1 SCD, ASCD Square Cone Diffuser CM = CEILING MODULE CEILING OPENING D = DUCT SIZE OD = D - 1/8" (3mm) MIN. 1" (25mm) A Optional 4th Cone STANDARD CONSTRUCTION: SCD - Steel construction ASCD - Aluminum construction DAMPERS: VCR7 - Radial opposed blade steel damper (N/A with 4", 5", or 7" inlets) VCR8 - Full Flow duct mounted steel damper VCR8E - Full Flow diffuser mounted steel damper VCR9 - Radial diffuser mounted steel damper (N/A with 4", 5", 7", or 15" inlets) SB - SECTORIZING BAFFLE: Steel construction Way pattern Way pattern Way pattern (N/A if a damper is selected) FINISH: B12 White (Optional Finishes Available) Duct Size Ceiling Opening A 4" 5" 6" 7" 8" 10" 12" 14" 15" 12" x 12" 10 1/2" x 10 1/2" 1 1/8" 20" x 20" 18" x 18" 2 1/2" 24" x 24" 22" x 22" 2 1/2" 300mm x 300mm 249mm x 249mm 29mm 500mm x 500mm 449mm x 449mm 64mm 600mm x 600mm 549mm x 549mm 64mm indicates available inlet size OPTIONS: R6 - Insulated Backpan (style 31 or 4TS, N/A with 20"x20" or 500mm x 500mm) AFI - 1/2" fiberglass with foil/scrim vapor barrier insulated backpan (style 31, 20"x20" or 500mm x 500mm only) BN - Beaded Inlet Neck with extended depth (2 1/2" (64mm)). Not available on ASCD FC - Fixed core is available only for 24"x24" & 600mm x 600mm styles 17 & 31. For surface mount installation use of plaster frame is recommentded. RC - Removable core is available for all sizes and styles 4C - 4th cone (24"x24" and 600mm x 600mm units only) MRI - aluminun construction. Available for ASCD 24"x24" & 600mm x 600mm, styles 31 & 17 only. Not available with 4th cone, dampers, or sectorizing baffle options SHEET 1 OF 3 SCD / ASCD SQUARE CONE DIFFUSER REV. O SCD-1-1 ASCD-1-1

2 Lay-in & Surface Mount Frames: SCD, ASCD Square Cone Diffuser 31 - T-Bar Lay-In 31 - Surface Mount Overall = Face Size - 1/4" (6mm) Ceiling Opening Diffuser Face Size - 1/4" (6mm) 17 - Bolt Slot T-bar 17 - Tegular T-Bar 4TS Clip-On Recessed Spline (24"x24" only) 4 - Spline 1 1/8" 1/4" Spline on two opposite sides only 2 - Snap-In NOTES: For flat tee installation use style 31 with adaptor clips from ceiling supplier, or order 916 corner clip separately. 20" x 20" & 500mm x 500mm available in style 31 only ASCD available with style 31 and 17 only Dampers and sectorizing baffles ship loose Factory tolerance u 1/32" (1mm) SHEET 2 OF 3 SCD / ASCD SQUARE CONE DIFFUSER REV. O SCD-1-1 ASCD-1-1

3 Lay-in Panels: Available in SCD only SCD, ASCD Square Cone Diffuser 3P - T-Bar Lay-In 2P - Snap-In Panel Overall - 1/4" (6mm) 17P - Bolt Slot T-bar 4P - Spline 17P - Tegular T-Bar PANEL SIZE: 12" x 12" face size: 24" x 24" face size: 24" x 12" panel 30" x 30" panel 16" x 16" panel 48" x 24" panel 20" x 20" panel 24" x 24" panel 48" x 12" panel 300mm x 300mm face size: 600mm x 300mm panel 400mm x 400mm panel 500mm x 500mm panel 600mm x 600mm panel 1200mm x 300mm panel 600mm x 600mm face size: 750mm x 750mm panel 1200mm x 600mm panel SHEET 3 OF 3 SCD / ASCD SQUARE CONE DIFFUSER REV. O SCD-1-1 ASCD-1-1

4 SCDA, ASCDA Adjustable Square Cone Diffuser CM = CEILING MODULE OR OPENING D = DUCT SIZE OD = D - 1/8" (3mm) MIN. 1" (25mm) A (MAX) PATTERN CONTROLLER SECONDARY PATTERN CONTROLLER Optional 4th Cone STANDARD CONSTRUCTION: SCDA - Steel construction ASCDA - Aluminum construction DAMPERS: VCR7 - Radial opposed blade steel damper (N/A with 4", 5", or 7" inlets) VCR8 - Full Flow duct mounted steel damper VCR8E - Full Flow diffuser mounted steel damper VCR9 - Radial diffuser mounted steel damper (N/A with 4", 5", 7", or 15" inlets) SB - SECTORIZING BAFFLE: Steel construction Way pattern Way pattern Way pattern (N/A if a damper is selected) FINISH: B12 White (Optional Finishes Available) Duct Size A B 4" 5" 6" 7" 8" 10" 12" 14" 15" 12" x 12" 1 3/4" 13 7/16" 20" x 20" 2 7/8" 21 5/8" 24" x 24" 3 3/4" 25 7/16" 300mm x 300mm 44mm 341mm 500mm x 500mm 73mm 549mm 600mm x 600mm 95mm 646mm indicates available inlet size OPTIONS: BN - Beaded Inlet Neck with extended depth (2 1/2" (64mm)). Not available on ASCDA FC - Fixed core is available only for 24"x24" & 600mm x 600mm styles 3 & 17. For surface mount installation use of plaster frame is recommended. RC - Removable core is available for all sizes and styles 4C - 4th cone (24"x24" and 600mm x 600mm units only) MRI - aluminun construction. Available for ASCDA 24"x24" & 600mm x 600mm, styles 1 & 3 only. Not available with 4th cone, dampers, or sectorizing baffle options. NOTES: Factory tolerance u 1/32"(1mm) Dimension B varies with inlet size Secondary pattern controllers apply to certain inlet sizes only Dampers and sectorizing baffles ship loose SHEET 1 OF 3 SCDA / ASCDA ADJUSTABLE SQUARE CONE DIFFUSER REV. J SCDA-1-1 ASCDA-1-1

