UPK Series - Precision Integrating Spheres with Synthetic ODM98 Coating
|
|
- Reginald Butler
- 5 years ago
- Views:
Transcription
1 1 UPK Series - Precision Integrating Spheres with Synthetic Coating In cases where a high precision spherical form and precise alignment of sphere ports is critical, machined integrating spheres are a better choice than spheres formed out of aluminum sheets. In particular if precise port alignment is a requirement as in all kinds of transmittance, reflectance and absorbance measurements precise machined integrating spheres should be considered. In smaller diameter spheres the diffuse reflection of the sphere coating is important to produce a uniform light distribution inside the sphere. Our synthetic OD- M98 coating offers almost perfect diffuse reflection. Stock Model UPK-50-F for Reflection and Transmission Measurement Applications. Two different port arrangements are offered: UPK L type spheres are designed for the measurement of directional emitting light sources. A knife-edge measurement port opening offers a large acceptance angle for diverging light sources. Special baffle designs prevent any direct or first reflection illumination of the detector. UKP F type spheres are designed for flexible use in measurement of reflectance (8 /D), transmittance and power. The knife-edge design of the measurement port ensures that any diffuse reflected or transmitted light enters the sphere. The back side ports allow 8 sample illumination. To measure diffuse reflection, the -8 port can be opened so that directional glow radiation can pass out. Light traps are offered to absorb the light output of the 8 port. The back-side central port permits the separation of diffuse and directional transmitted light. An additional substitution port may help to reduce the substitution error during calibration and measurement. The back-side and substitution ports are supplied with coated port plugs. Custom Design Spheres Besides stock models, Gigahertz-Optik offers custom design modification, custom labeling and complete new product development service. Please contact the factory to discuss your requirements. Custom Design Precision Integrating Sphere with 254mm / 10 in Diameter and synthetic Coating. Eight Light Source Ports with Nikon Bayonet Mount.
2 2 1 0,9 0,8 0,7 e c 0,6 n ta c0,5 fle e R0,4 0,3 0,2 0, Wavelength [ nm ] Typical Spectral Reflectance of
3 3 UPK-30-L - Compact Size 30mm Diameter Integrating Sphere with Coating The UPK-30-L integrating sphere is Gigahertz-Optik s most compact size model with coating. The 30mm diameter integrating sphere with 5mm diameter measurement port offers high light throughput required in light sensitive applications within the spectral range from 250nm to 2500nm. Its unique collar baffle design greatly avoids direct illumination of the detector port from the light input port in a conventional 90 port position sphere design. The baffle also makes it possible to operate up to 4 detectors or fiber light guide connectors on the sphere at the same time. The UP-DP- 11 style detector ports provides an interface for direct mounting of Gigahertz-Optik s PD-11, TD-11 and VL- 11 type light detectors and UFC-11 type fiber connectors. Gigahertz-Optik s calibration laboratory offers traceable spectral radiant power sensitivity calibration in the wavelength range from 250nm to 1800nm. Stock Model Integrating Sphere UPK-30-L. Integrating Sphere UPK-30-L in Custom set-up with four InGaAs Detectors PD mm 5mm _UPK-30-L.pdf UPK-30-L mm integrating sphere. coating. One detector port.
4 4 UPK-30S60-L and UPK-30S60-TT - Stretch Integrating Sphere for Side Emitting Fibers Integrating sphere models UPK-30S60-L feature a unique stretched design specially made for the measurement of side emitting fibers up to 40mm long. Elongation of the coated sphere from 30mm diameter to a length of 60mm eliminates the need for a large diameter sphere. Its unique collar baffle design avoids direct illumination of the detector by the side emitting fiber. The detector port provides an interface for direct mounting of Gigahertz-Optik s PD-11, TD-11 and VL-11 type light detectors and UFC-11 type fiber light guide connectors. The recommended useful wavelength range of the stretched integrating sphere is from 250nm to 2500nm. Gigahertz-Optik s calibration laboratory offers traceable spectral radiant power sensitivity calibration in the wavelength range from 250nm to 1800nm. Stock Model Integrating Sphere UPK-30S60-L The model UPK-30S60-TT is equipped with a test tube guide that prevents the side emitting light guide from contacting the internal integrating sphere coating. The test tube can be removed for cleaning. Integrating Sphere UPK-30S60-TT 30mm x 60mm length Stainless steel adapter with 2mm hole _UPK-30S60-L.pdf _UPK-30S60-TT.pdf UPK-30S60-L x60mm stretched integrating sphere. coating. UPK-30S60-TT x60mm stretched integrating sphere with test tube. coating.
