1 ADTECH Solar inverter 1. Product description Thank you very much for your selection of special solar inverter launched by ADTECH (SHENZHEN) TECHNOLOGY CO., LTD. Solar energy special inverter is designed by our company which is suitable for use in the field of solar photovoltaic conversion governor after years of exploration and research in the field of solar photovoltaic. According to the characteristics of the working principle of solar pv panels and the power supply, this product has the following features: MPPT is Maximum Power Point Tracking (hereinafter referred to as the Maximum Power Point Tracking), The MPPT controller can real-time detect power voltage of solar panels and track the highest voltage current value (VI), make the system with the highest efficiency for battery charging. Solar energy converter plays an important role in the photovoltaic system, coordinating the efforts of solar panels, battery load, is an indispensable component in pv systems. Software unique MPPT algorithm through the controller can real-time detect solar panels power voltage to adjust output frequency, fast dynamic response, make the motor work consistently in the maximum power point, so that the solar photovoltaic panels to maximum economic efficiency Software increase the function of keyboard encoder resolution Settings, a variety of resolution to choose from, and easy to use; Inverter main power input can use solar pv dc power supply, can also be a single-phase, three-phase ac power supply, simple wiring, truly achieve the power supply mode, expand the frequency inverter application scope; Wide voltage design, make the inverter can remain stable under high and low voltage work, strong adaptability.

2 2. Model Description

3 3. Technical Specification Frequency Inverter Model Rated Capacity (KVA) Rated Output Current (A) Adapter Motor Power (KW) 2S S S T T T T T T T T T T T T T T T T T T Main Circuit and Control Terminals Diagram 4.1 Main Circuit Terminals Description Main Circuit Terminals Diagram: take example for G type without special required I. Type I main circuit terminals adapt to the following model: 2S0007~2S0022, 2T0007~2T0015 4T0007~4T0040

4 II. Type II main circuit terminals adapt to the following model: 4T0055~4T0075, 2T0022~ 2T0040 III. Type III main circuit terminals adapt to the following model: 4T0110~4T0150, 2T0055~2T0075 IV. Type IV main circuit terminals adapt to the following model: 4T0185~4T0220, 2T0110~2T0150 V. Type V main circuit terminals adapt to the following model: 4T0300~4T03704

5 5. Main circuit terminals function description: Terminal label R S T U V W Functional specifications ac power input terminals, three-phase 380 v ac power Inverter output terminal, connect a three-phase ac motor Dc reactor terminals, end to P1, the P1 P+ other end of the P + P+ P- Dc power supply or brake unit External braking resistor P+ DB terminals, P + end, on the other side G Earthing terminal and the earth 6. Control Terminal Description Control circuit terminal layout is shown below Figure 4-1 control circuit terminal layout able 4-1 frequency converter control terminal function Type Terminal symbol Terminal +10V-GND External + 10V power supply Power supply Add the + 24V 24V-CM power Function Description Outward provide + 10V power supply, the maximum output current: 10mA - Generally used as the power supply external potentiometer, potentiometer resistance range Wai: 1kΩ ~ 5kΩ Provided outside the + 24V power is generally used as digital inputs and outputs Child work, power supply and the external sensor. Maximum output power

6 Flow: 200mA The factory default connected with + 24V, V External power input When using an external signal when driving X1 ~ X5, V needs an external power source Terminals Connected and disconnected with the + 24V power terminal AI1-GND Analog Input Terminal 1 1, the input voltage range: DC 0V ~ 10V 2. Input impedance: 22kΩ 1. the input range: DC 0V ~ 10V / 4mA ~ Analog income AI2-GND Analog Input Terminal 2 20mA, the control System board jumpers J8 selection decisions. 2.When voltage input input 22kΩ, current:, input impedance 500Ω. Digital input X1- V Digital input 1 X2- V Digital input 2 X3- V Digital input 3 X4- V Digital input 4 High-speed pulse input Terminals X5- V 1, the optical coupling isolation, compatible with bipolar input 2. Input impedance: 2.4kΩ 3. when the level of the input voltage range: 9V ~ 30V Apart from X1 ~ X4 features, but also as high-speed pulse input Aisle. Maximum input frequency: 100kHz Analog Output AO1-GND Analog output 1 J5 jumper from the control panel to select the voltage or current output decision Out. Output voltage range: 0V ~ 10V Output current range: 0mA ~ 20mA

7 Digital Output DO1-CE Digital input 1 Optical coupling isolation, dual polarity open collector output Output voltage range: 0V ~ 24V Output current range: 0mA ~ 50mA Away, but the factory CE and CM have external shorting (in this case DO1 The default is + 24V drive). When DO1 want to use an external power supply drive, You must disconnect the external short circuit CE and the CM. By function code F5-00 "FM terminal output to FM- CM High-speed pulse output select" Selected When a high-speed pulse output, the maximum frequency to 100kHz; When used as an open collector output, with the same specifications DO1. Normally closed Contact driving ability: Relay output A- B terminal 25Vac,3A,COSØ=0.4 30Vdc,1A A- C Normally open terminal Auxiliar Function expansion 28 pin connector, and an optional card (I / O y card expansion card, PLC cards, each J12 Interface Optional bus cards and other kinds of card) Interfac interface e J3 PG card interface Alternatively: OC, differential, UVW, resolver interfaces J7 External Keyboard Interface External keypad 7. The parameter setting Set FP-00 non-zero value, which sets the parameters of password protection at the function parameter mode and the user changes the parameter mode, the Senate Need to enter the number of the menu in the correct password, remove password, you need to set FP Parameters menu customization parameters mode is not password protected. F group, A