5 SCDA, ASCDA Adjustable Square Cone Diffuser Lay-In & Surface Mount Frames: 1 - Surface Mount 1/4" (6mm) Ceiling Opening 3 - T-Bar Lay-In For 24" x 24", 500mm x 500mm, & 600mm x 600mm: Overall = Face Size - 1/4" (6mm) 17 - Bolt Slot T-bar 1 1/4" (32mm) Face Overall = B For 12" x 12", 20" x 20", & 300mm x 300mm: Overall = Face Size - 1/4" (6mm) 17 - Tegular T-Bar 2 - Snap-In 4 - Spline Notes: ASCDA available with style 1 & 3 only 20" x 20" & 500mm x 500mm available in styles 1 & 3 only For flat tee installation use style 3 with adaptor clips from ceiling supplier, or order 916 clips separately SHEET 2 OF 3 SCDA / ASCDA ADJUSTABLE SQUARE CONE DIFFUSER REV. J SCDA-1-1 ASCDA-1-1

6 Lay-in Panels: Available in SCDA only SCDA, ASCDA Adjustable Square Cone Diffuser 3P - T-Bar Lay-In Panel Overall - 1/4" (6mm) 2P - Snap-In 17P - Bolt Slot T-bar 4P - Spline 17P - Tegular T-Bar PANEL SIZE: 12" x 12" face size: 24" x 24" face size: 24" x 12" panel 30" x 30" panel 16" x 16" panel 48" x 24" panel 20" x 20" panel 24" x 24" panel 48" x 12" panel 300mm x 300mm face size: 600mm x 300mm panel 400mm x 400mm panel 500mm x 500mm panel 600mm x 600mm panel 1200mm x 300mm panel 600mm x 600mm face size: 750mm x 750mm panel 1200mm x 600mm panel SHEET 3 OF 3 SCDA / ASCDA ADJUSTABLE SQUARE CONE DIFFUSER REV. J SCDA-1-1 ASCDA-1-1

7

AMDL - Aluminum Linear Louver Face Diffuser Submittal Sheet OVERALL DIFFUSER = NOM. + 5.750 (146) NECK OVERALL = NOM. -.125 (3) NOM. DCUT OVERALL DIFFUSER = NOM. + 5.750 (146) 2.094 (53) TYPE 1 SURFACE

More information

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW GENERL PROUCT OVERVIEW Ceiling iffusers Quality ssured Products, unobtrusive clean lines for appearance, careful engineering and professional workmanship with the backing of an industry leader - these

More information

GRILLE AND REGISTER OPTIONS AND ACCESSORIES

GRILLE AND REGISTER OPTIONS AND ACCESSORIES GRILLE ND REGISTER OPTIONS ND CCESSORIES PRODUCT OVERVIEW OPTIONS ND CCESSORIES FOR FSTENING ND MOUNTING FRMES Up to four methods of fastening available for most models. Sub-frame available for professionally

More information

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR C1 Table of Contents 1, 15 51, 515 feature a neck mounted rotatable core with either a round or square neck. Aluminum or steel perforated face is, 5 R, supply, ceiling diffusers feature neck mounted curved

More information

Manually adjustable blades Return air VAV cooling only VAV cooling and warm up heating TF-D TF-RA TB-C TB-CW

Manually adjustable blades Return air VAV cooling only VAV cooling and warm up heating TF-D TF-RA TB-C TB-CW FORM 10.3 REV 0407 THERM-FUSER THERMLLY POWERED VV DIFFUSER CEILING PPROCHES MODULR VV SYSTEMS Models: TF-C VV cooling only. TF-CW VV cooling and warm up heating TF-HC VV cooling and VV heating TF-D TF-R

More information

FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I NSTA LL AT IO N & OPER AT I ON M AN UA L

FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I NSTA LL AT IO N & OPER AT I ON M AN UA L I NSTA LL AT IO N & OPER AT I ON M AN UA L FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I OM F L-1 0/ FL- 15 /FL-20 /FL-25/FL-3 0 FlowBar Installed During Hard Ceiling

More information

DRYWALL CEILING SPLINE KICKER REFLECTOR DIFFUSER LENGTH TABLE DIFFUSER LENGTH TABLE DESCRIPTION 2' IND 3' IND 4' IND 6' IND 8' IND

DRYWALL CEILING SPLINE KICKER REFLECTOR DIFFUSER LENGTH TABLE DIFFUSER LENGTH TABLE DESCRIPTION 2' IND 3' IND 4' IND 6' IND 8' IND SUPPLEMENTAL INSTALLATION TYPE LG-WWD-44, R-WWD-44 & RP-WWD-44 510553-2000 WHICH IS CONTRARY TO THE CONTAINED HEREIN. P/C PG. 1 OF 1 1/4-20 THREADED ROD OR EQUAL SUPPLIED PANHEAD SHEET METAL SCREW HEX

More information

INSTALLATION & OPERATION MANUAL ML-37 / ML-38 / ML-39 MLR-37 / MLR-38 / MLR-39. Redefine your comfort zone.

