Residential Water Meters

Size: px
Start display at page:

Download "Residential Water Meters"

Transcription

1 EnergyMetering Residential Water Meters Multi-jet wet dial meters Positive displacement meters All that counts.

2 Multi-jet wet dial meters Options of the D-register at a glance Register and smart metering options 7- or 8-digit rollers register The ZENNER D-register is available as 7- or 8-digit roller regis- INTERNET ter. The version with 7-digit rollers and a magnetic pointer can be scanned by reed pulser. The 8-digit rollers version is equipped with a modulator disc. D-register with magnet pointer Modulator disc With the modulator disc, the D-register is prepared for electronic 1 1 and has the optimum features for reliand non-reactive scanning able and error-free data transfer via radio, or pulse. Other features are protection against tampering and water flow direction detection. -ready Radio Ra IN Pulser ring Radio 1 Radio-ready 1 1 module, the model with mo With the addition of an add-on radio Radio 1 INTERNET 1 dulator disc can be read via radio (w as per OMS). A radio module transmits the register data to a radio modem and these are relayed to a PC or hand-held computer via Bluetooth. Radio add-on the 8-digit rollers register Using a special module, INTERNET model with modulator disc can be integrated into an sys1 1 in which all registers on a property are connected tem, together and can be read centrally. Pulse output-ready 1 1 and the 8-digit Both the 7-digit rollers model with magnet pointer INTERNET rollers model with modulator disc provide the option of reading the register data remotely. INTERNET IN Pulse counter IZM multipulse Ra 1 1

3 Positive displacement meters Remote readout with the D-register INTERNET 1 1 D-register with modulator disc Radio INTERNET INTERNET Copper Radio Can Radio Radio EDC pulse module EDC module EDC radio module converter MinoConnectRadio Handheld Computer with GMM 21

4 Multi-jet wet dial meters MTKD-N and MTKD-M Multi-jet dry dial meter for cold water In use by the million worldwide the MTK will convince you thanks to their high technical standard and high-quality workmanship. The MTKD is equipped with the new ZENNER D-register. MTKD is available in two versions: MTKD-N with 7-digit rollers and magnet pointer for pulse output. MTKD-M with 8-digit rollers register and modulator disc for non-reactive scanning for radio (wireless ), or pulse. Precise measurement results are achieved, even where the water quality varies or in the most difficult installation situations. MTKD-N INTERNET 1 Performance characteristics in overview High-quality UV-resistant plastic inspection window Dry dial register with shielded magnetic coupling Rotatable and individually inscribable lidring Operating temperature up to C, optional up to 50 C Operating pressure PN 16 Radio 1 Water meter for horizontal and vertical installation Register available as copper can version (IP 68) Version MTKD-N with pulse output (reed) for remote readout Standard pulse value 10 l/pulse, optional 1 l/pulse available Version MTKD-M with modulator disc for non-reactive scanning Approved in accordance with MID 1 1 MTKD-M 1 1 Radio

5 Positive displacement meters MTKD-L-N and MTKD-L-M Multi-jet dry dial meter with an innovative plastic housing The new series of our multi-jet dry dial meter are an improvement of the classical MTK. Its main features are a low starting flow and reliable performance even with aggressive water qualities or dezincification effects. Constant development guarantees accurate measuring results and the best long-term stability. The MTKD-L is equipped with the new ZENNER D-register and ready for all future AMR-applications. MTKD-L is available in two versions: MTKD-L-N with 7-digit rollers and magnet pointer for pulse output. MTKD-L-M with 8-digit rollers register and modulator disc for non-reactive scanning for radio, or pulse. Performance characteristics in overview Almost 50% lighter than a meter with a brass housing Housing made from high-quality UV-resistant polymer composite Dry dial register with shielded magnetic coupling High-quality UV-resistant plastic inspection window Operating temperature up to C Operating pressure PN 16 Water meter for horizontal installation Register available as copper can version (IP 68) Version MTKD-L-N with pulse output (reed) for remote readout Standard pulse value 10 l/pulse, optional 1 l/pulse available Version MTKD-L-M with modulator disc for non-reactive scanning Approved in accordance with MID MTKD-L-N 1 1 Radio 1 1 MTKD-L-M INTERNET 1 1 Radio

6 Multi-jet wet dial meters Technical data MTKD-N, MTKDI-N, MTKD-M Permanent flow Q 3 m³/h 2,5 4 6, Comparable to nominal flow (EWG) Qn m³/h 1,5 2,5 3,5 6 6 Attainable measuring range Q 3 /Q 1 R 100H/31,5V 160H/40V 125H/50V 160H/50V 160H/50V Standard measuring range (*) Q 3 /Q 1 R R25 0H R25 0H R40 0H R40 0H R40 0H Comparable to metrological class (EWG) class A / B-H A / B-H A / B-H A / B-H A / B-H Overload flow (**) Q 4 m³/h 3,13 5 7,88 12,5 12,5 Minimum flow (**) Q 1 l/h 100 / 31H 160 / 50H 158 / 79H 250 / 125H 250 / 125H Start-up flow rate - l/h <10 <10 <18 <18 <18 Display range min l 0,02 0,02 0,02 0,02 0,02 max m³ Maximum temperature - C Operating pressure, max. PN bar Pulse value l/pulse 1/10 1/10 1/10 1/10 1/10 Dimensions: Nominal diameter DN mm inch ½" ¾" 1" 1" 1 ¼" Overall length without connectors (*) L2 mm 165/ Overall length with connectors approx. L1 mm 245/ Thread meter G x B D1 inch ¾" 1" 1 ¼" 1 ¼" 1 ½" Thread connector R x D2 inch ½" ¾" 1" 1" 1 ¼" Width approx. B mm Height (plastic glass) approx. H1 k* mm H2 mm H3 mm Weight approx. - kg 1,2 1,3 2,1 2,1 2,1 (*) Other measuring ranges (R) and overall lengths on request. (**) The data refer to the standard measuring range k* plastic glass Dimensions MTKD-N/ -M, MTKD-L-N/ -M Dimensions MTKDI-N, MTKDI-L-N with pulser 24

