Photograph: Norith Eckbo
|
|
- Emory Stafford
- 5 years ago
- Views:
Transcription
1 Photograph: Norith Eckbo
2 Contaminants in Polar Regions PBDEs Particle deposition (high K OA ) HCHs High volatility: Single hoppers (high K AW ) Condensation DDT PCBs Evaporation Low volatility (low K AW ) Nonachlors Mirex chlordanes Multi-hoppers (grasshopper effect)
3 Arctic vs. Antarctic Predicted global distribution of total PCB 153 environmental burden (21) (Lammel and Stemmler. Atmos. Chem. Phys. 212)
4 Arctic vs. Antarctic Antarctic Circumpolar Current
5 Exposure risks to Antarctica? Increase industrial/agricultural activity in Southern Hemisphere E-waste dumping/ ship dismantling activities OC compounds detected in: air, soil, biota Contaminant monitoring needed to assess impacts of increased emission sources in Southern Hemisphere on Antarctic environment PAHs, PCBs, HCB
6 POLAR-ECOTOX project «To quantify temporal changes in contaminants to identify climatic, ecological, and anthropogenic drivers affecting exposure in Antarctic wildlife King penguin blood (2-217) Crozet Islands Photograph: Robin Cristofari Reside within and rely on the circumpolar current Provide a baseline to assess temporal changes in OC contaminant exposure
7 Challenges Sample material non-destructive sampling Limited material Low concentration levels Sample processing minimized to avoid analyte losses Photographs: Norith Eckbo
8 Sample preparation and analysis Liquid-liquid extraction 5% EtOH(NH 4 ) 2 SO 4 ):Hexane Automated SPE clean-up using activated Florosil Photograph: Norith Eckbo Photograph: Norith Eckbo Concentrated extract (5 µl) analyzed using GC-Orbitrap HRAM Full scan Targeted SIM
9 GC-Q-Exactive C-TRAP AQT Quadrupole Bent Flatapole HCD Cell 12K mass resolution FWHM (routine at 6K) Orbitrap Mass Analyzer ExtractaBrite Ion Source Resolving power useful to remove co-extracted matrix/chemical inteferences Detection sensitivity at ppt levels using full scan
10 PCB standard (7 pg/µl) RT: SM: 5G RT: PCB 28/ RT: Method details 1 µl injection (SSL injector, 25 C) Splitless time: 1.5 min Column: Thermo TG-5Sil MS Oven: 4 C (hold 1.5 min) 25 C/min -> 18 C 5 C/min -> 28 C 4 C/min -> 32 C (hold 5 min) Fullscan: 5-6 m/z, Res: 6K 6 4 PCB Congener RT: RT: Area 28/31 3.8e e e e e e e5 PCB 11 PCB RT: RT: PCB 153 PCB PCB 18 RT: 21.4
11 Pesticide standard RT: SM: 5G RT: RT: 1.2 HCB:1.3 pg/µl α-hch: 38 pg/µl RT: 1.9 β-hch: 1 pg/µl γ-hch: 26 pg/µl trans-chlordane: 1 pg/µl trans-nonachlor: 1 pg/µl RT: RT: RT: RT: p,p -DDE: 13 pg/µl p,p -DDT: 13 pg/µl Method details 1 µl injection (SSL injector, 25 C) Splitless time: 1.5 min Column: Thermo TG-5Sil MS Oven: 4 C (hold 1.5 min) 25 C/min -> 18 C 5 C/min -> 28 C 4 C/min -> 32 C (hold 5 min) Fullscan: 5-6 m/z, Res: 6K Mirex: 26 pg/µl Compound RT: Area HCB 4.8e5 α-hch 1.e7 β-hch 1.8e6 γ-hch 5.5e6 p,p -DDE 4.3e6 p,p -DDT 1.7e6 trans-chlordane 1.3e6 trans-nonachlor 1.4e6 Mirex 7.4e6
12 Antarctic penguin blood sample (full scan) RT: SM: 7B NL: 1.3e Indicates large matrix contribution to background signal
13 Antarctic penguin blood sample (PCBs) RT: SM: 7G RT: AA: RT: AA: 4497 PCB 28/31 PCB RT: MA: 137 PCB Method details 1 µl injection (SSL injector, 25 C) Splitless time: 1.5 min Column: Thermo TG-5Sil MS Oven: 4 C (hold 1.5 min) 25 C/min -> 18 C 5 C/min -> 28 C 4 C/min -> 32 C (hold 5 min) Fullscan: 5-6 m/z, Res: 6K PCB 28/31, 33, 66 and 153 detected PCB 153 RT: AA: Detection of target ions challenged due to competition within C-Trap with sample matrix and/or other chemical ions present at higher concentrations
14 Antarctic pengiun blood sample (pesticides) RT: SM: 5G RT: 1.33 AA: HCB Method details 1 µl injection (SSL injector, 25 C) Splitless time: 1.5 min Column: Thermo TG-5Sil MS Oven: 4 C (hold 1.5 min) 25 C/min -> 18 C 5 C/min -> 28 C 4 C/min -> 32 C (hold 5 min) Fullscan: 5-6 m/z, Res: 6K p,p -DDE RT: AA: HCB, ppdde and Mirex detected in full scan RT: AA: Mirex
15 Antarctic penguin blood sample T: FTMS p EI Full ms [5. 6.] p [ ] RT: SM: 7B C 5 H 11 = C 5 H 11 = mmu.1942 mmu C 7 H 13 = mmu min 15-2 min C 7 H 15 = mmu C 8 H 17 = mmu mmu min min C 18 H 27 = mmu C 7 H 15 = C 9 H 19 = mmu C 11 H 23 = mmu C 13 H 27 = mmu 2-28 min 2-28 min C 1 H 21 = C H 31 = C mmu 3 16 H 23 = mmu C 1 H 9 O 6 N 4 = mmu mmu C H 25 = C H 11 = mmu mmu C 4 O 13 N = C 14 H 29 = C mmu 19 H 9 O 3 N 5 = mmu mmu 1 1 C 28 H 9 N 6 = mmu 5 C H 9 O 6 N 4 = C 17 H 3 O 4 N 5 = C 28 H 9 NC 6 28 = H 9 N 6 = C mmu 19 H 9 O 3 N 5 = C 1 HC 19 O 14 N 1 = mmu mmu.1264 mmu.1889 mmu 1 H 19 O 14 N = C 1 H 19 O 14 N 1 = mmu mmu mmu m/z m/z 24.5 m/z