INSTALLATION & OPERATION MANUAL ML-37 / ML-38 / ML-39 MLR-37 / MLR-38 / MLR-39. Redefine your comfort zone. INTALLATION & OPERATION MANUAL ML-37 / ML-38 / ML-39 MLR-37 / MLR-38 / MLR-39 IOM Linear lot Ceiling Diffusers Factory Cut upply ML-37 ML-38 ML-39 Factory Cut Return MLR-37 MLR-38 MLR-39 Factory pacer

More information

INSTALLATION INSTRUCTIONS FIXTURE SERIES: SAE 202 MOUNTING TYPE: RECESSED WALL / SLOT PAGE: 1 OF 8

INSTALLATION INSTRUCTIONS FIXTURE SERIES: SAE 202 MOUNTING TYPE: RECESSED WALL / SLOT PAGE: 1 OF 8 INSTALLATION INSTRUCTIONS FIXTURE SERIES: SAE 202 MOUNTING TYPE: RECESSED WALL / SLOT PAGE: 1 OF 8 90v INNER CORNER KIT "R" (REGRESSED) POSITION CROSS-SECTION VIEW "S" (SHIELDING AT TOP) POSITION CROSS-SECTION

More information

Submittal Sheet COUNTERSUNK HOLES SDG SPIRAL DUCT GRILLE 1 7/8" (47) + 1 1/4" (32) - 3/4" (19) ( DUCT OPENING ) END GASKET NOM. LENGTH - 3/4" (19) OPTIONAL AIR SCOOP AIR SCOOP (ROD OPERATOR) NOM. LENGTH

More information

Model 30/L/0. Model 30/S/0. Shortl Blades, 0 Deflection 3/4" Spacing. Model 35/S/0 Short Blades, 0 Deflection 1/2" Spacing

Model 30/L/0. Model 30/S/0. Shortl Blades, 0 Deflection 3/4 Spacing. Model 35/S/0 Short Blades, 0 Deflection 1/2 Spacing model 30 / 35 - Steel Return Grilles & Registers 0 Deflection 0 fixed blade deflection maximizes free area for low pressure loss and sound levels Potential line of sight into duct thru grille is acceptable

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS Airfoil Blade Return Air Models 71FH, 7145H 45 Deflection, 3/4" (19) Blade Spacing The airfoil blades are fixed at a 45 angle. This grille is vision proof when installed in a low or high sidewall location

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES Model 49-240 Model 48LL1 Model 49-280 Model 49-480 Model 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance.

More information

SECTION LOW PRESSURE DUCTWORK

SECTION LOW PRESSURE DUCTWORK SECTION 15841 LOW PRESSURE DUCTWORK PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07270 - Firestopping and Fire and Smoke Barrier Caulking. 2. 15260 - Vibration Isolation. 3. 15280 - Thermal Insulation

More information

EMAC 001 ACCESS PANEL

EMAC 001 ACCESS PANEL EMAC 001 ACCESS PANEL 900 x 600* 1200 x 600* Picture covers uneven edges Beaded can be taped and jointed for skimming Ensure the structural opening (panel size +10mm) is lined with timber or steel section.

More information

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver. - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS TruGroove Drywall A3 MOUNTING Ceiling INSTALLATION System Overview These instructions review how to install drywall trim versions of TruGroove recessed

More information

INSTALLATION, I O OPERATION & MAINTENANCE M A N U A L. Flowline. Architectural Linear Diffusers

INSTALLATION, I O OPERATION & MAINTENANCE M A N U A L. Flowline. Architectural Linear Diffusers INSTALLATION, I O M OPERATION & MAINTENANCE M A Flowline Architectural Linear Diffusers N U A L FLH Series: Horizontal High Throw FLV Series: Vertical Jet Throw www.nailor.com INSTALLATION INSTRUCTIONS

More information

Installation And Care Instructions. Vertical Honeycomb Shades

Installation And Care Instructions. Vertical Honeycomb Shades Installation And Care Instructions Vertical Honeycomb Shades Rev 5/2013 Table Of Contents Getting Started... 3 Parts Overview... 4 Materials Required... 5 Tools Required... 6 Outside Mount Installation...

More information

UPM 6X. UPM 6X Standard stock Tee socket sized for 5" schedule 40 or 80 Pipe. Page 1 of 8

UPM 6X. UPM 6X Standard stock Tee socket sized for 5 schedule 40 or 80 Pipe. Page 1 of 8 Page 1 of 8 UPM 6X A. TEE SOCKET: 6 O.D. PIPE SOCKET TO FIT OVER 5 SCHEDULE 40 OR 80 STEEL PIPE B. CROSS PIECE: 2 X 2 X 1/8, LENGTH DEPENDENT ON MODULE USED, SQ. TUBE 2 PLACES C. LONGITUDINAL: 2 X 2 X

More information

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS TruGroove Drywall A3 MOUNTING Ceiling INSTALLATION System Overview These instructions review how to install trimless drywall versions of TruGroove

More information

INSTALLATION AND CARE INSTRUCTIONS

INSTALLATION AND CARE INSTRUCTIONS INSTALLATION AND CARE INSTRUCTIONS Vertical Applications Honeycomb Shades 52 C8-10-3401 Rev 2/14 CONTENTS Introduction...2 Before You Begin...3 Vertical Application Parts Overview...4 Materials Required...5

More information

UPM 6X Custom. UPM 6X CUSTOM Standard stock Tee socket sized for 5" schedule 40 or 80 Pipe. Page 1 of 8

UPM 6X Custom. UPM 6X CUSTOM Standard stock Tee socket sized for 5 schedule 40 or 80 Pipe. Page 1 of 8 Page 1 of 8 UPM 6X Custom A. TEE SOCKET: 6 O.D. PIPE SOCKET TO FIT OVER 5 SCHEDULE 40 or 80 STEEL PIPE B. CROSS PIECE: 2 X 2 X 3/16, LENGTH DEPENDENT ON MODULE USED, SQUARE TUBE 2 PLACES C. LONGITUNDINAL:

