Project NO Date: March 16, ADDENDUM NO. 3 GRAYSON PARK RENOVATIONS Page 1 of 1 DEPT. OF PLANNING, ENG & PERMITS GENERAL

Size: px
Start display at page:

Download "Project NO Date: March 16, ADDENDUM NO. 3 GRAYSON PARK RENOVATIONS Page 1 of 1 DEPT. OF PLANNING, ENG & PERMITS GENERAL"

Transcription

1 2301 1st Avenue North Suite 101 Birmingham, Alabama ph fx Project NO Date: March 16, 2015 ADDENDUM NO. 3 GRAYSON PARK RENOVATIONS Page 1 of 1 BIDS RECIEVED: ARCHITECTURAL DIVISION TIME: 4pm CTS DEPT. OF PLANNING, ENG & PERMITS DATE: March 19, 2015 ANDRE V. BITTAS, DIRECTOR Room 215 City Hall ALAN TERRY OGLESBY, NCARB, CITY ARCHITECT THIS ADDENDUM IS DIRECTED TO ALL PRIME BIDDERS, AND ALL OTHERS TO WHOM DRAWINGS AND SPECIFICATION HAVE BEEN ISSUED. THIS ADDENDUM FORMS A PART OF THE CONTRACT DOCUMENTS. THE FOLLOWING CONDITIONS TAKE PRECEDENCE OVER ANY CONFLICTING CONDITIONS IN THE DRAWINGS AND SPECIFICATIONS. THE DRAWINGS AND SPECIFICATIONS ARE HEREBY AMENDED IN THE FOLLOWING PARTICULARS GENERAL Item 1: The Project duration has been changed from sixty (60) days to ninety (90) days. Item 2: The drawing titles for the two proposed small pavilions were modified to indicate that they are Alternates # s 1 and 2. Item 3: A note was added to the unisex toilet plan to provide heaters to protect exposed pipes. Item 4: CTX Incorporated and Modular Connections, LLC have been approved a manufacturers for the prefab unisex toilet. Item 5: The drawings for the existing pavilion were revised to indicate that the roof decking, trusses and beams would be used as part of the renovation. The high pitched area of the roof is to be removed. The metal roof and any damaged wood (decking, trusses or beams) will be replaced. Item 6: The parking adjacent to the pool house was deleted from the job. The civil and electrical drawings were sealed signed and dated. Item 7: The note on the civil drawings calling for the existing swings to be replaced was deleted. Item 8: The civil drawing was revised to indicate electrical items connecting to the existing panel in the pool house. BIRMINGHAM PITTSBURGH INDIANAPOLIS

2 2301 1st Avenue North Suite 101 Birmingham, Alabama ph fx ATTACHMENTS Item 1: Sealed, signed and dated Civil Sheets C1.0 Project Notes, C2.0 Site & Utility Plan, C3.0 - Grading and Erosion Control Plan, C4.0 Details and C4.1 Details. Item 2: Revised Architectural Sheets A1.1 Site Plan, A1.2 Enlarged Plans and A2.1 Elevations. Item 3: Sealed, signed and dated Electrical Sheets E101 Electrical Legend and Details and E102 Electrical Site Plan and Details. Item 4: Specifications and drawings for approved unisex toilet manufacturers (Modular Connections, LLC and CXT Incorporated). There to be no windows in the selected unit. Receipt of this Addendum #3 must be noted in the proper location on Proposal form. END OF ADDENDUM BIRMINGHAM PITTSBURGH INDIANAPOLIS

