MEMS Test & Reliability Conference. Dynamic Product Performance Testing of Capacitive MEMS Elements at Wafer Level
|
|
- Derek Ramsey
- 6 years ago
- Views:
Transcription
1 MEMS Test & Reliability Conference Dynamic Product Performance Testing of Capacitive MEMS Elements at Wafer Level
2 Solidus Technologies Abstract Testing the electro/mechanical behavior of capacitive MEMS elements (accelerometers, gyros, mirrors, microphones and resonators) is a requirement for verifying and screening for performance of the MEMS element. This presentation will provide information on an innovative test methodology that can empirically determine, record, and analyze the MEMS element s dynamic electro/mechanical behavior or response through electrical stimulation and sensing at wafer level testing. This dynamic test method provides a fast reliable and cost effective method to extract product behavior data from the element at wafer level which can be used to sort MEMS products for performance, determine fabrication process variation and establish Known Good Die (KGD).
3 Agenda 1. What is Dynamic Wafer Level Testing? 2. Why is Dynamic Wafer Testing Important? 3. Measurement Overview 4. Conventional Measurement Methods 5. Dynamic Measurement Methods 6. Dynamic Measurement Data Analysis 7. Summary
4 What is Dynamic Level Wafer Testing? The ability to move a MEMS element at wafer level with a Drive Voltage and then Sense or Measure the element s movement or behavior (Natural Frequency, Damping Ratio, Q, Quadrature Error, obstruction, Stiction and more. Drive or Force (Device Input) Sense or Measure (Device Output) Slope = Damping Ratio, Zeta and Q (Volts) (Time Units) f = 1/t (Time Units)
5 Why is Wafer Level Dynamic Testing Important? Reduce product development and deployment cycle time Provides process performance feed back to foundry Minimize or eliminate package stimulus testing Package stimulus handling equipment is capital intensive ($$) Package testing process is lengthy and expensive ($$) Reduce package test times using know good die Reduces existing wafer test time (3-4X) Increases wafer test coverage Sort die for dynamic performance Improves product quality Sort die for Known Good Die (KND) *Goal: Reduce Cost of Final Test and Overall Product Cost
6 Why is Wafer Level Dynamic Testing Important? (Continued) *Goal: Reduce Cost of Final Test and Overall Product Cost Static Wafer Test Path Package Test ($$$) - Calibration and Test Times ($$$) - Final Test Yields ($$$) - Tester and Handler ($$$) Dynamic Wafer Test Path Dynamic Wafer Test ($$) Minimize Parameter Variations Wafer Element KGD Wide Parameter Variations Wafer Element Static Wafer Test ($$) - Reduce Calibration Test Times - Increase Final Test Yields - Minimize Final Testing - Wafer processing Improvement - Minimize Process Variation Package Test ($$)
7 Measurement Overview MEMS Wafer level dynamic testing has increased in importance as products have become more complicated, and production volumes increase. Validate device design & simulations. Predict final device performance at wafer level. Improve MEMS fabrication process and yields. Reduce Overall Manufacturing Costs Products that benefit from Dynamic Measurement: Capacitive Inertial devices: Gyro, accelerometers, IMU s. Pressure sensors, Optical Mirrors, MEMS microphones.
8 Dynamic Measurement Methods Dynamic Methods Frequency Response Resonant Frequency Spring Constant Damping Q Gyro Quadrature error Mechanical Hysteresis Work function potential (ev) Dynamic Attributes AC Performance Failures and Defects Stiction Particulate obstruction Broken elements Hermiticity Meets design specifications? Sort for performance STI9000 ATE STI3000E Test Head
9 Dynamic Measurement Methods Test Flow Test Flow Example Leakage Test Step Response Range of Motion f - 3 db Test O u t p u t O u t p u t O u t p u t O u t p u t Leakage Currents Test Output Resonant Frequency Q, Damping Ratio ; Spring Constant ; Snap Voltage, Hysteresis ; More... f - 3 db freq.
