Plug-In Circuit Breakers

Size: px
Start display at page:

Download "Plug-In Circuit Breakers"

Transcription

1 Plug-In Circuit Breakers Types QP, QPH, and HQP with INSTA-WIRE, QN and QNH 14 1-POLE (120V AC) 10 MP MP115 MP115KH MP115KM 20 MP120 MP120KH MP120KM 25 MP125 MP125KH MP125KM 30 MP130 MP130KH MP130KM 35 MP135 MP135KH MP135KM 40 MP140 MP140KH MP140KM 45 MP145 MP145KH MP145KM 50 MP150 MP150KH MP150KM 60 MP160 MP160KH MP160KM 70 MP170 MP170KH MP170KM 2-POLE COMMON-TRIP (120/240V AC) 15 MP215 MP215KH MP215KM 20 MP220 MP220KH MP220KM 25 MP225 MP225KH MP225KM 30 MP230 MP230KH MP230KM 35 MP235 MP235KH MP235KM 40 MP240 MP240KH MP240KM 45 MP245 MP245KH MP245KM 50 MP250 MP250KH MP250KM 60 MP260 MP260KH MP260KM 70 MP270 MP270KH MP270KM 80 MP280 MP280KH 90 MP290 MP290KH MP290KM 100 MP2100 MP2100KH MP2100KM 110 MP2110 MP2110KH MP2110KM 125 MP2125 MP2125KH MP2125KM 2-POLE COMMON-TRIP (240V AC) 15 MPH MPH MPH MPH MPH MPH MPH MPH POLE COMMON-TRIP (240V AC) 15 MP315 MP315KH MP315KM 20 MP320 MP320KH MP320KM 25 MP325 MP325KH 30 MP330 MP330KH MP330KM 35 MP MP340 MP340KH MP340KM 45 MP MP350 MP350KH MP350KM 60 MP360 MP360KH MP360KM 70 MP370 MP370KH MP370KM 80 MP380 MP380KH MP380KM 90 MP390 MP390KH MP390KM 100 MP3100 MP3100KH MP3100KM 1-Pole Type MD-T 3-Pole 2-Pole Type MD-HT Type MD-T and MD-HT 10K AIR 22K AIR Brkr. Amp Catalog Catalog Type Rtg. Number Number MD-T 150 MPD2150 MPD2150R 2-Pole 175 MPD2175 MPD2175R 120/ 200 MPD2200 MPD2200R 240V AC MD-HT 150 MPD2150KH MPD2150RH 2-Pole 175 MPD2175KH MPD2175RH 120/ 200 MPD2200KH MPD2200RH 240V AC HACR rated. UL listed for frequent switching applications (SWD). 120V AC fluorescent lighting. Built to order. Allow 2-3 weeks for delivery.

2 CIRCUIT BREAKERS 2 Circuit Breakers Technical Information Time-Current Characteristic Curves 125 Amp MP Frame,, 1, 2 & 3 Poles For application and coordination purposes only. Based on 40 C ambient cold start. Connected with 4 feet of rated wire (75 C) per terminal. Tested in open air with current in all poles. 60 HZ 1-Pole 120 Volts 60 HZ 2-Pole 120/240 Volts 60 HZ 3-Pole 240 Volts 1 Pole Instantaneous Trip Table Rating Fixed Instantaneous Amperes Trip Amperes & 3 Pole Instantaneous Trip Table Rating Fixed Instantaneous Amperes Trip Amperes 15, Interrupting Rating Symmetrical RMS Amperes Breaker Type 120V 120/240V 240V 1-Pole 10,000 2-Pole 10,000 3-Pole 10,000 Footnotes refer to curve at right. Single pole test data at 25 C in accordance with NEMA standards amperes 50 seconds amperes 80 seconds Sample Instantaneous shown (20 Amp 1, 2 & 3 Pole). For other instantaneous values, see tables above. Industry and Government Specifications Murray circuit breakers meet or exceed the latest edition of the following specifications: Industry NEMA Standard #AB1 UL Standard #489 CSA Standard #C22.1, No. 5.1 U.S. Government Standard #W-C-375B 60 C/75 C Ampacity Rating Murray circuit breakers rated 125A and below are Listed by UL for use with 60 /75 C ampacities. This listing allows use of smaller wire sizes in many applications. Consult NEC Article #310 for application details and limitations. Murray Time-Current Characteristic Curves 125 AMP MP Frame, 1, 2 & 3 Poles Circuit Breaker UL Type Catalog # Prefix UL Type* MP( A) MD-A, MD-H, MD-T, MD-HT MP(15-125A) MP-T, MP-HT, MP-MT, MG, MW MP(Duplex) MH-T MP(Triplex) MH-T MP(GFCI) MP-GT, MP-HGT MP(AFCI) MP-AT, MP-HAT *UL Type is shown on circuit breaker label. Current in percent of breaker rating SWD MP-T circuit breakers are UL Listed SWD, for switching duty use on circuits controlling fluorescent lights NEC Article (D). 2-2