More information

CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

CARRIER OVERHANG 1'-0 MAX PANEL LENGTH 3'-0 MIN - 16'-0 MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise) DETAIL 5 32 5 " 27 32 " 6" OPTIONAL FLAT RECESSED CLOSURE 1 1 4 " 17 32 " 1 25 32 " OPTIONAL BUTTERFLY CLOSURE CARRIER OVERHANG 1'-0" MAX CARRIER SPAN 4'-0" 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER

More information

Model 209 Fireback Replacement

Model 209 Fireback Replacement Model 209 Fireback Replacement Please read all the instructions before you begin the procedure. Confirm that you have all the necessary tools and materials. If you have any questions, technical support

More information

ORDERING INFORMATION:

ORDERING INFORMATION: LINEAR GRUV1. APPLICATION: Retail and commercial recessed ambient lighting CONSTRUCTION: Extruded aluminum housing and trim Die-formed, cold-rolled steel internal components and external housing OPTICS:

More information

metalworks Vector Assembly and Installation Instructions

metalworks Vector Assembly and Installation Instructions metalworks Vector Assembly and Installation Instructions 1. GENERAL 1.1 Product Description MetalWorks Vector is a downward accessible galvanized steel ceiling panel available in standard 24" x 24" size.

More information

*************************************************************************************************************

************************************************************************************************************* 15890 DUCTWORK ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 23 33 13 *************************************************************************************************************

More information

INSTALLATION INSTRUCTIONS GRILLE GUARD 09-ON DODGE RAM PART #

INSTALLATION INSTRUCTIONS GRILLE GUARD 09-ON DODGE RAM PART # INSTALLATION INSTRUCTIONS GRILLE GUARD 09-ON DODGE RAM PART # PARTS LIST: Qty Description Qty Description 1 Grille Guard 8 12-1.75mm x 35mm Hex Bolts 2 Brackets (for trucks without 22 12mm x 30.1mm OD

More information

INSTALLATION MANUAL STOREFRONT DOORS

INSTALLATION MANUAL STOREFRONT DOORS INSTALLATION MANUAL STOREFRONT DOORS www.aluflam-usa.com SYSTEM DESCRIPTION - Extruded and filled aluminum framing, tested and approved by UL - 3-3/8 frame depth - Clear, fire-rated safety glazing - Door

More information

4 Position the Suntile to the x tile s position and mark the felt around the square box flange. Then remove the Suntile

4 Position the Suntile to the x tile s position and mark the felt around the square box flange. Then remove the Suntile 4 Position the Suntile to the x tile s position and mark the felt around the square box flange. Then remove the Suntile 5 Using a sharp bladed knife, cut through the felt from corner to corner in an x

More information

#3 Domed Head Plow Bolt Standard Thread and Body Length

#3 Domed Head Plow Bolt Standard Thread and Body Length #3 Domed Plow Bolt Standard Thread and Body Length Flat vs Dome Plow Bolts Flat (per ASME B18.9) Domed Designs Supplied by Earnest (per Cat 1E44) Industry practice is to call a # 3 head plow bolt that

More information

3" [76.0mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

3 [76.0mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY WITH OPTIONAL S.S. S PLEASE READ PLEASE READ THESE INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING THE INSTALLATION! THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE A SPECIFIC GUIDE TO FOLLOW FOR THE INSTALLATION

More information

Legend W White B Bronze S Silver (Gray) K Black M Mill. Figure

Legend W White B Bronze S Silver (Gray) K Black M Mill. Figure Figure Description Part No. Additional Part Manual No. Color Code Page No. 1 Frame head N/A Not shown 2 Screen adaptor N/A Not shown 3 Frame jamb N/A Not shown 4 Frame sill N/A Not shown 5 Frame sill adaptor

More information

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY WITH OPTIONAL S.S. S PLEASE READ PLEASE READ THESE INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING THE INSTALLATION! THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE A SPECIFIC GUIDE TO FOLLOW FOR THE INSTALLATION

More information

Mach Wall Installation Instructions

Mach Wall Installation Instructions Mach Wall Installation Instructions Planning the Job Since Mach Wall is an innovative product that accomplishes 3 tasks at the same time (frame, insulate and drywall) and it replaces traditional framing,

More information

HZ301 & HZ321. Standard and Junior Flush Valve Installation Instructions

HZ301 & HZ321. Standard and Junior Flush Valve Installation Instructions TABLE OF CONTENTS Product Overview.. 2 How to Order.. 2 Product Specifications.. 2 Tools Required... 2 Safety Instructions. 3 Visual Check.. 3 Flush Pipe Installation 3 Hygihose Installation. 4 Duct Connection.

More information

Half Round 180 Displacement Diffuser

Half Round 180 Displacement Diffuser MANUAL INSTALLATION + SERVICE Half Round 80 Displacement Diffuser DR80 Series Revision #: 0 Issue Date: 03/2/4 204 Price Industries Limited. All rights reserved. HALF ROUND 80 DISPLACEMENT DIFFUSER INSTALLATION

More information

Driver/Left Top. Support Bracket

Driver/Left Top. Support Bracket PARTS LIST: 1 Grille Guard 8 10mm Lock Washers 1 Driver/Left Frame Bracket 8 10mm Hex Nuts 1 Passenger/Right Frame Bracket 2 8-1.25mm x 25mm Button Head Bolts 1 Driver/Left Bottom Support Bracket 2 8mm

More information

Installation Instructions

Installation Instructions Installation Instructions RAPID RIDGE STANDARD / 7 / METRIC Page Installation Considerations 3 Rapid Ridge Standard General Installation 4 Rapid Ridge Metric General Installation 5 Rapid Ridge 7 General