8 group is a basic function parameters, U group is to monitorfunction parameters. 8. Monitoring Parameters table Function code Name smallest unit communication address U0 set of basic monitoring parameters U0-00 Operating frequency (Hz) 0.01Hz 7000H U0-01 Set frequency (Hz) 0.01Hz 7001H U0-02 Bus voltage (V) 0.1V 7002H U0-03 Output voltage (V) 1V 7003H U0-04 Output Current (A) 0.01A 7004H U0-05 Output power (kw) 0.1kW 7005H U0-06 Output torque (%) 0.1% 7006H U0-07 X terminal input status H U0-08 DO terminal output status H U0-15 PID set 1 700FH U0-16 PID feedback H U0-25 The current power-on time 1Min 7019H U0-26 Current run time 0.1Min 701AH U0-28 Communication setting 0.01% 701CH U0-29 Encoder feedback speed 0.01Hz 701DH U0-45 Fault information 1 702DH U0-58 Z signal counter 1 703AH U0-59 Set frequency (%) 0.01% 703BH U0-60 Operating frequency (%) 0.01% 703CH U0-61 Inverter status 1 703DH U0-62 Current fault coding 1 703EH Menu symbols as follows: " ": set the value of the parameter indicates the drive is in stop and run state, can be changed; " ": indicates the set value of the parameter when the drive is running, can not be changed; "*": Indicates that the parameter is "Factory Parameters", only by the manufacturer that prevents the user for action; " ": indicates the value of the parameter is the actually measured value can not be changed. Table 5-2 basic function parameters profile

9 Function code Name Description of the setting range The factory Change limit setting F0 Basic Function Group F0-01 Control mode 0: Speed sensorless vector control (SVC) 0 selection 1: speed sensor vector control (FVC) 2: V / F control F0-02 Run command 0: Operation panel command channel (LED off) 1: Terminal command channel (LED 0 mode selection lights) 2: Communication command channel (LED flashes) F0-03 A primary frequency reference selection 0: Digital setting + UP / DOWN(preset frequency F0-08power down without memory) 1: Digital setting + UP / DOWN (preset frequency F0-08, down memory) 2: Terminal Analog AI1 3: Terminal Analog AI2 4: Extended terminal Analog AI3 0 5: X5 terminal pulse 6: Multi-speed command 7: Simple PLC 8:PID 9: Enter the MPPT F0-08 Preset Frequency 0.00Hz ~ maximum frequency (F0-10) 50.00Hz F0-10 Maximum 50.00Hz~320.00Hz 50.00Hz frequency F0-12 Upper limit Lower frequency F0-14 ~ Maximum 50.00Hz frequency frequency F0-10 F0-13 The upper limit 0.00Hz ~ maximum frequency F H frequency offset F0-14 Lower frequency 0.00Hz ~ upper limit frequency F Hz F0-15 Carrier frequency 0.5kHz~16.0kHz Model deterninati on F0-16 Carrier frequency temperature 0:N 1:Y 1 modulation F0-17 Acceleration time s~650.00s(F0-19=2) 0.0s~6500.0s(F0-19=1) 0s~65000s(F0-19=0) Model determinati on

10 F0-18 Deceleration time 1 F0-19 Deceleration time increments F0-22 Frequency command resolution 0.00s~650.00s(F0-19=2) 0.0s~6500.0s(F0-19=1) 0s~65000s(F0-19=0) 0:1 Second 1:0.1 Second 2:0.01 Second 1:0.1Hz 2:0.01Hz Model determinati on 1 2 F1 Motor Parameters F1-00 Motor type selectio 0:Common asynchronous motor 1:Variable frequency asynchronous motor 2:Permanent magnetic synchronous motor 0 F1-01 Rated motor power 0.1kW~1000.0kW Model Dependent F1-02 Rated motor voltage 1V~2000V Model Dependent F1-03 Rated motor 0.01A ~ A ( AC driver current power<=55kw) 0.1A ~ A ( AC driver power >55kW) F1-04 Rated motor 0.01Hz~Max frequency frequency F1-05 Rated motor 1rpm~65535rpm rotational speed F1-06 Stator resistance 0.001Ω ~ Ω (AC driver power (asynchronous <=55kW) motor) Ω ~ Ω (AC driver power <=55kW) F1-07 Rotor resistance 0.001Ω ~ Ω (AC driver power (asynchronous <=55kW) motor) Ω ~ Ω (AC driver power <=55kW) F1-08 Leakage inductive 0.01mH ~ mH ( AC driver power reactance <=55kW) (asynchronous 0.001mH~65.535mH (AC driver power motor) <=55kW) F1-09 Mutual inductive 0.1mH ~ mH ( AC driver power reactance <=55kW) (asynchronous 0.01mH ~ mH ( AC driver motor) power >55kW) Model Dependent Model Dependent Model Dependen Coordinati ng parameter s Coordinati ng parameter s Coordinati ng parameter s Coordinati ng parameter s

11 F1-10 No-load current 0.01A~F1-03(AC driver power<=55kw) Coordinati (asynchronous 0.1A~F1-03(AC driver power >55kW) ng motor) parameter s 0:No auto-tuning 1:Asynchronous motor static auto-tuning F1-37 Auto-tuning 2 : Asynchronous motor complete 0 selection auto-tuning 3:Static integrity parameter identification 11 : Synchronous motor with-load auto-tuning 12 : Synchronous motor no-load auto-tuning F4-00 X1 Function selection F4-01 X2 Function selection F4-02 X3 Function selection F4-03 X4 Function selection F4 Group Input Terminal 0:No function 1:Forward RUN (FW) or running order 2:Reverse RUN(REV) or positive and negative direction (Notice:When set up 1 2,need match F4-11 to use, details functions according to the parameter instruction ) 3:Three-line control 4:Forward JOG(FJOG) 5:Reveres JOG(RJOG) 6:Terminal UP 7:Terminal DOWN 8:Coast to stop 9: Fault reset(reset) 10:RUN pause 19:UP/DOWN setting reset(terminal, operation panel) 20:Control command switch terminals 1 21:Acceleration/Deceleration prohibited \ 22:PID pause 29:Torque control prohibited 30:X5 pulse frequency input 31:Retain 32:Immediate DC braking 33:Normally closed(nc) input of external fault 34:Frequency Change Enable 35:Reverse PID action direction