3 Catalog Coding System Full-Size Circuit Breakers PLUG-IN MP = Plug-in MPD = Plug-in Main/Branch MPH = Plug-in 2P, 240VAC MPP = 200A Frame (4-1 Spaces, Adjacent) MQ = 3 4 Format MSA = Surge Arrester NO. OF POLES MP2200GF SPECIALTY SUFFIXES AF = Arc-Fault Circuit Interrupter AS24V = 24V Auxiliary Switch AS = 120V Auxiliary Switch EG = Equipment Ground GF = Ground Fault Circuit Interrupter HID = High-Intensity Discharge KH = 22KAIC KM = 65KAIC KP = 100KAIC NA = Molded Case Switch R = Reverse Handle Operation RH = 22KAIC Reverse Handle Operation RM = 65KAIC Reverse Handle Operation SN = Switched Neutral ST = 120V Shunt Trip ST24V = 24V Shunt Trip T = Tungsten WH = Water Heater 2 CIRCUIT BREAKERS BOLTED FRAME MQJ = QJ2 Frame Reads Direct For all Ratings Half-Size Circuit Breakers MP = Riveted Duplex MP1515N N = Non CTL Duplex CT2 = Common-Trip DUPLEX CAT. NO. 15/ / / / / TRIPLEX OUTSIDE INSIDE CAT. POLES POLES NO Inside poles are common trip. QUADPLEX OUTSIDE INSIDE CAT. POLES POLES NO

4 Interrupting Ratings CIRCUIT BREAKERS 2 RMS Symmetrical Amps (ka) Breaker Maximum Volts AC Page Type Amperage / Number MP-T (1-P) MP-HT (1-P) MP-MT (1-P) MP-T (2-P) MP-T (2-P) MP-HT (2-P) MP-MT (2-P) MP-T (3-P) MP-HT (3-P) MP-MT (3-P) MH-T (Duplex) MH-T (Triplex/Quadplex) MP-AT MP-HAT MP-GT (1-P) MP-HGT (1-P) MP-GT (2-P) MP-HGT (2-P) MP-ET MP-HET MD-T MD-HT MD-MT MD-TR MD-HTR MD-MTR ED-A MPP MPP-HT MPP-MT MPP-PT QJ QJH QJ2-H BQD (1-P) BQD(2,3-P) ED4(1-P) ED4(2,3-P) HED4(1-P15-30A) HED41-P35-70A) HED4(2-P) HED4(3-P) ED6,(2,3-P) FXD HFD JXD JXD HJD LXD HLD MD HMD ND HND