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31 Dorsey + Architects & Associates Inc st Avenue North, Suite 101 Birmingham, Alabama Ph Fax (205) (205) Clay R. Dorsey, AIA cdorsey@dorseyarchitects.com SEAL 03/13/2015 OWNER CITY OF BIRMINGHAM Birmingham, Alabama PROJECT IDENTIFICATION Project No Grayson Park Renovations Grayson Park 1041 Five Mile Road Birmingham, Al CONSTRUCTION DOCUMENTS MATERIAL RATE PER ACRE MARK STRAW (NO SEED) TONS BARK (CAN USE A BLOWER) 35 CUBIC YDS DATE DESCRIPTION ISSUE DATE: 02/06/2015 PROJECT NO: MC DRAWN BY: CHECKED BY: ZR SPECIES SEEDING RATE/AC PLS BERMUDAGRASS, COMMON 10 LBS SPECIES SEEDING RATE/AC PLS BERMUDAGRASS, COMMON 10 LBS TYPICAL SEEDING DATES APR 1-JUL 1 TYPICAL SEEDING DATES These drawings and/or specifications, and all ideas, designs, inventions, and arrangements represented thereon are and shall remain the sole and exclusive property of The Architect and no part thereof shall be copied, disclosed to others or used in connection with any other work or project other than the specified project for which they have been prepared and developed, without prior written consent of The Architect. Visual contact with these plans and /or specifications constitues conclcusive evidence of acceptance of these restrictions. SHEET TITLE APR 1-JUL 1 *NOTE: FOR TEMPORARY AND PERMANENT SEEDING, CONTRACTOR SHALL VERIFY SPECIES, SEEDING RATES, AND SEEDING DATES WITH THE ALABAMA SOIL AND WATER CONSERVATION COMMITTEE AND PARTNERS' "FIELD GUIDE FOR EROSION AND SEDIMENT CONTROL ON CONSTRUCTION SITES IN ALABAMA" - FIRST EDITION, AUGUST 2004 Sheet of, Series Sheets c Copyright 2014, Dorsey Architects and Associates, Inc., st Avenue North, Suite 101

32 F I V E M I L E R O A D ' X X X X X X X X IP 4.97' 60' SOUTHERN NATURAL GAS CO. EASEMENT ' GRAVEL DRIVE 21.00' 4.00' 65.00' 24.00' 18.00' 13.00' PLAYGROUND AREA 8.00' 35.00' 34.00' Dorsey Architects & Associates Inc st Avenue North, Suite 101 Birmingham, Alabama Ph Fax (205) (205) Clay R. Dorsey, AIA cdorsey@dorseyarchitects.com SEAL + 03/13/2015 OWNER ACREAGE '0" G R A Y S O N P A R K W W W W W W W W W W W EXISTING ASPHALT PARKING 53.92' 15.49' '10" 35.12' '38" 5.00' 86.15' 65.74' 99 18'38" 33.03' 24.00' 10.00' 25.00' POOL AREA W/ FENCING 34.00' 14.00' 90 0'0" ' R I G H T - O F - W A Y F O R P U B L I C U T I L I T I E S CITY OF BIRMINGHAM Birmingham, Alabama MARK PROJECT IDENTIFICATION DATE ISSUE DATE: 02/06/2015 PROJECT NO: DRAWN BY: Project No Grayson Park Renovations Grayson Park 1041 Five Mile Road Birmingham, Al CHECKED BY: CONSTRUCTION DOCUMENTS MC ZR DESCRIPTION These drawings and/or specifications, and all ideas, designs, inventions, and arrangements represented thereon are and shall remain the sole and exclusive property of The Architect and no part thereof shall be copied, disclosed to others or used in connection with any other work or project other than the specified project for which they have been prepared and developed, without prior written consent of The Architect. Visual contact with these plans and /or speci- fications constitues conclcusive evidence of acceptance of these restrictions. SHEET TITLE SCALE: 1" = 20' F I V E M I L ' Sheet of, Series Sheets c Copyright 2014, Dorsey Architects and Associates, Inc., st Avenue North, Suite 101

