NEW TECHNOLOGY METER Current Loop, Signal or External Powered

Size: px
Start display at page:

Download "NEW TECHNOLOGY METER Current Loop, Signal or External Powered"

Transcription

1 NEW NEW TECHNOLOGY METER Current Loop, Signal or External Powered Replaces: DB0 or Any Switchboard Meter NTM- Pat. Pend., or Channels Build Your Own Part Number/Receive a Quote at: /configurator/nts/ FEATURES: *Automatic Tricolor Bar with Intensity Control * Digits at 0.5 & 0. ( or ) * Alarm with Run Time Stamp *Self Diagnostics *Isolated Serial I/O *USB/RS85 *Configurable Bar Direction (Up/Down/Center Zero)/Pointer *Only 00mW@5VDC! *Intensity Control * Math functions (+, -, x,,, X-Y tables, polynomials) *Averaging: None to 55 *Addressable: 8 Characters *Many Power Input Options (External Powered Models Only) * >0 Isolated Input Signals * Relays or O.C.T. (Open Collector Transistors) *-0mA/0V Output *Ethernet *μsd Flash Memory: GB *Lifetime Warranty Standard ANSI Switchboard Mounting on.75 Centers No Ø Barrel Hole Required DESCRIPTION: The New Technology Meter (NTM) series combines over 0 years of experience with the latest ASIC uc and ultra-efficient multicolor LED technology to bring you into the st century. The NTM external power series features over 0 signal conditioners ( square) which are housed in many industry standard packages to replace form, fit and function any analog or digital panel meter. If not, we'll make it! Our patented hardware and firmware gives you the highest reliability (we have a lifetime warranty) at the lowest cost, with features such as: automatic (programmable) tricolor display (like a traffic light); automatic signal fail detect (open or short); indication and serial transmission with run time stamp and units ID, isolated retransmission (-0mA), and universal power inputs (5-VDC or 90-65VAC). The NTM Series offers several math functions such as X-Y tables, polynomials and log-anti-log functions. The NTM signal and external power series also feature isolated USB, RS85 or ethernet, open collector transistors (/channel) and SPDT relays (/channel). You can tell us your custom needs and we'll make it (or might already have it)! The NTM- is available in a loop (-0mA), A.C. signal or external power version. The external power versions can accommodate relays, isolated DAC and power for the analog output (per channel), include >0 signal conditioners and isolated input power options, as well as ethernet and flash memory (μsd). Standard factory set color changes are: red: <0, >90%, yellow: <0, >80%, green: >0, <80% of F.S. Use digit, option 9 for custom configuration (you can change it with simple commands). NOW 0CFR50 APP. B & 0CFR & NEI (Cyber Security) Compliant *Buy Direct From OTEK *Free N.R.E. For Customs (Rules Apply) FAX: SCE E. TENNESSEE ST. TUCSON, AZ. 857 U.S.A.

2 NTM- THE PRODUCTS All New Technology products share the same innovative electronic circuit design. The difference between the models is their mechanical features (see Block Diagram and mechanical drawings). Some are displays only, some are single or multi channel, some can have relays, DACs, ethernet and flash memory, and some require an external power source. But all products contain the New Technology, which consumes less than % of comparable digitals (0-00mW for loop/signal powered versions) and approaches the power consumption of analog meters. WHAT CAN YOU DO WITH OTEK S NEW TECHNOLOGY? Note on Otek s Powerless Technology: If your signal cannot supply mw (~ 5V/mA), contact us or use external power models.. One Channel Models: -0, -, -B, -D, -F, -H, -L, -M, -N, -P, -S & -X: Implement any math function, X-Y table (5 point), polynomials (9 th order), offset, tare, zero, scale, log & anti-logarithmic to affect the unit s display at will. Some examples are: change the display & data using any combination as commanded by your algorithm, such as +/-/X/ / or set a variable or linearize the display using X-Y tables or polynomials. This works well for odd shape containers. You can also change the reading from F to C or K or compress/expand the display (and data out) using the log and antilog functions. In addition, you can change the factory default alarm pointers and colors or delete them. Zero & Span potentiometers are included for manual adjustment. Note: Models -D and -F have internal USB serial I/O that is not accessible to the customer. Contact Otek for access OTEK s New Technology series is only limited by your needs and imagination. Just give us a call at or us at sales@ otekcorp.com and give us the challenge to develop the best algorithm for your process.. Two Channel Models: -, -, - and -5 through -9 & -A: Note: Also available in models with or channels. Features include all those of the single channel models and each channel is 00% isolated from each other. In addition, you can add, subtract, multiply, divide, find the square root between channels. You can also use one channel to monitor/control the input signal and the second channel to indicate deviation, differential such as PID, alarm override or one channel setpoint can be used to control another channel function. You can also use one channel as a backup if the other channel becomes disabled or use them as volume & flow ( ) monitors/ controllers. The New Technology two channel models are also perfect as REM/RAD indicators/controllers (also see our RPM series with logantilog functions for radiation monitoring). Contact OTEK for algorithms and formulas or any idea you wish to share with our audiences via our Youtube or Facebook page posts.. Three Channel Models: -, -5, -7, -8 and -A: Note: Also available on channel models -5, -7 & -8. Otek s New Technology three channel models perform all the functions outlined in # and #. Further, one channel can indicate the input variable and the other two channels can be setpoint indicators/controllers (Hi, Hi-Hi, Low and Low-Low limits), or subject the input/ output to any mathematical function or algorithm such as PID or display the input vs. output and derivative, or switch scales when the input reaches a limit/band such as for flow-volume-pressure or temperature. Monitor Volts, Amps and Watts AC or DC or any of variables, including Hertz, lead/lag, power factor, peak/valley or for synchronizing of power lines with the bipolar (center zero) tricolor display. The New Technology series brings Process Automation Control (PAC) within your reach and affordability. These models are compatible with any DCS/SCADA system using their USB/RS85/Ethernet I/O options and allow for ease of interface with wireless systems.. Four Channel Models: -5, -7 and -8: The four channel models offer all of the functions outlined in #, # and #. However, with the additional channel available, the New Technology barmeters rival flatscreens with superior HMI/MMI functionality and ease of viewing/analysis of any combination of variables. For example, Volts/ Amps/Watts/Hertz or temperature/pressure/ph/humidity. The four channel models can also be used to monitor/control the product of the other variables, making them ideal for the petrochemical industry. Data Logging? Some models offer optional μsd memory to record /7 anything available via the serial I/O. Maximum capacity (and growing) is GB! REDUNDANT CONTROL: Because all channels are 00% isolated from each other, you can use any multi-channels model as a redundant controller. If you need the Democratic vote, algorithm, contact OTEK or see our Model TRC (Triple Redundant Controller) FAX: SCE E. TENNESSEE ST. TUCSON, AZ. 857 U.S.A.

3 NTM- Description, Notes & Order (Continued) Digit 5, Serial I/O & Memory: Settings: 8NN, 00-9,00 Baud, ASCII. LOOP/SIGNAL POWER ONLY Digit 5, Serial I/O: Option 0, USB: Complies 00% with V.0 and if digit 0, option is selected (USB powered) then digit 5 must be option 0. Digit 5, Option, RS85: Complies with industry standard and requires 5VDC@<mA and a terminating 0 Ohm resistor at first and last unit in the BUS. EXTERNAL POWER ONLY: Option 0, USB & Option, RS85 (see above), plus: Digit 5, Option Ethernet: Complies with 0 Base-T/00Base-TX RJ5 up to 9,00 Baud. Maximum power consumption is <00mA@5V (.5W). Digit 5, Options & : usd Flash Memory: Contact Otek for availability. Internal μsd flash memory with up to gigabytes capacity. You can store selected data at-will via serial command and download it as required. A GB card logging times per second can hold approximately year s worth of data. Need a Transmitter? See model NTY DIGIT 6, GRADE: Industrial Grade (Options 0 or I) is per these published specifications. Grades M and E per agreed specifications. Options E & M typically include an EMI/ RFI shield all around and filtered connectors to meet EPRI-TR-0-R (requiring ~ deeper case). OTEK will build to certain nuclear or MIL- Standards but testing and confirmation of compliance, if required, will be quoted extra. Option 0 is 9VO plastic, option I is an aluminium nickel plated case and cover; bezel face has black powder coat finish to Mil-Specs. The back cover is either black plastic or nickel plated aluminum. Typical Mil-Specs: 6, 6, 69, 90, 80, RTCA-60, I EEE, etc. Contact Otek for custom colors. NTM-X: Certified for Class I, Div., Groups B-G; EX & IECex: IM, Exd. Other Important Data: Math Functions: +, -, x,,, Polynomials to 9th order, 5 Point X-Y table, zero, offset, span and tare. You can add, subtract, multiply, divide (etc.) one channel to/from another channel and display the result in the other channel (i.e. V (Ch.)xA(Ch.)=W(Ch.). Signal Failure Alarm: Requires approximately minute of normal (midscale) operation for it to alarm the display and output the serial data after the signal (Powerless ) has ceased. Serial I/O: Setting: 8NN, 00-9,00 BAUD, 8 Character Address PID: Programmable (best with >dual channel models) automatic or manual with external 0K Ohm potentiometer (option 56). High Quality: No matter their size or number of channels all use the same (SV & V) firmware, hardware and commands. No matter their grade (Industrial, Mil-Spec, Nuclear) they all carry a lifetime warranty Industrial Grade Common Electrical Specifications Input & Display: *A/D: Accuracy, Linearity & Resolution: 0.5% of F.S. L.S.D. over entire temperature range of 0-60 C. Conversion Rate: 0/sec, Averaging: 0-55, zero, span, offset, tare, math functions, 5 point X-Y tables & polynomials (9 th ) *Bargraph: 5 Automatic Tricolor (R/Y/G) Segments *Digits: Four Full Digits ( & ). *Typical Power Consumption of Display: 0-00mW@.V-5V *Temperature Coefficient: +/-50PPM/ C *Operating Temperature: -0 to +60; Storage: -0 to +70 C *CCMR: >90dB@50-60Hz *Isolation: >500VDC to any other I/O & P.S. *Humidity: 5-95% RH non-condensing *Front Panel: NEMA. NEMA x on request. *Failed Signal Detect: ~ 0 seconds after > minute of F.S. *Calibration Check: years recommended. Note : See page of the master catalog for environmental specs vs. housing, bar length and digit size. Note : E and M grades are the same as Industrial unless otherwise specified FAX: SCE E. TENNESSEE ST. TUCSON, AZ. 857 U.S.A.

