1 PS0A AC Bench Power Supply PS0A Bench power supply capable of direct line or 2 to 0 VAC variable output. Fused output at 0 A for line and 5 A for variable output. Includes voltage and current displays and external monitor outputs. Disclaimer: This document, associated technical descriptions and design information comprise a W5BWC Electronics project done exclusively for John L. Keith W5BWC. This is an original work of W5BWC Electronics intended to function properly and be accurately presented as described herein; however, no part of this project is offered for sale, presented to be free of patent infringements, or represented to be fit for any particular use. Any public use of this information is offered for educational purposes only, as a description of a personal project. Any and all liability of its' use is the sole responsibility of the user. Copyright 2009 by W5BWC Electronics PS0A90 Rev A
2 Applications PS0A AC Bench Power Supply Intended for bench testing AC powered equipment. Variable transformer allows voltage to equipment under test to be brought up slowly. Excellent for testing input voltage range over which equipment operates correctly. True RMS current meter dedicated to measuring output current. With external BNC monitors, the shape of nonrms current can be measured. External monitors are phased correlated for power factor calculations. Features Selection of straight line voltage or variable 2 to 0 VAC output. Voltage monitored with high Voltage rectifier and averaged for RMS display. External BNC monitors for voltage and current. All modes fused with front panel fuses. Front panel NEMA 55R receptacle Current monitored with true RMS converter for up to 5: crest factor. Characteristics Parameter Conditions Value Notes Input Voltage 60 Hz 20 VAC Input Current 20 VAC line voltage 0 A maximum 2 Output Voltage 0 to 5 A load current 2 to 0 VAC 0 to 0 A load current Input line voltage Output Current Variable Voltage Selected 0 to 5 A, Line Voltage Selected 0 to 0 A Output Voltage Display ½ Digits Type HiVoltage Rectifier averaged for RMS Accuracy ±0.5%,5 Monitor Point, 50 ± 2%, M Output Current Display ½ Digits Type Accuracy Monitor Point, 50 True RMS Detector ± 2% (.5 to 0 Amps) ± 0 ma (0 to.5 Amps) ± 2% (.5 to 0 Amps) ± 0 ma (0 to.5 Amps) 2
3 Calibration First, calibrate the Voltage Display. Set the output voltage to 20.0 VAC using an accurate external meter and adjust the calibrate potentiometer on Assy PS0A02. Use Caution while performing this step as the adjustment is near T2 s slider ring that exposes the output voltage. Second, calibrate the Voltage Monitor Point using an accurate meter connected to BNC connector J2. Adjust R8 on the PS0A0 printed circuit board assembly for 2.00 VAC with the Output voltage adjusted to 20.0 VAC. Output Voltage is adjusted to 2 VAC. Connect a load to the output that consumes 600 to 200 Watts at nominal line voltage. Use either an accurate clampon or series connected Ampmeter capable of 0 Amps. Adjust the Output voltage to obtain 2.00 Amp load current. Adjust the calibrate potentiometer on U2 for a display of Connect an accurate AC Voltmeter to BNC J and adjust R7 on the PS0A0 assembly for Volts AC. Third, calibrate the Current Display. Ensure the Output Voltage switch, S2 is in the Variable position and the Operation Warning: This line operated AC power supply has internal connections that expose Voltages capable of severe or lethal shock. In this age of low Voltage miniature electronics, do not forget to use Caution while working inside this unit. Normal operation, with the unit enclosed, should pose no risk to the user, other than the fact its output can be lethal if exposed by external connections. The Power Switch, S, applies and removes power to the entire unit including the output connector, J. The Output Voltage selector switch, S2, selects either straight line Voltage or variable Voltage. The Output Voltage adjustment is accomplished by the variac, T2, which has approximate Voltage settings on the front panel. The Output is connected to the equipment under test by way of J, a NEMA 55R panel mounted receptacle. Poweron indicator, I, will light when S is on. If F is blown or removed it will not light. I is not effected by F2, the Variable Output fuse. Output Voltage and current are independently monitored by U and U2. The Voltage display is an averaged high Voltage rectifier while the current display is a true RMS reading for peak to RMS ratios under 5. This feature is included to improve the current measurement accuracy for poor power factor loads such as rectifier or SCR equipment. Phase correlated Monitor Points are included for both Voltage and current. Using an oscilloscope, peak amplitudes and phase alignment can be determined. Theory of operation The primary use for the PS0A is to provide either line or variable AC power to equipment under test. Incoming power is protected by F, a 0A AG panel mounted fuse and controlled by on/off switch, S. Output selection is done by S2 for fixed line or variable AC output. Variac, T2, provides an adjustable Voltage from 0 to 20 VAC (or nominal line Voltage), which is boosted by T to 2 to 0 VAC. Note, for low line Voltage the full 0 VAC may not be available under full load conditions. The variable output is protected by F2. Output Voltage is displayed on U. D20 and R20 form a high Voltage rectifier with a ms charge time constant. R202 and R20 isolate the DPM from the AC line and along with R20 and R205 scales the nominal 69 VDC rectifier output to VDC for U, resulting in a displayed reading of R205 calibrates the display only. T provides isolation from the AC output for the monitor at J2. R8 is used to calibrate the Monitor Point output. Output current is displayed on U2. U02 is an RMS to DC converter which along with C05 and C06 provides a DC voltage that is equivalent to the AC Voltage at it s input.