10 Dynamic Measurement Methods Test Times Example Test Flow Data Processing Leakage Test Step Response Range of Motion f - 3 db Test DLL Functions Call 0. 1 s s 0.10 s s 0 s Time Estimated Total Test Time (per die pair) < sec. Note: Test times are estimates and based on MEMS element structures: both accelerometers and gyros wafer elements were used as a benchmark. Dynamic testing typical < 30% of Capacitive Test Time Time
11 Dynamic Measurement Methods Types of Drive and Sense Tests STEP Test Resonant Frequency, Q, Damping Ratio, Hermiticity RAMP Test Stiction, Hysteresis, Spring Rate SWEEP Test Frequency Response, f- 3dB Frequency, Q Chirp Test White Noise Many Other Tests Possible
12 (Volts) Dynamic Measurement Test Methods STEP Response Test Example Drive or Force (Device Input) Sense or Measure (Device Output) Slope = Damping Ratio, Zeta and Q Sine Fit Correlation (Time Units) Measure Element Zeta & Q: 1. No-damping 2. Under-damped 3. Critically-damped 4. Over-damped f = 1/t (Time Units) Measure Element Phase Response
13 Dynamic Measurement Test Methods STEP Test Example Note: Test Data from STI3000 Test System
14 Dynamic Measurement Test Methods Range of Motion Test (ROM) Drive or Force (Device Input) Sense or Measure (Device Output) Stiction Point (Volts) (Device Output) Hysteresis (Time Units) (Volts) Voltage At Release Voltage At Pull-in
15 Dynamic Measurement Test Methods SWEEP Test Example Frequency Sweep Resonant Frequency and Q Force SWEEP Sinusoidal Voltage Input Measure Device Output Response Calculate Resonant Frequency and Q Sinusoidal Drive Input Device Resonance Device Roll-off Device Output (Amplitude) Resonant Frequency Frequency (Hz) Note: Test Data from STI3000 Test System
16 Standard Measurement Wafer and Package Testing Long and Expensive Development and Manufacturing Cycle Design Process Static Wafer Test Assembly Package Test
17 Dynamic Measurement Cost Savings with Dynamic Wafer Testing Design Performance Feedback Improve Design Improve Product with Process Improve Product with Test Performance Improve Product Quality Design Process $$$ Dynamic Wafer Test $$$ Monitor Process Correlation Wafer Test to Process Reduce Process Variation Validate Process with Wafer Test Distributions $$$ Reduce Manufacturing Costs Reduce Overall MFG Costs With Dynamic Wafer Testing Assembly Package Test Correlate Wafer to Final Test Reduce Final Test Times Reduce Final Tests Times Improve Final Test Yields Increase UPH Package Test is an Expensive MFG Constraint! Dynamic Wafer Testing improves product quality and reduces Package Testing time.
18 Summary Wafer Level Dynamic Performance data will: Reduce Overall Test Time for Wafer and Package Testing Provides Data to Reduce Product Variation Increase Product Yields Reduce Package Level Calibration and Testing Reduce Product Time to Market Validate Design Simulations Allow product to be sorted for product performance Reduce or eliminate package stimulus testing Decrease manufacturing costs while simultaneously improving product quality and reliability and increasing manufacturing through- put
19 Solidus Technologies, Inc. STI3000 Production Test Systems STI3000 Test Head STI9000 ATE
MEMS. Platform. Solutions for Microsystems. Characterization
MEMS Characterization Platform Solutions for Microsystems Characterization A new paradigm for MEMS characterization The MEMS Characterization Platform (MCP) is a new concept of laboratory instrumentation
More informationMEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs
MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs Application Note Recently, various devices using MEMS technology such as pressure sensors, accelerometers,
More informationKeysight Technologies MEMS On-wafer Evaluation in Mass Production
Keysight Technologies MEMS On-wafer Evaluation in Mass Production Testing at the Earliest Stage is the Key to Lowering Costs Application Note Introduction Recently, various devices using MEMS technology
More informationA NOVEL METHOD FOR FATIGUE TESTING OF MEMS DEVICES CONTAINING MOVABLE ELEMENTS
Stresa, Italy, 5-7 April 007 A NOVEL METHOD FOR FATIGUE TESTING OF MEMS DEVICES CONTAINING MOVABLE ELEMENTS Z. Szűcs, M. Rencz Budapest University of Technology and Economics (BME), Department of Electron
More informationCapacitive Versus Thermal MEMS for High-Vibration Applications James Fennelly
Capacitive Versus Thermal MEMS for High-Vibration Applications James Fennelly Design engineers involved in the development of heavy equipment that operate in high shock and vibration environments need
More informationThe Advantages of Integrated MEMS to Enable the Internet of Moving Things
The Advantages of Integrated MEMS to Enable the Internet of Moving Things January 2018 The availability of contextual information regarding motion is transforming several consumer device applications.