5 Lug Data Circuit Breaker Cables Per Connector Circuit Breaker Type Ampere Rating Connector Wire Range LOAD SIDE MP-T, MP-HT, MP-MT 7 2 #18 #14 CU 10 2 #16 #14 CU 1 #14 #8 AWG Cu #14 #6 AWG Cu #14 #6 AWG Al #8 #4 AWG Cu #8 #2 AWG Al 1 #4 #1/0 AWG Cu #2 #1/0 AWG Al 1 #2 #1/0 AWG Cu #1/0 #2/0 AWG Al MH-T 1 #14 #8 AWG Cu #8 AWG CU-Al #14 #10 AWG Cu MP-GT, MP-HGT, MP-ET, MP-HET MP-AT, MP-HAT, BAF, BAFH #14 #12 AWG Cu 1 #12 #10 AWG Al MSQ #14 #8 AWG Cu Only #14 #12 AWG Cu #12 #10 AWG Al #10 #8 AWG Cu 1 #10 #6 AWG Al BLF, BLHF, BLE, BLEH MD-T, MD-HT, MD-MT, MD-PT, MD-TR, MD-HTR, MD-MTR, MD-PTR #1 300kcmil Cu-Al M #4 3/0 AWG Cu-Al #4 3/0 AWG Cu-Al M #1 300kcmil Cu-Al MPP-T, MPP-HT, MPP-MT, MPP-PT 125 MQ, MQH, MQL #1 300kcmil Cu-Al #1 300kcmil Cu-Al 1 #1 AWG Cu 1 #2/0 AWG Al #1/0 AWG Cu 1 #3/0 AWG Al #2/0 AWG Cu 1 #4/0 AWG Al #3/0 AWG Cu 1 250kcmil AWG Al #4/0 AWG Cu 1 300kcmil AWG Al #6 300kcmil Cu #4 300kcmil Al 2 CIRCUIT BREAKERS 2-5

UTE100 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTE100 NT FMU 100A 3P LL LSIS UL MCCB

UTE100 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTE100 NT FMU 100A 3P LL LSIS UL MCCB PRODUCT CATALOG SUSOL SUPER SOLUTION SELECTION GUIDE UTE00 CATALOG NUMBERING [PRODUCT SELECTION] UTE00 NT FMU 00A 3P LL UL SERIES & FRAME: Susol 00AF PERFORMANCE Rating 80% 00% ka SUFFIX UL : UL 20/ 240Vac

More information

Bulletin 140U Molded Case Circuit Breakers

Bulletin 140U Molded Case Circuit Breakers Bulletin 40U Multitap End Cap Optional Optional Optional 40U-J-MTLA 40U-J-MTL6A 40U-J-ECM Aluminum Aluminum Molded Housing /4 screw /4 screw lb-in lb-in.6 N m.6 N m Cu/Al Cu/Al 60/7 C 60/7 C () (6) (A)

More information

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

Note: The let-through of the protective device must be equal to or less than the short-circuit current rating of the component being protected.

Note: The let-through of the protective device must be equal to or less than the short-circuit current rating of the component being protected. CONDUCTOR SHORT-CIRCUIT PROTECTION Introduction: This paper analyzes the protection of wire from fault currents. It gives the specifier the necessary information regarding the short-circuit current rating

More information

PowerPact H-, J-, and L-Frame Circuit Breakers General Information. Vibration. Electromagnetic disturbances. Tropicalization

PowerPact H-, J-, and L-Frame Circuit Breakers General Information. Vibration. Electromagnetic disturbances. Tropicalization General Information Vibration PowerPact H-, J-, and L-frame devices resist mechanical vibration. Tests are carried out in compliance with standard UL 489 SA and SB for the levels required by merchant-marine

More information

3Ø Short-Circuit Calculations

3Ø Short-Circuit Calculations 3Ø Short-Circuit Calculations Why Short-Circuit Calculations Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective

More information

Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System

Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System Technical Data TD008010EN Supersedes February 2016 Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System The information below is taken directly from the National Electrical CodeT (NEC)

More information

B. Manufacturers: Square-D, G.E. or Westinghosue.

B. Manufacturers: Square-D, G.E. or Westinghosue. SECTION 16470 - PANELBOARDS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. a.

