Fibers)

ETK Kablo SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -LWP)

OFS AllWave non-dispersion shifted single-mode optical fiber

SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE

Nufern 980 nm Select Cut-Off Single-Mode Fiber

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

Medium Voltage Power Cables

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

ZHONGTIAN TECHNOLOGIES CO., LTD

Optical Ground Wires (OPGW)

Industrial Automation

Type QG-G50-2C- M-BU

ZHONGTIAN TECHNOLOGIES CO., LTD

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES FIBER OPTICS CO., LTD

Copper and Fiber Optic Cables

kv: medium voltage reeling cable with fibreoptics

FTTH Fiber Optical Cable

Exhibit A Construction Project Manual and Drawings

Why Using Fiber for transmission

FiberHome Fiber Products

Integrating Global Communications...

There are lots of problems or challenges with fiber, Attenuation, Reflections, Dispersion and so on. So here we will look at these problems.

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Filled Solid ALPETH Cable

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

VSOF-BS403A. Splice Closure for Fiber Optic Cable User Manual Rev.3

S-Link. RF Cable Solution

Optical Systems Contents

ITU-T G.656. Characteristics of a fibre and cable with non-zero dispersion for wideband optical transport

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR FlexNAP DISTRIBUTION SYSTEMS: DISTRIBUTION TRUNK, TAP, AND TETHER. July 2018.

FSM-30P SPECIFICATIONS FOR FIBER FUSION SPLICER 1. GENERAL

Z EE E E Z E Z Z Z Z Z

Total care for networks. Introduction to Dispersion

Fiber Optic Principles. Oct-09 1

CONTENTS. Introduction Characteristics Product range Pages

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

Outside Plant All Dielectric

Fiber Optic Communication Systems. Unit-05: Types of Fibers.

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

OptoLup TM POF cable Data Sheet. Overview. COMOSS OptoLup TM Cable is a type of APF, All. for the transmitting. compliant POF cables.

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

PERFORMANCE SPECIFICATION SHEET

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

Fiber Joints and Couplers; Cable Design. Dr. Mohammad Faisal Dept. of EEE, BUET

COPPERCLAD STEEL WIRE. Dead Soft Annealed Jacketed High Strength. Extra High Strength Composite Conductors Guy Wire

Power Cables and their Application

Connection technology for wireless communication systems

Light Guide Overview

Fibre Optic Indoor/Outdoor Cable

ABOUT US ABOUT US 1 CRANE CABLES

TURNKEY, ULTRA STABLE, OEM LASER DIODE SOURCE OZ-1000 & OZ-2000 SERIES

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

To offer our customer the highest quality Broadband products at a competitive price with efficient Delivery and Inventory.

PRO BEAM Series PRO BEAM expanded beam field deployable interconnect F739

OptiSheath Advantage Sealed Terminal Solution for WDM Applications, UCA4-XX An Evolant Solutions Product

ELECTRICALLY CONTROLLED VARIABLE FIBER OPTIC ATTENUATOR

E2-E3 CONSUMER FIXED ACCESS. CHAPTER-4 OVERVIEW OF OFC NETWORK (Date Of Creation: )

Advanced Fibre Testing: Paving the Way for High-Speed Networks. Trevor Nord Application Specialist JDSU (UK) Ltd

Lectureo5 FIBRE OPTICS. Unit-03

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

3M Clear Track Hallway Fiber Pathway

Canadian OSP Copper I-1. Table of Contents

The absorption of the light may be intrinsic or extrinsic

ITU-T G.654. Characteristics of a cut-off shifted single-mode optical fibre and cable

Transcription:

Introduction On the theshold of the 21st Century, we find ourselves with forms of communication and information that exceed all humankind s expectations. The advance of technology has brought together thousands of people and uncountable companies, joined in the ongoing process of globalization, mainly through telecommunications and data communication networks. Furukawa, a company specialized in developing systems in this field, is a leading manufacturer of fiber optic cables, applying cutting-edge technology to building products for conveying information. This evolved from Furukawa s decision, in 1974, to set up activities in Brazil, to make aluminum cables at its Lorena plant, in the State of São Paulo. In 1977, it opened in Curitiba one of the most modern factories of telephone, electronic and optic cables, as well as beginning a pioneering activity in Wide Band systems. From then on, Furukawa has never stopped. Having consolidated its image in this new technological scenario, it herewith issues its most recent Optic Fiber and Cable Catalog, providing the information and specifications required for proper system deployments. With Furukawa-designed Fiber Optic systems, the information payload flows faster and efficiently, bringing technology closer to everyone. Rounding out its activities, Furukawa also prepares projects and carries out deployments in all areas related to telecommunication and data networks for companies and institutions seeking state-of-the-art technology. BUILDING THE NETWORKS OF THE FUTURE www.furukawa.com.br 1

TABLE OF CONTENTS Coding... 3... 4 Outdoor Underground Network CFOA-SM-DD-S / CFOA-NZD-DD-S BLOW CABLE... 5 and 6 CFOA-SM-DD-G / CFOA-NZD-DD-G... 7 and 8 CFOA-SM-DD-S / CFOA-NZD-DD-S... 9 and 10 CFOA-SM-DE-G / CFOA-NZD-DE-G... 11 and 12 CFOA-SM-ARE-G / CFOA-NZD-ARE-G CFOA-SM-ARD-G / CFOA-NZD-ARD-G... 13 and 14 CFOA-SM-DPE-G / CFOA-NZD-DPE-G... 15 and 16 CFOA-SM-DER-G (PPU) / CFOA-NZD-DER-G (PPU) CFOA-SM-DER-G (PFV) / CFOA-NZD-DER-G (PFV)... 17 and 18 Outdoor Overhead Network CFOA-SM-ASY-G / CFOA-NZD-ASY-G CFOA-SM-ASY-RA-G / CFOA-NZD-ASY-RA-G... 19 and20 CFOA-SM-LVY-S / CFOA-NZD-LVY-S... 21 and 22 OPGW-SM / OPGW-NZD... 23 and 24 Indoor Plant CFOI-SM-MF / CFOI-NZD-MF CFOI-SM-UB / CFOI-NZD-UB... 25 and 26 COA-SM-MF / COA-NZD-MF Cord... 27 and 28 Characteristics of in Cables... 29 Connectors General... 30 Installation Methods... 31 and 32 Acknowledgement We thank you for deciding to select Furukawa quality products. This Catalog provides the main technical characteristics of Furukawa-made and Cables. The main cables are supplied in loose and tight configurations, designed to meet the requirements of any kind of deployment. The each Fiber s attenuation figure is measured to assure that it complies with the requirements of the strictest specifications. Our Customer Care Center is available to answer any questions on our products at: www.furukawa.com.br 2