16 Full scan vs. reduced full scan RT: SM: 7B Scan:5-6 m/z NL: 1.3e RT: SM: 7B Scan:17-6 m/z NL: 9.2e8 NL: 9.17E8 TIC MS 217_81 _8_ Time 5(min)
17 Antarctic penguin blood sample (PCBs, 17-6 mz) RT: SM: 7G RT: AA: RT: AA: 3274 PCB 28/31 PCB RT: AA: RT: AA: PCB 37 PCB 52 PCB 47 PCB 66 RT: AA: 1437 RT: AA: PCB 11 RT: AA: PCB 99 RT: AA: RT: AA: PCB 149 RT: 17.5 AA: 8494 Higher detection frequency of PCBs with reduced scan range Congeners (orange) not detected in scan 5-6 mz PCB Removed mass regions of non-interest Maintained mass spectral data for identification of unknowns RT: AA: PCB PCB 153? PCB 187 RT: AA: PCB 18 RT: AA:
18 Full scan vs. reduced full scan RT: SM: 7B Scan:5-6 m/z NL: 1.3e RT: SM: 7B Scan:17-6 m/z NL: 9.2e8 NL: 9.17E8 TIC MS 217_81 _8_ Time 5 (min) Large matrix co-elution
19 Antarctic penguin blood sample (pesticides, 17-6 mz) RT: SM: 5G RT: 1.33 AA: RT: 1.21 AA: 1379 HCB RT: 1.91 AA: 2295 HCHs RT: AA: p,p -DDE Pesticide detection frequency also increased with reduced scan range HCHs* trans-chlordane trans-nonachlor RT: AA: trans-chlordane RT: AA: trans-nonachlor Mirex RT: AA:
20 Antarctic penguin blood sample (Targeted SIM (TSIM)) RT: SM: 7B When significant background 9.2e8 matrix present, 25 C/min TSIM -> 18 C is recommended for targeted analysis Scan:17-6 m/z RT: SM: 7B NL: Method details 1 µl injection (SSL injector, 25 C) Splitless time: 1.5 min NL: Column: Thermo TG-5Sil MS 9.17E8 TIC MS 217_81 _8_181 Oven: 4 C (hold 1.5 min) 5 C/min -> 28 C 4 C/min -> 32 C (hold 5 min) Targeted SIM: 8 m/z scan window, Resolution: 6K Targeted SIM NL: 1.48E7 TIC MS 218_123 NL: _7 1.5e
21 Antarctic penguin blood sample (PCBs, Targeted SIM) RT: SM: 7G RT: AA: RT: AA: RT: MA: RT: MA: 254 PCB RT: AA: RT: MA: RT: 16.3 MA: RT: AA: 2986 RT: MA: 1184 RT: AA: PCB 153 RT: AA: 87 Similar findings to reduced full scan PCB 15 RT: AA: PCB 153 detected in TSIM by removing matrix co-elution Additional congeners detected (71, 15, 183) Better peak shape RT: AA: PCB 183 RT: 2.3 AA: 237 RT: AA:
22 Peak shape comparison RT: SM: 5G MA: Reduced full scan: 17-6 mz MA: PCB MA: PCB PCB 187 MA: 412 MA: 581 RT: SM: 5G AA: PCB 153 Targeted SIM MA: 6414 PCB PCB 187 AA: 1862 PCB 183 AA: 129 PCB 18 AA:
23 Antarctic penguin blood sample (pesticides, Targeted SIM) RT: SM: 5G RT: 1.73 AA: RT: 11.9 AA: 137 RT: AA: 4795 RT: 16.9 AA: Similar findings as observed with PCBs Additional pesticides detected DDD, DDT, cis-chlordane, cis-nonachlor RT: AA: RT: AA: 457 p,p -DDD RT: MA: 1587 RT: AA: cis-chlordane p,p -DDT 1 5 RT: MA: cis-nonachor RT: AA: RT: AA:
24 Simultaneous full scan and targeted SIM Full scan acquisition at 6K mass resolution Targeted SIM acquisition at 3K mass resolution Can obtain targeted analysis specificity without loss of full scan mass spectral data for identification of unknown compounds
25 Antarctic penguin blood (Target SIM/Full scan) RT: SM: 7B Scan: 5-6 m/z RT: SM: 7G RT: AA: RT: AA: 6673 PCB 28/31 PCB 33 RT: MA: 1965 PCB 52 PCB 47 PCB 66 RT: 13.7 MA: RT: 15.3 MA: RT: MA: 594 PCB 11 PCB 99 RT: MA: RT: AA: 7658 PCB 118 RT: AA: 141 PCB 15 1 RT: AA: 6186 RT: AA: 4314 PCB 153 PCB PCB 149 RT: AA: 1414 PCB 187 RT: AA: 649 PCB 18 RT: AA:
26 Antarctic penguin blood (Target SIM/Full scan) RT: SM: 7G RT: 1.7 AA: HCB p,p - DDE RT: AA: RT: SM: 7B Scan: 5-6 m/z trans-chlordane RT: AA: trans-nonachlor RT: MA: 4425 RT: 18.2 AA: 2668 cis-nonachlor 1 5 Mirex RT: AA:
27 OC concentrations in penguin blood sample PCB congener Concentration (pg/g ww) Pesticide Concentration (pg/g ww) HCB 29 ahch 3.9 p,p -DDT 1.38 p,p -DDD 4.72 p,p -DDE 11 trans-chlordane 11.7 cis-chlordane 3.5 trans-nonachlor 11.7 cis-nonachlor.9 Mirex 38 Blank subtraction performed on sample results LOQ: pg/g ww (compound dependent)
28 GC-Q-Exactive provides excellent sensitivity for OC analysis in penguin blood Sample matrix can hinder detection at ppt concentrations PCBs and OC pesticides detected at ppt concentrations in full scan and TSIM Targeted SIM can reduce influence of matrix ions in C-Trap HCB, ppdde, Mirex dominate in penguin blood Full scan data acquired simultaneously without compromising targeted analysis Photograph: Norith Eckbo
29
