LINEAMPS LineAmps for all lines

Size: px
Start display at page:

Download "LINEAMPS LineAmps for all lines"

Transcription

1 LINEAMPS New System of Dynamic Line Ratings Electrotech Enterprises LLC, USA

2 LINEAMPS New System of Dynamic Line Ratings Provides dynamic ratings of all lines in an electrical network Includes overhead and underground lines Forecasts hourly values of line Ampacity for a week in advance Runs autonomously Integration with Google maps for easy visualization of lines, line current, and site location information View of selected Burbank transmission line in Google map

3 LINEAMPS FOR UNDERGROUND CABLES Underground Cable Dynamic Rating LineAmps calculates Ampacity of all transmissions lines including transmission lines having both overhead lines and underground cables Underground Cable Dynamic Ratings includes duct bank model and mutual heating from adjacent cable circuits in the same duct

4 LINEAMPS FOR OVERHEAD CONDUCTORS Overhead Conductor Dynamic Rating Includes database of different types of conductors New conductors can be easily added to the database by user

5 VIEW LINES IN GOOGLE MAP Dynamic rating of all lines View geographic location of all lines in the electrical network View line Ampacity and conductor temperature by clicking on a line View location of transmission line sites and site data View weather stations and weather data by clicking on weather stations

6 AUTOMATIC AMPACITY CALCULATIONS Automatic Ampacity calculation of all lines are updated at each hour Real Time Updates: Normal Ampacity for steady state condition Dynamic Ampacity for short duration overload (30 min overload: Burbank example) Dynamic Ampacity for long duration overload (2 hr overload: Burbank example) Display Ampacity limiting site for each line (critical section) Now includes location of critical Site

7 STEADY STATE CALCULATIONS Underground Cable Temperature

8 STEADY STATE CALCULATIONS Underground Cable Ampacity

9 STEADY STATE CALCULATIONS Overhead Conductor Temperature

10 STEADY STATE CALCULATIONS Overhead Conductor Ampacity

11 DYNAMIC STATE CALCULATIONS Underground Cable Ampacity

12 DYNAMIC STATE CALCULATIONS Underground Cable Time to Reach Max Temperature

13 DYNAMIC STATE CALCULATIONS Overhead Conductor Ampacity

14 TRANSIENT STATE CALCULATIONS Overhead Conductor Temperature Heating

15 TRANSIENT STATE CALCULATIONS Overhead Conductor Temperature Cooling

16 REAL TIME TRANSMISSION LINE OPERATION Time to Reach Critical Temperature These are real time calculations updated every 10 seconds

17 FORECAST AMPACITY LineAmps provides hourly values of line ampacity up to a week in advance, used for generation and transmission system planning. Just select a line from the list of lines and instantly view line ratings for a week in advance.

18 FORECAST AMPACITY Hourly values of line ampacity up to a week in advance are output to LineAmps database for access by external programs.

19 BATCH CALCULATION TO EXCEL Perform series of steady state and dynamic calculations

20 BATCH CALCULATION TO EXCEL Perform series of steady and dynamic state calculations

21 BATCH CALCULATION TO EXCEL Result of Steady State and Dynamic Runs

22 DATABASE MANAGER LineAmps Database includes the following user configurable databases: Overhead Conductors Underground Cables Transmission Lines Weather Stations T/L Voltages

23 TRANSMISSION LINE DATABASE LineAmps Transmission Line Database includes the following data: Line Name Site Data Weather Stations Line Element: Overhead Line Underground Cable Power Transformer Circuit Breaker Isolator Current Transformer Bus Bar

24 UNDERGROUND CABLE DATABASE LineAmps Underground Cable Database includes the following data Cable Type: XLPE, PE Conductor Duct Soil Jacket Insulation Operating Temperature

25 WEATHER STATION DATABASE LineAmps Weather Station Database includes the following data Station Name Location: Latitude, Longitude URL Web site: TV5 CNN NOAA Accuweather Weather Underground

26 EXAMPLE WEATHER DATA LineAmps inputs weather data automatically from the web: CNN NOAA TV5 Weather Underground

27 FURTHER READING

FACILITY RATINGS METHOD TABLE OF CONTENTS

FACILITY RATINGS METHOD TABLE OF CONTENTS FACILITY RATINGS METHOD TABLE OF CONTENTS 1.0 PURPOSE... 2 2.0 SCOPE... 3 3.0 COMPLIANCE... 4 4.0 DEFINITIONS... 5 5.0 RESPONSIBILITIES... 7 6.0 PROCEDURE... 8 6.4 Generating Equipment Ratings... 9 6.5

