Universal input/output controller

Similar documents
Installation hole (4.2mm) Push. Ambient daylight threshold. 8 hours manual on

LED DALI MC+ Switch Input Module - User Manual

Dry Contact Sensor DCS15 User Manual

CB-030S Circuit Board

Electrical devices may only be mounted and connected by electrically skilled persons.

Dry Contact Sensor

LED wdali MC Switch Input Modul Set - User Manual

BV4115. RF Packet Transmitter. Product specification. February ByVac 2007 ByVac Page 1 of 5

4- CHANNEL RGBW DIMMER RE KNT RGB

Remote Control Learn Button Receiver Input Connections

Maxon Motor & Motor Controller Manual

Damocles 2404i Manual

Operating Instructions

idcv Isolated Digital Voltmeter User Manual

Operation and installation manual KNX ENO 636 secure. Application. 1. Installation and connection

Specification for a communicating Panelboard system to monitor, control and maintain LV electrical installations

Laboratory: Introduction to Mechatronics. Instructor TA: Edgar Martinez Soberanes Lab 1.

GANTOM iq AND iqx USER GUIDE

Dry Contact Sensor. Communications cable - RJ-45 jack to sensor using UTP Cat 5 wire. Power source: powered by the unit. No additional power needed.

INSTALLATION INSTRUCTIONS

AF4000 MOD-1 OEM Production Line Troubleshooting Guide

USER MANUAL HIGH INTERCEPT LOW NOISE AMPLIFIER (HILNA TM ) V1

High Power, Super-Fast SPST switch

VM1AT-R1 INDUSTRIAL MICROCONTROLLER

Technical Documentation

LINE POWER SUPPLIES Low-Loss Supplies for Line Powered EnOcean Modules

Damocles 1208 MANUAL. Damocles Damocles 1208 Manual. Input status LED indicators. Inputs Not connected

Processors with Sub-Microsecond Response Times Control a Variety of I/O. *Adapted from PID Control with ADwin, by Doug Rathburn, Keithley Instruments

Supervision Relay SR100

Application Note AN-2097 Evaluation Kit for the S7500 CW Tunable Laser

TC 60 THERMOCOMPUTER TC 60. prog. start stop. Operating Instructions

Experiment 7 Digital Logic Devices and the 555-Timer

Operating Instructions

RiverSurveyor S5/M9 & HydroSurveyor Second Generation Power & Communications Module (PCM) Jan 23, 2014

CM5530 GENERAL DESCRIPTION APPLICATIONS TYPICAL APPLICATION CIRCU. Rev.1.0 0

WS-400 BASE STATION FOR WIRELESS INTERCOM WITH FOUR TX/RX MODULES USER MANUAL

ANALOG-TO-DIGITAL (ADC) & DIGITAL-TO-ANALOG (DAC) CONVERTERS

GANTOM iq AND iqx USER GUIDE

7.3 3 CENTRAL PANEL DISPLAY SYSTEM 3.1 GENERAL 3.2 CONTROLS VEMD COMPLEMENTARY FLIGHT MANUAL

Experiment 7 Digital Logic Devices and the 555-Timer

IntesisBox IS-IR-KNX-1i v1.0. User's Manual Issue Date: 06/2017 r1.0 eng

KELOX room thermostats - KM690D Digital-Standard/ KM690U Digital-Control

Flash Image Rotator Web Part

Figure 1: View, connection compartment closed

High-Power Solid-State Device, p/n EDR84102/x. 100VDC at 100 amperes 1-Form A, SPST-N.O. (normally opened) Solid-State Relay/Switch

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CS406-R51E

RZ251W. Remote Sensing & Zoning Installation Guide. Quick Reference. Wireless Range

Security Exercise 12

OPERATING FEATURES & FUNCTIONS

SISTEMA ELEVATÓRIO ETV 460A

VIP-200. Point to Point Extension Configuration Quick Start Guide. Video over IP Extender and Matrix System

A Geno Technology, Inc. (USA) brand name. Orbital Shaker. Cat. No. BT909, BT926, BT

INSTALLATION INSTRUCTIONS

Owner s Manual Installation and Operating Instructions

DEI 1028 Voltage Clamping Circuit

UPB Lighting, see model # list below

1.12 Equipment Manager

2015 Chevrolet Corvette Corvette Service Manual Body Systems Vehicle Access Repair Instructions Document ID:

For over 25 years Mtroniks have been at the forefront of electronic speed control design and manufacture for the hobby industry.

Mobile LightSync Link App Programing Guide Revision 2

IntesisBox TO-RC-KNX-1i v1.3

LCN Remote Control. Perfection. High-End Building Management. Remote Control

Wireless Bridge Module for DXR2.E

ELEC 7250 VLSI TESTING. Term Paper. Analog Test Bus Standard

CUSTOMER PORTAL. Floorplan Management

DRAN30 SERIES MODEL LIST SPECIFICATION. GENERAL Characteristics Conditions min. typ. max. unit FEATURES. EFF. (min.) EFF. (typ.

