Single Channel Loop Detector
|
|
- Mark Mills
- 5 years ago
- Views:
Transcription
1 Single Channel Detector NLD-0 series The NLD0 is a single channel inductive loop detector, designed for parking and vehicle access control. The function of the detector is to detect vehicle presence by means of an inductance change caused by the vehicle passing over a wire loop buried under the road surface. Product Series: NLD-0 NLD- NLD-5 NLD-
2 NOLE OPTO Feature. Compact Size: the compact and well engineered housing combined with all the industry requirements regarding features and functionality allows this detector to be incorporated into any new or existing vehicle detection system.. Diagnostic Capabilities: Comprehensive diagnostics capabilities allow for accurate diagnosis of loop and installation problems.. Selectable Presence Time: The output of the presence relay can be selected to limit a detect output to a fixed time(time>0 minutes) while a vehicle remains on the loop.. Sensitivity setting: The sensitivity settings allow for finer adjustment of the detection level 5. Frequency setting: The frequency settings provide greater flexibility in preventing crosstalk in multi-loop applications.. Reset Switch : The reset switch enables the detector to be manually reset during commissioning and testing.this results in the detector re-tuning the sensing loop and becoming ready for vehicle detection. Two separate output relays: Presence Relay A is presence output, can be extended for 0,,5,,,5,0 or 0 seconds. Pulse Relay, programmable with external way DIP switches, provide presence, pulse on entry, pulse on exit, or failed output. Specification Self-turning range: 0-000uh Voltage: -VDC or 5-0VAC Relay output: presence relay /pulse reply Working temperature: Frequency: steps switch, 0-0KHz Response time: turn on -0MS, turn off -0NS Reset: reset by push button on front of enclosure Humidity: up to 5% relative humdiity without consideration Sensitivity: ways selectable, highest: 0.0% DL/L, Lowest:.5% DL/L wire: more than meters requires the use of a core shielded cable, do not exceed 0 meters distance between control box and loop Size: 5mm*mm*mm
3 Connections: PIN NLD-0 NLD- NLD-0 Connection NLD- Connection 0-0V AC 0-0V AC -VADC -VADC V/V 0A V/V 0A 0A Pulse Relay N.O 5 Pulse Relay COM Presence A Relay N.O Presence A Relay COM Chassis Ground 0.V 0.0V V/.mA, -mv/ /V( 以 5 密封 :.V, 开口 :.V N 5 L A.V, 密封 :.V 5 0.V 0.0V V/.mA, -mv/ /V( 以 5 A ~V 密封 :.V, 开口 :.V - + (-VADC) ~V Presence A Relay N.C 胶体 / 密封 / 开口 :.V ~V Pulse Relay N.C.V, 密封 :.V, 开口 :, 自定义 : ~V PIN NLD-5 NLD- NLD-5 Connection NLD- Connection 5 0-0V AC -VADC 0-0V AC -VADC Pulse Relay N.O Chassis Ground Presence A Relay COM Presence A Relay N.O Pulse Relay COM V/V V/V 0A 0A 0A 0.V 0.V 5 5 A 0.0V A 0.0V V/.mA, V/.mA, -mv/ /V( 以 5 -mv/ /V( 以 5 密封 :.V, 开口 :.V N L.V, 密封 :.V 密封 :.V, 开口 :.V - + (-VADC) ~V Presence A Relay N.C 胶体 / 密封 / 开口 :.V ~V Pulse Relay N.C.V, 密封 :.V, 开口 :, 自定义 : ~V
4 Connections: Faceplate LED indication: Red-Power Green-/Fault. Undetect - off. Detect - on steady. Fault - flashing Faceplate setting:. 液晶显示单元 Sencitivity. Filter. MT50 AS. Entry/Exit 5. Presence time. Delay time.frequency 远程温度传感线 RTS00RK.A 外设连接 : Switch instruction: Switch (Trimpot), Sensitivity Selection Sensitivity of the loop can be adjusted by the trimpot labeled Sensitivity. User can select different setting by turning the trimpot with 0 being the least sensitive and F being the most sensitive. Switch (Dipswitch Settings). DIP & DIP Setting Special Functions. DIP & DIP Setting Relay Output. DIP 5 Setting Automatic Reset. DIP & DIP & DIP Setting Relay A Delay 5. DIP & DIP Setting Frequency (0 K to 0 KHz). Used to avoid the interference