12 F4-04 X5 Function selection 36: External STOP terminal 1 37:Command source switch terminal 2 38:PID integral pause 50:Clear the current running time 51 : Switchover between two-line mode and three-line mode 52-59:Retain F4-10 X Filter time 0.000s~1.000s 0.010s 0:Two-line mode 1 F4-11 Terminal command 1: Two-line mode 2 mode 2:Three-line mode 1 0 3:Three-line mode 2 F4-12 Terminal UP/DOWN 0.001Hz/s~65.535Hz/s 1.00Hz/ rate s F4-13 AI Curve 1 Minimum 0.00V~F V Input F4-14 AI curve 1 minimum %~+100.0% 0.0% input Set the corresponding F4-15 AI Curve 1 Max input F4-13~+10.00V 10.00V F7-01 FK-function selection F7 group Keyboard and Display Invalid 0:FK 1: Control Panel command channel and remote commands Channel (command Terminal command chann el or communications through Road) switch 2: reversing switch 3: the turning point 4: turning points 0 F7-02 STOP/RESET function 0: only in the keyboard mode, STOP/RES Key stop function effectively 1: in any operating mode, STOP/RES Key stop function are effective 1 F7-06 Load coefficient of sp eed is displayed F7-07 Inverter module radiat or temperaturedegre es ~ ~

13 F7-08 Temporary software version NO. F7-09 Total running time 0h~65535h --- F7-10 Products No F7-11 Software version No F7-13 Total power on time 0~65535 hour --- F7-14 Total power consumption time 0~65535 degree --- F9-00 F9 fault and protection Motor overload protection 0: Reject 1: Allow 1 F9-01 Motor overload protection the gain 0.20~ F9-02 Motor overload early warning factors 50%~100% 80% F9-03 Overvoltage stalling g ain 0~100 0 F9-04 Stall protection 120%~150% 130% F9-05 Loss of velocity gain 0~ F9-06 Loss of speed protectio 100%~200% 150% Electric short circuit F9-07 protection is selected 0:Invalid on 1:valid 1 Optional F9-09 Automatic fault reset number 0~20 0 Automatic fault reset F9-10 during With disabilities DO 0: No action 0 action selection 1:action F9-11 F9-12 Automatic fault reset interval Input lack of \ contact pull-in protection choices 0.1s~100.0s 1.0s Single digits: input phase failure protection choices Ten: contactor closing

14 protection 0: Allow 1:Reject F9-14 First fault types 0: no failure 1: reserved 2: accelerating the overcurrent 3: deceleration overcurrent 4: constant current 5: accelerating voltage 6: deceleration voltage 7: constant voltage 8: a buffer overload resistance 9: under pressure 10: inverter overload 11: motor overload 12: enter the phase 13: output phase 14: module from overheating 15: External fault 16: communication exception 17: contactor exception 18: the current exception 19: abnormal motor tuning 20: encoder/pg card exception 21: the exception parameter reading and writing 22: Converter hardware exceptions 23: motor short circuit to ground 24: reservation 25: reservations 26: run time 27: user-defined fault 1 28: user-defined fault 2

15 29: power-on time of arrival 30: set out 41: switch motor running 43: motor speed 45: motor overtemp F9-15 Second fault types Third fault types(the F9-16 lastest time) FP function code management FP-00 User password 0~ : no action 01: restore factory settings, excluding motor parameters FP-01 Number Initial parameter 02: to clear the log information 0 04: backup the user's current parameters 501: restoring backup parameters Notes: 1. The simple manual come from general-purpose inverter, is suitable for solar ene rgy special frequency converter, If you want to know more function, please refer to user manual of general-purpose inverter. 2. Aim at loading characteristic of solar energy special frequency converter, some o f common parameters were set before shipment, no need set again. 3. If you need the inverter output frequency change automatically according to the input voltage change, please put F0-03 into Inverter used the wrong power supply level or output of the motor and the inverter output voltage is not consistent may cause frequency converter or motor damage, please select corresponding specifications inverter according to the motor power and power specifications. 5. Modify F1 motor parameters set F1-05 won t affect the real output rotate speed of inverter. 6. Modify F1 motor parameters set F1-05 will affect actual output voltage of converter, 380VAC level inverter by modifying the parameters can output voltage 220VAC, but 220VAC level inverter by modifying the parameters cannot output voltage 380VAC.Please try to keep the factory default values, connect to the corresponding class motor to achieve maximum efficiency. 7. When carrier frequency is less than 3KHz, the largest distance between the inverter and motor should be within 50 M. When carrier frequency is more than 4 KHZ, should be

16 appropriate to reduce the distance, this connection is best to be equipped in the metal tube. If necessary, need add output reactor or filter. 8. Others matters needing attention according to random general inverter user manual. 6. Application Case Solar water supply control system is supplied DC power for the inverter by photovoltaic panels, inverter will drag pump and pump water of wells into the bucket. Both inside of wells and bucket have one water level gauge, when water in wells is lower than the minimum water level inverter will stop, when the water in bucket is higher than the upper limit water level inverter also will stop. Parameter setting Function Code Functional Setting Description F0-02 Terminal instructions 1 control operation F0-03 MPPT set operating 9 frequency F0-17 Acceleration time 25S F0-18 Deceleration time 25S F4-00 X1 Forward running 1 F4-01 Free stop 8 F9-09 Malfunction automatic reset times 10

YL6000 Frequency Converter

YL6000 Frequency Converter HUAJIANG YL6000 Frequency Converter Table Manual Note 1. Before using YL600 products, User Manual must be carefully read and be kept properly for future reference after being read. 2. User Manual should

More information

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection Quick Start Guide TECO F510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information

More information

Operating Instructions

Operating Instructions 4XH35QB151210 Small General Frequency Converter Operating Instructions 220V 0.75KW 5.5KW 400V 0.75KW 15KW Please read the instruction carefully and understand the contents so that it can be installed and

More information

Contents. Safety Information and Precautions Product Information Operation Panel (Keypad & Display) Quick Setup...