4 Transformers T and T are orthogonally mounted to minimize magnetic coupling. C08 removes a residual MHz from the relatively low level at J s output. This provides a cleaner appearance for scope monitoring. The MHz artifact is from the DC to DC conversion process in U0 and U0. are LCD DPM that cannot monitor their own supply Voltage source. Power to operate U0 and U0 as well as the remaining circuitry is provided by T0 and the 5.6 and 5.6 VDC zener regulated power supply. These microcurrent power supplies are required to provide isolated operating power to U and U2 which T T2 T T0 T ASSY PS0A0 F2 T S2 U VOLTS DISPLAY CAL MON CURRENT CAL T PS0A02 T U2 MON VOLTS CAL CURRENT DISPLAY CAL Figure. Top view, looking down into steel enclosure. Front panel is at the bottom and the variac, T2, is in the center and assembly PS0A0 is to the right. Figure 2. Top view of chassis removed from the steel enclosure. Note locations of key components and calibration points. R6 U0 T0 D0 R0 C0 C0 R02 C02 D0 C0 U0 R0 R R06 U02 R0 R08 R07 U0 R R2 C06 C05 R7 R8 J CAL E08 E5 E E0 E06 E07 ASSY PS0A0 PWB PS0A20 Figure. Component locator for assembly PS0A0.
5 5.6V 5.6V 7 VAC 60 HZ 5.6V 5.6V PS0A AC BENCH POWER SUPPLY 2 TO 0 0 TO 5 A RMS LINE 0 A RMS JL KEITH REV A W5BWC ELECTRONICS 20.0 IN U0 OUT R6 PWR U PS90A 20K DPM 2 (NOTE 7) E (NOTE 6) P E2 F LINE 0A OUTPUT VOLTAGE (A.C. VOLTS) S POWER ON DP IN E0 E R5 00K R 887K T 2 5 A T2 OUTPUT VOLTAGE I V POWER VARIABLE F2 5A R K C07.0 POLY LINE (0A) VARIABLE (5A).2 20 VAC RMS S2 OUTPUT W D07 N5 J OUTPUT 5.6V 8 U0 LF5 5.6V 2 R 6.9K T 7.77: E VAC RMS R2 K 5. 2O VAC RMS R09 2.7K CW R8 K (NOTE 5) E09 R0 0K NOTES: UNLESS OTHERWISE SPECIFIED, ALL VALUES IN OHMS, uf AND uh. COMPONENT DESIGNATORS BELOW 00 ARE CHASSIS MOUNTED. COMPONENT DESIGNATORS ABOVE 00 ARE MOUNTED ON ASSY PS0A0 (PWB PS0A20). R7 ADJUSTED TO CAL OUTPUT CURRENT AT J. R8 ADJUSTED TO CAL OUTPUT VOLTAGE AT J2. OUTPUT VOLTAGE CONTAINS A 0.02%/AMP ERROR. DPM CAL IS USED FOR FINAL DISPLAY CAL. U0 AND U0 PROVIDE DC ISOLATION FOR DPM POWER. T AND T ORTHOGONALLY MOUNTED J2 OUTPUT VOLTAGE X 0. (INTO M OHM) C0 22 6V C0 22 6V 5.6V 5.6V 2 D05 N 522B D06 N 522B R0 80 R02 80 U0 IN OUT PS90A (NOTE 7) C0 00 6V C V D0 N00 D02 N00 D0 N00 D0 N00 E0 R0 20K E02 PWR T0 VAC 0.A OUTPUT CURRENT A.C. AMPS (RMS) (NOTE 6) 0.00 U2 DPM DP IN E0 E0 R0 K R05 0K R W R06 02 C05 22 C OUT CF (NOTE 8) 5.6V 5.6V 7 VS U02 AD76 T :2.26 IN CAV IN VS COM 8 2 E05 R07 72 RMS TO DC CONVERTER CW (NOTE ) mv AC PER AMP R7 K E5 R08 0K E07 E06 E C E0 E J OUTPUT CURRENT 0. V/AMP (INTO M OHM) REV A IMPROVED ACCURACY VOLTAGE MONITORING REPLACES U0 PRECISION RECTIFIER R CAL R20.0K % ASSY PS0A02 AC RECTIFIER RWRK BRD R20 M % R202 M % D20 N007 C20. 25VAC POLY R20 0K % TO J LINE TO J W Figure. Complete schematic for PS0A. 5
6 Material List PS0A00 Chassis Assembly Qty Designator Value/Type Description Part Number* Supplier C 0.0 µf, 50V Disc Ceramic F 0A, 250V AG 0.25 X.25 Fuse F2 5A, 250V AG 0.25 X.25 Fuse I V, 0.A Bayonet Type CM85 MOU J Receptacle, prong NEMA 55R 2 J2, J BNC Female, 50 Bulkhead P SJT Pwr Cord AWG, NEMA 55P R 0.05, 5%, 5W Lo Ind Curr Sense, IRC OAR 66OAR5R050JLF MOU S SPST 5A, 250V Toggle Switch S2 SPDT 5A, 250V Toggle Switch T 2 5A 7 VAC Transformer T2 5A Variac 7 VAC Variable T 7.77: Ratio 60 Hz Isolation Transformer T :2.26 Ratio 60 Hz Isolation Transformer 2 U, U2 ½ Digit Panel Meter 99.9 mv LCD PM28 2 XF, XF2 ¼ X ¼ Fuse Holder Panel Mount XI T ¼ Min. Bayonet Panel Mount Cable Clamp 0.0 I.D. Nylon Panel Bushing 0.0 I. D. Snap Nylon.9 Knob 0.75 Shaft Black w/ White Pointer Rubber Foot Heavy Duty 572 MOU Main Chassis Shop Built Pwr Cord Bracket Shop Built T2 Bracket 0.25 Al Rt Angle Front Panel Al Shop Built 0.25 X 0.75 # Screw Hex Standoff Enclosure Steel 8X8X2 * Items without a part number came from Shop stock. Most items are available from Mouser Electronics. 6