More informationFailure Modes for Stiction in Surface-Micromachined M:EMS
1998 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising
More informationDynamic Angle Estimation
Dynamic Angle Estimation with Inertial MEMS Analog Devices Bob Scannell Mark Looney Agenda Sensor to angle basics Accelerometer basics Accelerometer behaviors Gyroscope basics Gyroscope behaviors Key factors
More informationMechanical Spectrum Analyzer in Silicon using Micromachined Accelerometers with Time-Varying Electrostatic Feedback
IMTC 2003 Instrumentation and Measurement Technology Conference Vail, CO, USA, 20-22 May 2003 Mechanical Spectrum Analyzer in Silicon using Micromachined Accelerometers with Time-Varying Electrostatic
More informationModule 2: Lecture 4 Flight Control System
26 Guidance of Missiles/NPTEL/2012/D.Ghose Module 2: Lecture 4 Flight Control System eywords. Roll, Pitch, Yaw, Lateral Autopilot, Roll Autopilot, Gain Scheduling 3.2 Flight Control System The flight control
More informationFast radio interferometric measurement on low power COTS radio chips A. Bata, A. Bíró, Gy. Kalmár and M. Maróti University of Szeged, Hungary
Fast radio interferometric measurement on low power COS radio chips A. Bata, A. Bíró, Gy. Kalmár and M. Maróti University of Szeged, Hungary ÁMOP-...A-//KONV-0-007: elemedicine oriented research in the
More informationAC Circuits. "Look for knowledge not in books but in things themselves." W. Gilbert ( )
AC Circuits "Look for knowledge not in books but in things themselves." W. Gilbert (1540-1603) OBJECTIVES To study some circuit elements and a simple AC circuit. THEORY All useful circuits use varying
More informationRF MEMS Simulation High Isolation CPW Shunt Switches
RF MEMS Simulation High Isolation CPW Shunt Switches Authored by: Desmond Tan James Chow Ansoft Corporation Ansoft 2003 / Global Seminars: Delivering Performance Presentation #4 What s MEMS Micro-Electro-Mechanical
More informationSolution of Pipeline Vibration Problems By New Field-Measurement Technique
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1974 Solution of Pipeline Vibration Problems By New Field-Measurement Technique Michael
More informationReference Diagram IDG-300. Coriolis Sense. Low-Pass Sensor. Coriolis Sense. Demodulator Y-RATE OUT YAGC R LPY C LPy ±10% EEPROM TRIM.
FEATURES Integrated X- and Y-axis gyro on a single chip Factory trimmed full scale range of ±500 /sec Integrated low-pass filters High vibration rejection over a wide frequency range High cross-axis isolation
More informationTKR Protoflight Dynamic Test Readiness Review
TKR Protoflight Dynamic Test Readiness Review Mike Opie Mike Opie Eric Roulo Eric Roulo mikeopie@slac.stanford.edu mikeopie@slac.stanford.edu eroulo@slac.stanford.edu eroulo@slac.stanford.edu LAT-TD-05386
More informationSETUP I: CORD. Continuous Systems
Lab #8 Continuous Systems Name: Date: Section / Group: SETUP I: CORD This part of the laboratory is mainly exploratory in nature. By using your hand to force the cord close to one of its ends, you should
More informationIMU60 Inertial Measurement Unit
Precision 6 DoF MEMS Inertial Measurement Unit Range: acc ±2g, gyro ±300 /s, (ODM supported) Acc Bias Instability: ±70mg, Gyro Bias Instability: 24 /h Data Update Rate: 100Hz Wide Input Power Range: 5~18VDC
More informationMAE334 - Introduction to Instrumentation and Computers. Final Exam. December 11, 2006
MAE334 - Introduction to Instrumentation and Computers Final Exam December 11, 2006 o Closed Book and Notes o No Calculators 1. Fill in your name on side 2 of the scoring sheet (Last name first!) 2. Fill
More informationResonant MEMS Acoustic Switch Package with Integral Tuning Helmholtz Cavity
Resonant MEMS Acoustic Switch Package with Integral Tuning Helmholtz Cavity J. Bernstein, M. Bancu, D. Gauthier, M. Hansberry, J. LeBlanc, O. Rappoli, M. Tomaino-Iannucci, M. Weinberg May 1, 2018 Outline
More informationsin(wt) y(t) Exciter Vibrating armature ENME599 1
ENME599 1 LAB #3: Kinematic Excitation (Forced Vibration) of a SDOF system Students must read the laboratory instruction manual prior to the lab session. The lab report must be submitted in the beginning
More informationRecent Innovations in MEMS Sensors for PNT Applications
Recent Innovations in MEMS Sensors for PNT Applications Stanford PNT Symposium 2017 Alissa M. Fitzgerald, Ph.D. Founder & CEO amf@amfitzgerald.com Overview Navigation Developments in MEMS gyroscope technology
More informationMethods to predict fatigue in CubeSat structures and mechanisms
Methods to predict fatigue in CubeSat structures and mechanisms By Walter Holemans (PSC), Floyd Azure (PSC) and Ryan Hevner (PSC) 08-09 August 2015 12th Annual Summer CubeSat Developers' Workshop 08-09
More informationCHAPTER 6 INTRODUCTION TO SYSTEM IDENTIFICATION
CHAPTER 6 INTRODUCTION TO SYSTEM IDENTIFICATION Broadly speaking, system identification is the art and science of using measurements obtained from a system to characterize the system. The characterization
More informationModel CAACS Commercial Automated Accelerometer Calibration System
Commercial Automated Accelerometer Calibration System Features > Vibration calibration 0.5 Hz to 40 khz > Shock calibration 20 g to 10,000 g > Calibration of different type of transducers, PE, IEPE, PR,
More informationDepartment of Mechanical and Aerospace Engineering. MAE334 - Introduction to Instrumentation and Computers. Final Examination.