7 Positive displacement meters Technical data MTKD-N, MTKDI-N, MTKD-M MTKD-L-N, MTKDI-L-N, MTKD-L-M Permanent flow Q 3 m³/h ,5 4 Comparable to nominal flow (EWG) Qn m³/h ,5 2,5 Attainable measuring range Q 3 /Q 1 R 160H 25any 125H/40V 125H/40V 100H/31,5V 160H/40V Standard measuring range (*) Q 3 /Q 1 R R25 0H 80H/40V 80H/40V R25 0H R25/0H Comparable to metrological class (EWG) class A / B-H B-H B-H A / B-H A/B-H Overload flow (**) Q 4 m³/h 20 31,3 31,3 3,13 5 Minimum flow (**) Q 1 l/h 640 / 200H 313H 313H 100 / 31H 160/50H Start-up flow rate - l/h <40 <25 <25 <10 <10 Display range min l 0,1 0,1 0,1 0,02 0,02 max m³ Maximum temperature - C Operating pressure, max. PN bar Pulse value l/pulse 1/10 1/10 1/10 1/10 1/10 Dimensions: Nominal diameter DN mm inch 1 ½" 2" --- ½" ¾" Overall length without connectors (*) L2 mm / Overall length with connectors approx. L1 mm / Thread meter G x B D1 inch 2" 2 ½" flange ¾" 1" Thread connector R x D2 inch 1 ½" 2" --- ½" ¾" Width approx. B mm Height (plastic glass) approx. H1 k* mm H2 mm H3 mm Weight approx. - kg 4,0 4 9,5 0,6 0,6 (*) Other measuring ranges (R) and overall lengths on request. (**) The data refer to the standard measuring range k* plastic glass Typical accuracy curve Q1 = the minimum flow Q2 = the transitional flowrate Q3 = the permanent flow Q4 = the overload flow Typical pressure loss curve 25

8 Multi-jet wet dial meters MTKD-N-ST and MTKD-M-ST Multi-jet dry dial meter in a riserpipe design The proven MTK dry dial measuring insert is available in a riserpipe housing for water meter installation in vertical pipelines with an upwards flow direction. This water meter fits perfectly into all installation locations designated for riserpipe meters and makes calibration replacement uncomplicated. The MTKD-ST is equipped with the new ZENNER D-register. MTKD-ST is available in two versions: MTKD-N-ST with 7-digit rollers and magnet pointer for pulse output. MTKD-M-ST with 8-digit rollers register and modulator disc for non-reactive scanning for radio, or pulse. In comparison with a vertically installed standard water meter, the register keeps on functioning, even in a horizontal position. Thanks to the resulting decrease in bearing load, a significant improvement in the long-term measuring result stability can be achieved. MTKD-N-ST MTKD-M-ST Radio INTERNET Performance characteristics in overview Dry dial register with shielded magnetic coupling Rotatable and individually inscribable lidring High-quality UV-resistant plastic inspection window Operating temperature up to C, optional up to 50 C Operating pressure PN 16 Water meter for vertical installation (riserpipe) Register available as copper can version (IP 68) Version MTKD-N-ST with pulse output (reed) for remote readout Standard pulse value 10 l/pulse, optional 1 l/pulse available Version MTKD-M-ST with modulator disc for non-reactive scanning Approved in accordance with MID 1 1 Radio

9 Positive displacement meters MTKD-N-FA and MTKD-M-FA Multi-jet dry dial meter in a downpipe design The proven MTK water meters dry dial measuring insert is available in a downpipe housing for vertical installation positions with a downward flow direction. This water meter fits perfectly into all installation locations designated for downpipe meters and makes calibration replacement uncomplicated. The MTKD-FA is equipped with the new ZENNER D-register. MTKD-FA is available in two versions: MTKD-N-FA with 7-digit rollers and magnet pointer for pulse output. MTKD-M-FA with 8-digit rollers register and modulator disc for non-reactive scanning for radio, or pulse. In comparison with a vertically installed standard water meter, the register keeps on functioning, even in a horizontal position. Thanks to the resulting decrease in bearing load, a significant improvement in the long-term measuring result stability can be achieved. MTKD-N-FA Performance characteristics in overview Dry dial register with shielded magnetic coupling Rotatable and individually inscribable lidring High-quality UV-resistant plastic inspection window Operating temperature up to C, optional up to 50 C Operating pressure PN 16 Water meter for vertical installation (downpipe) Register available as copper can version (IP 68) Version MTKD-N-FA with pulse output (reed) for remote readout Standard pulse value 10 l/pulse, optional 1 l/pulse available Version MTKD-M-FA with modulator disc for non-reactive scanning Approved in accordance with MID Radio MTKD-M-FA INTERNET 1 1 Radio