7 Material List PS0A0 PWB Assembly Qty Designator Value/Type Description Part Number* Supplier** 2 C0, C02 00 µf, 6 VDC Radial Aluminum 67UVZC0MDD C0, C0, C05 22 µf, 6 VDC Radial Aluminum 67UVRC220MDD C06 7 µf, 6 VDC Radial Aluminum 67UVRC70MDD C07.0 µf, 6 V Polyester Film 80R82DC00DQ60J 2 D0 D0 N00 A, 50 V Si Rectifier 2 D05, D06 N522B 5.6 V, 0.5 W Zener 78N522B D07 N5 Si Switching Diode 52N5 2 R0, R02 80 Carbon Film 2980RC 2 R0, R6 20 K, 0.25W, 5% Carbon Film 2920KRC 2 R0, R2 K, 0.25W, % Metal Film 27KRC R05, R08, R0 0 K, 0.25W, % Metal Film 270KRC R06, 0.25W, % Metal Film 2702RC R07, 0.25W, % Metal Film 2772RC R K, 0.25W, % Metal Film 272.7KRC R 6.9 K, 0.25W, % Metal Film 276.9KRC R K, 0.25W, % Metal Film 27KRC R 887 K, 0.25W, % Metal Film 27887KRC R5 00 K, 0.25W, % Metal Film 2700KRC 2 R7, R8 K Cermet Trimmer 62586F02LF T0 VAC 0. A 7 VAC PRI 2 U0, U0 DC Isolation Micro Current Supply PS90A W5BWC U02 AD76 Analog Devices RMS to DC Converter U0 LF5 Dual JFET Op Amp PWB PS0A20 W5BWC Material List PS0A02 Rework Assembly Qty Designator Value/Type Description Part Number* Supplier** C20.µF, 25VAC Polyester Film D20 N007 KV, A Si Rectifier R20 0 K, 0.25W, % Metal Film 2 R202, R20 M, 0.25W, % Metal Film R20. K, 0.25W, % Metal Film R , 0.5W 0 Turn Trimmer * Items without a part number came from Shop stock. Most items are available from Mouser Electronics. ** Part numbers are Mouser Electronics unless otherwise noted in Supplier column. 7
8 Prototype tests and notes Output (Volts) Voltage Display and Monitor Accuracy Display (%) Monitor (Volts) (%) Range Output (Amps) Range ± 0. % (tracking) ± 2 % (Composite) ± % (tracking) ± 2 % (Composite) Current Display and Monitor Accuracy Display (%) Monitor (Volts) (%) ± 2 % (.50 Amps) ± 0 ma (0.5.5Amps) ± 2 % (.50Amps) ± 0 ma (0.5.5 Amps) Voltage and Current monitor points are phase aligned to 0.2 ms out of 6.67 ms for.2% which appears to hold within ±.5% (± 5 Degrees). Output (Volts) Voltage Display Accuracy During warmup Display (Volts) Elapsed Time (Hrs:Mins) (%) : : : : : : : : : : : : : : : Note: T and T have a voltage nonlinearity that contributes to the error at the monitor points. T actually improves a slight nonlinearity in the precision rectifier, but imposes an error on the Voltage Monitor point. Notice the Current Monitor point tracks the Current display within a fraction of a percent, but the error contribution of T can be seen when the Current Monitor reading is compared to the actual output current. T also has a considerable warmup time that effects the Voltage Display and Monitor Point as can be seen from the above data. After one hour warmup the contribution of T stablizes and supports ± 2 % when the initial calibration is done at hours operation. T and T provide isolation for voltage and current measurements, but at the expense of accuracy. The transformers contribute significant inaccuracies in the PS0A. A Triad CSE current transformer might improve T, but the data sheet is too vague to be sure. T may need to be : 5 VAC 2.5 VA type with a 0: resistive divider on its primary side. Or 600 Ohm transformers could be used with the line Voltage divided by 00. Also, an RMS converter in place of the precision rectifier would improve harmonic induced errors in Voltage display. 8
9 Prototype tests and notes Data for Rev A modification that replaces the precision rectifier with a high Voltage rectifier and isolation resistors for the Voltage Display. The original transformer coupled circuit caused inconsistencies up to ± 2%. As seen by the following data the high voltage rectifier is within ± 0.5% over 90% of the instances that it was checked. The distribution of readings taken over several days reveals the following: Time Rdg Volts % : : : : : ReCal ReCal : : : : : : : : : : : : : : : Time Rdg Volts % 909 0: : : : : : : : : : : : : : : : : : : : Range Occurrences % In Range 0 ± 0. % 8 5 % 0 ± 0.25 % 2 60 % 0 ± 0.5 % 9% PERCENT ERROR Dynamic Range Accuracy Rdg Volts %
10 Notes: For Characteristics (page 2).. Input voltage below 20 VAC may not provide 0 VAC output under 5 Amp load. 2. Input current for the PS0A control circuitry is a fraction of an Amp.. Fuses are 5 Amp and 0 Amp. Extended periods at maximum current may cause one or the other to open. Also, R is at full rated dissipation at 0 amp.. Output Voltage display accuracy based on initial calibration after hours operation. 0
PS-40A-1 AC Bench Power Supply
PS0A Bench power supply capable of direct line or 2 to 0 VAC variable output. Fused output at 0 A for line and 5 A for variable output. Includes voltage and current displays and external monitor outputs.