5 Detector position and installation:. Install the detector in a weatherproof housing.. The detector should be as close to the sensing loop as possible.. The detector should always be installed away from strong magnetic fields.. Avoid running high voltage wires near the loop detectors. 5. Do not install the detector on vibrating objects.. When the control box is installed within metres of the loop, normal wires can be used to connect the control box to the loop. More than metres requires the use of a core shielded cable. Do not exceed 0 metres distance between control box and loop.. When installation, please keep the product plug and socket in the vertical direction Switch instruction: Accessories for optional: HAR- In-kind Shooting LD-A In-kind Shooting LD- In-kind Shooting LD- In-kind Shooting Shenzhen Noble Opto Co.,Ltd Tel: 055-5/ 5
Double Channel Loop Detector
Double Channel Loop Detector NBLD-00 series The NBLD00 is a double channel inductive loop detector, designed for parking and vehicle access control. The function of the detector is to detect vehicle presence
More informationMD12-2 Metal Loop Detector
MD12-2 Metal Loop Detector Features Supply 12VDC Adjustable sensitivity (8 levels via dip switch) 2 x Relay outputs (each can be configured individually) Power up and loop activation LED indicator. Industry
More informationOperations Manual. Model NT11 & NT11-E. June 18 th 2002
Operations Manual Model NT11 & NT11-E June 18 th 2002 3609 North 44 th Street Phoenix, AZ 85018-6023 Internet: www.northstarcontrols.com Fax: (941) 426-0807 Tel: (941) 426-6396 Manual Contents Glossary
More informationInductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
More informationUSER MANUAL ULD 910. October 2003 Revision: 03. Single Channel Vehicle Detector ULD 910. Part Number: MIC
Single Channel Vehicle Detector ULD 910 USER MANUAL Part Number: MIC0302004 ULD 910 October 2003 Revision: 03 I N D E X PAGE Detector Commissioning... 1 Frequency... 1 Sensitivity... 1 Automatic Sensitivity
More informationDual Channel Traffic/Parking Detector User Guide
Dual Channel Traffic/Parking Detector User Guide Installation Manual LD-200 Rev A Dual Channel Vehicle detector LD-200 Page 1 of 4 I Connections LD-200 Dual Channels Traffic Detector User Guide Pin LD-200
More informationSingle Channel Loop Detector
Single Channel Loop Detector Model - LD113 Series The LD113 is a single channel inductive loop card detector designed for parking and access control applications. The detector is connected to an inductive
More informationSingle Channel Loop Detector
Single Channel Loop Detector Model - LD116 The LD116 is a single channel inductive loop card detector designed for parking and access control applications. The detector is connected to an inductive loop
More informationSingle Channel Loop Detector
Single Channel Loop Detector Model - LD106 Series The LD106 is an ultra low power single channel inductive loop detector designed for parking and access control applications. The LD106 can be configured
More informationDual Channel Vehicle Detector ULD 920 USER MANUAL Part Number: MIC ULD 920
Dual Channel Vehicle Detector ULD 920 USER MANUAL Part Number: MIC0302036 ULD 920 October 2003 Revision: 03 I N D E X PAGE Detector Commissioning... 1 Frequency... 1 Sensitivity... 1 Automatic Sensitivity
More informationShort form User Manual
Nortech Detection Pty Ltd Unit1, Bldg 5, Forest Central Business Park, 49 Frenchs Forest Road, Frenchs Forest NSW 2086 PO Box 6011, Frenchs Forest DC, NSW 2086 Tel: 02 8977 4047 Fax: 02 9475 4742 email:
More informationSingle Channel Loop Detector
Single Channel Loop Detector Model - LD160 Series The LD160 is a single channel inductive loop detector designed for traffic control applications. The detector is connected to an inductive loop mounted