Contents. Safety Information and Precautions Product Information Operation Panel (Keypad & Display) Quick Setup... Contents Safety Information and Precautions...2 1. Product Information...4 1.1 Nameplate and Designation Rule... 4 1.2 General Specifications... 5 1.3 Environment... 9 2 Wiring... 10 2.1 Typical System

More information

MD310 Quick Start Manual. General-Purpose AC Drive

MD310 Quick Start Manual. General-Purpose AC Drive MD310 Quick Start Manual General-Purpose AC Drive ersion 0.1 Dated 14 th OCT, 2013 CONTENTS CHAPTER 1 PRODUCT INFORMATION... 1 1.1 Designation... 1 1.2 Nameplate... 1 1.3 General Specifications... 2 CHAPTER

More information

DORNA TECHNOLOGY CO., LTD. DLA1 Series Inverter. User Manual (V1.0)

DORNA TECHNOLOGY CO., LTD. DLA1 Series Inverter. User Manual (V1.0) DORNA TECHNOLOGY CO., LTD DLA1 Series Inverter User Manual (V1.0) Table of Contents 1 Summary... 4 1.1 Name plate... 4 1.2 Product series... 5 1.3 Technical standards... 6 1.4 Peripheral Electrical Devices

More information

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13 Index A A Group functions 3 9 AC reactors 5 3 Acceleration 1 15, 3 8 characteristic curves 3 26 second function 3 24 two-stage 4 19 Acceleration stop function 3 21 Access levels 3 5, 3 36, 4 25 Access

More information

Preface. Notes. Thank you for purchasing the VTP8 series AC drive.

Preface. Notes. Thank you for purchasing the VTP8 series AC drive. Preface Thank you for purchasing the VTP8 series AC drive. The VTP8 series AC drive is a general-purpose high-performance current vector control AC drive. It can implement the control of asynchronous motor.

More information

HV580L Series Frequency Inverter User Manual

HV580L Series Frequency Inverter User Manual User Manual HNC Electric Limited Contents Contents... 2 Chapter 1 Safety Information and Precautions... 4 1.1 Safety Information... 4 1.2 General Precautions... 7 Chapter 2 Product Information... 10 2.1

More information

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE 1 2 SERIES 1 2 pag. 4 pag. 5 Applications Model identification 3 pag. 5 4 pag. 6 Capacity

More information

HV580 Series Frequency Inverter User Manual

HV580 Series Frequency Inverter User Manual User Manual HNC Electric Limited Contents Contents...2 Chapter 1 Safety Information and Precautions...4 1.1 Safety Information... 4 1.2 General Precautions...7 Chapter 2 Product Information...10 2.1 Designation

More information

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class HITACHI SJ1 Series Inverter Quick Reference Guide Single-phase Input 2V Class Three-phase Input 2V Class Three-phase Input 4V Class Hitachi Industrial Equipment Systems Co., Ltd. Manual No. NB5821XD Dec.

More information

TOSVERT TM VF-nC3 Parameter List

TOSVERT TM VF-nC3 Parameter List TOSVERT TM VF-nC Parameter List E658664 - Setting information * Please fill it in if necessary. Item Content Item Content Setting date / person Customer Application Application model Motor manufacturer

More information

CHAPTER 8 PARAMETER SUMMARY

CHAPTER 8 PARAMETER SUMMARY CHAPTER PARAMETER SUMMARY Group 0: System Parameter VFD-V Series 00-00 Identity Code Based on the model type 00-01 Rated Current Display 00-02 Parameter Reset 00-03 00-04 Star-up Display of the Drive Definitions

More information

6.9 Jump frequency - Avoiding frequency resonance

6.9 Jump frequency - Avoiding frequency resonance E581595.9 Jump frequency - Avoiding frequency resonance : Jump frequency : Jumping width Function Resonance due to the natural frequency of the mechanical system can be avoided by jumping the resonant

More information

S11 Adjustable Speed Drive Engineering Specification

S11 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba S11 AC Variable Frequency Drives, 6 pulse for 3- phase 200-240VAC, 380-500VAC and single phase 200V to 240VAC. 1.1 References A. National

More information

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class HITACHI L1-M Series Inverter Quick Reference Guide Single-phase Input 1V Class Hitachi Industrial Equipment Systems Co., Ltd. Manual No. NB5741XD December 23 Caution: Be sure to read the L1 Inverter Manual

More information

NICE900 -Door Drive Setup Manual for Asynchronous / Synchronous Motor with Encoder Feedback (Document Release Dt ) Sr. No

NICE900 -Door Drive Setup Manual for Asynchronous / Synchronous Motor with Encoder Feedback (Document Release Dt ) Sr. No Inova Automation Pvt Ltd., NIBHI Corporate Centre, 3 rd Floor, No.7, CBI Colony, 1 st Main Link Road, Perungudi, Chennai-600096. Ph:-+91 (0)44 4380 0201 Email:- info.inovaindia@inova-automation.com Website:-

More information

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC Simple, scalable and economical Service Bosch Rexroth

More information

VF-nC1 Adjustable Speed Drive Engineering Specification

VF-nC1 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba VF-nC1 AC Variable Frequency Drives, 6 pulse for 100V single-phase 0.1 to 0.75kW, 200V single-phase 0.2 to 2.2kW and 200V threephase 0.1

More information

ADJUSTABLE SPEED DRIVES. AS1 Drive

ADJUSTABLE SPEED DRIVES. AS1 Drive ADJUSTABLE SPEED DRIVES AS1 Drive Toshiba s New ASD Product Line The AS1 drive builds on Toshiba s history of supplying powerful, reliable, and versatile drives. We have combined our best drive features

More information

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 10

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 10 The Drive & Control Company Frequency Converter VFC 3610 / VFC 5610 Series Quick Start Guide R912005518 Edition 10 Bosch Rexroth AG VFC 3610 / VFC 5610 Record of Revision Edition Release Date Notes DOK-RCON04-VFC-X610***-QU01-EN-P

More information

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS CHAPTER 8 SUMMARY OF PARAMETER SETTINGS VFD-S Series!: The parameter can be set during operation, *: Twice the value for 460V class. Group 0 User Parameters Parameters Explanation s 0-00 Identity Code

More information

NX series Constant and variable torque Variable Speed Drives for induction motors

NX series Constant and variable torque Variable Speed Drives for induction motors Honeywell All in One Application Manual NX series Constant and variable torque Variable Speed Drives for induction motors Subject to changes without notice CONTENTS NX "All in One" APPLICATION MANUAL INDEX

More information

Multi-function, Compact Inverters. 3G3MV Series

Multi-function, Compact Inverters. 3G3MV Series Multi-function, Compact Inverters 3G3MV Series There has been a great demand for inverters with more functions and easier motor control than conventional i OMRON's powerful, compact 3G3MV Series with versat

More information

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

CHAPTER AC DRIVE PARAMETERS. In This Chapter... CHAPTER AC DRIVE 4 PARAMETERS In This Chapter... GS2 Parameter Summary....................4 2 Detailed Parameter Listings.................4 11 Motor Parameters........................4 11 Ramp Parameters.........................4

More information

GS1 Parameter Summary Detailed Parameter Listings...4 9

GS1 Parameter Summary Detailed Parameter Listings...4 9 CHAPTER AC DRIVE 4 PARAMETERS Contents of this Chapter... GS1 Parameter Summary...............................4 2 Detailed Parameter Listings..............................4 9 Motor Parameters.........................................4

More information

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS CHAPTER DESCRIPTION OF PARAMETER SETTINGS.1 Group 0: User Parameters 0-00 Identity Code of AC Drive Factory setting: d# Settings None V HP 1/4 1/2 1 2 3 11V/230V d0 d2 d4 d6 d8 460V -- -- -- d3 d d7 d9

More information

Before you operate the inverter, the parameters that you must first program are the basic parameters.