More information

SAE of 7 "R" (REGRESSED) POSITION "S" (SHIELDING AT TOP) POSITION. Tools Required

SAE of 7 R (REGRESSED) POSITION S (SHIELDING AT TOP) POSITION. Tools Required SAE 0 5/6'' Exposed TBar Ceiling FINISHED EDGE WITH JANGLE 90 IC CORNER KIT 5 7/6" 38mm 9/6'' Screw Slot TBar Ceiling "R" (REGRESSED) POSITION 6" CEILING OPENING "S" (SHIELDING AT TOP) POSITION SUPPORT

More information

REQUEST FOR INFORMATION

REQUEST FOR INFORMATION Ardmore, PA Atlantic City, NJ REQUEST FOR INFORMATION PROJECT: 1845 - Renaissance Hotel Renovations RFI NUMBER: 10.0 JONATHAN NEHMER & ASSOC ATTN: Lauren Maccherone Dacey 7361 Calhoun Place Suite 310 Rockville,

More information

HP-2 / HP-4 / HP-6 Ceiling to Wall Inside Corner Installation Instructions Overview

HP-2 / HP-4 / HP-6 Ceiling to Wall Inside Corner Installation Instructions Overview Overview Step 4 Mounting to Structure Page 6 Step 1 Mounting Locations & Rough-Ins Pages 2-3 Step 2 Identification & Preparation Page 4 Step 6 Securing Corner Joints Page 8 Step 3 Opening Luminaires Page

More information

Wall Mounted Rectangular Diffusers

Wall Mounted Rectangular Diffusers MANUAL INSTALLATION + SERVICE Wall Mounted Rectangular Diffusers DF / DF3 Series Revision #: 0 Issue Date: 03/25/4 204 Price Industries Limited. All rights reserved. INSTALLATION INSTRUCTIONS DF / DF3

More information

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.

More information

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section. SECTION 15800! AIR DISTRIBUTION PART 1! GENERAL 1.01 RELATED DOCUMENTS The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV

More information

AXIOM Classic Trim Installation Instructions

AXIOM Classic Trim Installation Instructions CEILING SYSTEMS AXIOM Classic Trim Installation Instructions 1 GENERAL 1.1 Description Axiom is a perimeter trim system designed for use with most of Armstrong s suspension systems. It is available through

More information

R6NC 6" LED Recessed Downlight: Universal New Construction Housing

R6NC 6 LED Recessed Downlight: Universal New Construction Housing Specifications/Features Housing/Mounting Specification grade 6" housing, 6-1/2" aperture. 6-5/8" Ceiling opening. 16 Gauge galvanized steel housing with die-cast aluminum heat sink. Requires minimum 3"

More information

MANUAL INSTALLATION. Linear Bar Grille - Heavy Duty LBPH/LBMH. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Linear Bar Grille - Heavy Duty LBPH/LBMH. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Linear Bar Grille - Heavy Duty LBPH/LBMH v000 Issue Date: 09/17/18 2018 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Overview...1 Before You Start...2

More information

IOM 004 Effective 3/29/04 Rev A. MULTI-VENT Laminar Flow Panels Installation Operation and Maintenance

IOM 004 Effective 3/29/04 Rev A. MULTI-VENT Laminar Flow Panels Installation Operation and Maintenance IOM 004 Effective 3/29/04 Rev A MULTI-VENT Laminar Flow Panels Installation Operation and Maintenance Contents Batten Arrangements...3 Slip-On Battens...4 Ceiling Opening...5 Installation...5 Hanger Bracket

More information

2540 E. Miraloma Way 1693 Rimpau Ave. Anaheim, Ca Corona, Ca PH: Fax:

2540 E. Miraloma Way 1693 Rimpau Ave. Anaheim, Ca Corona, Ca PH: Fax: Stocking Warehouse (Anaheim) Manufacturing (Corona) 2540 E. Miraloma Way 1693 Rimpau Ave. Anaheim, Ca. 92806 Corona, Ca. 92881 PH: 714-422-0760 Fax: 714-632-1685 Rectangular Duct & Fittings Spiral Pipe

More information

Hospital Grade Welded Ceiling System

Hospital Grade Welded Ceiling System MANUAL INSTALLATION Hospital Grade Welded Ceiling System HGWC Series v001 Issue Date: 08/14/18 2018 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Before You Start...1

More information

Acoustical Infill Panels

Acoustical Infill Panels Acoustical Infill Panels Assembly and Installation Instructions 1. GENERAL These installation instructions will explain and show the recommended installation methods for acoustical infill panels with-in

More information

Special thanks to everyone who helped design, build, install and test the prototype system: James Hendrickson, Ben Wurst, Mark Miller and Stacy Reed.

Special thanks to everyone who helped design, build, install and test the prototype system: James Hendrickson, Ben Wurst, Mark Miller and Stacy Reed. Special thanks to everyone who helped design, build, install and test the prototype system: James Hendrickson, Ben Wurst, Mark Miller and Stacy Reed. **Please read all instructions before beginning to

More information

Segmental ring types provided by F P McCann: Segments in stock are front bolted. Back bolted segments are available to order: Cross joint Corbel Ring

Segmental ring types provided by F P McCann: Segments in stock are front bolted. Back bolted segments are available to order: Cross joint Corbel Ring Building Manual for F P McCann `Smoothbore Shaft Linings with EPDM Gaskets (rev 04) (To be read in conjunction with the Segmental Shaft and Tunnel Safety Data Sheet) Segmental ring types provided by F

More information

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. International Version

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. International Version CEILING SYSTEMS Between us, ideas become reality Installing Suspended Ceilings International Version 1 Installing Armstrong Suspended Ceilings An Armstrong suspended mineral fiber ceiling is functional,

