Specifications. S&C Cypoxy Insulators. Indoor and Outdoor Distribution (4.8 kv through 46 kv) Conditions of Sale

Size: px
Start display at page:

Download "Specifications. S&C Cypoxy Insulators. Indoor and Outdoor Distribution (4.8 kv through 46 kv) Conditions of Sale"

Transcription

1 Indoor and Outdoor Distribution (.8 kv through kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: INCLUSIONS: S&C Cypoxy Insulators are manufactured utilizing S&C s proprietary Cypoxy cycloaliphatic epoxy resin system. The Cypoxy material is nontracking, selfscouring, and nonweathering. The standard color for S&C Cypoxy Insulators is gray. No other colors are available. S&C Cypoxy Insulators are furnished with embedded aluminum inserts, threaded to accommodate standard galvanized bolts. As noted in the appropriate tables on pages through, the sets of inserts at the two ends of S&C Insulators are furnished in one of two standard configurations: either in-line or with a 90 offset relative to each other. EXCLUSIONS: S&C Cypoxy Insulators do not include mounting hardware. How to Order 1. Obtain the catalog number of the desired Cypoxy Insulator from the tables on pages through.. Obtain the suffix letter of spacer-adapters, if desired, from the table on page 7. December 19, 011 S&C Electric Company Specification Bulletin

2 OUTDOOR STATION POST INSULATORS1 Configuration Rating, kv Nominal Height, Creepage mm/kv Strength, Pounds3 Page Reference for Dimensional Information 1. 1 (5) 1M\, (9) PA-75R1 8 5/3.5h (35) Z\v (7) PA-753R (57) 37C\, (99) PA-75R1 8 inserts each end, 30 (7 mm) Z\x tapped holes 50 (559) 57C\, (157) PA S&C Cypoxy station post insulators meet or exceed the electrical and mechanical-strength requirements established in ANSI Standard C9.9 (1983) for porcelain standard-strength station post insulators. Calculated at nominal voltage. 3 To attain their rated cantilever strengths, Cypoxy Insulators must be base of the insulator. Furthermore, the mounting surface must be free of protrusions, such as lumps from galvanizing, to prevent cracking of the insulator when mounting bolts are tightened. These insulators have tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter (marked Base ) must be oriented toward the mounting surface. h Applicable at 3.5 kv where the leakage distance to ground meets user s requirements. S&C Specification Bulletin

3 INDOOR-OUTDOOR INSULATORS Configuration Rating, kv Nominal Height, Creepage mm/kv1 Strength, Pounds Page Reference for Dimensional Information 90 Offset 1. 1 (171) 1Z\, (359).9 0 PA-7191d 9 inserts each end, Z\v0 (57 mm) bolt spacing; Z\,0 1 3 B\,0 tapped holes (5) Z\, (13).5 00 PA-719d (35) Z\v (7) PA-753R1dfa 9 inserts each end, 30 (7 mm) Z\x tapped holes Specialty l 5 (70) (70) PA insert each end, centered; Z\x C\,0 tapped hole 1 Calculated at nominal voltage. To attain their rated cantilever strengths, Cypoxy Insulators must be base of the insulator. Furthermore, the mounting surface must be free of protrusions, such as lumps from galvanizing, to prevent cracking of the insulator when mounting bolts are tightened. l This insulator serves as a blade spacer in S&C Regulator Bypass Switches XL. When used alone its nominal rating is 00 volts. d This insulator has tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter (marked Base ) must be oriented toward the mounting surface. f For indoor use only, when applied at 3.5 kv. a Supersedes PA When replacing Insulator PA-7193, specify one Spacer-Adapter S-85. S&C Specification Bulletin

4 INDOOR INSULATORS Configuration Rating, kv Nominal Height, Creepage mm/kv1 Strength, Pounds Page Reference for Dimensional Information.8 0 M\, (1) PA-71d Bus 1 insert each end, centered; Z\x C\,0 tapped hole Z\, (308) PA-713d 90 Offset (17) 7 (197) PA-71 inserts each end, 30 (7 mm) Z\x tapped holes (330) PA-71d Z\v (159) 1Z\v PA (70) PA-7183 inserts each end, 0 (51 mm) bolt spacing and inserts each end, 1C\,0 (35 mm) bolt spacing ; C\, 1 3 B\,0 tapped holes (5) Z\, (). 00 PA Calculated at nominal voltage. To attain their rated cantilever strengths, Cypoxy Insulators must be base of the insulator. Furthermore, the mounting surface must be free of protrusions, such as lumps from galvanizing, to prevent cracking of the insulator when mounting bolts are tightened. PA-705 has inserts at each end with a -inch bolt spacing. d This insulator has tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter must be oriented toward the mounting surface. TABLE CONTINUED v S&C Specification Bulletin

5 INDOOR INSULATORSContinued Configuration Rating, kv Nominal Height, Creepage mm/kv1 Strength, Pounds3 Page Reference for Dimensional Information inserts, 0 (51 mm) bolt spacing, C\,0 1 3 B\,0 tapped holes 1 insert, center; B\, M\,0 tapped hole PA Z\v PA (70) PA inserts, 0 (51 mm) C\,0 1 3 B\,0 tapped holes (1) Z\x (57).9 00 PA inserts, 0 (51 mm) C\,0 1 3 B\,0 tapped holes 1 insert, center; B\, M\,0 tapped hole PA Z\v PA (70) PA inserts, 0 (51 mm) C\,0 1 3 B\,0 tapped holes (1) Z\x (57).9 00 PA Calculated at nominal voltage. To attain their rated cantilever strengths, Cypoxy Insulators must be base of the insulator. Furthermore, the mounting surface must be free of protrusions, such as lumps from galvanizing, to prevent cracking of the insulator when mounting bolts are tightened. 3 These insulators have tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter (marked Base ) must be oriented toward the mounting surface. TABLE CONTINUED v S&C Specification Bulletin