33 ACREAGE F I V E M I L E R O A D SL ' X X X '0" X X SL X X X G R A Y S O N P A R K EXISTING ASPHALT PARKING SF SF IP ' SF SF SF SF ' GRAVEL DRIVE SF SF SF SF SF SF SF SF PLAYGROUND AREA SF SF SF SF POOL AREA W/ FENCING ' R I G H T - O F - W A Y F O R P U B L I C U T I L I T I E S MARK Dorsey Architects & Associates Inc st Avenue North, Suite 101 Birmingham, Alabama Ph Fax DATE ISSUE DATE: 02/06/2015 PROJECT NO: DRAWN BY: CHECKED BY: (205) (205) Clay R. Dorsey, AIA cdorsey@dorseyarchitects.com SEAL OWNER CITY OF BIRMINGHAM Birmingham, Alabama PROJECT IDENTIFICATION Project No Grayson Park Renovations Grayson Park 1041 Five Mile Road Birmingham, Al CONSTRUCTION DOCUMENTS MC ZR DESCRIPTION These drawings and/or specifications, and all ideas, designs, inventions, and arrangements represented thereon are and shall remain the sole and exclusive property of The Architect and no part thereof shall be copied, disclosed to others or used in connection with any other work or project other than the specified project for which they have been prepared and developed, without prior written consent of The Architect. + 03/13/2015 Visual contact with these plans and /or speci- fications constitues conclcusive evidence of acceptance of these restrictions. SHEET TITLE SF TYPE 1 SILT FENCE SCALE: 1" = 20' F I V E M I ' Sheet of, Series Sheets c Copyright 2014, Dorsey Architects and Associates, Inc., st Avenue North, Suite 101

34 Dorsey Architects & Associates Inc st Avenue North, Suite 101 Birmingham, Alabama Ph Fax (205) (205) Clay R. Dorsey, AIA cdorsey@dorseyarchitects.com SEAL 03/13/2015 OWNER CITY OF BIRMINGHAM Birmingham, Alabama PROJECT IDENTIFICATION Project No Grayson Park Renovations Grayson Park 1041 Five Mile Road Birmingham, Al CONSTRUCTION DOCUMENTS MARK DATE DESCRIPTION ISSUE DATE: 02/06/2015 PROJECT NO: DRAWN BY: CHECKED BY: MC ZR Visual contact with these plans and /or speci- fications constitues conclcusive evidence of acceptance of these restrictions. These drawings and/or specifications, and all ideas, designs, inventions, and arrangements represented thereon are and shall remain the sole and exclusive property of The Architect and no part thereof shall be copied, disclosed to others or used in connection with any other work or project other than the specified project for which they have been prepared and developed, without prior written consent of The Architect. SHEET TITLE Sheet of, Series Sheets c Copyright 2014, Dorsey Architects and Associates, Inc., st Avenue North, Suite 101

35 ROADWAY SECTION A - A FILTER FABRIC Dorsey Architects & Associates Inc st Avenue North, Suite 101 Birmingham, Alabama Ph Fax (205) (205) Clay R. Dorsey, AIA cdorsey@dorseyarchitects.com SEAL A A PLAN 03/13/2015 OWNER CITY OF BIRMINGHAM Birmingham, Alabama PROJECT IDENTIFICATION Project No Grayson Park Renovations Grayson Park 1041 Five Mile Road Birmingham, Al CONSTRUCTION DOCUMENTS MARK DATE DESCRIPTION ISSUE DATE: 02/06/2015 PROJECT NO: DRAWN BY: CHECKED BY: MC ZR Visual contact with these plans and /or speci- fications constitues conclcusive evidence of acceptance of these restrictions. These drawings and/or specifications, and all ideas, designs, inventions, and arrangements represented thereon are and shall remain the sole and exclusive property of The Architect and no part thereof shall be copied, disclosed to others or used in connection with any other work or project other than the specified project for which they have been prepared and developed, without prior written consent of The Architect. SHEET TITLE Sheet of, Series Sheets c Copyright 2014, Dorsey Architects and Associates, Inc., st Avenue North, Suite 101