4 NTM- PUT SIGNAL SPECIFICATIONS (Digits 8 & 9) Industrial Grade Common Option 05-: Same as options 0 Electrical Specifications through 0. (Continued) AVAILABLE ON EXTERNAL POWER MODELS ONLY: Outputs: *Analog Output: Accuracy & Linearity: F.S.; 0. LSB, Range: -ma (max. load: <K Ohm). *Analog Output Temperature Coefficient: +/-50PPM C *Analog Output Isolation To All Other I/O & Power: >500VDC *Relays: Each/Channel (except -P { only} and NTY {/Ea}): SPDT Form C, A 0VAC/0VDC resistive load only, Contact Protection: 00VAC/DC on all contacts. Speed: +0mS (main loop). O.C.T. (Open Collector Transistors): VCE Max: 0VDC; Ice Max: 0mADC, Speed: +0mS (main Loop) Note : Relays & O.C.T. have P.O.D. (~00mS) and can be set for fail safe operation (normally on). Note : See Digit for default set points and User s Manual for command set via serial control. Note: All ± LSD and % full scale range unless noted. Option 00 & 7 For Loop Power Only: Option 00, -0mA Loop Powered: Burden: >V@mA, 5V@ 0mA; Range: -6mA; Accuracy & Linearity: ±0.5% of F.S., ± LSD. Option 7: 0-50mA Loop Powered: Burden: >V@0mA, 5V@ 50mA; Range: -50mA; Accuracy & Linearity: ±0.5% of F.S., ± LSD. Options 0 Through 8, A. C. Signal Powered Only: FUSE IT! Use external / ASB for Volts and 7 ASB for Amps. Important Notes: ) C.T. are sensitive and limited to the secondary (output) impedance. OTEK A.C. signal powered products present and input impedance of ~0. Ohms (~V@5A). Make sure your C.T. can drive a >0. Ohm load without saturating or losing linearity. Contact Otek for assistance. Best C.T. to use: >00:5 ratio. ) All inputs for Hz lines. Contact Otek for 00 Hz lines. Option 0, VAC (P.T.): Burden: 0. Ohm & <00mW; Range: 0-0V/0-00Hz; Accuracy & Linearity: ±0.5% of F.S. Best operating range: 90-0VAC to specifications. Option 0, 5 AMP A.C. (C.T.): Burden: <00mW; Range:.5-5A; Accuracy & Linearity: ±0.5% of F.S. Best range: - Amps. Note: Not available in -F case. Option 0, Watts A.C. (C.T. & P.T.): Not available on case -F. Range: >00<600W/50-60Hz; Accuracy & Linearity: ±0.5% of F.S. at 90-0VAC & -AAC. Best operating range: Watts. For 00 Hz lines, use option 0 and specify (0=00 Hz line) after the complete part number. Option 0, Hertz VAC: Not available on case -F. Range: >0V<0V & >0<00Hz; Accuracy & Linearity: ±0.5% of F.S. For 00 Hz lines, use option 0 and specify (0=00 Hz line) after the complete part number. PROPORTIONAL CONTROL? For proportional control, use a two (or more) channel model. Channel is powered by your signal and the display signal (using a -0mA out) to drive the Channel input. Channel s -0mA output allows you to control your generator. The result: Channel display your AC signal and Channel display it s -0mA output. Only Channel needs power for its analog output and/ or relays. Use part number NTM-(,,, 5, 6,7, 8, 9 or A)??-69-?-99). Note:? = any available option on Digits 5, 6 & 0 and specify (9=Ch signal power, Ch external power). Also see the new model NTI. VAC/DC Signal Power Only: Option 6, 7-0VAC/DC: Now you can monitor and control your AC line, UPS, battery bank or power supply from 7-0VDC/VAC, with only power from the signal. The NTM requires >0<80mW (~ma-0ma). Imagine the possibilities! Almost like analog (only signal wires), but with st century digital technology ready for your PAC/DCS/SCADA system. Scaling: 7-0VDC in = Digital Display & 5-00% bargraph with alarm pointers. See Digits & for custom calibration and scale. Accuracy & Linearity: 0.5% of full scale FAX: SCE E. TENNESSEE ST. TUCSON, AZ. 857 U.S.A.

5 NTM- Alarm Outputs (Signal Power): Open collector transistors () optional. See the ordering information on pages 9-, digit, option. For relays, contact Otek (custom). -0mA Analog Output: Custom, contact Otek (requires > watt from input signal). Option 7: 0-50mA Loop Power: See option 00 & 7 on page (first column). Option 8: 0-500mADC Signal Power: Calibration: 0-500mADC=0-500 & 5-00%. For other calibrations, use digit and specify. AVAILABLE ON EXTERNAL POWER ONLY Option 0: -0mA: The burden on the loop is only 0.5V@0mA (5 Ohm) and you can use the math functions for converting to flow, instantaneous or totalizer. Accuracy: +0.5% of F.S. digit Options -: VDC: Input impedance is Mega Ohms on all VDC ranges. Input impedance M Ω Range: Per Option digit Options 5 & 6, madc: Since the NTM is V full scale (,000 Counts) the Shunt resistors used are 00 Ohms for 0mA and 0 Ohm for 00mADC. Input impedance 5: 50Ω; 6: 5Ω; digit PUT SIGNAL SPECIFICATIONS (Digits 8 & 9) AVAILABLE ON EXTERNAL POWER MODELS ONLY Option 7, Watts DC: VZin: 0M Ω/AZin:.0Ω, 5W Range: W digit Option 8, Watts DC (VxV): VZin: M for both inputs Range: 0-V digit Option 9: Custom: Use this option to describe any custom input, scale or modification to the NTM and contact us for feasibility and cost. Options 0-, Volts RMS: Here we use a True RMS-DC Converter for accurate (+ 0.%) measurement of sine waves up to 0KHz. For 0-0KHz and SCR accuracy is + %. VRMS: Zin: MΩ Range; per options; digit Options 5-7, Amps RMS: We use a True RMS-DC Converter for accurate (+ 0.%) measurement of sine waves up to 0KHz. For 0-0KHz and SCR accuracy is + %. Zin: 5 (0.A): Ω; 6 (A): 0.Ω; 7 (5A): 0.0Ω; Range: Per option Accuracy & Linearity: ±0.5% of F. S. digit Options 8 & 0, Watts RMS: Here we use a True RMS-DC Converter for accurate (+ 0.%) measurement of sine waves up to 0KHz. For 0-0KHz and SCR accuracy is + %. Input impedances vs. range are the same as for VDC & madc ranges. Note: Always use P.T. and C. T. for options,, 0, and. Option 8 (VxVAC): Zin: MΩ for both inputs Range: V RMS digit Option 0 (0VACx5AAC C.T.): Zin: M for V & 0.0Ω for I Range: 0-750W digit Note: Option 0 (0V/5A) includes the shunt (0.0 Ohms/0W) on connector only for 5A C.T. Options -, Hertz: We use an F-V to accept frequencies up to 0KHz and amplitudes from -00V peak or dry contact or open collector transistor (O.C.T.). For 50 to 0 Hz power line frequency measurement, use Option #. Option (0KHz/5V Logic): Zin: M Range: 0-0KHz digit Option (0V, 0-00Hz): Zin: M Range: 50-50VC/0-00Hz digit Option (0V, 0-00Hz): Zin M; Range: 00-60V/0-00Hz digit Option (0V, 500 Hz): Zin: M Range: 50-50V/00-500Hz digit FAX: SCE E. TENNESSEE ST. TUCSON, AZ. 857 U.S.A.

