Double Channel Loop Detector
|
|
- Flora Gilmore
- 5 years ago
- Views:
Transcription
1 Double Channel Loop Detector NBLD-00 series The NBLD00 is a double channel inductive loop detector, designed for parking and vehicle access control. The function of the detector is to detect vehicle presence by means of an inductance change caused by the vehicle passing over a wire loop buried under the road surface. Product Series NBLD-00 NBLD-0 NBLD-0 NBLD-0
2 Feature. Compact Size: the compact and well engineered housing combined with all the industry requirements regarding features and functionality allows this detector to be incorporated into any new or existing vehicle detection system.. Diagnostic Capabilities: Comprehensive diagnostics capabilities allow for accurate diagnosis of loop and installation problems.. Selectable Presence Time: The output of the presence relay can be selected to limit a detect output to a fixed time(time>0 minutes) while a vehicle remains on the loop.. Sensitivity setting: The sensitivity settings allow for finer adjustment of the detection level. Frequency setting: The frequency settings provide greater flexibility in preventing crosstalk in multi-loop applications.. Reset Switch : The reset switch enables the detector to be manually reset during commissioning and testing.this results in the detector re-tuning the sensing loop and becoming ready for vehicle detection. Two separate output relays: Presence Relay A is presence output, can be extended for 0,,,,0,,0 or 0 seconds. Pulse Relay B, programmable with external 0 way DIP switches, provide presence, pulse on entry, pulse on exit, or failed output. Specification Self-turning range: 0-000uh Voltage: -VDC or -0VAC Relay output: presence relay /pulse reply Working temperature: Frequency: steps switch, 0-0KHz Response time: turn on 0-0MS, turn off 0-0NS Reset: reset by push button on front of enclosure Humidity: up to % relative humdiity without consideration Sensitivity: ways selectable, highest: 0.00% DL/L, Lowest:.% DL/L Loop wire: more than 0 meters requires the use of a core shielded cable, do not exceed 0 meters distance between control box and loop Size: mm*mm*0mm
3 Connections: PIN NBLD-00 NBLD-0 NBLD-00/0 Connection 00-0V AC -VADC V/V V AC Neutral Ch Relay COM Ch Relay N.O Chassis Ground Ch Relay COM Ch Relay N.O -VADC.V 胶体 / 密封 / 开口 :.V.V, 密封 :.V, 开口 : 0A 0V 0.V 0.0V V/.mA Ch, -mv/ /V( 以 密封 :.V, 开口 :.V power Ch, 密封 :.V 0, 自定义 : ~V PIN NBLD-0 NBLD-0 NBLD-0/0 Connection 00-0V AC -VADC V/V V AC Neutral Ch Relay COM Ch Relay N.O Chassis Ground Ch Relay COM Ch Relay N.O -VADC V/V 密封 :.V.V.V, 密封 :.V, 开口 : 0A 0V 0.V 0.0V V/.mA Ch, -mv/ /V( 以 0 密封 :.V, 开口 :.V power Ch, 自定义 : ~V
4 Instruction:.Power Led: RED power LED indicates Power ON.CH Detecting Led:Continuously On: Indicates vehicle detection..blinking slowly: Indicates loop is short circuit or the number of twists after the loop is not enough..blinking fast: Indicates loop is open circuit or too many twists after the loop..ch Detecting Led:Continuously On: Indicates vehicle detection..blinking slowly: Indicates loop is short circuit or the number of twists after the loop is not enough. Switch instruction:.sensitivity and frequency of the loop can be adjusted by -way dip switch and 0-way dip switch setting..user can select different setting by changing the setting of the dip-switch to different modes as in the dip-switch setting tables below. Dip switch, and for CH sensitivity selection with 0. being the least sensitive and 0.0 being the most sensitive..dip switch, and for CH sensitivity selection with 0. being the least sensitive and 0.0 being the most sensitive. Installation Notes:.When installation, please keep the product plug and socket in the vertical direction
5 Loop coil details Formal national standard loop detector the coil, High temperature wire, High temperatures resistant, There are many colors. (There are some vendor using ordinary tinned wire posing as high-temperature wire sales, the kind of low-cost wire, but the laying of a long-term use of hidden dangers, please buyers attention to distinguish.) Which are tinned copper wire, different specifications, different brass wire diameter, teflon outer sheath high temperature waterproof anti-corrosion, dedicated to the loop detector of the coil.(this kind of wire often used in high temperature environment, in order to prevent high temperature oxidation. State regulations and industry specifications using tinned copper wire as a conductor, tinned copper wire outside the silver-white metallic luster, cut open inside is pure copper. So please buyers don t have to question whether the fine copper. Accessories for optional In-kind Shooting LD-A In-kind Shooting HAR- LD-B In-kind Shooting LD- In-kind Shooting Shenzhen Noble Opto Co.,Ltd Tel: 0-/
