EE POWER ELECTRONICS UNIT IV INVERTERS

Size: px
Start display at page:

Download "EE POWER ELECTRONICS UNIT IV INVERTERS"

Transcription

1 EE POWER ELECTRONICS UNIT IV INVERTERS PART- A 1. Define harmonic distortion factor? (N/D15) Harmonic distortion factor is the harmonic voltage to the fundamental voltage. 2. What is CSI? (N/D12) In Current Source Inverter, the current is nearly constant. The voltage changes with respect the the load change. 3. What are the difference between VSI and CSI? (M/J12) (M/J16) VSI CSI Uses voltage source. Uses current commutation. Diodes are connected in parallel. Uses current source. Uses voltage commutation Diodes are connected in series. Can be used for only 1208 and 1808 Can be used for only 1208 Output voltage is quasi square wave. Output current is quasi square wave. 4. What is the necessity of PWM within an inverter? (N/D12) To control voltage and harmonics PWM is used. In PWM, output voltage is controlled by varying the width of pulse. Percentage harmonic can be controlled by changing number of pulse per half cycle. 5. Define the term inverter gain. (M/J12) Inverter gain is defined as the ratio of output voltage to the input voltage of an inverter. 7. What is harmonic elimination by PWM? (M/J15) Pulse width modulation is used to eliminate harmonics by comparing reference signal and carrier signal and when reference signal is greater than carrier signal triggering pulses are generated for switches in the inverter. 8. In a CSI, if frequency of output voltage is f Hz, what is the frequency of voltage input to CSI? (M/J13) The input frequency is 50Hz. 9. What is Space Vector? (M/J13) Space vector modulation (SVM) is an algorithm for the control of pulse width modulation (PWM). It is used for the creation of alternating current (AC) waveforms; most commonly to drive 3 phase AC powered motors at varying speeds from DC using multipleclass-d amplifiers. There are various variations of SVM that result in different quality and computational requirements. 10. What is the advantages of 120 degree conduction mode of inverter over 180 degree conduction mode? (N/D13) In 120ᵒ conduction mode safe commutation is obtained on complementary switches in same leg.

2 11. List the various advantages of using PWM control to inverters? (N/D13)(M/J14) PWM inverters produce high-quality sine waves. The harmonic levels are very low and can be lower than those of common domestic appliances. 12. What is meant by voltage source inverter?(dec 2014)(DEC 2015) Voltage source inverters (VSIs) are named so because the independently controlled output is a voltage waveform. Voltage Source Inverters (VSI) feed the output inverter section from an constant-voltage source. 13. Write the advantages of resonant converters?(dec 2014) Resonant converters are used to reduce/eliminate the switching losses and the output waveform is more sinusoidal. There are three basic types of the resonant DC/DC converters: 1. Series resonant converter 2. Parallel resonant converter 3. Series-Parallel resonant converter 14. Draw the circuit diagram of single phase CSI?(May 2015) 15.What are the applications of inverter? (M/J 16) The inverter is an electrical device, which is used to convert the DC power to an AC power. The inverter for home is used for emergency backup power and used in some aircraft systems to convert a portion of the aircraft DC power to AC. Inverters are used to control the speed of AC motors. 16. What are the application of CSI? (N/D16) i)it can be used for the speed control of ac, specially induction, motors subject to variation in load torque. ii)used in induction heating application. 17. Define modulation index and what its use. (N/D16) Modulation index is the ratio of peak magnitudes of the modulating waveform and the carrier waveform. M= Vm Vc Modulation index used for control the output of inverter.

3 PART-B 1. Explain the operation of series Resonant Inverter. (M/J12)(M/J14) (N/D14)

4

5 2. Explain the operation of 180 Conduction of three phase inverter. (N/D14)(M/J15)

6

7

8

9 3. Explain the operation of 120 Conduction of three phase inverter. Also obtain the epression for rms value of output voltage (N/D12) (M/J13) (M/J14)(N/D15) Derive the mathematical expression. Average line voltage expression Average current expression

10 Compare with 180 degree mode States advantages of 120 degree mode States disadvantages of 120 degree mode Explain the working principle Explain the different mode of operation Output waveform of 3 phase inveter in 120 degree conduction mode

11 4. Explain different PWM techniques. (N/D12) (M/J12) (M/J14)(N/D15) Multi-Pulse width modulation The harmonic content can be reduced by using several pulses in each half-cycle of output voltage. The generation of gating signals for turning on and off transistors is shown in Figure (3). The gating signals are produced by comparing reference signal with triangular carrier wave. The frequency of the reference signal sets the output frequency (fo) and carrier frequency (fc) determine the number of pulses per half cycle, The variation of modulation index (M) from 0 to 1 varies the pulse from 0 to π/p and the output voltage from 0 to Vm. Uniform pulse width modulation (UPWM) Figure (1) shows the uniform pulse width modulation (UPWM). It can be note the reference voltage is square wave changed from the Vm to Vm in frequency = fo. The carrier frequency is triangle wave with amplitude equal to Vc in frequency = fc. Sinusoidal Pulse Width modulation Instead of maintaining the width of all pulses the same as in the case of uniform pulse width modulation, the width of each pulse is vary in proportion to the amplitude of a sine wave evaluated at the center of the same pulse. The distortion factor and lower-order harmonics are reduced scientifically. The gating signals as shown in Fig.(2) are generated by comparing a sinusoidal reference signal with a triangular carrier signal of frequency fc. This type of modulation is commonly used in industrial applications and abbreviated as SPWM. The frequency of reference signal (fr), determine the converter output frequency (fo) and its peak amplitude (Ar) controls the modulation index, M. The number of pulses per half cycle depends on the carrier frequency.

12 5. Explain space vector pulse width modulation techniques The space vector modulation technique is somewhat similar to the Sine+3 rd harmonic PWM technique but the method of implementation is different. Before going into details of this technique, it would be useful to explore the concept of voltage space-vector, in analogy with the concept of flux space-vector as used in three-phase ac machine. The stator windings of a three-phase ac machine (with cylindrical rotor), when fed with a three-phase balanced current produce a resultant flux space-vector that rotates at synchronous speed in the space. The flux vector due to an individual phase winding is oriented along the axis of that particular winding and its magnitude alternates as the current through it is alternating. The magnitude of the resultant flux due to all three windings is, however, fixed at 1.5 times the peak magnitude due to individual phase windings. The resultant flux is commonly known as the synchronously rotating flux vector. Now, in analogy with the fluxes, if a three phase balanced voltage is applied to the windings of a three-phase machine, a rotating voltage space vector may be talked of. The resultant voltage space-vector will be rotating uniformly at the synchronous speed and will have a magnitude equal to 1.5 times the peak magnitude of the phase voltage. Fig (a) shows a set of three-phase balanced sinusoidal voltages. Let these voltages be applied to the windings of a three-phase ac machine as shown in Fig. 38.2(b). Now, during each time period of the phase voltages six discrete time instants can be identified, as done in Fig. 38.2(a), when one of the phase voltages have maximum positive or negative instantaneous magnitude. The resultants of the three space-voltages at these instants have been named V1 to V6. The spatial positions of these resultant voltage space-vectors have been shown in Fig. 38.2(b). At these six discrete instants, these vectors are aligned along the phase axes having maximum instantaneous voltage. As shown in Fig. 38.2(a) the magnitude of these voltage vectors is 1.5 times the peak magnitude of individual phase voltage. The instantaneous voltage output from a 3-phase inverter, discussed in earlier lessons, cannot be made to match the three sinusoidal phase voltages of Fig. 38.2(a) at all time instants. This is so because the inverter outputs are obtained from rectangular pole voltages and contain, apart from the fundamental, harmonic voltages too. However, the instantaneous magnitudes of the inverter outputs and the sinusoidal voltages can be made to match at the six discrete instants (talked above) of the output cycle. At these six discrete instants one of the phase