OPTICAL CABLES Coding Outdoor Underground Network CFOA-X-Y-W-Z (K) Outdoor Overhead Network CFOA-X-ASY-W-Z CFOA-X-ASY-RA-G-Z CFOA-X-LVY-W-Z-K The cables given in this catalog are coded as follows: Special Characteristics: PFV - Fiberglass protection/ppu - Pultruded-Element Protection Number of Optic G- Gel Core; S - Dry Core Cable Application DD - DE - DPE - ARO - ARE - DER - DDR - Dielectric for installation in ducts Dielectric for directly buried installation Dielectric and protected for directly buried installation Protected with Corrugated Steel Strip for Duct installation Protected with Corrugated Steel Strip for directly buried installation Dielectric and protected from rodents for directly buried installation Dielectric and protected from rodents for duct installation Type of : MM - Multimode / SM - Single Mode / NZD - Non Zero Dispersion Fiber cable jacket Fiber Cable Number of G - Gel Core; S - Dry Core Maximum span - (80, 120, 200 m) AS - Self-supported Type of Fiber: MM - Multimode / SM - Single Mode / NZD - Non Zero Dispersion Fiber cable jacket Fiber Cable Fiber Cable Subscriber Network OPGW Ground Wire Type of Cable Jacket: RT- Trailing-resistant / RC - Flame stopping Number of G - Gel Core; S - Dry Core Maximum span - (300, 400, 500 m) Long span Type of Fiber: MM - Multimode / SM - Single Mode / NZD - Non Zero Dispersion Cable jacket ( ) Indoor Network CFOI-X-Y-Z COA-X-MF Number of Cable Core: MF - Single Fiber / UB - Basic Unit Type of Fiber: MM - Multimode / SM - Single Mode / NZD - Non Zero Dispersion Indoor Fiber Cable Single Fiber Type of Fiber: MM - Multimode / SM - Single Mode / NZD - Non Zero Dispersion fiber cable jacket Cord 3

OPTICAL FIBERS Characteristics Characteristics Requirement Application: Recommende for low-loss and high throug-ban optical systems, such as: long distance systems, trunking networks, data and video distribution and transmission. Single-mode optical fiber with Matched Cladding type index profile and double acrylic jacket. Excellent geometric properties, allowing low-loss splices. Recommended for all types of optical cables, such as loose tube, tight, ribbon or slotted, providing excellent performance. Description: Furukawa-made matched cladding type profile optical fiber for use in the 1310 nm to 1550 nm wavelenght range. Primary acrylic jacket double-coated to 245 µm, providing adequate protection, minimizing its sensitivity to bends. Fiber Cutoff Wavelenght (λ cf) Cable Cutoff Wavelenght (λ cc) Null Dispersion Wavelenght (λ o ) Null Dispersion Stope (S o): To obtain the cromatic dispersion, use the following formula: 4 D (λ) = (λ λ o ) ps/nm.km (for 1200 nm λ 1600 nm) 3 λ Modal Field Diameter 1285 ~ 1330 nm Uniformity of Attenuation 1525 ~ 1575 nm Polarizing Mode Dispersion (PMD) Sensitivity to Bending Dimensional Characteristics Characteristic Mechanical Characteristics Characteristic Constant Mechanical Stress (Proof Test) Jacket Removal Force 1150 nm λ 1330 nm cf 1270 nm 1300 nm λ o 1323 nm 0.092 ps / (nm².km) (9.3 ± 0.5) µm at 1310 nm (10.4 ± 0.8) µm at 1550 nm 0.05 db/km 0.05 db/km 0.2 ps / km ½ 0.10 db / km at 1550 nm Number of Turns = 100 Mandrel el Radius = 37.5 mm Requirement Diameter of Shell (125 ± 2) µm Diameter of Jacket (245 ± 10) µm Modal Field / Shell Concentricity Error 0.8 µm Non-Circularity of Shell 1% Fiber / Shell Concentricity Error 12 µm Environmental Characteristics Thermal Cycle Lengths of Delivery 2.100 m to 25.200 m Specification: ABNT NBR 13488 / ITU-T G-652 Requirement 0,70 Gpa (1.0 %) 1.5 F 5.0 N 0.05 db / km at 1550 nm (-60 ºC to + 85 ºC) 4

OUTDOOR UNDERGROUND NETWORK Cables BLOW CABLE CFOA-SM-DD-S / CFOA-NZD-DD-S Construction Characteristics Types Data CFOA-SM-DD-S CFOA-NZD-DD-S Fiber Primary Fiber Jacket Number of * Cable Core Central Element Tensile Element Core Tie * Other values can be provided through inquiry. Single Mode 4, 6, 8, 10, 12, 18, 24, 30, 36, 48, 60, 72, 96, 120 and 144 Hydro Expandable Material Non-metal Material Synthetic Synthetic Material Wires Black Polyethylene or Copolymer Non Zero Dispersion Application: The accelerated development in telecommunications and the need for higher transmission rates, to provide other services, such as multimedia, internet and remote conferencing, among others, has made optical cables the prime transmission media. These cables, using standard and NZD single-mode fibers, allow operating at high transmission rates, such as in SDH/SONET and ATM, among others, or multiple wavelength, such as WDM or DWDM systems. Its loose type design and the materials used in its manufacture provide full cable protection from bad weather. Indicated for outdoor deployment, such as in urban trunking transport or subscriber access networks. Its corrugated outer sheath provides a lower friction coefficient in ducts and subducts, allowing higher airflow drag efficiency. Dimensional Characteristics Designation BLOW CABLE CFOA-SM-DD-S CFOA-NZD-DD-S * Other lenghts can be provided on inquiry. per Basic Unit Specification: ABNT NBR 14566 and Furukawa PT-1035 External Diameter (mm) Net Mass (kg/km) * Length per Coil (m) 04 to 12 02 9.5 72 6000 18 to 30 06 10.5 85 6000 36 06 11.1 100 6000 48 to 60 12 11.5 103 6000 72 12 12.2 110 6000 96 12 14.0 150 6000 120 12 16.0 190 6000 144 12 18.0 235 6000 Description: Fully dielectric optical cable. Core waterproofed with hydro expandable material (dry core). External black corrugated thermoplastic sheath. 5