More informationSingle Channel Loop Vehicle detector User Manual
Single Channel Loop Vehicle detector User Manual 1 Introduction CE-L02-J9 is a single channel digital inductive loop vehicle detector. It is used to identify the presence of vehicle by means of an inductive
More informationFLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR
FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR 1. Introduction The FLUX 11 is a single channel plug-in inductive loop detector designed for vehicle access applications, and interfaces
More informationWith Audible Detect Signal
T-100 SERIES SINGLE CHANNEL SHELF MOUNT DETECTOR Meets and exceeds NEMA TS 1 specification. Six front panel DIP switches provide: Seven levels of sensitivity plus off. Presence or Pulse mode. Four loop
More informationSingle Channel Loop Detector
Single Channel Loop Detector Model LD120T Series The LD120T is a series of single channel inductive loop detectors. The use of microprocessor and surface mount technology enables a large number of functions
More informationFG2 TWO-CHANNEL DETECTOR
FG TWO-CHANNEL DETECTOR. DIMENSIS AND ELECTRIC CNECTIS ENGLISH 4 VDC 4 Vdc power supply 3 4 5 6 7 8 9 0 Loop contact Loop contact Loop Loop Dimensions in mm. GENERAL INFORMATI Applications: control of
More informationUSERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS
We open up New Horizons USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS APPLICATION The MATRIX is a Digital Inductive Loop Detector used for the detection of vehicular traffic. The MATRIX is the ideal
More informationULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128
ULT-MVP ULTRALOOP O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com
More informationULT-DIN O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128
O P E R A T I N G I N S T R U C T I O N S ULT-DIN ULTRALOOP V E HI C L E L O O P DETECTOR 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com
More informationBEA s digital inductive single loop solution
BEA s digital inductive single loop solution Matrix2-S With more standard features than any other loop detector on the market, the Matrix2-S has the flexibility, compatibility and performance to maximize
More informationUSERS GUIDE MATRIX P/N SINGLE DIGITAL INDUCTIVE LOOP SENSOR
USERS GUIDE MATRIX P/N 17500001 SINGLE DIGITAL INDUCTIVE LOOP SENSOR APPLICATIONS The MATRIX Digital Inductive Loop Detector is the ideal solution for parking barrier control, motorized gates and doors,
More information601/602 Series Inductive Loop Detector
601/602 Series Inductive Loop Detector Installation Guide Sarasota Series Detectors 1 Copyright 2009 Peek Traffic Corporation Printed in the USA. All rights reserved. Information furnished by Peek is believed
More informationTECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM
TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM THIS MANUAL IS INTENDED FOR FOREMEN AND TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, OPERATION AND MAINTENANCE
More informationPD132 Loop Detector Specification
PD132 Loop Detector Specification (Version 1.00) Content 1. Application... 3 2. Technical Data... 3 3 Wiring Diagram... 3 4 Use and operational... 4 4.1 Frequency adjust... 4 4.2 Sensitivity adjust...
More informationOperating Instructions
ULT-PLG ULTRALOOP Vehicle Loop Detector Operating Instructions CAUTIONS AND WARNINGS CE REQUIREMENT: Use EMX Pre-formed loops with built-in surge suppression for CE compliance. Connect shield on lead in
More informationSPECIAL SPECIFICATION 6004 Digital Card Rack Inductive Loop Detector Assembly
2004 Specifications SPECIAL SPECIFICATION 6004 Digital Card Rack Inductive Loop Detector Assembly 1. Description. Furnish and install a digital card rack inductive loop detector assemblies. 2. Materials.