6 NTM- Option 5: Strain-Gage (>00 < K Ohm): These are typically "Monolithic" S-G that require constant voltage (preferably) excitation. We use.096v for high stability and accuracy. Use option 9 and specify your S-G sensitivity and the NTM display at Zero and Full Scale. Excitation:.096V, 50 PPM/ C Range: ±00-K Ω digit Note on S-G: Some S-G offer +/- VDC or -0mA condition output. Use Option 9 and specify. Option 7: RTD (PT00): Note: For options 7 & 8 you can change C to F and RTD type via serial port. We excite your, or wire RTD with 00μA to avoid the "self heating" effect. The range of the NTM is the same as your RTD typically C to C ( F). You can place the decimal point at will (typically to The PT00 has a temperature coefficient of Ohms/Ohm/ 0 C. (For legacy TC (known as ANSI 9) contact OTEK and use Option "9". Accuracy: +0.5% of F.S. digit, plus sensor's error. Note: For wire, jump - S to -E and +S to +E. For wire only jump -S to -E. PUT SIGNAL SPECIFICATIONS (Digits 8 & 9) AVAILABLE ON EXTERNAL POWER MODELS ONLY Option 8: RTD (PT000): Same as PT00 except it is 000 Ohms at 0 0 C instead of C. The same technique is used for copper RTD (0 Ohm), contact OTEK. Same connection as Option 7 apply. Accuracy: +0.5% of F.S. digit, plus sensor's error. Note: For long distances (> 00 )use a -0mA transmitter such as our model NTY from our New Technology series. Option 50: Thermocouple (Type J): This TC has a range of -0 to C ( F). Its color is white (+) and Red (-), cold junction (CJ) is at the connector. Make sure the connections from the NTM and your TC are as close to the NTM entrance as possible to avoid errors. If you short out the NTM's +TC & -TC together, the NTM will read the ambient temperature at the junction due to its built-in C.J.C. Note: You can change C to F and TC type via serial port. Accuracy: + 0 F.S. of signal input. Option 5: TC (Type K): This is yellow (+) and red (-) and has a range of C ( F). The same notes as Option 50 apply. Accuracy: + 0 F.S. of signal input. Option 5: TC (Type T): This blue (+) and red (-) TC has the range of C ( F). Same notes as Option 50 apply. Accuracy: + 0 F.S. of signal input. Option 5: ph (Acidity): We use a FET input (0 5 ) amplifier and calibrate the NTM for ph using the Industry's standard + mv = + 7pH co-efficient. Note: Not temperature compensated, contact OTEK for auto temperature compensation. Accuracy: +0.5% of F.S. digit Option 5: ORP (Oxygen Reduction Potential): Our FET amplifier (0 9 ) accepts the industry standard 000mV F.S. of the probe and the NTM displays it in % (0-00.0%). Accuracy: +0.5% of F.S. digit Option 55: %RH: This conditioner is designed to interface to a typical (capacitance type) - pf/% of RH made by several manufacturers. Use Option "9" and contact OTEK to specify your sensor's specifications. Accuracy: + 0.5% RH of signal input, digit. Option 56 Resistance (0-0K Ohm): Want a simple -0mA transmitter? Just connect a 0K Ohm (others on request) potentiometer to the NTM and control any -0mA input valve, motor, transducer, etc. Accuracy & Linearity is ±0.5% of F. S. digit. Standard Calibration: 0-0K Ohms=-0mA. Use option #9 and specify your calibration. Ideal for linear transducers FAX: SCE E. TENNESSEE ST. TUCSON, AZ. 857 U.S.A.

7 NTM- Option 57, 0-50mA Range: 0 Ohms input resistance Digit Option 58: Serial Input Remote Display/Controller: Here you can use the unit as a remote display/controller with modified ASCII to alpha-numeric display for DCS SCADA, PLC systems. See the user s manual for simple commands to use the NTM in PAC applications. Digit 0 (Power Input): LOOP & SIGNAL POWER ONLY: Digit 0, Option 0, Powerless, No Power Required: The Input Fail detect/alarm (patent pending) flashes the display PT FAIL ( ) and transmits this serial message for ~0 seconds, after which it will cease. This feature is available in all Powerless models. If desired on powered models, use option 9 on Digit and specify input fail detection. Signal Fail Requirement: Unit must be On for at least minute at >50% of full scale for it to operate. EXTERNAL POWER ONLY: Digit 0, Option, USB Powered: The NTM series requires >.<.5 Watts/Channel (worst case, fully loaded) meaning that you can power it through the USB port, but this option eliminates the isolation from USB to input signal. Analog output remains isolated contact OTEK for more details or use options -. Description, Notes & Order (Continued) Digit 0 (Power Input): (Continued) EXTERNAL POWER ONLY: Digit 0, Option, 5VDC: 5VDC is used to drive the relays (<50mA/relay) and/or the DAC via internal isolated 5-0VDC-DC (<00mA). If you order relays and analog out, you will need ~00mA/channel. This option is also isolated from the input signal. Digit (Control Outputs): EXTERNAL POWER ONLY: Digit 0, Option, 7-VDC: Same as option but with wide input range of 7-VDC. Efficiency: >75%. Digit 0, Option, 90-65VAC: This option accepts 50-60Hz. For 00-00VDC or 00 Hz, use Digit 0, option 9 and specify. Efficiency: >70%. Digit, Control Outputs: Options, or 5: Open Collector Transistors (O.C.T.): They are NOT isolated from each other (common emitter) but are isolated between channels and can sink a maximum of 0 ma and sustain a maximum of 0VCE (the O.C.T. are normally used to drive S.S.R). When you order option, or 6 (Relays), we use the O.C.T. to drive the relays. NOTE: You can use the internal isolated 5VDC power to drive loads with the O.C.T. Total maximum current available is 50mADC. Digit (Control Outputs): Digit, Options, or 6: Relays: are S.P.D.T. (C) and can switch maximum resistive loads of 0 VAC or 0 VDC. They include 00V varistors at their contacts. Inductive loads must be attenuated by the user. Digit (Control Outputs): (Continued) AVAILABLE ON EXTERNAL POWER ONLY AUTOMATIC BAR COLORS: Limits/Colors Factory default (% of Full Scale): Also see digit. Low-Low Limit (<0%): Red Bar, OCT/K ON Low Limit (<0%): Yellow Bar, OCT/K ON High Limit (>80%): Yellow Bar, OCT/K ON Hi-Hi Limit (>90%): Red Bar, OCT/K ON Safe Area (>0<80%): Green bar will follow signal input and if outside the limits, it will change its color to the limit s color (yellow or red). For other configurations, use option 9 on Digit (field configurable). Max power consumption per relay: 50mA@5VDC (0.5W). See Digit FAX: SCE E. TENNESSEE ST. TUCSON, AZ. 857 U.S.A.

8 NTM- Digit (Control Outputs) {Continued}: AVAILABLE ON EXTERNAL POWER ONLY See commands in user s manual to customize your display colors. External Control: You can control the O.C.T./Relays via the serial port at will with simple commands. They don t have to be assigned to the bar colors/set points, but are by default. Notes:. Digit is governed by Digit 7 (# of Channels) & Digit (Housing). Reason: Digit can NOT have more channels than permitted by Digit 7 or it cannot fit in the housing (Digit ). Important Note on A.C. Powerless The NTM, UPM & NT Series can extract energy from your A.C. signal to power itself and opto isolated serial, optional O.C.T. (Digit, options,, 5 or 7), and to power the optional -0mA output (Not 0-mA out) from a wide input range. External power is required to power the optional relays (Digit, options,, 6 & 8) (00mW each). If you need relays, either use the external powered options on Digits 8 & 9 (, 7, 0 or ) and the Digit 0 power input options (-) or use Powerless options 0-0 on Digits 8 & 9 and Power Input option 09 (custom) on Digit 0 and specify (09=Power for relays and DAC). Result: The signal will power the instrument and will include our patented Signal Fail Detection & Alarm. The relays and analog output are powered by the external power option (all 00% isolated). Description, Notes & Order (Continued) Digit (Analog /Power Output): AVAILABLE ON EXTERNAL POWER ONLY Digit, Analog Output, Options, or 5: This isolated output is factory set to follow the input (0-F.S. in=- 0 out) but can also be set for other outputs or serially controlled by simple commands via the serial port. For other outputs, use option 9 and specify, including reverse scale (-0=0-), bipolar and PID. Power consumption: 00mA@5VDC (W). Accuracy & Linearity: ±0.5% of full scale. Digit, 0 VDC Out, Options, or 6: Use this option to power your -0mA transmitter or other transducer. Maximum current is 5mADC. It s isolated and is the same power source we use for -0mA out. Power consumption: 00mA@5VDC (W)/ channel.. This digit is governed by digits (Housing) & 7 (# of Channels). Reason: Digit cannot have more outputs than input channels (Digit 7), which is governed by Digit (Housings). Digit (Scale Plate): Digit, Scale Plate: Option 0 is a standard scale plate that reads 0-00%. Use option 9 for custom printing and contact Otek. Digit (Range/Calibration): 0= Factory Default: 0-Full Scale Input=0-00% bar and digits. Colors: <0>90%: Red; <0>80%: Yellow; >0<80%: Green. Use Option 9 (custom) and contact Otek. Also see Control Outputs (Digit ). Display Default: 0-full scale= 0-00%. You can program it for single pointer, or three or five bars via the serial port. ABOUT OUR PUT FAIL DETECTION Only available on Powerless models. While in normal operation, we store excess energy and use it to power the NTM if and when the signal fails (post mortem). Need a Transmitter? See model NTT FAX: SCE E. TENNESSEE ST. TUCSON, AZ. 857 U.S.A.