Single Channel Loop Detector
Single Channel Detector NLD-0 series The NLD0 is a single channel inductive loop detector, designed for parking and vehicle access control. The function of the detector is to detect vehicle presence by
More informationDual Channel Traffic/Parking Detector User Guide
Dual Channel Traffic/Parking Detector User Guide Installation Manual LD-200 Rev A Dual Channel Vehicle detector LD-200 Page 1 of 4 I Connections LD-200 Dual Channels Traffic Detector User Guide Pin LD-200
More informationSingle Channel Loop Vehicle detector User Manual
Single Channel Loop Vehicle detector User Manual 1 Introduction CE-L02-J9 is a single channel digital inductive loop vehicle detector. It is used to identify the presence of vehicle by means of an inductive
More informationMD12-2 Metal Loop Detector
MD12-2 Metal Loop Detector Features Supply 12VDC Adjustable sensitivity (8 levels via dip switch) 2 x Relay outputs (each can be configured individually) Power up and loop activation LED indicator. Industry
More informationUSER MANUAL ULD 910. October 2003 Revision: 03. Single Channel Vehicle Detector ULD 910. Part Number: MIC
Single Channel Vehicle Detector ULD 910 USER MANUAL Part Number: MIC0302004 ULD 910 October 2003 Revision: 03 I N D E X PAGE Detector Commissioning... 1 Frequency... 1 Sensitivity... 1 Automatic Sensitivity
More informationOperations Manual. Model NT11 & NT11-E. June 18 th 2002
Operations Manual Model NT11 & NT11-E June 18 th 2002 3609 North 44 th Street Phoenix, AZ 85018-6023 Internet: www.northstarcontrols.com Fax: (941) 426-0807 Tel: (941) 426-6396 Manual Contents Glossary
More informationInductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
More informationSingle Channel Loop Detector
Single Channel Loop Detector Model - LD106 Series The LD106 is an ultra low power single channel inductive loop detector designed for parking and access control applications. The LD106 can be configured
More informationDual Channel Vehicle Detector ULD 920 USER MANUAL Part Number: MIC ULD 920
Dual Channel Vehicle Detector ULD 920 USER MANUAL Part Number: MIC0302036 ULD 920 October 2003 Revision: 03 I N D E X PAGE Detector Commissioning... 1 Frequency... 1 Sensitivity... 1 Automatic Sensitivity
More informationFG2 TWO-CHANNEL DETECTOR
FG TWO-CHANNEL DETECTOR. DIMENSIS AND ELECTRIC CNECTIS ENGLISH 4 VDC 4 Vdc power supply 3 4 5 6 7 8 9 0 Loop contact Loop contact Loop Loop Dimensions in mm. GENERAL INFORMATI Applications: control of
More informationSingle Channel Loop Detector
Single Channel Loop Detector Model - LD113 Series The LD113 is a single channel inductive loop card detector designed for parking and access control applications. The detector is connected to an inductive
More informationSingle Channel Loop Detector
Single Channel Loop Detector Model - LD116 The LD116 is a single channel inductive loop card detector designed for parking and access control applications. The detector is connected to an inductive loop
More informationShort form User Manual
Nortech Detection Pty Ltd Unit1, Bldg 5, Forest Central Business Park, 49 Frenchs Forest Road, Frenchs Forest NSW 2086 PO Box 6011, Frenchs Forest DC, NSW 2086 Tel: 02 8977 4047 Fax: 02 9475 4742 email:
More informationWith Audible Detect Signal
T-100 SERIES SINGLE CHANNEL SHELF MOUNT DETECTOR Meets and exceeds NEMA TS 1 specification. Six front panel DIP switches provide: Seven levels of sensitivity plus off. Presence or Pulse mode. Four loop
More informationSingle Channel Loop Detector
Single Channel Loop Detector Model - LD160 Series The LD160 is a single channel inductive loop detector designed for traffic control applications. The detector is connected to an inductive loop mounted
More informationUSERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS
We open up New Horizons USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS APPLICATION The MATRIX is a Digital Inductive Loop Detector used for the detection of vehicular traffic. The MATRIX is the ideal
More information601/602 Series Inductive Loop Detector
601/602 Series Inductive Loop Detector Installation Guide Sarasota Series Detectors 1 Copyright 2009 Peek Traffic Corporation Printed in the USA. All rights reserved. Information furnished by Peek is believed
More informationSPECIAL SPECIFICATION 6004 Digital Card Rack Inductive Loop Detector Assembly
2004 Specifications SPECIAL SPECIFICATION 6004 Digital Card Rack Inductive Loop Detector Assembly 1. Description. Furnish and install a digital card rack inductive loop detector assemblies. 2. Materials.