More information

Transmission Facilities Rating Methodology for Florida

Transmission Facilities Rating Methodology for Florida Document title Transmission Facilities Rating Methodology for Florida Document number EGR-TRMF-00001 Applies to: Transmission Engineering, Transmission System Operations, and Transmission Planning Duke

More information

10kV XLPE cable ampacity improvement research in Guangzhou area

10kV XLPE cable ampacity improvement research in Guangzhou area 10kV XLPE cable ampacity improvement research in Guangzhou area Zhixin SUO Guopei WU Jian CHEN China Southern Power Grid China China Southern Power Grid China China Southern Power Grid China soney@126.com

More information

ECET 211 Electric Machines & Controls Lecture 3-1 (Part 1 of 2) Motor Transformers and Distribution Systems

ECET 211 Electric Machines & Controls Lecture 3-1 (Part 1 of 2) Motor Transformers and Distribution Systems ECET 211 Electric Machines & Controls Lecture 3-1 (Part 1 of 2) Motor Transformers and Distribution Systems Text Book: Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill,

More information

Online Dynamic Assessment of Transmission Ratings for Transmission Constraint Management in Power System and Market Operations

Online Dynamic Assessment of Transmission Ratings for Transmission Constraint Management in Power System and Market Operations Online Dynamic Assessment of Transmission Ratings for Transmission Constraint Management in Power System and Market Operations Kwok W. Cheung, Ph.D., PE, PMP, FIEEE R&D Director, Network Management Solutions

More information

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS 1.0 SCOPE 2.0 BONDING METHODS 2.1 Introduction 2.2 Design 2.3 Single-Point Bonding 2.4 Cross Bonding 2.5 Sheath Sectionalizing Joints 2.6 Sheath Standing Voltage 2.7 Sheath Voltage at Through Fault 2.8

More information

Automated Fault Detection With PQ Monitors

Automated Fault Detection With PQ Monitors Automated Fault Detection With PQ Monitors Theo Laughner, PE Sr. Program Manager of Power Quality Acknowledgements: Anthony Murphy, PE October 12, 2015 Background Case Studies (5) Needs Tools Conclusion

More information

Transmission of Electrical Energy

Transmission of Electrical Energy Transmission of Electrical Energy Electrical energy is carries by conductors such as overhead transmission lines and underground cables. The conductors are usually aluminum cable steel reinforced (ACSR),

More information

Criteria. Table of Contents

Criteria. Table of Contents Criteria Department: Document No: Asset Management CR-0062 v05 Title: UNDERGROUND TRANSMISSION LINE AMPACITY RATINGS Issue Date: Previous Date: 05-24-2010 10-06-2009 Table of Contents 1.0 Scope...2 2.0

More information

A Novel Gui Simulation Program Designed for Teaching of Underground Power Cables

A Novel Gui Simulation Program Designed for Teaching of Underground Power Cables 2009 International Conference on Education Technology and Computer A Novel Gui Simulation Program Designed for Teaching of Underground Power Cables Yunus BİÇEN Department of Industrial Electronics, Duzce

More information

Power System Protection Where Are We Today?

Power System Protection Where Are We Today? 1 Power System Protection Where Are We Today? Meliha B. Selak Power System Protection & Control IEEE PES Distinguished Lecturer Program Preceding IEEE PES Vice President for Chapters melihas@ieee.org PES

More information

TRANSMISSION FACILITIES...7

TRANSMISSION FACILITIES...7 Table of Contents 1. INTRODUCTION...4 1.1. Objective... 4 1.2. NERC FAC-008 Compliance... 4 1.3. Seminole s Normal Rating... 5 1.4. Seminole s Four-Hour Rating... 5 1.5. Seminole s Emergency Rating...

More information

AMERICAN PUBLIC TRANSIT ASSOCIATION 2003 RAIL TRANSIT CONFERENCE. Cable Rating Considerations for Direct Current Traction Power Systems

AMERICAN PUBLIC TRANSIT ASSOCIATION 2003 RAIL TRANSIT CONFERENCE. Cable Rating Considerations for Direct Current Traction Power Systems AMERICAN PUBLIC TRANSIT ASSOCIATION 2003 RAIL TRANSIT CONFERENCE June 9, 2003 Rating Considerations for R. W. Benjamin Stell. P.E Manager of Power Systems The HNTB Companies 1 Burlington Woods Burlington,