36 PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT Dorsey Architects & Associates Inc st Avenue North, Suite 101 Birmingham, Alabama Ph Fax (205) (205) Clay R. Dorsey, AIA cdorsey@dorseyarchitects.com SEAL OWNER CITY OF BIRMINGHAM Birmingham, Alabama 1 A1.2 PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT 1 A1.2 6 A1.2 2 A1.2 PROJECT IDENTIFICATION Project No Grayson Park Renovations Grayson Park 1041 Five Mile Road Birmingham, Al CONSTRUCTION DOCUMENTS PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT 1 3/16/15 ADDENDUM NO. 1 MARK DATE DESCRIPTION ISSUE DATE: 2/6/15 PROJECT NO: DRAWN BY: WGH CHECKED BY: WGH These drawings and/or specifications, and all ideas, designs, inventions, and arrangements represented thereon are and shall remain the sole and exclusive property of The Architect and no part thereof shall be copied, disclosed to others or used in connection with any other work or project other than the specified project for which they have been prepared and developed, without prior written consent of The Architect. Visual contact with these plans and /or speci- fications constitues conclcusive evidence of acceptance of these restrictions. N 1 SITE PLAN 1/32" = 1'-0" SHEET TITLE SITE PLAN A1.1 Sheet of, Series Sheets c Copyright 2014, Dorsey Architects and Associates, Inc., st Avenue North, Suite 101 PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

37 PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT Dorsey Architects & Associates Inc st Avenue North, Suite 101 Birmingham, Alabama Ph Fax (205) (205) Clay R. Dorsey, AIA cdorsey@dorseyarchitects.com SEAL OWNER 7 PRE-TOILET ELEVATION 1/4" = 1'-0" LEFT SIDE (RIGHT SIDE SIMILAR) 6 PRE-TOILET ELEVATION 1/4" = 1'-0" FRONT 5 PRE-TOILET ELEVATION 1/4" = 1'-0" REAR CITY OF BIRMINGHAM Birmingham, Alabama PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT EXISTING PAVILLION ELEVATION EXISTING PAVILLION ELEVATIONS 4 3 1/4"= 1'-0" (TO BE RENOVATED) 1/4" = 1'-0" (TO BE RENOVATED) PROJECT IDENTIFICATION Project No Grayson Park Renovations Grayson Park 1041 Five Mile Road Birmingham, Al CONSTRUCTION DOCUMENTS PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT 1 3/16/15 ADDENDUM NO. 3 MARK DATE DESCRIPTION ISSUE DATE: 2/6/15 PROJECT NO: DRAWN BY: WGH CHECKED BY: WGH These drawings and/or specifications, and all ideas, designs, inventions, and arrangements represented thereon are and shall remain the sole and exclusive property of The Architect and no part thereof shall be copied, disclosed to others or used in connection with any other work or project other than the specified project for which they have been prepared and developed, without prior written consent of The Architect. Visual contact with these plans and /or speci- fications constitues conclcusive evidence of acceptance of these restrictions. SHEET TITLE ELEVATIONS 1 NEW PAVILLION ELEVATION - ALTERNATES # 1 & # 2 1/4 = 1'-0" FREE STANDING GRILL 8 1 1/2" = 1'-0" 2 NEW PAVILLION ELEVATION - ALTERNATES # 1 & # 2 1/4 = 1'-0" A2.1 Sheet of, Series Sheets c Copyright 2014, Dorsey Architects and Associates, Inc., st Avenue North, Suite 101 PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

38 PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT 6 A2.1 Dorsey Architects & Associates Inc st Avenue North, Suite 101 Birmingham, Alabama Ph Fax (205) (205) Clay R. Dorsey, AIA 7 A2.1 cdorsey@dorseyarchitects.com SEAL 5 A2.1 FOUNDATION PLAN 1/4" = 1'-0" 4 A2.1 OWNER 6 PRE-FAB UNISEX TOILET PLAN 1/4" = 1'-0" CITY OF BIRMINGHAM Birmingham, Alabama PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT 4 EXISTING PAVILLION ROOF PLAN 1/8" = 1'-0" (TO BE RENOVATED) 2 3 A2.1 EXISTING PAVILLION PLAN 1/8" = 1'-0" (TO BE RENOVATED) PROJECT IDENTIFICATION Project No Grayson Park Renovations Grayson Park 1041 Five Mile Road Birmingham, Al CONSTRUCTION DOCUMENTS PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT 1 3/16/15 ADDENDUM NO. 3 MARK DATE DESCRIPTION ISSUE DATE: 2/6/15 PROJECT NO: A2.1 DRAWN BY: CHECKED BY: WGH WGH Visual contact with these plans and /or speci- fications constitues conclcusive evidence of acceptance of these restrictions. These drawings and/or specifications, and all ideas, designs, inventions, and arrangements represented thereon are and shall remain the sole and exclusive property of The Architect and no part thereof shall be copied, disclosed to others or used in connection with any other work or project other than the specified project for which they have been prepared and developed, without prior written consent of The Architect. 1 A2.1 SHEET TITLE ENLARGED PLANS 5 EXISTING PLAYGROUND PLAN 1/8" = 1'-0" 3 NEW PAVILLION ROOF PLAN - ALTERNATES # 1 & # 2 1/8" = 1'-0" 1 NEW PAVILLION PLAN - ALTERNATES # 1 & # 2 1/8" = 1'-0" A1.2 Sheet of, Series Sheets c Copyright 2014, Dorsey Architects and Associates, Inc., st Avenue North, Suite 101