OUTDOOR UNDERGROUND NETWORK Mechanical Characteristics CFOA-SM-DD-S / CFO-NZD-DD-S (BLOW CABLE) Formation Maximum Installation Load Compression Resistance Minimum Bend Radius (mm) During Installation Installed Cable 4, 6, 8, 10, 12, 18, 24, 30,36, 48, 60, 72, 96, 120, 144 2 x Weight of Cable per km. Minimum: 2000 1 x Weight of Cable per km. Minimum: 1000 20 x External 10 x External Cable Formation Available from 04 to 144. CFOA-SM-DD-S / CFOA-NZD-DD-S (BLOW CABLE) Tensile Element Filler Protection Tube Central Dielectric Material Waterproofing Ribbons Rip Cord 36 144 6

OUTDOOR UNDERGROUND NETWORK Cables CFOA-SM-DD-G / CFOA-NZD-DD-G Construction Characteristics Data Fiber Primary Fiber Jacket Number of * Cable Core Central Element Tensile Element Core Tie Types * Other lenghts can be provided on inquiry. CFOA-SM-DD-G Single Mode 4, 6, 8, 10, 12, 18, 24, 30, 36, 48, 60, 72, 96, 120 and 144 Gel Non-metal Material Synthetic Non Hygroscopic Material Black Polyethylene or Copolymer CFOA-NZD-DD-G Non Zero Dispersion Application: The accelerated development in telecommunications and the need for higher transmission rates, to provide other services, such as multimedia, internet and remote conferecing, among others, has made optical cables the prime transmission media. These cables, using standard and NZD single-mode fibers, allow operating at high transmission rates, such as in SDH/SONET and ATM, among others, or multiple wavelength, such as WDM or DWDM systems. Its loose type design and the materials used in its manufacture provide full cable protection from bad weather. Indicated for outdoor deployment, such as urban trunking transport or subscriber access networks. Can be installed in duct runways or overhead lines, with steel cordage support. Dimensional Characteristics Designation CFOA-SM-DD-G CFOA-NZD-DD-G * Other lenghts can be provided on inquiry. per Basic Unit External Diameter (mm) Net Mass (kg/km) * Length per Coil (m) 04 to 12 02 9.5 72 6000 18 to 30 06 10.8 92 6000 36 06 11.5 106 6000 48 to 60 12 11.7 113 6000 72 12 12.4 128 6000 96 12 14.3 168 6000 120 12 16.2 215 6000 144 12 18.2 265 6000 Specification: ABNT NBR 14566, Telebrás 235.350.718 ANATEL Certification 40698-XXX256 / 40998-XXX256 / 41098-XXX256 Description: Fully dielectric optical cable with high tensile resistance. Gel-filled core for waterproofing. External black thermoplastic sheath. 7

OUTDOOR UNDERGROUND NETWORK Mechanical Characteristics CFOA-SM-DD-G / CFOA-NZD-DD-G Formation Maximum Installation Load Compression Resistance Minimum Bend Radius (mm) During Installation Installed Cable 4, 6, 8, 10, 12, 18, 24, 30,36, 48, 60, 72, 96, 120, 144 2 x weight of Cable per km. Minimum: 2000 1 x weight of Cable per km. Minimum: 1000 20 x External 10 x External Cable Formation Available from 04 to 144. CFOA-SM-DD-G / CFOA-NZD-DD-G Tensile Element Filler Protection Tube Central Dielectric Material Rip Cord 36 144 8

OUTDOOR UNDERGROUND NETWORK Cables CFOA-SM-DD-S / CFOA-NZD-DD-S Construction Characteristics Data Fiber Primary Fiber Jacket Number of * Cable Core Central Element Tensile Element Core Tie Types * Other lenghts can be provided on inquiry. CFOA-SM-DD-S Single Mode 4, 6, 8, 10, 12, 18, 24, 30, 36, 48, 60, 72, 96, 120 and 144 Hydro Expandable Material Non-metal Material Synthetic Synthetic Material Threads Black Polyethylene or Copolymer CFOA-NZD-DD-S Non Zero Dispersion Application: The accelerated development in telecommunications and the need for higher transmission rates, to provide other services, such as multimedia, internet and remote conferecing, among others, has made optical cables the prime transmission media. These cables, using standard and NZD single-mode fibers, allow operating at high transmission rates, such as in SDH/SONET and ATM, among others, or multiple wavelength, such as WDM or DWDM systems. Its loose type design and the materials used in its manufacture provide full cable protection from bad weather. Indicated for outdoor deployment, such as in urban trunking transport or subscriber access networks. Can be installed in duct runways or overhead lines, with steel cordage support. Dimensional Characteristics Designation CFOA-SM-DD-S CFOA-NZD-DD-S * Other lenghts can be provided on inquiry. Specification: ABNT NBR 14566 per Basic Unit External Diameter (mm) Net Mass (kg/km) * Length per Coil (m) 04 to 12 02 9.5 72 6000 18 to 30 06 10.5 85 6000 36 06 11.1 100 6000 48 to 60 12 11.5 103 6000 72 12 12.2 110 6000 96 12 14.0 150 6000 120 12 16.0 190 6000 144 12 18.0 235 6000 Description: Fully dielectric optical cable with high tensile resistance. Core waterproofed by hydro expandable material (dry core). External black corrugated thermoplastic sheath. 9

OUTDOOR UNDERGROUND NETWORK Mechanical Characteristics CFOA-SM-DD-S / CFOA-NZD-DD-S Formation Maximum Installation Load Compression Resistance Minimum Bend Radius (mm) During Installation Installed Cable 4, 6, 8, 10, 12, 18, 24, 30,36, 48, 60, 72, 96, 120, 144 2 x Weight of Cable per km. Minimum: 2000 1 x Weight of Cable per km. Minimum: 1000 20 x External 10 x External Cable Formation Available from 04 to 144. CFOA-SM-DD-S / CFOA-NZD-DD-S Tensile Element Filler Protection Tube Central Dielectric Material Waterproofing Ribbons Rip Cord 36 144 10