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Short Circuit Current Calculations

Short Circuit Current Calculations Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that

More information

Ampere Rating LAL MAL* NAL. 2-pole. 3-pole. Catalog No. Price $ QO300 QOU300 QO3000 QOU3000 QOU30001

Ampere Rating LAL MAL* NAL. 2-pole. 3-pole. Catalog No. Price $ QO300 QOU300 QO3000 QOU3000 QOU30001 MAG-GARD Motor Circuit Protector Class, 8, 6, 68 Instantaneous trip magnetic onl circuit breakers have a single adjustment which simultaneousl sets the magnetic trip level of each individual pole. MAG-GARD

More information

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION! PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling

More information

Short-Circuit Current Calculations

Short-Circuit Current Calculations Basic Point-to-Point Calculation Procedure Step. Determine the transformer full load amps (F.L.A.) from either the nameplate, the following formulas or Table : Multiplier = 00 *% Z transformer Step 2.

More information

NEMA Size 1 Cat. No. CN55DN3AB

NEMA Size 1 Cat. No. CN55DN3AB -80 Contactors and Contents Description Product Family Overview Page Product Description....... -78 Features................ -78 Standards and Certifications........... -78 Selection.............. -79

More information

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56 1. Two Electrical Technicians are discussing markings that are required for AC wiring. Tech A says that AC conductors must be rated for 600 volts and must have their jackets and individual conductors marked

More information

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.1 SUMMARY DISCONTINUED PRODUCT GUIDE SPECIFICATIONS 15-75 kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL These specifications describe requirements for a complete power conditioning and

More information

Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL77/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the UL489/CSA C22.2 No.5-02,

More information

PF/PFQ. High Amperage plug and receptacle. Main Advantages

PF/PFQ. High Amperage plug and receptacle. Main Advantages High Amperage plug and receptacle Main Advantages u u u Durable in harsh environments Safety features provide maximum protection Easy plug insertion and removal Watch the PF video and other product videos

More information

Warehouse Stock Transformers

Warehouse Stock Transformers Warehouse Stock s Warehouse Stock Buck-Boost Application Description and The Buck-Boost has four separate windings, two-windings in the primary and two-windings in the secondary. The unit is designed for

More information

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS) WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS) 1 PART 1: GENERAL This section describes materials and installation requirements for low voltage

More information

Distribution/Substation Transformer

Distribution/Substation Transformer Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation

More information

Straight Isolation - Plug In (171 Series)

Straight Isolation - Plug In (171 Series) Straight Isolation - Plug In (171 Series) LINE ISOLATION PLUG & RECEPTACLE TRANSFORMERS (115V to 115V) Primary 115C, 50/60 Hz., Secondary 115C Electrostatic shield between primary & secondary. Hi-pot tested

More information

NZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data

NZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data Circuit Breakers, 09/098 Molded case circuit breakers 3 pole NZMH 4-...-C 1) NZM6B.../ZM6A...- Frame size A 80 125 125 IEC 60 947-2 Electrical Ratings Rated impulse withstand voltage U imp V 8000 8000

More information

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker T e c h n i c a l C a t a l o g u e MCCB Moulded Case Circuit Breaker contents general overview... 2 feature - company profile and certifications... 6 MCCB - NF series circuit breaker, double repulsion

More information

User's Guide. AC Circuit Load Tester. Model CT70

User's Guide. AC Circuit Load Tester. Model CT70 User's Guide AC Circuit Load Tester Model CT70 Introduction Congratulations on your purchase of the CT70 AC Circuit Load Tester. This device can detect circuit and wiring problems such as: Poor ground

More information

Liebert Datawave. GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL

Liebert Datawave. GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL 1.1 SUMMARY GUIDE SPECIFICATIONS 100-200 kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL These specifications describe requirements for a complete power conditioning and distribution system,

More information

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings Table of Contents Page Selection Table.... 2 Power Distribution Blocks PDBFS Series....................................3-8

More information

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL series

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL series IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL 61-160 series The Service Information provides the following information Precautions and safety information Specifications Performance test procedure Calibration

More information

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit.

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit. ECET4520 Exam II Sample Exam Problems Instructions: This exam is closed book, except for the reference booklet provided by your instructor and one (8.5 x11 ) sheet of handwritten notes that may not contain

More information

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable: Reclosers NOVA Three-Phase Recloser Functional Specification Guide Functional specification for NOVA three-phase recloser 1. Scope This specification describes the features and ratings of the NOVA recloser.