More information

Electrical Power Systems

Electrical Power Systems Electrical Power Systems CONCEPT, THEORY AND PRACTICE SECOND EDITION SUBIR RAY Professor MVJ College of Engineering Bangalore PHI Learning Pfcte tofm Delhi-110092 2014 Preface xv Preface to the First Edition

More information

MV water-proof and water tree retardant power cable

MV water-proof and water tree retardant power cable MV water-proof and water tree retardant power cable 1 Standard GB/T16-8 1kV 35kV, IEC The products should be manufactured according to standard GB/T16-8 and also as per IEC, BS and HD as requested. 2 Application

More information

The fundamental interconnectedness of all things. Rob Westmancoat Senior Strategy Analyst

The fundamental interconnectedness of all things. Rob Westmancoat Senior Strategy Analyst The fundamental interconnectedness of all things Rob Westmancoat Senior Strategy Analyst Image courtesy of www.digitalspy.com "I'm very glad you asked me that, Mrs Rawlinson. The term `holistic' refers

More information

MidAmerican Energy Company 69 kv Facility Ratings Methodology

MidAmerican Energy Company 69 kv Facility Ratings Methodology MidAmerican Energy Company 69 kv Facility Ratings Methodology Version 1.0 Issued by: Luke Erichsen Reviewed by: Tom Mielnik Last Reviewed: 8/29/2012 1 1.0 Scope: This document provides MidAmerican Energy

More information

MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology

MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology For NERC Standard FAC-008-3 Version 3.4 1 Contents 1. Scope... 3 2. Establishment and Communication of Facility Ratings:... 3 2.1.

More information

120 / 240 VAC SINGLE SPLIT PHASE & MULTI-WIRE BRANCH CIRCUITS. Excerpt from G4 InverCharge Series Manual BY: VIJAY SHARMA ENGINEER

120 / 240 VAC SINGLE SPLIT PHASE & MULTI-WIRE BRANCH CIRCUITS. Excerpt from G4 InverCharge Series Manual BY: VIJAY SHARMA ENGINEER 120 / 240 VC SILE SPLIT PHSE & MULTI-WIRE RCH CIRCUITS Excerpt from 4 InverCharge Series Manual Y: VIJY SHRM EIEER 120 / 240 VC SILE SPLIT PHSE & MULTI-WIRE RCH CIRCUITS i IFO For purposes of explaining

More information

TABLE OF CONTENT

TABLE OF CONTENT Page : 1 of 34 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 3 REFERENCES

More information

Jason Harchick, P.E. Sr. Manager, System Planning and Protection Ryan Young Manager, Substation Engineering

Jason Harchick, P.E. Sr. Manager, System Planning and Protection Ryan Young Manager, Substation Engineering DLC s Brady IIB Project Jason Harchick, P.E. Sr. Manager, System Planning and Protection Ryan Young Manager, Substation Engineering Project Need In 2007, PJM and Duquesne Light Company (DLC) transmission

More information

Industrial Electrician Level 3

Industrial Electrician Level 3 Industrial Electrician Level 3 Industrial Electrician Unit: C1 Industrial Electrical Code I Level: Three Duration: 77 hours Theory: Practical: 77 hours 0 hours Overview: This unit is designed to provide

More information

Distance Protection of Cross-Bonded Transmission Cable-Systems

Distance Protection of Cross-Bonded Transmission Cable-Systems Downloaded from vbn.aau.dk on: April 19, 2019 Aalborg Universitet Distance Protection of Cross-Bonded Transmission Cable-Systems Bak, Claus Leth; F. Jensen, Christian Published in: Proceedings of the 12th

More information

DYNAMIC RATING SYSTEMS IN GENERAL AND IN A HIBRID 150 KV TRANSMISSION SYSTEM

DYNAMIC RATING SYSTEMS IN GENERAL AND IN A HIBRID 150 KV TRANSMISSION SYSTEM DYNAMIC RATING SYSTEMS IN GENERAL AND IN A HIBRID KV TRANSMISSION SYSTEM Frank DE WILD, KEMA Consulting (Netherlands), Frank.deWild@kema.com Wim BOONE, KEMA Consulting (Netherlands), Wim.Boone@kema.com

More information

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56 1. Two Electrical Technicians are discussing markings that are required for AC wiring. Tech A says that AC conductors must be rated for 600 volts and must have their jackets and individual conductors marked

More information

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES ( Data Sheets ) 11 kv XLPE-Insulated Three-Core Underground Cables (3x240 mm 2 ) ADWEA/ADDC/AADC STANDARD : D-AAA-CAB-11-3Cx240