9 NTM- LOOP POWER VERSION ORDERG FORMATION 5--7 *Grades E, M & 9 might require an N.R.E. fee., or CHANNEL LOOP POWERED DISPLAY OTEK S HI-QTBS/HI-Q ( x ) Switchboard Case NTM- NTM- SERIAL I/O () 0...USB...RS Custom (Contact OTEK) GRADE & CASE 0...Industrial & Plastic I...Industrial & Metal...Industrial & Plastic NEMA X...Industrial & Metal NEMA X M...To Mil-Spec & Metal (Contact OTEK) E...To Epri-Nuclear & Metal (Contact OTEK) 9...Custom (Contact OTEK) # OF CHANNELS (, )...One...Two...Three 9...Custom (Contact OTEK) RANGE/CALIBRATION 0...Standard 9...Custom (Contact OTEK) SCALE PLATE 0...Standard (0-00%) 9...Custom (Contact OTEK) ANALOG/POWER OUTPUT 0...None CONTROL OUTPUTS 0...None POWER PUT 0...Powerless (No Power) PUT SIGNAL mA, All Channels=Input, Loop Power mA, All Channels=Input, Loop Power Build Your Own Part Number/Receive a Quote at: /configurator/nts/ NOTE: Please READ BEFORE building part number:. USB I/O is powered by VUSB. RS85 requires 5V@~mA.. Otek will build to certain nuclear or MIL-Standards but testing and confirmation of compliance, if required, will be quoted as a separate line item.. Multi-channel input signal is the same for all channels.. Channel is outer, is middle, is inner FAX: SCE E. TENNESSEE ST. TUCSON, AZ. 857 U.S.A.

10 NTM- SIGNAL POWER VERSION ORDERG FORMATION 5--7 NOTE: Please READ BEFORE building part number:. If Digit 7 is option, then Digits 8 & 9 can only be options 0-0, 09 or 6. If digit 7 is option, then Digits 8 & 9 can only be options If digit 7 is option, then Digits 8 & 9 can be 0-., or CHANNEL SIGNAL POWERED DISPLAY NTM- SERIAL I/O () 0...USB...RS Custom (Contact OTEK) GRADE & CASE 0...Industrial & Plastic I...Industrial & Metal...Industrial & Plastic NEMA X...Industrial & Metal NEMA X M...To Mil-Spec & Metal (Contact OTEK) E...To Epri-Nuclear & Metal (Contact OTEK) 9...Custom (Contact OTEK) OTEK S HI-QTBS/HI-Q ( x ) Case RANGE/CALIBRATION 0...Standard 9...Custom (Contact OTEK) SCALE PLATE 0...Standard (0-00%) 9...Custom (Contact OTEK) ANALOG/POWER OUTPUT 0...None CONTROL OUTPUTS 0...None POWER PUT 0...Powerless (No Power) NTM- *Grades E, M & 9 might require an N.R.E. fee. # OF CHANNELS (,6)...One...Two...Three 9...Custom (Contact OTEK) PUT SIGNAL (,, 5) 0...Volts A.C., All Channels, Signal Power Amps A.C., All Channels, Signal Power 0...Watts A.C., All Channels, Signal Power 0...Hertz A.C.V., All Channels, Signal Power 05...Mixed Channel...VAC Ch., AAC Ch.,Signal Power 06...Mixed Channel...VAC Ch., WAC Ch., Signal Power 07...Mixed Channel...VAC Ch., Hz Ch., Signal Power 08...Mixed Channel...AAC, Ch., WAC Ch., Signal Power 09...Custom (Contact OTEK) 0...Mixed Channel...V Ch., A Ch., W, Ch. Signal Power...Mixed Channel...V Ch., A Ch., Hz Ch. Signal Power...Mixed Channel...V Ch., W Ch., Hz Ch. Signal Power...Mixed Channel...A Ch., W Ch., Hz, Ch. Signal Power Volts A.C./D.C., All Channels,Signal Power mADC, All Channels, Signal Power Build Your Own Part Number/Receive a Quote at: / configurator/nts/ NOTE:. USB I/O is powered by VUSB. RS85 requires 5V@~mA.. Otek will build to certain nuclear or MIL-Standards but testing and confirmation of compliance, if required, will be quoted as a separate line item.. For other ranges (i.e. 00 Hz) use option 9 and specify. 5. Multi-channel input signal selected is the same for all channels. 6. Channel is outer, is middle, is inner FAX: SCE E. TENNESSEE ST. TUCSON, AZ. 857 U.S.A.

11 NOTE: Please READ BEFORE building part number:. If digit 0 is option, then digit 5 must be option 0 or. USB I/O is powered by VBUS (ma). RS85 requires 5V@~mA.. If Digit 7 is option, then Digits and can only be options 0- or 9. If digit 7 is option, then Digits and can only be options 0- or 9.. The number of outputs (Digits and ) cannot exceed the number of channels (Digit 7) and cannot exceed the number of Input Signals (Digits 8 & 9). NTM- ORDERG FORMATION 5--7 SERIAL I/O () 0...USB...RS85...Ethernet...USB & μsd Memory (Pending)...RS85 & μsd Memory (Pending) 9...Custom (Contact OTEK) GRADE & CASE 0...Industrial & Plastic I...Industrial & Metal...Industrial & Plastic NEMA X...Industrial & Metal NEMA X M...To Mil-Spec & Metal (Contact OTEK) E...To Epri-Nuclear & Metal (Contact OTEK) 9...Custom (Contact OTEK) *Grades E, M & 9 might require an N.R.E. fee., OR CHANNEL EXTERNAL POWERED CONTROLLER # OF CHANNELS (,, 5)...One...Two...Three 9...Custom (Contact OTEK) OTEK S HI-QTBS/HI-Q ( x ) Case NTM- - - RANGE/CALIBRATION 0...Standard 9...Custom (Contact OTEK) SCALE PLATE 0...Standard (0-00%) 9...Custom (Contact OTEK) ANALOG/POWER OUTPUT (, ) 0...None...CH....-0mA Out...CH....0V Out...CH. &...-0mA Out...CH. &...0V Out 5...CH., &...-0mA Out 6...CH., &...0V Out 9...Custom (Contact OTEK) CONTROL OUTPUTS (, ) 0...None...CH....O.C.T. ()...CH....Relays ()...CH. &...O.C.T. (8)...CH. &...Relays (8) 5...CH., &...O.C.T. () 6...CH., &...Relays () 9...Custom (Contact OTEK) NTM- PUT SIGNAL (, 6, 7) See Page and enter option number for Digits 8 & 9. POWER PUT ()...Non-Isolated USB...Isolated 5VDC...Isolated 7-VDC...Isolated 90-65VAC 9...Custom (Contact OTEK) NOTE: Please READ BEFORE building part number:. Otek will build to certain nuclear or MIL-Standards but testing and confirmation of compliance, if required, will be quoted as a separate line item. 5. Channel is outer, is middle, is inner. 6. For 00 Hz line, use option 9, 69 or 79 and specify input. Peak & Hold to 50KHz function on request mV shunt not included FAX: SCE E. TENNESSEE ST. TUCSON, AZ. 857 U.S.A.

12 MODEL NTM- DIGITS 8 & 9 PUT SIGNAL ORDERG FORMATION 5--7 AVAILABLE ON EXTERNAL POWER MODELS ONLY NTM- PUT SIGNAL PUT SIGNAL, All channels same input. (, 6, 7) ma F.S....00mV DC F.S....VDC F.S....0VDC F.S....00VDC F. S mADC F. S mADC F.S. 7...Watts DC (VxA) F.S. 8...Watts DC (VxV) F.S. 9...Custom (Contact OTEK) V RMS F. S....V RMS F.S....0V RMS F.S....50V RMS F.S V RMS F.S A RMS F.S. 6...A RMS F.S A RMS F.S. 8...W RMS (VxVAC) F.S. 0...W RMS (0Vx5A AC) F. S....Hertz (0KHz/5V Logic) F.S....Hertz (0VAC/0-00 Hz) F.S....Hertz (0VAC/0-00 Hz) F.S....Hertz (0VAC/500 Hz) F.S. 5...Strain-Gage ( 00<K Ohm) 7...RTD (PT00) 8...RTD (PT000) 50...TC (Type J) 5...TC (Type K) 5...TC (Type T) 5...pH (0-.00) 5...ORP (0-000mVDC) 55...% RH (Specify Sensor) 56...Resistance (0-0K 0-50mA F.S. None (Serial Input Remote Meter) Build Your Own Part Number/Receive a Quote at: / configurator/nts/ MIXED PUT SIGNALS ( CHANNELS) 60...Ch.: V; Ch. A (. Ω) RMS 6...Ch.: 0V; Ch.: A (. Ω) RMS 6...Ch.: 00V; Ch.: A (. Ω) RMS 6...Ch.: 00V; Ch.: 50mV RMS 6...Ch.: 50V; Ch.: 5A (.0 Ω) RMS 65...Ch.: 50V; Ch.: 5A (.0Ω) RMS 66...Ch.: 50V; Ch.: 00Hz (0 V Line) RMS 67...Ch.: 50V; Ch.: 00 Hz (0V Line) RMS 68...None, Serial Input Only 69...Custom (Contact OTEK) MIXED PUT SIGNALS ( CHANNELS) 70...Ch.: V; Ch.: A (. Ω); Ch.: W DC 7...Ch.: 0V; Ch.: A (. Ω); Ch.: W DC 7...Ch.: 00V; Ch.: A (. Ω); Ch.: W DC 7...Ch.: 00V; Ch.: 50mV; Ch.: W DC 7...Ch.: 50V; Ch.: 5A (.0 Ω); Ch.: W RMS 75...Ch.: 50V; Ch.: 5A (.0Ω); Ch.: W RMS 76...Ch.: 50V; Ch. : 5A (.0Ω); Ch.: 00Hz RMS 77...Ch.: 50V; Ch. : 5A (.0Ω); Ch.: 00 Hz RMS 78...None, Serial Input Only 79...Custom (Contact OTEK) NOTES:. The number of outputs (Digits and ) cannot exceed the number of channels (Digit 7) and cannot exceed the number of Input Signals (Digits 8 & 9). 6. For 00 Hz line, use option 9, 69, 79 or 89 and specify input. Peak & Hold to 50KHz function on request mV shunt not included FAX: SCE E. TENNESSEE ST. TUCSON, AZ. 857 U.S.A.