More informationBEA s digital inductive single loop solution
BEA s digital inductive single loop solution Matrix2-S With more standard features than any other loop detector on the market, the Matrix2-S has the flexibility, compatibility and performance to maximize
More informationULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128
ULT-MVP ULTRALOOP O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com
More informationULT-DIN O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128
O P E R A T I N G I N S T R U C T I O N S ULT-DIN ULTRALOOP V E HI C L E L O O P DETECTOR 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com
More informationUSERS GUIDE MATRIX P/N SINGLE DIGITAL INDUCTIVE LOOP SENSOR
USERS GUIDE MATRIX P/N 17500001 SINGLE DIGITAL INDUCTIVE LOOP SENSOR APPLICATIONS The MATRIX Digital Inductive Loop Detector is the ideal solution for parking barrier control, motorized gates and doors,
More informationSingle Channel Loop Detector
Single Channel Loop Detector Model LD120T Series The LD120T is a series of single channel inductive loop detectors. The use of microprocessor and surface mount technology enables a large number of functions
More informationTECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM
TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM THIS MANUAL IS INTENDED FOR FOREMEN AND TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, OPERATION AND MAINTENANCE
More informationPD132 Loop Detector Specification
PD132 Loop Detector Specification (Version 1.00) Content 1. Application... 3 2. Technical Data... 3 3 Wiring Diagram... 3 4 Use and operational... 4 4.1 Frequency adjust... 4 4.2 Sensitivity adjust...
More informationAGP-0230 USER MANUAL AMANO
This document is for information only and unless otherwise indicated it is not to form part of any contract. In accordance with the manufacturer s policy of continually updating and improving design, specifications
More informationSPECIAL SPECIFICATION 1257 Digital Card Rack Non-Invasive Micro Loop Detector Assembly (8 Slot Rack)
1993 Specifications CSJ 0924-06-147, etc. SPECIAL SPECIFICATION 1257 Digital Card Rack Non-Invasive Micro Loop Detector Assembly (8 Slot Rack) 1. Description. This Item shall govern for furnishing, and
More informationFLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR
FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR 1. Introduction The FLUX 11 is a single channel plug-in inductive loop detector designed for vehicle access applications, and interfaces
More informationOperating Instructions
ULT-PLG ULTRALOOP Vehicle Loop Detector Operating Instructions CAUTIONS AND WARNINGS CE REQUIREMENT: Use EMX Pre-formed loops with built-in surge suppression for CE compliance. Connect shield on lead in
More informationOperating Instructions
UltraDTEK Vehicle Loop Detector Operating Instructions PRODUCT OVERVIEW The UltraDTEK vehicle loop detector is plug-in compatible with Elite OmniControl TM board operators and other Elite A ELD enabled
More informationInductive Loop Detector
Naztec Operations Manual For Inductive Loop Detector Model 722TXC TS1/TS2 April 2003 Published by: Naztec, Inc. 820 Park Two Drive Sugar Land, Texas 77478 Phone: (281) 240-7233 Fax: (281) 240-7238 Copyright
More informationMFJ-249B HF/VHF SWR ANALYZER
TABLE OF CONTENTS MFJ-249B... 2 Introduction... 2 Powering The MFJ-249B... 3 Battery Installation... 3 Alkaline Batteries... 3 NiCd Batteries... 4 Power Saving Mode... 4 Operation Of The MFJ-249B...5 SWR
More informationMODEL L-1200 SERIES OPERATION MANUAL
Reno A & E Telephone: (775) 826-2020 4655 Aircenter Circle Facsimile: (775) 826-99 Reno, Nevada 89502 Internet: www.renoae.com USA e-mail: contact@renoae.com MODEL L-200 SERIES OPERATION MANUAL Built-in
More informationDatasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C
Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P - 4-20mA output, default range supplied 0-100 C ENGLISH The TX203P RTD in-head mounted temperature transmitter connects
More informationLMD622 and LMD624 Series
LMD622 and LMD624 Series Inductive Loop Monitor THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE LMD622, LMD622T, LMD624, LMD624H, and LMD624T SERIES INDUCTIVE LOOP MONITOR. REVISION: MARCH 2012 pn 888-062X-001
More informationSMARTSCAN INFORMATION
SMARTSCAN INFORMATION SS SLC NOV05 SLC2 and SLC4 SAFETY INDUCTIVE LOOP CONTROLLERS INSTALLATION GUIDE Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954,
More informationSPECIAL SPECIFICATION 8590 Emergency Vehicle Traffic Signal Priority Control System
2004 Specifications CSJ 0002-01-074, etc. SPECIAL SPECIFICATION 8590 Emergency Vehicle Traffic Signal Priority Control System 1. Description. This Item governs the furnishing and installation of emergency
More informationEGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
EGCW Converter for Electromagnetic Flowmeter GENERAL MAGMAX EGCW is the high-performance separate type converter for electromagnetic flowmeters with the compact housing. Improved self-diagnostic functions
More informationThank you for purchasing the Ameritron SDA-100 Antenna
Thank you for purchasing the Ameritron SDA-100 Antenna When properly installed this antenna will provide continuous coverage of 3.5 to 30 MHz with a 6' whip, also 6.0 to 60 MHz without a whip. Installation
More informationMFJ-219/219N 440 MHz UHF SWR Analyzer TABLE OF CONTENTS
MFJ-219/219N 440 MHz UHF SWR Analyzer TABLE OF CONTENTS Introduction...2 Powering The MFJ-219/219N...3 Battery Installation...3 Operation Of The MFJ-219/219N...4 SWR and the MFJ-219/219N...4 Measuring
More informationInstallation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY
CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CLASS MODEL SERIAL HP Installation Manual Use this manual for circuit
More informationInstruction Manual Veritest
Instruction Manual Veritest 4.2-1 - The Veritest 4.2 is a simple eddy current test instrument. It is designed for the detection of flaws in tubular and wire product for in-line applications where end suppression
More informationIMC-316P Hardware Manual for model IMC-316P-X-D
IMC-316P Hardware Manual for model IMC-316P-X-D Pub 352r0 A publication of 1050 Highland Drive Ann Arbor, Michigan 48108 Phone: (734) 665-5473 Fax: (734) 665-6694 www.whedco.com 2000 Whedco Incorporated,
More informationRatchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj
Ratchet Relay Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation at each pulse input
More informationBULLETIN # B
Page 1 of 9 BULLETIN # B-18-2002 From: Parts and Service Division Date: February 14, 2002 To: All Authorized Service Agencies SUBJECT: Convection Oven Controller Troubleshooting MODELS AFFECTED: All Garland
More informationJC-5 4KW PEP, 1KW RMS AUTO ANTENNA COUPLER
JC-5 4KW PEP, 1KW RMS AUTO ANTENNA COUPLER 1) DIRECTLY CONTROLLED BY ICOM, ALINCO & KENWOOD. 2) INDEPENDENT CAPACITOR INPUT AND OUTPUT BLOCKS! 3) 3 mm COIL WIRE & INTERNAL FAN FOR THE BIG COILS! 4) DIPPED
More informationMODEL T-110 SERIES OPERATION MANUAL
Reno A & E Telephone: (775) 86-00 4655 Aircenter Circle Facsimile: (775) 86-9191 Reno, Nevada 8950 Internet: www.renoae.com USA e-mail: contact@renoae.com MODEL T-110 SERIES OPERATION MANUAL Single Channel
More informationInductive Proximity Sensor
Inductive Proximity Sensor Linear Proximity Sensor with High-accuracy Resolution Resolution is 0.05% of the maximum sensing distance. The model with a sensing distance of 1.2 mm ensures a resolution of
More informationIRT Eurocard. Type AG-738. Stereo Audio Phase / Failure Detector
I R T Electronics Pty Ltd A.B.N. 000 7 6 Hotham Parade, ARTARMON N.S.W. 06 AUSTRALIA National: Phone: (0) 7 Fax: (0) 7 International: +6 7 +6 7 Email: sales@irtelectronics.com Web: www.irtelectronics.com