More informationPS-15C-2 Power Supply Float Charger VDC at 0 to 25 ADC
13.8 VDC at 0 to 25 ADC W5BWC Electronics PS-15C-2 Power Supply Float Charger Designed to be used with MC-20A DC Buss Monitor and Control for a complete station power system. Disclaimer: This document,
More informationPS-17A-1 DC/DC SMPS Boost Regulator
PS-17A-1 DC/DC SMPS Boost Regulator PS-17A-1 DC/DC SMPS Boost Regulator The PS-17A-1 is a high efficiency switch mode power supply, providing a regulated output of 30 Amps* at 13.25 VDC from a 12 Volt
More informationModel 7000 Low Noise Differential Preamplifier
Model 7000 Low Noise Differential Preamplifier Operating Manual Service and Warranty Krohn-Hite Instruments are designed and manufactured in accordance with sound engineering practices and should give
More informationPM124 Installation Instructions. See important note about revisions of this board on the last page.
Marchand Electronics Inc. PO Box 473, Webster, NY 14580 Tel:(716) 872-0980 Fax:(716) 872-1960 info@marchandelec.com http://www.marchandelec.com (c)1997 Marchand Electronics Inc. PM124 Installation Instructions
More information411LA Broadband Power Amplifier
411LA Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More informationPractical Tricks with Transformers. Larry Weinstein K0NA
Practical Tricks with Transformers Larry Weinstein K0NA Practical Tricks with Transformers Quick review of inductance and magnetics Switching inductive loads How many voltages can we get out of a $10 Home
More informationOPERATING AND MAINTENANCE MANUAL
5Hz to 1MHz WIDE RANGE FULLY AUTOMATIC DISTORTION ANALYZER MODEL 6900B SERIAL NO. OPERATING AND MAINTENANCE MANUAL Unit 4, 15 Jonathan Drive, Brockton, MA 02301-5566 Tel: (508) 580-1660; Fax: (508) 583-8989
More informationBroadband Power Amplifier
601L Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More informationCALRAD 25 series - potentiometers
25 series - potentiometers audio /linear SUB-MINIATURE VOLUME CONTROLS Linear taper, extremely smooth for quiet operation. 1 2" dia. fits into 1 4" hole. Shaft 3 16" dia. Thread length 7 32", shaft length
More informationAPPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS
APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS DC POWER SUPPLIES We will discuss these instruments one at a time, starting with the DC power supply. The simplest DC power supplies are batteries which
More informationModel Hz to 10MHz Precision Phasemeter. Operating Manual
Model 6610 1Hz to 10MHz Precision Phasemeter Operating Manual Service and Warranty Krohn-Hite Instruments are designed and manufactured in accordance with sound engineering practices and should give long
More informationAP-10A-1 ARS Portable Power Unit
AP-10A-1 ARS Portable Power Unit AP-10A-1 ARS Portable Power Unit AP-10A-1 Portable Power Unit A desk top power unit designed to operate a 100 Watt HF ARS (Amateur Radio Station) from its internal 12 Volt
More informationIsolated Variable AC Line Supply Instruction Manual
1506 Isolated Variable AC Line Supply Instruction Manual 10/2011 TABLE OF CONTENTS SECTION DESCRIPTION PAGE NO. 1 INTRODUCTION 1 2 SPECIFICATIONS 2 3 DESCRIPTION 3 4 OPERATING INSTRUCTIONS 5 5 SERVICE
More informationDST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL
DST-2000C Direction Sensing Tachometer INSTRUCTION MANUAL Azonix-Dynalco, 3690 N. W. 53 Street, Ft. Lauderdale, FL 33309 U.S.A.! (954) 739-4300 Fax (954) 484-3376 www.dynalco.com mailbox@dynalco.com October
More informationDVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding
BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER User Manual Gebruikershandleiding Manuel d'utilisation Gebrauchsanleitung Introduction BENCH MULTIMETER This manual
More informationModel 4402B. Ultra-Pure Sinewave Oscillator 1Hz to 110kHz Typical Distortion of % Serial No. Operating Manual
Model 4402B Ultra-Pure Sinewave Oscillator 1Hz to 110kHz Typical Distortion of 0.0005% Serial No. Operating Manual 15 Jonathan Drive, Unit 4, Brockton, MA 02301 U.S.A. Tel: (508) 580-1660; Fax: (508) 583-8989
More informationThe University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization
The University of Jordan Mechatronics Engineering Department Electronics Lab.(0908322) Experiment 1: Lab Equipment Familiarization Objectives To be familiar with the main blocks of the oscilloscope and
More informationCALRAD MINIATURE MULTI-CLICK DUAL CONTROLS 40 STEP P.C. MOUNT 11
25 Series - Potentiometers Audio & Linear SUB-MINIATURE VOLUME CONTROLS Linear taper, extremely smooth for quiet operation. 1 /2" dia. fits into 1 /4 hole. Shaft 3 /16" dia. Thread length 7 /32", shaft
More informationContents. 1 Block Diagram. 2 Specifications. 3 Unipolar vs. Bipolar Interconnections. 4 Inexpensive Bipolar Power Supply Alternative.
Contents 1 Block Diagram 2 Specifications 3 Unipolar vs. Bipolar Interconnections 4 Inexpensive Bipolar Power Supply Alternative 5 PCB Layout 6 Calibration 7 Current Source-Sink Units Connected in Parallel
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading
More informationHow The Transmitter Works
Mike Bray, K8DDB Refer to the schematic of the transmitter on page 7 of the manual. The crystal-controlled oscillator, V generates a small amount of r.f. power which is used to drive the amplifier, V2.
More informationThe 6LE8 One Tube Broadcaster
The 6LE8 One Tube Broadcaster Introduction The purpose of this broadcaster is to transmit your favorite music to every AM radio in your home. The transmitting power is so low that it should not bother
More informationPOWER AMPLIFIER SERVICE MANUAL CONTENTS
POWER LIFIER CONTENTS Performance Specifications... 2 Notes... 2 Rear Panel... 3 Section Location... 4 Block Diagram... 5-6 Interconnection Diagram... 7-8 Input PCB and Schematic... 9-10 Main PCB and Schematic...