10 Multi-jet wet dial meters Technical data MTKD-N-ST, MTKDI-N-ST, MTKD-M-ST Permanent flow Q 3 m³/h 2,5 4 6, Comparable to nominal flow (EWG) Qn m³/h 1,5 2,5 3, Attainable measuring range Q 3 /Q 1 R 100H 160H 100H 125H 125H Standard measuring range (*) Q 3 /Q 1 R 0H 0H 0H 0H 0H Comparable to metrological class (EWG) class B-H B-H B-H B-H B-H Overload flow (**) Q 4 m³/h 3,13 5 7,88 12,5 20 Minimum flow (**) Q 1 l/h 31H 50H 79H 125H 200H Start-up flow rate - l/h <10 <10 <18 <18 <40 Display range min l 0,02 0,02 0,02 0,02 0,02 max m³ Maximum temperature - C Operating pressure, max. PN bar Pulse value l/pulse 1/10 1/10 1/10 1/10 1/10 Dimensions: Nominal diameter DN mm inch ¾" ¾" 1" 1" 1 ½" Overall length without connectors (*) L2 mm Overall length with connectors approx. L1 mm Thread meter G x B D1 inch 1" 1" 1 ¼" 1 ¼" 2" Thread connector R x D2 inch ¾" ¾" 1" 1" 1 ½" Width approx. B mm Height (plastic glass) approx. H1 k* mm H3 mm Weight approx. - kg 1,7 1,7 2,1 2,1 4,0 (*) Other measuring ranges (R) and overall lengths on request. (**) The data refer to the standard measuring range k* plastic glass Dimensions MTKD-N-ST/ -M-ST Dimensions MTKDI-N-ST with pulser Dimensions MTKD-N-FA/ -M-FA 28

11 Positive displacement meters Technical data MTKD-N-FA, MTKDI-N-FA, MTKD-M-FA Permanent flow Q 3 m³/h 2,5 4 Comparable to nominal flow (EWG) Qn m³/h 1,5 2,5 Attainable measuring range Q 3 /Q 1 R 100H 160H Standard measuring range (*) Q 3 /Q 1 R 0H 0H Comparable to metrological class (EWG) class B-H B-H Overload flow (**) Q 4 m³/h 3,13 5 Minimum flow (**) Q 1 l/h 31H 50H Start-up flow rate - l/h <10 <10 Display range min l 0,02 0,02 max m³ 9 9 Maximum temperature - C Operating pressure, max. PN bar Pulse value l/pulse 1/10 1/10 Dimensions: Nominal diameter DN mm inch ¾" ¾" Overall length without connectors (*) L2 mm Overall length with connectors approx. L1 mm Thread meter G x B D1 inch 1" 1" Thread connector R x D2 inch ¾" ¾" Width approx. B mm Height (plastic glass) approx. H1 k* mm H3 mm Weight approx. - kg 1,7 1,7 (*) Other measuring ranges (R) and overall lengths on request. (**) The data refer to the standard measuring range k* plastic glass Dimensions MTKDI-N-FA with pulser Typical accuracy curve Q1 = the minimum flow Q2 = the transitional flowrate Q3 = the permanent flow Q4 = the overload flow Typical pressure loss curve 29

12 Multi-jet wet dial meters MTKD-S Multi-jet dry dial meter for cold water Equipped with the new ZENNER D-register, the MTKD-S is a compact dry dial multi-jet meter for cold potable water with a lightweight brass body. Our developers succeeded in reducing substantially the weight of the brass body - with positive effects on the measuring quality. The innovation is called MTKD-S. S stands for small body. It s almost 25% lighter than a WVG brass housing. Technical data MTKD-S, MTKD-S-N, MTKD-S-M MTKD-S-N MTKD-S-M Dimensions MTKD-S 1 Radio INTERNET Radio Permanent flow Q 3 m³/h 1,6 2,5 4 Comparable to nominal flow (EWG) Qn m³/h 1,0 1,5 2,5 Attainable measuring range Q 3 /Q 1 R 100H/25V 160H/40V 160H/40V Standard measuring range (*) Q 3 /Q 1 R 0H 0H 0H Comparable to metrological class (EWG) class B-H B-H B-H Overload flow (**) Q 4 m³/h 2,0 3,13 5,0 Minimum flow (**) Q 1 l/h 20H 31H 50H Start-up flow rate - l/h <8 <8 <10 Display range min l 0,02 0,02 0,02 max m³ Maximum temperature - C Operating pressure, max. PN bar Pulse value l/pulse 1/10 1/10 1/10 Dimensions: Nominal diameter DN mm inch ½" ½" ¾" Overall length without connectors (*) L2 mm 165/ / Overall length with connectors approx. L1 mm 245/ / Thread meter G x B D1 inch ¾" ¾" 1" Thread connector R x D2 inch ½" ½" ¾" Width approx. B mm Height (plastic glass) approx. H1 k* mm Height (mineral glass) approx. H1 m* mm H3 mm Weight approx. - kg 0,85/0,95 0,85/0,95 1,0 (*) Other measuring ranges (R) and overall lengths on request. (**) The data refer to the standard measuring range k* plastic glass / m* mineral glass 30

13 Positive displacement meters MTWD-N and MTWD-M Multi-jet dry dial meter for hot water up to C The MTWD is a multi-jet dry dial meter for hot water up to C. The MTWD water meter is ideally suited for measuring tasks at temperatures up to C. By using special materials in the hot water version of the multi-jet dry dial meter, we can combine outstanding measurement readings with a high maximum temperature. The MTWD is equipped with the new ZENNER D-register. MTWD is available in two versions: MTWD-N with 7-digit rollers and magnet pointer for pulse output. MTWD-M with 8-digit rollers register and modulator disc for non-reactive scanning for radio, or pulse. MTWD is available in unpainted housing as standard. Performance characteristics in overview Dry dial register with shielded magnetic coupling Rotatable and individually inscribable lidring High-quality UV-resistant plastic inspection window Operating temperature up to C Operating pressure PN 16 Water meter for horizontal and vertical installation Register available as copper can version (IP 68) Version MTWD-N with pulse output (reed) for remote readout Standard pulse value 10 l/pulse, optional 1 l/pulse available Version MTWD-M with modulator disc for non-reactive scanning Approved in accordance with MID MTWD-N 1 1 Radio 1 1 MTWD-M INTERNET 1 1 Radio