More informationMODEL P-1400 OPERATION MANUAL. Four Loop Inputs, Two Vital Outputs, and One Vital Input
Reno A & E 4655 Aircenter Circle Reno, NV 89502-5948 USA Telephone: (775) 826-2020 Facsimile: (775) 826-99 Website: www.renoae.com E-mail: contact@renoae.com MODEL P-400 OPERATION MANUAL Four Loop Inputs,
More informationPROMUX Distributed MODBUS I/O Modules Catalog and Design Guide
PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 12/03/2012 V11.0 P.O.Box 164 Seven Hills 1730 NSW AUSTRALIA Tel: +61 2 96248376 Fax: +61 2 9620 8709 Email: proconel@proconel.com Web: www.proconel.com
More informationFour Channel Inductive Loop Detector
Naztec Operations Manual For Four Channel Inductive Loop Detector Model 724/224 April 2003 Published by: Naztec, Inc. 820 Park Two Drive Sugar Land, Texas 77478 Phone: (281) 240-7233 Fax: (281) 240-7238
More informationPhoto-electric Amplifier ISG-A123 1-channel automatic amplifier
Photo-electric Amplifier -channel automatic amplifier Amplifier with modulated infrared light Range up to 25 m (82 ft) Automatic Level Control (ALC) according to assembly distance and direction Test function
More informationRME1-RME1BT INSTRUCCIONES DE INSTALACION INSTALLATIEVOORSCHRIFTEN INSTRUCTIONS D INSTALLATION ИНСТРУКЦИИ ПО УСТАНОВКЕ ISTRUZIONI DI INSTALLAZIONE
8 027908 339119 D811642_01 23-05-08 RILEVATORE DI VEICOLI A SPIRE VEHICLE LOOP DETECTOR DETECTEUR DE VÉHICULES A BOUCLE INDUCTIVE INDUKTIONSSCHLEIFEN-DETEKTOR ZUR DETEKTION VON FAHRZEUgEN DETECTOR DE VEHÍCULOS
More informationEECS 318 Electronics Lab Laboratory #2 Electronic Test Equipment
EECS 318 Electronics Lab Laboratory #2 Electronic Test Equipment Objectives: The purpose of this laboratory is to acquaint you with the electronic sources and measuring equipment you will be using throughout
More informationModel OB-ITF Infrared Through-Beam Fiber Optic Optical Barrier Operator s Manual. Version
Model OB-ITF Infrared Through-Beam Fiber Optic Optical Barrier Operator s Manual Version 11-2010 Contents 1. Introduction... 2 2. Description... 2 2.1 Model Nomenclature... 2 2.2 Operating Principle...
More informationINSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS
INSTALATION, OPERATION & MAINTENANCE MANUAL FOR PA-1001A Series SIGNAL CONDITIONER & CONVERTORS PA1001A 7/02 Page 1 of 11 SIGNAL CONDITIONER & CONVERTERS PA1001A Series INTRODUCTION: The PA1001A series
More informationModel: &
600A True RMS Digital Clamp Meter Model: 72-3097 & 72-3099 1 CONTENTS Page Number Details 3 Important Safety Information 4 Product overview 4 Key Functions 5 General Specification 5 Electrical Specification
More informationPOWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS
POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A
More informationPCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load
PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks -A Load Compact: 20 x 15 x 10 mm (L x W x H). Low power consumption: 200 mw. Flux protection or plastic-sealed construction available.
More informationElectronic Circuit Breaker with reset input ESS20-1..
Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationUsers Manual. 200W HF/50MHz Band Auto Antenna Tuner. Model HC-200AT
Users Manual 200W HF/50MHz Band Auto Antenna Tuner Model HC-200AT Caution 1. Never remove or open the tuner cover while transmitting. When there is RF in the circuits of the tuner, there will be high voltage
More informationLevel Lance Model 5100
Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection
More informationMODEL P-1400 OPERATION MANUAL Firmware Version 4.02
Reno A&E Telephone: (775) 826-2020 4655 Aircenter Circle Facsimile: (775) 826-99 Reno, Nevada 89502 Internet: www.renoae.com USA e-mail: contact@renoae.com MODEL P-400 OPERATION MANUAL Firmware Version
More informationPRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.