More information10 2 2,13,15,16,46 27, non-inductive ,26,
HANDS-ON RADIO PARTS LIST (Thanks, John AF4WM and Steve AD7KR) Updated through Experiment 129 Quantities assume all parts available for re-use MAX QTY EXPERIMENT NOTES 1/4 WATT RESISTOR (All values are
More information201AP Charge Amplifier User Manual
Trig-Tek 201AP Charge Amplifier User Manual Publication No. 980996 Rev. A Astronics Test Systems Inc. 4 Goodyear, Irvine, CA 92618 Tel: (800) 722-2528, (949) 859-8999; Fax: (949) 859-7139 atsinfo@astronics.com
More informationINSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer
INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer 110 Toledo Street Farmingdale, NY 11735 USA http://www.netech.org 510-USER-Manual Rev3 10/29/2007 Dear User, We appreciate your purchase of the LKG
More informationWRM-10 TM TRANSFORMER WINDING RESISTANCE METER
WRM-10 TM TRANSFORMER WINDING RESISTANCE METER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 June 2009 Revision
More informationMAINTENANCE MANUAL MHz, 100 WATT POWER AMPLIFIER 19D901841G2
D MAINTENANCE MANUAL 851-870 MHz, 100 WATT POWER AMPLIFIER 19D901841G2 TABLE OF CONTENTS Page DESCRIPTION................................................ Front Cover CIRCUIT ANALYSIS.............................................
More informationUSER'S MANUAL DMR-6700
USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
More informationEar+ Purist HD. Ear+ HD II High Definition Stereo Headphone Amplifier
Ear+ Purist HD Ear+ HD II High Definition Stereo Headphone Amplifier Users' Manual Rev Mar 8/19 Mapletree Audio Design R. R. 1, Seeley's Bay, Ontario, Canada, K0H 2N0 (613) 387-3830 www.mapletreeaudio.com
More informationDSTS-3B DEPTHSOUNDER TEST SET OPERATOR S MANUAL
Page 1 1.0 INTRODUCTION DSTS-3B DEPTHSOUNDER TEST SET OPERATOR S MANUAL The DSTS-3B is a full-featured test set designed for use with all types of echo sounders from small flashers to large commercial
More informationPOWER AMPLIFIER SERVICE MANUAL CONTENTS
POWER AMPLIFIER CONTENTS Performance Specifications... 2 Notes... 2 Rear Panel... 3 Section Location... 5 Block Diagram... 6 Interconnection Diagram... 7-8 Input Schematic and PCB... 9-12 Heatsink 1-Channel
More informationMASTERFLEX L/S ECONOMY 200 RPM DRIVE 115 VOLT MASTERFLEX L/S ECONOMY 200 RPM DRIVE 230 VOLT
MODELS: ********SERVICE MANUAL******** 7554-80 MASTERFLEX L/S ECONOMY 200 RPM DRIVE 115 VOLT 7554-85 MASTERFLEX L/S ECONOMY 200 RPM DRIVE 230 VOLT 7554-90 MASTERFLEX L/S ECONOMY 600 RPM DRIVE 115 VOLT
More informationPM24 Installation Instructions
Marchand Electronics Inc. PO Box 473, Webster, NY 14580 Tel:(716) 872-0980 Fax:(716) 872-1960 info@marchandelec.com http://www.marchandelec.com (c)1997 Marchand Electronics Inc. PM24 Installation Instructions
More informationTO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-F
TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-F NEW Signal Powered or 5-28VDC Powered FLAT PACK PANEL METERS NEED NO PANEL CUT OUT > 40 INPUT SIGNALS ACCEPTED MODEL FPM FEATURES: 4
More informationB MTS Systems Corp., Model Function Generator
0189 115585-02 B MTS Systems Corp., 1988 Model 410.81 Function Generator Table of Contents Section 1 Introduction 1.1 Functional Description 1-1 1.2 Specifications 1-2 Section 2 Operation 2.1 Control Mode
More informationMaintenance Manual CHANNEL GUARD ENCODER/DECODER 19D430740G1 TONE REJECT FILTER 19D430740G4. Mobile Communications
E ********* (REPLACES LBI-4143) Mobile Communications CHANNEL GUARD ENCODER/DECODER 19D430740G1 TONE REJECT FILTER 19D430740G4 Printed in U.S.A. Maintenance Manual TABLE OF CONTENTS SPECIFICATIONS..................................................
More informationtransformer rectifiers
Power supply mini-project This week, we finish up 201 lab with a short mini-project. We will build a bipolar power supply and use it to power a simple amplifier circuit. 1. power supply block diagram Figure
More informationD. Gillespie Designs. SCA-35 Capacitor Board. Installation Manual. D. Gillespie Designs with EFB TM
D. Gillespie Designs SCA-5 Capacitor Board with EFB TM Installation Manual D. Gillespie Designs www.tronola.com Thank you for choosing our SCA-5 Capacitor Board with *EFB. We feel it is the single most
More informationTested Tough. Trusted Safe.