More informationAGP-0230 USER MANUAL AMANO
This document is for information only and unless otherwise indicated it is not to form part of any contract. In accordance with the manufacturer s policy of continually updating and improving design, specifications
More informationOperating Instructions
UltraDTEK Vehicle Loop Detector Operating Instructions PRODUCT OVERVIEW The UltraDTEK vehicle loop detector is plug-in compatible with Elite OmniControl TM board operators and other Elite A ELD enabled
More informationMODEL T-110 SERIES OPERATION MANUAL
Reno A & E Telephone: (775) 86-00 4655 Aircenter Circle Facsimile: (775) 86-9191 Reno, Nevada 8950 Internet: www.renoae.com USA e-mail: contact@renoae.com MODEL T-110 SERIES OPERATION MANUAL Single Channel
More informationInductive Loop Detector
Naztec Operations Manual For Inductive Loop Detector Model 722TXC TS1/TS2 April 2003 Published by: Naztec, Inc. 820 Park Two Drive Sugar Land, Texas 77478 Phone: (281) 240-7233 Fax: (281) 240-7238 Copyright
More informationPCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load
PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks -A Load Compact: 20 x 15 x 10 mm (L x W x H). Low power consumption: 200 mw. Flux protection or plastic-sealed construction available.
More informationLMD622 and LMD624 Series
LMD622 and LMD624 Series Inductive Loop Monitor THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE LMD622, LMD622T, LMD624, LMD624H, and LMD624T SERIES INDUCTIVE LOOP MONITOR. REVISION: MARCH 2012 pn 888-062X-001
More informationRME1-RME1BT INSTRUCCIONES DE INSTALACION INSTALLATIEVOORSCHRIFTEN INSTRUCTIONS D INSTALLATION ИНСТРУКЦИИ ПО УСТАНОВКЕ ISTRUZIONI DI INSTALLAZIONE
8 027908 339119 D811642_01 23-05-08 RILEVATORE DI VEICOLI A SPIRE VEHICLE LOOP DETECTOR DETECTEUR DE VÉHICULES A BOUCLE INDUCTIVE INDUKTIONSSCHLEIFEN-DETEKTOR ZUR DETEKTION VON FAHRZEUgEN DETECTOR DE VEHÍCULOS
More informationSPECIAL SPECIFICATION 1257 Digital Card Rack Non-Invasive Micro Loop Detector Assembly (8 Slot Rack)
1993 Specifications CSJ 0924-06-147, etc. SPECIAL SPECIFICATION 1257 Digital Card Rack Non-Invasive Micro Loop Detector Assembly (8 Slot Rack) 1. Description. This Item shall govern for furnishing, and
More informationInstallation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY
CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CLASS MODEL SERIAL HP Installation Manual Use this manual for circuit
More informationMODEL L-1200 SERIES OPERATION MANUAL
Reno A & E Telephone: (775) 826-2020 4655 Aircenter Circle Facsimile: (775) 826-99 Reno, Nevada 89502 Internet: www.renoae.com USA e-mail: contact@renoae.com MODEL L-200 SERIES OPERATION MANUAL Built-in
More informationBULLETIN # B
Page 1 of 9 BULLETIN # B-18-2002 From: Parts and Service Division Date: February 14, 2002 To: All Authorized Service Agencies SUBJECT: Convection Oven Controller Troubleshooting MODELS AFFECTED: All Garland
More informationDigital Electronic Thermostat With RF
RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 1 Digital Electronic Thermostat With RF Instruction Manual Model No ALTHC015 RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 2 2 ALTHC015 INSTRUCTION
More informationSMARTSCAN INFORMATION
SMARTSCAN INFORMATION SS SLC NOV05 SLC2 and SLC4 SAFETY INDUCTIVE LOOP CONTROLLERS INSTALLATION GUIDE Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954,
More informationPCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US
PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique
More informationNI PXI-2530 Specifications
NI PXI-2530 Specifications 128-Channel Reed Relay Multiplexer/Matrix This document lists specifications for the National Instruments PXI-2530 128-channel multiplexer/matrix module. All specifications are
More informationPhoto-electric Amplifier ISG-A123 1-channel automatic amplifier
Photo-electric Amplifier -channel automatic amplifier Amplifier with modulated infrared light Range up to 25 m (82 ft) Automatic Level Control (ALC) according to assembly distance and direction Test function
More informationDSP-10 Vehicle Detector
User Manual DSP-10 Vehicle Detector Diablo Controls, Inc. Copyright 2014 Document: DSP10_MAN_B Released: August 31, 2015 Pros Who Know Trust Diablo 1. Contents Figures... 3 2. Introduction... 4 3. Technical
More informationTECHNICAL DATASHEET #TDAX CAN SAE J1939, Dual Output Valve Controller
TECHNICAL DATASHEET #TDAX020200 CAN SAE J1939, Dual Output Valve Controller Features: Two independent, software controlled outputs selectable as: Proportional Current (up to 2.5A); Hotshot Digital; PWM
More informationFour Channel Inductive Loop Detector
Naztec Operations Manual For Four Channel Inductive Loop Detector Model 724/224 April 2003 Published by: Naztec, Inc. 820 Park Two Drive Sugar Land, Texas 77478 Phone: (281) 240-7233 Fax: (281) 240-7238
More informationMODEL AF200A: FM, FM/SCA RECEIVER/MONITOR OPERATION MANUAL
MODEL AF200A: FM, FM/SCA RECEIVER/MONITOR OPERATION MANUAL THE AF200A IS AN FM AND FM/SCA PROFESSIONAL STYLE RECEIVER/ MONITOR. IT S MANY APPLICATIONS INCLUDE STATION MONITORING AND EAS MONITORING. The
More informationMATRIX INDUCTIVE LOOP CONTROL BOX
EN MATRIX INDUCTIVE LOOP CTROL BOX MATRIX-S2-24: single loop with 2 to 24 V AC/DC power supply MATRIX-D2-24: double loop with 2 to 24 V AC/DC power supply MATRIX-S220: single loop with 220 to 240 V AC
More informationNI PXI-2521 Specifications 40-Channel DPST Relay Module
NI PXI-2521 Specifications 40-Channel DPST Relay Module This document lists specifications for the NI PXI-2521 general-purpose relay module. All specifications are subject to change without notice. Visit
More informationELSEMA 1-Channel 433MHz Receiver with 16A Relay Output- GLR
GLR43301240 1-Channel 433MHz Gigalink, Receiver with Mains AC Supply Features Supply voltage 240VAC (also available in 110-120VAC supply for international markets) High efficiency toroidal transformer
More informationUSi Product Presentation. Mayser Ultrasonic Industrial Sensor USi
USi Product Presentation Mayser Ultrasonic Industrial Sensor USi Page 1 Contents Ultrasonic Technology - General technology - Mayser Ultrasonic Technology Ultrasonic Industrial Sensor - Intended use -
More informationRatchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj
Ratchet Relay Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation at each pulse input
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 105U ISO 9001 Certified New Products... New Solutions The ELPRO 105 range of telemetry modules provide remote monitoring and control by radio or twisted-pair
More informationA local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.