14 Multi-jet wet dial meters MTWD-N-ST and MTWD-M-ST Multi-jet dry dial meter for hot water in a riserpipe design The MTW multi-jet measuring insert is available in a riserpipe housing for vertical installation positions with an upwards flow direction. This water meter fits perfectly into all installation locations designated for riserpipe meters and makes calibration replacement uncomplicated. The MTWD-ST is equipped with the new ZENNER D-register. MTWD-ST is available in two versions: MTWD-N-ST with 7-digit rollers and magnet pointer for pulse output. MTWD-M-ST with 8-digit rollers register and modulator disc for non-reactive scanning for radio, or pulse. MTKD-ST is available in unpainted housing as standard. In comparison with a vertically installed standard water meter, the register keeps on functioning, even in a horizontal position. Thanks to the resulting decrease in bearing load, a significant improvement in the long-term meas- MTWD-N-ST uring result stability can be achieved. MTWD-M-ST Radio Performance characteristics in overview Dry dial register with shielded magnetic coupling Rotatable and individually inscribable lidring High-quality UV-resistant plastic inspection window 1 INTERNET Operating temperature up to C Operating pressure PN 16 Water meter for vertical installation (riserpipe) Register available as copper can version (IP 68) Version MTWD-N-ST with pulse output (reed) for remote readout Standard pulse value 10 l/pulse, optional 1 l/pulse available Version MTWD-M-ST with modulator disc for non-reactive scanning Approved in accordance with MID 1 1 Radio

15 Positive displacement meters MTWD-N-FA and MTWD-M-FA Multi-jet dry dial meter for hot water in a downpipe design The MTW multi-jet measuring insert is available in a downpipe housing for vertical installation positions with an downwards flow direction. This water meter fits perfectly into all installation locations designated for downpipe meters and makes calibration replacement uncomplicated. The MTWD-FA is equipped with the new ZENNER D-register. MTWD-FA is available in two versions: MTWD-N-FA with 7-digit rollers and magnet pointer for pulse output. MTWD-M-FA with 8-digit rollers register and modulator disc for non-reactive scanning for radio, or pulse. MTKD-FA is available in unpainted housing as standard. In comparison with a vertically installed standard water meter, the register keeps on functioning, even in a horizontal position. Thanks to the resulting decrease in bearing load, a significant improvement in the long-term measuring result stability can be achieved. MTWD-N-FA Performance characteristics in overview Dry dial register with shielded magnetic coupling Rotatable and individually inscribable lidring High-quality UV-resistant plastic inspection window Operating temperature up to C Operating pressure PN 16 Water meter for vertical installation (downpipe) Register available as copper can version (IP 68) Version MTWD-N-FA with pulse output (reed) for remote readout Standard pulse value 10 l/pulse, optional 1 l/pulse available Version MTWD-M-FA with modulator disc for non-reactive scanning Approved in accordance with MID Radio MTWD-M-FA INTERNET 1 1 Radio

16 Multi-jet wet dial meters Technical data MTWD-N, MTWDI-N, MTWD-M Permanent flow Q 3 m³/h 2,5 4 6, Comparable to nominal flow (EWG) Qn m³/h 1,5 2,5 3, Attainable measuring range Q 3 /Q 1 R 80H/25V 80H/40V 80H/25V 80H/40V 80H/40V 80H/40V Standard measuring range (*) Q 3 /Q 1 R 80H 80H 80H 80H 80H 80H Comparable to metrological class (EWG) class B-H B-H B-H B-H B-H B-H Overload flow (**) Q 4 m³/h 3,13 5 7,88 12,5 12,5 20 Minimum flow (**) Q 1 l/h 31H/100V 50H/100V 79H/252V 125H/250V 125H/250V 200H/400V Start-up flow rate - l/h <10 <10 <18 <18 <18 <40 Display range min l 0,02 0,02 0,02 0,02 0,02 0,02 max m³ Maximum temperature - C Operating pressure, max. PN bar Pulse value l/pulse 1/10 1/10 1/10 1/10 1/10 1/10 Dimensions: Nominal diameter DN mm inch ½" ¾" 1" 1" 1¼" 1½" Overall length without connectors (*) L2 mm 165/ Overall length with connectors approx. L1 mm 245/ Thread meter G x B D1 inch ¾" 1" 1 ¼" 1 ¼" 1 ½" 2" Thread connector R x D2 inch ½" ¾" 1" 1" 1 ¼" 1½" Width approx. B mm Height approx. H1 mm H2 mm ~35 ~35 ~35 ~40 ~40 ~50 H3 mm Weight approx. - kg 1,3 1,6 2,1 2,1 2,2 3,6 (*) Other measuring ranges (R) and overall lengths on request. (**) The data refer to the standard measuring range Dimensions MTWD-N/ -M Dimensions MTWDI-N with pulser Dimensions MTWD-N-ST/ MTWD-M-ST 34

17 Positive displacement meters Technical data MTWD-N-ST/FA, MTWDI-N-ST/FA, MTWD-M-ST/FA Permanent flow Q 3 m³/h Comparable to nominal flow (EWG) Qn m³/h 2, Attainable measuring range Q 3 /Q 1 R 160H 125H 125H Standard measuring range (*) Q 3 /Q 1 R 0H 0H 0H Comparable to metrological class (EWG) class B-H B-H B-H Overload flow (**) Q 4 m³/h 5 12,5 20 Minimum flow (**) Q 1 l/h 50H 125H 200H Start-up flow rate - l/h <10 <18 <40 Display range min l 0,02 0,02 0,02 max m³ Maximum temperature - C Operating pressure, max. PN bar Pulse value l/pulse 1/10 1/10 1/10 Dimensions: Nominal diameter DN mm inch ¾ 1" 1 ½" Overall length without connectors (*) L2 mm 105 ST/FA 150 ST 150 ST Overall length with connectors approx. L1 mm Thread meter G x B D1 inch 1" 1 ¼" 2" Thread connector R x D2 inch ¾" 1" 1 ½" Width approx. B mm Height approx. H1 mm H3 mm Weight approx. - kg 1,7 2,1 4,0 (*) Other measuring ranges (R) and overall lengths on request. (**) The data refer to the standard measuring range Dimensions MTWDI-N-ST with pulser Dimensions MTWD-N-FA/ MTWD-M-FA Dimensions MTWDI-N-FA with pulser 35