6 INDOOR INSULATORSContinued Configuration Rating, kv Nominal Height, Creepage mm/kv1 Strength, Pounds3 Page Reference for Dimensional Information inserts, 0 (51 mm) C\,0 1 3 B\,0 tapped holes PA Z\v PA (70) PA inserts, 0 (51 mm) C\,0 1 3 B\,0 tapped holes inserts, 0 (51 mm) C\,0 1 3 B\,0 tapped holes 5 0 (1) Z\x (57).9 00 PA PA Z\v PA (70) PA inserts, 0 (51 mm) C\, 1 3 B\,0 tapped holes (1) Z\x (57).9 00 PA Calculated at nominal voltage. To attain their rated cantilever strengths, Cypoxy Insulators must be base of the insulator. Furthermore, the mounting surface must be free of protrusions, such as lumps from galvanizing, to prevent cracking of the insulator when mounting bolts are tightened. 3 These insulators have tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter (marked Base ) must be oriented toward the mounting surface. S&C Specification Bulletin

7 SPACER-ADAPTERS Illustration Description Height, For use with Insulator Galvanized stamped steelfor use in adapting 30 (7 mm) insulator-bolt spacing (for Z\x0 13 bolts) to Z\v0 (57 mm) bolt spacing (holes at Z\v0 [57 mm] bolt spacing are tapped for C\,0 1 bolts) ZB\zn () PA-71 PA-71 PA-7193 S-87-1 Galvanized stamped steelfor use in adapting Z\v0 (57 mm) insulator-bolt spacing (for C\,0 1 bolts) to 30 (7 mm) bolt spacing (for Z\x0 13 bolts) ZB\zn () PA-7191 PA-719 S-87- Galvanized stamped steelfor use in adapting 0 (51 mm) insulator-bolt spacing (for C\,0 1 bolts) to 30 (7 mm) bolt spacing (for Z\x0 13 bolts) ZB\zn () PA-7181 PA-7183 S-87-3 Galvanized stamped steelfor use in adapting 1C\,0 (35 mm) insulator-bolt spacing (for C\,0 1 bolts) to 30 (7 mm) bolt spacing (for Z\x0 13 bolts) ZB\zn () PA-7181 PA-7183 S-87- Cast aluminum alloyfor use in adapting 1C\,0 (35 mm) insulator-bolt spacing and 0 (51 mm) insulator-bolt spacing (for C\,0 1 bolts) to 30 (7 mm) bolt spacing (holes at 30 [7 mm] bolt spacing are tapped for Z\x0 13 bolts) PA-7181 PA-7183 S-801 S&C Specification Bulletin

8 Outdoor Station Post Insulators Dimensions in inches 3 (7) 3 (7) C\, (111) 3 (7) 3 (7) CATALOG NUMBERS PA-75R1, PA-753R1, AND PA-75R1 Nom. Ratings 1 Min. Sec. Wet Arcing Mechanical Strength Rating, Pounds 1 Tensile Compression T.R. (for corresponding porcelain station post insulator) Dimensions in H D 1 Net Weight, Lbs. (Kg.) M\, (9) (5) PA-75R1 05 (5) 5 (17) (.5) Z\v (7) 37C\, (99) 1 (35) 18 (57) PA-753R1 PA-75R (35) 18 (57) 5Z\v (133) 15 (.8) 1 (9.5) C\, (157) (559) PA (559) Z\x (15) 3 (1.) 1 To attain their rated cantilever strengths, Cypoxy Insulators must be base of the insulator. These insulators have tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter (marked Base ) must be oriented toward the mounting surface. 8 S&C Specification Bulletin

9 Indoor-Outdoor Insulators Dimensions in inches Z\v (57) 3 (7) 3 (7) C\, (111) 1B\, (1) Z\v (57) 5Z\v (133) 3 (7) 3 (7) Ratings Mechanical Strength Rating, Pounds Dimensions in Nom. 1 Min. Sec. Wet Arcing 1 Tensile Compression H R S Thread Size Net Weight, Lbs. (Kg.) Z\, (359) Z\, (13) Z\v (7) (171) (5) 1 (35) PA-7191d PA-719d PA-753R1df (171) (5) 1 (35) Z\v () Z\v () B\, (1) B\, (1) C\,0 1 h C\,0 1 h Z\x0 13 h Z\x (.0) 7 (3.) 15 (.8) Specialty l 5 15 (70) Z\v (57) PA-7188 (70) Z\x (0.5) 1 To attain their rated cantilever strengths, Cypoxy Insulators must be base of the insulator. l This insulator serves as a blade spacer in S&C Regulator Bypass Switches XL. When used alone its nominal rating is 00 volts. d This insulator has tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter (marked Base ) must be oriented toward the mounting surface. f For indoor use only, when applied at 3.5 kv. h Tapped oversize for galvanized steel hardware. S&C Specification Bulletin

10 Indoor Insulators Dimensions in inches 3 (7) 1C\, (35) 3 (7) 1C\, (35) Ratings Mechanical Strength Rating, Pounds Dimensions in Nom. 1 Min. Sec. Wet Arcing 1 Tensile Compression H D 1 D R S Thread Size Net Wt, Lbs. (Kg.) Bus M\, (1) 1Z\, (308) PA-71d PA-713d 3 (7) 3Z\v (83) Z\x () (70) Z\v () C\, () Z\x0 13 f Z\x0 13 f 1Z\x (0.7) Z\x (1.1) (197) 13 (330) 1Z\v 1 (70) Z\, () 5 (17) Z\v (159) (5) PA-71 PA-71d PA-7181 PA-7183 PA (17) Z\v (159) (5) C\, (111) C\, (111) 3 (95) Z\, (3) Z\, (3) Z\v () Z\v () Z\v () B\, (1) B\, (1) B\, (1) Z\x0 13 f Z\x0 13 f C\,0 1 f C\,0 1 f C\,0 1 Z\v (1.9) 5 (.) (1.8) M\, (.) Z\x (.9) 1 To attain their rated cantilever strengths, Cypoxy Insulators must be base of the insulator. d This insulator has tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter (marked Base ) must be oriented toward the mounting surface. f Tapped oversize for galvanized steel hardware. S&C Specification Bulletin