FEATURES - Extends wiring distance of FTT-10 LonWorks Networks. - Up to 5 repeaters can be daisy chained together to create a multi-segment repeater of up to 10 channels. - Low cost alternative to routers
More informationMINI-SA2. User Manual. Technical Characteristics. Mounting. Version 1.1 MINI-SA2
User Manual These low profile standalone proximity readers are able to read EM4002 type card / fobs and have capacity up to 4000 users. All electronics are self contained within the reader, therefore no
More informationMODEL P-1400 OPERATION MANUAL. Four Loop Inputs, Two Vital Outputs, and One Vital Input
Reno A & E 4655 Aircenter Circle Reno, NV 89502-5948 USA Telephone: (775) 826-2020 Facsimile: (775) 826-99 Website: www.renoae.com E-mail: contact@renoae.com MODEL P-400 OPERATION MANUAL Four Loop Inputs,
More informationINTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:
Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:
More informationNI PXI-2520 Specifications 80-Channel SPST Relay Module
NI PXI-2520 Specifications 80-Channel SPST Relay Module This document lists specifications for the NI PXI-2520 general-purpose relay module. All specifications are subject to change without notice. Visit
More informationRADIO REMOTE SYSTEMS
Section / Description page 4-FUNCTIONS PTM RADIO TRANSMITTER... RC4 6-FUNCTIONS PTM RADIO TRANSMITTER... RC5 4/6-FUNCTIONS METER-IN SHW RADIO TRANSMITTER... RC6 CANBUS RADIO RECEIVER... RC7 APPLICATION
More informationPhotoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs
Photoelectrics, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs µ-processor controlled unit for up to 10 sets of photoelectric sensors Up to 10 independent outputs Self-diagnostic
More informationPROMUX Distributed MODBUS I/O Modules Catalog and Design Guide
PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 12/03/2012 V11.0 P.O.Box 164 Seven Hills 1730 NSW AUSTRALIA Tel: +61 2 96248376 Fax: +61 2 9620 8709 Email: proconel@proconel.com Web: www.proconel.com
More informationPD230 Enhanced Vehicle Detector USER MANUAL
Nortech International (Pty) Ltd PO Box 4099 32A Wiganthorpe Road Willowton Hub Pietermaritzburg Pietermaritzburg 3201 South Africa 3200 South Africa Reg. No. 98/1095 Tel: (033) 345 3456 Int. Tel: +27 33
More informationTECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection
Quick Start Guide TECO F510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information
More informationXARS8D18p / XARS12D18p / XARS8L12p Quick Start Guide
Quick Start Guide Harmony www.schneiderelectric.com www.schneiderelectric.com/control TM XARS8D18W / XARS8D18H / XARS12D18W / XARS12D18H exlhoist XARS8L12W / XARS8L12H DANGER HAZARD OF ELECTRIC SHOCK,
More informationSection 11 Electronic Position Controls & Encoders
APC-2006 All Products Catalog Section Electronic Position Controls & Encoders Force Control Industries, Inc. Main Office and Manufacturing Plant 3660 Dixie Highway Fairfield, Ohio 45014 Telephone: (513)
More informationModel FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter
Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------
More informationFMR Description
1-Channel 151MHz FM Receiver with mains AC supply Features Supply voltage 240VAC (also available in 110-120VAC supply for international markets) High efficiency toroidal transformer High capacity output
More informationMODEL P-1400 OPERATION MANUAL Firmware Version 4.02
Reno A&E Telephone: (775) 826-2020 4655 Aircenter Circle Facsimile: (775) 826-99 Reno, Nevada 89502 Internet: www.renoae.com USA e-mail: contact@renoae.com MODEL P-400 OPERATION MANUAL Firmware Version
More informationDSP-21 Directional Counting Detector
DSP-21 Directional Counting Detector User Manual Diablo Controls, Inc. Copyright 2015 Document: DSP21_MAN_D Released: February 29, 2016 Pros Who Know Trust Diablo Table of Contents Functional Data... 5
More informationFMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15108 (No Case version)
FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15108 (No Case version) 1, 2, 4, 8-Channel 151MHz Transmitter Features Long range up to 5km. 100mW Transmitter with current consumption
More informationSTANDARD WIRING DIAGRAMS FOR SMART MODEL 20
SMART SERIES CODING SYSTEM FOR AV ACTUATOR WIRING DIAGRAMS There are 3 elements to the wiring codes used in AVA electric actuators: WIRING CODE 1 3 Wire system, single pole double throw, switching the
More informationSF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications
Long Range Wireless Applications 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) The SF900C Series Remote Control/Switch Followers are a twoway system designed to
More informationPowerFlex 400 AC Drive Guide Specification
PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives 3.0 50HP @ 200 to 240V AC 3.0 350HP @ 380 to 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum
More informationNI PXI/PXIe-2532 Specifications
NI PXI/PXIe-2532 Specifications 512-Crosspoint, 1-Wire Matrix This document lists specifications for the NI PXI/PXIe-2532 (NI 2532) 512-crosspoint matrix. All specifications are subject to change without
More informationCOD GB / 1.0 RBAND/UMS - RBAND/CSM
INTRODUCTION DESCRIPTION The RadioBand system is designed of Industrial, Commercial and Domestic door and gate applications where a safety edge is used. The system provides a wireless system replacing
More informationIC800SSD Hardware Manual Pub 348R5. for models. A publication of
IC800SSD Hardware Manual Pub 348R5 for models IC800SSD104S1A IC800SSD104RS1A IC800SSD107S1A IC800SSD107RS1A IC800SSD407RS1A IC800SSD216S1A IC800SSD216RS1A IC800SSD420RS1A IC800SSD228S1A IC800SSD228RS1A
More informationPowerPlex Compact Module PP-C-COM24
Description The PowerPlex Compact Module has been designed for the 12 V or 24 V DC-System of special vehicles, buses or boats. It provides inputs for switches and sensors as well as power outputs with
More informationSTANDARD WIRING DIAGRAMS FOR SMART MODEL 20
CODING SYSTEM FOR AV ACTUATOR WIRING DIAGRAMS There are 3 elements to the wiring codes used in AVA electric actuators: WIRING CODE 1 3 Wire system, single pole double throw, switching the live SPDT 2 3
More informationDSP-20 Dual Channel Vehicle Detector With Directional Logic
User Manual DSP-20 Dual Channel Vehicle Detector With Directional Logic Diablo Controls, Inc. Copyright 2014 Document: DSP20_MAN_B Released: May 31, 2016 Pros Who Know Trust Diablo 1. Contents 2. Introduction...3
More informationNI PXI/PXIe-2529 Specifications
NI PXI/PXIe-2529 Specifications 128-Crosspoint Relay Matrix This document lists specifications for the NI PXI/PXIe-2529 (NI 2529) matrix module. All specifications are subject to change without notice.
More informationTMP-100 Turbine Meter Pulse Divider Circuit
NUFLO TM TMP-100 Turbine Meter Pulse Divider Circuit User Manual Manual No. 9A-100080245, Rev. 01 2008 Cameron International Corporation ( Cameron). All information contained in this publication is confidential
More informationFMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15101, FMT15102, FMT15104, FMT15108 (No Case version)
FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15101, FMT15102, FMT15104, FMT15108 1, 2, 4, 8-Channel 151MHz Transmitter Features Long range up to 5km. 100mW Transmitter with current
More informationTECHNICAL PRODUCT DATASHEET
FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR OEM DISTRIBUTION ONLY TECHNICAL PRODUCT DATASHEET High Density PDM 21 Output / 10
More informationMPR kHz Reader
MPR-5005 Page 1 Doc# 041326 MPR-5005 125kHz Reader Installation & Operation Manual - 041326 MPR-5005 Page 2 Doc# 041326 COPYRIGHT ACKNOWLEDGEMENTS The contents of this document are the property of Applied
More informationIS-3000 SERIES INFRARED SCANNER
IS-3000 SERIES INFRARED SCANNER NON-CONTACT, RELIABLE, PRECISE, LONG RANGE POSITIONING FOR HOT OR COLD PRODUCTS FEATURES ANALOG AND DIGITAL OUTPUTS INDICATIVE OF TARGET POSITION, WIDTH AND TEMPERATURE
More informationAnalog Servo Drive 25A20DD
Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit
More informationMODEL C-1000 SERIES OPERATION MANUAL
Reno A & E Telephone: (775) 826-2020 4655 Aircenter Circle Facsimile: (775) 826-99 Reno, Nevada 89502 Internet: www.renoae.com USA e-mail: contact@renoae.com MODEL C-000 SERIES OPERATION MANUAL Built-in
More informationTransmitters & Receivers
Transmitters & Receivers Contents 4 Channel Multi-Function Receiver / Transmitter Set - 433.92 MHz with Onboard Relays RXPROR4...2 4 Channel Universal Wireless Receiver ALE-4RX...3 2 Channel Transmitter
More informationMK372/Ultrasonic Sensor System. Installation & Setting up Instructions. Comprising. MK372 Indicator/Controller Ultrasonic Transmitter
MK372/Ultrasonic Sensor System Installation & Setting up Instructions Comprising MK372 Indicator/Controller Ultrasonic Transmitter 1 Contents page Page 1.0 Overview 3 2.0 General Specification MK372 4
More informationMFJ ENTERPRISES, INC.