TRANSMISSION LINES PRELIMINARIES Generators and loads are connected together through transmission lines transporting electric power from one place to another. Transmission line must, therefore, take power
More informationIS-3000 SERIES INFRARED SCANNER
IS-3000 SERIES INFRARED SCANNER NON-CONTACT, RELIABLE, PRECISE, LONG RANGE POSITIONING FOR HOT OR COLD PRODUCTS FEATURES ANALOG AND DIGITAL OUTPUTS INDICATIVE OF TARGET POSITION, WIDTH AND TEMPERATURE
More informationDRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System
DRTS-6 Advanced Protection Relay Test Set and Measurement System MULTI-TASKING EQUIPMENT DESIGNED FOR TESTING PROTECTION RELAYS, ENERGY METERS, TRANSDUCERS POWERFUL AND LIGHTWEIGHT HIGH ACCURACY: BETTER
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 105U ISO 9001 Certified New Products... New Solutions The ELPRO 105 range of telemetry modules provide remote monitoring and control by radio or twisted-pair
More informationSureTest Model ST-1THD & ST-1THDC Instructions
#61-156 #61-157 #61-158 SureTest Model ST-1THD & ST-1THDC Instructions Introduction The SureTest family of Circuit/distortion analyzers identify problems common to electrical circuits and harmonic distortion
More informationMS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL
MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols
More informationProduct overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module
Product overview The AX-ROM135 and the AX-ROM1000 Modules enable an Analogue, Pulse or Floating point signal and convert to either a 0-135Ω or a 1KΩ Proportional Resistive output signal. The output resistance
More informationMODEL C-1000 SERIES OPERATION MANUAL
Reno A & E Telephone: (775) 826-2020 4655 Aircenter Circle Facsimile: (775) 826-99 Reno, Nevada 89502 Internet: www.renoae.com USA e-mail: contact@renoae.com MODEL C-000 SERIES OPERATION MANUAL Built-in
More informationActuators for modulating control AME 85, AME 86
Data sheet Actuators for modulating control AME 85, AME 86 Description The actuators AME 85 and AME 86 are used with VFM 2 (DN 50-250), VFS 2 (DN 65-00), VF2/3 (DN 25, 50) and AFQM (DN50-250) valves. Features:
More informationHIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES
HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE (60A type only) RELAYS A PC board type 80A Connector type 60A Screw terminal type A TM type 300A Connector type RoHS Directive compatibility
More informationUser s Manual for Integrator Short Pulse ISP16 10JUN2016
User s Manual for Integrator Short Pulse ISP16 10JUN2016 Specifications Exceeding any of the Maximum Ratings and/or failing to follow any of the Warnings and/or Operating Instructions may result in damage
More informationSRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS
ELECTRICAL ENGINEERING DIVISION Distribution Network Department SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELA T150.2 en SRA 2250/6 Resistor specification The SRA 2250/6 Resistor is intended to increase
More informationPULSE MATIC 9000 FULL DIGITAL New professional metal detector
1 PULSE MATIC 9000 FULL DIGITAL New professional metal detector IMPORTANT NOTE: The battery charger of your PULSE MATIC is 110v-240v at 12v. Consequently this battery charger can be plugged in any (AC)
More informationGROUNDING. What is it? Al Lewey K7ABL. Disclaimer
GROUNDING What is it? Al Lewey K7ABL Disclaimer Disclamier Mechanical Engineer with some electrical background My primary reference is References UP THE TOWER The Complete Guide to Tower Construction By
More informationPower Processor - Series 700F 10KVA to 150KVA
Power Processor - Series 700F 10KVA to 150KVA Power Conditioning and Regulation for Commercial & Industrial Equipment General Specifications PART 1 - GENERAL 1.1 DESCRIPTION This specification defines
More informationFlow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,
DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration
More informationMAGNETIC LOOP SYSTEMS SIMPLIFIED
MAGNETIC LOOP SYSTEMS SIMPLIFIED By Lez Morrison VK2SON Many articles have been published and made available on websites recently. Unfortunately they have tended to make construction sound complicated
More informationRIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.
User s Guide RP5600 Passive Probe July 2010 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a registered trademark
More informationFACTORY AUTOMATION. MANUAL LC10-* Laying loops for Loop detector LC10-1 and LC10-2
FACTORY AUTOMATION MANUAL LC10-* Laying loops for Loop detector LC10-1 and LC10-2 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of
More informationConstant Current Regulator INDUPERM type CCR 961
Constant Current Regulator INDUPERM type CCR 961 Standard Technical Description 961.001-GB List of content General description 2 CCR cubicle.. 4 CCR module. 5 Transformer cubicle... 10 Output Transformer..
