ATG SERIES Growco Servo Tank Gauges
|
|
- James Turner
- 5 years ago
- Views:
Transcription
1 GROWCO INTERNATIONAL ATG SERIES Growco Servo Tank Gauges TOTAL MEASUREMENT SOLUTIONS Bulletin ATG-S-08 Rev 03 The Growco ATG Series servo tank gauges are designed in the most advanced technology with integrated circuitry utilizing stringent military processing technology to ensure high precision and rugged construction for long term reliability. These tank gauges use industry standard communication protocols which make them to have easy access to the DCS systems or other common control devices. The ATG Series are used widely for tanks in the oil storage tanks terminals, refineries, petrochemical complex as well as industries such as foodstuff, chemical, water treatments plants, etc. FEATURES: Unique design of the patented technology, processing quality of military standards; Ability to measure the liquid level, interface (water level), temperature, density, volume & mass; High Accuracies. The measurement accuracy of liquid Typical Photograph of ATG Series level is +/-0.75 mm, the sensitivity is +/-0.1mm, the temperature accuracy is +/-0.1ºC while the density accuracy is +/ g/cm3 and water level is +/-2 mm; Option with external temperature probe; Built-in anti-lightning module; Various power supply of 220VAC or 110VAC or 24-48VDC; The local display is optional; Remote control operation functions which can set the level of various parameters through remote control; Copyright 2008 Growco International Page 1 Bulletin ATG-S-08 Rev 03
2 TYPICAL SPECIFICATIONS: Liquid level accuracy : ±0.75mm Isolating Voltage : 1,500V Temperature accuracy : ±0.1ºC Enclosure : IP65 Density accuracy :± g/cm 3 Classifications : ExdIIBT6Gb Water level : ±2mm Power Consumption : 5W Sensitivity : ±0.1mm Repeatability : ±0.1mm Measuring range : 0-32m Environment temperature: -40 to +70ºC Power supply : VAC or VDC (see the model selection table) Standard Output : RS485 Communication Options : 4-20mA, HART, BPM, MODBUS Approximate Weight : 17.5Kg Housing material : Aluminum alloy Cable entries : 4 3/4NPT PRINCIPLE OF OPERATION: The Growco ATG Series servo tank gauges are designed in the most advanced technology with integrated circuitry utilizing stringent military processing technology to ensure high precision and rugged construction for long term reliability. It comes with a displacer with options for various types to measure liquid level, water level and density. This displacer is utilizing on the buoyancy of the float. It is currently the best available choice in tank gauges technologies replacing the traditional mechanical level gauges, radar gauges or other type of gauges. Please see below diagram on our ATG and calibration adaptor for more details: Copyright 2008 Growco International Page 2 Bulletin ATG-S-08 Rev 03
3 TYPICAL ARRANGEMENT OF MULTIPLE INSTALLATIONS: The Growco ATG Series servo tank gauges which use VAC or VDC power supply can also be connected with the computers of RS485 communication equipment. In order to prevent interference, power cables and signal wires are to be connected into separate cable conduits. Below is the typical arrangement of multiple installations of the Growco ATG series servo tank gauges: Typical Multiple Installations Copyright 2008 Growco International Page 3 Bulletin ATG-S-08 Rev 03
4 20 GROWCO ATG SERIES SERVO TANK GAUGES: SOME POSSIBLE INSTALLATIONS ARRANGEMENTS Permitted cables The Growco ATG series tank gauges can be installed on the Recommended calibration adaptor vertical fixed roof tanks, vertical floating roof tanks, horizontal tanks, spherical tank and other tanks. 1. The installation on the fixed roof tanks are recommended to use stilling wells when the DN20 conduit pipes Suitable switch if necessary condition permits for better performance. Typical Fixed Roof Arrangement 2. The installation for floating roofs tanks must be installed with proper stilling wells as shown (right) to prevent problem to the displacers. Copyright 2008 Growco International Page 4 Bulletin ATG-S-08 Rev 03
5 Model codes: ATG-Series: Code Measurement Parameters: ATG-80H Measurement Function A1 Liquid Level A2 A3 Liquid Level, water Level Liquid Level, water Level, density Pressure Rating B1 Pressure of 0.5MPa B2 Pressure of 2MPa Communication Mode C1 BPM protocol C2 RS485MODBUS protocol C3 RS485 proprietary protocol C4 HART protocol C5 4-20mA + HART protocol External Devices D1 No D2 HART+PT100 D3 HART+ multi-point temperatures Supply Voltage E V/DC E2 220V/AC E3 110V/AC E V/AC Display - x Note: 1) Communication Mode Option price adders for 4-20 ma or HART or BPM or MODBUS. 2) Multi-point temperatures probe for up to 12 points are Option price adders or contact us. Copyright 2008 Growco International Page 5 Bulletin ATG-S-08 Rev 03