13 NTM- MECHANICALS AND TYPICAL CONNECTIONS.5" 0.5"R > ".9 ( PL.).8".75" (85.MM) SQR..50"D SEE NOTE 5 ( PL).5" C L CONNECTORS & ADJUSTMENT AREA "H X.5"W CENTERED OR FRONT VIEW SIDE VIEW REAR VIEW F#87TBSME PREFERRED PANEL CUTOUT: STD. NEMA :.0. ANSI "(.75") CASE CAN ALSO BE MOUNTED / D PANEL CUTOUT (9x9mm).. CONNECTORS AND.75" STUDS SPACG MEET ANSI9. STANDARD FOR SWITCHBOARD METERS. J FALLS WITH EXISTG "BARREL" CUTOUT.. WIRE: 6-6GA. SHIELDED VERSIONS WILL EXTEND ~ BEHD THE PANEL. 5. METAL VERSION HAS #8-X / MOUNTG STUDS; PLASTIC HAS #-0X/ MOUNTG STUDS. I V A NEW TECHNOLOGY METER BLOCK DIAGRAM/CHANNEL CURRENT LOOP (LOOP POWER) AC/DC V, A,W, Hz (SIGNAL POWER) SIGNAL CONDITIONERS (EXTERNAL POWER) CONTROLLER/DISPLAY ONLY DISPLAY ONLY DISPLAYS, CPU, SIGNAL DETECT, KEEP ALIVE, ISOLATORS FOR ALARMS, SERIAL I/O, PWM, / RS 85 USB RELAYS O.C.T ANALOG OUT ETHERNET USB/85 FLASH MEMORY 5- VDC VAC POWER SUPPLY O.C. T. () RELAYS () -0mA OUT () 0V OUT () RS85 USB/ ETHERNET POWER PUT SEE CUSTOMIZED USER S MANUAL FOR SPECIFIC CONNECTIONS AT: /configurator/nts/ : VCC : GND. : -LOOP SIGNAL : +LOOP SIGNAL LOOP POWER: 5 V.P./USB POWER (NO CONTROL OUT) USB STA SERIAL I/O NOTES: LOOP POWER NEEDS NO VCC OR GROUND. SERIAL IS COMMON TO ALL CHANNELS. USE EITHER USB OR ST FAX: STC : VCC : GND. : -LOOP SIGNAL : +LOOP SIGNAL A C A C RS85 (ST): : +5 V D.C. : D- (B) : D+ (A). GROUND RS85 ST STB B B : VCC : GND. : -LOOP SIGNAL : +LOOP SIGNAL TYPICAL CONNECTIONS SIGNAL POWER WARNG! PUT (STA, B & C): H.V. : V A.C. HIGH THIS : V A.C. LOW STC CH C SECTION. : A A.C. HIGH. A A.C. LOW DO NOT TOUCH STB CH B ST RS85 (ST): : +5 V D.C. : D- (B) : D+ (A) USB STA CH A. GROUND SERIAL I/O NOTE: SERIAL IS COMMON TO ALL CHANNELS. USE EITHER USB OR ST. NOTE: & POTS. ON REQUEST ONLY. -- SCE 97 RS85 (ST): : +5 V D.C. : D- (B) : D+ (A). GROUND ST5, DAC/0V OUT: : +LOOP/0V OUT : -LOOP/0V OUT : CUSTOM PUT EXTERNAL POWER (WITH CONTROL OUTPUTS) CHANNEL A ST5A DAC/0V OUT SEE TEXT FOR CONNECTIONS STA STA SERIAL I/O ST USB ST5C DAC/0V OUT STC STC ST CHANNEL C ST5B DAC/0V OUT STB NOTE: SERIAL IS COMMON TO ALL CHANNELS. POWER PUT IS COMMON & ISOLATED TO ALL CHANNELS. USE EITHER USB OR ST. ALL CHANNELSHAVE THE SAME CONNECTIONS STB CHANNEL B STA, B & C, PUT SIGNALS: SEE TEXT ON MANUAL STA, B & C, RELAYS OR O.C.T.: : K N.O./5V OUT FOR O.C.T. : K COM./C. EMM. FOR O.C.T. : K N.C./O.C.T. : K N.O./O.C.T. 5: K COM./O.C.T. 6: K N.C./O.C.T. 7: K N.O. 8: K COM. 9: K N.C. 0: K N.O. : K COM : K N.C. MAX 5 V OUT: 50mA. 06 E. TENNESSEE ST. TUCSON, AZ. 857 U.S.A. ST, POWER : : V+/V A.C. H : V-/V A.C. L

NEW TECHNOLOGY METER Current Loop, Signal or External Powered

NEW TECHNOLOGY METER Current Loop, Signal or External Powered NEW NEW TECHNOLOGY METER Current Loop, Signal or External Powered Replaces: Any 2 x 3 x.5 Flat Pack Pat. Pend. 2 3 Build Your Own Part Number/Receive a Quote at: / configurator/nts/.6 NO PANEL CUT OUT.

More information

NEW TECHNOLOGY METER Current Loop, Signal or External Powered

NEW TECHNOLOGY METER Current Loop, Signal or External Powered NEW NEW TECHNOLOGY METER Current Loop, Signal or External Powered Replaces: Any ¼ D Meter or A.P. M. Pat. Pend..78 (96), or Channels.78 (96) Build Your Own Part Number or Receive a Quote at: /configurator/nts/

More information

NEW TECHNOLOGY METER Current Loop, Signal or External Powered

NEW TECHNOLOGY METER Current Loop, Signal or External Powered NEW NEW TECHNOLOGY METER Current Loop, Signal or External Powered Replaces: Bailey 775, Foxboro 57 or Any 6 or 7 x.785 Meter Pat. Pend.,, or Channels Note: The only difference between NTM-7 and is the

More information

NEW TECHNOLOGY METER Current Loop, Signal or External Powered

NEW TECHNOLOGY METER Current Loop, Signal or External Powered NEW NEW TECHNOLOGY METER Current Loop, Signal or External Powered Replaces: DB40 or Any 4 Switchboard Meter >0 Viewing Distance! Pat. Pend. SEE NTM-N FOR SEGMENT Build Your Own Part Number or Receive a

More information

NEW TECHNOLOGY METER Current Loop, Signal or External Powered

NEW TECHNOLOGY METER Current Loop, Signal or External Powered NEW NEW TECHNOLOGY METER Current Loop, Signal or External Powered Replaces: Sigma VMI, Dixson or Any 8 x 7 x 1mm (1.9 x 5.7 ) Meter NTM- Pat. Pend. FEATURES: *Automatic Tricolor Bar with Intensity Control

More information

NEW TECHNOLOGY METER Current Loop, Signal or External Powered

NEW TECHNOLOGY METER Current Loop, Signal or External Powered NEW NEW TECHNOLOGY METER Current Loop, Signal or External Powered Replaces: Any Explosion Proof Meter Pat. Pend. 3.9 Need IRDA to USB Translator? Order Model IR/USB. ¾ NPT 4.3 (110) Meets EX & ECex1M2

More information

SAFE SSAM-N CYBER SECURITY

SAFE SSAM-N CYBER SECURITY NEW SAFE CYBER SECURITY 100% ANALOG METER REPLEMENT FOR SIGNAL & EXTERNALLY POWERED: Current Loops, (V, A, W, Hz) and DC (V, A & W) CLASS, APP. B & MIL/AEROSPE GRADES AVAILABLE SSAM-N (Patent Pending)

More information

AUTOMATIC TRI-COLOR ISOLATED TRIPLE BAR-DIGITAL CONTROLLER WITH USB/232/485/ETHERNET I/O & MICRO CARD FOR NUCLEAR, MIL-STD & INDUSTRIAL USE

AUTOMATIC TRI-COLOR ISOLATED TRIPLE BAR-DIGITAL CONTROLLER WITH USB/232/485/ETHERNET I/O & MICRO CARD FOR NUCLEAR, MIL-STD & INDUSTRIAL USE NEW! PRELIMINARY AUTOMATIC TRI-COLOR ISOLATED TRIPLE BAR-DIGITAL CONTROLLER WITH USB//85/ETHERNET I/O & MICRO CARD FOR NUCLEAR, MIL-STD & INDUSTRIAL USE MODEL TBD FEATURES: * Ea. isolated bit A/D with