E-Learning, DC drives DCS800 Hardware Options, part 1 Size D1 D4. ABB Group February 2, 2010 Slide 1 DCS800_HARDWARE_OPTIONS_01R0101

Guide for ESP32-Sense Development Kit

ELECTRIC ROTATIONAL ACTUATOR TYPE ESO-07

SFDMDA4108F. Specifications and Applications Information. orce LED Driver. Mass: 9 grams typ. 03/30/11. Package Configuration

4 wires. AUDIO & VIDEO TERMINALS for TL door phone systems User manual. Audio. 7" Videoadvanced. 7" Video

IntesisBox PA-RC-KNX-1i v1.2

USER S OPERATING MANUAL FOR DIGITAL TEMPERATURE CONTROLLER

RF MONO 8.2MHz RF MONO HIGH FREQUENCY PCB CONNECTION. Please see the last section in this document. FOREWARDS

APPLICATION NOTE Sales & Application DEWESoft Slovenia

XDS Pro-4 Network Data Sheet

Operating manual wireless hand wheel HBG 220-RF

ADVERTISEMENT FOR PROPOSALS. Publish Tuesday November 14, 2017 Wisconsin State Journal

Martel LC-110H Loop Calibrator and HART Communications/Diagnostics

SHORT CODE. Short Code

Experiment 6 Electronic Switching

SPECIFICATIONS : - SAFETY INSTRUCTION : 1. DISPLAY TYPE : Dual 4- Digit 7 Segment LED 4 Digit Bright Red (PV) 4 Digit Luminous Green (SV)

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION

TROUBLESHOOTING GUIDE

Modular Intruder Alarm System MAS-800

PaperStream IP (TWAIN) change history

Electrical devices may only be mounted and connected by electrically skilled persons.

OV5640 Camera Board (A) USER MANUAL

OV5640 Camera Board (B) USER MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS. Viron Connect Pool Viron Cartridge Filter and Spa Controller

TUTORIAL I ECE 555 CADENCE SCHEMATIC SIMULATION USING SPECTRE

EE 311: Electrical Engineering Junior Lab Phase Locked Loop

PaperStream IP (TWAIN x64) change history

Omni-Bus Interface Translator Rev 2. Reference Manual

SolarEdge. Immersion Heater Controller Installation Guide. For Europe, APAC & South Africa Version 1.6

GSatMicro Operations Manual

True Double Pole, Single Through (DPST or 2 Form A+B) Connectable as a SPDT and others DPST Solid-State Relays

Configuring the MSNSwitch For the LAN-Cell 3

NanoScan v2 Readme Version 2.7. Change log. v2.7 - Added information for new product Pyro/9/5-MIR.

karma UK Sales: RETAIL Price List - Valid From January 2017

Transcription:

Embedded autmatin equipment (Shanghai) Limited Rm 305. Twer B.NO.18Talin rad Pudng District, Shanghai Phne: +86-21-51090839/50750355, fax: +86-21-50758598, e-mail: sales@stammkn.cm Universal input/utput cntrller Universal 8 channel input/utput device is the nly prduct n the market with pssibility t switch each channel frm input t utput therefre making the device extremely flexible. It makes life fr installers and system designers mre accurate and headache-free. ENG - Data sheet Issue date 10.10.2013 Applicatin Lighting, lad cntrl, security Each f 8 prts can be used as: - Analg input 0-30V - Binary input 0/30 V - Impulse cunter - Shrt/lng press key - Step dimmer - Open cllectr utput e.g. fr external relay mdule cnnectin Types f prduct Universal 8 channel IO mdule UIO82M Standards and nrms cmpliance EMC: PCT EN61000-6-1 EN61000-6-3 Certificate Technical data: Pwer supply: Pwer cnsummatin: 0.25W 29V DC frm KNX/EIB bus Interface: KNX/EIB 1 Input/utput channels 8

Inputs Cunt up t 8 Type Analg input 0-30V Binary input 0/30 V Impulse cunter Shrt/lng press key Step dimmer Outputs Cunt up t 8 Type Digital Maximal current n utput 380mA Cnnectins: KNX/EIB Bus Cnnectin Terminal 0.8mm2 IO Clamp, 1.5mm2 Operating elements LED 1 - Activity Enclsure: Material: Plyamide Clr: Gray Dimensins: 36(W)x91(H)x56(L) mm Usage temperature: 0C... +45C Strage temperature: -15C... +55C Weight: 50g Warranty: 2 years Relative Humidity: 10...95 % withut cndensatin Cautin Security advice The installatin and assembly f electrical equipment may nly be perfrmed by skilled electrician. The devices must nt be used in any relatin with equipment that supprts, directly r indirectly, human health r life r with applicatin that can result danger f peple, animals r real value Munting advice The devices are supplied in peratinal status. The cables cnnectins included can be clamped t the husing if required. Electrical cnnectin The devices are cnstructed fr the peratin f prtective lw vltage (SELV). Grunding f device is nt needed. When switching the pwer supply n r ff, pwer surges must be avided.