TEST & MEASUREMENT Tested Tough. Trusted Safe. TOUGH METER Clamp Meters............................. 2-3 KLEIN TEST & MEASUREMENT Klein Tools has been manufacturing professional hand tools for almost 160
More informationEXAMPLE. Use this jack for the red test lead when measuring. current from 0 to 200mA. Figure P-1
Digital Multimeters ON / OFF power switch Continuity / Diode Test Function Resistance Function Ranges from 200Ω to 200MΩ Transistor Test Function DC Current Function Ranges from 2mA to 20A. AC Current
More informationSignal Conditioning Amplifier
2300 System Micro-Measurements FEATURES Accepts all strain gage inputs (foil and piezoresistive), potentiometers, DCDT s, etc Selectable bridge excitation, 0.7 to 15 VDC (11 steps), plus 0.2 to 7 VDC continuously
More informationModel LIA100. Lock-in Amplifier
Model LIA100 Lock-in Amplifier Operations Manual Thorlabs, Inc 435 Route 206 Newton, NJ 07860 P-(973) 579-7227 F-(973) 300-3600 www.thorlabs.com Doc. Page 1 of 10 Table of Contents Chapter Description
More informationHAMTRONICS TB901 FM EXCITER INSTALLATION, OPERATION, & MAINTENANCE
HAMTRONICS TB901 FM EXCITER INSTALLATION, OPERATION, & MAINTENANCE GENERAL INFORMATION. The TB901 is a single-channel low power fm transmitter (exciter) designed to provide 300-600 milliwatts continuous
More informationLBI-4938C. Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3. Printed in U.S.A. Maintenance Manual
C Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3 Printed in U.S.A. Maintenance Manual TABLE OF CONTENTS DESCRIPTION.................................................... 1 CIRCUIT ANALYSIS.................................................
More informationFEB User s Guide Power Factor Corrected 500W Off-Line Power Supply
FEB108-001 User s Guide Power Factor Corrected 500W Off-Line Power Supply Featured Fairchild Product: FAN4810 www.fairchildsemi.com/febsupport Contents 1. General Board Description...3 1.1 Contents of
More informationOPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER
OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate
More informationSERVICE MANUAL. Subwoofer Amplifier Model: SW12-I SW15-I KLIPSCH, INC.
SERVICE MANUAL Subwoofer Amplifier Model: SW12-I SW15-I KLIPSCH, INC. TABLE OF CONTENTS SPECIFICATIONS...2 Model: SW12-I...2 Model: SW15-I...2 THEORY OF OPERATION... 3 INPUTS... 3 SIGNAL CONDITIONING...
More informationICF-C112 SERVICE MANUAL FM/AM CLOCK RADIO. E Model. Ver Sony Corporation SPECIFICATIONS
SERVICE MANUAL E Model Ver 1.0 2003. 03 SPECIFICATIONS Time display: 12-hour system Frequency range: : 87.5-108 MHz AM: 530-1710 khz Speaker: Approx. 6.6 cm (2 5/8 inches) dia., 8 ohm Power output: 120
More informationCOM-POWER OPERATION MANUAL ACS W
COM-POWER OPERATION MANUAL For the ACS-250-100W 150 khz to 250 MHz 100W Power Amplifier Page 1 of 15 MANUAL_ACS-250-100W Rev. M02.15 Table of Contents Important Safety Precautions.....3 Introduction..5
More informationModel ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com
Model ST-9933 True RMS Autoranging Digital Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-8 Technical...4-5 Accuracy...5-8 Display Description...
More informationMicroprocessor Control Board Set Up Procedures (OR PLC)
Microprocessor Control Board Set Up Procedures (OR-00 PLC) SWITCHES/PUSHBUTTONS Push Buttons at display SW Enter button SW Back button SW Down SW UP Back light on/off switch Rotary switches on main board
More informationPOWER SUPPLY MODEL XP-720. Instruction Manual ELENCO
POWER SUPPLY MODEL XP-720 Instruction Manual ELENCO Copyright 2016, 1997 by ELENCO Electronics, Inc. All rights reserved. Revised 2016 REV-H 753270 No part of this book shall be reproduced by any means;
More informationERICSSONZ LBI-38638C MAINTENANCE MANUAL FOR POWER MODULE 19D902589G1 DESCRIPTION CIRCUIT ANALYSIS TABLE OF CONTENTS FILTERED A+
LBI-38638C MAINTENANCE MANUAL FOR 19D902589G1 TABLE OF CONTENTS Page DESCRIPTION........................................... Front.. Cover CIRCUIT ANALYSIS........................................ Front..
More informationAn Electronic Watt-Watt-Hour Meter
An Electronic Watt-Watt-Hour Meter The continued emphasis on energy conservation has forced designers to consider the power consumption and efficiency of their products. While equipment for the industrial
More informationINSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.
INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. MANUAL PART NUMBER 180-0036 ORIGINAL: 1-17-83 REVISION: B (8-26-86) NOT TO BE CHANGED WITHOUT MSHA
More informationFOXCART 400 MARK II OPERATION AND SERVICE MANUAL FOXTRONICS LOVE FIELD - DALLAS TEXAS MODEL PR APPROX. 550POUNDS THE POWER CART WITH MUSCLE
FOXCART 400 MARK II OPERATION AND SERVICE MANUAL MODEL PR2400-400 APPROX. 550POUNDS THE POWER CART WITH MUSCLE FOXTRONICS LOVE FIELD - DALLAS TEXAS MADE IN THE USA 3448 WEST MOCKINGBIRD LANE DALLAS, TEXAS
More informationUsing Circuits, Signals and Instruments
Using Circuits, Signals and Instruments To be ignorant of one s ignorance is the malady of the ignorant. A. B. Alcott (1799-1888) Some knowledge of electrical and electronic technology is essential for
More informationSERVICE MANUAL 2 CHANNEL POWER AMPLIFIER GFA-5400
SERVICE MANUAL 2 CHANNEL POWER AMPLIFIER GFA-5400 TABLE OF CONTENTS Introduction...1 Version 1 vs. Version 2........ 1 Test Procedures............. 1 Parts List...2 Specifications...6 Chassis Layout...............