11 Indoor InsulatorsContinued Dimensions in inches D D H H D 1 D 1 CATALOG NUMBERS PA-780, PA-790, PA-790, PA-73, PA-73, AND AND PA-730 PA-730 CATALOG NUMBERS PA-781, PA-791, PA-7311, AND AND PA Nom. Ratings 1 Min. Sec. Wet Arcing Mechanical Strength Rating, Pounds 1 Tensile Compression Dimensions in D 1 D H R S Thread Size Net Wt, Lbs. (Kg.) Z\v 1 (70) Z\x (57) (1) PA-73 PA-7311 PA-780 PA-781 PA-790 PA-791 PA-730 PA-731 3B\, (9) 3M\, (98) 3C\, (8) 3 (95) (1) Center insert: Z\v () 0 bolt spacing inserts; Z\v () Center insert: M\, () 0 bolt spacing inserts; B\, (1 ) Center insert: B\,0 (11 ) 0 bolt spacing inserts; C\,0 (1 ) Z\, (1.0) (1.) M\, (.) 5Z\, (.3) 1 To attain their rated cantilever strengths, Cypoxy Insulators must be base of the insulator. This insulator has tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter (marked Base ) must be oriented toward the mounting surface. S&C Specification Bulletin

12 Indoor InsulatorsContinued Dimensions in inches CATALOG NUMBERS PA-78, PA-79, PA-731, AND PA-73 CATALOG NUMBERS PA-783, PA-793, PA-7313, AND PA-733 Nom. Ratings 1 Min. Sec. Wet Arcing Mechanical Strength Rating, Pounds 1 Tensile Compression Dimensions in D 1 D H Thread Size Net Wt, Lbs. (Kg.) Printed in U.S.A PA-731 PA B\, (9) 3C\, (8) Z\, (1.0) Z\v 1 (70) Z\x (57) (1) PA-78 PA-783 PA-79 PA-793 PA-73 PA-733 3M\, (98) 3 (95) (1) C\,0 (1 ) (1.) M\, (.) 5Z\, (.3) 1 To attain their rated cantilever strengths, Cypoxy Insulators must be base of the insulator. This insulator has tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter (marked Base ) must be oriented toward the mounting surface. 1 S&C Specification Bulletin

Procedure for Testing Direct Tension Indicators (DTI) Assemblies

Procedure for Testing Direct Tension Indicators (DTI) Assemblies Procedure for Testing Direct Tension Indicators (DTI) Assemblies 1. Scope: This test is to ensure that the bolt will be at or above the specified minimum bolt tension after installation when the direct

More information

Specifications. S&C BankGuard Plus Controls. For Substation Capacitor Banks and Shunt Reactors. Conditions of Sale

Specifications. S&C BankGuard Plus Controls. For Substation Capacitor Banks and Shunt Reactors. Conditions of Sale For Substation Capacitor Banks and Shunt Reactors Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified by the SPE CIAL

More information

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features UNILETS for use with Threaded Rigid Conduit and IMC. All Device Boxes have Construction. Furnished with Internal Ground Screw. Applications Accommodate wiring devices such as switches and receptacles.

More information

1/4 Turn Fastener - Black Painted Zinc 1/4 Turn Fastener - Stainless Steel 1/4 Turn Cam,.649 Offset - Zinc

1/4 Turn Fastener - Black Painted Zinc 1/4 Turn Fastener - Stainless Steel 1/4 Turn Cam,.649 Offset - Zinc ACCESSORIES Y001721 Y001722 Y001723 Y001724 Y001725 Y001726 Y001160 Y001363 Y001442 Y001184 Y002192 Y002193 PART NUMBER Y001721 Y001722 Y001723 Y001724 Y001725 Y001726 Y001160 Y001363 Y001442 Y001184 Y002192

More information

Seamers, Folding Tools & Brake

Seamers, Folding Tools & Brake Hand Seamers with Die-Cast Zinc Jaws S5 Compact 5 (127 mm) Jaws with Big 2 (51 mm) Bending Depth Hand Seamers with Forged Steel Jaws Seamers, Folding Tools Not for use with steel S9 Big 9 (229 mm) Jaws

More information

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable: Reclosers NOVA Three-Phase Recloser Functional Specification Guide Functional specification for NOVA three-phase recloser 1. Scope This specification describes the features and ratings of the NOVA recloser.

More information

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEB STANDARD 022 : 1994 Specification for 36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEYLON ELECTRICITY BOARD SRI LANKA Specification for 36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEB Standard 022 : 1994

More information

Best MATERIALS.com Discount Warehouse

Best MATERIALS.com Discount Warehouse Best MATERIALS.com Discount Warehouse Metal Bending Tools, Scribes & Awls 35 malco tool book better ideas for the real world. Hand Seamers Die-Cast Zinc Jaws Not for use with steel Die-Cast Zinc Jaws Not

More information

Flange Dimensions Class 125 Bronze Flange Dimensions Class 300 Bronze Flange Dimensions Class 150 Bronze Flange Dimensions

Flange Dimensions Class 125 Bronze Flange Dimensions Class 300 Bronze Flange Dimensions Class 150 Bronze Flange Dimensions Dimensions Class Bronze Dimensions Meets Ib. A.S.M.E. Stard Class 00 Bronze Dimensions Meets ANSI STD B. Nominal Dim. A O.D. Dim. B Circle Dim. C Hole No. Holes Nominal Dim. A Diam. Dim. B Min. Dim. C

More information

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A Group F : No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS Table : A No. Description 1. Make & Manufacturer 2. Place of Manufacturer 3. Voltage Ratio 4. Rating