13 voltages is at its positive or negative peak magnitude and the other two have half of the peak magnitude. The polarity of the peak phase-voltage is opposite to that of the other two phasevoltages. A similar pattern is seen in the instantaneous phase voltages output by a 3-phase inverter and is explained below. Fig shows a three-phase voltage source inverter whose output terminals are fed to the three terminal of a three-phase ac machine (in fact to any three phase balanced load). Fromthe knowledge of 3-phase voltage source inverters, it may be obvious that the two switches ofeach inverter pole conduct in a complementary manner. Thus the six switches of the three poles will have a total of eight different switching combinations. Out of these eight combinations, two combinations wherein all the upper switches or all the lower switches of each pole are simultaneously ON result in zero output voltage from the inverter. These two combinations are referred as null states of the inverter. The remaining six switching combinations, wherein either two of the high side (upper) switches and one of the low side (lower) switch conduct, or vice-versa, are active states. During the six active states the phase voltages output by the inverter to a balanced 3-phase linear load are as detailed in Sec.35.1 of Lesson 35. Accordingly instantaneous magnitude of two of the phase voltages are 1/3 rd Edc and the third phase voltage is 2/3 rd Edc (where E dc is the dc link voltage). The voltage polarities of the two phases getting 1/3 rd Edcare identical and opposite to the third phase having 2/3 rd Edc. Fig also shows, in a tabular form, the instantaneous magnitudes of the three load-phase voltages (normalized by the dc link voltage magnitude) during the six active states of the inverter. The switching states of the inverter have been indicated by a 3-bit switching word. The 1 st(msb) bit for leg A, 2 nd bit for leg B and 3 rd bit for leg C. When a particular bit is 1, the high (upper) side switch of that leg is ON and when the bit is 0, the low side switch is ON. Thus a switching word 101 indicates that high side switches of legs A and C and lowside switch of leg B conduct. The resulting voltage pattern isidentical to the voltage pattern of space voltage vector V 1 of Fig provided 2/3 rd Edcequals the peak magnitude of phase voltage in Fig The table given in Fig shows how six active states of the inverter produce space voltage vectors V1 to V6 that can be identified on one to one basis with the six voltage vectors. There are some important differences between the resultant space voltage vectors due to the sinusoidal phase voltages of Fig and the space voltage vectors formed by the inverter output voltages.

14 6. Explain with waveform multiple pulse width modulation inverter(m/j15) 7. Explain the basic operation of single phase current source inverter. (M/J12) (N/D13) The circuit of a Single-phase Current Source Inverter (CSI) is shown in Fig The type of operation is termed as Auto-Sequential Commutated Inverter (ASCI). A constant current source is assumed here, which may be realized by using an inductance of suitable value, which must be high, in series with the current limited dc voltage source. The thyristor pairs, Th1 & Th3, and Th2 & Th4, are alternatively turned ON to obtain a nearly square wave current waveform. Two commutating capacitors C1 in the upper half, and C2 in the lower half, are used. Four diodes, D1 D4 are connected in series with each thyristor to prevent the commutating capacitors from discharging into the load. The output frequency of the inverter is controlled in the usual way, i.e., by varying the half time period, (T/2), at which the thyristors in pair are triggered by pulses being fed to the respective gates by the control circuit, to turn them ON, as can be observed from the waveforms (Fig. 39.2). The inductance (L) is taken as the load in this case, the reason(s) for which need not be stated, being well known. The operation is explained by two modes.

15 Mode I: The circuit for this mode is shown in Fig The following are the assumptions. Starting from the instant,, the thyristor pair, Th =0t2 & Th4, is conducting (ON), and the current (I) flows through the path, Th2, D2, load (L), D4, Th4, and source, I. The commutating capacitors are initiallycharged equally with the polarity as given, i.e.,. This mans that both capacitors have right hand plate positive and left hand plate negative. If two capacitors are not charged initially, they have to precharged. At time, t = 0, thyristor pair, Th1 & Th3, is triggered by pulses at the gates. The conducting thyristor pair, Th2 & Th4, is turned OFF by application of reverse capacitor voltages. Now, thyristor pair, Th1 & Th3, conducts current (I). The current path is through Th1, C1, D2, L, D4, C2, Th3, and source, I. Both capacitors will now begin charging linearly from () by the constant current, I. The diodes, D0CV 2 & D4, remain reverse biased initially. The voltage, across D1Dv1, when it is forwardbiased, is obtained by going through the closed path, abcda as It may be noted the voltage across load inductance, L is zero (0), as the current, I is constant. As the capacitor gets charged, the voltage across D1Dv1, increases linearly. At some time, say t1, the reverse bias across D1 becomes zero (0), the diode, D1.starts conducting. An identical equation can be formed for diode, D3also. Actually, both diodes, D1 & D3, start conducting at the same instant, t1. The time t1 for which the diodes, D1& D3, remain reverse biased is obtained.