5 5 UPK-30S105-L - Stretch Integrating Sphere for Side Emitting Fibers The UPK-30S105-L model integrating sphere feature a unique stretched design specially made for the measurement of side emitting fibers up to 80mm long. Elongation of the coated sphere from 30mm diameter to a length of 105mm eliminates the need for a large diameter sphere. Its unique collar baffle design avoids direct illumination of the detector by the side emitting fiber. The detector port provides an interface for direct mounting of Gigahertz-Optik s PD-11, TD-11 and VL-11 type light detectors and UFC-11 type fiber connectors. The recommended useful wavelength range of the stretched integrating sphere is from 250nm to 2500nm. Gigahertz-Optik s calibration laboratory offers traceable spectral radiant power sensitivity calibration in the wavelength range from 250nm to 1800nm. Stock Model Integrating Sphere UPK-30S105-L 30x105mm Stainless steel adapter with 2mm hole _UPK-30S105-L.pdf UPK-30S105-L x105mm stretched integrating sphere. coating.
6 6 UPK-50-L - Compact Size 50mm Diameter Integrating Sphere with Coating The UPK-50-L integrating sphere is one of Gigahertz- Optik s compact size models with coating. The 50mm diameter integrating sphere with 10mm diameter measurement port offers high light throughput required in light sensitive applications within the spectral range from 250nm to 2500nm. Its unique collar baffle design greatly avoids direct illumination of the detector port from the light input port in a conventional 90 port position sphere design. The baffle also makes it possible to operate up to 4 detectors or fiber light guide connectors on the sphere at the same time. The detector ports provides an interface for direct mounting of Gigahertz-Optik s PD-11, TD-11 and VL- 11 type light detectors and UFC-11 type fiber connectors. Gigahertz-Optik s calibration laboratory offers traceable spectral radiant power sensitivity calibration in the wavelength range from 250nm to 1800nm. Stock Model Integrating Sphere UPK-50-L 50mm 10mm _UPK-50-L.pdf UPK-50-L mm integrating sphere. coating. One detector port.
7 7 UPK-50-F - 50mm Diameter Integrating Sphere for +8 /-8 Reflection The UPK-50-F integrating sphere with coating 1) is designed for universal use in light intensity, reflectance and transmittance measurement applications. The 50mm diameter integrating sphere with 10mm diameter measurement and two auxiliary ports in +/- 8 orientation to the measurement port offers high light throughput required in light sensitive applications within the spectral range from 250nm to 2500nm. Its unique collar baffle design greatly avoids direct illumination of the detector port from the light input port in a conventional 90 port position sphere design. The baffle also makes it possible to operate up to 4 detectors or fiber light guide connectors on the sphere at the same time. The detector ports provides an interface for direct mounting of Gigahertz-Optik s PD-11, TD-11 and VL-11 type light detectors and UFC-11 type fiber connectors. Gigahertz-Optik s calibration laboratory offers traceable spectral radiant power sensitivity calibration in the wavelength range from 250nm to 1800nm. Stock Model Integrating Sphere UPK-50-F 50mm 10mm +/- 8 Ports Diameter 10mm. Supplied with coated plugs _UPK-50-F.pdf UPK-50-F mm integrating sphere for reflection measurement. coating.
8 8 UPK-100-L - 100mm Diameter Integrating Sphere with Coating The UPK-100-L integrating sphere is one of Gigahertz -Optik s compact size models with coating 1). The 100mm diameter integrating sphere with 15mm diameter measurement port offers high light throughput required in light sensitive applications within the spectral range from 250nm to 2500nm. Its unique collar baffle design greatly avoids direct illumination of the detector port from the light input port in a conventional 90 port position sphere design. The baffle also makes it possible to operate up to 4 detectors or fiber light guide connectors on the sphere at the same time. The detector ports provides an interface for direct mounting of Gigahertz-Optik s PD-11, TD-11 and VL- 11 type light detectors and UFC-11 type fiber connectors. Gigahertz-Optik s calibration laboratory offers traceable spectral radiant power sensitivity calibration in the wavelength range from 250nm to 1800nm. Stock Model Integrating Sphere UPK-100-L 100mm 15mm _UPK-100-L.pdf UPK-100-L mm integrating sphere. coating. One detector port.
9 9 UPK-100-F - 100mm Diameter Integrating Sphere for 0 and +/-8 Reflection The UPK-100-F integrating sphere with coating 1) is designed for universal use in light intensity, reflectance and transmittance measurement applications. The 100mm diameter integrating sphere with 15mm diameter measurement and three auxiliary ports in +/- 8 and 0 orientation to the measurement port offers high light throughput required in light sensitive applications within the spectral range from 250nm to 2500nm. The auxiliary ports can be covered with coated port plugs when not in use. Its unique collar baffle design greatly avoids direct illumination of the detector port from the light input port in a conventional 90 port position sphere design. The baffle also makes it possible to operate up to 3 detectors or fiber light guide connectors on the sphere at the same time. The detector ports provides an interface for direct mounting of Gigahertz-Optik s PD-11, TD-11 and VL- 11 type light detectors and UFC-11 type fiber connectors. Gigahertz-Optik s calibration laboratory offers traceable spectral radiant power sensitivity calibration in the wavelength range from 250nm to 1800nm. Stock Model Integrating Sphere UPK-100-F 100mm 15mm 0 and +/- 8 Ports Diameter 10mm. Supplied with coated plugs _UPK-100-F.pdf UPK-100-F
10 10 UPK mm Integrating Sphere Body for Custom Design Set-up 150mm / 6 in diameter integrating spheres are the most commonly used size in measurement of light and measurement with light applications because of their good light throughput and sphere design criteria relationship. Sphere Body for Custom Design Solutions The UPK-150 integrating sphere with a diameter of 150mm with coating offers high light throughput in the spectral range from 250nm to 2500nm. This sphere is exclusively built to order offering complete freedom for individual custom design. Typical application set-ups are for an integrating sphere light source, light intensity detection, transmittance, reflectance and photoluminescence. UPK-150 Integrating Sphere in Custom Design for Absorbance Measurements UPK-150 Integrating Sphere in Custom Design for Photoluminescence Measurements 150mm 25mm _UPK-150.pdf _UPK-150.pdf in set-up for absorbance measurement _UPK-150.pdf in set-up for photoluminescence measurement UPK mm integrating sphere body for custom configuration.