More information

AUTOMATIC, MANUAL OR DCS/PAC/SCADA NEW TECHNOLOGY 4-20mA TRANSMITTER FOR NUCLEAR-MILITARY-INDUSTRIAL USES

AUTOMATIC, MANUAL OR DCS/PAC/SCADA NEW TECHNOLOGY 4-20mA TRANSMITTER FOR NUCLEAR-MILITARY-INDUSTRIAL USES NEW PRODUCT AUTOMATIC, MANUAL OR DCS/PAC/SCADA NEW TECHNOLOGY 0mA TRANSMITTER FOR NUCLEARMILITARYDUSTRIAL USES MODELS NTT FEATURES: * Fine Resolution Potentiometer * High Accuracy/Resolution Output * Remote

More information

WORLD S SMALLEST BARGRAPH METER LOOP OR AC/DC POWERED > 30 INPUT SIGNAL CONDITIONERS

WORLD S SMALLEST BARGRAPH METER LOOP OR AC/DC POWERED > 30 INPUT SIGNAL CONDITIONERS New! WORLD S SMALLEST BARGRAPH METER LOOP OR AC/DC POWERED > 3 INPUT SIGNAL CONDITIONERS Model SBM FEATURES: *3 Colors: red, green or yel. * Dual Independent A/D (For Bar & Digital) *Loop Powered (4-2mA)

More information

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-D. D. C. SIGNAL POWERED FOR V, 4-20 & madc

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-D. D. C. SIGNAL POWERED FOR V, 4-20 & madc TO BE DISCONTUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-D NEW D. C. SIGNAL POWERED FOR V, 4-20 & madc (& EXTERNALLY POWERED FOR OTHER SIGNALS) 3 1/2" ANALOG METER REPLACEMENT *>20 Signal Conditioners

More information

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-F

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-F TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-F NEW Signal Powered or 5-28VDC Powered FLAT PACK PANEL METERS NEED NO PANEL CUT OUT > 40 INPUT SIGNALS ACCEPTED MODEL FPM FEATURES: 4

More information

NEW. MODEL ACL Pat. Pend. WORLD'S FIRST POWERLESS TM A.C. LOOP TRANSMITTER, CONTROLLER FOR: VOLTS-AMPS-WATTS-HERTZ

NEW. MODEL ACL Pat. Pend. WORLD'S FIRST POWERLESS TM A.C. LOOP TRANSMITTER, CONTROLLER FOR: VOLTS-AMPS-WATTS-HERTZ NEW WORLD'S FIRST POWERLESS TM A.C. LOOP TRANSMITTER, CONTROLLER FOR: VOLTS-AMPS-WATTS-HERTZ MODEL ACL Pat. Pend. FEATURES: Powered By Your P.T. or C.T.! No Power Supply Required Only 2 Wires to Connect

More information

NEW MODEL SEB AUTOMATIC TRICOLOR SWITCHBOARD BARGRAPH FOR MIL-SPEC, NUCLEAR & HI-REL INDUSTRIAL USES WITH > 20 INPUT SIGNAL CONDITIONERS

NEW MODEL SEB AUTOMATIC TRICOLOR SWITCHBOARD BARGRAPH FOR MIL-SPEC, NUCLEAR & HI-REL INDUSTRIAL USES WITH > 20 INPUT SIGNAL CONDITIONERS NEW AUTOMATIC TRICOLOR SWITCHBOARD BARGRAPH FOR MIL-SPEC, NUCLEAR & HI-REL INDUSTRIAL USES WITH > 20 INPUT SIGNAL CONDITIONERS MODEL SEB FEATURES: New: VDC/A.C. Signal Powered (No power supply required)

More information

1/8 DIN BAR-DIGITAL METER/CONTROLLER *AUTOMATIC TRICOLOR BAR *RELAYS/DAC/SERIAL *NUCLEAR *MIL-SPEC * INDUSTRIAL GRADES

1/8 DIN BAR-DIGITAL METER/CONTROLLER *AUTOMATIC TRICOLOR BAR *RELAYS/DAC/SERIAL *NUCLEAR *MIL-SPEC * INDUSTRIAL GRADES TO BE DISCONTINUED /06. FOR REPLACEMENT, CLICK NTM0 or NTMB NEW /8 DIN BARDIGITAL METER/CONTROLLER *AUTOMATIC TRICOLOR BAR *RELAYS/DAC/SERIAL *NUCLEAR *MILSPEC * INDUSTRIAL GRADES MODEL BDM FEATURES: Proven

More information

BARGRAPH/CONTROLLER/REMOTE DISPLAYS Direct Replacements for Ametek (Dixson) BE051 & BE101Models >30 INPUT SIGNAL CONDITIONERS

BARGRAPH/CONTROLLER/REMOTE DISPLAYS Direct Replacements for Ametek (Dixson) BE051 & BE101Models >30 INPUT SIGNAL CONDITIONERS TO BE DISCONTINUED /06. FOR REPLACEMENT MODEL, CLICK HERE: NTM-P BARGRAPH/CONTROLLER/REMOTE DISPLAYS Direct Replacements for Ametek (Dixson) BE05 & BE0Models >0 INPUT SIGNAL CONDITIONERS HI-Q0 If you don't

More information

UNIVERSAL DPM/COUNTER/TIMER Current Loop, Signal or External Powered

UNIVERSAL DPM/COUNTER/TIMER Current Loop, Signal or External Powered NEW UNIVERSAL DPM/COUNTER/TIMER Current Loop, Signal or External Powered Replaces: DB40 or Any 4 Switchboard Meter UPM-3 PATENT #9,054,721 B1 1, 2 or 3 Channels SECTIONS: DPM: P. 2-7 CTR: P. 8-13 REM:

More information

Absolute Process Instruments

Absolute Process Instruments Strain Gauge, Load Cell, Bridge Current Switches and Transmitters Amplify, alarm strain gauge sensor signals Economical sensors for current out-of range alarms or monitoring current levels APD 1520 APD

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading

More information

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

FC-33, DC SELECTABLE SIGNAL CONDITIONER

FC-33, DC SELECTABLE SIGNAL CONDITIONER FC-33, DC SELECTABLE SIGNAL CONDITIONER Description. The FC-33 is a DIN rail or side mount, selectable input/output signal conditioner with 1500VDC isolation between input and output, and 1500VDC isolation

More information

UNIVERSAL DPM/COUNTER-TIMER. 3 in 1: TTY/USB/RS485 Display, D.P.M. & COUNTER Serial Remote Display, Loop/Signal Powered Meter, Timer/Counter/Clock

UNIVERSAL DPM/COUNTER-TIMER. 3 in 1: TTY/USB/RS485 Display, D.P.M. & COUNTER Serial Remote Display, Loop/Signal Powered Meter, Timer/Counter/Clock NEW UNIVERSAL DPM/COUNTER-TIMER 3 in 1: TTY/USB/RS485 Display, D.P.M. & COUNTER Serial Remote Display, Loop/Signal Powered Meter, Timer/Counter/Clock PATENT #9,054,721 B1 Replaces obsolete RM-2300 For

More information

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 www.keithley.com Model 2010 Low-Noise Multimeter Specifications DC CHARACTERISTICS CONDITIONS: MED (1 PLC) 1 or SLOW (5 PLC)

More information

DRG-SC Series Signal Conditioners

DRG-SC Series Signal Conditioners DRG-SC Series Signal Conditioners DRG-SC Series 245 Basic unit Models Available for Thermocouples, RTDs, DC Voltage and Current, Frequency, Strain Gage Bridge, AC Voltage and Current Field Configurable

More information

4-20mA, 0-10V and general process measuring bargraph displays

4-20mA, 0-10V and general process measuring bargraph displays Page 1 of 6 Digital panel meters Large displays Bargraphs Transmitters 4-20mA, 0-10V process input bargraph displays Display almost any physical variable... The bargraph displays on this page accept most

More information

DP2000 ORDERING GUIDE To Order MODEL NO.

DP2000 ORDERING GUIDE To Order MODEL NO. 1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition

More information

Economical Digital Indicators For Process and Electrical Measurement

Economical Digital Indicators For Process and Electrical Measurement Economical Digital Indicators For Process and Electrical Measurement DP18 Series Panel Punches Available DP18-P5, 4 to 20 ma input. DP18-EC, thermocouple input visit omega.com/thermocouple for thermocouples.

More information

This Errata Sheet contains corrections or changes made after the publication of this manual.

This Errata Sheet contains corrections or changes made after the publication of this manual. Errata Sheet This Errata Sheet contains corrections or changes made after the publication of this manual. Product Family: DL4 Date: September 12, 218 Manual Number D4-ANLG-M Revision and Date th Ed., Rev.

More information

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS

More information

Uni-Mux XQL Multi-Channel Data Acquisition Module

Uni-Mux XQL Multi-Channel Data Acquisition Module Uni-Mux XQL Multi-Channel Data Acquisition Module Uni-Mux XQL Multi-Channel Data Acquisition Module * 8 channel differential inputs. * 16 channel single ended inputs. * User programmable via P.C. software.