Name: Number: Department of Mechanical and Aerospace Engineering MAE334 - Introduction to Instrumentation and Computers Final Examination December 12, 2002 Closed Book and Notes 1. Be sure to fill in your
More informationMicro-Technology for Positioning, Navigation and Timing
Micro-Technology for Positioning, Navigation and Timing (µpnt) Dr. Program Manager DARPA/MTO Aggregation Overall goal: Enable self-contained chip-scale inertial navigation Reduce SWaP of existing Inertial
More informationIntegrated Dual-Axis Gyro IDG-1004
Integrated Dual-Axis Gyro NOT RECOMMENDED FOR NEW DESIGNS. PLEASE REFER TO THE IDG-25 FOR A FUTIONALLY- UPGRADED PRODUCT APPLICATIONS GPS Navigation Devices Robotics Electronic Toys Platform Stabilization
More informationDo all accelerometers behave the same? Meggitt-Endevco, Anthony Chu
Do all accelerometers behave the same? Meggitt-Endevco, Anthony Chu A leader in design and manufacturing of accelerometers & pressure transducers, Meggitt Endevco strives to deliver product innovations
More informationChapter 3, Sections Electrical Filters
Chapter 3, Sections 3.2.4-3.2.5 Electrical Filters Signals DC and AC Components - Many signals can be constructed as sums of AC and DC components: 2.5 2 1.5 2 1.5 1.5 1 2 3 4 1.5 -.5-1 1 2 3 4 = + 2.5
More informationSmartSenseCom Introduces Next Generation Seismic Sensor Systems
SmartSenseCom Introduces Next Generation Seismic Sensor Systems Summary: SmartSenseCom, Inc. (SSC) has introduced the next generation in seismic sensing technology. SSC s systems use a unique optical sensing
More informationMicro-nanosystems for electrical metrology and precision instrumentation
Micro-nanosystems for electrical metrology and precision instrumentation A. Bounouh 1, F. Blard 1,2, H. Camon 2, D. Bélières 1, F. Ziadé 1 1 LNE 29 avenue Roger Hennequin, 78197 Trappes, France, alexandre.bounouh@lne.fr
More informationStudy of MEMS Devices for Space Applications ~Study Status and Subject of RF-MEMS~
Study of MEMS Devices for Space Applications ~Study Status and Subject of RF-MEMS~ The 26 th Microelectronics Workshop October, 2013 Maya Kato Electronic Devices and Materials Group Japan Aerospace Exploration
More information3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn
3D Optical Motion Analysis of Micro Systems Heinrich Steger, Polytec GmbH, Waldbronn SEMICON Europe 2012 Outline Needs and Challenges of measuring Micro Structure and MEMS Tools and Applications for optical
More informationA SIMPLE FORCE BALANCE ACCELEROMETER/SEISMOMETER BASED ON A TUNING FORK DISPLACEMENT SENSOR. D. Stuart-Watson and J. Tapson
A SIMPLE FORCE BALANCE ACCELEROMETER/SEISMOMETER BASED ON A TUNING FORK DISPLACEMENT SENSOR D. Stuart-Watson and J. Tapson Department of Electrical Engineering, University of Cape Town, Rondebosch 7701,
More informationModel CAACS Commercial Automated Accelerometer Calibration System
Commercial Automated Accelerometer Calibration System Features > Vibration calibration 0.5 Hz to 40 khz > Shock calibration 20 g to 10,000 g > Calibration of different type of transducers, PE, IEPE, PR,
More informationIntegrated Dual-Axis Gyro IDG-1215
Integrated Dual-Axis Gyro FEATURES Integrated X- and Y-axis gyros on a single chip ±67 /s full-scale range 15m/ /s sensitivity Integrated amplifiers and low-pass filter Auto Zero function Integrated reset
More informationASR-2300 Multichannel SDR Module for PNT and Mobile communications. Dr. Michael B. Mathews Loctronix, Corporation
ASR-2300 Multichannel SDR Module for PNT and Mobile communications GNU Radio Conference 2013 October 1, 2013 Boston, Massachusetts Dr. Michael B. Mathews Loctronix, Corporation Loctronix Corporation 2008,
More informationOS3D-FG MINIATURE ATTITUDE & HEADING REFERENCE SYSTEM MINIATURE 3D ORIENTATION SENSOR OS3D-P. Datasheet Rev OS3D-FG Datasheet rev. 2.