11 11 UPK mm Integrating Sphere Body for Custom Design Set-up The UPK-190 integrating sphere with a diameter of 190mm with coating offers high light throughput in the spectral range from 250nm to 2500nm. This large diameter sphere is exclusively built to order offering complete freedom for individual custom design. Typical application set-ups are for an integrating sphere light source, light intensity detection, transmittance, reflectance and photoluminescence. Please contact the factory or a representative to discuss your sphere requirements. UPK-190 in Custom Design Set-up 190mm UPK mm integrating sphere body for custom configuration.
12 12 UPK mm Integrating Sphere Body for Custom Design Set-up The UPK-250 integrating sphere with a diameter of 254mm with coating offers high light throughput in the spectral range from 250nm to 2500nm. This large diameter sphere is exclusively built to order offering complete freedom for individual custom design. Typical application set-ups are for an integrating sphere light source, light intensity detection, transmittance, reflectance and photoluminescence. Please contact the factory or a representative to discuss your sphere requirements. UPK-250 in Custom Design Set-up 254mm UPK mm integrating sphere body for custom configuration.
13 An der Kälberweide 12 D Türkenfeld Telefon: +49 (0) Fax: +49 (0) Made in Germany
BTS2048-VL-CP-ILED-B-IS-1.0-HL
BTS2048-VL-CP-ILED-B-IS-1.0-HL https://www.gigahertz-optik.de/en-us/product/bts2048-vl-cp-iled-b-is-1.0-hl Product tags: VIS, NIR, Spectral Data, LED Binning, CIE 127, ILED-B, LED Gigahertz-Optik GmbH
More informationLED Tester BTS256-LED
1 LED Tester BTS256-LED The BTS256-LED tester is one of the most compact light measurement devices with integrated integrating sphere for high accuracy measurement of luminous flux, spectral and color
More informationISS-30-VA. Product tags: Integrating Sphere Source. https://www.gigahertz-optik.de/en-us/product/iss-30-va. Gigahertz-Optik GmbH 1/5
ISS-30-VA https://www.gigahertz-optik.de/en-us/product/iss-30-va Product tags: Integrating Sphere Source Gigahertz-Optik GmbH 1/5 Description standards for spectral radiance Spectroradiometers and other
More informationLED Tester BTS256-LED
1 LED Tester BTS256-LED The BTS256-LED tester is one of the most compact light measurement devices with integrated integrating sphere for high accuracy measurement of luminous flux, spectral and color
More informationIntegrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold
1354 MINIS Oriel Integrating Spheres Integrating spheres are ideal optical diffusers; they are used for radiometric measurements where uniform illumination or angular collection is essential, for reflectance
More informationPulsed Laser Power Measurement Systems
Pulsed Laser Power Measurement Systems Accurate, reproducible method of determining total laser and laser diode power Ideal for Beam Power Measurement Labsphere s Pulsed Laser Power Measurement Systems
More informationBTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.
BTS2048-BS http://www.gigahertz-optik.de/en-us/product/bts2048-bs Product tags: VIS, Spectral Data, Industrial Applications, Laser Gigahertz-Optik GmbH 1/6 Description BTS2048-BS CCD spectroradiometer
More informationFully Portable Spectrophotometer for Transmission Measurement
November 2008 LCRT-2005-S Portable Spectrophotometer for Transmission Measurement Spectral Transmission in d/0 and 0/0 Measurement Geometries Transparency Measurement in real in-line Set-up Photometric
More informationWe bring quality to light. MAS 40 Mini-Array Spectrometer
MAS 40 Mini-Array Spectrometer Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters Different models
More informationApplication Note (A16)
Application Note (A16) Eliminating LED Measurement Errors Revision: A December 2001 Gooch & Housego 4632 36 th Street, Orlando, FL 32811 Tel: 1 407 422 3171 Fax: 1 407 648 5412 Email: sales@goochandhousego.com
More informationTable of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...