OUTDOOR UNDERGROUND NETWORK Cables CFOA-SM-DE-G / CFOA-NZD-DE-G FURUKAWA CFOA-SM-DE-G Application: The accelerated development in telecommunications and the need for higher transmission rates, to provide other services, such as multimedia, internet and remote conferencing, among others, has made optical cables the prime transmission media. These cables, using standard and NZD single-mode fibers, allow operating at high transmission rate, such as in SDH/SONET and ATM, among others, or multiple wavelengths, such as in WDM or DWDM systems. Its loose type design and the materials used in its manufacture provide full cable protection from bad weather. Indicated for outdoor deployment, such as urban trunking transport networks. Its polyamide jacket provides protection from ants and termites, making it suitable for directly buried installation. Construction Characteristics Data Fiber Primary Fiber Jacket Number of * Cable Core Central Element Core Tie Internal Sheath Internal Jacket Dimensional Characteristics Designation CFOA-SM-DE-G CFOA-NZD-DE-G Type * Other lenghts can be provided on inquiry. * Other lenghts can be provided on inquiry. CFOA-SM-DE-G Single Mode per Basic Unit External Diameter (mm) Net Mass (kg/km) * Length per Coil (m) 04 to 12 02 17.9 255 6000 18 to 36 06 17.9 258 6000 48 to 60 12 18.2 262 6000 72 12 18.8 278 6000 96 12 20.7 318 6000 120 12 22.6 365 6000 144 12 24.6 415 6000 Specification: ABNT NBR 14103, Telebrás 235.350.718 ANATEL Certification 41198-XXX256 / 41298-XXX256 / 41398-XXX256 Non Zero Dispersion 4, 6, 8, 10, 12, 18, 24, 30, 36, 48, 60, 72, 96, 120 and 144 Gel Non-metal Material Non Hygroscopic Material Black Polyethylene or Copolymer Polyamide (Nylon) CFOA-NZD-DE-G Black Polyethylene or Copolymer Description: Fully dielectric optical cable with high compression resistance, protected from ants and termites. 11

OUTDOOR UNDERGROUND NETWORK Mechanical Characteristics CFOA-SM-DE-G / CFOA-NZD-DE-G Formation Maximum Installation Load Compression Resistance Minimum Bend Radius (mm) During Installation Installade Cable 4, 6, 8, 10,12, 18, 24, 30, 36, 48, 60, 72, 96, 120, 144 1000 5000 20 x External 10 x External Cable Formation Available from 04 to 144. CFOA-SM-DE-G / CFOA-NZD-DE-G Internal Sheath Protection Tube Central Dielectric Element Filler Rip Cord Polyamide Internal Element (Nylon) 36 144 12

OUTDOOR UNDERGROUND NETWORK Cables CFOA-SM-ARE-G / CFOA-NZD-ARE-G CFOA-SM-ARD-G / CFOA-NZD-ARD-G Construction Characteristics Data Fiber Primary Fiber Jacket Number of * Cable Core Central Element Tensile Element CFOA-SM-ARD-G CFOA-NZD-ARD-G Single Mode or Single Mode With Non Zero Dispersion 4, 6, 8, 10, 12, 18, 24, 30, 36, 48, 60, 72, 96, 120 and 144 Gel Non Metal Material Core Tie Non Hygroscopic Material Internal Sheath - Protection from Rodents Corrugated Steel Tape Types Synthetic Fiber CFOA-NZD-ARE-G CFOA-NZD-ARE-G Single Mode or Single Mode With Non Zero Dispersion 4, 6, 8, 10, 12, 18, 24, 30, 36, 48, 60, 72, 96, 120 and 144 Gel Non Metal Material Non Hygroscopic Material Polyethylene or Copolymer Corrugated Steel Tape Black Polyethylene or Copolymer Black Polyethylene or Copolymer - Application: The accelerated development in telecommunications and the need for higher transmission rates, to provide other services, such as multimedia, internet and remote conferencing, among others, has made optical cables the prime transmission media. These cables, using standard and NZD single-mode fibers, allow operating at high transmission rate, such as in SDH/SONET and ATM, among others, or multiple wavelengths, such as in WDM or DWDM systems. Its corrugate steel tape shielding make it suitable for use in installations liable to rodent activity. Indicated for outdoor deployment, such as urban and interurban trunking transport or subscriber access networks, installed in underground tunnels or directly buried. Description: Fully dielecric optical cable protected by corrugated by steel armor. External black corrugated thermoplastic sheath. Dimensional Characteristics Designation CFOA-SM-ARE-G CFOA-NZD-ARE-G Dimensional Characteristics Designation CFOA-SM-ARD-G CFOA-NZD-ARD-G * Other lenghts can be provided on inquiry. * Other lenghts can be provided on inquiry. per Basic Unit per Basic Unit External Diameter (mm) External Diameter (mm) Net Mass (kg/km) Net Mass (kg/km) * Length per Coil (m) 04 to 12 02 15.0 215 4000 18 to 30 06 15.0 220 4000 36 06 16.0 240 4000 48 to 60 12 16.0 240 4000 72 12 16.7 270 4000 96 12 18.5 325 4000 120 12 20.5 390 4000 144 12 22.5 460 4000 * Length per Coil (m) 04 to 12 02 11.7 145 4000 18 to 30 06 12.2 165 4000 36 06 12.7 190 4000 48 to 60 12 13.0 200 4000 72 12 13.8 215 4000 96 12 15.7 265 4000 120 12 17.6 325 4000 144 12 19.6 385 4000 Specification: ABNT 03.086.01-026, 03.086.01-032 and Furukawa PT-0966 13

OUTDOOR UNDERGROUND NETWORK Mechanical Characteristics CFOA-SM-ARE-G / CFOA-NZD-ARE-G Formation Maximum Installation Load Compression Resistance Minimum Bend Radius (mm) During Installation Installed Cable 4, 6, 8, 10,12, 18, 24, 30, 36, 48, 60, 72, 96, 120, 144 1000 5000 20 x External 10 x External Field test showing cable attacked by rodents. CFOA-SM-ARD-G / CFOA-NZD-ARD-G Formation 4, 6, 8, 10,12, 18, 24, 30, 36, 48, 60, 72, 96, 120, 144 Maximum Installation Load 2 x Weight of Cable per km. Compression Resistance 1 x Weight of Cable per km. Minimum:1000 Minimum Bend Radius (mm) During Installation 20 x External Installed Cable 10 x External Cable Formation Available from 04 to 144 CFOA-SM-ARE-G / CFOA-NZD-ARE-G Internal Sheat Protection Tube Central Dielectric Material Rip Cord Filler Waterproofing Ribbons Corrugated Steel Tape 36 144 CFOA-SM-ARD-G / CFOA-NZD-ARD-G Rip Cord Protection Tube Central Dielectric Element Tensile Element Filler Waterproofing Ribbons Corrugated Steel Tape 36 144 14