18 Multi-jet wet dial meters Options for multi-jet dry dial meters Copper can (protection class IP 68) Optionally all the dry dial multi-jet and positive-displacement meter models are also available with protection class IP68. In this variant, the register is flood-proof (IP68) due to hermetically sealed roller register made of glass/ copper. Even in case of flooding, the register operates reliably. Anti-magnet ring Water meters and other measuring devices may slow down in the vicinity of a magnet or even stop. In order to prevent a reduction in the accuracy of measurement or manipulation by magnetic influences, all dry dial and positive displacement meter models are equipped as standard with an anti-magnetic ring. Anti-fog tools (wiper option, nano coating) Due to lack of insulation in the house connection or due to extreme climatic conditions, e.g. with high humidity, condensation may form on the lens of the water meter. ZENNER offers to provide the lenses with a nano coating, so that condensation can not occur. For optimal viewing in all conditions, the registers of the dry dial and positive displacement meters can also be optionally equipped with a wiper. The wiper allows the reading of the digit rollers even with condensation in the register. 36

19 Positive displacement meters Options in a glance for cold and hot water Copper can Anti-magnet Nano coating Wiper Pulser Radio (w) MTKD-N MTKD-N-ST, MTKD-N-FA MTKD-M MTKD-M-ST, MTKD-M-FA MTKD-L-N MTKD-L-M MTKD-S-N MTKD-S-M MTWD-N MTWD-N-ST, MTWD-N-FA Positive displacement meters for cold water MTWD-M MTWD-M-ST, MTWD-M-FA RTKD-S-N RTKD-S-M 37

20 Multi-jet wet dial meters RTKD-N and RTKD-M Positive displacement dry dial meter for cold water Equipped with the newly developed dry dial D-register by ZENNER, the new RTKD positive displacement meter is a meter for all who place the highest demands on reliability and measuring accuracy. The RTKD records the flow rate using the volumetric measuring principle and, in this way, guarantees extremely precise consumption recording and accounting. The RTKD positive displacement meter also has a high measuring range and a very good measurement stability. The reliable workmanship and durability of the RTKD increase the potential period of use and hence the cost-effectiveness of the meter. RTKD-N Due to a variety of technical options, the RTKD has been optimally equipped for the future. The newly developed modulator disc in combination with the new EDC communication module enables nonreactive electronic scanning 1 1 with a variable resolution and is the basis for automated meter reading via radio, or impulse module. Radio RTKD-M 1 1 INTERNET 1 1 Performance characteristics in overview Dry dial register with shielded magnetic coupling Register can be turned through 355 Water meter for horizontal and vertical installation Register available as copper can version (IP 68) Version RTKD-N with pulse output (reed) for remote readout Version RTKD-M with modulator disc for non-reactive scanning Approved in accordance with MID Radio 1 1 RTKD-L with composite housing. Available from fall

21 Positive displacement meters Technical data RTKD-N, RTKD-M Permanent flow Q 3 m³/h 1,6 1,6 2,5 2,5 2,5 4 Comparable to nominal flow (EWG) Qn m³/h 1 1 1,5 1,5 1,5 2,5 Attainable measuring range Q 3 /Q 1 R Standard measuring range (*) Q 3 /Q 1 R Comparable to metrological class (EWG) class C-H/V C-H/V C-H/V C-H/V C-H/V C-H/V Overload flow (**) Q 4 m³/h 2 2 3,13 3,13 3,13 5 Minimum flow (**) Q 1 l/h Start-up flow rate - l/h Maximum temperature - C Operating pressure, max. PN bar Pressure loss at Q 4 bar 0,3 0,3 0,75 0,75 0,75 0,6 Dimensions: Nominal diameter DN mm inch ½" ½" ½" ½" 1" 1" Overall length without connectors (*) L2 mm 110/ / / / / /190 Overall length with connectors approx. L1 mm 190/ / / / / /286 Thread meter G x B D1 inch ¾" ¾" ¾" ¾" ¾" ¾" Width B mm 89,5 89,5 89,5 89, Height H1 mm 114,5 114,5 114,5 114, Weight approx. - kg 0,86 0,98 0,86 0,98 1,10/1,15 1,10/1,15 (*) Other measuring ranges (R) on request. (**) The data refer to the standard measuring range pressure loss [Mpa] flow [m³/h] Dimensions RTKD-N/ -M 39

Bulk water meter. All that c ou n t s. EnergyMetering

Bulk water meter. All that c ou n t s. EnergyMetering EnergyMetering Bulk water meter WPD (type Woltman parallel, 1) WPHD (type Woltman parallel, ) WSD (type Woltman perpendicular ) All that c ou n t s. WPD / WPHD Woltman meter with parallel turbine shaft

More information

MID MP-01, MP WATER MEASUREMENT

MID MP-01, MP WATER MEASUREMENT FROM METERING TO DATA MANAGEMENT WATER MP-0, MP30-0 PROPELLER WATER METER WITH VERTICAL ROTOR AXIS DN40 DN0 MID APPROVED MP-0 is a dry Woltmant propeller water meter with the vertical rotor axis which