Screwdriver Antenna Controller Model MFJ-1926 INSTRUCTION MANUAL CAUTION: Read All Instructions Before Operating Equipment! MFJ ENTERPRISES, INC. 300 Industrial Park Road Starkville, MS 39759 USA Tel:
More informationAbsolute encoders - SSI
with through hollow shaft Features Encoder multiturn / SSI Optical sensing method Resolution: singleturn 14 bit, multiturn 12 bit Compact design Cost-efficient mounting High reliability by self-diagnostics
More informationActuators for modulating control AME 85, AME 86
Data sheet Actuators for modulating control AME 85, AME 86 Description The actuators AME 85 and AME 86 are used with VFM 2 (DN 50-250), VFS 2 (DN 65-00), VF2/3 (DN 25, 50) and AFQM (DN50-250) valves. Features:
More informationTEST REPORT CONCERNING THE COMPLIANCE OF AN INDUCTIVE LOOP VEHICLE DETECTOR, BRAND NORTECH, MODEL PD231 AND PD234 WITH 47 CFR PART
Testing and certification of, consultancy and research concerning, electronic and electric appliances, systems, installations and telecommunication systems TEST REPORT CONCERNING THE COMPLIANCE OF AN INDUCTIVE
More informationNetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00
NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www
More informationNo mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.
Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital
More informationCAME QP- V4.4 SPECIFICATION STANDARDS CABLE PLAN CABLE TYPES Z SERIES AUDIOCODE CONTROL SET FOR DOUBLE LEAF GATES
Z SERIES Technical Document AUDIOCODE CONTROL SET FOR DOUBLE LEAF GATES QP- V4.4 CAME V4.4 Rev 1.0 2/2005 STANDARDS SPECIFICATION The V4 audiocode control set is for double leaf swing gates using CAME
More informationUser s Manual for Integrator Short Pulse ISP16 10JUN2016
User s Manual for Integrator Short Pulse ISP16 10JUN2016 Specifications Exceeding any of the Maximum Ratings and/or failing to follow any of the Warnings and/or Operating Instructions may result in damage
More informationECM3 EARTH CONTINUITY RELAY
TECHNICAL DATASHEET ECM3 EARTH CONTINUITY RELAY Electrical Protection for Hard Rock Mines Application The ECM3 has been designed to provide earth continuity protection for cables containing pilot cores.
More informationFACTORY AUTOMATION. MANUAL LC10-* Laying loops for Loop detector LC10-1 and LC10-2
FACTORY AUTOMATION MANUAL LC10-* Laying loops for Loop detector LC10-1 and LC10-2 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of
More informationIF30. User's manual. Description. Table of contents IF30
User's manual IF30 Description IF30 is an encoder interface unit designed to convert the output signals delivered by so-called sine-cosine-encoders and similar measuring systems (devices which deliver
More information