30 Acknowledgements Cristian Cojocariu (Thermo Scientific) Strategic Institute Funding grant (CleanArctic, NRC) POLAR-ECOTOX project (NRC) Photograph: Norith Eckbo
Profiling of Volatile Organic Compounds in Milk and Orange Juice Using Headspace Analysis
Profiling of Volatile Organic Compounds in Milk and Orange Juice Using Headspace Analysis HT3 Application Note Introduction Volatile organic compounds, VOCs, present in liquid food products play a very
More informationApproaches to highest sensitivity analysis of selected Dioxin / Furan congeners:
Approaches to highest sensitivity analysis of selected Dioxin / Furan congeners: a.) Cryogenic Peak Zone Focusing (cyro - PZF) b.) Fast GC Dirk Krumwiede, Jeff Focant, Heinz Mehlmann, Daniela Cavagnino,
More informationQUANTOF. High-resolution, accurate mass, quantitative time-of-flight MS technology
QUANTOF High-resolution, accurate mass, quantitative time-of-flight MS technology Orthogonal-acceleration time-of-flight (oatof) mass spectrometers are invaluable tools for the detection and identification
More informationThermo Scientific DFS
Thermo Scientific DFS High Resolution Sector Field MS Instrument performance standards for Dioxin / Furan analysis Dirk Krumwiede, Product Specialist Trace MS Overview: presentation main topics 1.) NEW
More informationDetermination of the N-Nitrosamine Content in Rubber Articles Using the Agilent 7000A Triple Quadrupole GC/MS System
Determination of the N-Nitrosamine Content in Rubber Articles Using the Agilent 7A Triple Quadrupole GC/MS System Application Note Consumer Products Authors Yun Zou and Chongtian Yu Agilent Technologies
More informationA new gold standard for Dioxin analysis A combined approach ; automated efficient clean-up together with a new Triple Quadrupole GC-MS/MS
A new gold standard for Dioxin analysis A combined approach ; automated efficient clean-up together with a new Triple Quadrupole GC-MS/MS Haruhiko Miyagawa, GCMS Product Manager Analytical &Measuring Instruments
More informationPrep TM Automated Extraction and Clean-up System for PCDDs, PCDFs and PCBs
Power-Prep Prep TM Automated Extraction and Clean-up System for PCDDs, PCDFs and PCBs Jef Focant and Hamid Shirkhan Dioxin Lab. BELGIUM FMS Inc. WWW.FMS-INC.Com USA Dioxins Analysis! Extraction (Soxhlet,
More information"What s inside your car?
"What s inside your car? Car interior emissions testing using Thermal desorption GC/MS analysis Inge de Dobbeleer EU GCMS specialist ThermoFisher Lara Kelly Sales Manager Markes Thermal desorption The
More informationRoger Bardsley, Applications Chemist; Teledyne Tekmar Page 1
Application Note Meeting the Korean Method ES 04607.1 for Naphthalene ( 나프탈렌 ) with Static and Dynamic Headspace GC/MS Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Introduction The Korean
More informationN-Methyl-1-(6-methylpyridin-2-yl)propan-2-amine
H C N CH HN CH. GENERAL INFORMATION IUPAC Name: CAS#: Not Available Synonyms: Source: Appearance: Not Available DEA Reference Material Collection Pale yellow powder UV max (nm): Not Determined. CHEMICAL
More informationAdvanced FTMS Data Acquisition and Processing
Advanced FTMS Data Acquisition and Processing FTMS Booster : New Generation Electronics Measures transients from any FTMS instrument Improves performance and productivity of FTMS instruments Enables advanced
More informationPersistant Organic Pollutants
Persistant Organic Pollutants Fast screening and precise confirmation with GC-MSMS and GC-HRMS. Hans-Joachim Huebschmann GC-MS Technology Manager Dirk Krumwiede Product & Application Specialist for Advanced
More informationA Survey of Residual Solvents in Various Inks used in Consumer Product Packaging
A Survey of Residual Solvents in Various Inks used in Consumer Product Packaging Application Note Abstract Food manufacturers use various printing inks on their consumer product packaging. These inks are
More informationIntroducing the Agilent 7000A Triple Quadrupole GC/MS
Introducing the Agilent 7000A Triple Quadrupole GC/MS Paul Zavitsanos, Joe Weitzel, Monty Benefiel and Terry Sheehan May 2008 Page 1 What s a Triple Quad? Page 2 GC/MS Triple Quad (QQQ) Collision Gas (N2
More informationFapas Food Chemistry Proficiency Test Report Pesticide Residues in Rice. June-August Page 1 of 38
Fapas Food Chemistry Proficiency Test Report 09110 Pesticide Residues in Rice N O T C O N TR O LL ED W H EN PR IN TE D June-August 2017 Page 1 of 38 PARTICIPANT LABORATORY NUMBER Participants can log in