16 At time, t = 0, thyristor pair, Th1 & Th3, is triggered by pulses at the gates. The conducting thyristor pair, Th2 & Th4, is turned OFF by application of reverse capacitor voltages. Now, thyristor pair, Th1 & Th3, conducts current (I). The current path is through Th1, C1, D2, L, D4, C2, Th3, and source, I. Both capacitors will now begin charging linearly from () by the constant current, I. The diodes, D0CV 2 &D4, remain reverse biased initially. The voltage, across D1Dv1, when it is forward biased, is obtained by going through the closed path, abcda as it may be noted the voltage across load inductance, L is zero (0), as the current, I is constant. As the capacitor gets charged, the voltage across D1Dv1 increases linearly. At some time, say t1, the reverse bias across D1becomes zero (0), the diode,d1.starts conducting. An identical equation can be formed for diode, D3also. Actually, both diodes, D1& D3, start conducting at the same instant, t1. The time t1 for which the diodes, D1 & D3, remain reverse biased is obtained by equating,. The capacitor voltages, appear as reverse voltage across the thyristors. MODE2 8. Discuss the principle of working of a three phase bridge inverter with an appropriate circuit diagram. Draw the output phase and line voltage waveforms on the assumption that each tryistor conducts for 180ᵒ and resistive load is star connected. The swquence of firing of various SCR should also be indicated. (Nov 2013) 9. Explain the basic operation of load commutated current source inverter In the last lesson, ASCI mode of operation for a single-phase Current Source Inverter (CSI) was presented. Two commutating capacitors, along with four diodes, are used in the above circuit for commutation from one pair of thyristors to the second pair. Earlier, also in VSI, if the load is capacitive, it was shown that forced commutation may not be needed. The operation of a single-phase CSI with capacitive load (Fig) is discussed here. It may be noted that the capacitor, C is assumed to be in parallel with resistive load (R). The capacitor, C is used for storing the charge, or voltage, to be used to force-commutate the conducting thyristor pair as will be shown. As was the case in the last lesson, a constant current source, or a voltage source with large inductance, is used as the input to the circuit

17 The power switching devices used here is the same, i.e. four thyristors only in a full- bridge configuration. The positive direction for load current and voltage, is shown in Fig Before t = 0, the capacitor voltage is, i.e. the capacitor has left plate negative and right plate positive. At that time, the thyristor pair, Th1VvC =2&Th4 was conducting. When (at t = 0),vthe thyristor. through load resistance, R has the same nature as that of (Fig. 40.2). Similarly, when (at), the thyristor pair, Thpair, Th1 & Th3 is triggered by the pulses fed at the gates, the conducting thyristor pair, Th2 & Th4 is reverse biased by the capacitor voltage 1VvC =, and turns off immediately. The current path is through Th1, load (parallel combination of R & C), Th3, and the source.

18 Various current and voltage waveforms during one cycle, are shown in Fig Explain multiple pulse width modulation and explain sinusoidal pulse width modulation. (June 2013) (Nov 2013) Sinusoidal Pulse width modulation The switches in the voltage source inverter (See Fig. 1)can be turned on and off as required. In the simplest approach, the top switch is turned on If turned on and off only once in each cycle, a square wave waveform results. However, if turned on several times in a cycle an improved harmonicprofile may be achieved.

19 In the most straightforward implementation, generation of the desired output voltage is achieved by comparing the desired reference waveform (modulating signal) with a highfrequency triangular carrier wave as depicted schematically in Fig.2. Depending on whether the signal voltage is larger or smaller than the carrier waveform, either the positive or negative dc bus voltage is applied at the output. Note that over the period of one triangle wave, the average voltage applied to the load is proportional to the amplitude of the signal (assumed constant) during this period. The resulting chopped square waveform contains a replica of the desired waveform in its low frequency components, with the higher frequency components being at frequencies of an close to the carrier frequency. Notice that the root mean square value of the ac voltage waveform is still equal to the dc bus voltage, and hence the total harmonic distortion is not affected by the PWM process. The harmonic components are merely shifted into the higher frequency range and are automatically filtered due to inductances in the ac system. When the modulating signal is a sinusoid of amplitude Am, and the amplitude of the triangular carrier is Ac, the ratio m=am/ac is known as the modulation index. Note that controlling the modulation index there for controls the amplitude of the applied output voltage. With a sufficiently high carrier frequency (see Fig. 3 drawn for fc/fm = 21 and t = L/R = T/3; T = period of fundamental), the high frequency components do not propagate significantly in the ac network (or load)due the presence of the inductive elements. However, a higher carrier frequency does result in a larger number of switching s per cycle and hence in an increased power loss. Typically switching frequencies in the 2-15 khz range are considered adequate for power systems applications. Also in three-phase systems it is advisable to use so that all three waveforms are symmetric.

Module 5. DC to AC Converters. Version 2 EE IIT, Kharagpur 1

Module 5. DC to AC Converters. Version 2 EE IIT, Kharagpur 1 Module 5 DC to AC Converters Version 2 EE IIT, Kharagpur 1 Lesson 38 Other Popular PWM Techniques Version 2 EE IIT, Kharagpur 2 After completion of this lesson, the reader shall be able to: 1. Explain

More information

CHAPTER IV DESIGN AND ANALYSIS OF VARIOUS PWM TECHNIQUES FOR BUCK BOOST CONVERTER

CHAPTER IV DESIGN AND ANALYSIS OF VARIOUS PWM TECHNIQUES FOR BUCK BOOST CONVERTER 59 CHAPTER IV DESIGN AND ANALYSIS OF VARIOUS PWM TECHNIQUES FOR BUCK BOOST CONVERTER 4.1 Conventional Method A buck-boost converter circuit is a combination of the buck converter topology and a boost converter

More information

13. DC to AC Converters

13. DC to AC Converters 13. DC to AC Converters Inverters Inverter is a device which converts DC voltages (or current) to AC voltages (or current).inverter converting voltage is called VOLTAGE SOURCE INVERTER (VSI), while inverter

More information

Module 5. DC to AC Converters. Version 2 EE IIT, Kharagpur 1

Module 5. DC to AC Converters. Version 2 EE IIT, Kharagpur 1 Module 5 DC to AC Converters Version 2 EE IIT, Kharagpur 1 Lesson 37 Sine PWM and its Realization Version 2 EE IIT, Kharagpur 2 After completion of this lesson, the reader shall be able to: 1. Explain

More information

Implementation Full Bridge Series Resonant Buck Boost Inverter

Implementation Full Bridge Series Resonant Buck Boost Inverter Implementation Full Bridge Series Resonant Buck Boost Inverter A.Srilatha Assoc.prof Joginpally College of engineering,hyderabad pradeep Rao.J Asst.prof Oxford college of Engineering,Bangalore Abstract:

More information

Lecture Note. DC-AC PWM Inverters. Prepared by Dr. Oday A Ahmed Website: https://odayahmeduot.wordpress.com

Lecture Note. DC-AC PWM Inverters. Prepared by Dr. Oday A Ahmed Website: https://odayahmeduot.wordpress.com Lecture Note 10 DC-AC PWM Inverters Prepared by Dr. Oday A Ahmed Website: https://odayahmeduot.wordpress.com Email: 30205@uotechnology.edu.iq Scan QR DC-AC PWM Inverters Inverters are AC converters used

More information

CHAPTER 3 SINGLE SOURCE MULTILEVEL INVERTER

CHAPTER 3 SINGLE SOURCE MULTILEVEL INVERTER 42 CHAPTER 3 SINGLE SOURCE MULTILEVEL INVERTER 3.1 INTRODUCTION The concept of multilevel inverter control has opened a new avenue that induction motors can be controlled to achieve dynamic performance

More information

Pulse width modulated (PWM) inverters are mostly used power electronic circuits in

Pulse width modulated (PWM) inverters are mostly used power electronic circuits in 2.1 Introduction Pulse width modulated (PWM) inverters are mostly used power electronic circuits in practical applications. These inverters are able to produce ac voltages of variable magnitude and frequency.