More information

DESIGN OF A 45 CIRCUIT DUCT BANK

DESIGN OF A 45 CIRCUIT DUCT BANK DESIGN OF A 45 CIRCUIT DUCT BANK Mark COATES, ERA Technology Ltd, (UK), mark.coates@era.co.uk Liam G O SULLIVAN, EDF Energy Networks, (UK), liam.o sullivan@edfenergy.com ABSTRACT Bankside power station

More information

Circulating sheath currents in flat formation underground power lines

Circulating sheath currents in flat formation underground power lines Circulating sheath currents in flat formation underground power lines J.R. Riba Ruiz 1, Antoni Garcia 2, X. Alabern Morera 3 1 Department d'enginyeria Elèctrica, UPC EUETII-"L'Escola d'adoberia" Plaça

More information

Click to edit Master title style. Click to edit Master title style. Northern Powergrid Asset Recording Guidance

Click to edit Master title style. Click to edit Master title style. Northern Powergrid Asset Recording Guidance Click to edit Master title style Click to edit Master title style Northern Powergrid Asset Recording Guidance Rules for ICP & IDNO Version 1.0 April 2017 Introduction Accurate records for all assets are

More information

TECHNICAL TRAINING COURSES

TECHNICAL TRAINING COURSES TECHNICAL TRAINING COURSES MAY 14 18, 2018 DENVER, COLORADO Applied Electrical Distribution Theory Electrical Distribution Principles, Applications and Improvements COURSE HIGHLIGHTS Earn PDHs Earn 22

More information

Article 225: Outside Branch Circuits And Feeders

Article 225: Outside Branch Circuits And Feeders Part C: Code Book Questions Article 225: Outside Branch Circuits And Feeders 1.! Open (individual) aerial overhead conductors shall be insulated or covered when within! feet of a building.! (a) 10! (c)

More information

CUSTOM DESIGN COAXIAL CABLES BY SICAB

CUSTOM DESIGN COAXIAL CABLES BY SICAB CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency

More information

Tampa Electric Company Facility Rating Methodology Approved 11/20/2018

Tampa Electric Company Facility Rating Methodology Approved 11/20/2018 Tampa Electric Company Facility Rating Methodology Approved 11/20/2018 Effective Date: 12/01/2018 Responsible Department: System Planning Review Cycle: 3 Years Last Date Reviewed: 11/16/2018 Next Planned

More information

Bipole III Transmission Project

Bipole III Transmission Project Bipole III Transmission Project Clean Environment Commission Public Hearings Fall 2012 System Planning Ronald Mazur BP III Keewantinoow Limestone Kettle Kelsey Jenpeg Grand Rapids OVERVIEW Transmission

More information

Inventory Equipment/Operations

Inventory Equipment/Operations Inventory Equipment/Operations As indicated above, the first task should be to take an inventory of your wireless microphones. Fictional TV Station KWXYZ-HD operates on TV channel 45 in Albany, GA and

More information

Medium Voltage Power Cables

Medium Voltage Power Cables N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium

More information

A Methodology for Dynamically Adjusting a Transmission Line Rating on an Island Grid in the Caribbean

A Methodology for Dynamically Adjusting a Transmission Line Rating on an Island Grid in the Caribbean S. Bahadoorsingh et. al: A Methodology for Dynamically Adjusting a Transmission Line Rating on an Island Grid in the Caribbean 76 A Methodology for Dynamically Adjusting a Transmission Line Rating on an

More information

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength cross-linked polyethylene (XLPE) insulation, Type XHHW-2, cabled with bare copper grounding conductors

More information

RECOMMENDATION ITU-R P Characteristics of precipitation for propagation modelling

RECOMMENDATION ITU-R P Characteristics of precipitation for propagation modelling Rec. ITU-R P.837-4 1 RECOMMENDATION ITU-R P.837-4 Characteristics of precipitation for propagation modelling (Question ITU-R 21/3) (1992-1994-1999-21-23) The ITU Radiocommunication Assembly, considering

More information

Transmission Facilities Rating Methodology

Transmission Facilities Rating Methodology Document title Transmission Facilities Rating Methodology Document number EGR-TRMC-00009 Applies to: Transmission Engineering, Transmission System Operations, and Transmission Planning- Progress Energy

More information

LONGITUDINAL INDUCTION VOLTAGE MEASUREMENT ON COMMUNICATION CABLES RUNNING PARALLEL TO OVERHEAD LINES

LONGITUDINAL INDUCTION VOLTAGE MEASUREMENT ON COMMUNICATION CABLES RUNNING PARALLEL TO OVERHEAD LINES LONGITUDINAL INDUCTION VOLTAGE MEASUREMENT ON COMMUNICATION CABLES RUNNING PARALLEL TO OVERHEAD LINES IEEE PES Transmission and Distribution Conference_ Chicago April 2008 Dean Sharafi Introduction Electro-magnetic