More information

EDC communication module

EDC communication module EnergyMetering EDC communication module Water meter clip-on module for secure remote reading for integration of water meters in Smart Metering AMR/AMI Systems All that counts. EnergyMetering EDC communication

More information

NUBIS. R t o WATER MEASUREMENT

NUBIS. R t o WATER MEASUREMENT FROM METERING TO DATA MANAGEMENT WATER NUBIS PROPELLER WATER METER WITH HORIZONTAL IMPELLER AXLE MID APPROVED Nubis is propeller, dry water meter Woltman s type, with horizontal impeller axle, parallel

More information

WESAN WP E ELECTRONIC METER WOLTMAN

WESAN WP E ELECTRONIC METER WOLTMAN APPLICATION Fully electronic bulk water meter for measuring the flow (cold water up to 30 C) in supply lines with high flow at low pressure loss. Highly accurate recording of all billing data. FEATURES

More information

SN+ MID MASTER + APPLICATION WATER METERS

SN+ MID MASTER + APPLICATION WATER METERS SMART THINKING WATER METERS MASTER + SINGLE-JET DRY WATER METERS DN25, DN32, DN40 MID R 100 Master+ is a single-jet dry meter intended to measurement of quantity of consumption. Thank to modern construction

More information

Nubis propeller water meter with horizontal impeller axle

Nubis propeller water meter with horizontal impeller axle Nubis propeller water meter with horizontal impeller axle Nubis is propeller, dry water meter Woltman s type, with horizontal impeller axle, parallel to pipe axles. Nubis water meters are characterized

More information

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body Size : Connection End : Min Temperature : Max Temperature : DN 50 to 200 Flanged R.F. PN10/16 0 C ( for cold water type ) + 90 C (for hot water type ) Max Pressure : 16 Bars Specifications : Horizontal

More information

Energy Technology. AMR Systems

Energy Technology. AMR Systems Energy Technology AMR Systems Bus systems Wireless M-Bus radio system LPWAN radio system (LoRaWAN, SIGFOX) Stationary GSM system Electronic components Software solutions 1 2 ZENNER AMR Systems Flexible,

More information

EC type-examination certificate UK/0126/0087 Revision 3

EC type-examination certificate UK/0126/0087 Revision 3 UK/0126/0087 MI-001 EC type-examination certificate UK/0126/0087 Revision 3 issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments

More information

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1 Data sheet / 3.3.2017 - V 2.1 Electronic water meter Q water 5.5 Electronic MID-conform water meter for determining water consumption in water supply systems The electronic water meter Q water 5.5 has

More information

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body Size : Connection Ends : Min Temperature : Max Temperature : DN 50 to 200 Flanged ISO PN 10/16 ( ISO PN16 for DN200 ) 0 C + 50 C Max Pressure : 16 Bars Specifications : Tangential type Dry dial Magnetic

More information

EC type-examination certificate UK/0126/0086 Revision 4

EC type-examination certificate UK/0126/0086 Revision 4 UK/0126/0086 MI-001 EC type-examination certificate UK/0126/0086 Revision 4 issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments

More information

WATER METERS M SERIES WATER METERS INSTALLATION, OPERATION AND MAINTENANCE GUIDE METAL M SERIES WATER METER PLASTIC M SERIES WATER METER

WATER METERS M SERIES WATER METERS INSTALLATION, OPERATION AND MAINTENANCE GUIDE METAL M SERIES WATER METER PLASTIC M SERIES WATER METER WATER METERS M SERIES WATER METERS INSTALLATION, OPERATION AND MAINTENANCE GUIDE METAL M SERIES WATER METER PLASTIC M SERIES WATER METER INTRODUCTION M SERIES WATER METERS INDUSTRY S SMALLEST WATER METERS

More information

EDC communication module

EDC communication module EnergyMetering EDC communication module Water meter clip-on module for secure remote reading for integration of water meters in Smart Metering AMR/AMI Systems All that counts. EnergyMetering EDC communication

More information

Metering systems 0474EN April 2018 Domestic water meter

Metering systems 0474EN April 2018 Domestic water meter 07EN pril 08 Versions for centralization with M-Bus wired GE55Y90 GE55Y95 GE55Y9 GE55Y96 Description Domestic single-jet water meter, with dry dial and pulse output for optional data remoting. This device

More information

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h APPLICATION Ray is a fully electronic multi-jets compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Ray is equipped with 2 temperature sensors.

More information

Brunata Optuna H. Properties. Counter

Brunata Optuna H. Properties. Counter Brunata Optuna H Brunata Optuna H measures energy consumption in large and small heating and cooling systems as well as combined heating and cooling systems. The meter is compact and belongs to the first

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings. MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-R Applications Revenue metering Residential submetering Commercial buildings Leakage detection AMR / AMI and billing Drive-by metering Features Residential

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

2017. 05.17 www.spic.co.kr E-mail : spic@spic.co.kr Contents Company Profile Products AMR System & Case Company 1. Name : Shinhan Precision Co., Ltd. 2. Location : Incheon, Republic of Korea 3. Site :

More information

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS Design IEC870-6 EW447A0100 26757950 2252 00.02 Type440 Umgebungsklasse: C env: 5 C...105 C Δp: 3K...100K q: 1,5m 3 /h q: 0,03m 3 /h q: 3,0m 3 /h M-Bus kwh 2002 er: 5 C...90 C DN15 PN16 Rücklauf Pt500 Kl.