More information

CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL

CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL 9 CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL 2.1 INTRODUCTION AC drives are mainly classified into direct and indirect converter drives. In direct converters (cycloconverters), the AC power is fed

More information

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE 58 CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE 4.1 INTRODUCTION Conventional voltage source inverter requires high switching frequency PWM technique to obtain a quality output

More information

Module 7. Electrical Machine Drives. Version 2 EE IIT, Kharagpur 1

Module 7. Electrical Machine Drives. Version 2 EE IIT, Kharagpur 1 Module 7 Electrical Machine Drives Version 2 EE IIT, Kharagpur 1 Lesson 34 Electrical Actuators: Induction Motor Drives Version 2 EE IIT, Kharagpur 2 Instructional Objectives After learning the lesson

More information

Lecture 19 - Single-phase square-wave inverter

Lecture 19 - Single-phase square-wave inverter Lecture 19 - Single-phase square-wave inverter 1. Introduction Inverter circuits supply AC voltage or current to a load from a DC supply. A DC source, often obtained from an AC-DC rectifier, is converted

More information

Nicolò Antonante Kristian Bergaplass Mumba Collins

Nicolò Antonante Kristian Bergaplass Mumba Collins Norwegian University of Science and Technology TET4190 Power Electronics for Renewable Energy Mini-project 19 Power Electronics in Motor Drive Application Nicolò Antonante Kristian Bergaplass Mumba Collins

More information

DOWNLOAD PDF POWER ELECTRONICS DEVICES DRIVERS AND APPLICATIONS

DOWNLOAD PDF POWER ELECTRONICS DEVICES DRIVERS AND APPLICATIONS Chapter 1 : Power Electronics Devices, Drivers, Applications, and Passive theinnatdunvilla.com - Google D Download Power Electronics: Devices, Drivers and Applications By B.W. Williams - Provides a wide

More information

Module 5. DC to AC Converters. Version 2 EE IIT, Kharagpur 1

Module 5. DC to AC Converters. Version 2 EE IIT, Kharagpur 1 Module 5 DC to AC Converters Version EE II, Kharagpur 1 Lesson 34 Analysis of 1-Phase, Square - Wave Voltage Source Inverter Version EE II, Kharagpur After completion of this lesson the reader will be

More information

14. DC to AC Converters

14. DC to AC Converters 14. DC to AC Converters Single-phase inverters: 14.1 Single-phase half-bridge inverter This type of inverter is very simple in construction. It does not need output transformer like parallel inverter.

More information

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING Power Diode EE2301 POWER ELECTRONICS UNIT I POWER SEMICONDUCTOR DEVICES PART A 1. What is meant by fast recovery

More information

Dr.Arkan A.Hussein Power Electronics Fourth Class. 3-Phase Voltage Source Inverter With Square Wave Output

Dr.Arkan A.Hussein Power Electronics Fourth Class. 3-Phase Voltage Source Inverter With Square Wave Output 3-Phase Voltage Source Inverter With Square Wave Output ١ fter completion of this lesson the reader will be able to: (i) (ii) (iii) (iv) Explain the operating principle of a three-phase square wave inverter.

More information

( ) ON s inductance of 10 mh. The motor draws an average current of 20A at a constant back emf of 80 V, under steady state.

( ) ON s inductance of 10 mh. The motor draws an average current of 20A at a constant back emf of 80 V, under steady state. 1991 1.12 The operating state that distinguishes a silicon controlled rectifier (SCR) from a diode is (a) forward conduction state (b) forward blocking state (c) reverse conduction state (d) reverse blocking

More information

A Switched Boost Inverter Fed Three Phase Induction Motor Drive

A Switched Boost Inverter Fed Three Phase Induction Motor Drive A Switched Boost Inverter Fed Three Phase Induction Motor Drive 1 Riya Elizabeth Jose, 2 Maheswaran K. 1 P.G. student, 2 Assistant Professor 1 Department of Electrical and Electronics engineering, 1 Nehru

More information

Module 4. AC to AC Voltage Converters. Version 2 EE IIT, Kharagpur 1

Module 4. AC to AC Voltage Converters. Version 2 EE IIT, Kharagpur 1 Module 4 AC to AC Voltage Converters Version EE IIT, Kharagpur 1 Lesson 9 Introduction to Cycloconverters Version EE IIT, Kharagpur Instructional Objectives Study of the following: The cyclo-converter

More information

International Journal of Advance Engineering and Research Development

International Journal of Advance Engineering and Research Development Scientific Journal of Impact Factor (SJIF): 4.14 International Journal of Advance Engineering and Research Development Volume 3, Issue 10, October -2016 e-issn (O): 2348-4470 p-issn (P): 2348-6406 Single

More information

Modeling and Simulation of Five Phase Induction Motor Fed with Five Phase Inverter Topologies

Modeling and Simulation of Five Phase Induction Motor Fed with Five Phase Inverter Topologies Indian Journal of Science and Technology, Vol 8(19), DOI: 1.17485/ijst/215/v8i19/7129, August 215 ISSN (Print) : 974-6846 ISSN (Online) : 974-5645 Modeling and Simulation of Five Phase Induction Motor

More information

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE 98 CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE 6.1 INTRODUCTION Process industries use wide range of variable speed motor drives, air conditioning plants, uninterrupted power supply systems

More information

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE 3.1 STATOR VOLTAGE CONTROL The induction motor 'speed can be controlled by varying the stator voltage. This method of speed control is known as stator

More information

A Novel Four Switch Three Phase Inverter Controlled by Different Modulation Techniques A Comparison

A Novel Four Switch Three Phase Inverter Controlled by Different Modulation Techniques A Comparison Volume 2, Issue 1, January-March, 2014, pp. 14-23, IASTER 2014 www.iaster.com, Online: 2347-5439, Print: 2348-0025 ABSTRACT A Novel Four Switch Three Phase Inverter Controlled by Different Modulation Techniques

More information

11. Define the term pinch off voltage of MOSFET. (May/June 2012)

11. Define the term pinch off voltage of MOSFET. (May/June 2012) Subject Code : EE6503 Branch : EEE Subject Name : Power Electronics Year/Sem. : III /V Unit - I PART-A 1. State the advantages of IGBT over MOSFET. (Nov/Dec 2008) 2. What is the function of snubber circuit?