More information

Number: Prepared by: TABLE OF CONTENTS

Number: Prepared by: TABLE OF CONTENTS Prepared by: C. J. McWhirter Issued by: D. J. Papadoulis Date: 30 August 2013 Page 1 of 19 TABLE OF CONTENTS Page 1 INTRODUCTION... 2 2 TRANSMISSION LINES... 2 3 TRANSFORMERS... 6 4 SHUNT REACTORS... 8

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated

More information

ELEC Transmission i and

ELEC Transmission i and ELEC-1104 Lecture 5: Transmission i and Distribution ib ti Power System Layout Transmission and Distribution The transmission system is to transmit a large amount of energy from the power stations s to

More information

E Series 9.00 (1/2) E series

E Series 9.00 (1/2) E series Clamp-on AC/DC current probes E Series The clamps use Hall effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. The elongated, narrow design of these clamps

More information

CONTENTS. 1. Introduction Generating Stations 9 40

CONTENTS. 1. Introduction Generating Stations 9 40 CONTENTS 1. Introduction 1 8 Importance of Electrical Energy Generation of Electrical Energy Sources of Energy Comparison of Energy Sources Units of Energy Relationship among Energy Units Efficiency Calorific

More information

Utility System Lightning Protection

Utility System Lightning Protection Utility System Lightning Protection Many power quality problems stem from lightning. Not only can the high-voltage impulses damage load equipment, but the temporary fault that follows a lightning strike

More information

3.1 Overview of ATCO Electric s URD System Design

3.1 Overview of ATCO Electric s URD System Design Page: 3-1 3.0 URD DESIGN GUIDELINES 3.1 Overview of ATCO Electric s URD System Design ATCO Electric s design for distribution power supply to URD areas is a primary looped supply system. This is generically

More information

ATCO ELECTRIC LTD. (Transmission System) SERVICE QUALITY AND RELIABILITY PERFORMANCE, MEASURES AND INDICES Revision 0

ATCO ELECTRIC LTD. (Transmission System) SERVICE QUALITY AND RELIABILITY PERFORMANCE, MEASURES AND INDICES Revision 0 ATCO ELECTRIC LTD. (Transmission System) SERVICE QUALITY AND RELIABILITY PERFORMANCE, MEASURES AND INDICES 2014-03-31 - Revision 0 EUB Decision 2007-071 Board Direction 52 For questions or comments regarding

More information

Research Article Survey of Induced Voltage and Current Phenomena in GIS Substation

Research Article Survey of Induced Voltage and Current Phenomena in GIS Substation Research Journal of pplied Sciences, Engineering and Technology 7(9): 179733, 14 DOI:1.196/rjaset.7.456 ISSN: 4-7459; e-issn: 4-7467 14 Maxwell Scientific Publication Corp. Submitted: February 7, 17 ccepted:

More information

Electrical Engineering. Power Systems. Comprehensive Theory with Solved Examples and Practice Questions. Publications

Electrical Engineering. Power Systems. Comprehensive Theory with Solved Examples and Practice Questions. Publications Electrical Engineering Power Systems Comprehensive Theory with Solved Examples and Practice Questions Publications Publications MADE EASY Publications Corporate Office: 44-A/4, Kalu Sarai (Near Hauz Khas

More information

Section 3. Test Procedures

Section 3. Test Procedures Section 3. Information contained within this section shall be read in conjunction with all sections of this manual Non - Compliant Test Results Where acceptable results are not attained in accordance with

More information

Need for grounding Codes and Standards for grounding Wind Turbine Generator grounding design Foundation + Horizontal Electrode grounding design

Need for grounding Codes and Standards for grounding Wind Turbine Generator grounding design Foundation + Horizontal Electrode grounding design IEEE PES Transmission and Distribution Conference 2008 Panel Session Large Wind Plant Collector Design Wind Farm Collector System Grounding by Steven W. Saylors, P.E. Chief Electrical Engineer Vestas Americas

More information

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables CATALOG OF PRODUCTS Isolated Copper Wire THHN/MTW/THWN-2 600V, single conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material.