1. Cnnectin diagrams 1.1. External relays

1.2. Binary push-buttn

1.3. Vltage sensr

2. Default settings T reset the device t default settings, press and hld prgramming buttn fr mre than 10 secnds. Prgramming LED will blink several times after releasing the prgramming buttn. The device will restart autmatically after the reset is cmplete. 3. Default state f the device Factry-new devices have the physical address 1.1.255, n grup addresses. 4. ETS cnfiguratin 4.1. General settings Start-up delay (secnd) delay n device bt up Heartbeat send interval [Disabled.. 10minutes] time interval after which the device sends the telegram infrming that it is alive

4.2. Channel settings Output Open drain / Binary Input Binary edge detect Input Binary shrt/lng press Input Binary impulse cunter Input Step dimmer Input Analgue vltage sensr (0 30 V) 4.2.1. Output Open drain / Binary Output mde [Nrmally pen / Nrmally clse] default utput mde nrmally pen (0 ff, 1 - n), nrmally clse (0 n, 1 - ff) Status bject mde [Nrmal / Inverted] mde f the status bject Start-up value [0 / 1 / last knwn value] start-up value fr the bject On-timer [Disabled / Enabled] defines if the n timer is enabled Off-timer [Disabled / Enabled] defines if the ff timer is enabled Additinal bject additinal lgic bject fr the utput Lgical OR ne f bject r lgical bject shuld be 1 fr actin t perfrm Lgical OR initial value [0 / 1 / Lat knwn value]

Object A Object B Result 0 0 0 1 0 1 0 1 1 1 1 1 Lgical AND bth bject and lgical bject shuld be equal fr actin t perfrm Lgical AND initial value [0 / 1 / Lat knwn value] Object A Object B Result 0 0 0 1 0 0 0 1 0 1 1 1 Fault detectin status bject fr fault detectin (e.g. when there is n current flwing frm pen drain while it s status is OPEN) Fault detectin bject mde [Nrmal (0 n errr, 1 errr ) / Inverted (0 errr, 1 n errr)]

Output On / Off Timer In case On r Off timer is enabled in Output cnfiguratin, apprpriate submenu appears. Delay time [130 ms.. 10 m] delay time fr changing the status f the bject Delay multiplier [x1.. x10] e.g. if delay is set t 10 min and multiplier x5, the delay will be 50 min Reactin t ff/n telegram [Ignre / Set bject t n state] actin t perfrm n n/ff telegram

4.2.2. Input Binary edge detect Rising edge [D nthing / Send 0 / Send 1 / Tggle value] actin t perfrm n rising edge Falling edge [D nthing / Send 0 / Send 1 / Tggle value] actin t perfrm n falling edge

4.2.3. Input Binary shrt/lng press Shrt press [Send 0 / Send 1, Tggle value] Actin n shrt press Lng press [Send 0 / Send 1, Tggle value] Actin n lng press Lng press delay [250 ms.. 10 s] delay interval t detect lng press

4.2.4. Input Binary impulse cunter Cunter pulse edge [Rising edge / Falling edge / Bth] - which part f the impulse t cunt Cunter directin [Up / Dwn] directin f the cunter Number f pulses per cunter increment [1..100] number f pulses fr cunter increase by 1 (e.g. 10 pulses infrms abut 1 liter f water increase cunter by 1) Cunter step per each pulse [1..100] cunter step fr each pulse (e.g. 1 pulse means 10 liters f water increase cunter by 10) Send telegram n cunter update [Disabled / Enabled] send telegram int the bus n each cunter update Peridical send interval [10 s.. 10 min] time interval after which t send the reading f pulses t the bus Input Analgue vltage sensr (0 30 V) Input Analgue vltage sensr (0 30 V) Input Analgue vltage sensr (0 30 V)

4.2.5. Input Step dimmer Dimmer step [1..127] value n which the brightness will be changed n each step Dimmer ON preset (0 use previus) [0..255] preset when dimmer is switched ON

4.2.6. Input Analgue vltage sensr (0-30V) Object type [Analg vltage sensr /Binary vltage sensr] type f input vltage. In case f Analg vltage sensr, the fllwing parameters appear: Analg bject type [Scale (0-100%/1 Byte / Vltage (2 Byte)] mde f the status bject Minimum vltage minimum vltage value Maximum vltage maximum vltage value Send mde (Value change / Timer) when t send the telegram int the bus Value change threshld (0.1V step) (1..100) determine when the value is changed

In case f Binary vltage sensr, the fllwing parameters appear: Lw/high threshld (1..30) threshld level belw which the value is determined as Lw, and abve it is High Hysteresis (2..30) level f hysteresis during which value keeps unchanged Output value (Lw=0; High=1 / Lw=1; High=0) utput value in the bus

4.3. Lck bject Fr each f the prts yu can lck the bject. Input 1 Lck [1 bit] sending 1 disables 1 channel, sending 0 enables it again Input 8 Lck [1 bit] - sending 1 disables 8 channel, sending 0 enables it again