More information

INSTRUCTIONS AND REPAIR PARTS LIST

INSTRUCTIONS AND REPAIR PARTS LIST INSTRUCTIONS AND REPAIR PARTS LIST Model No. F60MB F60MB+20 Description and approximate capacities 2 Shells, 64 bushel, 1.6 Tons (54.5 kg) 3 Shells, 84 bushel, 2.1 Tons (1909.1 kg) F60MB, F60MB+20 MBSLGT,

More information

Assembly & Installation Guide (Metric)

Assembly & Installation Guide (Metric) Assembly & Installation Guide (Metric) INFRASTRUCTURE FOR LIFE RS Technologies www.rstandard.com Email Toll Free Phone Fax info@grouprsi.com +1 877 219 8002 +1 403 219 8000 +1 403 219 8001 2421 37th Avenue

More information

APPENDIX A, UMC STANDARD 6-5 STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS

APPENDIX A, UMC STANDARD 6-5 STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS Sealing of fibrous glass duct board to the sheet metal sleeve must be made with glass fabric and mastic, except where operating pressure is less than

More information

STEP 1 : DESTROYER FRONT BUMPER INSTALL GATHER YOUR TOOLS AND LAY OUT YOUR PARTS... *shorty bumper to show hardware* Tools Required:

STEP 1 : DESTROYER FRONT BUMPER INSTALL GATHER YOUR TOOLS AND LAY OUT YOUR PARTS... *shorty bumper to show hardware* Tools Required: DESTROYER FRONT BUMPER INSTALL JL STEP 1 : GATHER YOUR TOOLS AND LAY OUT YOUR PARTS... Tools Required: - Utility knife - 11/16 Deep socket - Ratchet - 11/16 Crescent wrench - Ratchet Extension - 1/4 socket

More information

INSTALLATION INSTRUCTIONS GRILLE GUARD RAM 1500 PART # 5058/5058-2

INSTALLATION INSTRUCTIONS GRILLE GUARD RAM 1500 PART # 5058/5058-2 INSTALLATION INSTRUCTIONS GRILLE GUARD PART # 5058/5058-2 PARTS LIST: Qty Description Qty Description 1 Grille Guard 8 12-1.75mm x 35mm Hex Bolts 2 Upper Frame Mounting s (for trucks without tow hooks

More information

Low Headroom Rear Mount TorqueMaster

Low Headroom Rear Mount TorqueMaster Low Headroom Rear Mount Supplemental Instruction Insert This supplemental installation instruction is to be used as a supplement to the main Installation Instruction and Owner s Manual provided with the

More information

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing.

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing. SECTION 15841 LOW PRESSURE STEEL DUCTWORK PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15180 - Mechanical Systems Insulation. 2. 15940 - Outlets (HVAC). 3. 15991 - Testing and Balancing. 1.02 SUBMITTALS

More information

4-lite Patio Door. Installation Instructions

4-lite Patio Door. Installation Instructions 4-lite Patio Door Installation Instructions IMPORTANT: Read the instructions and familiarize yourself with the door parts and pieces before beginning assembly and installation. Note: Only the 5-0 x 6-8

More information

ROMAN AND. Roller Lift System Continuous Cord Loop GETTING STARTED BRACKET INFORMATION INSIDE MOUNT. A few simple tools are required:

ROMAN AND. Roller Lift System Continuous Cord Loop GETTING STARTED BRACKET INFORMATION INSIDE MOUNT. A few simple tools are required: ROMAN AND WOVEN WOOD SHADES Roller Lift System Continuous Cord Loop GETTING STARTED BRACKET INFORMATION A few simple tools are required: The brackets you received with your product are REQUIRED for proper

More information

Insolroll Clutch Operated Shades Installation Instructions Installation Instructions

Insolroll Clutch Operated Shades Installation Instructions Installation Instructions All clutch operated shades are shipped fully assembled and ready for installation. Mounting screws are not provided. Screws for chain guide installation to meet the child safety standards are provided.

More information

ELEPHANT DOOR SYSTEMS SERIES E1200

ELEPHANT DOOR SYSTEMS SERIES E1200 INSTALLATION INSTRUCTIONS ELEPHANT DOOR SYSTEMS SERIES E1200 Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com AVDB3096 03.13 TABLE OF CONTENTS SUBJECT PAGE GENERAL INSTALLATION

More information

AXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL

AXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL AXIOM Classic Trim Assembly and Installation Instructions 1. GENERAL 1.1 Description Axiom Classic Trim is a perimeter trim system designed for use with a variety of Armstrong suspension systems. Classic

More information

AXIOM Classic Trim. Assembly and Installation Instructions

AXIOM Classic Trim. Assembly and Installation Instructions AXIOM Classic Trim Assembly and Installation Instructions 1. GENERAL 1.1 Description Axiom Classic Trim is a perimeter trim system designed for use with a variety of Armstrong suspension systems. Classic

More information

Storefront Installation Guide

Storefront Installation Guide Storefront General Notes: 1. Check Contract Documents and Shop Drawings. Understand and clarify any Field Verify Notes and approvals of drawings and products to be familiar with the project. Installation

More information

Standard Pole Mount Parabolic Antenna Mounting Instructions 3 ft. (90cm) & 4 ft. (120cm)

Standard Pole Mount Parabolic Antenna Mounting Instructions 3 ft. (90cm) & 4 ft. (120cm) 495 R Billerica Ave. N. Billerica, MA 01862 USA Tel: (978) 459-8800 Fax: (978) 459-3310 / 8814 www.radiowavesinc.com email: sales@radiowavesinc.com Standard Pole Mount Parabolic Antenna Mounting Instructions

More information

Tools needed. Supplies Needed

Tools needed. Supplies Needed Installation Guide Key System Components Main beam Cross tee Tools needed Chalk line Drill (cordless) ¼" drill bit Hammer Miter saw Pencil String line(s) Stud finder Tape measure ½" to 1" wood chisel Calculator

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BUILDERS CHOICE FRAMED Bypass Door Model: L0516 (Tub Height), L0517 (Shower Height) Rev. 09.20.13 INSTALLATION NOTES: Unpack your unit carefully and inspect for freight damage.