More information

Utility Interconnection and System Protection

Utility Interconnection and System Protection Utility Interconnection and System Protection Alex Steselboim President, Advanced Power Technologies, Inc. Utility paralleling vs. isolated operation. Isochronous kw load sharing Reactive power (VAR) sharing

More information

[ENE02] Artificial neural network based arcing fault detection algorithm for underground distribution cable

[ENE02] Artificial neural network based arcing fault detection algorithm for underground distribution cable [ENE02] Artificial neural network based arcing fault detection algorithm for underground distribution cable Chan Wei Kian 1, Abdullah Asuhaimi Mohd. Zin 1, Md. Shah Majid 1, Hussein Ahmad 1, Zaniah Muda

More information

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions: KBR 18 Split-core current transformer Dimensions: Round conductor: 18 mm Transformer width: 41.6 mm Transformer height: 64.5 mm Transformer depth incl. fixing clasps: 67.3 mm General technical specifications:

More information

Chapter 6. WIRING SYSTEMS Safe Electrical Design

Chapter 6. WIRING SYSTEMS Safe Electrical Design Chapter 6 WIRING SYSTEMS Safe Electrical Design Topic 6-3 CABLE SELECTION BASED ON CURRENT CARRYING CAPACITY REQUIREMENTS INSTALLATION CONDITIONS Current carrying capacity (CCC) is the maximum continuous

More information

Measurements for validation of high voltage underground cable modelling

Measurements for validation of high voltage underground cable modelling Measurements for validation of high voltage underground cable modelling Unnur Stella Gudmundsdottir, Claus Leth Bak, Wojciech T. Wiechowski, Kim Søgaard, Martin Randrup Knardrupgård Abstract-- This paper

More information

Intermittent transient earth fault protection

Intermittent transient earth fault protection Intermittent transient earth fault protection The directional intermittent transient earth fault protection is used to detect short intermittent transient faults in compensated cable networks (figure 3).

More information

cable and pipe locators RD Utility cable and pipe locator

cable and pipe locators RD Utility cable and pipe locator cable and pipe locators RD7000 + Utility cable and pipe locator RD7000 + delivering fast, accurate, reliable and repeatable locate information for all utilities. Visually follow the target cable or pipe

More information

Amp Clamp W/True RMS

Amp Clamp W/True RMS 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 61746 600 Amp Clamp W/True RMS Ideal Catalog Number 61746 Manufacturer Ideal Ideal, Clamp Meter, Clamp-Pro, 600 Amp With

More information

User manual Vision Cable 1.4.2

User manual Vision Cable 1.4.2 User manual Vision Cable 1.4.2 8-9-2009 Phase to Phase BV Utrechtseweg 310 Postbus 100 6800 AC Arnhem The Netherlands T: +31 26 352 37 00 F: +31 26 352 37 09 www.phasetophase.com 1 Contents 1 Introduction...

More information

EI HIGH VOLTAGE INSULATION TESTING POLICY

EI HIGH VOLTAGE INSULATION TESTING POLICY Network(s): Summary: ENGINEERING INSTRUCTION EI 09-0001 HIGH VOLTAGE INSULATION TESTING POLICY EPN, LPN, SPN This engineering instruction details the policy for the on-site insulation testing of new and

More information

Power System Studies

Power System Studies Power System Studies Laois Ballyragget Cable Feasibility Study PE667-F4-R3-1-3 ESBI Engineering Solutions Stephen Court, 18/21 St Stephen s Green, Dublin 2, Ireland Telephone+353-1-73 8 Fax+353-1-661 66

More information

TNC Male Connector Crimp/Solder Attachment for RG214, RG9, RG225, RG393

TNC Male Connector Crimp/Solder Attachment for RG214, RG9, RG225, RG393 TNC Male Connector Crimp/Solder Attachment for RG214, RG9, RG225, RG393 RF Connectors Technical Data Sheet PE4447 Configuration TNC Male Connector MIL-STD-348A 50 Ohms Features Max Operating Frequency

More information

INTRODUCTION CURRENT CARRYING CAPACITY OF ELECTRIC CABLE

INTRODUCTION CURRENT CARRYING CAPACITY OF ELECTRIC CABLE ITRODUCTIO Good engineering design has always incorporated factors of safety. For mechanical design, the maximum design load would typically range from 25% of the ultimate tensile strength (U.T.S.) of

More information

FERRORESONANCE - its Occurrence and Control in Electricity Distribution Networks

FERRORESONANCE - its Occurrence and Control in Electricity Distribution Networks FERRORESONANCE - its Occurrence and Control in Electricity Distribution Networks by Alex Baitch FIEAust, CPEng Manager Network Capability, Integral Energy This paper was presented to the Annual Conference