OS3D-FG OS3D-FG MINIATURE ATTITUDE & HEADING REFERENCE SYSTEM MINIATURE 3D ORIENTATION SENSOR OS3D-P Datasheet Rev. 2.0 1 The Inertial Labs OS3D-FG is a multi-purpose miniature 3D orientation sensor Attitude
More informationAnthony Chu. Basic Accelerometer types There are two classes of accelerometer in general: AC-response DC-response
Engineer s Circle Choosing the Right Type of Accelerometers Anthony Chu As with most engineering activities, choosing the right tool may have serious implications on the measurement results. The information
More informationMemo. 1 Summary. 1.1 Introduction. 1.2 Experiments. 1.3 Conclusion
Topic: Tested: Date: Author: High frequency oscillations measured with high bandwidth current sensors at low current Pearson 2878 and SDN-414 shunts with different resistance values 2014 April 11 th Martin
More informationEnhanced Resonant Inspection Using Component Weight Compensation. Richard W. Bono and Gail R. Stultz The Modal Shop, Inc. Cincinnati, OH 45241
Enhanced Resonant Inspection Using Component Weight Compensation Richard W. Bono and Gail R. Stultz The Modal Shop, Inc. Cincinnati, OH 45241 ABSTRACT Resonant Inspection is commonly used for quality assurance
More informationAn Acoustic Transformer Powered Super-High Isolation Amplifier
An Acoustic Transformer Powered Super-High Isolation Amplifier A number of measurements require an amplifier whose input terminals are galvanically isolated from its output and power terminals. Such devices,
More informationCooperative navigation (part II)
Cooperative navigation (part II) An example using foot-mounted INS and UWB-transceivers Jouni Rantakokko Aim Increased accuracy during long-term operations in GNSS-challenged environments for - First responders
More informationPYKC 7 Feb 2019 EA2.3 Electronics 2 Lecture 13-1
In this lecture, we will look back on all the materials we have covered to date. Instead of going through previous lecture materials, I will focus on what you have learned in the laboratory sessions, going
More informationGlenn G. Daves. Director, Packaging Solutions Development Freescale Semiconductor, Inc.
Glenn G. Daves Director, Packaging Solutions Development Freescale Semiconductor, Inc. Freescale, the Freescale logo, AltiVec, C-5, CodeTEST, CodeWarrior, ColdFire, C-Ware, t he Energy Efficient Solutions
More informationBMC s heritage deformable mirror technology that uses hysteresis free electrostatic
Optical Modulator Technical Whitepaper MEMS Optical Modulator Technology Overview The BMC MEMS Optical Modulator, shown in Figure 1, was designed for use in free space optical communication systems. The
More informationFatigue testing. Fatigue design
Fatigue testing Lecture at SP Technical Research Institute of Sweden April 14, 2008 Gunnar Kjell SP Building Technology and Mechanics E-mail: gunnar.kjell@sp.se Fatigue design Need for material data (Distribution
More informationELECTRICAL PROPERTIES AND POWER CONSIDERATIONS OF A PIEZOELECTRIC ACTUATOR
ELECTRICAL PROPERTIES AND POWER CONSIDERATIONS OF A PIEZOELECTRIC ACTUATOR T. Jordan*, Z. Ounaies**, J. Tripp*, and P. Tcheng* * NASA-Langley Research Center, Hampton, VA 23681, USA ** ICASE, NASA-Langley
More informationHigh Performance Advanced MEMS Industrial & Tactical Grade Inertial Measurement Units
High Performance Advanced MEMS Industrial & Tactical Grade Inertial Measurement Units ITAR-free Small size, low weight, low cost 1 deg/hr Gyro Bias in-run stability Datasheet Rev.2.0 5 μg Accelerometers
More informationSimple Methods for Detecting Zero Crossing
Proceedings of The 29 th Annual Conference of the IEEE Industrial Electronics Society Paper # 000291 1 Simple Methods for Detecting Zero Crossing R.W. Wall, Senior Member, IEEE Abstract Affects of noise,
More informationMicroelectronic sensors for impedance measurements and analysis
Microelectronic sensors for impedance measurements and analysis Ph.D in Electronics, Computer Science and Telecommunications Ph.D Student: Roberto Cardu Ph.D Tutor: Prof. Roberto Guerrieri Summary 3D integration
More informationLINEAR MODELING OF A SELF-OSCILLATING PWM CONTROL LOOP
Carl Sawtell June 2012 LINEAR MODELING OF A SELF-OSCILLATING PWM CONTROL LOOP There are well established methods of creating linearized versions of PWM control loops to analyze stability and to create
More informationMEAS Silicon MEMS Piezoresistive Accelerometer and its Benefits
MEAS Silicon MEMS Piezoresistive Accelerometer and its Benefits Piezoresistive Accelerometers 1. Bonded Strain Gage type (Gages bonded to metal seismic mass using epoxy) Undamped circa 1950 s Fluid (oil)
More informationRobotic Vehicle Design
Robotic Vehicle Design Sensors, measurements and interfacing Jim Keller July 19, 2005 Sensor Design Types Topology in system Specifications/Considerations for Selection Placement Estimators Summary Sensor