More information

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer PANELMDP Main Distribution Panel Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Product Type PANELMDP Eaton Corp 1.0 (lbs/each) Three Phase Energy Efficient

More information

Variable Transformers Product Design & Engineering Data

Variable Transformers Product Design & Engineering Data Variable Transformers Product Design & Engineering Data Product Design & Engineering Data Type 1010B Cutaway General Information STACO ENERGY PRODUCTS CO. is a leading manufacturer of variable transformers,

More information

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer PART 1: GENERAL 1.01 Transformer A. This section includes liquid filled, pad mounted distribution transformers with primary voltage of 12kV or 4.16kV (The University will determine primary voltage), with

More information

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design

More information

The Variable Threshold Neutral Isolator (VTNI)

The Variable Threshold Neutral Isolator (VTNI) The Variable Threshold Isolator (VTNI) Installation Instructions INTRODUCTION The is designed specifically for installation between the primary neutral of a power utility distribution system and the secondary

More information

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 S10N06P0P KVA 1PH 10/40V 16/3V Buck Boost Transformer Eaton Corp Catalog Manufacturer Description Weight per unit Product

More information

AC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10

AC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10 Bulletin -P Product Selection/ Accessories Units Description DX Arrangement DX K Continuous Carrying Current [A] No cartridge Cat. No. -PLL -PLL AC-Operated Units -PKLL DY DY K DX Reset Input DX K No cartridge

More information

SINGLE-PHASE VSV SWITCH

SINGLE-PHASE VSV SWITCH May 2006 Supercedes: March 2006 SINGLE-PHASE VSV SWITCH INSTALLATION AND OPERATING MANUAL Table of Content: Page I. General...2 II. Specifications...2 III. Installation...2 IV. Maintenance...4 V. VSV Power

More information

Bulletin 700-RTC Solid-State Timing Relay

Bulletin 700-RTC Solid-State Timing Relay Bulletin 700-RTC Solid-State Timing Relay Bulletin 700 RTC Solid State Timing Relay Timing functions 8 ON-delay 8 OFF-delay Timing ranges Seconds: 0.05 2, 0.2 8, 0.4 30, 2 120 Minutes: 0.015 1, 0.06 4,

More information

More Complete Protection

More Complete Protection More Complete Protection AFCI, GFCI and Dual Function AFCI/GFCI Receptacles and Circuit Breakers THE FUTURE IS ON GFCI Protection Leviton is the world s leading manufacturer of residential and commercial

More information

Controls Contactors and Contactor Assemblies Special Applications

Controls Contactors and Contactor Assemblies Special Applications Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for

More information

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3. 6-4 Freedom Pump Panels Circuit reaker R Enclosure / -Phase Magnetic / Interchangeable eater OLR These ECN Irrigation Pump Controllers feature the Cutler-ammer Freedom Series starters. They have a AND/OFF/AUTO

More information

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz POWER QUALITY INSTRUCTION MANUAL Type SWF Sine Wave Filters 690 Volts, 50Hz Page 2 of 24 Contents 1. Introduction & SAFETY 2. Theory of operation 3. Typical results of the Sine Wave Filters 4. Transportation,

More information

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87 Motor Control Motor Control............................. Adjustable Frequency AC Drives............................. Synchronous............................................ Starters (Medium Voltage)..................................

More information

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters Section [26 35 26][16280] Active Harmonic Filters (Low Voltage) Part 1 General 1.1 Summary A. Scope: Provide design and engineering, labor,

More information

SECTION PANELBOARDS

SECTION PANELBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section

More information

Medium voltage circuit breaker technical guide

Medium voltage circuit breaker technical guide IEC 56-1987 - ANSI C37-06 1987 COMPARISON CONTENTS page 1 - Rated voltage 3 2 - Rated isolating level 3 3 - Rated voltage during normal running 4 4 - Allowable short time current 4 5 - Allowable current

More information

P48G11S05P 5KVA 1PH 480V - 120/240V Mini Power Center

P48G11S05P 5KVA 1PH 480V - 120/240V Mini Power Center 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 P48G11S05P 5KVA 1PH 480V - 10/40V Mini Power Center Eaton Corp Catalog Number Manufacturer Description Weight per unit