More information

INTERMEDIATE METAL CONDUIT

INTERMEDIATE METAL CONDUIT PRODUCT GUIDE 08 CONDUIT PIPES CONDUIT FITTINGS FITTINGS FOR FLEXIBLE CONDUITS METALLIC ELECTRICAL BOXES AND COVERS CONDUIT BODIES WEATHERPROOF BOXES AND COVERS CHANNELS & SUPPORTS METAL ENCLOSURES CHANNELS

More information

Metal Bending Tools, Scribes & Awls

Metal Bending Tools, Scribes & Awls Metal Bending Tools, Scribes & Awls Hand Seamers Die-Cast Zinc Jaws Not for use with steel Die-Cast Zinc Jaws Not for use with steel malco tool book better ideas for the real world. S5R Compact 5 in. (127

More information

Type XTSR71 Sizes

Type XTSR71 Sizes (Page 1 of 13) s 494-5258 Type XTSR71 s 494-5258 Figure 1 Thomas XTSR71 Coupling 1. General Information 1.1 Thomas Couplings are designed to provide a mechanical connection between the rotating shafts

More information

Instructions for Installation. S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection TABLE OF CONTENTS INTRODUCTION INSTALLATION

Instructions for Installation. S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection TABLE OF CONTENTS INTRODUCTION INSTALLATION S&C Alduti-Rupter Switches Outdoor Distribution Three-Pole Double-Break Style and Three-Pole Double-Break Integer Style Live Parts Replacement on Switches with Catalog Number Supplement -R10 34.5 kv and

More information

Letter of Transmittal/Submittal

Letter of Transmittal/Submittal Letter of Transmittal/Submittal FROM: TO: Baker Concrete Construction 1904 Jasper Street DATE JOB NUMBER 09/23/10 Aurora, CO 80011 9921 303.367.8111 ATTENTION Nick Dewald 937.536.9000 RE: Bruce Herman

More information

Specifications. S&C Circuit-Switcher Mark V Outdoor Transmission (34.5 kv through 345 kv) Conditions of Sale SPECIAL TO THIS PRODUCT:

Specifications. S&C Circuit-Switcher Mark V Outdoor Transmission (34.5 kv through 345 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: S&C Circuit-Switcher Mark V Outdoor Transmission (34.5 kv through 345 kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as

More information

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End; 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 1100 1G Mall Box Appleton/Oz Gedney Catalog Number 1100 Manufacturer Appleton/Oz Gedney Description Cast Device Box, Height

More information

Contents. Grade 2, 5, 8 Hex Bolts 4. Heavy Hex Head Structural Bolts 6. A325 and A490 Tension Control Bolts (TC) 13. Nuts 22.

Contents. Grade 2, 5, 8 Hex Bolts 4. Heavy Hex Head Structural Bolts 6. A325 and A490 Tension Control Bolts (TC) 13. Nuts 22. Who we are Amcan Jumax is the result of a merging between Boulons Jumax and Amcan Threaded Products, two successful companies well established, both with excellent reputations. The new entity is a bigger

More information

C L. Farwest Corrosion Control Company Corrosion Control Products Company

C L.     Farwest Corrosion Control Company Corrosion Control Products Company Figure 1 OVP2 Outline Drawing Slots for 5/16" or M8 Bolt 3.22" (81.8mm) 3.05" (77.5mm) 3.5" (88.9mm) 1.0" x 1/8" Stainless Bracket (25.4mm x 3.2mm) 6.75" (171.5mm) 2.1" (53.3mm) Negative Bus (-) C L 2.12"

More information

COMMERCIAL ITEM DESCRIPTION SPLICE CONNECTORS

COMMERCIAL ITEM DESCRIPTION SPLICE CONNECTORS INCH-POUND A-A-59213A 28 May 2009 SUPERSEDING A-A-59213 18 May 1998 COMMERCIAL ITEM DESCRIPTION SPLICE CONNECTORS The General Services Administration has authorized the use of this commercial item description

More information

PIPE/CONDUIT SUPPORTS

PIPE/CONDUIT SUPPORTS PIPE/CONDUIT SUPPORTS Pipe/Conduit Clamps...102-105 Unicushion... 106 Pipe & Tubing (Cush-A-Clamp ) Clamps...107-110 Pipe Hangers... 111 Pipe Rollers...111-112 Pipe Brackets... 113 Reference Tables...114-120

More information

FRONT 2,5-H/SA 5. Extract from the online catalog. Order No.:

FRONT 2,5-H/SA 5. Extract from the online catalog. Order No.: Extract from the online catalog FRONT 2,5-H/SA 5 Order No.: 1700008 PC terminal block, Nominal current: 24 A, Nom. voltage: 250 V, Pitch: 5 mm, Number of positions: 1, Type of connection: Screw connection,

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3042 Reissued 09/2018 This report is subject to renewal 09/2019. DIVISION: 06 00

More information

General Information...SA1-SA4

General Information...SA1-SA4 SECTION S INDEX Product Description Page Number General Information................................................................SA1-SA4 Type FSK Thruwall & Floor Seal For Conduit, Pipe or Tubing............................

More information

Oversize and Twinsert Inserts

Oversize and Twinsert Inserts Oversize and Twinsert Inserts Technical Bulletin 943 www.emhart.com For Correcting Tapping Errors and Restoring Screw Thread Insert Tapped Holes. Oversize Inserts and Twinserts Two types of Heli-Coil Thread

More information

POWER-Skru Large Diameter Concrete Screw

POWER-Skru Large Diameter Concrete Screw POWER-Skru Large Diameter Concrete Screw Description The POWER-Skru Large Diameter Concrete Screw is a highstrength screw anchor with self-tapping threads that offer a unique undercutting design for anchoring

More information

User s Manual For CT Model IMB

User s Manual For CT Model IMB User s Manual For CT Model IMB 2 of (13) Contents: A. Introduction... 3 B. Steps on receipt and opening the cases... 3 C. Transportation and handling... 3 D. Unpacking the transformer... 4 E. Storage...