More information

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings. MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-D Applications Revenue metering Residential submetering Commercial buildings Leakage detection AMR / AMI and billing Drive-by metering Features Residential

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

WATERFLUX 3070 Technical Datasheet

WATERFLUX 3070 Technical Datasheet WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone

More information

RAY MC COMPACT ENERGY METER MECHANICAL

RAY MC COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic measuring capsule heat meter, heat and cooling meter or cooling meter with impeller scanning for volume measuring and energy calculation. Highly accurate recording of all billing

More information

The innovative way forward symphonic sensor net radio system

The innovative way forward symphonic sensor net radio system The innovative way forward symphonic sensor net radio system Radio system technology The symphonic sensor net radio system Applications at a glance Heat cost allocation meter doprimo 3 radio net Smoke

More information

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation 07EN March 0 Sanitary water meters GE55- series 00A/ Qualitative error diagram % error 5 0 - - - - -5 Q Q Q Q GE55Y90 GE55Y9 Installation Q [m /h] Q [m /h] Q [m /h] Q [m /h] Description Single-jet dry

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

OIML CERTIFICATE OF CONFORMITY

OIML CERTIFICATE OF CONFORMITY Member State of OIML Germany OIML CERTIFICATE OF CONFORMITY Issuing Authority Name: Address: Person responsible: Physikalisch-Technische Bundesanstalt Bundesallee 100, 38116 Braunschweig Dr. M. Rinker

More information

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite KFS Flap Flow Meter KFS suitable for H, acids, alkalis and gases spring-loaded horizontal or vertical flow direction low pressure loss mainly viscosity independent optional threshold value contacts optional

More information

flowiq 3100 Data sheet

flowiq 3100 Data sheet Data sheet flowiq 3100 Pinpoint accuracy Vacuum sealed construction Drive-by or network Long range Long life Built-in Wireless M-Bus Simple installation Contents Approved meter data 4 Material 4 Technical

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

RAY COMPACT ENERGY METER MECHANICAL

RAY COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Highly accurate recording of all billing data in a heating

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Release A Member of the

Release A Member of the Release 4.02 A T u n e d GRID M e a s u r e A Member of the GRID GRID The OCTAVE Ultrasonic Meters A revolutionary, precise and ultra reliable ultrasonic bulk water meter with no moving parts. With superior

More information

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

FH CMF Coriolis Mass Flow Meters

FH CMF Coriolis Mass Flow Meters FH CMF Coriolis Mass Flow Meters 1. Introduction Coriolis Mass Flow Meters patented and developed by our company (Chinese Patent No. 03119685.3, 03149996.1) are the leading meters for precision flow measurement.

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the

More information

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement Ultrasonic Static Meters Portfolio ULTRAHEAT/ ULTRACOLD and ULTRAWATER The best of Landis+Gyr Ultrasonic Static Meters, for

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

RAY MC COMPACT ENERGY METER MECHANICAL

RAY MC COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic measuring capsule heat meter, heat and cooling meter or cooling meter with impeller scanning for volume measuring and energy calculation. Highly accurate recording of all billing

More information

Precision Double Row Cylindrical Roller Bearings With Tapered Bore

Precision Double Row Cylindrical Roller Bearings With Tapered Bore Roller Bearings With Tapered Bore High precision cylindrical roller bearings are bearings with a low cross section, high load carrying capacity and speed capability. These properties make them particularly

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL Roline L1 Series Humidity - Temperature Transmitters INSTRUCTION MANUAL 20030314 CONTENTS Overview... 3 Operation... 5 Power supply... 5 Operating range and limits... 5 Temperature compensation of the

More information

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range. Ultrasonic flow sensor Compact design D a t a s h e e t Static meter with no moving parts Large dynamic range No wear Exceptionally accurate Longevity TS 27.01 113 OIML R75 Application TS 27.01 109 DS/EN

More information

Physikalisch-Technische Bundesanstalt

Physikalisch-Technische Bundesanstalt R3-0033 Braunschweig und Berlin Member State of OIML Germany OIML CERTIFICATE OF CONFORMITY Issuing Authority Name: Address: Person responsible: Bundesallee 100, 38116 Braunschweig Dr. Gudrun Wendt Applicant

More information

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range. ULTRAFLOW Cooling flow sensor Ultrasonic flow sensor Compact design Static meter with no moving parts Large dynamic range No wear Exceptionally accurate Longevity Application ULTRAFLOW type 65-T is a static

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL M1 Series Humidity - Temperature Transmitter INSTRUCTION MANUAL 20031110 -2- CONTENTS Overview... 3 Operation... 4 Power supply... 4 Operating range and limits... 4 Temperature compensation of the humidity

More information

SonoMeter 31 Energy Meters

SonoMeter 31 Energy Meters SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

Fluxi 2000/TZ. Turbine Gas Meter

Fluxi 2000/TZ. Turbine Gas Meter Fluxi 000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The

More information

thoroughly tried and tested! EWE Tapping Valves A single system for all types of pipes

thoroughly tried and tested! EWE Tapping Valves A single system for all types of pipes thoroughly tried and tested! EWE Tapping Valves A single system for all types of pipes www.ewe-armaturen.de EWE Tapping Fittings high-quality products from Germany EWE tapping fittings are the product

More information

Electromagnetic Flowmeter Comet F

Electromagnetic Flowmeter Comet F Electromagnetic Flowmeter Comet F - Exact measurements - Comfortable calibration with PC - No setup elements - No pressure loss - Periodic cleaning of electrodes - Data backup during power failure - Communication

More information

ULTRAFLOW TS Application OIML R75 DS/EN 1434

ULTRAFLOW TS Application OIML R75 DS/EN 1434 ULTRAFLOW Ultrasonic flow meter Compact design Static meter with no moving parts Large dynamic range No wear Exceptionally accurate Longevity TS 27.01 113 OIML R75 TS 27.01 109 DS/EN 1434 Application ULTRAFLOW