More information

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers .5 Transformers Distribution Transformers Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Totally Enclosed Non-Ventilated Transformers Product Description Note: The following pages provide listings

More information

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING 1.0 General This specification covers the electrical characteristics and general

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings Table of Contents Page Selection Table.... 2 Power Distribution Blocks PDBFS Series....................................3-8

More information

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262) APQline Active Harmonic Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Power electronic equipment and AC-DC power conversion equipment contribute

More information

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1 INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 02/2010 MODELS 201A-AU 201-575-AU II_201A-AU_B1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580 fax (605)

More information

Gen Purpose Wiring Devices - Gen Purpose Recept & Surge Prot

Gen Purpose Wiring Devices - Gen Purpose Recept & Surge Prot 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VGFD20A 20A Alm Gfci RCPT Eaton Wiring Devices Catalog Number VGFD20A Manufacturer Eaton Wiring Devices Description Circuit

More information

GROUNDING EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA

GROUNDING EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA PAGE 86 5000 500 5040 5060 5080 500 50 540 560 580 500 540 560 580 5300 5340 5360 5380 5400 5440 5460 5480 5500 5540 5560 700 705 75 70 75 730 740 745 750 755 765 770 775 780 790 7300 7305 730 C 00 C 0

More information

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description General-Purpose Encapsulated.4 Type EP 3 5 Contents Description General-Purpose Encapsulated Catalog Selection................ Product Selection....................... Single-Phase..........................

More information

Spa Control Troubleshooting Guide

Spa Control Troubleshooting Guide Spa Control Troubleshooting Guide Model: RS, Voltage: 0V Major System Components TOPSIDE PANEL SYSTEM PACK FAULT CIRCUIT INTERRUPTER (GFCI) GFCI models vary in size and style. Your GFCI may look different.

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches 240 Volt Class 110 Visible blade heavy duty safety switches are designed for application where maximum performance and continuity of service are required. All heavy duty safety

More information

Alternating Current Power

Alternating Current Power Chapter 4 Alternating Current Power MElec-Ch4-1 Overview What is Alternating Current AC Hazards AC Power Requirements Shoreside Utility System On-Board Generators MElec-Ch4-2 What is Alternating Current

More information

$

$ ircuit reakers or I-LIN Panelboards and Switchboards lass 0, 5, 70, 830 8 PNLORS 8-32 LI3 7.5 in (190 mm) L 7.5 in (190 mm) M, MH 2- and 3-Pole 9 in (229 mm) N, N 2- and 3-Pole 15 in (381 mm) Square ll

More information

SINGLE-PHASE VSV SWITCH

SINGLE-PHASE VSV SWITCH Revision: September 2009 Supersedes: August 2007 SINGLE-PHASE VSV SWITCH INSTALLATION AND OPERATING MANUAL Table of Content: Page I. General...2 II. Specifications...2 III. Installation...3 IV. Maintenance...5

More information

Submittal Transmittal

Submittal Transmittal Commonwealth Engineers, Inc. 7256 Company Drive Indianapolis IN 46237 United States Submittal Transmittal PROJECT: SUBJECT: Waynetown - Water-Strmwtr Imprv-Div A J13046-A DS-23-01 A_Engine Generators &

More information

Table K. Input/Output Ratings & External Wiring Requirements for the Powerware /80 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220

Table K. Input/Output Ratings & External Wiring Requirements for the Powerware /80 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220 Table K. Input/ Ratings & External Wiring Requirements for the 9390-/ Units Rating 50/0 Hz Basic Unit Rating at 0.9 lagging pf load Input and Bypass Input Rectifier (0.98 min. pf) plus Recharge Current

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I have a 500 KVA generator, with no overcurrent protection

More information

TEST PROCEDURE FOR THE RMS-2012AF PROGRAMMABLE LOGIC CONTROLLER USING AN AMPTECTOR SECONDARY TEST SET.