Before you operate the inverter, the parameters that you must first program are the basic parameters. . Main parameters Before you operate the inverter, the parameters that you must first program are the basic parameters..1 Searching for changes using the history function () : History function History

More information

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual Hitachi P1 Closed Loop Hoist Basic Instruc on Manual DH Firmware V.18 DETROIT HOIST AND CRANE LLC, CO. 6650 STERLING DRIVE NORTH STERLING HEIGHTS MICHIGAN 48312 Introduction This manual only applies to

More information

Operation Manual. KVF660 Series Open Loop Vector Inverter SHENZHEN KEWO ELEETRIE CO., LTD.

Operation Manual. KVF660 Series Open Loop Vector Inverter SHENZHEN KEWO ELEETRIE CO., LTD. Operation Manual KVF660 Series Open Loop Vector Inverter SHENZHEN KEWO ELEETRIE CO., LTD. Content Content Content Safety precautions... 1 1. General... 2 1.1 General technical specifications... 2 1.2 of

More information

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps. VFD - D700 Series Specifications The latest low-cost variable speed control solution for centrifugal pumps. Built-in PID Control to maintain pressure, flow, measured value, and much more 125% overload

More information

Preface IMPORTANT NOTES PV series Solar Pumping Inverter

Preface IMPORTANT NOTES PV series Solar Pumping Inverter Preface PV200 special inverters are developed for power supply of water pumps, based on the core control arithmetic of FR200 vector control inverters, combined with the control requirements of PV water

More information

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL D SERIES LM16 COMPACT DRIVE V/f and SLV CONTROL LM16 COMPACT DRIVE V/f and SLV CONTROL 1 2 SERIES 1 2 page 4 page 6 Introduction Fields of application 3 page 7 4 page 8 Designation Product offer 5 6 page

More information

General Specifications FECA-TE /2010. Phone: Fax: Web:

General Specifications FECA-TE /2010. Phone: Fax: Web: General Specifications FECA-TE-117 06/2010 1. Standard Specifications 1) Three-phase 230V series Output ratings Input ratings Braking Item Specifications Type (FRN C1S-2U) F12 F25 F50 001 002 003 005 Nominal

More information

CONTENTS CONTENTS...1 SAFETY PRECAUTIONS INTRODUCTION...4

CONTENTS CONTENTS...1 SAFETY PRECAUTIONS INTRODUCTION...4 CONTENTS CONTENTS...1 SAFETY PRECAUTIONS...3 1. INTRODUCTION...4 1.1 Technology Features...4 1.2 of Plate...5 1.3 Selection Guide...5 1.4 Parts...7 1.5 External Dimension...8 2. INSPECTION...11 3. INSTALLATION...12

More information

EMHEATER. EM9 Series Frequency Inverter. User s Manual. China EM Technology Limited. EM9 Series Inverter User s Manual. Address:

EMHEATER. EM9 Series Frequency Inverter. User s Manual. China EM Technology Limited. EM9 Series Inverter User s Manual. Address: EM9 Series Inverter User s Manual User s Manual EMHEATER EM9 Series Frequency Inverter China EM Technology Limited Address: No.80, Baomin 2 road, Xixiang, Bao'an District,Shenzhen,China Phone: 86-0755-29985851

More information

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R INVERTER ROLL TO ROLL FUNCTION MANUAL FR-A820-00046(0.4K)-04750(90K)-R2R FR-A840-00023(0.4K)-06830(280K)-R2R FR-A842-07700(315K)-12120(500K)-R2R Roll to Roll Function The FR-A800-R2R inverter has dedicated

More information

NZV Series Sensorless Vector Control Inverter Operation Manual

NZV Series Sensorless Vector Control Inverter Operation Manual NZV Series Sensorless Vector Control Inverter Operation Manual Thank you very much for your buying NZV series sensorless vector control inverter. Before use, please read this manual thoroughly to ensure

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide The Invertek Optidrive E3 Frequency Inverter range is available to order from inverterdrive.com This guide is intended to complement

More information

Product description. At a glance. Customer benefits

Product description. At a glance. Customer benefits Product description New series is a general current vector control inverter integrated with the performance and features in a high degree. with industry-leading drive performance and functionality control,

More information

C.TY TNHH TỰ ĐỘNG HÓA VIỆT TRUNG Preface

C.TY TNHH TỰ ĐỘNG HÓA VIỆT TRUNG Preface Preface Thanks for using the MD300A series inverter presented by Inovance Technology Co., Ltd.. Developed on the basis of extensive market research, MD300A series inverter is a general-purpose inverter

More information

vacon nx all in one application manual ac drives Phone: Fax: Web: -

vacon nx all in one application manual ac drives Phone: Fax: Web:  - vacon nx ac drives all in one application manual vacon 1 INDEX Document ID:DPD00903A Revision release date: 30.3.2012 1. Basic Application...5 1.1. Introduction...5 1.1.1. Motor protection functions in

More information

Contents. Safety Information and Precautions Product Information Wiring Operating Panel (Keypad & Display)...