More information

Nailbiter Premium Ship Auger Bits. RESI-MASTER Heavy-Duty Ship Augers

Nailbiter Premium Ship Auger Bits. RESI-MASTER Heavy-Duty Ship Augers Nailbiter Premium Ship Auger Bits Dual-Helix construction with twin cutting edges for faster and smoother drilling action, even through nail-embedded timbers Full body, dual induction heat treatment ensures

More information

R4NCIE Intellect Enabled 4" LED Recessed Downlight: Universal New Construction Housing

R4NCIE Intellect Enabled 4 LED Recessed Downlight: Universal New Construction Housing R4NCIE Intellect Enabled 4" LED Recessed Downlight: Universal New Construction Housing Specifications/Features Intellect Control Intellect-enabled luminaires integrate occupancy/vacancy sensing and light

More information

Owner's Manual & Assembly Instructions

Owner's Manual & Assembly Instructions Owner's Manual & Assembly Instructions PK01 BASE KIT Model No. FDN106 71706011 CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. FOR SAFETY SAKE,

More information

SunTrackerTwo Preparation

SunTrackerTwo Preparation TOLL FREE:(888)29-2705 FAX:(941)77-9460 info@eco-smart.com SunTrackerTwo Preparation Cutting Holes and Preparing Curbs T.G.I Or Truss CIRALIGHT INSTALLATION MANUAL Page 1 Cutting Holes and Preparing Curbs

More information

Models: SC675A, SC679A/B/D/E/F/G/H/J, SC681A, SC684A/B/D/E/F, SC688A, SC699A/B, SC886A/B/D/E, SC887A/B, SC888A/B/D/E/F, SC899A/B/D/E

Models: SC675A, SC679A/B/D/E/F/G/H/J, SC681A, SC684A/B/D/E/F, SC688A, SC699A/B, SC886A/B/D/E, SC887A/B, SC888A/B/D/E/F, SC899A/B/D/E Models: SCA, SCA/B/D/E/F/G/H/J, SCA, SCA/B/D/E/F, SCA, SCA/B, SCA/B/D/E, SCA/B, SCA/B/D/E/F, SCA/B/D/E Upper Casting Assembly 0 0 0 0 0 Pro STAR Industries, Inc -00--0 www.prostarindustries.com Models:

More information

Dura-Lock Roof System

Dura-Lock Roof System DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.

More information

R4NC 4" LED Recessed Downlight: Universal New Construction Housing

R4NC 4 LED Recessed Downlight: Universal New Construction Housing R4NC 4" LED Recessed Downlight: Universal New Construction Housing Specifications/Features Housing/Mounting Specification grade 4" New Construction housing, 4-3/4" aperture; 4-7/8" ceiling opening. 16

More information

HONEYCOMB SHADES with Continuous Cord Loop

HONEYCOMB SHADES with Continuous Cord Loop HONEYCOMB SHADES with Continuous Cord Loop GETTING STARTED BRACKET INFORMATION A few simple tools are required: The brackets you received with your product are REQUIRED for proper installation. Brackets

More information

AIR ACTIVATED MODULAR INLET

AIR ACTIVATED MODULAR INLET AIR ACTIVATED MODULAR INLET 345678903456789034567890 345678903456789034567890 MI4 345678903456789034567890 345678903456789034567890 Each MI4 includes: - Modular Inlet - Counterweight - Hardware Package

More information

Panel Installation Instructions

Panel Installation Instructions EXTREMELY IMPORTANT INFORMATION PLEASE READ ENTIRE PACKET! Warranty Is Void If Panels Not Installed According to Instructions 1. WARNINGS & SPECIAL NOTES 1.1 Keep panels 24 from Heaters and shield Radiant

More information

Please read these instructions thoroughly prior to beginning the Acrovyn Z-Clip Wall Panel installation!

Please read these instructions thoroughly prior to beginning the Acrovyn Z-Clip Wall Panel installation! Please read these instructions thoroughly prior to beginning the Acrovyn Z-Clip Wall Panel installation! This instruction sheet is intended to provide a specific guide to follow for the installation of

More information

INSTALLATION INSTRUCTIONS FOR HAND OPERATED SILENT STEEL ADC HEAVY DUTY CURTAIN TRACK MODELS: 280, 281, 282, 280-A, 283-N, 283-R

INSTALLATION INSTRUCTIONS FOR HAND OPERATED SILENT STEEL ADC HEAVY DUTY CURTAIN TRACK MODELS: 280, 281, 282, 280-A, 283-N, 283-R INSTALLATION INSTRUCTIONS FOR HAND OPERATED SILENT STEEL ADC HEAVY DUTY CURTAIN TRACK MODELS: 280, 281, 282, 280-A, 283-N, 283-R I. SUSPENDED INSTALLATIONS 1. Lay the two track halves on the floor with

More information

Privacy Wall Glass Selections - Polished Edge Slider Door

Privacy Wall Glass Selections - Polished Edge Slider Door Privacy Wall Glass Selections - Polished Edge Slider Door 3/6" HEX BIT PUTTY KNIFE #2 ACR BIT SUCTION CUP HOLDERS DOOR LEAF: Satin Tempered Clear Tempered LOCTITE 425 SIDE LIGHT ETCHED GLASS STYLES: Satin

More information

Copyright 2009, Seymour Products LLC, All rights reserved. GET THE SCREEN, KEEP THE SOUND