More informationThe ROSE 80 CW Transceiver (Part 1 of 3)
Build a 5 watt, 80 meter QRP CW Transceiver!!! Page 1 of 10 The ROSE 80 CW Transceiver (Part 1 of 3) Build a 5 watt, 80 meter QRP CW Transceiver!!! (Designed by N1HFX) A great deal of interest has been
More informationModel 1791 VHF Radio User's Manual
Model 79 VHF Radio User's Manual ALL WEATHER INC 65 NATIONAL DRIVE SACRAMENTO, CA 95834 WWW.ALWEATHERINC.COM 79 VHF RADIO USER'S MANUAL CONTENTS INTRODUCTION... Description... Transmitter Module... Power
More informationMAINTENANCE MANUAL MHz, 100 WATT POWER AMPLIFIER 19D901841G3
MAINTENANCE MANUAL 851-870 MHz, 100 WATT POWER AMPLIFIER 19D901841G3 TABLE OF CONTENTS SPECIFICATIONS............................................... Front Cover DESCRIPTION.................................................
More informationAn American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.
An American Control Electronics Brand PCM4 SERIES PCM4 USER MANUAL www.minarikdrives.com Dear Valued Consumer: Congratulations on your purchase of the PCM4 Series isolation card. This User Manual was created
More informationMW3105 DIGITAL CLAMP MULTIMETER
MW3105 DIGITAL CLAMP MULTIMETER 2 M MW3105 A 01 INTRODUCTION 1.1 - Unpacking and inspection Upon removing your new Digital Clamp Meter from its packing, you should have the following items: 1. Digital
More informationINSTRUCTION MANUAL. March 11, 2003, Revision 3
INSTRUCTION MANUAL Model 701A Stimulator March 11, 2003, Revision 3 Copyright 2003 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit 4 Aurora, Ontario, Canada L4G 3V7 Tel: 1-905-727-5161
More informationExercise 2: FM Detection With a PLL
Phase-Locked Loop Analog Communications Exercise 2: FM Detection With a PLL EXERCISE OBJECTIVE When you have completed this exercise, you will be able to explain how the phase detector s input frequencies
More informationModel SR554 Transformer Preamplifier
Model SR554 Transformer Preamplifier Model SR554 Transformer Preamplifier 1290-D Reamwood Avenue Sunnyvale, California 94089 Phone: (408) 744-9040 Fax: (408) 744-9049 email: info@thinksrs.com www.thinksrs.com
More informationOPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE
OPERATION & SERVICE MANUAL FOR FC 100 SERIES AC POWER SOURCE FC 110 AC POWER SOURCE VERSION 1.3, April 2001. copyright reserved. DWG No. FC00001 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 1.1 GENERAL...
More informationCAT4237EVAL2 Evaluation Board for CAT4237 High Voltage White LED Driver
Application Note 24 CAT4237EVAL2 Evaluation Board for CAT4237 High Voltage White LED Driver Denisa Stefan, Applications Engineering Manager denisa.stefan@catsemi.com INTRODUCTION This document describes
More informationCatalog Number 724 ESP-8MC / ESP-12MC / ESP-16MC / ESP-24MC ESP-28MC / ESP-32MC / ESP-36MC / ESP-40MC
OUTDOOR LAWN SPRINKLER CONTROL MODEL: INPUT: 230 VAC 50/Hz 0.3 AMP OUTPUT: Datecode: 28AU9801 ASSEMBLED IN MEXICO P/N: 634385 This device complies with Part 15 of the FCC Rules. Operation is subject to
More informationProcess Calibrator. TechChek 820
Process Calibrator TechChek 80 CONTENTS GENERAL... TURN ON... CONNECTIONS... TILT STAND...4 CHANGING BATTERIES...4 RESTORING DEFAULT SETTINGS... CONFIGURING TEMPERATURE SCALES... ENABLING AUTO-OFF... SELECTING
More informationCT-2 and CT-3 Channel Taggers OPERATION MANUAL
CT-2 and CT-3 Channel Taggers OPERATION MANUAL Trilithic Company Profile Trilithic is a privately held manufacturer founded in 1986 as an engineering and assembly company that built and designed customer-directed
More informationR208 Microstepping Driver. User Manual Version 1.3. Lin Engineering Vineyard Blvd, Morgan Hill, CA 95037
R208 Microstepping Driver User Manual Version 1.3 Lin Engineering 16245 Vineyard Blvd, Morgan Hill, CA 95037 Thank you for purchasing the R208 driver. This product is warranted to be free of manufacturing
More informationMAINTENANCE MANUAL MHz, 100 WATT POWER AMPLIFIER 19D901841G3
A MAINTENANCE MANUAL 851-870 MHz, 100 WATT POWER AMPLIFIER 19D901841G3 TABLE OF CONTENTS SPECIFICATIONS............................................... Front Cover DESCRIPTION.................................................