More information

Index. b back-flashover 245 biomass 207 breakers 74 buchholz protection 235 busbar sectionalizer 193 business enterprises 18

Index. b back-flashover 245 biomass 207 breakers 74 buchholz protection 235 busbar sectionalizer 193 business enterprises 18 331 Index a activity plan 318 agricultural enterprise 21 annual increase factor 12 annuity factor 44, 156 annuity method 38 ANSI code numbers 237 arrester, protection level 245 assessment of losses 38

More information

ECP HV INSULATION TESTING

ECP HV INSULATION TESTING Document Number: ECP 11-0006 Network(s): Summary: All ENGINEERING COMMISSIONING PROCEDURE ECP 11-0006 HV INSULATION TESTING This standard details the policy for the on-site insulation testing of new and

More information

ESB National Grid Transmission Planning Criteria

ESB National Grid Transmission Planning Criteria ESB National Grid Transmission Planning Criteria 1 General Principles 1.1 Objective The specific function of transmission planning is to ensure the co-ordinated development of a reliable, efficient, and

More information

SURGE PROPAGATION AND PROTECTION OF UNDERGROUND DISTRIBUTION CABLES

SURGE PROPAGATION AND PROTECTION OF UNDERGROUND DISTRIBUTION CABLES SURGE PROPAGATION AND PROTECTION OF UNDERGROUND DISTRIBUTION CABLES Jae-bong LEE, Korea Electric Power Research Institute(KEPRI), (Korea), jbonglee@kepco.co.kr Ju-yong KIM, Korea Electric Power Research

More information

Power Quality Basics. Presented by. Scott Peele PE

Power Quality Basics. Presented by. Scott Peele PE Power Quality Basics Presented by Scott Peele PE PQ Basics Terms and Definitions Surge, Sag, Swell, Momentary, etc. Measurements Causes of Events Possible Mitigation PQ Tool Questions Power Quality Measurement

More information

Facility Ratings Methodology

Facility Ratings Methodology Facility Ratings Methodology FAC-008-3 Compliance Document Establishment Date: December 19, 2016 Effective Date: July 14 th, 2017 Approved by: Job Title Manager, Network & IRP Transmission Planning Name

More information

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION December 2016 SPECIFICATION 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION

More information

STATE OF NEW JERSEY BOARD OF PUBLIC UTILITIES

STATE OF NEW JERSEY BOARD OF PUBLIC UTILITIES STATE OF NEW JERSEY BOARD OF PUBLIC UTILITIES : IN THE MATTER OF THE PETITION OF : PUBLIC SERVICE ELECTRIC AND GAS : COMPANY FOR A DETERMINATION : PURSUANT TO THE PROVISIONS OF : N.J.S.A. 0:D-1 : BPU DOCKET

More information

Substation: From the Outside Looking In.

Substation: From the Outside Looking In. 1 Substation: From the Outside Looking In. Moderator n Ron Spataro AVO Training Institute Marketing Manager 2 Q&A n Send us your questions and comments during the presentation 3 Today s Presenter n Greg

More information

FAQ ON EARTHING STANDARDS 16/08/2018

FAQ ON EARTHING STANDARDS 16/08/2018 FAQ ON EARTHING STANDARDS 16/08/2018 This document has been updated to include changes made to substation earthing layouts that have been made necessary due to copper theft. The main changes to be aware

More information

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900 Coil Products Coil Products Customer partnership around the globe More than 250,000 coil products delivered to more than 170 countries. More than 60 years of operational experience. 35,000 in Europe 13,000

More information

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS Ljubomir KOJOVIC Cooper Power Systems - U.S.A. Lkojovic@cooperpower.com INTRODUCTION In steel facilities that use Electric Arc Furnaces (EAFs) to manufacture

More information

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 4 NOVEMBER 2009

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 4 NOVEMBER 2009 NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 4 NOVEMBER 2009 (12041004) 23 November (X-Paper) 09:00 12:00 Calculators may be used. This question paper consists of 7 pages.