6 NOTICE WHEN ORDERING: Describe its application. Specify tanks heights & diameters Specify its model Specify type of tanks (i.e., fixed Specify working & max. Pressures. roof, floating roof, etc) Specify product & max. viscosity. Specify voltage Specify min. & max. temperatures. Other useful details or contact us T O T A L M E A S U R E M E N T S O L U T I O N S P R O V I D E R Member of Singapore Manufacturing Federation(Since1932) Distributed by: GROWCO INTERNATIONAL International Business Office : 271 Bukit Timah Road, #03-04 Balmoral Plaza, Singapore Tel : (65) Fax : (65) sales@growco.biz Web: Growco International reserves the rights, without notice, to alter or improve the designs or specifications of the products described herein. Origin of Singapore. Serve Globally, Act Locally Copyright 2008 Growco International Page 6 Bulletin ATG-S-08 Rev 03
TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions
Technology Solutions TEK-F LEX 4100A Guided Wave Radar Level Transmitter LEVEL www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Featuring TDR (Time Domain
More informationSmart Displacer Level (Interface) Transmitter DLT100 Series
Smart Displacer Level (Interface) Transmitter DLT100 Series Equipped with FISHER FIELDVUE DLC3010 1 Introduction DLT100 series is Smart Displacer Level (Interface) Transmitter equipped with the original
More informationLevel gauges Series LT Level indicator, switch and transmitter for liquids
Level gauges Series LT Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Excellent chemical resistance
More informationRHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits
RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English
More informationServo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.
Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell Enraf s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It
More informationENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.
ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging. Technical Specifications Data Communication Honeywell Bi-phase mark (Pos 2 = E and I) 1200 / 2400 bps > 1,500 V Full galvanic separation via isolating
More informationAmbient Conditions. Operating Conditions. Pressure
Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version
More informationSLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter
SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter Overview SLW series Turbine Flow has its simple structure, light weight, high-accuracy, perfect repeatability, sensitivity, easy maintenance and
More informationCAPACITANCE TYPE LEVEL SWITCH FOR LIQUIDS 114 MLS
LEVEL MEASUREMENT & CONTROL SOLUTIONS CAPACITANCE TYPE LEVEL SWITCH FOR LIQUIDS 114 MLS Capacitance Type Level Switch 114 MLS uses SBEM s proven capacitance technology with added feature of Microprocessor.
More informationFOSTEN AUTOMATION SÉRIE F500-RD
FOSTEN AUTOMATION SÉRIE Guided Wave Radar Level Transmitter Guided wave radar level transmitter. Low maintenance, auto calibrated references. Easy installation, directly in tanks or auxiliary vessels.
More informationLevel transmitters Series LTDR TDR guided radar level transmitter for liquids and solids
Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level measurement independent of changing process conditions (density, conductivity, temperature, pressure, ) Innovative
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationDREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance
DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement
More informationProcess Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors
Process Automation Accurate Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Flexible Sensors and Systems: www.fafnir.com Reliable FAFNIR Sensors and Systems Reliable,
More informationRadar Tank Gauging for Asphalt Inventory Measurement
White Paper November 6, 2009 Radar Tank Gauging for Asphalt Inventory Measurement This document describes the correct selection of a radar tank gauge for inventory measurement and maintainability on an
More informationFW9000NN Series SERVO BALANCE-TYPE LEVEL GAUGE OUTLINE APPLICATIONS FEATURES
FW9000NN Series SERVO BALANCE-TYPE LEVEL GAUGE OUTLINE FW9000NN Series is the successor to the well received and widely used FW-9000 series for its reliability and variety of long term application. Using
More informationDREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar
DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) and Volumetric for Total Level Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement
More informationMagnetostrictive Level Transmitter
Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Overview Söm-Tek TM The SKMT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass
More informationUltrasonic Level Transmitter.
Ultrasonic Level Transmitter www.fine-tek.com INTRODUCTION The ultrasonic level transmitter is a non-contact, low-cost and easy-to-install measuring device. It can be applied to most industrial applications
More informationTMU. Coriolis Mass Flow Meter. for liquids and gas
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationFH CMF Coriolis Mass Flow Meters
FH CMF Coriolis Mass Flow Meters 1. Introduction Coriolis Mass Flow Meters patented and developed by our company (Chinese Patent No. 03119685.3, 03149996.1) are the leading meters for precision flow measurement.