OUTDOOR UNDERGROUND NETWORK Cables CFOA-SM-DPE-G / CFOA-NZD-DPE-G Construction Characteristics Data Primary Fiber Jacket Number of * Cable Core Tensile Element Central Element Core Tie External Jacket Types * Other lenghts can be provided on inquiry. CFOA-SM-DPE-G Single Mode 4, 6, 8, 10, 12, 18, 24, 30, 36, 48, 60, 72, 96, 120 and 144 Gel Synthetic Non-metal Material Non Hygroscopic Material Black Polyethylene or Copolymer Polyamide (Nylon) Black Polyethylene or Copolymer CFOA-NZD-DPE-G Non Zero Dispersion Application: The accelerated development in telecommunications and the need for higher transmission rates, to provide other services, such as multimedia, internet and remote conferencing, among others, has made optical cables the prime transmission media. These cables, using standard and NZD single-mode fibers, allow operating at high transmission rates, such as in SDH/SONET and ATM, among others, or multiple wavelength, such as WDM or DWDM systems. Its loose type design and the materials used in its manufacture provide full protection from bad weather. Indicated for outdoor deployment, such as in urban trunking transport networks lts polyamide jacket provides protection from ants and termites, and its external duct enhances even more the network s reliability, protecting it from accidental breakage by backhoes, for instance, making it suitable for directly buried installation. Dimensional Characteristics Designation CFOA-SM-DE-G CFOA-NZD-DE-G * Other lenghts can be provided on inquiry. per Basic Unit External Diameter (mm) Net Mass (kg/km) Cable Duct Cable Duct * Length per Coil (m) 04 to 12 02 10,0 25.5 84 210 5000 18 to 30 06 11,3 28.0 102 232 5000 36 06 12,0 29.5 116 245 5000 48 to 60 12 12,2 29.5 124 245 5000 72 12 13,0 31.5 141 278 4000 96 12 14,8 35.0 181 307 4000 120 12 16,7 38.0 229 336 3000 144 12 18,7 42.0 281 375 2500 Specification: ABNT NBR 14103, Telebrás 235.350.718 ANATEL Certification 41598-XXX256 / 41698-XXX256 / 41798-XXX256 Description: Fully dieletric optical cable with high tensile resistance. Core filled with waterproofing material, with thermoplastic jacket and a high-density polyethylene protection duct. 15

OUTDOOR UNDERGROUND NETWORK Mechanical Characteristics CFOA-SM-DPE-G / CFOA-NZD-DPE-G Formation Maximum Installation Load Compression Resistance Minimum Bend Radius (mm) During Installation Installed Cable 4, 6, 8, 10,12, 18, 24, 30, 36, 48, 60, 72, 96, 120, 144 1000 5000 15 x External 10 x External Duct sealer accessory around the Cable DPE. Cable Formation Available from 04 to 144. CFOA-SM-DPE-G / CFOA-NZD-DPE-G HDPE Duct Internal Sheath Internal Jacket Tensile Element Protection Tube Central Dielectric Material Filler Rip Cord 36 144 16

OUTDOOR UNDERGROUND NETWORK Cables CFOA-SM-DER-G (PPU)/CFOA-NZD-DER-G (PPU) CFOA-SM-DER-G (PFU)/CFOA-NZD-DER-G (PFV) Application: The accelerated development in telecommunications and the need for higher transmission rates, to provide other services, such as multimedia, internet and remote conferencing, among others, has made optical cables the prime transmission media. These cables, using standard and NZD singlemode fibers, allow operating at high transmission rates, such as in SDH/SONET and ATM, among others, or multiple wavelength, such as WDM or DWDM, systems. Its loose type design and the materials used in its manufacture provide full cable protection from bad weather. Indicated for outdoor deployment, such as in interurban trunking transport networks. CFOA-SM-DER-G (PPU) The polyamide jacket and layer of pultitruded elements (FRP) provide protection from ants and termites, making it suitable for directly buried installation. CFOA-SM-DER-G (PFV) The polyamide jacket and layer of fiberglass provide protection from rodents, ants and termites, making it suitable for directly buried installation. Description: Fully dieletric optical cable with high compression resistance, protected from insects and rodents. (PPU) Pultrade Protection. (PFV) Fiberglass Protection. Note.: Also available for duct installation (CFOA-SM-DDR-G / CFOA-NZD-DDR-G) through inquiry. Construction Characteristics Data Fiber Primary Fiber Jacket Number of * Cable Core Central Element Core Tie Internal Sheat Internal Jacket Protection from Rodents External Sheat Types * Other lengths can be provide on inquiry. Dimensional Characteristics Desigantion CFOA-SM-DER-G (PFU) CFOA-NZD-DER-G (PFV) * Other lengths can be provide on inquiry. CFOA-SM-DER-G (PPU) CFOA-NZD-DER-G (PPU) Single Mode or Single Mode with Non Zero Dispersion 4, 6, 8, 10, 12, 18, 24, 30, 36, 48, 60, 72, 96, 120 and 144 Gel Non-metal Material Non Hygroscopic Material Polyethylene or Copolymer Polyamide (Nylon) Layer of Fiber Reinforced Plastic Pultruded Element Black Polyethylene or Copolymer per Basic Unit Dimensional Characteristics Desigantion CFOA-SM-DER-G (PPU) CFOA-NZD-DER-G (PPU) External Diameter (mm) CFOA-NZD-DER-G (PFV) CFOA-NZD-DER-G (PFV) Single Mode or Single Mode with Non Zero Dispersion 4, 6, 8, 10, 12, 18, 24, 30, 36, 48, 60, 72, 96, 120 and 144 Gel Non-metal Material Non Hygroscopic Material Polyethylene or Copolymer Polyamide (Nylon) Layer of Fiberglass Net Mass (kg/km) Black Polyethylene or Copolymer * Length per Coil (m) 04 to 12 02 18.5 379 5000 18 to 36 06 18.5 383 5000 48 to 60 12 18.8 380 5000 72 12 19.5 395 4000 96 12 21,9 417 4000 120 12 23.1 460 4000 144 12 25.9 502 4000 * Other lengths can be provide on inquiry. per Basic Unit External Diameter (mm) Specification: ABNT 03.086.01-025, 03.086.01-031 and Furukawa PT-0511 ANATEL Certification 02399-XXX256 / 41498-XXX256 Net Mass (kg/km) * Length per Coil (m) 04 to 12 02 19.8 406 4000 18 to 36 06 19.8 410 4000 48 to 60 12 20.1 402 3000 72 12 20.9 419 3000 96 12 22.8 459 3000 120 12 24.7 506 2000 144 12 26.7 552 2000 17