More information

Hex Cap Screws Coarse & Fine Thread

Hex Cap Screws Coarse & Fine Thread INDUSTRIAL Product Description Hex head cap screws are manufactured to dimensional standards of ASME B18.2.1 and to various material and mechanical standards of ASTM and SAE. The length of a cap screw

More information

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples... SECTION E INDEX Product Description Page Number Conduit End Bells.......................................EA Hex Reducing Bushings..................................EA2 Conduit Hubs......................................EA-EA4

More information

Installation Instructions

Installation Instructions Column & Beam Units with Debris Netting Installation Instructions Laminated Wood Systems, Inc. Seward, Nebraska 800-949-3526 2015 LWS, INC. AVR-NET INSTALL 05-12-16 AVR Installation Notes 1 Safety The

More information

ESR-3042* Reissued August 1, 2012 This report is subject to renewal September 1, 2014.

ESR-3042* Reissued August 1, 2012 This report is subject to renewal September 1, 2014. ICC-ES Evaluation Report www.icc-es.org (800) -687 (6) 699-0 ESR-0* Reissued August, 0 This report is subject to renewal September, 0. A Subsidiary of the International Code Council DIVISION: 06 00 00

More information

Thomas Disc Couplings Installation and Maintenance Series 71 Sizes (Page 1 of 11) DANGER!

Thomas Disc Couplings Installation and Maintenance Series 71 Sizes (Page 1 of 11) DANGER! Thomas Disc s Installation and Maintenance Series 71 s 150-1038 (Page 1 of 11) This is the Original Document in English Language Figure 1 - Thomas Series 71 1. General Information 1.1. Thomas Series 71

More information

FSK1VDRA 1G Al DPLX RCPT CVR

FSK1VDRA 1G Al DPLX RCPT CVR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FSK1VDRA 1G Al DPLX RCPT CVR Appleton/Oz Gedney Catalog Number Manufacturer Weight per unit Product Category FSK1VDRA

More information

Thru Wall Floor Seals For New Installation

Thru Wall Floor Seals For New Installation The O-Z/Gedney Thruwall and Floor Seals provide a positive means of sealing pipe, conduit or tube where they pass through a concrete foundation of a structure below grade or below ground water level or

More information

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

5/16 Flange nut. Bolt Keeper Plate (8 Sq. SYS.) (3) 1/2 x 3 Hex head connector zinc plated bolt w/ washers and nut. Anchor 3 sq. 7 Ga. 2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc

More information

Thread Repair & Thread Protection

Thread Repair & Thread Protection Thread Repair & Thread Protection Screw Thread Inserts, Kits & Components for Industrial Maintenance, Repair and Overhaul Bulletin 998 C E R T I F I E D ISO 9001 AS 9100 TS 16949 ISO 14001 The HELI-COIL

More information

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013) S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013) 1.0 GENERAL 1.1 This specification covers the electrical and mechanical

More information

MISCELLANEOUS SIGN CONNECTION DETAILS TYPICAL ROUTE MARKER ASSEMBLIES SIGN TO POST MICHIGAN DEPARTMENT OF TRANSPORTATION

MISCELLANEOUS SIGN CONNECTION DETAILS TYPICAL ROUTE MARKER ASSEMBLIES SIGN TO POST MICHIGAN DEPARTMENT OF TRANSPORTATION 5-4" SEE DETAIL I COUPLING BAR ON 3 2-10" CANTILEVER SIGN SUPPORT TYPICAL ROUTE MARKER ASSEMBLIES 5/1 DIAMETER STAINLESS STEEL BOLT AND NYLON INSERT LOCK NUT SELF-ALIGNING STEEL REINFORCING PLATE ( TYPE

More information

The edge you ve been waiting for

The edge you ve been waiting for R I G H T A N G L E C L I N C H F A S T E N E R S The edge you ve been waiting for Revised 606 PEM R ANGLE RIGHT ANGLE CLINCH FASTENER TYPES RAA AND RAS Self-clinching PEM R ANGLE fasteners provide you

More information

2.1. Product Description

2.1. Product Description .1 NEMA TP-1 Energy-Efficient Type DT-3 Contents Description NEMA TP-1 Energy-Efficient Features, Benefits and Functions........... Standards and Certifications............... Catalog Selection................

More information

ULT R A SPAC E SAV E R

ULT R A SPAC E SAV E R ULT R A SPAC E SAV E R Double Capacity, Modular Construction The Ultra Space Saver provides easy and ample space for u-lock security on nearly any bike, including bikes with fenders. Thanks to design enhancements,

More information

Kerkau Manufacturing. B16.5 Flange Book

Kerkau Manufacturing. B16.5 Flange Book Kerkau Manufacturing B16.5 Flange Book TABLE OF CONTENTS Revision 1 Title Page Table of Contents Tolerance Page Permissible Imperfections Dimensions of Flange Facings (all pressure rating classes) Dimensions

More information

HEADLINE BUILDING MATERIALS

HEADLINE BUILDING MATERIALS EADLINE BUILDING MATERIALS eb: www.hbm.ae l Email: commercial@hbm.ae eavy ex Structural Bolts ASTM A 325M Metric Series Dimensions P.O. Box 37366, Dubai, UAE l Tel: +971 4 3475675 l Fax: +971 4 347 5485

More information

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785)

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785) 141 E 1450 Rd. Lawrence, KS 66044 (75) 594-5696 Perma-Column Installation Instructions i Unlike any other concrete post-frame foundation system, Perma-Column Precast Concrete Piers use 10,000 psi concrete

More information

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval Redwood City Electric, Inc. TRANSMITTAL LETTER To: Transworld Construction, Inc. 1178 Folsom Street San Francisco, CA 94103 Date: 05/31/12 Job #: 9340 Regarding: SFO DATA CENTER Attn: Rob Acero We are

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Low Profile Tilt Mount Model: U.S. Toll Free: 1-866-752-6271 Outside N. America: 1-503-748-5799 E-mail: ts@planar.com FRANCE Phone: +33 5 6378 3810 E-mail: emeats@planar.com

More information

Engineering Data Stock Ejectors

Engineering Data Stock Ejectors Engineering Data s The New Industry Standard This product may be covered by one or more patents or patent applications. See http://www.standardlifters.com/patents.html for details. 8/14 - Rev. 1 Things

More information

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers .5 Transformers Distribution Transformers Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Totally Enclosed Non-Ventilated Transformers Product Description Note: The following pages provide listings

More information

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications Blank Bodies for Brazed Hubs UNILETS for Use with Threaded Rigid Metal Conduit and IMC. Available with Hub Sizes from 1/2 through 1-1/2 (Union 1/2 through 1-1/4 ). Furnished with Internal Ground Screw.