More information

CHAPTER-III MODELING AND IMPLEMENTATION OF PMBLDC MOTOR DRIVE

CHAPTER-III MODELING AND IMPLEMENTATION OF PMBLDC MOTOR DRIVE CHAPTER-III MODELING AND IMPLEMENTATION OF PMBLDC MOTOR DRIVE 3.1 GENERAL The PMBLDC motors used in low power applications (up to 5kW) are fed from a single-phase AC source through a diode bridge rectifier

More information

Type of loads Active load torque: - Passive load torque :-

Type of loads Active load torque: - Passive load torque :- Type of loads Active load torque: - Active torques continues to act in the same direction irrespective of the direction of the drive. e.g. gravitational force or deformation in elastic bodies. Passive

More information

ELECTRONIC CONTROL OF A.C. MOTORS

ELECTRONIC CONTROL OF A.C. MOTORS CONTENTS C H A P T E R46 Learning Objectives es Classes of Electronic AC Drives Variable Frequency Speed Control of a SCIM Variable Voltage Speed Control of a SCIM Chopper Speed Control of a WRIM Electronic

More information

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE KARTIK TAMVADA Department of E.E.E, V.S.Lakshmi Engineering College for Women, Kakinada, Andhra Pradesh,

More information

Performance Study of Multiphase Multilevel Inverter Rajshree Bansod*, Prof. S. C. Rangari**

Performance Study of Multiphase Multilevel Inverter Rajshree Bansod*, Prof. S. C. Rangari** International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 International Conference on Industrial Automation and Computing (ICIAC- 12-13 th April 214) RESEARCH ARTICLE OPEN

More information

Module 3. DC to DC Converters. Version 2 EE IIT, Kharagpur 1

Module 3. DC to DC Converters. Version 2 EE IIT, Kharagpur 1 Module 3 DC to DC Converters Version 2 EE IIT, Kharagpur 1 Lesson 2 Commutation of Thyristor-Based Circuits Part-II Version 2 EE IIT, Kharagpur 2 This lesson provides the reader the following: (i) (ii)

More information

3.1.Introduction. Synchronous Machines

3.1.Introduction. Synchronous Machines 3.1.Introduction Synchronous Machines A synchronous machine is an ac rotating machine whose speed under steady state condition is proportional to the frequency of the current in its armature. The magnetic

More information

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive Venkata Anil Babu Polisetty 1, B.R.Narendra 2 PG Student [PE], Dept. of EEE, DVR. & Dr.H.S.MIC College of Technology, AP, India 1 Associate

More information

SINGLE PHASE CURRENT SOURCE INVERTER (C.S.I)

SINGLE PHASE CURRENT SOURCE INVERTER (C.S.I) Power Electronics Laboratory SINGLE PHASE CURRENT SOURCE INVERTER (C.S.I) OBJECT: To study the gate firing pulses. To observe and measure the voltages across the Thyristors and across the Load for a current

More information

Resonant Controller to Minimize THD for PWM Inverter

Resonant Controller to Minimize THD for PWM Inverter IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 10, Issue 3 Ver. III (May Jun. 2015), PP 49-53 www.iosrjournals.org Resonant Controller to

More information

CHAPTER 3 VOLTAGE SOURCE INVERTER (VSI)

CHAPTER 3 VOLTAGE SOURCE INVERTER (VSI) 37 CHAPTER 3 VOLTAGE SOURCE INVERTER (VSI) 3.1 INTRODUCTION This chapter presents speed and torque characteristics of induction motor fed by a new controller. The proposed controller is based on fuzzy

More information

Simulation & Implementation Of Three Phase Induction Motor On Single Phase By Using PWM Techniques

Simulation & Implementation Of Three Phase Induction Motor On Single Phase By Using PWM Techniques Simulation & Implementation Of Three Phase Induction Motor On Single Phase By Using PWM Techniques Ashwini Kadam 1,A.N.Shaikh 2 1 Student, Department of Electronics Engineering, BAMUniversity,akadam572@gmail.com,9960158714

More information

NPTEL

NPTEL NPTEL Syllabus Pulse width Modulation for Power Electronic Converters - Video course COURSE OUTLINE Converter topologies for AC/DC and DC/AC power conversion, overview of applications of voltage source

More information

CHAPTER 5 MODIFIED SINUSOIDAL PULSE WIDTH MODULATION (SPWM) TECHNIQUE BASED CONTROLLER

CHAPTER 5 MODIFIED SINUSOIDAL PULSE WIDTH MODULATION (SPWM) TECHNIQUE BASED CONTROLLER 74 CHAPTER 5 MODIFIED SINUSOIDAL PULSE WIDTH MODULATION (SPWM) TECHNIQUE BASED CONTROLLER 5.1 INTRODUCTION Pulse Width Modulation method is a fixed dc input voltage is given to the inverters and a controlled

More information

CHAPTER 4 CONTROL ALGORITHM FOR PROPOSED H-BRIDGE MULTILEVEL INVERTER

CHAPTER 4 CONTROL ALGORITHM FOR PROPOSED H-BRIDGE MULTILEVEL INVERTER 65 CHAPTER 4 CONTROL ALGORITHM FOR PROPOSED H-BRIDGE MULTILEVEL INVERTER 4.1 INTRODUCTION Many control strategies are available for the control of IMs. The Direct Torque Control (DTC) is one of the most

More information

HIGH LOW Astable multivibrators HIGH LOW 1:1

HIGH LOW Astable multivibrators HIGH LOW 1:1 1. Multivibrators A multivibrator circuit oscillates between a HIGH state and a LOW state producing a continuous output. Astable multivibrators generally have an even 50% duty cycle, that is that 50% of

More information

Experiment 4: Three-Phase DC-AC Inverter

Experiment 4: Three-Phase DC-AC Inverter 1.0 Objectives he University of New South Wales School of Electrical Engineering & elecommunications ELEC4614 Experiment 4: hree-phase DC-AC Inverter his experiment introduces you to a three-phase bridge

More information

3 PHASE INVERTER WITH 180 AND 120 CONDUCTION MODE

3 PHASE INVERTER WITH 180 AND 120 CONDUCTION MODE 3 PHASE INVERTER WITH 180 AND 120 CONDUCTION MODE Mahendra G. Mathukiya 1 1 Electrical Department, C.U. Shah College of Engineering & Technology Abstract Today most of the appliances and machine works

More information

Design of Three Phase SVPWM Inverter Using dspic

Design of Three Phase SVPWM Inverter Using dspic Design of Three Phase SVPWM Inverter Using dspic Pritam Vikas Gaikwad 1, Prof. M. F. A. R. Satarkar 2 1,2 Electrical Department, Dr. Babasaheb Ambedkar Technological University (India) ABSTRACT Induction

More information

IMPORTANCE OF VSC IN HVDC

IMPORTANCE OF VSC IN HVDC IMPORTANCE OF VSC IN HVDC Snigdha Sharma (Electrical Department, SIT, Meerut) ABSTRACT The demand of electrical energy has been increasing day by day. To meet these high demands, reliable and stable transmission

More information

Three Phase Dual Output Inverters for Photo Voltaice System with Three Switch Legs