TEST PROCEDURE FOR THE RMS-2012AF PROGRAMMABLE LOGIC CONTROLLER USING AN AMPTECTOR SECONDARY TEST SET. 1 TEST PROCEDURE FOR THE RMS-2012AF PROGRAMMABLE LOGIC CONTROLLER USING AN AMPTECTOR SECONDARY TEST SET. The Amptector Adapter Plug, shown above, is available from WESTRIP to facilitate the testing of

More information

Power Distribution Blocks with Short-Circuit Current Ratings

Power Distribution Blocks with Short-Circuit Current Ratings Power Distribution Blocks with Short-Circuit Current Ratings General Information: The requirements of the 005 National Electric Code (NEC) and UL508A now require many electrical panels to carry a Short

More information

System Components and Accessories

System Components and Accessories OutBack Panel Mount Breakers Panel mounted hydraulic-magnetic type breakers that can be used for DC sources, inverters or load circuits. Model Current Voltage Branch Terminals Width Rating Rating Circuit

More information

Item Number No. Poles NO/NC V DC 50/60 Hz. Aux Contactor NO/NC Resistive/ Inductive Amps Price. AF Series

Item Number No. Poles NO/NC V DC 50/60 Hz. Aux Contactor NO/NC Resistive/ Inductive Amps Price. AF Series ABB Contactors Fits 35mm DIN rail Touch Safe Design Compact Design Captive Terminal Screws Built in surge protection (AF series only) Magnetic coil (AE series only) Electronically controlled coil (AE series

More information

Supplemental Motor Protection Devices Specifications

Supplemental Motor Protection Devices Specifications Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Page 809S/813S/814S/817 Dedicated Function Motor Protection Relays 2 Product

More information

Solid-state Contactor Specifications

Solid-state Contactor Specifications Technical Data Solid-state Contactor Specifications Bulletin Number 156 Topic Page Topic Page Catalog Number Explanation 2 Dual- and Three-phase Devices 25 Single-phase Devices 3 Product Selection 25 Product

More information

Page 13-2 Page Page 13-7

Page 13-2 Page Page 13-7 Page -2 Page -6 MINIATURE CIRCUIT BREAKERS UP TO 63A 1P, 1P+N, 2P, 3P and 4P versions IEC rated current In: 1-63A IEC short-circuit capacity Icn: 10kA (6kA for 1P+N) Trip characteristic curve: Type B,

More information

Straight Isolation - Hard Wired (169 Series)

Straight Isolation - Hard Wired (169 Series) LINE ISOLATION TRANSFORMERS (115V to 115V) Primary 115C, 60 Hz., Secondary 115C Electrostatic shield between primary & secondary Connection by flexible leads, 8" minimum length Perfect for circuit isolation

More information

2.5. Transformers. Mini Power Centers. Distribution Transformers. Product Description

2.5. Transformers. Mini Power Centers. Distribution Transformers. Product Description Distribution.5 Contents Description Motor Drive Isolation............ Mini Power Centers Standards and Certifications............... Catalog Number Selection................ Product Selection.......................

More information

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv) Outdoor Transmission (69 kv through 230 kv) Detailed Functional Specification Guide 1.0 GENERAL 1.01 The circuit-switcher shall conform to the following specification. 1.02 The circuit-switcher shall be

More information

Bulletin 700-R -RM Sealed Switch Relays

Bulletin 700-R -RM Sealed Switch Relays Bulletin 700-R -RM Sealed Switch Relays Bulletin 700 R, RM Sealed Switch Relays Sealed contacts Extremely long mechanical and electrical life Hazardous locations Class 1, Div Groups A, B, C, D Harsh environments

More information

{40C54206-A3BA D8-8D8CF }

{40C54206-A3BA D8-8D8CF } Informative Annex D Incident Energy and Arc Flash Boundary Calculation Methods This informative annex is not a part of the requirements of this NFPA document but is included for informational purposes

More information

+ 24V 3.3K - 1.5M. figure 01

+ 24V 3.3K - 1.5M. figure 01 ELECTRICITY ASSESSMENT 35 questions Revised: 08 Jul 2013 1. Which of the wire sizes listed below results in the least voltage drop in a circuit carrying 10 amps: a. 16 AWG b. 14 AWG c. 18 AWG d. 250 kcmil