More informationLevel Measurement With REFLEX RADAR
Reflex Radar & TDR HYC-RR02 Elect. Iss. 02 Level Measurement With REFLEX RADAR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam
More informationKotron Sentinel Model 804 RF Level Transmitter
Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading-edge microprocessor-based circuitry has nonvolatile memory. The display
More informationGCS20K. Conductivity Switch FEATURES
Conductivity Switch FEATURES l 100V / 1A OPEN DRAIN OUTPUT WITH REVERSE POLARITY PROTECTION l RESOLUTION: BETTER THAN 2 ua l THE WHOLE SWITCH IS BUILT-IN THE HEAD - IT IS JUST THE PROBE AND A THIN CABLE
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More informationFW-9000 series MOST COMPACT & MOST LIGHT SUPER INTELLIGENT SERVO GAUGE OUTLINE FEATURES
MOST COMPACT & MOST LIGHT FW-9000 series SUPER INTELLIGENT SERVO GAUGE OUTLINE FW-9000 SUPER INTELLIGENT TANK GAUGE has been developed based on the technical and field application know-how obtained through
More informationProcess Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors
Process Automation Accurate Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Flexible Sensors and Systems: www.fafnir.com Reliable FAFNIR Sensors and Systems Reliable,
More informationVA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service
VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service Product Bulletin Code No. LIT-977319 Issued September 26, 2014 The VA-9070 Series Electric Rotary Actuators for Two-Position
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationRadar Level Measurement micropilot FMR 130 for stilling wells
Technical Information TI 258F/24/ae Radar Level Measurement micropilot FMR 130 for stilling wells Smart transmitter for non-contact measurement in metallic by-pass pipes and stilling wells Suitable for
More informationLevel Measurement With REFLEX RADAR
Reflex Radar & TDR HYC-RR03 Elect. Iss. 03 Level Measurement With REFLEX RADAR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam
More information6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES
6GHz Intelligent Radar Level Meter Product Manual Model:KRD520 SERIES Directory 1 Product Overview...1 2 Product Introduction...2 3 The Installation Requirements...4 4 The Electrical Connection...6 5 Instrument
More informationRUNYI GROUP. Overview. Features SLW. kind ±0.25%R. Output pulse zero drift and. Compact and. Manufacture Standard. Turbine flow meter
SILVER AUTOMATION INSTRUMENTS HTTP://WWW.SILVERINSTRUMENTS.COM RUNYI GROUP SLW Liquid Turbine Flow Meter 1 Overview SLW series Turbine Flow has its simple structure, light weight, high-accuracy, perfect
More informationJTR Guided Wave Radar Level Transmitter.
JTR Guided Wave Radar Level Transmitter www.fine-tek.com PRODUCT INTRODUCTION OPERATING PRINCIPLE The guided wave radar level transmitter is a solid and liquid level measuring instrument commonly used
More informationKotron Sentinel Model 804 RF Level Transmitter
Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading edge microprocessor-based circuitry has nonvolatile memory. The display
More informationMetal tube variable area flowmeters for gases, liquids and steam
Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationModel Sono-Trak Transit Time
Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic
More informationTarget disk flowmeters Series DP Metallic flowmeter for liquids and gases
Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions
More informationUSER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS
Rev04009 USER MANUAL DEI MODEL USFT-CS USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER The Model USFT-CS is an ultrasonic transit time flow meter designed to accurately and reliably report the flow
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More information914DNS. Pressure and Density Transmitter. Features. 1 Datasheet 914DNS Pressure and density transmitter.