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

SC SERIES 1 SQUARE! SIGNAL CONDITIONERS with 4-20mA, VDC OR SERIAL OUTPUT. SCT or SCX WITH CONNECTOR SCV P.C.B. MOUNT ONLY

SC SERIES 1 SQUARE! SIGNAL CONDITIONERS with 4-20mA, VDC OR SERIAL OUTPUT. SCT or SCX WITH CONNECTOR SCV P.C.B. MOUNT ONLY NEW! SC SERIES SQUARE! SIGNAL CONDITIONERS with 0mA, VDC OR SERIAL OUTPUT AC or DC VOLTS AC or DC AMPS AC or DC WATTS 00KHZ HERTZ Acceleration, Position TIME, EVENTS DISTANCE CUSTOM SCV The Analog way

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

PID CONTROLLERS LT SERIES

PID CONTROLLERS LT SERIES PID CONTROLLERS LT SERIES The Axis family of microprocessor based controllerscombine a high degree of functionality and reliability at a very low price, in 4 different formats : 1/16 DIN, 1/8 DIN, 1/ 4

More information

7SD/7SH/7SM Temperature Controllers

7SD/7SH/7SM Temperature Controllers 7SD/7SH/7SM Temperature ADVANTAGE EZ Series 7SD, 7SH, 7SM 1/16 DIN Temperature 3Digit LED Display Thermocouple and RTD Input Autotuning NEMA 4X Field onfigurable 100 to 40 Vac Switching Power Supply Programmable

More information

DIGEM f 96 x 48 EK. Applications. Description

DIGEM f 96 x 48 EK. Applications. Description 3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel

More information

DC1010/DC1020/DC1030/DC1040

DC1010/DC1020/DC1030/DC1040 05/0 0-10-10-0-EN Page 1 of DC1010/DC1020/DC100/DC1040 DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of functionality and

More information

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model 6012-06XR Specifications & Dimensions 2 Theory of Operation 3 System Block Diagram 4 Operator Controls & Connectors 5 Test Connections

More information

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase Introduction ISOLATD SIGNAL CONDITIONING can significantly increase your system reliability here's how: Linearizes Thermocouple and RTD signals Reduces the demands on the software to linearize the signal

More information

Thermocouple Conditioner and Setpoint Controller AD596*/AD597*

Thermocouple Conditioner and Setpoint Controller AD596*/AD597* a FEATURES Low Cost Operates with Type J (AD596) or Type K (AD597) Thermocouples Built-In Ice Point Compensation Temperature Proportional Operation 10 mv/ C Temperature Setpoint Operation ON/OFF Programmable

More information

8558A 8 1/2 Digit Multimeter

8558A 8 1/2 Digit Multimeter 8558A 8 1/2 Digit Multimeter Product Specifications March 2019 Rev. A 2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks

More information

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i SNAP Isolated Analog Input Modules Features Channel-to-channel isolation Rugged packaging and convenient pluggable wiring. Accepts wire. Factory calibrated; no user adjustment necessary Out-of-range indication

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR MODEL 9050 EXTENDED SPECIFICATIONS Ü 50ppm TRANSPORTABLE CALIBRATOR 9050A EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last used up to 20 minutes maximum

More information

Digital Panel Meter Glossary

Digital Panel Meter Glossary Glossary RS-232C (Recommended Standard 232C) RS-232C is a modem interface standard for serial communications defined by the Electronic Industries Alliance (EIA). It defines the electrical specifications,

More information

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing. 1.0 Scope This document describes the specification for Toshiba 1000 Series On-Line Uninterruptible Power System (UPS). The UPS will supply a computer grade AC output sine wave which is unaffected by the

More information

1 INTRODUCTION ORDER CODE / INFORMATION

1 INTRODUCTION ORDER CODE / INFORMATION INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O

More information

Industrial Interface The Signal Conditioning People

Industrial Interface The Signal Conditioning People Loop Powered Products including: 420TW 420i RTD/TC-HEAD Isolating Terminal Blocks Loop Powered Isolators In-Head Transmitters DC/AC Powered Isolation including: ISOCON DUALCON SLIMCON TC-TC VCON STRAIN

More information

This Errata Sheet contains corrections or changes made after the publication of this manual.

This Errata Sheet contains corrections or changes made after the publication of this manual. Errata Sheet This Errata Sheet contains corrections or changes made after the publication of this manual. Product Family: DL35 Manual Number D3-ANLG-M Revision and Date 3rd Edition, February 23 Date: September

More information

7051Plus / 5051Plus. Extended Specification

7051Plus / 5051Plus. Extended Specification 7051Plus / 5051Plus Extended Specification V1.1 Time Electronics, Botany Industrial Estate,Tonbridge, Kent, TN9 1RH England Tel: 44 (0)1732 355993 Fax: 44 (0) 1732 770312. E-mail: mail@timeelectronics.co.uk

More information

CALYS 100. Field precision documenting multifunction calibrator

CALYS 100. Field precision documenting multifunction calibrator Field precision documenting multifunction calibrator is a precision documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 105U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 105U range of wireless I/O provides a low cost alternative

More information

K3P ENG.qxd 23/10/ Pagina 1

K3P ENG.qxd 23/10/ Pagina 1 K3P ENG.qxd 23/10/2003 12.30 Pagina 1 - CLEAR PROGRAM STATUS DISPLAY - DIRECT PROGRAM PARAMETER ADJUSTMENT - 8 INDEPENDENT PROGRAMS - 10 SEGMENTS FOR EACH PROGRAM - "SET - POINT TRACKING " AND "GUARANTEED

More information

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 150. Advanced documenting multifunction calibrator thermometer Advanced documenting multifunction calibrator thermometer , most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer

More information

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13.

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13. LDI 35 OPERATING INSTRUCTIONS General features 2 Technical features 3 Installation 10 Preliminary operations 12 Front panel description 13 Operating mode 15 Important: We suggest you keep the original

More information

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification 01 May 20 30-10-10--EN Page 1 of DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of

More information

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications Sefram SEFRAM Make sure to visit our Website http://wwwseframfr A new family of paperless recorders 6 to 72 channels, to cover all your applications 6 to 72 analogue channels Measurement boards : - 6 isolated

More information

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS DESCRIPTION FEATURES * Compact Size: 1/16 DIN * Dual LED displays for simultaneous indication of process temperature and set point (Lower display selectable

More information

Digital Controller Intelligent, User-friendly Digital Controller and Programmer Controlled with ease with a support software which is input via the communication jack on the front panel. Minute adjustment

More information

F3 08AD 1 8-Channel Analog Input

F3 08AD 1 8-Channel Analog Input F38AD 8-Channel Analog Input 42 F38AD Module Specifications The following table provides the specifications for the F38AD Analog Input Module from FACTS Engineering. Review these specifications to make

More information

CALYS 75. Field documenting multifunction calibrator

CALYS 75. Field documenting multifunction calibrator Field documenting multifunction calibrator is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries.

More information

BATCHMATE 1500 Batch Control Computer Technical Bulletin

BATCHMATE 1500 Batch Control Computer Technical Bulletin TS-5(C) BATCHMATE 5 Batch Control Computer Technical Bulletin DESCRIPTION The BATCHMATE features an 8 digit.55-in. alphanumeric LED display. The pulse input model will accept up to 2, pulses per second

More information

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40 Digital Panel Meters Current and Voltage Indicator/Controller Type LDM40 Multi-input instrument 4-DGT LED 0.1% RDG basic accuracy TRMS AC current and voltage measurements AC/DC current measurements: selectable

More information

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17 Proximity Section 17 Table of Contents............ 21 2 Application Guide........................ 21 3 ACT Series Transducers......... 21 4 ACTR Series Transducers........ 21 6 ACS150 Series Switches..................

More information

MICRO-CONTROLLER X (48 48 mm)

MICRO-CONTROLLER X (48 48 mm) PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature

More information

AK48 SPECIFICATIONS APPLICATIONS GENERALS FEATURES. 1/16 DIN Process controller

AK48 SPECIFICATIONS APPLICATIONS GENERALS FEATURES. 1/16 DIN Process controller /6 DIN Process controller AK48 Three control types The user can select among three different control actions: ON/OFF, PID or PID ( PI with automatic derivative action). PID and PID include two differente

More information

General Purpose Digital Controllers Specifications

General Purpose Digital Controllers Specifications General Purpose Digital Controllers Specifications DC1010 - DC1020 - DC1030 - DC1040 51-52-03-33 August 2003 Overview The DC1000 family of microprocessor based controllers combines a high degree of functionality

More information

Industrial Modbus I/O Modules

Industrial Modbus I/O Modules Industrial Modbus I/O Modules Modbus I/O Modules Introduction & Features Digital Input / Output Modules Analog Input / Output Modules Modbus I/O Modules The Best Choice For Your SCADA Applications Introduction

More information

Improve asset protection and utilization

Improve asset protection and utilization QUALITROL 509 ITM Intelligent transformer monitor Improve asset protection and utilization Immediately know your transformer health with TransLife Optimize loading and equipment life Simplify root cause

More information

ELKOR MOC1 TRANSDUCER SET - MANUAL

ELKOR MOC1 TRANSDUCER SET - MANUAL ELKOR MOC1 TRANSDUCER SET - MANUAL Elkor MOC1 Power Transducer - Product Description The MOC1 true RMS 3 phase transducer is a micro-processor based metering product that provides a cost effective and

More information

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website Make sure to visit our Website http://wwwseframfr Sefram Sefram SEFRAM A new family of thermal recorders 6 to 36 channels 6 to 36 analogue channels Measurement boards : - 6 isolated channels universal

More information

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Linearized 4-Wire RTD Input 5B35 FEATURES Single-channel signal conditioning module that Amplifies, Protects, Filters, and Isolates Analog Input. Isolates and protects a wide variety of four-wire

More information

AI-700 / 500 INTELLIGENT INDICATING/ALARMING INSTRUMENT. Operation Instruction

AI-700 / 500 INTELLIGENT INDICATING/ALARMING INSTRUMENT. Operation Instruction AI-700 / 500 INTELLIGENT INDICATING/ALARMING INSTRUMENT Operation Instruction CONTENTS Page MAIN FEATURES... 2 ORDERING CODE.3 TECHNICAL SPECIFICATION.5 FRONT PANEL AND OPERATION..7 PARAMETER AND SETTING...