OUTDOOR UNDERGROUND NETWORK Mechanical Characteristics CFOA-SM-DER-G / CFOA-NZD-DER-G (PPU and PFV) Formation Maximum Installation Load Compression Resistance Minimum Bend Radius (mm) During Installation Installed Cable 4, 6, 8, 10,12, 18, 24, 30, 36, 48, 60, 72, 96, 120, 144 1000 5000 20 x External 10 x External Field test showing cable attacked by rodents. Cable Formation Available from 04 to 144. CFOA-SM-DER-G (PFV) / CFOA-NZD-DER-G (PFV) Internal Sheath Rodent Protection (PFV) Filler Protection Tube Nylon Jacket 36 144 CFOA-SM-DER-G (PPU) / CFOA-NZD-DER-G (PPU) Rodent Protection (PPU) Nylon Jacket Central Dielectric Material Cladding Filler Internal Sheath 36 144 18

OUTDOOR OVERHEAD NETWORK Cables CFOA-SM-ASY-G / CFOA-NZD-ASY-G (PPU) CFOA-SM-ASY-RA-G / CFOA-NZD-ASY-RA-G CFOA - SM - AS120 - RA - G Construction Characteristics Data Primary Fiber Jacket CFOA-SM-ASY-G Single Mode Number of * 4, 6, 8, 10, 12, 18, 24, 30, 36, 48, 60, 72, 96, 120 and 144 Cable Core Gel Central Element Non-metal Material Core Tie Type Tensile Element External Jacket * Other lengths can be provided on inquiry. Theads of non Hygroscopic Material CFOA-NZD-ASY-G Non Zero Dispersion Aramine Synthetic Fiber Black Polyethylene or Copolymer With or Without Sire Stopping Application: The accelerated development in telecommunications and the need for higher transmission rates, to provide other services, such as multimedia, internet and remote conferencing, among others, has made optical cables the prime transmission media. These cables, using standard and NZD single-mode fibers, allow operating at high transmission rates, such as in SDH/SONET and ATM, among others, or with multiple wavelengths, such as WDM or DWDM, systems. Its loose type design and the materials used in its manufacture provide full protection from bad weather. Indicated for outdoor deployment, such as urban trunking transport or subscriber access networks, the cable is recommended for outdoor overhead, self-supporting installations. Description: Fully dielectric optical cable with high tensile resistance, waterproofed core and external thermoplastic jacket. Construction Characteristics Data Fibe Primary Fiber Jacket Types specification: ABNT NBR 14160, Telebrás 235.350.715 Furukawa PT-0352 ANATEL Certification 40798-XXX256 CFOA-SM-ASY-RA-G / CFOA-NZD-ASY-RA-G Single Mode Number od * 2, 4, 6, 8, 10 and 12 Supporting Element Fiber Reinforced Plastic (FRP) - Pultuted Element External Jacket Black Polyethylene or Copolymer * Other lengths can be provided on inquiry. Dimensional Characteristics Designation CFOA-SM-ASY-G CFOA-NZD-ASY-G CFOA-SM-ASY-RA-G CFOA-NZD-ASY-RA-G * Other lengths can be provided on inquiry. Fiber per Basic Unit External Diameter (mm) Net Mass (kg/km) * Length per Coil (m) 04 to 12 02 12.4 122 4000 18 to 30 06 13.4 143 4000 36 06 13.6 155 4000 48 to 60 12 14.0 160 4000 72 12 14.8 184 4000 96 12 16.5 225 4000 120 12 18.5 290 4000 144 12 20.5 345 4000 02 02 8.0 60 4000 04 04 8.0 60 4000 06 06 8.0 60 4000 08 08 8.5 70 3000 10 10 8.5 70 3000 12 12 8.5 70 3000 19

OUTDOOR OVERHEAD NETWORK Mechanical Characteristics CFOA-SM-ASY-G / CFOA-NZD-ASY-G Formation 4, 6, 8, 10,12, 18, 24, 30, 36, 48, 60, 72, 96, 120, 144 Span (m) 80 120 200 Maximum Instalattion Load Tensile Load 1.5 x cable weight/km 2 x cable weight/km 3 x cable weight/km Compression Resistance (kgf/10 cm) 1 x Weight of Cable per km. Minimum - 1000 N Projected Fluency After Installed for 20 years (%) Maximum 0.2 CFOA-SM-ASY-RA-G / CFOA-NZD-ASY-RA-G Formation 2, 4, 6, 8, 10,12 Span (m) 80 120 Maximum Instalattion Load Tensile Load 1.5 x cable weight/km 2 x cable weight/km Compression Resistance (kgf/10 cm) 1 x Weight of Cable per km. Minimum - 1000 N Projected Fluency After Installed for 20 years (%) Maximum 0.2 Cable Formation Available from 2 to 12. CFOA-SM-ASY-RA-G 12 Tensile Element External Jacket Rip Cord Protection Tube 12 Cable Formation Available from 04 to 12. CFOA-SM-ASY-RA-G 72 Dielectric Tensile Element Internal Sheath Filler Central Dielectric Material Protection Tube 72 20

OUTDOOR OVERHEAD NETWORK Cables CFOA-SM-LVY-S / CFOA-NZD-LVY-S Construction Characteristics Data Fiber Primary Fiber Jacket Number of * Cable Core Central Element Core Tie Tensile Element External Jacket Types * Other lengths can be provided on inquiry. CFOA-SM-LVY-S Singe Mode 4, 6, 8, 10, 12, 18, 24, 30, 36, 48, 60 and 72 CFOA-NZD-LVY-S Non Zero Dispersion Non Hydro Expanding Material Non-metal Material Ribbons of non Hygroscopic Material Aramine Synthetic Fiber Black Polyethylene or Copolymer With or Without Fire Stopping or Trailling-resistant Application: The accelerated development in telecommunications and the need for higher transmission rates, to provide other services, such as multimedia, internet and remote conferencing, among others, has made optical cables the prime transmission media. These cables, using standard and NZD single-mode fibers, allow operating at high transmission rates, such as in SDH/SONET and ATM, among others, or multiple wavelength, such as WDM or DWDM, systems. Its loose type design and the materials used in its manufacture provide full protection from bad weather. Indicated for outdoor deployment, such as urban trunking transport, teh cbale is recommended for utdoor overhead, wide-span, self-supporting installations or on power transmission pylons. Dimensional Characteristics Designation CFOA-SM-LVY-S CFOA-NZD-LVY-S * Other lengths can be provided on inquiry. Fiber per Basic Unit Specification: ABNT 03.086.01-20 y Furukawa PT-949 External Diameter (mm) Net Mass (kg/km) * Length per Coil (m) 04 to 12 02 12.9 158 4000 18 to 30 06 13.6 171 4000 36 06 13.8 175 4000 48 to 60 12 14.9 176 4000 72 12 15.5 194 4000 Description: Fully dieletric optical cable with high tensile resistance, waterproofed core and external thermoplastic jacket. 21