Pressure and Density Transmitter Features Pressure and density transmitter. Low maintenance, quick calibration and configuration. Installation directly into pressurized vessels. HART technology provides
More informationUSER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B
Rev012008 USER MANUAL DEI MODEL USFT-B USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER The Model USFT-B is an ultrasonic transit time flow meter designed to accurately and reliably report the flow
More informationSakura Endress RCV-1000/1200. Average Temperature Measuring Element for Tank Gauging System
Technical Information TI 002 N/08/en/02.02 Average Temperature Measuring Element for Tank Gauging System RCV-1000/1200 Multi-point average temperature with tank inventory management control Introduction
More informationREFLEX RADAR INDICATOR
REFLEX RADAR INDICATOR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam Temperature THE ADVANTAGES ARE Measuring ranges up to
More informationwww. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER
www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring
More informationCAP ANALOG 410 INSTALLATION & OPERATION MANUAL
CAP ANALOG 410 INSTALLATION & OPERATION MANUAL An L&J Technologies Co. 5911 Butterfield Road Hillside, IL 60162 Phone: 708-236-6000 Fax: 708-236-6006 1 was started in 1976 to offer new and innovative electronic
More informationSLIDE VANE FLOW METER SPECIFICATIONS
SLIDE VANE FLOW METER SPECIFICATIONS V20051 17.09 1. Outline Slide vane flow meter is vane type positive displacement flow meter, creating high accuracy measurement and low pressure loss by decreasing
More information4-20mA, 0-10V and general process measuring bargraph displays
Page 1 of 6 Digital panel meters Large displays Bargraphs Transmitters 4-20mA, 0-10V process input bargraph displays Display almost any physical variable... The bargraph displays on this page accept most
More informationSubmersible pressure sensor For oils and fuels Model LF-1
Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run
More informationINTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:
Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:
More informationSeries GWL - Radar Level Transmitter for Liquids
TM Series GWL - Radar Level Transmitter for Liquids Bulletin L-GWL Specifications - Installation and Operating Instructions 4-7/16 [112.63] Ø3-19/32 [90.96] 1-9/16 [39.42] 5-19/32 [142.07] 3-17/32 [89.95]
More informationPage Type Resolution (mm) min. max. Output
Data Sheet Overview -1- Page Type Resolution (mm) min. max. Output Ind. lenght Ind. lenght 2 XM/XT-800E 5 +/- 2 400 mm 3000 mm current/voltage 6 XM/XT-825E 2.5 +/- 1 200 mm 1500 mm current/voltage 10 XM/XT-800E-PVDF
More informationS103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING
ELECTROMAGNETIC FLOW METERS The electromagnetic flow meter is used to measure the flow rate of conductive fluids and waste water. The measurement is independent of the density, viscosity, temperature and
More informationSultan Liquid- Acoustic Wave Technology
A higher level of performance Data Sheet Sultan Liquid- Acoustic Wave Technology Liquids level and position measurements to 10m (33ft) Principle of Operations The Sultan Liquid series emits a high powered
More informationORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.
A Higher Level of Performance Data Sheet ORCA Sonar System Sludge and Settling Level Interface Monitoring For more information, please visit > www.hawkmeasure.com Overview Principle of Operation The ORCA
More informationXT Technical Documentation. The magnetostrictive level sensor. Edition: Version: 1 Article no.:
Technical Documentation The magnetostrictive level sensor Edition: 11-2010 Version: 1 Article no.: 233571 Gems Sensors & Controls One Cowles Rd Plainville CT Telephone 800-378-1600 Page 2/19 Table of contents
More informationTarget disk flowmeter for liquids and gases
Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight
More informationFlow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,
DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration
More informationCONDUCTIVITY TYPE LEVEL SWITCHES
CONDUCTIVITY TYPE LEVEL SWITCHES 2460 1. CONDUCTIVITY TYPE LEVEL SWITCH - CLS It is a simple, low cost, point level controller designed for detection of conductive liquids, having low densities, high viscosities,
More informationAccuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)
More informationRod probe With coaxial tube reference probe
Capacitive level transmitters GENERAL DESCRIPTION NIVOCAP 2-wire capacitive level transmitters provide an ideal solution for level measurement of conductive or non-conductive liquids. The probe of the
More informationDREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET
t DREXELBROOK DATA SHEET DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements TDR Level Measurement Easy
More informationInstallation guide 971 SmartRadar LTi
Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl
More informationHydrostatic Level Measurement silometer FMB 672 Z, FMB 677 Z
Technical Information TI 065F/00/en Hydrostatic Level Measurement silometer FMB 672 Z, FMB 677 Z Commutec transmitters for level measurement of liquids, pastes and sludge Certified for use in explosion
More informationField IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter
Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of
More informationRosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS
Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationLevel Measurement silometer FMX 570
Technical Information TI 01F/00/en Level Measurement silometer FMX 570 Measurement of liquids and bulk solids Suitable for explosion hazardous areas For use with capacitance and hydrostatic probes The
More informationInstallation guide 873 SmartRadar Control Unit & Antenna Unit
Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl
More informationHigh-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet
High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N All rights reserved. The contents provided herein must
More informationInstallation guide 854 XTG Level Gauge
Installation guide 854 XTG Level Gauge July 2008 Part no. 4416.276 Rev. 5 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com
More informationAdvanced instrumentation solutions crafted with highest precision
www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Working Principle The Transit Time Flowmeter utilises two transducers that function as both ultrasonic transmitters
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement
ULTRASONlC FlOWMETER SAMPLE BOOK TYPE:LRF-3300S Concentrating on Flow Measurement Introduction LRF-3300S is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp
More informationSitron Capacitive Level Sensors
Sitron Capacitive evel Sensors Models: SC404 SC120CN200 SC400V400 SC700 Introduction Capacitive evel Sensors, also referred to as Radio Frequency (RF) level sensors, are used for measuring process level
More informationPSI Temperature Scanners
Networkable Voltage & Temperature Instruments Withstand 30 g and 160 db Smart Connector with Auto Sensor Discovery NetScanner Compatible DESCRIPTION The PSI 9146 and 9046-S are networkable instruments
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationUltrasonic Sludge Density Monitoring System
Ultrasonic Sludge Density Monitoring System ` The ENV-200 is an ultrasonic instrument that measures the density of suspended solid in liquid. It comprises of sensors, a controller, and a junction box.