Three Phase Dual Output Inverters for Photo Voltaice System with Three Switch Legs Three Phase Dual Output Inverters for Photo Voltaice System with Three Switch Legs Sakthivel K 1, B. Vaidianathan 2 1 PG Scholar, Bharath University, Chennai, India 2 Assistant Professor 2, Bharath University,

More information

Tagore Engineering College Rathanamangalam, Melkottaiyur ( Post ), Vandular via Chennai 127

Tagore Engineering College Rathanamangalam, Melkottaiyur ( Post ), Vandular via Chennai 127 Tagore Engineering College Rathanamangalam, Melkottaiyur ( Post ), Vandular via Chennai 127 Department of Electrical and Electronics Engineering M.E - Power Electronics and Drives PX 7103 Analysis and

More information

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans. Electronic Measurements & Instrumentation

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans.   Electronic Measurements & Instrumentation UNIT 2 Q.1) Describe the functioning of standard signal generator Ans. STANDARD SIGNAL GENERATOR A standard signal generator produces known and controllable voltages. It is used as power source for the

More information

Use of Advanced Unipolar SPWM Technique for Higher Efficiency High Power Applications

Use of Advanced Unipolar SPWM Technique for Higher Efficiency High Power Applications 2 nd International Conference on Multidisciplinary Research & Practice P a g e 161 Use of Advanced Unipolar SPWM Technique for Higher Efficiency High Power Applications Naman Jadhav, Dhruv Shah Institute

More information

ELEC387 Power electronics

ELEC387 Power electronics ELEC387 Power electronics Jonathan Goldwasser 1 Power electronics systems pp.3 15 Main task: process and control flow of electric energy by supplying voltage and current in a form that is optimally suited

More information

International Journal of Advance Engineering and Research Development

International Journal of Advance Engineering and Research Development Scientific Journal of Impact Factor (SJIF): 4.72 International Journal of Advance Engineering and Research Development Volume 4, Issue 8, August -2017 e-issn (O): 2348-4470 p-issn (P): 2348-6406 Analysis

More information

SCOTT TRANSFORMER AND DIODE CLAMPED INVERTER FED INDUCTION MOTOR BASED ON FOC

SCOTT TRANSFORMER AND DIODE CLAMPED INVERTER FED INDUCTION MOTOR BASED ON FOC RESEARCH ARTICLE OPEN ACCESS SCOTT TRANSFORMER AND DIODE CLAMPED INVERTER FED INDUCTION MOTOR BASED ON FOC 1, Ms. Snehal M. Khobragade, 2, Prof.B.S.Dani Mtech(IDC) pursuing Priyadarshini college of Engineering

More information

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER 97 CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER 6.1 INTRODUCTION Multi level inverters are proven to be an ideal technique for improving the voltage and current profile to closely match with the sinusoidal

More information

POWER ELECTRONICS LAB MANUAL

POWER ELECTRONICS LAB MANUAL JIS College of Engineering (An Autonomous Institution) Department of Electrical Engineering POWER ELECTRONICS LAB MANUAL Exp-1. Study of characteristics of an SCR AIM: To obtain the V-I characteristics

More information

A Novel Five-level Inverter topology Applied to Four Pole Induction Motor Drive with Single DC Link

A Novel Five-level Inverter topology Applied to Four Pole Induction Motor Drive with Single DC Link Research Article International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347-5161 2014 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet A Novel

More information

Pulsewidth Modulation for Power Electronic Converters Prof. G. Narayanan Department of Electrical Engineering Indian Institute of Science, Bangalore

Pulsewidth Modulation for Power Electronic Converters Prof. G. Narayanan Department of Electrical Engineering Indian Institute of Science, Bangalore Pulsewidth Modulation for Power Electronic Converters Prof. G. Narayanan Department of Electrical Engineering Indian Institute of Science, Bangalore Lecture - 36 Analysis of overmodulation in sine-triangle

More information

Dr.Arkan A.Hussein Power Electronics Fourth Class. Operation and Analysis of the Three Phase Fully Controlled Bridge Converter

Dr.Arkan A.Hussein Power Electronics Fourth Class. Operation and Analysis of the Three Phase Fully Controlled Bridge Converter Operation and Analysis of the Three Phase Fully Controlled Bridge Converter ١ Instructional Objectives On completion the student will be able to Draw the circuit diagram and waveforms associated with a

More information

Lecture 20. Single-phase SPWM inverters

Lecture 20. Single-phase SPWM inverters Lecture 20. Single-phase SPWM inverters 20.1 Sinusoidal Pulse Width Modulation (SPWM) In this scheme a sinusoidal modulating voltage ec of the desired output frequency f o is compared with a higher frequency

More information

Simulation And Comparison Of Space Vector Pulse Width Modulation For Three Phase Voltage Source Inverter

Simulation And Comparison Of Space Vector Pulse Width Modulation For Three Phase Voltage Source Inverter Simulation And Comparison Of Space Vector Pulse Width Modulation For Three Phase Voltage Source Inverter Associate Prof. S. Vasudevamurthy Department of Electrical and Electronics Dr. Ambedkar Institute

More information

Minimization Of Total Harmonic Distortion Using Pulse Width Modulation Technique

Minimization Of Total Harmonic Distortion Using Pulse Width Modulation Technique IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 10, Issue 3 Ver. IV (May Jun. 2015), PP 01-12 www.iosrjournals.org Minimization Of Total Harmonic

More information

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL 14 CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL 2.1 INTRODUCTION Power electronics devices have many advantages over the traditional power devices in many aspects such as converting

More information

Induction Motor Drive using SPWM Fed Five Level NPC Inverter for Electric Vehicle Application

Induction Motor Drive using SPWM Fed Five Level NPC Inverter for Electric Vehicle Application IJIRST International Journal for Innovative Research in Science & Technology Volume 4 Issue 7 November 2017 ISSN (online): 2349-6010 Induction Motor Drive using SPWM Fed Five Level NPC Inverter for Electric

More information

POWER- SWITCHING CONVERTERS Medium and High Power

POWER- SWITCHING CONVERTERS Medium and High Power POWER- SWITCHING CONVERTERS Medium and High Power By Dorin O. Neacsu Taylor &. Francis Taylor & Francis Group Boca Raton London New York CRC is an imprint of the Taylor & Francis Group, an informa business

More information

CHAPTER 3 H BRIDGE BASED DVR SYSTEM

CHAPTER 3 H BRIDGE BASED DVR SYSTEM 23 CHAPTER 3 H BRIDGE BASED DVR SYSTEM 3.1 GENERAL The power inverter is an electronic circuit for converting DC power into AC power. It has been playing an important role in our daily life, as well as

More information

Modeling and Simulation of Matrix Converter Using Space Vector PWM Technique

Modeling and Simulation of Matrix Converter Using Space Vector PWM Technique Modeling and Simulation of Matrix Converter Using Space Vector PWM Technique O. Hemakesavulu 1, T. Brahmananda Reddy 2 1 Research Scholar [PP EEE 0011], EEE Department, Rayalaseema University, Kurnool,