More information

PL420 PROGRAMMABLE LOGIC CONTROLLER

PL420 PROGRAMMABLE LOGIC CONTROLLER PL420 PROGRAMMABLE LOGIC CONTROLLER USER MANUAL 12/01/2007 V02 P.O.Box 24 STANFIELD 3613 SOUTH AFRICA Tel: +27 (031) 7028033 Fax: +27 (031) 7028041 Email: proconel@proconel.com Web: www.proconel.com TABLE

More information

F4-08RTD 8-Channel RTD Input

F4-08RTD 8-Channel RTD Input F-8RTD 8-Channel RTD 92 F8RTD 8-Channel RTD Module Specifications The F8RTD 8 Differential Channel RTD module provides several features and benefits. It provides eight RTD input channels with 16-bit resolution.

More information

269 Troubleshooting Guide 11/4/98 1

269 Troubleshooting Guide 11/4/98 1 269 Troubleshooting Guide 11/4/98 1 Table of Contents Phase currents 3 Communications. 6 RTDs.. 9 Ground Fault Currents... 13 Output Relays. 15 Analog Output 17 Switch Inputs...18 11/4/98 2 Phase Currents

More information

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 150. Advanced documenting multifunction calibrator thermometer Advanced documenting multifunction calibrator thermometer, most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer

More information

Hawk 3 Digital Panel Meter / Controller

Hawk 3 Digital Panel Meter / Controller File # E199939 All parameters set from easy to understand front panel access One, two or four 5-amp relays optional Five user-selectable brightness levels 1/8 DIN, shallow depth case, 3.24 RS485 digital

More information

GE Fanuc IC695ALG600. Rx3i PacSystem

GE Fanuc IC695ALG600. Rx3i PacSystem GE Fanuc IC695ALG600 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic695alg600 Rx3i PacSystem UNIVERSAL ANALOG MODULE. 8 CHANNELS OF ANALOG CONFIGURABLE IC695A IC695AL IC695ALG 919-535-3180

More information

AI-501 INTELLIGENT INDICATING/ALARMING INSTRUMENT. Operation Instruction

AI-501 INTELLIGENT INDICATING/ALARMING INSTRUMENT. Operation Instruction AI-501 INTELLIGENT INDICATING/ALARMING INSTRUMENT Operation Instruction CONTENTS Page MAIN FEATURES... 2 ORDERING CODE.3 TECHNICAL SPECIFICATION.5 FRONT PANEL AND OPERATION..6 PARAMETER AND SETTING...

More information

TECHNICAL DATASHEET #TDAX INPUTS, 5 OUTPUTS VALVE CONTROLLER

TECHNICAL DATASHEET #TDAX INPUTS, 5 OUTPUTS VALVE CONTROLLER TECHNICAL DATASHEET #TDAX020510 6 INPUTS, 5 OUTPUTS VALVE CONTROLLER Up to 6 Digital, Analog or PWM Command Inputs 5 Independent Proportional or On/Off Outputs 1 +5V, 100 ma Reference Voltage CAN (SAE

More information

SPECIFICATIONS AND ORDERING INFORMATION MODELS: 100, 101, 102

SPECIFICATIONS AND ORDERING INFORMATION MODELS: 100, 101, 102 SPECIFICATIONS AND ORDERING INFORMATION MODELS: 100, 101, 102 JANUARY 31, 2002 MIL-SPEC DPM NSN: 711-1220-01-144-3867 4016 E.Tennessee St. Tucson, AZ. 85714 U.S.A. Tel: 520-748-7900 Fax: 520-790-2808 S

More information

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use Wireless New Products... New Solutions The range of telemetry modules provide remote monitoring and control by radio or twisted-pair wire, over short or long distances. Transducer signals connected at

More information

UL CONDITIONS OF ACCEPTABILITY

UL CONDITIONS OF ACCEPTABILITY Certificate Number: 1018011-1 Date: 2016-10-06 UL CONDITIONS OF ACCEPTABILITY Company Name: FUTURE DESIGN CONTROLS INC File-CCN: E197216 - QUYX2 Product Description: Process Control Equipment, Electrical

More information

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS www. transmille.com 3010A EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last

More information

F3 16AD 16-Channel Analog Input

F3 16AD 16-Channel Analog Input F3 6AD 6-Channel Analog Input 5 2 F3 6AD 6-Channel Analog Input Module Specifications The following table provides the specifications for the F3 6AD Analog Input Module from FACTS Engineering. Review these

More information

AD596/AD597 SPECIFICATIONS +60 C and V S = 10 V, Type J (AD596), Type K (AD597) Thermocouple,

AD596/AD597 SPECIFICATIONS +60 C and V S = 10 V, Type J (AD596), Type K (AD597) Thermocouple, AD597 SPECIFICATIONS (@ +60 C and V S = 10 V, Type J (AD596), Type K (AD597) Thermocouple, unless otherwise noted) Model AD596AH AD597AH AD597AR Min Typ Max Min Typ Max Min Typ Max Units ABSOLUTE MAXIMUM

More information

MODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR

MODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR MODEL 9041 EXTENDED SPECIFICATIONS 25ppm TRANSPORTABLE CALIBRATOR 9041 EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last used up to 20 minutes maximum

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 105U ISO 9001 Certified New Products... New Solutions The ELPRO 105 range of telemetry modules provide remote monitoring and control by radio or twisted-pair

More information

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com

More information

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels) Model:PFXLM4B01DDK PFXLM4B01DDC PFXLM4B01DAK PFXLM4B01DAC LT4000M Rear module Model Name Indication PFXLM4B01 D * * (1) (2) (3) (4) Notice to our valued customers who use LT4000M series (analog model)

More information

* Our controllers can be used with other brand of strain gauge sensors. Please contact RKC for more details. DO1 Control output (CH1)

* Our controllers can be used with other brand of strain gauge sensors. Please contact RKC for more details. DO1 Control output (CH1) /M R/L R/S /M R/L R/S /M R/L R/S P CPU Resin Pressure Digital Controller H90 H90 General Description The H90 strain gauge make it ideal for melt pressure control. Featuring high speed sampling and control

More information

MODEL PAX 1/8 DIN ANALOG INPUT PANEL METERS

MODEL PAX 1/8 DIN ANALOG INPUT PANEL METERS Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net Bulletin No. PAX-P Drawing No. LP0545 Released 01/15 MODEL PAX 1/8 DIN ANALOG PANEL METERS PROCESS, VOLTAGE, CURRENT, TEMPERATURE, AND STRAIN

More information

WATT TRANSDUCER. Instruction Manual

WATT TRANSDUCER. Instruction Manual WT 9200 WATT TRANSDUCER Instruction Manual IM-2 September 2003 USA: 6428 Ridglea Drive, Watauga, Texas 76148 Tel/Fax 1-817-427-2060/2067 E-mail: wes@westecinstruments.com SPECIFICATIONS Power Supply Input

More information

PFXLM4B01 D * * (1) (2) (3) (4)

PFXLM4B01 D * * (1) (2) (3) (4) Model:PFXLM4B01DDK PFXLM4B01DDC PFXLM4B01DAK PFXLM4B01DAC LT4000M Rear module Model Name Indication PFXLM4B01 D * * (1) (2) (3) (4) Notice to our valued customers who use LT4000M series (analog model)

More information

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Linearized Thermocouple Input 7B47 FEATURES Interfaces, amplifies and filters input voltages from a J, K, T, E, R, S, B or N-type thermocouple. Module provides a precision output of either +1

More information

5500A. Multi-Product Calibrator. Extended Specifications 2005

5500A. Multi-Product Calibrator. Extended Specifications 2005 5500A Multi-Product Calibrator Extended Specifications 2005 5500A Specifications The following paragraphs detail specifications for the 5500A Calibrator. The specifications are valid after allowing a warm-up

More information

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Thermocouple Input 7B37 FEATURES Interfaces, amplifies, and filters input voltages from a J, K, T, E, R, S, or B-type thermocouple. Module provides a precision output of either +1 V to +5 V or

More information

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-4

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-4 TO BE DISCONTINUED /06. FOR REPLACEMENT MODEL, CLICK HERE: NTM NEW " SHORT DEPTH PROGRAMMABLE BARGRAPHCONTROLLER FOR TIGHT SPACES NUCLEAR, MILSPEC OR INDUSTRIAL GRADE MODEL HIQ (ATB) FEATURES: Replaces:

More information