More information(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine
A description is given of one way to implement an earthquake test where the test severities are specified by the sine-beat method. The test is done by using a biaxial computer aided servohydraulic test
More informationResponse spectrum Time history Power Spectral Density, PSD
A description is given of one way to implement an earthquake test where the test severities are specified by time histories. The test is done by using a biaxial computer aided servohydraulic test rig.
More informationDigitally Tuned Low Power Gyroscope
Digitally Tuned Low Power Gyroscope Bernhard E. Boser & Chinwuba Ezekwe Berkeley Sensor & Actuator Center Dept. of Electrical Engineering and Computer Sciences University of California, Berkeley B. Boser
More informationELECTROMAGNETIC MULTIFUNCTIONAL STAND FOR MEMS APPLICATIONS
ELECTROMAGNETIC MULTIFUNCTIONAL STAND FOR MEMS APPLICATIONS 1 Cristian Necula, Gh. Gheorghe, 3 Viorel Gheorghe, 4 Daniel C. Comeaga, 5 Octavian Dontu 1,,3,4,5 Splaiul Independenței 313, Bucharest 06004,
More informationTECHNICAL BULLETIN 004a Ferroresonance
May 29, 2002 TECHNICAL BULLETIN 004a Ferroresonance Abstract - This paper describes the phenomenon of ferroresonance, the conditions under which it may appear in electric power systems, and some techniques
More informationCDS 101/110a: Lecture 8-1 Frequency Domain Design
CDS 11/11a: Lecture 8-1 Frequency Domain Design Richard M. Murray 17 November 28 Goals: Describe canonical control design problem and standard performance measures Show how to use loop shaping to achieve
More informationAudio System Evaluation with Music Signals
Audio System Evaluation with Music Signals Stefan Irrgang, Wolfgang Klippel GmbH Audio System Evaluation with Music Signals, 1 Motivation Field rejects are $$$ Reproduce + analyse the problem before repair
More informationActive Vibration Isolation of an Unbalanced Machine Tool Spindle
Active Vibration Isolation of an Unbalanced Machine Tool Spindle David. J. Hopkins, Paul Geraghty Lawrence Livermore National Laboratory 7000 East Ave, MS/L-792, Livermore, CA. 94550 Abstract Proper configurations
More informationECE 6770 FINAL PROJECT
ECE 6770 FINAL PROJECT POINT TO POINT COMMUNICATION SYSTEM Submitted By: Omkar Iyer (Omkar_iyer82@yahoo.com) Vamsi K. Mudarapu (m_vamsi_krishna@yahoo.com) MOTIVATION Often in the real world we have situations
More informationThe Series RLC Circuit and Resonance
Purpose Theory The Series RLC Circuit and Resonance a. To study the behavior of a series RLC circuit in an AC current. b. To measure the values of the L and C using the impedance method. c. To study the
More informationThe Fundamentals of Mixed Signal Testing
The Fundamentals of Mixed Signal Testing Course Information The Fundamentals of Mixed Signal Testing course is designed to provide the foundation of knowledge that is required for testing modern mixed
More informationFLCS V2.1. AHRS, Autopilot, Gyro Stabilized Gimbals Control, Ground Control Station
AHRS, Autopilot, Gyro Stabilized Gimbals Control, Ground Control Station The platform provides a high performance basis for electromechanical system control. Originally designed for autonomous aerial vehicle
More informationEE4902 C Lab 7
EE4902 C2007 - Lab 7 MOSFET Differential Amplifier Resistive Load Active Load PURPOSE: The primary purpose of this lab is to measure the performance of the differential amplifier. This is an important
More informationCore Technology Group Application Note 6 AN-6
Characterization of an RLC Low pass Filter John F. Iannuzzi Introduction Inductor-capacitor low pass filters are utilized in systems such as audio amplifiers, speaker crossover circuits and switching power
More informationAn Improved Analytical Model for Efficiency Estimation in Design Optimization Studies of a Refrigerator Compressor
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2014 An Improved Analytical Model for Efficiency Estimation in Design Optimization Studies
More informationHigh voltage amplifiers: how fast are they really? Falco Systems application note, version 2.0,
Application note High voltage amplifiers: how fast are they really? Falco Systems application note, version., www.falco-systems.com W. Merlijn van Spengen, PhD March 1 The high speed, high voltage amplifier:
More informationChapter 8: Field Effect Transistors
Chapter 8: Field Effect Transistors Transistors are different from the basic electronic elements in that they have three terminals. Consequently, we need more parameters to describe their behavior than
More informationAn internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.
TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant
More informationLAB INSTRUMENTATION. RC CIRCUITS.
LAB INSTRUMENTATION. RC CIRCUITS. I. OBJECTIVE a) Becoming accustomed to using the lab instrumentation (voltage supply, digital multimeter, signal generator, oscilloscope) necessary to the experimental
More informationIntroduction to LIVM Accelerometers
Introduction to LIVM Accelerometers Construction Low Impedance Voltage Mode (LIVM) accelerometers are designed to measure shock and vibration phenomena over a wide frequency range. They contain integral
More informationIntroduction. ELCT903, Sensor Technology Electronics and Electrical Engineering Department 1. Dr.-Eng. Hisham El-Sherif
Introduction In automation industry every mechatronic system has some sensors to measure the status of the process variables. The analogy between the human controlled system and a computer controlled system
More informationSensitivity of frequency response to type of tubing
1. Introduction Sensitivity of frequency response to type of tubing A.W. Rofail, R. Tonin and D. Hanafi Windtech Consultants Pty Ltd, Sydney Windtech Consultants uses measurements of the frequency response
More informationPHYS 536 The Golden Rules of Op Amps. Characteristics of an Ideal Op Amp
PHYS 536 The Golden Rules of Op Amps Introduction The purpose of this experiment is to illustrate the golden rules of negative feedback for a variety of circuits. These concepts permit you to create and
More informationInstrumentation (ch. 4 in Lecture notes)
TMR7 Experimental methods in Marine Hydrodynamics week 35 Instrumentation (ch. 4 in Lecture notes) Measurement systems short introduction Measurement using strain gauges Calibration Data acquisition Different
More informationThis manuscript was the basis for the article A Refresher Course in Control Theory printed in Machine Design, September 9, 1999.
This manuscript was the basis for the article A Refresher Course in Control Theory printed in Machine Design, September 9, 1999. Use Control Theory to Improve Servo Performance George Ellis Introduction
More informationDynamic Vibration Absorber
Part 1B Experimental Engineering Integrated Coursework Location: DPO Experiment A1 (Short) Dynamic Vibration Absorber Please bring your mechanics data book and your results from first year experiment 7
More informationRobotic Vehicle Design
Robotic Vehicle Design Sensors, measurements and interfacing Jim Keller July 2008 1of 14 Sensor Design Types Topology in system Specifications/Considerations for Selection Placement Estimators Summary
More informationImpedance Measurements Using TEF
Using the SLX module of SoundLab for TEF is an excellent way to measure the input impedance of a loudspeaker. There are two methods whereby one may make this measurement. The first is by driving the DUT
More information15-8 1/31/2014 PRELAB PROBLEMS 1. Why is the boundary condition of the cavity such that the component of the air displacement χ perpendicular to a wall must vanish at the wall? 2. Show that equation (5)
More informationDepartment of Electrical and Computer Engineering. Laboratory Experiment 1. Function Generator and Oscilloscope
Department of Electrical and Computer Engineering Laboratory Experiment 1 Function Generator and Oscilloscope The purpose of this first laboratory assignment is to acquaint you with the function generator
More informationAdvances in Silicon Technology Enables Replacement of Quartz-Based Oscillators
Advances in Silicon Technology Enables Replacement of Quartz-Based Oscillators I. Introduction With a market size estimated at more than $650M and more than 1.4B crystal oscillators supplied annually [1],
More informationCapacitive Sensing Project. Design of A Fully Differential Capacitive Sensing Circuit for MEMS Accelerometers. Matan Nurick Radai Rosenblat