More information2-wire level transmitter
Badger Meter Europa GmbH 2-wire level transmitter Model L2xx INSTALLATION AND OPERATION MANUAL July 2002 Version UF-L2xx-07/02-e Contents Contents Page 1. Installation 1 1.1 Mounting the instrument 1 1.2
More informationADDMAS CORIOLIS MASS FLOW METER
ADDMAS CORIOLIS MASS FLOW METER 1. General ADDMAS Series Coriolis Mass Flow meter (here after we call CMF ) is designed according to the coriolis principle. It can be widely used for the process detecting
More informationCoriolis Mass Flow Meter Model TM
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :
More informationMicro Motion Fork Viscosity Meters
Product Data Sheet PS-001486, Rev B June 2014 Micro Motion Fork Viscosity Meters High performance multi-variable viscosity meter Rugged, accurate multi-variable measurement Continuous, multi-variable measurement
More informationVersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009
VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement
More informationTHE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)
THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC) Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic, single-point level controller
More informationFGM 160 Ultrasonic Flaregas meter. Flare Gas Measurement
Fluenta Overview FGM 160 Ultrasonic Flaregas meter Flare Gas Measurement Why Measure Flare Gas? Flare systems at offshore production platforms, refineries and chemical plants are primarily installed for
More informationABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible
ABB MEASUREMENT & ANALYTICS LLT100, LM80 and LM200 Lasers for level now everything is possible 2 L LT 1 0 0, L M 8 0 A N D L M 2 0 0 L A S E R S F O R L E V E L N O W E V E R Y T H I N G I S P O S S I
More informationSuperMini SonicLaser
INSTRUCTION MANUAL SuperMini SonicLaser Ultrasonic Level Transmitter HiTECH Technologies, Inc. 301 Oxford Valley Road - Building 505A - Yardley, PA 19067-7706 Tel: 215. 321. 6012; Fax: 215. 321. 6067 Tech
More informationModel S50-D Density Sensor Specifications
Issue/Rev. 0.1 (4/99) S-Mass Meter S50-D Density Specifications ulletin SS0M020 The S-Mass Density derives its name from the S-shaped tubes of the flow sensor. This patented geometry produces a high signal-to-noise
More informationLevel Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision K FEATURES 4 to 20
More informationParts Per Million Dissolved Oxygen Systems
Parts Per Million Dissolved Oxygen Systems Model 900 Portable s Model 9100 Model 9200 Model 9300 The Royce line of PPM level dissolved oxygen (DO) analyzers is the largest, most varied line in the world.
More informationGuided Wave Radar vs. Non-Contact Radar for Level Measurement
WHITE PAPER Guided Wave Radar vs. Non-Contact Radar for Level Measurement INTRODUCTION Two of the most commonly used types of radar transmitters on the market today is Guided Wave Radar and Non-Contact
More informationAccuSolar SOLAR POWERED SYSTEM
AccuSolar SOLAR POWERED SYSTEM FLO-CORP s AccuSolar Solar Powered Level Monitoring System monitors process conditions through wireless WiFi that communicate up to 1,500 feet to a base station PC. The Solar
More informationOPTISONIC Ultrasonic flowmeter for liquids in all industrial applications
OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature
More informationMagnetic level switches ERH-xx-20
edit. II 2015/ page 5 Magnetic level switches ERH-xx-20 Description 3 Level signalling of the medium having minimum density 0,70 g/cm. The basic version, mounted from the top, is available with 92x92mm
More informationSubmersible pressure sensor For water and wastewater Model LW-1
Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and
More information3 & 4 Wire Self Compensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg.
& 4 Wire Self ompensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg. FETURES S.S. 1L Face Material c/w Tri-lamp Mtg. Base Simple push-button calibration (ccurate) Output 4-20 m / 20-4
More informationKMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display
Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications