Image Analysis for Fluorescence

Size: px
Start display at page:

Download "Image Analysis for Fluorescence"

Transcription

1 Image Analysis for Fluorescence

2 Terminology Table Image Analysis Macro Colocalization Intensity Dye AFI The extraction of meaningful information from digital images by means of digital image processing techniques. A macro is a pre-saved set of input parameters that have been adjusted for a specific application. Analysis technique that determines the contribution of each dye at every pixel location. Intensity of a pixel is proportional to the dye emission strength in the same area. Intensity ranges from 0 (no detectable signal) up to 1023 (very strong signal) for images captured with a 10 bit setting. Analysis intensity input parameters (min and max) are from 0-1 representing the intensity scale from 0-100%. Dye is the name of the fluorescent dye. There is no need to enter color values to deconvolve dyes for Aperio s FL algorithms. Fluorescent images taken with Aperio s ScanScope FL are separate monochrome images per dye that are pseudo-colored and fused to make one image. Aperio Fused Image -The AFI file is a special type of image file. It is a composite file that points to the separate channel images that make up the fused image. Page 2

3 FL Image Analysis Illustrated Image Analysis extracts meaningful data: Analyzing fluorescent digital slides helps you quantitate the area of staining of a particular biomarker. Image analysis tools help to automate such repetitive processes and provide quantitative data that is accurate and repeatable, telling you more about each slide beyond the capabilities of manual microscopy. Aperio s FL image analysis can provide valuable area and intensity data and answer questions such as: How much area of the tissue is stained for a particular biomarker? What is the average intensity of the biomarker staining throughout the tissue or region of interest? Do multiple biomarkers co-localize in the tissue, or in the cells, and if so, to what extent? Image Analysis tools can present a markup image to highlight analysis results. Original Markup Page 3

4 FL Image Analysis Illustrated How Image Analysis works: Apply an algorithm directly to the whole digital slide image or selected region of the digital slide image. Aperio ScanScope FL images are comprised of separate images (one for each fluorescent dye on the slide) resulting in an Aperio Fused Image or AFI. Since images are captured during scanning as monochrome images and pseudo-colored based on a reference chart (by the dye s name) pixels are already separated by the fluorescent dye or dye. Image analysis algorithms measures pixel intensity (proportional to dye emission) to determine the average intensity of single dyes and when dye appear together. Image analysis algorithms count pixels to determine: Area of analysis. The total area of staining (all dyes). The area of single dyes. The area of dyes appearing in combination (in the same pixel location) Intensity: 0 = signal undetectable 1023 = very strong signal Image analysis scales the intensity range 0-1 (0-100%) DAPI CY3 Pixel CY5 Page 4

5 Aperio Image Analysis Tools Area Quantification Positive Pixel Count FL Area Quantification FL Positive Pixel Count Color Deconvolution Colocalization FDA Cleared: Her2 510(k) & ER/PR 510(k) Note: User guides, manuals training presentations and demo videos are available on Aperio s Member Center at: members.aperio.com Cell Quantification Nuclear Membrane Object Identification Microvessel Analysis Rare Event Detection Each algorithm has a set of control parameters that allow you to tailor it to your specific needs. Several of Aperio's image analysis algorithms are FDA cleared for specific clinical applications, and are intended for research use for other applications. Note that each algorithm has it s own user guide. Please see the Intended Use section of the respective user guide for the specific cleared applications you wish to use and for details on in vitro diagnostic use. Page 5

6 Aperio Image Analysis Tools Aperio Image Analysis Algorithm Combined Image Analysis Tool (Algorithm + Genie ) A smart tissue classifier that recognizes significant tissue components coupled with an FL image analysis algorithm. Genie Histology Pattern Recognition Genie is intended for research use only. Genie is not covered in Image Analysis 101 for Fluorescence. Please see TRN-0017 for user related course content. Page 6

7 Aperio Image Analysis FL Tools Positive Pixel Count FL: Quantifies the area and intensity of a selected fluorescent dye. Area and area fraction analysis, for example, analysis of fluorescent digital slides showing amyloid plaque myelin and nuclei. Licensed without fee with other Aperio software. Amyloid Plaque Quantification Original Markup Page 7

8 Aperio Image Analysis FL Tools Area Quantification FL: Quantifies the area and intensities of up to 3 dyes. Area and colocalized marker analysis, for example, analysis of fluorescent digital slides showing gene and protein expressions. Pancreatic Islet Protein Expression Original Markup Page 8

9 Aperio Image Analysis Tools Histology Pattern Recognition Genie: A smart tissue classifier that recognizes significant tissue components and aids analysis. Original Islet Exocrine Classification Quantification Page 9

10 Viewing Fluorescence Slides Viewing Fluorescence Slides in ImageScope Images from the ScanScope FL are grayscale images, pseudo-colored during the scanning process. ImageScope offers a full range of fluorescence features for ScanScope FL fused (composite) Images: Change the display color for each channel image. Adjust brightness, contrast, and gamma (viewing the results on the image and on a histogram display). Hide image channels or display them in grayscale. Adjust registration between channels. Note: Modifying viewing options in ImageScope does not affect the analysis. Channels Hidden Original Color Adjustments Channel in Grayscale Page 10

11 Performing Analysis Selecting Areas to Analyze Analyze entire digital slide or selected areas. Use ImageScope drawing tools to select or exclude areas to analyze. Pen - draw free-form area of interest. Negative Pen draw free-form area to exclude from analysis. Rectangle draw a rectangular area of interest. View annotation information in ImageScope s Annotations window. Page 11

12 Performing Analysis Methods to Run Analysis In most cases, it is expected that a digital slide will be opened in Spectrum. For this training, all images will be opened in Spectrum. ImageScope Analysis Open a local digital slide image (that is, an image on your workstation or on the network where your workstation can see it via Microsoft file sharing) and analyze using ImageScope. Use ImageScope to connect to an image on an Aperio ImageServer. Spectrum Plus Analysis Open an image from Spectrum and initiate analysis using a Spectrum licensed algorithm macro. Batch Analysis Analyze a batch of digital slide images that reside on the ImageServer by selecting multiple images and using Spectrum s Analyze command Page 12

13 ImageScope Image Analysis Analysis Workflow Using an Existing Macro Run analysis using a macro with input parameters already tuned for your application. Ready to analyze an image. Licensed Image Analysis Algorithms on Spectrum Select view menu>analysis, choose macro and analysis options and click Analyze. View results. Intensity Spectrum Other Inputs Dye Macros are pre-saved sets of algorithm input parameters that have been adjusted for specific image analysis applications. Page 13

14 ImageScope Image Analysis Analysis Workflow Modifying an Existing Macro Select an existing macro, modify the input parameters for your application and save. Ready to analyze an image. Licensed Image Analysis Algorithms on Spectrum Select view menu>analysis, select macro name and click Test button. Select Select view view menu>analysis, menu>analysis, choose choose macro macro and and analysis analysis options options and and click click Analyze. Analyze. View results. Test Window Adjust input parameters for your slide/application. Use Tuning window as needed. Click Run to analyze and get test results. NO Are the results & markup acceptable? YES Click Save macro from test window. Spectrum Page 14

15 ImageScope Image Analysis Analysis Workflow Creating a New Macro Use this method if the algorithm has not been used and saved as a macro. Use to create a macro using the algorithm s default parameters. Ready to analyze an image. Select an algorithm to modify Licensed Image Analysis Algorithms on Spectrum Select view menu>analysis and click Create button. Select view menu>analysis, Select view choose menu>analysis, macro and choose analysis macro options and and analysis click Analyze. options and View click results. Analyze. Test Window Adjust input parameters for your slide/application. Use Tuning window as needed. Click Run to analyze and get test results. NO Are the results & markup acceptable? YES Click Save macro from test window. Spectrum Page 15

16 ImageScope Image Analysis Analysis Window When performing analysis on an image opened from Spectrum, the Algorithm Server Job displays registered macros. Go to the Test window to modify input parameters or click Create to make a new Macro. List of macros Analysis options Analysis Buttons Test modify existing macro for selected algorithm and test before saving. Create creates new macro based on the original algorithm. Analyze run analysis. Cancel cancel current analysis job. Page 16

17 ImageScope Image Analysis Test Window test out input parameters before saving them Tune algorithm input parameters and view results, select outputs displayed in Spectrum and save settings as a new macro. List of input parameters Select Algorithm select to load an algorithm with its default settings. Import Macro import an image analysis macro. Save Macro save an image analysis macro to Spectrum. Note: If image was opened and analyzed locally, an Export Macro button will appear instead on the Save button. Turn on result plots here! Analysis options List of output parameters (to display in Spectrum) Tune Allows operators to see instant markup up results in a separate window and results in the annotations window while adjusting the algorithm s input parameters. Run run analysis. Page 17

18 ImageScope Image Analysis Creating New Macros from your licensed algorithms Only users with the appropriate Spectrum administrator permissions can create new macros and register them in Spectrum. After opening a digital slide in ImageScope, open the View menu and select Analysis. Click Create, the Select an Algorithm window appears. Select the Algorithm you want to create a macro for, the Analysis window appears. Note: ImageScope may highlight the last selected macro in this window; ignore this and click Create. Note: Algorithms selected for this list will have their default input parameters. Page 18

19 ImageScope Image Analysis Creating New Macros Modify the parameters. Use the Tuning window to see the effect of the parameter changes. Run analysis and continue to adjust the inputs until desired results are achieved. Modify input parameters Remember, the output button allows you to select the results that will appear in Spectrum. Tuning window Page 19

20 ImageScope Image Analysis Creating New Macros Select Save Marco button. Name the macro with a naming convention that helps identify it and its application. Using the same name as an existing macro will display a prompt asking if you want to overwrite the existing macro. Once saved, your new macro will appear in the Analysis window s list of macros. Page 20

21 ImageScope Image Analysis More on the Algorithm Tuning Window Quickly see the results of analyzing an area of an image or test changes made to the algorithm parameters. Toggle on/off markup Page 21

22 ImageScope Image Analysis More on the Algorithm Tuning Window As the parameters are changed, the Tuning window will display the markup image for current parameters. The Annotations window displays the numerical results in a Tuning Layer. Immediately see results after parameter changes! Note: Upon closing the Tuning window, the Tuning Layer disappears. Analysis results from the tuning layer cannot be saved. After parameter change Page 22

23 ImageScope Image Analysis Analysis Parameters Inputs Dye(s) Typing in the Dye name points the algorithm to the correct component image of the AFI (or dye color channel). Intensity Dye intensity minimum and maximum values determine the intensity range to be analyzed. Other Attributes: Markup Image Type Color coding of pixels to display area of dye (single dye and or combination of dyes together). Display Plots - Select to display result plots and set histogram start/end values and number of bins. ImageScope Inputs entered in ImageScope from the Test window. Intensity -OR- Analysis Inputs Other Attributes Dye(s) Spectrum Inputs from saved macro or from the default algorithm. Analysis Output or Results Page 23

24 ImageScope Image Analysis Analysis Parameters Outputs (Analysis Results) Area and Intensity Results Total area of analysis (mm 2 ). Total stained area (mm 2 ). Total area of each dye (mm 2 ). Percent for each dye. Average intensity for each dye. Percent and intensity colocalized dye results. Result plots. Markup A color coded layer displayed over the area of analysis that corresponds with the analysis results. Displays only the pixels that fall within the set intensity range. The markup layer displays colors that match the pseudo-colors used to color the grayscale images in the scanning process. Intensity Other Attributes Analysis Outputs Dye(s) Analysis Output or Results ImageScope Analysis results displayed in ImageScope in the Annotations window. Spectrum Analysis saved in Spectrum (If performed server-side). Sever- side analysis: When an image is accessed from Spectrum and analyzed using an Spectrum licensed algorithm. Page 24

25 ImageScope Image Analysis Analysis Results - ImageScope Layer Attributes - results for entire layer (all regions analyzed). Layer Regions - results per region analyzed. View result plots - click the Display Plots button in the Layer Attributes pane. Export from ImageScope - click the Export button in the Layer Attributes pane to export to an Excel spreadsheet. Page 25

26 ImageScope Image Analysis Analysis Results - Spectrum Spectrum analysis results analysis column must be displayed in the Digital Slide table to view the analysis results. Select image checkbox and click Export Data link to export data from Spectrum. Analysis Column Click Export Data Select image for data export Page 26

27 Positive Pixel Count FL Positive Pixel Count FL Positive Pixel Count FL looks for pixels for the dye specified within the intensity range set (minimum and maximum). Outputs: Total area of analysis (mm 2 ). Total area of specified dye (mm 2 ). Mean intensity of specified dye. The markup image displays only the pixels that fall within the set intensity range for the specified dye. The markup image color matches the pseudo-color used for that dye in the scanning process. Original Markup Page 27

28 Positive Pixel Count FL Positive Pixel Count FL Inputs - Workflow 1. Enter dye name. Enter fluorescent dye name. 2. Set intensity thresholds. Set the dye intensity minimum and maximum intensity thresholds. Page 28

29 Positive Pixel Count FL Positive Pixel Count FL Inputs Input parameters allow the user to identify the fluorescent dye or dye the and intensity thresholds. The user enters the dye as it appears in the ImageScope Image Fusion Adjustments window. This specifies the target color channel/component image of the AFI for analysis. Default for ScanScope images Genie parameters Dye name and intensity thresholds Page 29

30 Positive Pixel Count FL Positive Pixel Count FL Analysis Results Analysis results are viewed from the Annotations Window in ImageScope. PPC analysis results are area based quantification and intensity values. If running analysis in ImageScope, a false color Markup image can be generated. Positive Pixel Count FL results: Total area of analysis, the total area of specified dye and its mean intensity. Results are color coded to match the dye s pseudocolor used in the scanning process Input parameters are always saved with the analysis results. Page 30

31 Area Quantification FL Area Quantification FL Quantifies the area and intensity of each dye and within combinations of dyes. Good for analysis of colocalized markers. Quantification FL analysis calculates the contribution of each dye at every image pixel as either part of a single dye or representing a dye combination. Outputs: Total Analyzed Area Total Stained Area Percent area of dye and average intensity (for single dyes and dye combinations). Original Dye -3 (only) All Dyes Dyes 1+2 Dye -2 (only) Pixels where dyes appear alone w/o other dyes All pixels where dyes appear (alone and with other dyes) Pixels where dyes appear only in specified combinations Page 31

32 Area Quantification FL Area Quantification FL Tuning Area Quantification FL Tuning Markups All Dye 1, Markup displays image channel for dye 1 only (in grayscale) and false colors only the pixels within the intensity ranges. All Dye 2, Markup displays image channel for dye 2 only (in grayscale) and false colors only the pixels within the intensity ranges. All Dye 3, Markup displays image channel for dye 3 only (in grayscale) and false colors only the pixels within the intensity ranges. DAPI Alexa Fluor 532 Alexa Fluor 647 Original Tuning All Dye -1 Tuning All Dye -2 Tuning All Dye -3 Page 32

33 Area Quantification FL Area Quantification FL Inputs - Workflow 1. Enter the number of dyes, and dye names. Enter the number of dyes (1-3). Enter the fluorescent dye names. 2. Set intensity thresholds. Set the dye intensity minimum and maximum intensity thresholds for each dye. 3. Set markup image type and enter plot values. Select the Markup Image Type. Enter plots start and end values and the number of bins. Page 33

34 Area Quantification FL Area Quantification FL Inputs Number of Dyes to Colocalize - 1, 2, 3 Dye 1, 2, 3 - Enter the dye name displayed in ImageScope s Image Fusion Adjustments window for each dye you want to include as part of the analysis. Intensity Thresholds - Min and Max threshold and # of bins for dyes 1, 2 & 3. Markup Image Type Tuning Dyes (1, 2, 3) Colocalized All Dyes Colocalized 1 only, 2 only, 3 only, 1+2 only, 1+3 only, 2+3 only, Display Plots - View result plots. Histogram Start/End Values Select Mark-up Image Type Default Dyes: Dye (1) = DAPI Color (2) = FITC Color (3) = TRITC Intensity Lower and Upper Threshold parameters Pick number of dyes. Select Yes to display Plots with results. Enter Start, End values and number of Bins Page 34

35 How to access Please contact Dr Maria Sarris if you wish to use this image analysis algorithm. All algorithms apart from the Positive Pixel Count are licensed and need to be installed on your workstation (please note: charges apply). Step 1: Extract the region at full resolution that you want test on your desktop. Extracting Image Using the Extraction Tool to remove a select region of the active image. Click on in the toolbar. Place your cursor on the digital slide. Click and drag a rectangle on the screen to capture the area: Choose output File location Choose Output/Compression File type Click Extract Step 2: Open image in Imagescope Step 3: Go to VIEW then ANALYSIS Step 4: Select Algorithm and then click on TEST Step 5: Make your adjustments (optimise algorithm) Step 6: When satisfied with your adjustments click EXPORT MACRO Step 7: Save to your desktop with your name and original algorithm name and version eg SARRIS Nuclear V9 Step 8: Once the algorithm is saved please m.sarris@unsw.edu.au. The algorithm will on the server in the Spectrum Analysis dropdown menu within 24 hrs. Page 35

Positive Pixel Count Algorithm. User s Guide

Positive Pixel Count Algorithm. User s Guide Positive Pixel Count Algorithm User s Guide Copyright 2004, 2006 2008 Aperio Technologies, Inc. Part Number/Revision: MAN 0024, Revision B Date: December 9, 2008 This document applies to software versions

More information

Image Viewing. with ImageScope

Image Viewing. with ImageScope Image Viewing with ImageScope ImageScope Components Use ImageScope to View These File Types: ScanScope Virtual Slides.SVS files created when the ScanScope scanner scans glass microscope slides. JPEG files

More information

Algorithm User Guide:

Algorithm User Guide: Algorithm User Guide: Positive Pixel Count Use the Aperio algorithms to adjust (tune) the parameters until the quantitative results are sufficiently accurate for the purpose for which you intend to use

More information

ImageScope. User s Guide

ImageScope. User s Guide ImageScope User s Guide Copyright 2006 2011, Aperio Technologies, Inc. Part Number/Revision: MAN 0001, Revision I Date: 5 January 2011 This document applies to software versions Release 11 and later. All

More information

Positive Pixel Count Algorithm

Positive Pixel Count Algorithm The Pathology Company Positive Pixel Count Algorithm User s Guide MAN-0024, Revision E 1 December 2014 Positive Pixel Count Algorithm User s Guide This document applies to eslide Manager Release 12.2 and

More information

inform ADVANCED IMAGE ANALYSIS SOFTWARE inform User Manual

inform ADVANCED IMAGE ANALYSIS SOFTWARE inform User Manual inform ADVANCED IMAGE ANALYSIS SOFTWARE inform User Manual Notice The information in this document is subject to change without notice and should not be construed as a commitment by PerkinElmer, Inc. PerkinElmer

More information

Definiens. Tissue Studio 4.2. Tutorial 1: Composer and Nuclear Markers

Definiens. Tissue Studio 4.2. Tutorial 1: Composer and Nuclear Markers Definiens Tissue Studio 4.2 Tutorial 1: Composer and Nuclear Markers Tutorial 1: Composer and Nuclear Markers Imprint and Version Copyright 2015 Definiens AG. All rights reserved. This document may be

More information

User Reference Manual

User Reference Manual User Reference Manual IN SITU HYBRIDIZATION QUANTIFICATION (for research purposes only) Contents Overview... 3 System Requirements... 3 Compatible File Formats... 3 Input Parameters... 4 Output Parameters...

More information

MAKE SURE YOUR SLIDES ARE CLEAN (TOP & BOTTOM) BEFORE LOADING DO NOT LOAD SLIDES DURING SOFTWARE INITIALIZATION

MAKE SURE YOUR SLIDES ARE CLEAN (TOP & BOTTOM) BEFORE LOADING DO NOT LOAD SLIDES DURING SOFTWARE INITIALIZATION Olympus VS120-L100 Slide Scanner Standard Operating Procedure Startup 1) Red power bar switch (behind monitor) 2) Computer 3) Login: UserVS120 account (no password) 4) Double click: WAIT FOR INITIALIZATION

More information

Aperio ImageScope. User s Guide. For research use only. Not for use in diagnostic procedures.

Aperio ImageScope. User s Guide. For research use only. Not for use in diagnostic procedures. Aperio ImageScope User s Guide For research use only. Not for use in diagnostic procedures. MAN-0001, Revision Q 5 December 2017 Aperio ImageScope User s Guide This document applies to Aperio eslide Manager

More information

InScape: Making Virtual Pathology a Reality

InScape: Making Virtual Pathology a Reality InScape: Making Virtual Pathology a Reality Sally S. Agersborg, M.D., Ph.D. Quest Diagnostics, Nichols Institute San Juan Capistrano, CA Company Overview Quest Diagnostics, Nichols Institute the world

More information

LSM 780 Confocal Microscope Standard Operation Protocol

LSM 780 Confocal Microscope Standard Operation Protocol LSM 780 Confocal Microscope Standard Operation Protocol Basic Operation Turning on the system 1. Sign on log sheet according to Actual start time 2. Check Compressed Air supply for the air table 3. Switch

More information

MEDICAL EDUCATION TECHNOLOGY

MEDICAL EDUCATION TECHNOLOGY Snipping Tool Overview The Snipping Tool provides a way to capture images from your display screen and imbed them in documents you develop. This is especially useful in Histopathology lab, since it allows

More information

Batch Counting of Foci

Batch Counting of Foci Batch Counting of Foci Getting results from Z stacks of images. 1. First it is necessary to determine suitable CHARM parameters to be used for batch counting. First drag a stack of images taken with the

More information

DataCapture Transcript Module Getting Started Guide

DataCapture Transcript Module Getting Started Guide DataCapture Transcript Module Getting Started Guide Version: 6.6 Written by: Product Documentation, R&D Date: February 2011 ImageNow and CaptureNow are registered trademarks of Perceptive Software, Inc.

More information

IncuCyte ZOOM Scratch Wound Processing Overview

IncuCyte ZOOM Scratch Wound Processing Overview IncuCyte ZOOM Scratch Wound Processing Overview The IncuCyte ZOOM Scratch Wound assay utilizes the WoundMaker-IncuCyte ZOOM-ImageLock Plate system to analyze both 2D-migration and 3D-invasion in label-free,

More information

Supplemental Reference Guide

Supplemental Reference Guide Supplemental Reference Guide QuantiGene ViewRNA mirna ISH Cell Assay P/N 19167 Rev.A 120623 For research use only. Not for use in diagnostic procedures. Trademarks Affymetrix and, and QuantiGene are trademarks

More information

Cedex XS System Customer Training Guide

Cedex XS System Customer Training Guide Cedex XS System Customer Training Guide For life science research only. Not for use in diagnostic procedures. Table of Contents Prologue 5 I Revision History... 5 II Trademarks... 5 III Intended Use...

More information

Zeiss 780 Training Notes

Zeiss 780 Training Notes Zeiss 780 Training Notes Turn on Main Switch, System PC and Components Switches 780 Start up sequence Do you need the argon laser (458, 488, 514 nm lines)? Yes Turn on the laser s main power switch and

More information

LSM 710 Confocal Microscope Standard Operation Protocol

LSM 710 Confocal Microscope Standard Operation Protocol LSM 710 Confocal Microscope Standard Operation Protocol Basic Operation Turning on the system 1. Switch on Main power switch 2. Switch on System / PC power button 3. Switch on Components power button 4.

More information

IncuCyte ZOOM Fluorescent Processing Overview

IncuCyte ZOOM Fluorescent Processing Overview IncuCyte ZOOM Fluorescent Processing Overview The IncuCyte ZOOM offers users the ability to acquire HD phase as well as dual wavelength fluorescent images of living cells producing multiplexed data that

More information

1. What is SENSE Batch

1. What is SENSE Batch 1. What is SENSE Batch 1.1. Introduction SENSE Batch is processing software for thermal images and sequences. It is a modern software which automates repetitive tasks with thermal images. The most important

More information

Leica SPEII confocal microscope. Short Manual

Leica SPEII confocal microscope. Short Manual Leica SPEII confocal microscope Short Manual Switching ON sequence: 1. Turn on the Workstation under the bench (top, far right). 2. Turn on the Supply Unit - Laser box (big green switch first and then

More information

Nikon SIM-E & A1-R System

Nikon SIM-E & A1-R System Nikon SIM-E & A1-R System USER GUIDE LSU Health Sciences Center Shreveport Research Core Facility June 01 2017 Chaowei Shang 1 Table of Content 1. Start Up the System... Page 3 Hardware and microscope

More information

CellSelect Software User Manual

CellSelect Software User Manual CellSelect Software User Manual Cat. No. 640000 (111617) 1290 Terra Bella Avenue, Mountain View, CA 94043, USA U.S. Technical Support: techus@takarabio.com United States/Canada 800.662.2566 Asia Pacific

More information

Calculate Ratiometric FRET-Images with the FRET-Image-Script

Calculate Ratiometric FRET-Images with the FRET-Image-Script Tutorial Calculate Ratiometric FRET-Images with the FRET-Image-Script Summary This tutorial shows step-by-step, how the "FRET Image" script of SymPhoTime 64 can be used to calculate pixel-by-pixel the

More information

Introduction to Image Analysis with

Introduction to Image Analysis with Introduction to Image Analysis with PLEASE ENSURE FIJI IS INSTALLED CORRECTLY! WHAT DO WE HOPE TO ACHIEVE? Specifically, the workshop will cover the following topics: 1. Opening images with Bioformats

More information

Center for Microscopy and Image Analysis Axio Scan.Z1 Operating Manual

Center for Microscopy and Image Analysis Axio Scan.Z1 Operating Manual No index entries found. Center for Microscopy and Image Analysis Axio Scan.Z1 Operating Manual Table of contents 1. Starting procedure... 3 1.1. Turn on hardware... 3 1.2. Starting ZEN blue... 4 2. Load

More information

LSM 800 Confocal Microscope Standard Operation Protocol

LSM 800 Confocal Microscope Standard Operation Protocol LSM 800 Confocal Microscope Standard Operation Protocol Turning on the system 1. Switch on the Main switch (labeled 1 and 2 ) mounted on the wall. 2. Turn the Laser Key (labeled 3 ) 90 clockwise for power

More information

THEORY AND APPROACHES TO AUTOMATED IMAGE ANALYSIS IN DIGITAL PATHOLOGY

THEORY AND APPROACHES TO AUTOMATED IMAGE ANALYSIS IN DIGITAL PATHOLOGY THEORY AND APPROACHES TO AUTOMATED IMAGE ANALYSIS IN DIGITAL PATHOLOGY Kyle Takayama, MS Charles River Laboratories EVERY STEP OF THE WAY EVERY STEP OF THE WAY MORPHOMETRY Measurements or counts performed

More information

In our previous lecture, we understood the vital parameters to be taken into consideration before data acquisition and scanning.

In our previous lecture, we understood the vital parameters to be taken into consideration before data acquisition and scanning. Interactomics: Protein Arrays & Label Free Biosensors Professor Sanjeeva Srivastava MOOC NPTEL Course Indian Institute of Technology Bombay Module 7 Lecture No 34 Software for Image scanning and data processing

More information

Thank you for using Delta2D, the software package with leading technology for easy and reliable analysis of 2D gel images.

Thank you for using Delta2D, the software package with leading technology for easy and reliable analysis of 2D gel images. Title 2 3 Copyright 2000-2008 DECODON GmbH. DECODON makes no representations, express or implied, with respect to this documentation or the software it describes, including without limitations, any implied

More information

ThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer

ThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer ThermaViz The Innovative Two-Wavelength Imaging Pyrometer Operating Manual The integration of advanced optical diagnostics and intelligent materials processing for temperature measurement and process control.

More information

Digital Pathology and Image Analysis. Queen s University Department of Pathology and Molecular Medicine Shakeel Virk

Digital Pathology and Image Analysis. Queen s University Department of Pathology and Molecular Medicine Shakeel Virk Digital Pathology and Image Analysis Queen s University Department of Pathology and Molecular Medicine Shakeel Virk Outline Digital Pathology and Image Analysis capabilities at Queen s Laboratory for Molecular

More information

Takeoff Guide Tutorial to get started with the AxioVision Imaging System (Based on Release 4.8 June 2009)

Takeoff Guide Tutorial to get started with the AxioVision Imaging System (Based on Release 4.8 June 2009) Takeoff Guide Tutorial to get started with the AxioVision Imaging System (Based on Release 4.8 June 2009) This Takeoff Guide has been prepared for Carl Zeiss by Imaging Associates Ltd. www.imas.co.uk Copyright

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Zeiss LSM 510 M eta Confocal M icroscope OPERATING INSTRUCTIONS Starting the System: 1. Turn the black knob on the laser box one-quarter turn from Off to On. You will hear the laser cooling mechanisms

More information

Guide to Confocal 5. Starting session

Guide to Confocal 5. Starting session Guide to Confocal 5 Remember that when booking and before starting session you can check for any problems at https://www.bris.ac.uk/biochemistry/uobonly/cif/index.html Starting session Switch on microscope

More information

Sante FFT Imaging Copyright 2018 Santesoft, all rights reserved

Sante FFT Imaging Copyright 2018 Santesoft, all rights reserved Sante FFT Imaging Copyright 2018 Santesoft, all rights reserved Table of Contents About the program... 2 System Requirements... 2 The Fourier transform... 3 The user interface... 5 Customize the toolbar...

More information

Automated Cellular Imaging and Analysis System

Automated Cellular Imaging and Analysis System Automated Cellular Imaging and Analysis System CELLULAR IMAGING AND ANALYSIS FOR SCREENING AUTOMATED ACQUISITION AUTOMATED ANALYSIS HIGH RESOLUTION The ImageXpress TM 5000A automated cellular imaging and

More information

Arcturus XT Laser Capture Microdissection System AutoScanXT Software Module. User Manual

Arcturus XT Laser Capture Microdissection System AutoScanXT Software Module. User Manual Arcturus XT Laser Capture Microdissection System AutoScanXT Software Module User Manual For Research Use Only. Not intended for any animal or human therapeutic or diagnostic use. Information in this document

More information

AMEEL Digitization Manual: Part 5, Phase Two Processing in Photoshop 1

AMEEL Digitization Manual: Part 5, Phase Two Processing in Photoshop 1 AMEEL Digitization Manual: Part 5, Phase Two Processing in Photoshop 1 Phase Two Processing: Photoshop The Phase One processing in BCS-2 produces a series of page images tightly cropped to include only

More information

Guide to Configuring Vectra 3 and inform for Compatibility with the DISCOVERY 5-Plex Procedure from Roche Tissue Diagnostics

Guide to Configuring Vectra 3 and inform for Compatibility with the DISCOVERY 5-Plex Procedure from Roche Tissue Diagnostics Vectra 3 Automated Quantitative Pathology Imaging System Guide to Configuring Vectra 3 and inform for Compatibility with the DISCOVERY 5-Plex Procedure from Roche Tissue Diagnostics Introduction Follow

More information

Getting Started. with Easy Blue Print

Getting Started. with Easy Blue Print Getting Started with Easy Blue Print User Interface Overview Easy Blue Print is a simple drawing program that will allow you to create professional-looking 2D floor plan drawings. This guide covers the

More information

IncuCyte ZOOM Scratch Wound Processing Overview

IncuCyte ZOOM Scratch Wound Processing Overview IncuCyte ZOOM Scratch Wound Processing Overview The IncuCyte ZOOM Scratch Wound assay utilizes the WoundMaker-IncuCyte ZOOM-ImageLock Plate system to analyze both 2D-migration and 3D-invasion in label-free,

More information

Excel Lab 2: Plots of Data Sets

Excel Lab 2: Plots of Data Sets Excel Lab 2: Plots of Data Sets Excel makes it very easy for the scientist to visualize a data set. In this assignment, we learn how to produce various plots of data sets. Open a new Excel workbook, and

More information

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING Operations Guide Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING Nikon Eclipse 90i Operations Guide STARTUP Startup Powering Up Fluorescence

More information

Zeiss Axio Imager.A1 manual

Zeiss Axio Imager.A1 manual Zeiss Axio Imager.A1 manual Power-up protocol 1. Mercury lamp 2. Power strip on shelf 3. Computer The Mercury lamp should always be first-on and last-off. This prevents any electrical surges caused by

More information

TN378: Openlab Module - FRET. Topic. Discussion

TN378: Openlab Module - FRET. Topic. Discussion TN378: Openlab Module - FRET Topic This technical note describes the use of the Openlab FRET module in Openlab 3.1.4 and higher. Users of Openlab Server systems will require Openlab Server 3.0.1 or higher

More information

CHAPTER1: QUICK START...3 CAMERA INSTALLATION... 3 SOFTWARE AND DRIVER INSTALLATION... 3 START TCAPTURE...4 TCAPTURE PARAMETER SETTINGS... 5 CHAPTER2:

CHAPTER1: QUICK START...3 CAMERA INSTALLATION... 3 SOFTWARE AND DRIVER INSTALLATION... 3 START TCAPTURE...4 TCAPTURE PARAMETER SETTINGS... 5 CHAPTER2: Image acquisition, managing and processing software TCapture Instruction Manual Key to the Instruction Manual TC is shortened name used for TCapture. Help Refer to [Help] >> [About TCapture] menu for software

More information

Manual. Cell Border Tracker. Jochen Seebach Institut für Anatomie und Vaskuläre Biologie, WWU Münster

Manual. Cell Border Tracker. Jochen Seebach Institut für Anatomie und Vaskuläre Biologie, WWU Münster Manual Cell Border Tracker Jochen Seebach Institut für Anatomie und Vaskuläre Biologie, WWU Münster 1 Cell Border Tracker 1. System Requirements The software requires Windows XP operating system or higher

More information

Image Processing Tutorial Basic Concepts

Image Processing Tutorial Basic Concepts Image Processing Tutorial Basic Concepts CCDWare Publishing http://www.ccdware.com 2005 CCDWare Publishing Table of Contents Introduction... 3 Starting CCDStack... 4 Creating Calibration Frames... 5 Create

More information

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA HANDOUT LECTURE-31 MICROARRAY WORK-FLOW: IMAGE SCANNING AND DATA PROCESSING Slide 1: This module contains the summary of the discussion with Mr. Pankaj Khanna, an application specialist from Spinco Biotech,

More information

Volocity Tutorial Creating a Measurement Protocol in Volocity Software

Volocity Tutorial Creating a Measurement Protocol in Volocity Software TUTORIAL NOTE Cellular Imaging and Analysis Volocity Tutorial Creating a Measurement Protocol in Volocity Software This tutorial will illustrate the process of creating a Measurement Protocol in Volocity

More information

Excel Tool: Plots of Data Sets

Excel Tool: Plots of Data Sets Excel Tool: Plots of Data Sets Excel makes it very easy for the scientist to visualize a data set. In this assignment, we learn how to produce various plots of data sets. Open a new Excel workbook, and

More information

Introduction to BioImage Analysis

Introduction to BioImage Analysis Introduction to BioImage Analysis Qi Gao CellNetworks Math-Clinic core facility 22-23.02.2018 MATH- CLINIC Math-Clinic core facility Data analysis services on bioimage analysis & bioinformatics: 1-to-1

More information

Cell Biology and Bioimaging Core

Cell Biology and Bioimaging Core Cell Biology and Bioimaging Core Leica TCS SP5 Operating Instructions Starting up the instrument 1. First, log in the log book located on the confocal desk. Include your name, your lab s PI, an account

More information

High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems

High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems High-sensitivity optical molecular imaging and high-resolution digital X-ray In-Vivo Imaging Systems In vivo imaging solutions available in several packages Carestream Molecular Imaging offers a selection

More information

FLIR Tools for PC 7/21/2016

FLIR Tools for PC 7/21/2016 FLIR Tools for PC 7/21/2016 1 2 Tools+ is an upgrade that adds the ability to create Microsoft Word templates and reports, create radiometric panorama images, and record sequences from compatible USB and

More information

DSU Spinning Disk Confocal and Slidebook 4.2 Quick Guide Light Microscopy Core Facility University of Chicago Vers 0.

DSU Spinning Disk Confocal and Slidebook 4.2 Quick Guide Light Microscopy Core Facility University of Chicago Vers 0. DSU Spinning Disk Confocal and Slidebook 4.2 Quick Guide Light Microscopy Core Facility University of Chicago Vers 0.8, February 2007 By: Vytas Bindokas, Ph.D. Core Director 2 The DSU system is optimized

More information

Motic Live Imaging Module. Windows OS User Manual

Motic Live Imaging Module. Windows OS User Manual Motic Live Imaging Module Windows OS User Manual Motic Live Imaging Module Windows OS User Manual CONTENTS (Linked) Introduction 05 Menus, bars and tools 06 Title bar 06 Menu bar 06 Status bar 07 FPS 07

More information

User s Guide to the SPOT Cooled Color Digital Camera

User s Guide to the SPOT Cooled Color Digital Camera User s Guide to the SPOT Cooled Color Digital Camera Table of Contents: Copyright Information...2 Introduction/Document Conventions...3 Ch. 1 - Electronic Imaging Theory and the SPOT Camera...4 Ch. 2 -

More information

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s LSM 5 MP, LSM 510 and LSM 510 META M i c r o s c o p y f r o m C a r l Z e i s s Quick Guide Laser Scanning Microscopes LSM Software ZEN 2007 August 2007 We make it visible. Contents Page Contents... 1

More information

32 Float v3 Quick Start Guide. AUTHORED BY ANTHONY HERNANDEZ (415)

32 Float v3 Quick Start Guide. AUTHORED BY ANTHONY HERNANDEZ (415) 32 Float v3 Quick Start Guide 32 Float v3 Trademark/Copyright Information Copyright 2013 by United Color Technologies, LLC. All rights reserved. Unified Color Technologies, BeyondRGB, and HDR Expose are

More information

imsrc: converting a standard automated microscope into an intelligent screening platform

imsrc: converting a standard automated microscope into an intelligent screening platform Supplementary Information to: imsrc: converting a standard automated microscope into an intelligent screening platform Angel Carro 1, Manuel Perez-Martinez 2, Joaquim Soriano 2, David G. Pisano 1, Diego

More information

Quick Operation Guide

Quick Operation Guide Quick Operation Guide Power ON Mounting specimens Set the specimen on the sample holder, and install the sample holder to the holder frame. Attach the holder frame to the XY stage. Type of holder Main

More information

Windows INSTRUCTION MANUAL

Windows INSTRUCTION MANUAL Windows E INSTRUCTION MANUAL Contents About This Manual... 3 Main Features and Structure... 4 Operation Flow... 5 System Requirements... 8 Supported Image Formats... 8 1 Installing the Software... 1-1

More information

Locating Molecules Using GSD Technology Project Folders: Organization of Experiment Files...1

Locating Molecules Using GSD Technology Project Folders: Organization of Experiment Files...1 .....................................1 1 Project Folders: Organization of Experiment Files.................................1 2 Steps........................................................................2

More information

Protocols. Graphical programming for Icy. a.k.a. programming, for the rest of us

Protocols. Graphical programming for Icy. a.k.a. programming, for the rest of us Protocols Graphical programming for Icy a.k.a. programming, for the rest of us Foreword: Reproducible Research Quote: "Results aren't much if they can t be reproduced!" (your boss, your reviewers, your

More information

MetaXpress Software: Cell Scoring Module

MetaXpress Software: Cell Scoring Module MetaXpress Software: Cell Scoring Module Cell Scoring Module Overview The Cell Scoring module can be used to analyze cells imaged in 2 wavelengths W1 should be a stain for all nuclei (e.g. DAPI, Hoechst,

More information

Training Guide for Carl Zeiss AxioZoom V16 Stereo Microscope

Training Guide for Carl Zeiss AxioZoom V16 Stereo Microscope Training Guide for Carl Zeiss AxioZoom V16 Stereo Microscope ZEN 2012 Optical Imaging & Vital Microscopy Core Baylor College of Medicine (2017) Power ON Routine 1 2 If you require fluorescence imaging,

More information

Chlorophyll Fluorescence Imaging System

Chlorophyll Fluorescence Imaging System Quick Start Guide Chlorophyll Fluorescence Imaging System Quick Start Guide for Technologica FluorImager software for use with Technlogica CFImager hardware Copyright 2006 2015 TECHNOLOGICA LIMITED. All

More information

Release Highlights for BluePrint-PCB Product Version 2.0.1

Release Highlights for BluePrint-PCB Product Version 2.0.1 Release Highlights for BluePrint-PCB Product Version 2.0.1 Introduction BluePrint Version 2.0.1 is a rolling release for BluePrint V2.0. BluePrint rolling releases are delivered as needed and allow us

More information

Color and More. Color basics

Color and More. Color basics Color and More In this lesson, you'll evaluate an image in terms of its overall tonal range (lightness, darkness, and contrast), its overall balance of color, and its overall appearance for areas that

More information

ImageJ: Introduction to Image Analysis 3 May 2012 Jacqui Ross

ImageJ: Introduction to Image Analysis 3 May 2012 Jacqui Ross Biomedical Imaging Research Unit School of Medical Sciences Faculty of Medical and Health Sciences The University of Auckland Private Bag 92019 Auckland 1142, NZ Ph: 373 7599 ext. 87438 http://www.fmhs.auckland.ac.nz/sms/biru/.

More information

SolidWorks 95 User s Guide

SolidWorks 95 User s Guide SolidWorks 95 User s Guide Disclaimer: The following User Guide was extracted from SolidWorks 95 Help files and was not originally distributed in this format. All content 1995, SolidWorks Corporation Contents

More information

Microscopy from Carl Zeiss

Microscopy from Carl Zeiss Microscopy from Carl Zeiss Contents Page Contents... 1 Introduction... 1 Starting the System... 2 Introduction to ZEN Efficient Navigation... 5 Setting up the microscope... 10 Configuring the beam path

More information

4. Measuring Area in Digital Images

4. Measuring Area in Digital Images Chapter 4 4. Measuring Area in Digital Images There are three ways to measure the area of objects in digital images using tools in the AnalyzingDigitalImages software: Rectangle tool, Polygon tool, and

More information

LEICA TCS SP5 AOBS TANDEM USER MANUAL

LEICA TCS SP5 AOBS TANDEM USER MANUAL LEICA TCS SP5 AOBS TANDEM USER MANUAL STARTING THE SYSTEM...2 THE LAS AF SOFTWARE...3 THE «ACQUIRE» MENU...5 CHOOSE AND CREATE A SETTING...6 THE CONTROL PANEL...8 THE DMI6000B MICROSCOPE...10 ACQUIRE ONE

More information

Adding Objects Creating Shapes Adding. Getting Started Creating a Workspace Pages, Masters and Guides Adding Objects Creating Shapes Adding

Adding Objects Creating Shapes Adding. Getting Started Creating a Workspace Pages, Masters and Guides Adding Objects Creating Shapes Adding and Guides ILLUSTRATOR Adding Objects Creating Shapes Adding Getting Started WORKSHOP: Creating a Workspace Pages, Masters Workspace Pages, ADVANCED Masters and Guides Adding Objects WORKSHOP OBJECTIVES

More information

personal DELTAVISION (pdv)

personal DELTAVISION (pdv) GUIDELINES AND HINTS Version 1.3 (March 2015) personal DELTAVISION (pdv) Epifluorescence microscope from Applied Precision Inc.: The microscope can be found in room 1.320. For details see the architectural

More information

Adobe Studio on Adobe Photoshop CS2 Enhance scientific and medical images. 2 Hide the original layer.

Adobe Studio on Adobe Photoshop CS2 Enhance scientific and medical images. 2 Hide the original layer. 1 Adobe Studio on Adobe Photoshop CS2 Light, shadow and detail interact in wild and mysterious ways in microscopic photography, posing special challenges for the researcher and educator. With Adobe Photoshop

More information

Leica SP8 TCS Users Manual

Leica SP8 TCS Users Manual Version : 07/08/0 Leica SP8 TCS Users Manual Start up:. Turn the PC Microscope, Scanner Power, Laser Power, and the Laser Emission key to on (bottom right of desk).. Turn on the fluorescent lamp (top left

More information

Using the TWAIN Datasource

Using the TWAIN Datasource Using the TWAIN Datasource Starting the Scan Validation Tool... 2 The Scan Validation Tool dialog box... 3 Using the TWAIN Datasource... 5 How do I begin?... 5 Changing or creating a Setting Shortcut...

More information

μscope Microscopy Software

μscope Microscopy Software μscope Microscopy Software Pixelink μscope Essentials (ES) Software is an easy-to-use robust image capture tool optimized for productivity. Pixelink μscope Standard (SE) Software had added features, making

More information

Scan slides (Axon Genepix 4200AL)

Scan slides (Axon Genepix 4200AL) Page 1 Scan slides (Axon Genepix 4200AL) We need to scan the slides on both channels (Cy3 and Cy5) to obtain a 16-bit grayscale TIFF file for each. Typically these files are about 20-26Mb per channel,

More information

GXCapture 8.1 Instruction Manual

GXCapture 8.1 Instruction Manual GT Vision image acquisition, managing and processing software GXCapture 8.1 Instruction Manual Contents of the Instruction Manual GXC is the shortened name used for GXCapture Square brackets are used to

More information

ISCapture User Guide. advanced CCD imaging. Opticstar

ISCapture User Guide. advanced CCD imaging. Opticstar advanced CCD imaging Opticstar I We always check the accuracy of the information in our promotional material. However, due to the continuous process of product development and improvement it is possible

More information

Olympus xcellence Software - basic user guide

Olympus xcellence Software - basic user guide Olympus xcellence Software - basic user guide This is a basic overview of setting up time lapse experiments using Olympus's xcellence software on BIU's IX81 inverted phase contrast system - the software

More information

Automated Terrestrial EMI Emitter Detection, Classification, and Localization 1

Automated Terrestrial EMI Emitter Detection, Classification, and Localization 1 Automated Terrestrial EMI Emitter Detection, Classification, and Localization 1 Richard Stottler James Ong Chris Gioia Stottler Henke Associates, Inc., San Mateo, CA 94402 Chris Bowman, PhD Data Fusion

More information

Creating a 2D Drawing in Paper Space

Creating a 2D Drawing in Paper Space C h a p t e r 16 Creating a 2D Drawing in Paper Space In this chapter, we will learn the following to World Class standards: 1. Converting 3D Solids to 2D Orthographic Views 2. Open the Solid Part Drawing

More information

CAD Orientation (Mechanical and Architectural CAD)

CAD Orientation (Mechanical and Architectural CAD) Design and Drafting Description This is an introductory computer aided design (CAD) activity designed to give students the foundational skills required to complete future lessons. Students will learn all

More information

Using the Nikon TE2000 Inverted Microscope

Using the Nikon TE2000 Inverted Microscope Wellcome Trust Centre for Human Genetics Molecular Cytogenetics and Microscopy Core Using the Nikon TE2000 Inverted Microscope Fluorescence image acquisition using Scanalytic s IPLab software and the B&W

More information

The operation manual of spotlight 300 IR microscope

The operation manual of spotlight 300 IR microscope The operation manual of spotlight 300 IR microscope Make sure there is no sample under the microscope and then click spotlight on the desktop to open the software. You can do imaging with the image mode

More information

ID Photo Processor. Batch photo processing. User Guide

ID Photo Processor. Batch photo processing. User Guide ID Photo Processor Batch photo processing User Guide 2015 Akond company 197342, Russia, St.-Petersburg, Serdobolskaya, 65a Phone/fax: +7(812)384-6430 Cell: +7(921)757-8319 e-mail: info@akond.net http://www.akond.net

More information

ScanPotter. Reference Manual

ScanPotter. Reference Manual ScanPotter Reference Manual Copyright 2014 by Microtek International, Inc. All rights reserved. Trademarks Microtek, ScanMaker, ArtixScan, ScanWizard, ScanPotter and ColoRescue are trademarks or registered

More information

This week we will work with your Landsat images and classify them using supervised classification.

This week we will work with your Landsat images and classify them using supervised classification. GEPL 4500/5500 Lab 4: Supervised Classification: Part I: Selecting Training Sets Due: 4/6/04 This week we will work with your Landsat images and classify them using supervised classification. There are

More information

Version 2 Image Clarification Tool for Avid Editing Systems. Part of the dtective suite of forensic video analysis tools from Ocean Systems

Version 2 Image Clarification Tool for Avid Editing Systems. Part of the dtective suite of forensic video analysis tools from Ocean Systems By Version 2 Image Clarification Tool for Avid Editing Systems Part of the dtective suite of forensic video analysis tools from Ocean Systems User Guide www.oceansystems.com www.dtectivesystem.com Page

More information

Products - Microarray Scanners - Laser Scanners - InnoScan 900 Series and MAPIX Software

Products - Microarray Scanners - Laser Scanners - InnoScan 900 Series and MAPIX Software Products - Microarray Scanners - Laser Scanners - InnoScan 900 Series and MAPIX Software Arrayit offers the world s only next generation microarray scanning technology, with proprietary rotary motion control,

More information

Surface Analyzer TiVi95 User Manual. User Manual 3.1 Version 3.1 January 2012 PIONEERS IN TISSUE VIABILITY IMAGING

Surface Analyzer TiVi95 User Manual. User Manual 3.1 Version 3.1 January 2012 PIONEERS IN TISSUE VIABILITY IMAGING Surface Analyzer TiVi95 User Manual User Manual 3.1 Version 3.1 January 2012 PIONEERS IN TISSUE VIABILITY IMAGING Dear Valued Customer! Welcome to the WheelsBridge TiVi95 Skin Surface Analyzer system intended

More information

Scanning Setup Guide for TWAIN Datasource

Scanning Setup Guide for TWAIN Datasource Scanning Setup Guide for TWAIN Datasource Starting the Scan Validation Tool... 2 The Scan Validation Tool dialog box... 3 Using the TWAIN Datasource... 4 How do I begin?... 5 Selecting Image settings...

More information