More information

Evaluation of In-Pavement Light Fixture Designs and Performance

Evaluation of In-Pavement Light Fixture Designs and Performance Evaluation of In-Pavement Light Fixture Designs and Performance Presented to: IES ALC Fall Technology Meeting By: Joseph Breen Date: Background In-Pavement Light Fixture Assemblies Utilize a Circle of

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Low Profile Flat Mount Model: U.S. Toll Free: 1-866-752-6271 Outside N. America: 1-503-748-5799 E-mail: ts@planar.com FRANCE Phone: +33 5 6378 3810 E-mail: emeats@planar.com

More information

SMKDSP 1,5/ 8. Extract from the online catalog. Order No.:

SMKDSP 1,5/ 8. Extract from the online catalog. Order No.: Extract from the online catalog SMKDSP 1,5/ 8 Order No.: 1733473 The figure shows a 10-position version of the product PC terminal block, Nominal current: 17.5 A, Nom. voltage: 250 V, Pitch: 5 mm, Number

More information

PRODUCT INFORMATION. ASTM B633,SC1, Type III (Fe/Zn 5) Rod/Anchor Diameter

PRODUCT INFORMATION. ASTM B633,SC1, Type III (Fe/Zn 5) Rod/Anchor Diameter PRODUCT INFORMATION Internally Threaded Expansion Anchor PRODUCT DESCRIPTION The is an all-steel, machine bolt anchor available in carbon steel. It can be used in solid concrete, hard stone, and solid

More information

Model BiConiLog Antenna. User Manual

Model BiConiLog Antenna. User Manual Model 3149 BiConiLog Antenna User Manual ETS-Lindgren Inc. reserves the right to make changes to any products herein to improve functioning or design. Although the information in this document has been

More information

Max. Rec. Load. Wt. Per Inch lbs. kn lbs. kn lbs. kg. Wt. Per Inch lbs. kn lbs. kn lbs. kg 750 F (399 C)

Max. Rec. Load. Wt. Per Inch lbs. kn lbs. kn lbs. kg. Wt. Per Inch lbs. kn lbs. kn lbs. kg 750 F (399 C) FIG. 10 FIG. 15 & 15L Function: Designed for use in pipe hanger assemblies. (Type 304 or 316 Stainless Steel upon request) Ordering: Specify figure number, rod size, length (), material, and finish. 650

More information

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC STANDARD SPECIFICATION SECTION 05121 MISCELLANEOUS METALWORK PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, fabrication, and installation of structural steel, connecting bolts, pipes,

More information

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS 006: 2008 CEB SPECIFICATION COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS CEYLON ELECTRICITY BOARD SRI LANKA Specification for COMBINED METERING TRANSFORMERS (OUTDOOR TYPE) FOR

More information

Bridgeport Magnetics Design Guide

Bridgeport Magnetics Design Guide Bridgeport Magnetics Design Guide Our design guide takes you step by step through the process of designing a toroidal transformer. No engineering design charges for all standard designs. State of the art

More information

SECTION 3. BOLTS. bolt is a standard AN-type or a special-purpose bolt, and sometimes include the manufacturer.

SECTION 3. BOLTS. bolt is a standard AN-type or a special-purpose bolt, and sometimes include the manufacturer. 9/8/98 AC 43.13-1B SECTION 3. BOLTS 7-34. GENERAL. Hardware is the term used to describe the various types of fasteners and small items used to assemble and repair aircraft structures and components. Only

More information

Ground Clamps Cable Tray

Ground Clamps Cable Tray commercial and industrial fittings: ing Fittings and Solderless Connectors Clamps Cable Tray Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both tray and

More information

SLKK 5. Extract from the online catalog. Order No.:

SLKK 5. Extract from the online catalog. Order No.: Extract from the online catalog SLKK 5 Order No.: 0461018 Double-level terminal block with protective conductor foot, cross section: 0.2-4 mm², width: 6.2 mm, color: Gray Commercial data EAN 4017918002381

More information

SECTION CONCRETE ANCHORING. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION CONCRETE ANCHORING. Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 03 15 00 CONCRETE ANCHORING Display hidden notes to specifier. (Don't know how? Click Here) A. General purpose mechanical anchors for horizontal and vertical

More information

Fasteners. Fastener. Chapter 18

Fasteners. Fastener. Chapter 18 Fasteners Chapter 18 Material taken from Mott, 2003, Machine Elements in Mechanical Design Fastener A fastener is any device used to connect or join two or more components. The most common are threaded

More information

Mudsill Anchorage Systems in Cripple Wall Retrofits

Mudsill Anchorage Systems in Cripple Wall Retrofits Mudsill Anchorage Systems in Cripple Wall Retrofits By Howard Cook, Contractor Bay Area Retrofit Inc. Wendy Allen P.E Anchorage Systems Field Engineer Simpson StrongTie December 21, 2005 International

More information

Downtown Rack. Custom logo option available

Downtown Rack. Custom logo option available Custom logo option available Downtown Rack The Downtown Rack uses thick, square-tube construction that can t be cut with a pipe cutter. The extended width of the Downtown Rack makes for easy bike parking

More information

ULTRA SPACE SAVER Installation Instructions

ULTRA SPACE SAVER Installation Instructions Installation Instructions The Ultra Space Saver has several steps for installation. Note that the single and double sided setups and parts are different. Make sure you follow the instructions according

More information

Model Biconical Antenna. User Manual

Model Biconical Antenna. User Manual Model 3109 Biconical Antenna User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained

More information

Sockets. Dimensions; Mechanical & Performance Requirements. Socket Head Cap Screws Body & Grip Lengths - Socket Cap Screws...