More information

Module 1. Introduction. Version 2 EE IIT, Kharagpur

Module 1. Introduction. Version 2 EE IIT, Kharagpur Module 1 Introduction Lesson 1 Introducing the Course on Basic Electrical Contents 1 Introducing the course (Lesson-1) 4 Introduction... 4 Module-1 Introduction... 4 Module-2 D.C. circuits.. 4 Module-3

More information

UNIVERSITY QUESTIONS. Unit-1 Introduction to Power Electronics

UNIVERSITY QUESTIONS. Unit-1 Introduction to Power Electronics UNIVERSITY QUESTIONS Unit-1 Introduction to Power Electronics 1. Give the symbol and characteristic features of the following devices. (i) SCR (ii) GTO (iii) TRIAC (iv) IGBT (v) SIT (June 2012) 2. What

More information

Speed Control of Induction Motor using Space Vector Modulation

Speed Control of Induction Motor using Space Vector Modulation SSRG International Journal of Electrical and Electronics Engineering (SSRG-IJEEE) volume Issue 12 December 216 Speed Control of Induction Motor using Space Vector Modulation K Srinivas Assistant Professor,

More information

CHAPTER 3 MODIFIED SINE PWM VSI FED INDUCTION MOTOR DRIVE

CHAPTER 3 MODIFIED SINE PWM VSI FED INDUCTION MOTOR DRIVE CHAPTER 3 MOIFIE INE PWM VI FE INUCTION MOTOR RIVE 3. 1 INTROUCTION Three phase induction motors are the most widely used motors for industrial control and automation. Hence they are often called the workhorse

More information

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 05 Issue: 12 Dec p-issn:

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 05 Issue: 12 Dec p-issn: Analysis of Sine Pulse width Modulation (SPWM) and Third Harmonic Pulse Width Modulation(THPWM) with Various Amplitude and Frequency Modulation of Three Phase Voltage Source Inverter Mohd Mustafa Mohiuddin

More information

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK INDUCTION MOTOR DRIVE WITH SINGLE DC LINK TO MINIMIZE ZERO SEQUENCE CURRENT IN

More information

CHAPTER - 3 CONVENTIONAL SOURCE INVERTER FED INDUCTION MOTOR DRIVE. output voltage could be fixed or variable at a fixed or variable frequency.

CHAPTER - 3 CONVENTIONAL SOURCE INVERTER FED INDUCTION MOTOR DRIVE. output voltage could be fixed or variable at a fixed or variable frequency. CHAPTER - 3 CONVENTIONAL SOURCE INVERTER FED INDUCTION MOTOR DRIVE 3.1. Introduction The objective of this chapter is to describe conventional source inverters, modes of operations and comparisons. DC

More information

Simulation of Five Phase Voltage Source Inverter with Different Excitation for Star Connected Load

Simulation of Five Phase Voltage Source Inverter with Different Excitation for Star Connected Load Simulation of Five Phase Voltage Source Inverter with Different Excitation for Star Connected Load M.A Inayathullaah #1, Dr. R. Anita *2 # Department of Electrical and Electronics Engineering, Periyar

More information

Examples Paper 3B3/4 DC-AC Inverters, Resonant Converter Circuits. dc to ac converters

Examples Paper 3B3/4 DC-AC Inverters, Resonant Converter Circuits. dc to ac converters Straightforward questions are marked! Tripos standard questions are marked * Examples Paper 3B3/4 DC-AC Inverters, Resonant Converter Circuits dc to ac converters! 1. A three-phase bridge converter using

More information

Simulation of Speed Control of Induction Motor with DTC Scheme Patel Divyaben Lalitbhai 1 Prof. C. A. Patel 2 Mr. B. R. Nanecha 3

Simulation of Speed Control of Induction Motor with DTC Scheme Patel Divyaben Lalitbhai 1 Prof. C. A. Patel 2 Mr. B. R. Nanecha 3 IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 09, 2015 ISSN (online): 2321-0613 Simulation of Speed Control of Induction Motor with DTC Scheme Patel Divyaben Lalitbhai

More information

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM 64 CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM 4.1 INTRODUCTION Power electronic devices contribute an important part of harmonics in all kind of applications, such as power rectifiers, thyristor converters

More information

ISSN: [Shukla* et al., 6(10): October, 2017] Impact Factor: 4.116

ISSN: [Shukla* et al., 6(10): October, 2017] Impact Factor: 4.116 IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY SVPWM & SPWM CONTROLLER BASED PERFORMANCE EVALUATION OF THREE PHASE INDUCTION MOTOR Niraj Kumar Shukla *1, Rajeev Srivastava 2

More information

DHANALAKSHMI SRINIVASAN COLLEGE OF ENGINEERING AND TECHNOLY Mamallapuram chennai

DHANALAKSHMI SRINIVASAN COLLEGE OF ENGINEERING AND TECHNOLY Mamallapuram chennai DHANALAKSHMI SRINIVASAN COLLEGE OF ENGINEERING AND TECHNOLY Mamallapuram chennai DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK V SEMESTER EE6503 - POWER ELECTRONICS Regulation 2013

More information

EE POWER ELECTRONICS

EE POWER ELECTRONICS EE6503 - POWER ELECTRONICS UNIT III - DC TO DC CONVERTER PART A 1.What is meant by time ratio or PWM control (duty cycle) of a DC chopper? (M/J16) The ratio of a period to the total time period is known

More information

Three Phase Induction Motor Drive Using Single Phase Inverter and Constant V/F method

Three Phase Induction Motor Drive Using Single Phase Inverter and Constant V/F method Three Phase Induction Motor Drive Using Single Phase Inverter and Constant V/F method Nitin Goel 1, Shashi yadav 2, Shilpa 3 Assistant Professor, Dept. of EE, YMCA University of Science & Technology, Faridabad,

More information

2.0 AC CIRCUITS 2.1 AC VOLTAGE AND CURRENT CALCULATIONS. ECE 4501 Power Systems Laboratory Manual Rev OBJECTIVE

2.0 AC CIRCUITS 2.1 AC VOLTAGE AND CURRENT CALCULATIONS. ECE 4501 Power Systems Laboratory Manual Rev OBJECTIVE 2.0 AC CIRCUITS 2.1 AC VOLTAGE AND CURRENT CALCULATIONS 2.1.1 OBJECTIVE To study sinusoidal voltages and currents in order to understand frequency, period, effective value, instantaneous power and average

More information

PERFORMANCE EVALUATION OF THREE PHASE SCALAR CONTROLLED PWM RECTIFIER USING DIFFERENT CARRIER AND MODULATING SIGNAL

PERFORMANCE EVALUATION OF THREE PHASE SCALAR CONTROLLED PWM RECTIFIER USING DIFFERENT CARRIER AND MODULATING SIGNAL Journal of Engineering Science and Technology Vol. 10, No. 4 (2015) 420-433 School of Engineering, Taylor s University PERFORMANCE EVALUATION OF THREE PHASE SCALAR CONTROLLED PWM RECTIFIER USING DIFFERENT