More informationDigital Electronic Thermostat With RF
RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 1 Digital Electronic Thermostat With RF Instruction Manual Model No ALTHC015 RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 2 2 ALTHC015 INSTRUCTION
More informationApplications: Power generation, Cogeneration, Stationary power Large engines
Features: 8 inputs are user selectable from the following. 0-5V, 0-10V, 4-20 ma or 0-20 ma Digital inputs for interface to switches, etc. PWM signal, pulse or 16-bit counter inputs from sensors or diesel
More informationIC800SSD Hardware Manual Pub 348R5. for models. A publication of
IC800SSD Hardware Manual Pub 348R5 for models IC800SSD104S1A IC800SSD104RS1A IC800SSD107S1A IC800SSD107RS1A IC800SSD407RS1A IC800SSD216S1A IC800SSD216RS1A IC800SSD420RS1A IC800SSD228S1A IC800SSD228RS1A
More informationTMP-100 Turbine Meter Pulse Divider Circuit
NUFLO TM TMP-100 Turbine Meter Pulse Divider Circuit User Manual Manual No. 9A-100080245, Rev. 01 2008 Cameron International Corporation ( Cameron). All information contained in this publication is confidential
More informationNI PXI-2521 Specifications 40-Channel DPST Relay Module
NI PXI-2521 Specifications 40-Channel DPST Relay Module This document lists specifications for the NI PXI-2521 general-purpose relay module. All specifications are subject to change without notice. Visit
More informationModel FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter
Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------
More informationNI PXI-2530 Specifications
NI PXI-2530 Specifications 128-Channel Reed Relay Multiplexer/Matrix This document lists specifications for the National Instruments PXI-2530 128-channel multiplexer/matrix module. All specifications are
More informationA 75-Watt Transmitter for 3 Bands Simplified Shielding and Filtering for TVI BY DONALD H. MIX, W1TS ARRL Handbook 1953 and QST, October 1951
A 75-Watt Transmitter for 3 Bands Simplified Shielding and Filtering for TVI BY DONALD H. MIX, W1TS ARRL Handbook 1953 and QST, October 1951 The transmitter shown in the photographs is a 3-stage 75-watt
More informationLoad Cell Accessories and Services
Load Cell Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Mounting accessories Calibration services PCB Piezotronics, Inc. Toll-Free in USA 888-684-0004 716-684-0001
More informationSection 11 Electronic Position Controls & Encoders
APC-2006 All Products Catalog Section Electronic Position Controls & Encoders Force Control Industries, Inc. Main Office and Manufacturing Plant 3660 Dixie Highway Fairfield, Ohio 45014 Telephone: (513)
More informationDSP-21 Directional Counting Detector
DSP-21 Directional Counting Detector User Manual Diablo Controls, Inc. Copyright 2015 Document: DSP21_MAN_D Released: February 29, 2016 Pros Who Know Trust Diablo Table of Contents Functional Data... 5
More informationIMMS-CI-HW. Communications Controller Interface. Installation Instructions IMMS. Controller. Interface. AC From Transformer 24 VAC REM 24 VAC SEN
CI 4 Comm. IMMS-CI-HW Communications Interface POWER From Transformer Ground To REM Installation Instructions To SmartPort Sensor 1 Sensor 2 Sensor 3 From Sensors Sensor Common IMMS Interface From SI or
More informationUniversal Radius Mounting Option. Fixed Radius Mounting Option
F e a t u r e s Factory Set for Same Day Dispatch (1 to 65,536 Pulses Per Rev) 100 Degrees Centegrate cabability as standard Opto-ASIC Technology Any bore - up to 15mm bore (Metric) or (Imperial) The 60HA
More informationMODEL AF200A: FM, FM/SCA RECEIVER/MONITOR OPERATION MANUAL
MODEL AF200A: FM, FM/SCA RECEIVER/MONITOR OPERATION MANUAL THE AF200A IS AN FM AND FM/SCA PROFESSIONAL STYLE RECEIVER/ MONITOR. IT S MANY APPLICATIONS INCLUDE STATION MONITORING AND EAS MONITORING. The
More informationTECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging
TECHNICAL DATASHEET #TDAX102000 35A DC MOTOR CONTROLLER P/N: AX102000 Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging with Electronic Assistant Features: Unidirectional or bi-directional
More information