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

Table of Contents. Facility EMI Filter Products

Table of Contents. Facility EMI Filter Products Table of Contents Filter Selection Guide Facility EMI Filters...............................................4, 5 Signal/Data/Control Filters........................................6, 7 Technical Notes................................................8,

More information

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION SECTION 16715 COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION PART 1 - GENERAL 1.01 SECTION DESCRIPTION AND BASIC REQUIREMENTS A. The Electrical Power Distribution System provides power distribution from

More information

Low voltage circuit breakers

Low voltage circuit breakers Comprehensive Catalogue 2006 Super Solution Low voltage circuit breakers A-4. Technical information TD & TS MCCB Index Temperature derating Power dissipation / Resistance Application Primary use of transformer

More information

2.1. Product Description

2.1. Product Description .1 NEMA TP-1 Energy-Efficient Type DT-3 Contents Description NEMA TP-1 Energy-Efficient Features, Benefits and Functions........... Standards and Certifications............... Catalog Selection................

More information

Article 225: Outside Branch Circuits And Feeders

Article 225: Outside Branch Circuits And Feeders Part C: Code Book Questions Article 225: Outside Branch Circuits And Feeders 1.! Open (individual) aerial overhead conductors shall be insulated or covered when within! feet of a building.! (a) 10! (c)

More information

Supplemental Motor Protection Devices Table of Contents

Supplemental Motor Protection Devices Table of Contents Supplemental Motor Protection Devices Table of Contents Supplemental Motor Protection Devices Bulletin 0S/S//... Page - Bulletin 0 Arcing Ground Fault Detection System: Adjustable Trip from A... Page -

More information

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017 Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017 NAME: LOCATION: 1. The primitive self-inductance per foot of length

More information

NEMA Contactor and Starter Specifications

NEMA Contactor and Starter Specifications Technical Data NEMA Contactor and Starter Specifications Bulletins 00, 0, 0, 0, 06, 06X, 07, 07X, 09,,, E/F/G, E/F/G Topic Page Specifications Electrical Ratings Mechanical Ratings, Construction, Environmental

More information

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC) Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts,

More information

Supplemental Motor Protection Devices Specifications

Supplemental Motor Protection Devices Specifications Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Bulletin 809S/813S/814S/817S 2 Page Product Line Overview 2 Cat. No. Explanation

More information

PKZ 2 Manual Motor Protectors Technical Data

PKZ 2 Manual Motor Protectors Technical Data 08/066 PKZ 2 Manual Motor Protectors General Standards UL 508, CSA C 22.2 No. 14, IEC/EN 60 947, VDE 0660 GL, LR, DNV, PRS, BV, RINA, RS, EZU, MEEI Climatic proofing Damp heat, constant, to IEC 60 068-2-3

More information

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 3 4.0 Sectionalizer Construction... 4 5.0 Mechanism... 6 6.0 Solid Dielectric

More information

NOsparc! MHXAC1F120! MHXAC1F240! MHXAC1F480 PATENTS AND PATENTS PENDING. Contact Arc Suppressor

NOsparc! MHXAC1F120! MHXAC1F240! MHXAC1F480 PATENTS AND PATENTS PENDING. Contact Arc Suppressor NOsparc MHXAC1F120 MHXAC1F240 MHXAC1F480 PATENTS AND PATENTS PENDING Contact Arc Suppressor Contact Arc Suppression for AC Power Relays, Contactors, and Snap-Action Switches User Manual 104-0017E 2014,

More information

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947 Motor--protective circuit--breaker system J7M -AM System Rated operational current 25 A. Switching capacity up to 10 A, 100 ka/415 V. Switching capacity 16 A, 20 A, 25 A, 16 ka/415 V. Fixed short--circuit

More information

Electrical Power Transfer Products

Electrical Power Transfer Products Manufacturing, Inc. Overhead Holders & Stops Hospital Push/Pull Latches Electro-Magnetic Door Holders Aluminum Continuous Geared Hinges Stainless Steel Continuous Pin & Barrel Hinges Stainless Steel Edge

More information