More information

Conventional Paper-II-2011 Part-1A

Conventional Paper-II-2011 Part-1A Conventional Paper-II-2011 Part-1A 1(a) (b) (c) (d) (e) (f) (g) (h) The purpose of providing dummy coils in the armature of a DC machine is to: (A) Increase voltage induced (B) Decrease the armature resistance

More information

CHAPTER 2 D-Q AXES FLUX MEASUREMENT IN SYNCHRONOUS MACHINES

CHAPTER 2 D-Q AXES FLUX MEASUREMENT IN SYNCHRONOUS MACHINES 22 CHAPTER 2 D-Q AXES FLUX MEASUREMENT IN SYNCHRONOUS MACHINES 2.1 INTRODUCTION For the accurate analysis of synchronous machines using the two axis frame models, the d-axis and q-axis magnetic characteristics

More information

UG Student, Department of Electrical Engineering, Gurunanak Institute of Engineering & Technology, Nagpur

UG Student, Department of Electrical Engineering, Gurunanak Institute of Engineering & Technology, Nagpur A Review: Modelling of Permanent Magnet Brushless DC Motor Drive Ravikiran H. Rushiya 1, Renish M. George 2, Prateek R. Dongre 3, Swapnil B. Borkar 4, Shankar S. Soneker 5 And S. W. Khubalkar 6 1,2,3,4,5

More information

Comparative Study of Pulse Width Modulated and Phase Controlled Rectifiers

Comparative Study of Pulse Width Modulated and Phase Controlled Rectifiers Comparative Study of Pulse Width Modulated and Phase Controlled Rectifiers Dhruv Shah Naman Jadhav Keyur Mehta Setu Pankhaniya Abstract Fixed DC voltage is one of the very basic requirements of the electronics

More information

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System 1 G.Balasundaram, 2 Dr.S.Arumugam, 3 C.Dinakaran 1 Research Scholar - Department of EEE, St.

More information

Speed Control of DC Motor Using Phase-Locked Loop

Speed Control of DC Motor Using Phase-Locked Loop Speed Control of DC Motor Using Phase-Locked Loop Authors Shaunak Vyas Darshit Shah Affiliations B.Tech. Electrical, Nirma University, Ahmedabad E-mail shaunak_vyas1@yahoo.co.in darshit_shah1@yahoo.co.in

More information

Literature Review for Shunt Active Power Filters

Literature Review for Shunt Active Power Filters Chapter 2 Literature Review for Shunt Active Power Filters In this chapter, the in depth and extensive literature review of all the aspects related to current error space phasor based hysteresis controller

More information

ELG4139: DC to AC Converters

ELG4139: DC to AC Converters ELG4139: DC to AC Converters Converts DC to AC power by switching the DC input voltage (or current) in a pre-determined sequence so as to generate AC voltage (or current) output. I DC I ac + + V DC V ac

More information

Ch.8 INVERTER. 8.1 Introduction. 8.2 The Full-Bridge Converter. 8.3 The Square-Wave Inverter. 8.4 Fourier Series Analysis

Ch.8 INVERTER. 8.1 Introduction. 8.2 The Full-Bridge Converter. 8.3 The Square-Wave Inverter. 8.4 Fourier Series Analysis Ch.8 INVERTER 8.1 Introduction 8.2 The Full-Bridge Converter 8.3 The Square-Wave Inverter 8.4 Fourier Series Analysis 8.5 Total Harmonic Distortion 8.6 PSpice Simulation of Square-Wave Inverters 8.7 Amplitude

More information

DESIGN AND IMPLEMENTATION OF SINGLE PHASE INVERTER

DESIGN AND IMPLEMENTATION OF SINGLE PHASE INVERTER DESIGN AND IMPLEMENTATION OF SINGLE PHASE INVERTER PROF. A. N. WADEKAR, abhijitwadekar69@gmai.com J B BANDGAR, bandgarjayshri3@gmail.com S V JADHAV swapnalij1996@gmail.com U.S MANE, ulkamane@gmail.com

More information

MICROPROCESSOR BASED PWM INVERTER SYSTEM AND ITS USE FOR CONTROL OF INDUCTION MOTOR

MICROPROCESSOR BASED PWM INVERTER SYSTEM AND ITS USE FOR CONTROL OF INDUCTION MOTOR MICROPROCESSOR BASED PWM INVERTER SYSTEM AND ITS USE FOR CONTROL OF INDUCTION MOTOR By MEHRAN MOTAMED EKTESSABI Thesis submitted in fulfilment of the requirements for the award of the degree of DOCTOR

More information

AC VOLTAGE CONTROLLER (RMS VOLTAGE CONTROLLERS)

AC VOLTAGE CONTROLLER (RMS VOLTAGE CONTROLLERS) AC VOLTAGE CONTROLLER (RMS VOLTAGE CONTROLLERS) INTRODUCTION AC voltage controllers (AC line voltage controllers): are employed to vary the RMS value of the alternating voltage applied to a load circuit

More information

VALLIAMMAI ENGINEERING COLLEGE DEPARTMENT OF ELECTRONICS AND INSTRUMENTATION

VALLIAMMAI ENGINEERING COLLEGE DEPARTMENT OF ELECTRONICS AND INSTRUMENTATION VALLIAMMAI ENGINEERING COLLEGE DEPARTMENT OF ELECTRONICS AND INSTRUMENTATION Sem / Branch : V /EIE Subject code /Title: EI2301/Industrial Electronics UNIT-1 POWER DEVICES 1. What are the different methods

More information

Development of a Single-Phase PWM AC Controller

Development of a Single-Phase PWM AC Controller Pertanika J. Sci. & Technol. 16 (2): 119-127 (2008) ISSN: 0128-7680 Universiti Putra Malaysia Press Development of a Single-Phase PWM AC Controller S.M. Bashi*, N.F. Mailah and W.B. Cheng Department of

More information

Power Factor Correction for Chopper Fed BLDC Motor

Power Factor Correction for Chopper Fed BLDC Motor ISSN No: 2454-9614 Power Factor Correction for Chopper Fed BLDC Motor S.Dhamodharan, D.Dharini, S.Esakki Raja, S.Steffy Minerva *Corresponding Author: S.Dhamodharan E-mail: esakkirajas@yahoo.com Department

More information

Performance Improvement of BLDC Motor Based on Quasi-Z Source Network

Performance Improvement of BLDC Motor Based on Quasi-Z Source Network Performance Improvement of BLDC Motor Based on Quasi-Z Source Network N.Tharun Ram 1 G.Balaji 2 1PG Scholar, Department of EEE, Gudlavalleru Engineering College, Gudlavalleru, Krishna Dt, Andhra Pradesh,

More information