LIGHT SOURCES Table of Content Fiber-Coupled s... 40 -Guide-Coupled s... 41 Collimator... 42 Low-cost Spot s... 43 Precision Spot s... 45 Spectrum Synthesizing ( Cubic S )... 46 Spectrometers 39 sources
More informationLED Lighting Flux and Color Measurement System (LFC)
LED Lighting Flux and Color Measurement System (LFC) Fast, accurate and complete System for research and production LFC System is a high cost efficiency light measurement system. The system is designed
More information1/8 m GRATING MONOCHROMATOR
1/8 m GRATING GRATING OUTPUT PORT INPUT PORT 77250 1/8 m Monochromator with 6025 Hg(Ar) Spectral Calibration Lamp. Low cost, compact size and high performance, ideal for OEM applications Very efficient
More informationTechnical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration
Technical Notes Integrating Sphere Measurement Part II: Calibration This Technical Note is Part II in a three part series examining the proper maintenance and use of integrating sphere light measurement
More informationOptical and Quantum Electronics (2005) 37: Ó Springer 2005 DOI /s
Optical and Quantum Electronics (2005) 37:529 543 Ó Springer 2005 DOI 10.1007/s11082-005-3955-5 Cryogenic radiometer based absolute spectral power responsivity calibration of integrating sphere radiometer
More informationLTE. Tester of laser range finders. Integrator Target slider. Transmitter channel. Receiver channel. Target slider Attenuator 2
a) b) External Attenuators Transmitter LRF Receiver Transmitter channel Receiver channel Integrator Target slider Target slider Attenuator 2 Attenuator 1 Detector Light source Pulse gene rator Fiber attenuator
More informationLI-193 Spherical Quantum Sensor
LI-193 Spherical Quantum Sensor The LI-193 Spherical Quantum Sensor measures PAR in air or underwater from all directions at depths up to 350 meters. This sensor is useful for studies of phytoplankton,
More informationBTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED. https://www.gigahertz-optik.de/en-us/product/bts2048-uv
BTS2048-UV https://www.gigahertz-optik.de/en-us/product/bts2048-uv Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED Gigahertz-Optik GmbH 1/8 Description UV CCD spectroradiometer
More informationTechnical Information OUSBT66
TI00469C/07/EN/02.13 71127776 Products Solutions Services Technical Information OUSBT66 Hygienic sensor for cell concentration measurement using NIR absorption Application Cell growth in bacterial fermentation
More informationLFV3-100SW LFV3-40SW. Transmittance rate (High) LED side. Move to LED side. LED side. Default position LFV3-CP-13RD. Wavelength/ color.
LFV series Refer to our website for product details. CCS LFV Use a search engine. Search You can also use your smartphone or cell phone. Provides diffused light evenly from LFV-RD LFV-SW LFV-BL -TP 2 H
More informationTechnological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter
1 BTS256-E Preliminary Datasheet Technological Advances in General Lighting The latest trends in general lighting involve replacing traditional light sources with SSL Solid State Lighting for energy savings,
More informationStarBright XLT Optical Coatings
StarBright XLT Optical Coatings StarBright XLT is Celestron s revolutionary optical coating system that outperforms any other coating in the commercial telescope market. Our most popular Schmidt-Cassegrain
More informationProduct tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting
MSC15 http://www.gigahertz-optik.de/en-us/product/msc15 Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting Gigahertz-Optik
More informationKeysight Technologies Optical Power Meter Head Special Calibrations. Brochure
Keysight Technologies Optical Power Meter Head Special Calibrations Brochure Introduction The test and measurement equipment you select and maintain in your production and qualification setups is one of
More informationCCT/10-13 MeP-K direct methods. Section 3.2: Absolute (spectral-band) radiometry (radiation thermometry)
CCT/10-13 MeP-K direct methods Section 3.2: Absolute (spectral-band) radiometry (radiation thermometry) Authors: Graham Machin (NPL, chair), Klaus Anhalt (PTB), Pieter Bloembergen (NIM, formerly NMIJ &
More informationChameleon Spectroradiometer
Chameleon Spectroradiometer SPEED / STABILITY / ACCURACY The Chameleon Series is designed to measure the absolute spectral of power, of the light under test. Adding optical probes and absolute calibration
More informationApplication Note (A11)
Application Note (A11) Slit and Aperture Selection in Spectroradiometry REVISION: C August 2013 Gooch & Housego 4632 36 th Street, Orlando, FL 32811 Tel: 1 407 422 3171 Fax: 1 407 648 5412 Email: sales@goochandhousego.com
More informationModel S471-LED Optometer
Model S471-LED Optometer For over 40 years UDT Instruments, a Gamma Scientific company, has been trusted by the world s leading organizations to provide accurate light measurement systems. UDT Instruments
More informationExternal Optical Probes. EOP-xxx and ISP 40. Two Global Leaders. One Complete Solution.