Sockets. Dimensions; Mechanical & Performance Requirements. Socket Head Cap Screws Body & Grip Lengths - Socket Cap Screws... imensions; Mechanical & Performance Requirements Socket Head Cap Screws... 2-4 Body & Grip Lengths - Socket Cap Screws... 5-6 Low Head Socket Cap Screws... 7 Button Head Socket Cap Screws... 8 Flat Head

More information

Thomas Disc Couplings Installation and Maintenance Series 71-8 Sizes (Page 1 of 10) DANGER!

Thomas Disc Couplings Installation and Maintenance Series 71-8 Sizes (Page 1 of 10) DANGER! Thomas Disc s Installation and Maintenance Series 71-8 s 225-750 (Page 1 of 10) This is the Original Document in English Language Figure 1-1. General Information Thomas Series 71-8 1.1. Thomas Series 71-8

More information

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS PURCHASE SPECIFICATIONS OF 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS SPECIFICATION NO. : OR12423 REVISION NO. : Rev 00 DATE : 01.03.2011 DISTRIBUTION : PI - 4 copies O/C - 1 copy PREPARED BY

More information

Field Assembly and Installation

Field Assembly and Installation S&C Circuit-Switchers Mark V a and Mark IV Outdoor Transmission Pre-insertion Inductors for Already-Installed Circuit-Switchers Field Assembly and Installation Table of Contents Section Page Section Page

More information

Planar FWMG-MXL INSTALLATION INSTRUCTIONS

Planar FWMG-MXL INSTALLATION INSTRUCTIONS Planar FWMG-MXL INSTALLATION INSTRUCTIONS Fixed Wall Mount for Ultra Large Displays 50-98 weighing less than 300 lbs. Part Number: 955-0217-00 Planar, A Leyard 1195 NW Compton Drive Beaverton, OR 97006

More information

Swerve Rack CUSTOM RACKS AVAILABLE

Swerve Rack CUSTOM RACKS AVAILABLE CUSTOM RACKS AVAILABLE Swerve Rack The design of the Swerve mirrors the bike frame, thus providing superior bike support while making it easy to secure both the bike frame and wheel with a standard u-lock.

More information

Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation

Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation Instruction Manual 1052 Size 20 Actuator (H) Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications...

More information

Post & Rail. Includes: Crossbuck, 2-Rail, 3-Rail and 4-Rail POST SUPPORT OPTIONS

Post & Rail. Includes: Crossbuck, 2-Rail, 3-Rail and 4-Rail POST SUPPORT OPTIONS Post & Rail Includes: Crossbuck, 2-Rail, 3-Rail and 4-Rail STAGGER RAIL ENDS FOR GREATER STRENGTH ALLOW 1-1/2" GAP ON HINGE SIDE OF GATE AND 1-1/4" ON LATCH SIDE OF GATE HARDWARE DIG HOLES 30" MINIMUM

More information

METRIC FASTENERS 1520 METRIC FASTENERS

METRIC FASTENERS 1520 METRIC FASTENERS 1520 METRIC FASTENERS METRIC FASTENERS A number of American National Standards covering metric bolts, screws, nuts, and washers have been established in cooperation with the Department of Defense in such

More information

Flush Mount. SunEarth Flush Mount Installation Manual. SunEarth Flush Mount. Asphalt Shingle Roofing

Flush Mount. SunEarth Flush Mount Installation Manual. SunEarth Flush Mount. Asphalt Shingle Roofing Flush Mount SunEarth Flush Mount Installation Manual Thank you for choosing the SunEarth flush mount method. It provides a strong durable solution for mounting SunEarth collectors parallel to the roof

More information

Section 2 Outdoor Voltage Transformers

Section 2 Outdoor Voltage Transformers Section 2 Outdoor Voltage Transformers GE Meter 130 Main St., Somersworth, NH 03878 USA & Canada: (800) 626-2004 Fax: (518) 869-2828; GE Worldwide: (518) 869-5555 2-1 120 V to 600 V BIL 10 kv Outdoor Voltage

More information

Model Biconical Antenna. User Manual

Model Biconical Antenna. User Manual Model 3109 Biconical Antenna User Manual ETS-Lindgren Inc. reserves the right to make changes to any products herein to improve functioning or design. Although the information in this document has been

More information

Setting Standards For Excellence

Setting Standards For Excellence To: Holders of ANSI C29.7-I 996 From: NEMA Communications Department Date: October 7,2002 Subject: Reaffirmation of ANSI C29.7-1996 Setting Standards For Excellence The ANSI Board of Standards Review has

More information

RATCHET CABLE CUTTER

RATCHET CABLE CUTTER OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL 764 RATCHET CABLE CUTTER Read and understand this material before operating or servicing this equipment. Failure to understand how to safely operate this

More information

Pole Line Hardware. Heavy duty spool rack SS401E 1 9 1/ SS802E / SS803E /

Pole Line Hardware. Heavy duty spool rack SS401E 1 9 1/ SS802E / SS803E / Heavy duty spool rack CATALOGUE NUMBER OVERALL WEIGHT (100 pcs) STD NO. WIRES LENGTH (in.) lb kg PKG SS401E 1 9 1/2 300 136.3 10 SS802E 2 17 1/2 520 236.3 5 SS803E 3 25 1/2 780 354.5 5 SS804E 4 33 1/2

More information

Ledex Tubular Linear Solenoids

Ledex Tubular Linear Solenoids Ledex Tubular Linear Solenoids Force lbs. (newtons) 10 (.) (35.5) 6 (6.69) (17.79) 10% Duty Cycle 70W 5% Duty Cycle W 50% Duty Cycle 1W 100% Duty Cycle 7W saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex

More information

ESR-1799 Reissued April 2014 This report is subject to renewal June 1, 2015.