39 R Job No. #### File: GRAYSON PARK - ELECTRICAL.dwg Date: Mar 10, 2015 Time: 5:03:18 am Dorsey Architects & Associates Inc st Avenue North, Suite 101 Birmingham, Alabama Ph Fax (205) (205) Clay R. Dorsey, AIA cdorsey@dorseyarchitects.com SEAL A L REG I A B S T A M A ERED No PROFESSIONAL K HOS RO W E N G I N E E R R. A B D I OWNER CITY OF BIRMINGHAM Birmingham, Alabama PROJECT IDENTIFICATION Project No Alterations and Additions to Grayson Park S GRAYSON PARK. Birmingham, Al REVIEW DRAWINGS S MARK DATE DESCRIPTION ISSUE DATE: 01/15/2015 PROJECT NO: GRAYSON PARK - ELECTRICAL SCALE: 1/16" = 1'-0" S DRAWN BY: CHECKED BY: JLB KRA Visual contact with these plans and /or speci- fications constitues conclcusive evidence of acceptance of these restrictions. These drawings and/or specifications, and all ideas, designs, inventions, and arrangements represented thereon are and shall remain the sole and exclusive property of The Architect and no part thereof shall be copied, disclosed to others or used in connection with any other work or project other than the specified project for which they have been prepared and developed, without prior written consent of The Architect. SHEET TITLE ELECTRICAL SITE PLAN AND DETAILS S E102 Sheet of, Series Sheets c Copyright 2014, Dorsey Architects and Associates, Inc., st Avenue North, Suite 101