OUTDOOR OVERHEAD NETWORK Mechanical Characteristics CFOA-SM-LVY-S / CFOA-NZD-LVY-S Formation Span (m) Maximum Installation Load N Tensile Load Compression Resistance (kgf/10 cm) Projected Fluency after Installed for 20 years (%) 4, 6, 8, 10,12, 18, 24, 30, 36, 48, 60, 72 300 400 500 5 x Cable weigth/km 6 x Cable weigth/km 7.5 x Cable weigth/km 1 x Weight ot cable/km. Maximum 0.2 Cable Formation Avaialable from 2 to 72. CFOA-SM-LVY-S / CFOA-NZD-LVY-S Dielectric Tensile Element Water Proof Threads Internal Sheath Filler Central Dielectric Material Protection Tube 36 External Sheat Dielectric Tensile Element Water Proof Threads Internal Sheath Filler Central Dielectric Material Protection Tube 72 22

OUTDOOR OVERHEAD NETWORK Cable OPGW-SM / OPGW-NZD Construction Characteristics Data Types OPGW-SM OPGW-NZD Fiber Single Mode Non Zero Dispersion Primary Fiber Jacket Number of * 6, 12, 18, 24, 36 and 48 Spacer Slotted Steel Protection Tube Aluminum External Wires * Other lengths can be provided on inquiry. Steel Wire Covered With Aluminum and/or Steel-aluminum Application: The accelerated development in telecommunications and the need for higher transmission rates, to provide other services, such as multimedia, internet and remote conferencing, among others, has made optical cables the prime transmission media. These cables, using standard and NZD single-mode fibers, allow operating at high transmission rates, such as in SDH/SONET and ATM, among others, or multiple wavelength, such as WDM or DWDM, systems. Its loose type design and the materials used in its manufacture provide full protection from bad weather. Indicated for outdoor deployment, such as urban trunking transport, teh cbale is recommended for utdoor overhead, wide-span, self-supporting installations or on power transmission pylons. Description: Steel wire and/or steel-aluminium alloy lightning shielded cable with and optical fiber core. Dimensional Characteristics Characteristics Aluminum-Steel Tape Unit *OPGW 47 mm² Specification: Furukawa PT-0246-47 mm² / PT-0246-54 mm² PT-1037-63 mm² / PT-0436-96 mm² PT-1069-79 mm² *OPGW 54 mm² *OPGW 63 mm² *OPGW 79 mm² *OPGW 96 mm² nº / mm 9 / 2.59 11 / 2.5 12 / 2.59 7 / 3.78 3 / 3.9 Aluminum Alloy Wires nº / mm - - - - 5 / 3.9 Aluminum Tube Outer Diameter mm 5.0 6.5 7.5 5.0 6.5 Cable Outer Diameter mm 10.2 11.5 12.7 12.6 14.3 Rated Net Mass kg / km 360 432 508 565 470 * Other lengths can be provided on inquiry. Electrical and Mechanical Characteristics Characteristics DC Electrical Resistance at 20ºC Final Linear Expansion Coefficient Steel-Aluminum Wire Conductivty Final Elastic Modulus Breaking Load Maximum Short Circuit Current Capacity Maximum Short Circuit Current Temperature Unit OPGW 47 mm² OPGW 54 mm² OPGW 63 mm² OPGW 79 mm² OPGW 96 mm² Ω/km 1.03 0.74 0.64 0.75 0.34 1/ºC x 10 12.6 12.6 14.1 13.3 16.7 % IACS 20.3 20.3 20.3 20.3 20.3 kgf / mm² 16,500 16,500 13,520 15,030 10,300 kgf 5,600 6,600 7,770 8,950 5,700 ka².s -6 11 21 33 23 70 (4,7 KA x 0,5s) (6,5 KA x 0,5s) (33 KA x 0,5s) (6,8 KA x 0,5s) (11,8 KA x 0,5s) ºC 180 180 180 180 180 23

OUTDOOR OVERHEAD NETWORK OPGW Cable Formation Available from 6 to 48. OPGW 54 mm² - 36 Fibras Configuration of the Basic Unit (06 to 08 fibers) Central Element Configuration of the Core Basic Unit Aluminum Spacer Aluminum Tube Steel-Aluminum Wires Basic Unit Aluminum Tube Aluminum Spacer 24

OUTDOOR PLANT Cables CFOI-SM-MF / CFOI-NZD-MF CFOI-SM-UB / CFOI-NZD-UB Construction Characteristics Data Fiber Primary Fiber Jacket Sencondary Jacket Types CFOI-SM-MF CFOI-NZD-MF Single Mode or Single Mode with Non Zero Dispersion Thermoplastic CFOI-SM-UB CFOI-NZD-UB Number of * 2, 4, 6, 8, 10 and 12 18, 24, 30, 36, 48, 60, 72, 96, 120 and 144 Cable Core Single Fiber Cords Single Mode or Single Mode with Non Zero Dispersion - Basic Units with 06 to 12 per Unit Central Element Dielectric Material Dielectric Material Core Tie External Jacket Non Hygroscopic Material Blue Fire Stopping Thermoplastic Non Hygroscopic Material Blue Fire Stopping Thermoplastic Application: The accelerated development in telecommunications and the need for higher transmission rates, to provide other services, such as multimedia, internet and remote conferencing, among others, has made optical cables the prime transmission media. These cables, using standard and NZD single-mode fibers, allow operating at high transmission rates, such as in SDH/SONET and ATM, among others, or multiple wavelength, such as WDM or DWDM, systems. With fire stopping characteristics, these cables are indicated for indoor installations at telephone central offices and commercial, industrial or residential buildings where fire-stopping safety is required. Description: Fully dielectric optical cable formed by optical cords or basic units, with fire stopping characteristics. Dimensional Characteristics Designation CFOI-SM-MF CFOI-NZD-MF CFOI-SM-UB CFOI-NZD-UB 02 to 06 * Other lengths can be provided on inquiry. per Basic Unit Specification: Telebrás 235.350.712 y Furukawa PT-0696 ANATEL Certification 41898-XXX256 / 41998-XXX256 - External Diameter (mm) 12.0 Net Mass (kg/km) 150 * Length per Coil (m) 2000 08 to 12-18.0 290 2000 18 to 30 06 10.8 102 2000 36 06 11.3 118 2000 48 to 60 12 11.6 125 2000 72 12 12.4 145 2000 96 12 14.3 185 2000 120 12 16.2 238 2000 144 12 18.2 292 2000 25