External Optical Probes EOP-xxx and ISP 40 Two Global Leaders. One Complete Solution. Our story Two Global Leaders. One Complete Solution. Konica Minolta Sensing Americas provides advanced optical technology
More informationLI-192 Underwater Quantum Sensor
LI-192 Underwater Quantum Sensor The LI-192 Underwater Quantum Sensor measures PAR from all angles in one hemisphere. The LI-192 works in air or underwater at depths up to 560 meters. The measurements
More informationSPECTRAL SCANNER. Recycling
SPECTRAL SCANNER The Spectral Scanner, produced on an original project of DV s.r.l., is an instrument to acquire with extreme simplicity the spectral distribution of the different wavelengths (spectral
More informationSpectroradiometer specbos 1201
Spectroradiometer specbos 1201 specbos 1201 is a precise and compact VIS spectroradiometer. It can be used in laboratory as well as production environment to measure the following quantities: Luminance,
More informationNEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET
REPLACE NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET 9925 Carroll Canyon Road San Diego, CA 92131 (800) 637-2758 (858) 279-8034 Fax (858) 576-9286 www.gamma-sci.com About Gamma Scientific:
More informationOL Series 426 Low Light Level lntegrating Sphere Calibration Standards
OL Series 426 Low Light Level lntegrating Sphere Calibration Standards GENERAL The OL Series 426 Low-Light-Level Calibration Standard is designed for accurately calibrating very sensitive microphotometers,
More informationLP PYRA 06. REV Jan. 2007
REV. 1.0 10 Jan. 2007 LP PYRA 06 Our instruments' quality level is the results of the product continuous development. This can bring about differences between the information written in this manual and
More informationDiamond Analysis. Innovation with Integrity. Reliable identification and type determination by FTIR spectroscopy FTIR
Diamond Analysis Reliable identification and type determination by FTIR spectroscopy Innovation with Integrity FTIR FTIR Diamond Analysis Since the appearance of synthetic diamonds, nearly perfect imitates
More information7110 MTF-FG 7110 MTF Measuring system Examples for complete measuring systems 7110 MTF or 7301 GWT with 7510 SAM-E Measuring system 7110 MTF or 7301 G
Technical Information TI 313e00 Solids Content Sensor 51508361 7510 SAM-T/E Solids Content Sensor for Average Concentrations using the Light Absorption Method The 7510 SAM sensor is used for optical solids
More informationAmer Technical Information TI 312e00 Solids Content Sensor SAH-T/E Solids Content Sensor for Average Concentrations Using the Light Abso
Technical Information TI 312e00 Solids Content Sensor 51508363 7510 SAH-T/E Solids Content Sensor for Average Concentrations Using the Light Absorption Method The 7510 sensor is used for optical solid
More informationUltraviolet Lights UV2 series
Lights -LA H 2 (5 types) Diffused Diffused Lights series Applications --365-N CCS For quick access. Lights that use high output -LEDs --365-W H2-24-365 --365-W LDL-138X12-365-N Detecting seal material
More informationPhotodiode Heads and Instruments
Photodiode Heads and Instruments The PD-300 series heads offer spectral coverage from 193-1800nm. The power range of the series is from picowatts to 3 Watts. 20 For latest updates please visit our website:
More informationThe Standard for over 40 Years
Light Measurement The Standard for over 40 Years Introduction LI-COR radiation sensors measure the flux of radiant energy the energy that drives plant growth, warms the earth, and lights our world. The
More informationINTERFEROMETER VI-direct
Universal Interferometers for Quality Control Ideal for Production and Quality Control INTERFEROMETER VI-direct Typical Applications Interferometers are an indispensable measurement tool for optical production
More informationINNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE
Image Engineering imagequalitytools INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE Image Engineering Relative Power ILLUMINATION DEVICES imagequalitytools The most flexible LED-based light
More informationBGS400 Lamp & Luminaire Goniophotometer (C-γ, B-ß Plane)
BGS400 Lamp & Luminaire Goniophotometer (C-γ, B-ß Plane) BGS400 Luminaire Goniophotometer (C-γ, B-ß Plane ) The BGS400 moving lamp and luminaire gonio-photometer is an economical, turnkey solution for
More informationZenith Polymer Diffuse Reflectance Standards, Targets and Materials. ... your Partner in Lighting Technology!