More information

Synchrophasor Applications for Distribution Networks Enhancing T&D Operation and Information Exchange

Synchrophasor Applications for Distribution Networks Enhancing T&D Operation and Information Exchange Synchrophasor Applications for Distribution Networks Enhancing T&D Operation and Information Exchange Luigi Vanfretti, Hossein Hooshyar, Farhan Mahmood, Ravi Shankar Singh, Ali Bidadfar, Narender Singh,

More information

Zambezi (previously Caprivi) Link HVDC Interconnector: Review of Operational Performance in the First Five Years

Zambezi (previously Caprivi) Link HVDC Interconnector: Review of Operational Performance in the First Five Years 21, rue d Artois, F-758 PARIS B4-18 CIGRE 216 http : //www.cigre.org Zambezi (previously Caprivi) Link HVDC Interconnector: Review of Operational Performance in the First Five Years T G MAGG, Power System

More information

Tests on Extruded Cables

Tests on Extruded Cables Tests on Extruded Cables Pierre Argaut Chairman of CIGRE SC B1 October 26 th, 2011 At least, once in your life, you have heard these words: Development Tests Long-term Tests Prequalification Tests Extension

More information

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. : Order-No. : 7531 60 03 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions

More information

Fault location on power cables. Fault location on power cables

Fault location on power cables. Fault location on power cables Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 1. Introduction Fault location on communication and power cables

More information

AC Voltage- Pipeline Safety and Corrosion MEA 2015

AC Voltage- Pipeline Safety and Corrosion MEA 2015 AC Voltage- Pipeline Safety and Corrosion MEA 2015 WHAT ARE THE CONCERNS ASSOCIATED WITH AC VOLTAGES ON PIPELINES? AC concerns Induced AC Faults Lightning Capacitive coupling Safety Code Induced AC Corrosion

More information

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid. 1. Scope This specification defines the methods, the procedures and the requirements to verify the cables manufactured according to I.E.C. Specifications NPS361. 2. Standards All the standards referred

More information

Published in: Proceedings of the International Conference on Power Systems Transients (IPST 2009)

Published in: Proceedings of the International Conference on Power Systems Transients (IPST 2009) Aalborg Universitet Measurements for validation of high voltage underground cable modelling Bak, Claus Leth; Gudmundsdottir, Unnur Stella; Wiechowski, Wojciech Tomasz; Søgaard, Kim; Knardrupgård, Martin

More information

a Nexans company Catalogue 2014

a Nexans company Catalogue 2014 a Nexans company Catalogue 014 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated

More information

Licensed Electricians Practical Assessment (LEP)

Licensed Electricians Practical Assessment (LEP) Licensed Electricians Practical Assessment (LEP) Surname: Given Names: Date: Time: Location: Assessment Time (includes reading and preparation time): At the end of this time you will be asked to stop.

More information

INSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES

INSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES THE SAFE APPLICATIO OF CABLES The cables manufactured by S are only appropriate for the transmission of electric energy for supply and signalling purposes. First of all the valid construction and installation

More information

MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology

MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology For NERC Standard FAC-008 and FAC-009 Issued by: Dan Custer Reviewed by: Tom Mielnik Version 2.7 1 1.0 Scope: This document provides

More information

QN Male Connector Crimp/Solder Attachment for RG55, RG141, RG142, RG223, RG400

QN Male Connector Crimp/Solder Attachment for RG55, RG141, RG142, RG223, RG400 QN Male Connector Crimp/Solder Attachment for RG55, RG141, RG142, RG223, RG400 RF Connectors Technical Data Sheet PE44978 Configuration QN Male Connector 50 Ohms Straight Body Geometry Features Max Operating

More information

(other than Historical PD Tests) )

(other than Historical PD Tests) ) Diagnostic Testing Techniques for Distribution and Transmission Cables (other than Historical PD Tests) ) Experience with available techniques ICC Education Session - May 2011 Nigel Hampton, Josh Perkel

More information

Cable Sizing and Its Effect on Thermal and Ampacity Values in Underground Power Distribution

Cable Sizing and Its Effect on Thermal and Ampacity Values in Underground Power Distribution University of Kentucky UKnowledge Theses and Dissertations--Electrical and Computer Engineering Electrical and Computer Engineering 2016 Cable Sizing and Its Effect on Thermal and Ampacity Values in Underground

More information

Modelling Parameters. Affect on DER Impact Study Results

Modelling Parameters. Affect on DER Impact Study Results Modelling Parameters Affect on DER Impact Study Results Agenda Distributed Energy Resources (DER) Impact Studies DER Challenge Study Steps Lessons Learned Modeling Reverse Power Transformer Configuration

More information

Distribution Feeder Principles

Distribution Feeder Principles Distribution Feeder Principles Distribution Feeder Principles Introduction Electrical distribution is the final stage in the delivery of electricity to end users. The distribution system s network carries

More information

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER GROUNDED ELECTRICAL POWER DISTRIBUTION Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER .0 Conductors for Electrical Power Distribution For single-phase transmission of AC power or

More information