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices BETA Measuring /2 Product overview /3 7KT1 14, 7KT1 53 E-counters /9 7KT1 11, 7KT1 digital measuring devices /11 7KT1 0 analog measuring devices / 7KT5 8 time and pulse counters /14 7KT5 5, 7KT5 6 time

More information

FLOWPET-NX (Oil Service Mechanical Register)

FLOWPET-NX (Oil Service Mechanical Register) FLOWPET-NX (Oil Service Mechanical Register) GENERAL SPECIFICATION GS.No.GBB322-6-E GENERAL Flowpet-NX is an OVAL flowmeter primarily developed for boiler feed water and fuel oil measurement. Field proven

More information

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview Flowmeter SITRANS FUS380 standard Overview Design The 2-track design of SITRANS FUS380 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, transducers/transducer

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Additel 875 Series Dry Well Calibrators

Additel 875 Series Dry Well Calibrators Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect

More information

flowiq 3101 DATA SHEET

flowiq 3101 DATA SHEET Ultrasonic measurement Pinpoint accuracy Longevity Long range Leak detection Vacuum-sealed construction Lead-free and certified to NSF/ANSI61 Electronic ultrasonic meter for cold residential water Ultrasonic

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

Ambient Conditions. Operating Conditions. Pressure

Ambient Conditions. Operating Conditions. Pressure Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

EverBlu. Wireless fixed data collection system

EverBlu. Wireless fixed data collection system Solution EverBlu Wireless fixed data collection system > Automatic daily meter reads > Graphical data analysis > Reliable self-healing wireless mesh network > Suitable for urban, suburban and rural environments

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

Convex Strainers DN PN 80, 100, 200

Convex Strainers DN PN 80, 100, 200 55 Convex Strainers DN 400-1000 PN 80, 100, 200 Designed for protection of compressor rotor bundle against foreign-object damage. Working medium is non-aggressive natural gas and other non-aggressive media

More information

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview SITRANS F flowmeters Siemens AG 009 Overview The -track flowmeter SITRANS FUE380 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks, boiler

More information

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL 20020628 CONTENTS DESCRIPTION... 3 OPERATION... 4 Power Supply...4 Output Range...4 Temperature Operating Range and Temperature Limits...4

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9 Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.

More information

Functional data Factory settings Variable Settings

Functional data Factory settings Variable Settings echnical data sheet Rotary actuator RF-MF(-O) Multifunctional rotary actuator with emergency control for and 3 way control ball valve orque Nm Nominal voltage AC/DC V Control: Modulating DC... V or variable

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Flowmeter SITRANS FUE80 with CT approval Overview The 2-path flowmeter SITRANS FUE80 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks,

More information

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H Level measurement Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H KSR data sheet FLM-H Applications Food and beverage industry Pharmaceutical industry

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2 echnical data sheet Rotary actuator LRA Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage AC... 4 V Control: Open/close or -point echnical data Electrical data Nominal voltage

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

SPECIFICATION. MIMO Dual Band 2.4/5.0GHz. ISM Bands/ZigBee/WLAN/Bluetooth. IEEE n/IEEE ac. High Isolation between Antenna Elements

SPECIFICATION. MIMO Dual Band 2.4/5.0GHz. ISM Bands/ZigBee/WLAN/Bluetooth. IEEE n/IEEE ac. High Isolation between Antenna Elements SPECIFICATION Part No. : MA510.C.CG.005 Product Name : Heavy Duty Screw Mount Antenna MIMO Dual Band 2.4/5.0GHz Features : 2.4GHz/5.0GHz suitable for ISM Bands/ZigBee/WLAN/Bluetooth IEEE.802.11n/IEEE.802.11ac

More information

Magnetic level switches ERH-xx-20

Magnetic level switches ERH-xx-20 edit. II 2015/ page 5 Magnetic level switches ERH-xx-20 Description 3 Level signalling of the medium having minimum density 0,70 g/cm. The basic version, mounted from the top, is available with 92x92mm

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

UFM 800 W, C Ultrasonic flowmeter for water and wastewater KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters

More information

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature

More information

SPECIFICATIONS TO : DUST SENSOR MODULE P/N : DSM501 DSM501 DUST SENSOR MODULE =======================================

SPECIFICATIONS TO : DUST SENSOR MODULE P/N : DSM501 DSM501 DUST SENSOR MODULE ======================================= TO : P/N : DSM501 ======================================= SPECIFICATIONS ======================================== 1. Scope of application This specification is applied to the dust sensor module DSM501

More information

ultego III smart plus

ultego III smart plus Ultrasonic heating and cooling meter ultego III smart plus Residential ultego III smart plus Technical description 32 22 101 001 a Date: 07.04.2017 ista Middle East FZE Outstanding features 2/26 Outstanding

More information

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160 Mechatronic pressure measurement Absolute pressure gauge with output signal For the process industry Models APGT43.100 and APGT43.160, NS 100 and 160 k Applications for further approvals see page 4 WIKA

More information

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version Mechatronic temperature measurement Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version WIKA data sheet TV 17.01 for further approvals see page 6 Applications

More information

Standard Bourdon tube pressure gauges EN 837-1

Standard Bourdon tube pressure gauges EN 837-1 Standard Bourdon tube pressure gauges EN 871 Application For gaseous and liquid media which are not highly viscous, do not crystallize and are not aggressive to copper alloys. For measuring gas or vapour,

More information

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation echnical data sheet EP..R-R6+BAC Characterised control valve with sensor-operated flow control, 6-way, Internal thread, PN 16 (EPIV) Nominal voltage AC/DC 24 V Control modulating, communicative wo sequences

More information