Copyright 2009, Seymour Products LLC,   All rights reserved. GET THE SCREEN, KEEP THE SOUND GET THE SCREEN, KEEP THE SOUND There are three boxes inside the outer box. The tube contains the screen, the large box contains the frame pieces, and the small box contains the small items. The corner

More information

10-1.5mm x 40mm Hex Bolt 1 Driver/Left Front Inner Support Bracket (2WD & 4WD Vehicles W/O Skid Plate Only) 2

10-1.5mm x 40mm Hex Bolt 1 Driver/Left Front Inner Support Bracket (2WD & 4WD Vehicles W/O Skid Plate Only) 2 PARTS LIST: 1 Driver/Left sidebar 4 12mm x 32mm OD x 3mm Flat Washer 1 Passenger/Right sidebar 4 12mm x 24mm OD x 2.5mm Flat Washer 1 Driver/Left Mounting Bracket 6 12mm Lock Washers 1 Passenger/Right

More information

REGISTERS, GRILLES & DIFFUSERS

REGISTERS, GRILLES & DIFFUSERS 2012 REGISTS, GRILLES & DIFFUSS AUTHORIZED DISTRIBUTOR LIST PRICING HCPL-42 rev3 EFFECTIVE: JAN 9, 2012 REGISTS, GRILLES & DIFFUSS TMS & CONDITIONS SALE OF ALL GOODS ARE EXPRESSLY CONDITIONED UPON THE

More information

A - Railing Frame Material Specifications

A - Railing Frame Material Specifications A - Railing Frame Material Specifications NOTE: We strongly recommend stainless steel for exterior applications. R-1 8/1/02 B Stainless Steel Spacers (For Horizontal Railing Double Post End Post using

More information

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8 [161.9mm] PLEASE READ PLEASE READ THESE INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING THE P-RSAN-INT INSTALLATION! THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE A SPECIFIC GUIDE TO FOLLOW FOR THE INSTALLATION OF THIS

More information

Installing your new Bevella Top. L Shaped Countertop with Joints No Finished Ends (Fits Between Four Walls)

Installing your new Bevella Top. L Shaped Countertop with Joints No Finished Ends (Fits Between Four Walls) Installing your new Bevella Top L Shaped Countertop with Joints No Finished Ends (Fits Between Four Walls) Bevella RTI Countertops are engineered and manufactured to the highest quality standards, built

More information

(2) 12mm x 40mm Bolt Plate (long) pictured w/plastic retainer. (6) 12mm x 40mm Bolt Plate (short) Support Bracket Driver/left Front

(2) 12mm x 40mm Bolt Plate (long) pictured w/plastic retainer. (6) 12mm x 40mm Bolt Plate (short) Support Bracket Driver/left Front PARTS LIST: 1 Driver/left Running Board w-1 Backing 8 12mm Plastic Retainers 1 Passenger/right Running Board w-1 Backing 8 12mm x 32mm x 3mm Flat Washers 2 2 inch tall rubber backing (SX & Limited only)

More information

HALL 1 & HALL 4 RESTROOM FINISH UPGRADE 100 SOUTH WEST TEMPLE, SLC, UT QUOTE # SLP42848 AUGUST 29, 2017 CONSTRUCTION DOCUMENTS ABBREVIATIONS

HALL 1 & HALL 4 RESTROOM FINISH UPGRADE 100 SOUTH WEST TEMPLE, SLC, UT QUOTE # SLP42848 AUGUST 29, 2017 CONSTRUCTION DOCUMENTS ABBREVIATIONS DRAWING INDEX HALL 1 & HALL 4 BID INFORMATION RESTROOM 100 SOUTH WEST TEMPLE, SLC, UT 84111 QUOTE # SLP42848 AUGUST 29, 2017 CONSTRUCTION DOCUMENTS ABBREVIATIONS CONSULTANTS OWNER SYMBOL LEGEND VICINITY

More information

Unit No. 4400, 4500 Classic Frameless Sliding Tub/Shower Enclosure INSTALLATION INSTRUCTIONS

Unit No. 4400, 4500 Classic Frameless Sliding Tub/Shower Enclosure INSTALLATION INSTRUCTIONS Unit No. 4400, 4500 Classic Frameless Sliding Tub/Shower Enclosure INSTALLATION INSTRUCTIONS MAINTENANCE: Two primary materials are used to manufacture your new Basco enclosure: tempered glass and anodized

More information

CORS-AIR STOCK CATALOG. E.M. CORSON AND A SSOCIATES, INC. Manufacturers Representative.

CORS-AIR STOCK CATALOG. E.M. CORSON AND A SSOCIATES, INC. Manufacturers Representative. CORS-AIR E.M. CORSON AND A SSOCIATES, INC. Manufacturers Representative STOCK CATALOG Edi on 3.0 info@cors-air.com www.cors-air.com BROWARD COUNTY 2865 S. W. 30th Avenue Pembroke Park, FL 33009 Phone (954)

More information

R4NC 4" LED Recessed Downlight: Universal New Construction Housing

R4NC 4 LED Recessed Downlight: Universal New Construction Housing R4NC 4" LED Recessed Downlight: Universal New Construction Housing Specifications/Features Housing/Mounting Specification grade 4" New Construction housing, 4-3/4" aperture; 4-7/8" ceiling opening. 16

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 230553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 SUBMITTALS A.

More information

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL The ProTEC panels are manufactured with grooves on all four sides to accept the steel components. This grooving applies to the regular panel whose

More information

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools...

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools... INS-88.300-0A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE 1. Verify Curb Installation... 2 2. Required Installation Tools... 2 3. Unpacking the KSR... 3 4. Attach KSR Bottom Rail to Curb... 5 5. Attach

More information