OUTDOOR OVERHEAD NETWORK Mechanical Characteristics CFOI-SM-MF / CFOI-NAD-MF and CFOI-SM-UB / CFOI-NZD-UB Formation 4, 6, 8, 10, 12,18, 24, 30, 36, 48,60, 72, 96, 120, 144 Maximum Installation Load 0.2 x Cable Weight per km Compression Resistance 1000 Minimum Bend Radius (mm) During Installation 20 x External Installed Cable 10 x External Cable Formation Available from 04 to 144. CFOI-SM-MF / CFOI-NZD-MF Outer Jacket Cords Central Dilectric Element 6 CFOI-SM-UB / CFOI-NZD-UB Outer Sheath Protection Tube Central Dielectric Element 36 144 26

INDOOR OVERHEAD NETWORK Cord COA-SM-MF / COA-NZD-MF Application: The accelerated development in telecommunications and the need for higher transmission rates, to provide other services, such as multimedia, internet and remote conferencing, among others, has made optical cables the prime transmission media. These cables, using standard and NZD single-mode fibers, allow operating at high transmission rates, such as in SDH/SONET and ATM, among others, or multiple wavelength, such as WDM or DWDM, systems. With fire stopping characteristics, these cables are indicated for indoor installations at telephone central offices and commercial, industrial or residential buildings where fire-stopping safety is required. Description: Cord cable formed by tight type insulated fiber, dielectric tensile element and fire stopping thermoplastic outer sheath. Construction Characteristics Data Fiber Primary Fiber Jacket Secondary Jacket Tensile Element Outer Jacket Types Dimensional Characteristics Data COA-SM-MF 01 COA-NZD-MF * Other lengths can be provided on inquiry. Mechanical Characteristics Cords: COA-SM-MF / COA-NZD-MF Formation Single Fiber Cord Maximum Installation Load COA-SM-MF Single Mode Thermoplastic Non Metallic Material, Distributed Over the Outer Jacket (Synthetic Fiber) Blue Fire Stopping Thermoplastic Specification: ABNT NBR 14106 and Telebrás 235.350.709 External Diameter (mm) COA-NZD-MF Non Zero Dispersion Thermoplastic Non Metallic Material, Distributed Over the Outer Jacket (Synthetic Fiber) Green Fire Stopping Thermoplastic Net Mass (kg/km) * Length per Reel (m) 3.0 8.5 250, 500, 750 01 3.0 8.5 250, 500, 750 Minimum Breaking Traction Minimum Bend Radius (mm) Without Incresing Attenuation Above 0.1 db 30 200 50 mm 27

INDOOR NETWORK Cord Formation COA-SM-MF Outer Jacket Dielectric Tensile Element Secondary Jacket Fiber 28

General Informations of Cables Characteristics Characteristics Tipical Attenuation at 1310 nm Maximum Attenuation at 1310 nm 0.37 - Tipical Attenuation at 1550 nm db/km 0.20 0.22 Maximum Attenuation at 1550 nm 0.23 0.25 Chromatic Dispersion at 1310 nm 3.0 - Chromatic Dispersion from 1285 nm to 1330 nm 3.5 - Chromatic Dispersion at 1550 nm 18 - ps/nm.km Chromatic Dispersion from 1525 to 1575 nm 19 - Chromatic Dispersion at 1530 nm - 1.0 Chromatic Dispersion at 1565 nm - 6.0 Dimensional Characteristics Characteristics Diameter of Shell Unit µm Single Mode Fiber (SM) Non Zero Dispersion Single Mode Fiber (NZD) 125 ± 2 125 ± 1 Diameter of Jacket µm 245 ± 10 245 ± 10 Modal Field/Shell Concentricity Error µm 0.8 0.8 Non Circularity of Shell % 1 1 Unit Single Mode Fiber (SM) Non Zero Dispersion Single Mode Fiber (NZD) 0.35 0.4 Fiber/ Jacket Concentricity Error µm 12 12 29

Connectors Extension Cord and Mechanical Characteristics SM/NZD Connector General The extensions and cords supplied by Furukawa are produced to the strictest Brazilian and International standards. The figures for return and insertion loss are the characteristics that define the high performance of these products. The higher the return loss lower and the insertion loss, the better the system s optical characteristics will be. Accordingly, assembling these devices in clean environments is of utmoust importance, with controlled temperature and moisture and with polishing equipment suitable for meeting the highest quality standards. Characteristic Type of Polishing Return Loss (db) Insertion Loss (db) Operation Range (ºC) Mechanical Life Tensile Resistance Applicable Models * * Other types of connectors are assembled to order. For instance, ST, E2000, etc. Standard Lengths Standard Lengths of single fiber cords/extensions with connectors. 1,5 m; 2,5 m; 7 m; 15 m and 20 m. (Other lengths on inquiry) Fiber Single Mode or Single Mode with Non Zero Dispersion PC SPC UPC APC 25 35 45 60 Average 0.3 Maximum 0.5-10 to 70 > 500 insertions 100 HMS10A SC, FC SC, FC SC, FC 30

Installation Method Directly Buried Deployment The installation methods of Furukawa cables are shown below. Directly Buried - Manual Process. Directly Buried - Plow Mechanized Process Using Machine. Concrete direct covering on DPE-G Cable. Installing in Rocky Soil. DPE-G Cable after accident with backhoe. Not undamaged Core. 31

Installation Method Underground Duct Installation Cables for ducts (DD-G or DD-S) Overhead Installation OPGW Overhead Cable installed on a Transmission Line Pylon. ASBO-RA-G Overhead Cable with Furukawa Acessory. 32