Contents. Safety Information and Precautions Product Information Wiring Operating Panel (Keypad & Display)... Contents Safety Information and Precautions...2 1. Product Information...3 1.1 Nameplate and Designation Rule... 3 1.2 General Specifications... 4 2 Wiring...6 2.1 Terminal Description... 6 2.2 Terminals

More information

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives Page 2 (68) Index Honeywell HVAC Application (Software [ALFIQ105] Ver.2.09) INDEX 1. INTRODUCTION... 3 2. CONTROL I/O... 3. HVAC APPLICATION

More information

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD. RYKO Manufacturing Company 116 N.W. 54th Ave. P.O.Box 38 Grimes, Iowa 5111 Phone (515) 986-37 www.ryko.com Fax (515) 986-3621 sales@ ryko.com INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+

More information

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

AV-300i Specifications. Saftronics Inc.  PC10 Product Specifications PC10. Mini Vector AC Drive Saftronics Inc. www.saftronics.com TM AV-300i Specifications PC10 Product Specifications PC10 Mini Vector AC Drive 1 (1) T hree-phas e 230V input Drive Hp 1/8 1/4 1/2 1 2 3 5 7.5 10 Nominal applicable

More information

VFS11 Parameter List for up to CPU version 105

VFS11 Parameter List for up to CPU version 105 E65824 VFS Parameter List for up to CPU version 5 Setting Date Customer End user Application Application No/Serial No Inverter s Type-Form Quantity Inverter s Serial No Motor s capacity If user s value

More information

HPVFP High Performance Full Function Vector Frequency Inverter

HPVFP High Performance Full Function Vector Frequency Inverter Advanced User Manual HPVFP High Performance Full Function Vector Frequency Inverter HP VER 1.00 1. HPVFP Parameter Set Overview...3 1.1. About this section...3 1.2. Parameter Structure Overview...3 1.3.

More information

Manual Overview...1 2

Manual Overview...1 2 GETTING STARTED CHAPTER 1 Contents of this Chapter... Manual Overview.....................................1 2 Overview of this Publication..................................1 2 Who Should Read This Manual...............................1

More information

USER MANUAL Version: 1.1

USER MANUAL Version: 1.1 AE-LIFT MOTOR DRIVER USER MANUAL Version: 1.1 Index SECTION 1-WARNINGS...1 SECTION 2-TECHNICAL SPECIFICATIONS...2 2.1 ELECTRICAL SPECIFICATIONS...2 2.2 MECHANICAL SPECIFICATIONS...3 SECTION 3-TECHNICAL

More information

vacon 100 flow ac drives application manual

vacon 100 flow ac drives application manual vacon 100 flow ac drives application manual vacon 1 TABLE OF CONTENTS Document: DPD01083A Version release date: 16.11.12 Corresponds to software package FW0159V121106.vcx 1. Vacon 100 FLOW - Quick Startup

More information

Dual-inverter Wire Drawing Machine CHV130 series Frequency inverter Operation manual

Dual-inverter Wire Drawing Machine CHV130 series Frequency inverter Operation manual Dual-inverter Wire Drawing Machine CHV130 series Frequency inverter Operation manual Notice: Please use this manual together with CHV Series Close Loop Vector Control Inverter Operation manual. SHENZHEN

More information

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

AV-300i Specifications. Saftronics Inc.   VG10 Product Specifications VG10. Dynamic Vector Drive Saftronics Inc. www.saftronics.com TM AV-300i Specifications VG10 Product Specifications VG10 Dynamic Vector Drive 1 Category Item Description Nominal Motor 230 VAC, 3 Phase 1/4 Hp to 125 Hp 460 VAC, 3

More information

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6 CHAPTER KEYPAD OPERATION 3 AND QUICKSTART In This Chapter... The GS2 Digital Keypad.....................3 2 LED Display.........................................3 2 LED Indicators.......................................3

More information

FUJI Inverter. Standard Specifications

FUJI Inverter. Standard Specifications FUJI Inverter o Standard Specifications Norminal applied motor The rated output of a general-purpose motor, stated in kw. That is used as a standard motor. Rated capacity The rating of an output capacity,

More information

Content. GT series inverter CONTENTS

Content. GT series inverter CONTENTS Content CONTENTS SAFETY PRECAUTIONS... 2 1. INTRODUCTION... 3 1.1 Technical Features... 3 1.2 Description of Name plate... 4 1.3 Selection Guide...... 4 1.4 Parts Description... 5 2. UNPACKING INSPECTION...

More information

Goodrive inverter for air compressor. Preface

Goodrive inverter for air compressor. Preface Goodrive 300-01 Series Inver ter for Air Compressor GD300-01-037G-4 Preface Preface Goodrive300-01 series inverter for air compressor is developed based on Goodrive300 hardware platform and can be widely

More information

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 15

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 15 The Drive & Control Company Frequency Converter VFC 3610 / VFC 5610 Series Quick Start Guide R912005518 Edition 15 Bosch Rexroth AG VFC 3610 / VFC 5610 Record of Revision Edition Release Date Notes DOK-RCON04-VFC-X610***-QU06-EN-P

More information

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual INDEX A AC Drive Cover: 1 6 Dimensions: 2 4 External Parts and Labels: 1 6 Heat Sink Fins: 1 6 Input Mode Switch (Sink/Source): 1 6 Introduction to DuraPulse GS3 AC drive: 1 3 Keypad: 1 6 Model Number

More information

EMHEATER R. User Manaul. EM12-SP Series Solar Inverter. China EM Technology Limited V1.0. China EM Technology Limited

EMHEATER R. User Manaul. EM12-SP Series Solar Inverter. China EM Technology Limited V1.0. China EM Technology Limited EMHEATER R User Manaul EM12-SP Series Solar Inverter EMHEATER R China EM Technology Limited Address: No.8, Baomin 2 road, Xixiang, Bao'an District,Shenzhen,China Phone: 86-755-29985851 Fax: 86-755-299735

More information

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS CHAPTER DESCRIPTION OF PARAMETER SETTINGS.1 Group 0: System Parameter VFD-V Series 00-00 Identity Code Factory setting Read Only Settings Based on the model type 00-01 Rated Current Display Factory setting

More information

Fan and Pump AC Inverter

Fan and Pump AC Inverter Fan and Pump AC Inverter Key Features for Fan and Pump Applications PID and Auto Energy Saving Functions. Input Phase Loss and Output Phase Loss Protection. LCD Keypad can be used to copy parameter settings

More information

[ 4 ] Using pulse train input (F01 = 12)

[ 4 ] Using pulse train input (F01 = 12) [ 4 ] Using pulse train input (F01 = 12) Selecting the pulse train input format (d59) A pulse train in the format selected by the function code d59 can give a frequency command to the inverter. Three types

More information

Single-phase or three phase AC220V (-15% ~ +10%) 50 ~ 60Hz

Single-phase or three phase AC220V (-15% ~ +10%) 50 ~ 60Hz KT270-H Servo Drive Features: The use of DSP ( digital signal processor ) chip, greatly accelerating the speed of data acquisition and processing, the motor running with good performance. Application of

More information

EV100 Series Vector Frequency Inverter. Contents

EV100 Series Vector Frequency Inverter. Contents Contents Contents CONTENTS... 1 SAFETY PRECAUTIONS... - 3-1 OVERVIEW... 4 1.1 COMPREHENSIVE TECHNICAL CHARACTERISTICS OF FREQUENCY INVERTER...4 1.2 INSTRUCTIONS ON NAMEPLATE OF FREQUENCY INVERTER...5 1.3

More information

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Variable Frequency Drive / Inverter (0.4 ~ 280kW) Variable Frequency Drive / Inverter (0.4 ~ 280kW) & Standard Features Configuration Comparison Comparison Table Enclosure IP00 IP20 NEMA 1 Rating Single phase 0.4 2.2kW 0.4 1.5kW Three phase 0.4 4kW Constant

More information

VFS9 Parameter List for Version110 or later

VFS9 Parameter List for Version110 or later VFS9 Parameter List for Version110 or later Setting Date Customer End user Application Application /Serial Inverter s Type-Form Quantity Inverter s Serial Motor s capacity If user s value is same as shipping

More information

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866) DF5-... Frequency Inverters 1 st published 22, edition 02/02 Moeller GmbH, 53105 Bonn Author: Holger Friedrich Editor: Michael Kämper Translator: Dominik Kreuzer All brand and product names are trademarks

More information

CHV Series Close loop Vector Control Inverter Operation Manual

CHV Series Close loop Vector Control Inverter Operation Manual CHV Series Close loop Vector Control Inverter Operation Manual Thank you very much for your buying CHV series close loop vector control inverter. Before use, please read this manual thoroughly to ensure

More information

CHE Series Sensorless Vector Control Inverter Operation Manual

CHE Series Sensorless Vector Control Inverter Operation Manual CHE Series Sensorless Vector Control Inverter Operation Manual Thank you very much for your buying CHE series sensorless vector control inverter. Before use, please read this manual thoroughly to ensure

More information

V&T Technologies Co., Ltd. Vectorque TM V6-H-M1 SERIES INVERTER ADDITIVE MANUAL (M1) V6-H Series ADDITIVE MANUAL V& T

V&T Technologies Co., Ltd.   Vectorque TM V6-H-M1 SERIES INVERTER ADDITIVE MANUAL (M1) V6-H Series ADDITIVE MANUAL V& T Vectorque TM V6-H-M1 SERIES INVERTER ADDITIVE MANUAL (M1) V6-H Series ADDITIVE MANUAL V& T Change Scope Increase control function of vector control 2 with encoder speed feedback to support machine tool

More information

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

FREQUENCY INVERTER VFR-013 QUICK START GUIDE FREQUENCY INVERTER VFR-013 QUICK START GUIDE Inoréa Automation & Industry 9 rue du Lugan 33130 BEGLES www.inorea.com Table of contents 1. PEOPLE SAFETY... 3 2. MATERIAL SAFETY... 3 3. NAME PLATE... 4 a.

More information

E3 Adjustable Speed Drive Engineering Specification

E3 Adjustable Speed Drive Engineering Specification E3 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba E3 AC Variable Frequency Drives, 6 pulse for 230V and 460V. 1.1 References A. National

More information

vacon nx ac drives all in one application manual

vacon nx ac drives all in one application manual vacon nx ac drives all in one application manual PREFACE VACON 3 PREFACE Document ID: DPD00903F Date: 14.8.2017 Software code: Basic Application = ASFIFF01 Standard Application = ASFIFF02 Local/Remote

More information

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB DF5-... Frequency Inverters 1 st published 22, edition 02/02 Moeller GmbH, 53105 Bonn Author: Holger Friedrich Editor: Michael Kämper Translator: Dominik Kreuzer All brand and product names are trademarks

More information

13. Before making a service call Trip information and remedies

13. Before making a service call Trip information and remedies . Before making a service call Trip information and remedies.1 Trip causes/warnings and remedies When a problem arises, diagnose it in accordance with the following table. If it is found that replacement

More information

MEGA Servo setup procedure for driving PMS motor

MEGA Servo setup procedure for driving PMS motor Application Note AN-MEGA-0016-v105EN MEGA Servo setup procedure for driving PMS motor Inverter type FRENIC MEGA (-EAQ Type) Software version 1700 Required options OPC-G1-PG, OPC-G1-PG2, OPC-G1-PG22, OPC-G1-PMPG

More information

This operation manual is intended for users with basic knowledge of electricity and electric devices.

This operation manual is intended for users with basic knowledge of electricity and electric devices. This operation manual is intended for users with basic knowledge of electricity and electric devices. Safety Information Safety Information Read and follow all safety instructions in this manual precisely

More information

Compact & Powerful Inverter STARVERT ig5a 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts

Compact & Powerful Inverter STARVERT ig5a 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts Compact & Powerful Inverter STARVERT ig5a 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts Inverter STARVERT ig5a LS Starvert ig5a is very competitive in its price

More information

8000B Series Enhanced Inverter User Manual

8000B Series Enhanced Inverter User Manual Enhanced Inverter User Manual Version code:8000b-e201208-1mb TABLE OF CONTENTS Notes for Safe Operation... 01 Notes for Other Important Operations... 06 Chapter 1 Select the Right Type... 08 1.1 Description

More information

Safety Precautions. Description of safety marks: Use. Goods Arrival Inspection. Installation

Safety Precautions. Description of safety marks: Use. Goods Arrival Inspection. Installation Preface Thank you very much for buying AD200 series inverter. The AD200 series inverter is a kind of high-performance vector control inverter. The product adopts speed sensorless vector control technology,

More information

High-performance Vector-type SF-G Series Inverter

High-performance Vector-type SF-G Series Inverter SF-G Series 5.5-160KW Quality and Innovation Industrial Upgrading High-performance ector-type SF-G Series Inverter Superior Performance just for your ISO 14001 BSMI ISO 9001 BSMI 認可登錄 REGISTERED CERT.