More informationUltrasensitive LC MS/MS: Agilent 6470 and 6495 LC-QQQ
Ultrasensitive LC MS/MS: Agilent 6470 and 6495 LC-QQQ ROCK SOLID Performance for Trace-Level Quantitation Agilent Technologies 1 Brief History of Agilent 6400 QQQ LC/MS 6410 2006 6460 Agilent Jet Stream
More informationWelcome! Denver, CO Houston, TX February 2009
Welcome! Denver, CO Houston, TX February 2009 Schedule & Introductions Announcements - Safety - Evaluation forms - Upcoming events > CBMSS, Feb 10 th, Nat l Jewish Center, www.cbmss.org (also Apr 22 nd
More informationUseful GC/MS Sensitivity for Improved Environmental Analyses. Terry L. Sheehan, Ph.D. GC/MS Senior Product Manager Santa Clara, CA 7 February 2008
Useful GC/MS Sensitivity for Improved Environmental Analyses Terry L. Sheehan, Ph.D. GC/MS Senior Product Manager Santa Clara, CA 7 February 2008 Definitions Sensitivity Analytical definition: slope of
More informationMT-540. D-Ribavirin, [ 3 H]- Lot A DG
MT-54 D-Ribavirin, [ 3 H]- Lot 165-145-225-A-2835-DG A) All chromatograms were run using the HPLC method described on the Product Data Sheet. Concentrations and volumes: Standard solution concentration
More informationChem466 Lecture Notes. Spring, 2004
Chem466 Lecture Notes Spring, 004 Overview of the course: Many of you will use instruments for chemical analyses in lab. settings. Some of you will go into careers (medicine, pharmacology, forensic science,
More informationImproved Separation and Quantification of Dioxin and Furan Congeners Using an Application-Specific Capillary Gas Chromatographic Column and GC-HRMS
Improved Separation and Quantification of Dioxin and Furan Congeners Using an Application-Specific Capillary Gas Chromatographic Column and GC-HRMS Frank Dorman, Shawn Reese, Gary Stidsen Restek Corporation,
More informationMT Gemcitabine, [5-3 H(N)]- Lot A NK
MT-1572 Gemcitabine, [5-3 H(N)]- Lot 194-14-234-A-2514-NK A) All chromatograms were run using the HPLC method described on the Product Data Sheet. Concentrations and volumes: Standard solution concentration
More informationSCIEX Presentation. Name of Speaker, Identification. QTRAP Functionalities. Alexandre Paccou Name of Speaker, Identification. SCIEX Presentation.
SCIEX Presentation Alexandre Paccou Name of Speaker, Identification Date SCIEX Presentation QTRAP Functionalities Hardware and Software Tipps und Tricks, Name of Speaker, Identification Date For Research
More informationLC/MS/MS. Page Header. triple quadrupole mass spectrometer.
LC/MS/MS VARIAN, INC. 320-MS Page Header triple quadrupole mass spectrometer www.varianinc.com VARIAN, INC. 320-MS Unsurpassed commitment to innovation Varian, Inc. is an innovator and leader in mass spectrometry
More informationTechnicalNOTE EVALUATION OF LCT PREMIER NEGATIVE ION MODE ESI EXACT MASS MEASUREMENT PERFORMANCE. Introduction. Objective
Objective The aim of the study presented is to illustrate the enhanced performance of the Waters Micromass LCT Premier oa-tof Spectrometer. The data presented shows mass accuracy achieved over a twelve-hour
More informationAutomated Orthogonal Control System for Electrospray Ionization Mass Spectrometry
utomated Orthogonal Control System for Electrospray Ionization Mass Spectrometry Gary. Valaskovic 1, James P. Murphy III 1, Mike S. Lee 2 1 New Objective Inc, Woburn, M 2 Milestone Development Services,
More informationXcalibur. LCquan. Tutorial. Quantitative Analysis of a Three-Drugs Data Set Software Version 2.8
Xcalibur LCquan Tutorial Quantitative Analysis of a Three-Drugs Data Set Software Version 2.8 XCALI-97547 Revision A April 2013 2013 Thermo Fisher Scientific Inc. All rights reserved. LCquan, DCMS Link,
More informationA New Conjoined RF Ion Guide for Enhanced Ion Transmission
A New Conjoined RF Ion Guide for Enhanced Ion Transmission Kevin Giles and David Gordon Waters Corporation, Manchester, UK APPLICATION BENEFITS We describe a novel conjoined ion guide that operates at
More informationAdvantages of Multi-Turn-TOF Technology
Advantages of Multi-Turn-TOF Technology Ordinary TOF vs. Multi-Turn TOF Ordinary TOF) TOF-MS is one of the most popular technologies for high resolution applications, particularly in ESI and MALDI instruments.
More informationGC Application Note. Quantification of nitrosamines in water by automated PAL SPME-Arrow and GC/MS.
GC Application Note Quantification of nitrosamines in water by automated PAL SPME-Arrow and GC/MS www.palsystem.com Quantification of nitrosamines in water by automated PAL SPME-Arrow and GC/MS Peter Egli,
More informationFTMS Booster X1 High-performance data acquisition system for Orbitrap FTMS
FTMS Booster X1 High-performance data acquisition system for Orbitrap FTMS What is FTMS Booster? The Spectroswiss FTMS Booster X1 is a high-performance data acquisition and analysis system based on state-of-the-art
More informationNew fraction collection features with the Agilent 220 micro plate sampler and micro plate sampling software rev. A.03. Technical Note.
New fraction collection features with the Agilent 220 micro plate sampler and micro plate sampling software rev. A.03 Technical Note Introduction The Agilent 220 micro plate sampler (MPS) is an essential
More informationCollision cell: Fragmentation efficiency > 90 % Duty cycle: Variable between 1 and 50 % (user selectable trapping time/scan time ratio) Transmission:
Finnigan MAT 95 XP-API-GC-Trap tandem Mass spectrometer system Tandem Mass Spectrometer based on high resolution magnetic sector and Ion-Trap MS/MS system with API ( ESI, APCI ) and EI/CI ionization Mass
More informationOptimisation of LCMS Techniques for Complementary Medicines
Optimisation of LCMS Techniques for Complementary Medicines Ashley Dowell Southern Cross Plant Science Southern Cross University Complementary Medicines Complementary medicines vitas erals herbal medicines
More informationDoD ELAP and QSM 5.1 A Laboratory Perspective. Larry Penfold Quality Compliance Director
DoD ELAP and QSM 5.1 A Laboratory Perspective Larry Penfold Quality Compliance Director Discussion Topics Quality Systems Manual (QSM) V.5.1 released Jan. 2017 What it means for laboratory accreditations
More informationContaminants in Overwintering Canvasbacks (Aythya valisineria) and Resident Mallards (Anas platyrhynchos) in the Lake St. Clair/St.
Contaminants in Overwintering Canvasbacks (Aythya valisineria) and Resident Mallards (Anas platyrhynchos) in the Lake St. Clair/St. Clair River Area Environment Canada - Ecotoxicology and Wildlife Health
More informationIntegration and Optimization of Hardware and Software for a Differential Flow Modulated GCxGC
Paper 170-2 Integration and Optimization of Hardware and Software for a Differential Flow Modulated GCxGC Roger Firor, James McCurry, Chunxiao Wang and Michael Feeney Agilent Technologies Wilmington, DE
More informationDetection and Quantitation of Brominated and Chlorinated Hydrocarbons by DART with Linear Ion Trap and Triple Quadrupole Technology
Detection and Quantitation of Brominated and Chlorinated Hydrocarbons by DART with Linear Ion Trap and Triple Quadrupole Technology Mary L. Blackburn 1, Scott J. Harrison 2, and Maria C. Prieto Conaway
More informationDamage-free failure/defect analysis in electronics and semiconductor industries using micro-atr FTIR imaging
Damage-free failure/defect analysis in electronics and semiconductor industries using micro-atr FTIR imaging Application note Electronics and Semiconductor Authors Dr. Mustafa Kansiz and Dr. Kevin Grant
More informationExamining Comprehensive Flow-Modulated Two-Dimensional Gas Chromatography
Examining Comprehensive Flow-Modulated Two-Dimensional Gas Chromatography Roger L. Firor Senior Applications Chemist, Agilent Technologies roger_fi ror@agilent.com 1 Agilent Measurement Journal Gas chromatography
More informationProject Planning Considerations For Emerging Contaminants. Ed Corl NAVSEA LQAO
Project Planning Considerations For Emerging Contaminants Ed Corl NAVSEA LQAO Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection of information is estimated
More informationNon-Destructive Ion Trap Mass Analysis at High Pressure. Supporting information
Non-Destructive Ion Trap Mass Analysis at High Pressure Supporting information Wei Xu 1, Jeffrey Maas 2, Frank Boudreau 3, William J. Chappell 2 and Zheng Ouyang 1,2,3* 1. Weldon School of Biomedical Engineering,
More informationPerformance characteristics of a new wide range, fast settling electrometer design for a residual gas analysis mass spectrometer
Performance characteristics of a new wide range, fast settling electrometer design for a residual gas analysis mass spectrometer MKS Spectra Products, January 2010 Design considerations for RGA components
More informationOutcome of HELCOM HOLAS II Workshop on integrated hazardous substances assessment (HOLAS II HZ WS )
Baltic Marine Environment Protection Commission Project for the development of the second holistic assessment of the Baltic Sea HOLAS II Workshop on integrated hazardous substances assessment Helsinki,
More informationMinimizing purification time with high resolution flash chromatography
Minimizing purification time with high resolution flash chromatography David Trail*, Veronica Thomason, and John Urh Teledyne Isco Inc., P.O. Box 82531, Lincoln NE 68501 vthomason@teledyne.com (800) 228-4373
More informationTechnical Specifications for the procurement of Inductively Coupled Plasma Mass Spectrometer (ICP-MS)
Technical Specifications for the procurement of Inductively Coupled Plasma Mass Spectrometer (ICP-MS) Preamble An Inductively Coupled Plasma Mass Spectrometer (Quadrupole ICP-MS) is proposed to be procured
More informationVolatile methyl siloxanes
Volatile methyl siloxanes Carrier in antiperspirants/deodorants Shampoo, conditioners, cosmetics VC exempt cleaning solvents Estimated global emissions to the atmosphere of >30000 tonnes/yr not including
More informationPractical Quadrupole Theory: Graphical Theory
Extrel Application Note RA_21A Practical Quadrupole Theory: Graphical Theory Randall E. Pedder ABB Inc., Analytical-QMS Extrel Quadrupole Mass Spectrometry, 575 Epsilon Drive, Pittsburgh, PA 15238 (Poster
More informationTrends in chemical composition of global and regional population-weighted fine particulate matter over the recent 25 years
8th International GEOS-Chem Meeting Trends in chemical composition of global and regional population-weighted fine particulate matter over the recent 25 years Chi Li (chi.li@dal.ca), PhD Candidate Randall
More informationThe 5975C Series MSDs: Normalized Instrument Tuning. Technical Overview. Introduction
The 5975C Series MSDs: Normalized Instrument Tuning Technical Overview Jeffrey T. Kernan and Harry Prest Introduction The automated optimization of ion detection in a mass spectrometer, commonly referred
More informationProdigy DC Arc The Ultimate Solution for Elemental Analysis of Solid Samples
Prodigy DC Arc The Ultimate Solution for Elemental Analysis of Solid Samples ICP Spectrometers Hg Analyzers Hg Emission Monitoring Inorganic Standards Expect more The purchase of a new instrument is an
More information1. Charge deposition onto or into an ESI emitter, causes an immediate electrospray to occur called relay ElectroSpray Ionization(rESI) technique. 2.
Vishal 16-09-2017 1. Charge deposition onto or into an ESI emitter, causes an immediate electrospray to occur called relay ElectroSpray Ionization(rESI) technique. 2. The positive and negative ion currents
More informationSite-specific Bioaccumulation of PCDD/PCDFs in Mothers and their Infants Living in Vicinity of Bien Hoa Airbase, Southern Vietnam
4 th International Forum on Sustainable Future in Asia 4 th NIES International Forum Site-specific Bioaccumulation of PCDD/PCDFs in Mothers and their Infants Living in Vicinity of Bien Hoa Airbase, Southern
More informationHigh resolution ion mobility-mass spectrometry for separation and identification of isomeric lipids
Electronic Supplementary Material (ESI) for Analyst. This journal is The Royal Society of Chemistry 2015 High resolution ion mobility-mass spectrometry for separation and identification of isomeric lipids
More informationRedox-Innocent Metal-Assisted Cleavage of S-S. Bond in a Disulfide-Containing Ligand.
Supplementary Information for Redox-Innocent Metal-Assisted Cleavage of S-S Bond in a Disulfide-Containing Ligand. Charlène Esmieu, Maylis Orio, Laurent Le Pape, Colette Lebrun, Jacques Pécaut, Stéphane
More informationGUIDE TO SELECTING HYPERSPECTRAL INSTRUMENTS
GUIDE TO SELECTING HYPERSPECTRAL INSTRUMENTS Safe Non-contact Non-destructive Applicable to many biological, chemical and physical problems Hyperspectral imaging (HSI) is finally gaining the momentum that
More informationSubminiature Photoionization VOC Sensor Boris Dolgov, Baseline-MOCON, Inc.
Subminiature Photoionization VOC Sensor Boris Dolgov, Baseline-MOCON, Inc. Lyons, CO 80540, USA (303) 823-6661 boris.dolgov@baseline.cc 1 1. Objective Monitoring of Volatile Organic Compounds (VOCs) is
More informationUsing Event Trigger Panel for IE/AB and Transmission Curve Calibrations
Using Event Trigger Panel for IE/AB and Transmission Curve Calibrations Benjamin Nault + Jimenez Group AMS User s Meeting, Portland October 21st - 23rd, 2016 Take Away Points ET is a Powerful Tool for
More informationGas chromatograph Shimadzu GC-17A
Gas chromatograph Shimadzu GC-17A and UniChrom page 1 of 7 Contents General information...3 Communication board...3 ADC...3 Direct connection to the FID...4 GC-17A instrument configuration with ADC...4
More informationElectron Multipliers. Introduction to ETP Electron Multipliers Selection by Technique: LC-MS 242
Introduction to ETP 240-241 Selection by Technique: GC-MS 242 LC-MS 242 ICP-MS 242 TOF-MS 243 Magnetic Sector 243 Selection by Instrument 243-244 ETP are individually tested to ensure the highest quality.
More informationUCT SELECTRA C18 HPLC COLUMN INNOVATION THROUGH CHEMISTRY
UCT SELECTRA C18 HPLC COLUMN INNOVATION THROUGH CHEMISTRY SELECTRA C18 HPLC COLUMNS Benefits Good choice for easily converting current C18 methods Suitable for most traditional reverse phase analyses High
More informationToF-AMS DAQ. Joel Kimmel Univ. of Colorado at Boulder & Aerodyne Research, Inc AMS Users Meeting 2007
ToF-AMS DAQ Joel Kimmel Univ. of Colorado at Boulder & Aerodyne Research, Inc AMS Users Meeting 2007 1 Web Resources http://cires.colorado.edu/jimenez-group/tofamsresources/tofsoftware/ Downloads Release
More informationPRELIMINARY CHARACTERIZATION OF THE EMISSIONS FROM SCENTED TEA-LIGHT CANDLES
PRELIMINARY CHARACTERIZATION OF THE EMISSIONS FROM SCENTED TEA-LIGHT CANDLES E. Oddo, M. Derudi marco.derudi@polimi.it Politecnico di Milano, Dip. di Chimica, Materiali e Ingegneria Chimica G. Natta, Milano,
More informationMaterial analysis by infrared mapping: A case study using a multilayer
Material analysis by infrared mapping: A case study using a multilayer paint sample Application Note Author Dr. Jonah Kirkwood, Dr. John Wilson and Dr. Mustafa Kansiz Agilent Technologies, Inc. Introduction
More informationFTIR microscopy and imaging for failure analysis in electronics manufacturing
FTIR microscopy and imaging for failure analysis in electronics manufacturing Application Note Author Steven M. Barnett, Ellen V. Miseo, and Wayne Jalenak Agilent Technologies, Inc. Introduction The electronics
More informationEE4512 Analog and Digital Communications Chapter 6. Chapter 6 Analog Modulation and Demodulation
Chapter 6 Analog Modulation and Demodulation Chapter 6 Analog Modulation and Demodulation Amplitude Modulation Pages 306-309 309 The analytical signal for double sideband, large carrier amplitude modulation
More informationChemical Imaging. Whiskbroom Imaging. Staring Imaging. Pushbroom Imaging. Whiskbroom. Staring. Pushbroom
Chemical Imaging Whiskbroom Chemical Imaging (CI) combines different technologies like optical microscopy, digital imaging and molecular spectroscopy in combination with multivariate data analysis methods.
More informationAQT90 FLEX analyzer Lab quality at your fingertips
AQT90 FLEX analyzer Lab quality at your fingertips Just choose your parameters and press start 1 Place the closed sample directly into the inlet. No sample preparation is required. 2 Choose parameters
More informationZeiss Process Gas Analyzer (PGA) based on Ion Trap technology: Zeiss-PGA shows outstanding performances as in-line, real time gas analyzer
Zeiss Process Gas Analyzer (PGA) based on Ion Trap technology: Zeiss-PGA shows outstanding performances as in-line, real time gas analyzer Dr.-Ing. M. Aliman Principal Scientist M. Aliman / ZEISS Agenda
More informationMultidimensional Gas Chromatography: Past, Present & Future
4 th MDC Workshop: TORONTO Multidimensional Gas Chromatography: Past, Present & Future Philip Marriott School of Chemistry, Monash University Discovery Outstanding Researcher Award: Australian Research
More informationMonitoring of Galvanic Replacement Reaction. between Silver Nanowires and HAuCl 4 by In-Situ. Transmission X-Ray Microscopy
Supporting Information Monitoring of Galvanic Replacement Reaction between Silver Nanowires and HAuCl 4 by In-Situ Transmission X-Ray Microscopy Yugang Sun *, and Yuxin Wang Center for Nanoscale Materials
More informationFiner Points of ICP-OES Setup and Operation
Finer Points of ICP-OES Setup and Operation (Part 1) James Bartos Office of Indiana State Chemist Challenges with Fertilizers Broad conc ranges from low ppm to upper % level Want to test all nutrient elements
More informationThe Extrel MAX Systems are UHV-compatible flange mounted Quadrupole Mass
The Extrel MAX Systems are UHV-compatible flange mounted Quadrupole Mass Spectrometers. The Ionizer, Quadrupole Mass Filter, and Detector on a Mounting Flange are designed for inclusion in your experimental
More informationLocalization of microscale devices in vivo using addressable transmitters operated as magnetic spins
SUPPLEMENTARY INFORMATION Articles DOI: 10.1038/s41551-017-0129-2 In the format provided by the authors and unedited. Localization of microscale devices in vivo using addressable transmitters operated
More informationWet particle source identification and reduction using a new filter cleaning process
Wet particle source identification and reduction using a new filter cleaning process Toru Umeda* a, Akihiko Morita b, Hideki Shimizu b, Shuichi Tsuzuki a a Nihon Pall Ltd., 46 Kasuminosato, Ami-machi,
More informationCONTAMINANTES ORGANICOS PERSISTENTES EN FAUNA SILVESTRE: PERSPECTIVA LATINOAMERICANA. Miguel A. Mora, Ph.D. Professor Texas A&M University
CONTAMINANTES ORGANICOS PERSISTENTES EN FAUNA SILVESTRE: PERSPECTIVA LATINOAMERICANA Miguel A. Mora, Ph.D. Professor Texas A&M University Birds as Indicator Species Top of the food chain Photo: The Peregrine
More informationAgilent 6400 Series Triple Quadrupole LC/MS System
Agilent 6400 Series Triple Quadrupole LC/MS System Concepts Guide The Big Picture Agilent Technologies Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by
More informationSPHERICAL NEAR-FIELD SELF-COMPARISON MEASUREMENTS
SPHERICAL NEAR-FIELD SELF-COMPARISON MEASUREMENTS Greg Hindman, Allen C. Newell Nearfield Systems Inc. 1973 Magellan Dr. Torrance, CA 952 ABSTRACT Spherical near-field measurements require an increased
More informationNon-invasive Beam Profile Measurements using an Electron-Beam Scanner
Non-invasive Beam Profile Measurements using an Electron-Beam Scanner W. Blokland and S. Cousineau Willem Blokland for the Spallation Neutron Source Managed by UT-Battelle Overview SNS Accelerator Electron
More informationMaximizing HPLC Speed and Resolution with the new 1100 DAD SL
Welcome to our e-seminar: Maximizing HPLC Speed and Resolution with the new 1100 DAD SL Presenter: Dr. Stefan Schuette Outline Part 1 What do I need to do to maximize HPLC speed? Part 2 What is the performance
More informationVLADIMIR A. NIKIFOROV AND VLADIMIR A. NIKIFOROV. NILU - Norwegian Institute for Air Research, Framsenteret, Tromsø, Norway,
Molecular design of new derivatizing agents for ultra-sensitive ESI(-) LC-MS-MS determination of non-ionic environmental pollutants of emerging concern VLADIMIR A. NIKIFOROV AND VLADIMIR A. NIKIFOROV 3
More informationThermochromic Solid-State Emission of Dipyridyl Sulfoxide Cu(I) Complexes
Supporting Information Thermochromic Solid-State Emission of Dipyridyl Sulfoxide Cu(I) Complexes Christopher M. Brown, Veronica Carta and Michael O. Wolf* Department of Chemistry, University of British
More informationINTRODUCTION We believe that every laboratory working in the field of nanotechnology needs an SEM, therefore we would like to introduce to you our IEM
INTRODUCTION We believe that every laboratory working in the field of nanotechnology needs an SEM, therefore we would like to introduce to you our IEM series of SEM. In short space of time, our device
More informationUV / VIS Spectrophotometer EMCLAB Instruments GmbH
A Professional Manufacturer UV / VIS Spectrophotometer EMCLAB Instruments GmbH EMCLAB Instruments GmbH Bismarckstrasse 120 47057 Duisburg Germany Phone: +49 203 3064042 Fax: +49 203 3064044 E-mail: info@emc-lab.de
More informationSystem Parameter and Performance Comparison Between Agilent 7697A and Agilent G1888A Headspace Samplers for USP <467>
System Parameter and Performance Comparison Between Agilent 7697A and Agilent G888A Headspace Samplers for USP Technical Overview Introduction The Agilent 7697A Headspace Sampler introduced onboard
More informationThe Best Way to Get the Right Answers... is in a Flash
FlashQuant Workstation The Best Way to Get the Right Answers... is in a Flash FlashQuant Workstation: Integrating MALDI Speed with Triple Quad Selectivity 5.03E+02 0.011 1.40E+03 2.680 5.26E+02 0.011 1.30E+03
More informationLecture 7. Lithography and Pattern Transfer. Reading: Chapter 7
Lecture 7 Lithography and Pattern Transfer Reading: Chapter 7 Used for Pattern transfer into oxides, metals, semiconductors. 3 types of Photoresists (PR): Lithography and Photoresists 1.) Positive: PR
More informationSupporting Information for:
Supporting Information for: [Ir(N^N^N)(C^N)L] + : A New Family of Luminophores Combining Tunability and Enhanced Photostability Danielle N. Chirdon, Wesley J. Transue, Husain N. Kagalwala, Aman Kaur, Andrew
More informationAgilent 1260 Infinity Variable Wavelength Detector
Agilent 1260 Infinity Variable Wavelength Detector Features, Technical Details, Specifications and Ordering Details Highest sensitivity for HPLC and RRLC The Agilent 1260 Infinity Variable Wavelength Detector
More informationNexera Method Scouting
Ultra High Performance Liquid Chromatograph Method Scouting System Nexera Method Scouting C190-E150A Maximizing Efficiency for Method Development The Nexera Method Scouting System design is based on the
More informationUV / VIS Spectrophotometer
UV / VIS Spectrophotometer Single Beam Double Beam NANO EMCLAB Instruments GmbH EMCLAB Instruments GmbH Kulturstrasse 55 47055 Duisburg Germany Fon: +49 203 3064042 Fax: +49 203 41504809 E-mail: info@emc-lab.de
More informationEXCALIBUR GROUP, LLC
CORPORATE OFFICERS Stephen L. Wendt, Managing Partner. Mr. Wendt has over 35 years of experience identifying, defining and resolving environmental contamination and related liabilities for industrial,
More informationBias correction of satellite data at ECMWF. T. Auligne, A. McNally, D. Dee. European Centre for Medium-range Weather Forecast
Bias correction of satellite data at ECMWF T. Auligne, A. McNally, D. Dee European Centre for Medium-range Weather Forecast 1. Introduction The Variational Bias Correction (VarBC) is an adaptive bias correction
More informationUse of PFOA in critical photographic applications
Ref. Ares(2014)4210533-15/12/2014 Use of PFOA in critical photographic applications Eddy Michiels Agfa-Gevaert NV Chairman Chemical Compliance WG I&P Europe Imaging and Printing Association State of the
More informationAqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE
Aqualog Water Quality Measurements Made Easy ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING Water
More informationTABLE S1: Association of 19A subtypes with the era after introduction of PCV7 using a multivariable logistic regression analysis
1 SUPPLEMENTAL MATERIAL. 2 3 4 TABLE S1: Association of 19A subtypes with the era after introduction of PCV7 using a multivariable logistic regression analysis Odds Ratio (95% confidence interval) p-value
More informationTracking in seabirds Prof. Dr. Petra Quillfeldt, AG Verhaltensökologie und Ökophysiologie
Tracking in seabirds 25.11.2016 Prof. Dr. Petra Quillfeldt, AG Verhaltensökologie und Ökophysiologie 1 Tracking in seabirds 1. Introduction: seabird ecology 2. Seabirds at sea: Methods and examples of
More informationOG21 TTA4: Barents Sea Gas Condensate Field Development business case. Espen Hauge
OG21 TTA4: Barents Sea Gas Condensate Field Development business case Espen Hauge (espen.hauge@ge.com) Presentation at OG21 conference Kjeller 19.04.2012 How to select business cases? Support the vision
More informationEvaluation of Omega Mag-Bind TotalPure NGS Beads for DNA Size Selection
Evaluation of Omega Mag-Bind TotalPure NGS Beads for Size Selection By Maggie Weitzman, M.Sc. (University of Oregon / GC3F) Disclaimer: Neither Maggie Weitzman, the University of Oregon, nor the Genomics
More informationThermo ImageQuest Version 1.0.1
Thermo ImageQuest Version 1.0.1 User Guide XCALI-97200 Revision B May 2009 2009 Thermo Fisher Scientific Inc. All rights reserved. Xcalibur is a registered trademark of Thermo Fisher Scientific Inc. in
More information