Capacitive Sensing Project Design of A Fully Differential Capacitive Sensing Circuit for MEMS Accelerometers Matan Nurick Radai Rosenblat Supervisor: Dr. Claudio Jacobson VLSI Laboratory, Technion, Israel,
More informationGround vibration testing: Applying structural analysis with imc products and solutions
Ground vibration testing: Applying structural analysis with imc products and solutions Just as almost any mechanical structure, aircraft body parts or complete aircrafts can be modelled precisely and realistically
More informationOscilloscope and Function Generators
MEHRAN UNIVERSITY OF ENGINEERING AND TECHNOLOGY, JAMSHORO DEPARTMENT OF ELECTRONIC ENGINEERING ELECTRONIC WORKSHOP # 02 Oscilloscope and Function Generators Roll. No: Checked by: Date: Grade: Object: To
More informationSurface Micromachining
Surface Micromachining An IC-Compatible Sensor Technology Bernhard E. Boser Berkeley Sensor & Actuator Center Dept. of Electrical Engineering and Computer Sciences University of California, Berkeley Sensor
More informationOptimizing Automatic Parametric Test (APT) in Mixed Signal / Mems foundry
Optimizing Automatic Parametric Test (APT) in Mixed Signal / Mems foundry Authors: Steffen Richter, Group Mgr PCM-Member Technical Staff, Xfab Silicon Foundries Alex Pronin, Ph.D, Lead Applications Engineer,
More informationMATHEMATICAL MODEL VALIDATION
CHAPTER 5: VALIDATION OF MATHEMATICAL MODEL 5-1 MATHEMATICAL MODEL VALIDATION 5.1 Preamble 5-2 5.2 Basic strut model validation 5-2 5.2.1 Passive characteristics 5-3 5.2.2 Workspace tests 5-3 5.3 SDOF
More informationLab 2: Capacitors. Integrator and Differentiator Circuits
Lab 2: Capacitors Topics: Differentiator Integrator Low-Pass Filter High-Pass Filter Band-Pass Filter Integrator and Differentiator Circuits The simple RC circuits that you built in a previous section
More informationMEMS for Geophysicists
MEMS for Geophysicists Jon Tessman, Bruce Reichert, Jim Marsh, Jeff Gannon, Howard Goldberg Input / Output Inc., Stafford, Texas, USA Summary Input/Output, Inc. has developed a MEMS accelerometer to use
More informationDigital Logic, Algorithms, and Functions for the CEBAF Upgrade LLRF System Hai Dong, Curt Hovater, John Musson, and Tomasz Plawski
Digital Logic, Algorithms, and Functions for the CEBAF Upgrade LLRF System Hai Dong, Curt Hovater, John Musson, and Tomasz Plawski Introduction: The CEBAF upgrade Low Level Radio Frequency (LLRF) control
More informationME 434 MEMS Tuning Fork Gyroscope Amanda Bristow Stephen Nary Travis Barton 12/9/10
ME 434 MEMS Tuning Fork Gyroscope Amanda Bristow Stephen Nary Travis Barton 12/9/10 1 Abstract MEMS based gyroscopes have gained in popularity for use as rotation rate sensors in commercial products like
More informationTo Calibrate or Not to Calibrate a fieldbus transmitter? Dale Perry Pressure Marketing Manager Rosemount
To Calibrate or Not to Calibrate a fieldbus transmitter? Dale Perry Pressure Marketing Manager Rosemount Introduction Digital Transmitters are here Wireless Fieldbus Same architecture as Smart-HART transmitter
More informationPulsed VNA Measurements:
Pulsed VNA Measurements: The Need to Null! January 21, 2004 presented by: Loren Betts Copyright 2004 Agilent Technologies, Inc. Agenda Pulsed RF Devices Pulsed Signal Domains VNA Spectral Nulling Measurement
More informationCHOOSING THE RIGHT TYPE OF ACCELEROMETER
As with most engineering activities, choosing the right tool may have serious implications on the measurement results. The information below may help the readers make the proper accelerometer selection.
More informationEE 42/100: Lecture 8. 1 st -Order RC Transient Example, Introduction to 2 nd -Order Transients. EE 42/100 Summer 2012, UC Berkeley T.
EE 42/100: Lecture 8 1 st -Order RC Transient Example, Introduction to 2 nd -Order Transients Circuits with non-dc Sources Recall that the solution to our ODEs is Particular solution is constant for DC
More information