More informationModel Operating Manual
Model 7500 DC to 1MHz Wideband Power Amplifier Operating Manual Copyright 2004. All rights reserved. Contents of this publication may not be reproduced in any form without the written permission of Krohn-Hite
More information200Amp AC Clamp Meter + NCV Model MA250
User's Guide 200Amp AC Clamp Meter + NCV Model MA250 Introduction Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance,
More informationV1.3. TBLC08 50mH AC-LISN TBLC08
V1.3 TBLC08 The TBLC08 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR16 standard. The device is designed
More informationSI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5
SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 Phone: (905) 564-0801 Fax: (905) 564-0806 www.telecor.com E:\T2-108\T2-M108-ABC\T2-M108-B.doc/AD
More informationMANUAL UPDATING CHANGES CHANGE DATE: June 16, 2004
MANUAL UPDATING CHANGES CHANGE DATE: June 16, 2004 MANUAL IDENTIFICATION MANUAL UPDATING COVERAGE This supplement adapts your manual to Serial Numbers prefixed through: 3708A Instrument: HP 5087A Distribution
More informationUNITED MOTORS SERVICE. DIVISION OF GENERAL MOTORS CORPORATION General Offices - Detroit AUTO RADIO BULLETIN
UNITED MOTORS SERVICE DIVISION OF GENERAL MOTORS CORPORATION General Offices - Detroit AUTO RADIO BULLETIN Bulletin 6D-848 Chevrolet 986515 Page 1 SUBJECT: SERVICE INSTRUCTIONS CHEVROLET CUSTOM DELUXE
More informationGeneral Application Notes Remote Sense Remote On / Off Output Trim Series Operation Parallel Operation...
General... 28 Remote Sense... 29 Remote On / Off... 30 Output Trim... 30 Series Operation... 32 Parallel Operation... 33 Synchronization... 33 Power Good Signal... 34 Electro Magnetic Filter (EMI)... 34
More informationAC Current Monitor model ACM-2
1.0 Safety Warnings The ACM-2 AC Current Monitor should be installed only by qualified technical personnel with knowledge of industrial electrical wiring and the requirements of the national and local
More informationDigital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE
Digital Panel Meter K3TE Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display with
More informationYaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW)
Yaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW) Page 1 Section Two: Power Checks Page 2 Check box when completed Power Checks TEST
More informationFryKleaner Pro Audio Burn-in Generator
HAGERMAN T E H N O L O G Y FryKleaner Pro Audio Burn-in Generator FryKleaner Pro Kit Manual 2 Warnings This product does not use any dangerous voltages. Power is supplied from a UL listed 15V wall-wart.
More informationDIGITAL / ANALOG TRAINER
DIGITAL / ANALOG TRAINER MODEL XK-150 A COMPLETE MINI-LAB FOR BUILDING, TESTING AND PROTOTYPING ANALOG AND DIGITAL CIRCUITS Instruction Manual ELENCO Copyright 2016, 1998 by ELENCO Electronics, Inc. All
More informationCALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz
INSTRUCTION MANUAL CALIBRATED IMPULSE GENERATOR MODEL CIG-25 10 khz 1 GHz INSTRUCTION MANUAL THIS INSTRUCTION MANUAL AND ITS ASSOCIATED INFORMATION IS PROPRIETARY. UNAUTHORIZED REPRODUCTION IS FORBIDDEN.
More informationUser s Manual for Integrator Short Pulse ISP16 10JUN2016
User s Manual for Integrator Short Pulse ISP16 10JUN2016 Specifications Exceeding any of the Maximum Ratings and/or failing to follow any of the Warnings and/or Operating Instructions may result in damage
More informationPE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments
Electrical Machine / Power Electronics PE-5000 Power Electronics Training System The PE-5000 Power Electronics Training System consists of 28 experimental modules, a three-phase squirrel cage motor, load,
More informationSummit Audio Model EQP-200B Dual Program Equalizer Operating Manual
Summit Audio Model EQP-200B Dual Program Equalizer Operating Manual IMPORTANT!: CAREFULLY READ THE ENTIRE INSTRUCTION MANUAL BEFORE HOOKUP OR OPERATION OF THE EQP-200B. WARNING!: HIGH VOLTAGE. THIS UNIT
More informationConstruction notes for the symmetrical 400 watt amplifier
Construction notes for the symmetrical 400 watt amplifier Introduction The symmetrical amplifier is an update of one of my designs, which appeared in the Australian electronics magazine Silicon Chip in
More information81357 Series PFC Boost Module Application Information
81357 Series PFC Boost Module Application Information OVERVIEW Implementing power factor correction (PFC) into switch mode power supplies maximizes the power handling capability of the power supply and
More information79/26 Series III Multimeter
79/26 Series III Multimeter Instruction Sheet W Read First: Safety Information Never use the meter if the meter or test leads look damaged. Be sure the test leads and switch are in the correct position
More informationMFJ 259 Operation & Simplified Calibration
MFJ 259 Operation & Simplified Calibration Bill Leonard N0CU NA0TC 2014 TechFest 1 What Will Be Covered Part 1: Operation What is an MFJ 259 What Does It Measure Impedance & Admittance How Does It Work
More informationSignal Conditioning Amplifier
FEATURES Plug-in amplifier design; amplifiers are removable from the front panel without rear access Constant-voltage or constant-current excitation; 0.5 to 15 V or 0.5 to 30 ma; selectable by single internal
More informationUser s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130
User s Guide MultiView Series Digital MultiMeters Models: MV110 MV120 MV130 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year
More informationNot for Reproduction
1 ADVANCE PRODUCT SERVICE INFORMATION SUBJECT: OPERATING PROCEDURES FOR EXTECH DIGITAL MULTIMETER No: #66 DATE: 05/31/2010 MODELS: 19602 DIGITAL MULTIMETER A digital multimeter is necessary for electrical
More informationMASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2. Maintenance Manual LBI-30766L. Mobile Communications
L Mobile Communications MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2 Printed in U.S.A Maintenance Manual TABLE OF CONTENTS Page SPECIFICATIONS.....................................................
More informationPB63 PB63A. Dual Power Booster Amplifier PB63
Dual Power Booster Amplifier A FEATURES Wide Supply Range ± V to ±75 V High Output Current Up to 2 A Continuous Programmable Gain High Slew Rate 1 V/µs Typical Programmable Output Current Limit High Power
More information