ESR-1799 Reissued April 2014 This report is subject to renewal June 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 42-6587 (562) 699-054 ESR-799 Reissued April 204 This report is subject to renewal June, 205. A Subsidiary of the International Code Council DIVISION: 0 00

More information

Modular Gazebo Kit Series GardenHouse 12

Modular Gazebo Kit Series GardenHouse 12 Octagonal CUPOLA screened with louvers and light fixture Modular Gazebo Kit Series GardenHouse 12 with DOUBLE-TIERED Roof Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or

More information

OWNER: POSITION AUTHOR: POSITION Dan Boettcher Director of Engineering Richard Richardson Vice-Dir of Engineering

OWNER: POSITION AUTHOR: POSITION Dan Boettcher Director of Engineering Richard Richardson Vice-Dir of Engineering KRESS CORPORATION ENGINEERING Design of Thru and Threaded Holes Standard DOC ID 095007 REVISION A TYPE PORTAL OWNER: POSITION AUTHOR: POSITION Dan Boettcher Director of Engineering Richard Richardson Vice-Dir

More information

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility B 64" 1626 602'-8 1/16" 183695 548'-0" 167030 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 373839 40 25 IMPACT 1500A 48" 12 27'-5" 8355 [] 3x7 CL A Galvanized

More information

Hollo Set Drop-In Anchors

Hollo Set Drop-In Anchors Description The Hollo Set drop-in anchor is an internally threaded, flush mount expansion anchor designed for use in hollow and solid base materials. In hollow concrete block and precast hollow core plank,

More information

SL Let it Rain. Solutions for fast, precise cuts in thin walled K-Style & half round gutter.

SL Let it Rain. Solutions for fast, precise cuts in thin walled K-Style & half round gutter. SL15114 Let it Rain Solutions for fast, precise cuts in thin walled K-Style & half round gutter. Quick-Action Gutter Outlet Saws & Combination Arbor & High Speed Pilot Drill For downspout that always fits

More information

NSTRUCTIONS For Field Assembly and Installation

NSTRUCTIONS For Field Assembly and Installation s&c Series 2000 Circuit-Switchers 161kv and 230kv NSTRUCTONS For Field Assembly and nstallation TABLE OF CONTENTS Section NTRODUCTON NSTALLATON...... Page Number Section Page Number....1 NSPECTON SCHEDULE

More information

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads. -156 Purpose & Industrial Control Purpose (1000 kva and Below) mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. shall be manufactured

More information

Transmission Line Support Systems

Transmission Line Support Systems Antenna Support Bracket for transmission line The Antenna Support Bracket angle mounts directly to a 4-1/2" (114 mm) OD antenna pipe mount or tower leg. This is ideal for supporting transmission line runs

More information

INSTALLATION MANUAL H A

INSTALLATION MANUAL H A INSTALLATION MANUAL CABINET RACK CR-43-6 (4-UNIT SIZE) Be sure to read this installation manual thoroughly before installing this Cabinet Rack. For the mounting procedures of the components and the relevant

More information

Flat Panel Stand FPZ-655. for 32" to 55" Flat Panel Screens FEATURES. Reinforced universal adapter plate for a strong hold

Flat Panel Stand FPZ-655. for 32 to 55 Flat Panel Screens FEATURES. Reinforced universal adapter plate for a strong hold FPZ-655 Flat Panel Stand for 32" to 55" Flat Panel Screens For a viewing experience that really stands out, Peerless FPZ-655 Universal Flat Panel Stand for 32" 55" flat panel TVs provides a brilliant combination

More information

SECTION - 3 EARTHING CLAMPS & FITTINGS

SECTION - 3 EARTHING CLAMPS & FITTINGS SECTION - 3 EARTHING CLAMPS & FITTINGS 78 EARTHING CONDUCTOR TO FLAT SURFACE TYPE ESS - SINGLE CONDUCTOR TYPE EST - TWIN CONDUCTOR Types ESS (single conductor) and EST (twin conductor) clamps are designed

More information

FIRE PROTECTION PRODUCTS

FIRE PROTECTION PRODUCTS FEATURES Rev. 7-11 Mueller Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also,

More information

MKDS 3/ 4. Extract from the online catalog. Order No.:

MKDS 3/ 4. Extract from the online catalog. Order No.: Extract from the online catalog MKDS 3/ 4 Order No.: 1711042 PC terminal block, Nominal current: 24 A, Nom. voltage: 400 V, Pitch: 5 mm, Number of positions: 4, Connection method: Screw connection, Mounting:

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS CREATING POSITIVE CUSTOMER EXPERIENCES INSTALLATION INSTRUCTIONS Universal Low Profile Tilt Mount for 42 to 63 Flat Panels NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada Phone:

More information

PFW 6851 Display Wall Mount, Turn & Tilt 80 kg INSTALLATION INSTRUCTIONS

PFW 6851 Display Wall Mount, Turn & Tilt 80 kg INSTALLATION INSTRUCTIONS Display Wall Mount, Turn & Tilt 80 kg INSTALLATION INSTRUCTIONS 9531-007-Z00-01 Table of Contents Warning Statements 2 Parts List 3 Installation Tools 3 Wood Stud Installation 5 Concrete Surface Installation

More information

POLE LINE HARDWARE POLE LINE HARDWARE. HI-LINE UTILITY SUPPLY CO. Phone: Fax:

POLE LINE HARDWARE POLE LINE HARDWARE. HI-LINE UTILITY SUPPLY CO. Phone: Fax: 146 MACHINE BOLTS w/ square nut Rolled threads; s six inches or longer have con-type points. Hot dip galvanized. 860412 3/8" 4.5" 3" 250 8706 6" 3" 100 8707 7" 3" 100 8708 1/2" 8" 4" 100 8710 10" 4" 50

More information