Zenith Polymer Diffuse Reflectance Standards, Targets and Materials For use over the UV, VIS and NIR spectral regions... your Partner in Lighting Technology! Properties of Zenith Polymer optical PTFE All
More informationLE7. user manual for the LE7 product line (x2, x4, x6, IR) 06 February 2018
user manual for the LE7 product line (x2, x4, x6, IR) 06 February 2018 Image Engineering GmbH & Co. KG. Im Gleisdreieck 5. 50169 Kerpen-Horrem. Germany T +49 2234 2273 99 99 1-0. F +49 2234 2273 99 99
More informationMS260i 1/4 M IMAGING SPECTROGRAPHS
MS260i 1/4 M IMAGING SPECTROGRAPHS ENTRANCE EXIT MS260i Spectrograph with 3 Track Fiber on input and InstaSpec IV CCD on output. Fig. 1 OPTICAL CONFIGURATION High resolution Up to three gratings, with
More informationApplications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region
Feature Article JY Division I nformation Optical Spectroscopy Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region Raymond Pini, Salvatore Atzeni Abstract Multichannel
More informationCHARA AO Calibration Process
CHARA AO Calibration Process Judit Sturmann CHARA AO Project Overview Phase I. Under way WFS on telescopes used as tip-tilt detector Phase II. Not yet funded WFS and large DM in place of M4 on telescopes
More informationPerformance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation
Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Rotation By: Michael Case and Roy Grayzel, Acton Research Corporation Introduction The majority of modern spectrographs and scanning
More informationFIBER EVO. Miniaturized laser module complete with controller and USB power supply all within an incredibly small package
Miniaturized laser module complete with controller and USB power supply all within an incredibly small package KEY FEATURES: Incredibly small yet fully featured Output powers up to 75 mw Powered by USB:
More informationspecification display & lighting hera spectrometer
specification display & lighting hera spectrometer Contents 1 Hera: cost effective spectrometer... 3 2 Highlights... 3 3 Speed & ease of use... 4 1 General specification Hera... 4 2 Hera series specifications...
More informationDescription of options, upgrades and accessories for the laser beam stabilization system Compact
Description of options, upgrades and accessories for the laser beam stabilization system Compact The basic configuration of the Compact laser beam stabilization system is fully equipped for stabilization
More informationCONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application
CONFIGURING Your Spectroscopy System For PEAK PERFORMANCE A guide to selecting the best Spectrometers, s, and s for your application Spectral Measurement System Spectral Measurement System Spectrograph
More informationTunable KiloArc. Tunable Broadband Light Source.
Optical Building Blocks Corporation Tunable KiloArc Tunable Broadband Light Source www.obb1.com Tunable KiloArc Need a CW laser that is tunable from 250 to 1,100 nm? yes Need it to deliver Hundreds of
More informationCoaxial Lights LFV3 series
Refer to our website for product details. CCS Use a search engine. Search You can also use your smartphone or cell phone. Provides diffused light evenly from the same axis as the camera -SW -SW -CP-18SW
More informationCompact High Intensity Light Source
Compact High Intensity Light Source General When a broadband light source in the ultraviolet-visible-near infrared portion of the spectrum is required, an arc lamp has no peer. The intensity of an arc
More informationHigh Power Laser Delivery Assemblies COPPER FERRULE PVC COVERED SST MONOCOIL. fiberguide ANODIZED ALUMINUM HEATSINK AIRGAP TECHNOLOGY - NO EPOXY
DESCRIPTION Multimode, step-index fibers offer a simple, efficient way to accurately deliver high power laser beams without the use of bulky, inconvenient and often heavy articulated arms. Much care has
More informationChapter 3 OPTICAL SOURCES AND DETECTORS
Chapter 3 OPTICAL SOURCES AND DETECTORS 3. Optical sources and Detectors 3.1 Introduction: The success of light wave communications and optical fiber sensors is due to the result of two technological breakthroughs.
More informationHigh Power Laser Delivery Assemblies COPPER FERRULE PVC COVERED SST MONOCOIL. fiberguide AIRGAP TECHNOLOGY - NO EPOXY
DESCRIPTION Multimode, step-index fibers offer a simple, efficient way to accurately deliver high power laser beams without the use of bulky, inconvenient and often heavy articulated arms. Much care has
More informationA-CUBE-Series High Sensitivity APD Detector Modules
Series Description Laser Components new A-CUBE range of APD modules has been designed for customers interested in experimenting with APDs. Featuring a low-noise silicon (or InGaAs) APD with matched preamplifier
More informationJETI Specbos Instruments
Spectral measuring instruments for various applications JETI Specbos Instruments The new Specbos family offers compact, spectrometric instruments, designed to measure the color coordinates, spectral characteristics
More informationLI-1500 Light Sensor Logger
LI-1500 Light Sensor Logger The LI-1500 Light Sensor Logger provides a direct digital readout and data logging from up to three LI-COR sensors at the same time. Log manually or set up one-time, daily,
More informationOP735. Benchtop Optical Power Meter Instruction Manual
Benchtop Optical Power Meter Instruction Manual www.optotest.com 1.805.987.1700 Contacting OptoTest Corporation 1.805.987.1700 (7:30 a.m. to 5 p.m. PST) www.optotest.com engineering@optotest.com OptoTest
More informationInstruction Manual MX-485-S Bi-directional RS485 Data Transceiver
Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver Copyright 2005, American Fibertek, Inc. 1020JD Table of Contents Functional Description...3 Installation...3 Power Source...3 Power Connection...3
More informationCIE 220:2016 Characterization and Calibration Method of UV Radiometers
CIE 220:2016 Characterization and Calibration Method of UV Radiometers Anton Gugg-Helminger Gigahertz-Optik GmbH, Germany www.gigahertz-optik.de Editor s note: This article has been reprinted from UV News,
More informationLGT Alignment Project Report, Using Fiber Optics as Light Sources for a BCAM
LGT Alignment Project Report, 4-26-2010 Using Fiber Optics as Light Sources for a BCAM Michael Collins, HEP Electronics Shop, Brandeis University. Overview Our design uses the LWDAQ to control modified
More informationInstruction Manual of Luminance and Spectral Radiance Calibrations
Aalto University School of Electrical Engineering Metrology Research Institute Jari Hovila Pasi Manninen Tuomas Poikonen Petri Kärhä Instruction Manual of Luminance and Version 2.6 07/12/2015 Page 2 (19)
More informationLEDGON 100. Goniophotometer. Two Global Leaders. One Complete Solution.