More information

vacon nxp arfiff30 user manual generator application ac drives

vacon nxp arfiff30 user manual generator application ac drives vacon nxp ac drives arfiff30 generator application user manual vacon 1 Vacon Generator application INDEX Document code: DPD01916A Software code: ARFIFF30V073 Date: 15.11.2016 VACON GENERATOR APPLICATION...

More information

CHF Series Universal Inverter Operation Manual

CHF Series Universal Inverter Operation Manual CHF Series Universal Inverter Operation Manual Thank you very much for your buying CHF series universal inverter. Before use, please read this manual thoroughly to ensure proper usage. Keep this manual

More information

ig5a 0.4~1.5kW (0.5~2HP) 1phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 380~480Volts Compact & Powerful Drive

ig5a 0.4~1.5kW (0.5~2HP) 1phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 380~480Volts Compact & Powerful Drive Compact & Powerful Drive iga ~1.kW (0.~2HP) 1phase 200~230Volts ~22kW (0.~30HP) 3Phase 200~230Volts ~22kW (0.~30HP) 3Phase 380~480Volts Drive Starvert iga LS Starvert iga is very competitive in its price

More information

FST610 series high performance universal inverter. Preface

FST610 series high performance universal inverter. Preface Preface Thank you for selecting FST-610 series frequency inverter from Shenzhen Anyhertz Drive Co., Ltd. The FST-610 Drive is a series of high performance general frequency inverter with three kinds of

More information

DeviceCraft Revision #1 11/29/2010

DeviceCraft Revision #1 11/29/2010 DeviceCraft Revision #1 11/29/2010 DC Wiper Motor H-Bridge Servo / Speed Controller P/N 1020 Features: Dip Switch selectable mode of operation Both PID servo or speed controller Forward/Reverse operation

More information

AF-300 G11 Specifications. GE Industrial Systems. Product Specifications AF-300 G11

AF-300 G11 Specifications. GE Industrial Systems. Product Specifications AF-300 G11 apple GE Industrial Systems Product Specifications AF-300 G11 TM 1 Category Item Description Nominal Motor 230 VAC, 3 Phase 1/4 Hp to 125 Hp 460 VAC, 3 Phase 1/2 Hp to 450 Hp Braking Torque (Standard)

More information

Frequency Inverters. SJ700B Series. Powerful Inverter for General Purpose Use. SJ700B Series

Frequency Inverters. SJ700B Series. Powerful Inverter for General Purpose Use. SJ700B Series Frequency Inverters Frequency Inverters High performance, powerful functions, user friendly. A powerful drive with high starting torque and easy configuration Improved Sensorless Vector Control and Auto

More information

AF91 Adjustable Frequency Drives Series B

AF91 Adjustable Frequency Drives Series B Effective: January, 00 Page New Information AF9 Adjustable Model AF9 Description Model AF9 Adjustable Frequency AC Drives are designed to provide adjustable speed control of -phase motors. These microprocessor-based

More information

ig5a Compact AC Drive 0.4~1.5kW(0.5~2HP) 1-phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 380~480Volts

ig5a Compact AC Drive 0.4~1.5kW(0.5~2HP) 1-phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 380~480Volts iga Compact AC Drive ~1.kW(0.~2HP) 1-phase 200~230Volts ~22kW(0.~30HP) 3-Phase 200~230Volts ~22kW(0.~30HP) 3-Phase 380~480Volts Drive STARVERT iga LS Starvert iga is very competitive in its price and shows

More information

FEATURES DESCRIPTION THE OEM ADVANTAGE

FEATURES DESCRIPTION THE OEM ADVANTAGE FEATURES PMAC2 controller from Delta-Tau controls amp bridge directly MODEL POWER I-CONT (A) I-PEAK (A) 7229AC 32~132VAC 10 20 7429AC 32~264VAC 10 20 Serial digital current feedback from U & V phases Mini

More information

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control. Section 16680 VARIABLE SPEED DRIVE SYSTEMS OR AFD Part I - GENERAL I.01 Description A. This specification is to cover a complete adjustable frequency motor drive consisting of a pulse width modulated (PWM)

More information

In the event of a failure, the inverter switches off and a fault code appears on the display.

In the event of a failure, the inverter switches off and a fault code appears on the display. Issue 03/05 Faults and Alarms 5 Faults and Alarms 5.1 Fault messages In the event of a failure, the inverter switches off and a fault code appears on the display. NOTE To reset the fault code, one of three

More information

The Drive & Control Company. Frequency Converter. EFC 3610 / EFC 5610 Series. Quick Start Guide R Edition 12

The Drive & Control Company. Frequency Converter. EFC 3610 / EFC 5610 Series. Quick Start Guide R Edition 12 The Drive & Control Company Frequency Converter Series Quick Start Guide R912005856 Edition 12 Record of Revision Edition Release Date Notes DOK-RCON03-EFC-X610***-QU03-EN-P 2015.01 Added new functions

More information

vacon 100 flow ac drives application manual

vacon 100 flow ac drives application manual vacon 100 flow ac drives application manual PREFACE VACON 3 PREFACE Document ID: DPD01083D Date: 15.10.2014 Software version: FW0159V010 ABOUT THIS MANUAL This manual is copyright of Vacon Plc. All Rights

More information

9. RS485 Communication

9. RS485 Communication 9. RS485 The communication between inverter and external controller is doing by RS485 using modular connector in cling to inverter controller. Function Initial Minimum Maximum code Value Unit Description

More information

Shenzhen Alpha Inverter Co., Ltd. AS100 AC Servo Drive

Shenzhen Alpha Inverter Co., Ltd. AS100 AC Servo Drive Shenzhen Alpha Inverter Co., Ltd. AS100 AC Servo Drive 1 Feature AS100 series AC servo system consists of the all-digital AC servo drive and the permanent-magnet servo motor. AS100 AC servo drive adopts

More information