LEDGON 100 Goniophotometer Two Global Leaders. One Complete Solution. Our story Two Global Leaders. One Complete Solution. Konica Minolta Sensing Americas provides advanced optical technology that precisely
More informationHow-to guide. Working with a pre-assembled THz system
How-to guide 15/06/2016 1 Table of contents 0. Preparation / Basics...3 1. Input beam adjustment...4 2. Working with free space antennas...5 3. Working with fiber-coupled antennas...6 4. Contact details...8
More informationLEADING THE WAY in Light Measurement Systems
LEADING THE WAY in Light Measurement Systems LIGHT MEASUREMENT SYSTEMS THERMAL CONTROL SYSTEMS WIDE DYNAMIC RANGE SPECTROMETERS www.labsphere.com/illumia SOLUTION BASED PROFESSIONAL SOFTWARE Welcome to
More information\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä
\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä Ultraviolet Radiation from Some Types of Outdoor Lighting Lamps Dr.Essam El-Moghazy Photometry and Radiometry division, National Institute for Standards (NIS), Egypt.
More informationSPECTRORADIOMETRY METHODS: A GUIDE TO PHOTOMETRY AND VISIBLE SPECTRORADIOMETRY
SPECTRORADIOMETRY METHODS: A GUIDE TO PHOTOMETRY AND VISIBLE SPECTRORADIOMETRY Written By William E. Schneider, Richard Young, Ph.D 1. SPECTRORADIOMETRY METHODS 1.1. Spectroradiometrics vs Photometric
More informationVisioNIR. High Speed NIR Spectrometer for 100% Process Inspection
VisioNIR High Speed NIR Spectrometer for 100% Process Inspection Table of Content Introduction... 2 visiotec VisioNIR High Speed NIR Spectrometer: Your Way to PAT... 2 The benefits of the VisioNIR system...
More informationLIGHT READING - VCSEL TESTING
LIGHT READING - VCSEL TESTING Using the SemiProbe Probe System for Life (PS4L), vertical cavity surface emitting lasers (VCSELs) can be tested in a variety of formats including full wafer, diced die on
More informationOP710. Multichannel Optical Power Meter Instruction Manual. (Also supports the OP710-ANX)
Multichannel Optical Power Meter Instruction Manual (Also supports the OP710-ANX) www.optotest.com 1.805.987.1700 Contacting OptoTest Corporation 1.805.987.1700 (7:30 a.m. to 5 p.m. PST) www.optotest.com
More informationUnprecedented Resolution and Accuracy For Camera & Image Sensor Calibration
SpectralLED RS-7-1-VIS Benchtop Uniform Light Source For the ultimate in resolution and accuracy, the SpectralLED Tunable VIS source incorporates 35 discrete wavelengths for synthesis of commercially available
More informationThe CORONA Dryer and Blender
Spectral Sensors by Carl Zeiss The CORONA Dryer and Blender Product Information The CORONA Dryer and Blender System description The CORONA Dryer and Blender offers fast online measurements of the powder
More informationTOP 200. Telescopic Optical Probe for Radiance and Luminance Measurements. Two Global Leaders. One Complete Solution.
TOP 200 Telescopic Optical Probe for Radiance and Luminance Measurements Two Global Leaders. One Complete Solution. Our story Two Global Leaders. One Complete Solution. Konica Minolta Sensing Americas
More information1.9x3.9mm RECTANGULAR SOLID LAMP. Features. Description. Package Dimensions. Part Number: WP144GDT
1.9x3.9mm RECTANGULAR SOLID LAMP Part Number: WP144GDT Green Features Low power consumption. Reliable and rugged. Excellent uniformity of light output. Suitable for level indicator. Long life - solid state
More informationXENON FLASH LAMP MODULES
LAMP COMPACT W MODULES : L/L series (side-on type) : L/L series (head-on type) : L/L series (high output type) : L (SMA fiber adapter type) : L/L series (high precision type) : L/L series (silent type)
More informationArchitectural Door Accessories. Markar Continuous Hinges
Architectural Door Accessories Why Continuous Hinges? Hinge failure most commonly begins when doors are opened beyond stop device limits. The resulting kickback shock to the hinges can surpass 1000 lbs.
More informationAIXUV's Tools for EUV-Reflectometry Rainer Lebert, Christian Wies AIXUV GmbH, Steinbachstrasse 15, D Aachen, Germany
AIXUV's Tools for EUV-Reflectometry Rainer Lebert, Christian Wies, Steinbachstrasse 5, D-, Germany and partners developed several tools for EUV-reflectometry in different designs for various types of applications.
More informationORION ORION LASER POWER METER USER MANUAL. OPHIR OPTRONICS
ORION ORION LASER POWER METER USER MANUAL OPHIR OPTRONICS www.ophiropt.com/photonics Table of Contents Chapter 1 Introduction: How to Use This Manual... 2 Chapter 2 Quick Reference... 3 2.1 Getting Started...3
More informationImproving the Collection Efficiency of Raman Scattering
PERFORMANCE Unparalleled signal-to-noise ratio with diffraction-limited spectral and imaging resolution Deep-cooled CCD with excelon sensor technology Aberration-free optical design for uniform high resolution
More informationFiber Coupled Single Bar Diode Laser (CW)
Features High power, high brightness Small size, low weight Gaussian wavelength spectrum Additional function Applications Pumping IR Illumination Medical Industry manufacture Device Dimension (mm) (with
More informationDescription. Kingbright
1.6X0.8mm INFRARED EMITTING DIODE Part Number: KP-1608F3C Features 1.6mmX0.8mm SMT LED, 1.1mm thickness. Mechanically and spectrally matched to the phototransistor. Package: 2000pcs / reel. Moisture sensitivity
More informationKit for building your own THz Time-Domain Spectrometer
Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6
More informationLight emitting diode (LED) Lighting for Greenhouse Crops
Light emitting diode (LED) Lighting for Greenhouse Crops A.J. Both Associate Extension Specialist Dept. of Environmental Sciences both@aesop.rutgers.edu Electromagnetic radiation spectrum http://www.zulyzami.com
More informationic-sd85 olga SD2C3 Infrared LED
Rev C2, Page 1/6 FEATURES Emission peak at 850 nm matched to silicon sensors Broad irradiance pattern (lambertian profile) High temperature range -40 to 125 C High optical output power Fast switching speed
More informationEXPERIMENT 3 THE PHOTOELECTRIC EFFECT
EXPERIMENT 3 THE PHOTOELECTRIC EFFECT Equipment List Included Equipment 1. Mercury Light Source Enclosure 2. Track, 60 cm 3. Photodiode Enclosure 4. Mercury Light Source Power Supply 5. DC Current Amplifier
More informationIESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014
IESNA LM-79: 2008 Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE Dec 08, 2014 Product Name: LED Model No: 82031 Test Engineer: David Zhang Report No.: BTR66.181.14.0039.06
More informationic-sn85 BLCC SN1C INFRARED LED
Rev B3, Page 1/6 FEATURES Emission peak at 850 nm matched to silicon sensors Optimized irradiance pattern High temperature range -40 to 125 C High optical output power Fast switching speed APPLICATIONS
More informationAutomated Double Aperture Accessory
For the Cary 1, 3, 100, 300, 4, 5, 400, 500, 500i, 4000, 5000, 6000i, Deep UV Installation Category II Pollution Degree 2 Equipment Class I Table of Contents Introduction Theory Operation Installation
More informationIESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.
IESNA LM-79: 2008 Measurement and Test Report for Jiawei Technology (USA) Limited 2305 Lincoln Ave.Hayward, CA 94545 USA Apr 03, 2015 Product Name: self-ballast LED Lamp Model No: DL-9PAR30-830-LN-25-D;ML-9PAR30-830-LN-25-D
More informationPOWER MOLE SERIES DA KDDP3 MAYA
Technical Information With this stainless steel square product it is possible to create animated walls whether outdoors or indoors. You can illuminate your steps through its most indirect lighting... Table
More informationMicroscope-Spectrometer
20 Micro-spectrometer ToupTek s spectrometer is applicable for spectral detection within the wavelength range between 200nm and 1100nm. Due to their high stability and performance, these portable instruments
More informationINTERPLANT STANDARD - STEEL INDUSTRY
INTERPLANT STANDARD - STEEL INDUSTRY IPSS SPECIFICATION OF SENSOR MEASUREMENTS OF LENGTH OF ROLLED MATERIALS IPSS: 2-07-037-13 (First Revision) Corresponding Indian Standard does not exist Formerly-: IPSS:
More informationTest procedures Page: 1 of 5
Test procedures Page: 1 of 5 1 Scope This part of document establishes uniform requirements for measuring the numerical aperture of optical fibre, thereby assisting in the inspection of fibres and cables
More informationIESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR
IESNA LM-79: 2008 Measurement and Test Report for EiKO Global, LLC Sep 09, 2013 Product Name: LED Model No: LED8WMR16/38/830-DIM Test Engineer: David Zhang Report No.: BTR66.181.13.1294.01-1 Sample Received
More information