40 1.1 GENERAL CONDITIONS: ELECTRICAL SPECIFICATIONS A. THE ACCOMPANYING GENERAL CONDITIONS SHALL APPLY TO AND FORM A PART OF THIS SECTION. 1.2 CONTRACTOR QUALIFICATIONS: A. QUALIFIED ELECTRICAL CONTRACTORS SHALL HAVE BEEN IN BUSINESS AS AN ELECTRICAL CONTRACTOR FIVE (5) YEARS PRIOR TO DATE OF OPENING BIDS. EMPLOYEES OF A GENERAL CONTRACTOR WILL NOT BE ACCEPTABLE FOR THIS SECTION OF WORK. B. ALL ELECTRICAL CONTRACTORS WHOSE SUBMITTING BIDS FOR THIS PROJECT SHALL BE LICENSED AS AN ELECTRICAL SUB-CONTRACTOR IN ACCORDANCE WITH THE STATE OF ALABAMA LICENSING BOARD FOR GENERAL CONTRACTORS. C. THE ELECTRICAL CONTRACTOR SHALL USE STATE OF ALABAMA LICENSED MASTERS, JOURNEYMEN, AND APPRENTICES THAT ARE PROFESSIONAL CRAFTSMEN IN THE APPLICABLE FIELD AND PROVIDE DOCUMENTATION. A LICENSED MASTER ELECTRICIAN SHALL OBSERVE/PERFORM ALL WORK AND SHALL BE ON SITE WHEN WORK IS BEING PERFORMED. D. THE ELECTRICAL CONTRACTOR SHALL POSSESS AND PROVIDE PROOF OF INSURANCE WITH COVERAGE AND LIMITS MEETING OR EXCEEDING THOSE PRESCRIBED UNDER THE LAWS OF THE STATE OF ALABAMA FOR LIABILITY AND WORKERS' COMPENSATION. 1.3 GENERAL REQUIREMENTS: A. WORK UNDER THIS DIVISION IS SHOWN ON "E" SERIES DRAWINGS AND SPECIFIED HEREIN. DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY, INSTALL WORK CALLED FOR BY ONE AS IF CALLED FOR BY BOTH. B. OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR THIS WORK. C. ELECTRICAL WORK TO COMPLY WITH LATEST EDITION OF NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE, APPLICABLE BUILDING CODE, LOCAL ORDINANCES, AND OTHER STANDARDS INDICATED HEREIN. D. VISIT SITE TO DETERMINE WHAT EXISTING CONDITIONS AFFECT WORK, AND INCLUDE NECESSARY WORK IN BID. E. ARRANGE WITH UTILITIES AND PAY THEIR REQUIREMENTS FOR SERVICES SHOWN AND/OR SPECIFIED. F. FURNISH WRITTEN GUARANTEE TO OWNER COVERING ALL EQUIPMENT AND WORK INSTALLED THIS DIVISION FOR ONE YEAR FROM DATE OF ACCEPTANCE BY OWNER. INSTRUCT OWNER IN OPERATION OF ALL EQUIPMENT INSTALLED IN THIS DIVISION. G. ARCHITECT OR ENGINEER WILL JUDGE QUALITY OF WORKMANSHIP, INFERIOR WORK SHALL BE REDONE AND SHALL NOT BE BASIS FOR CHANGE ORDER. H. ARCHITECT OR ENGINEER WILL MAKE OBSERVATIONS OF WORK. PROVIDE LABOR AND INSTRUMENTS REQUIRED FOR THESE OBSERVATIONS AS DIRECTED BY BOTH. I. ON COMPLETION, ENTIRE WIRING SYSTEM WILL BE TESTED FOR PROPER OPERATION. J. KEEP SET OF CLEAN BLUE LINE PRINTS AT JOB SITE AND MARK ANY CHANGES IN CIRCUIT WORK, EQUIPMENT LOCATION, ETC. TURN OVER DRAWINGS TO ARCHITECT AT TIME OF FINAL OBSERVATIONS. 1.4 BASIC MATERIAL AND METHODS: A. ALL MATERIALS, EQUIPMENT, AND SYSTEMS SHALL BE NEW AND HAVE UL LABEL OR LISTING. B. BASE QUALITY AND OPERATION OF MATERIALS AND EQUIPMENT ON SPECIFIED ITEMS. INSTALL SUBSTITUTIONS FOR SPECIFIED ITEMS ONLY IF APPROVED BY ARCHITECT. C. SUBMIT SIX (6) COPIES OF SHOP DRAWINGS FOR ALL MATERIAL AND EQUIPMENT TO ARCHITECT FOR REVIEW WITHIN THIRTY (30) DAYS OF CONTRACT SIGNING. D. FURNISH AND INSTALL MATERIALS AND EQUIPMENT APPROVED EQUIVALENT TO THE FOLLOWING ITEMS: 1. RACEWAYS: a. GALVANIZED RIGID STEEL OR INTERMEDIATE GRADE STEEL CONDUIT (IMC): (1) USE FOR FEEDERS AND CIRCUITS RUN UNDERGROUND AND IN CONCRETE; CIRCUITS EXPOSED TO MECHANICAL DAMAGE OR MOISTURE. (2) TERMINATE WITH DOUBLE LOCKNUTS AND O.Z. TYPE IB BUSHINGS IN DRY LOCATIONS AND WATERTIGHT HUBS IN WET LOCATIONS. JOIN WITH THREADED FITTINGS. DO NOT SPLIT FITTINGS UNDERGROUND. b. APPROVED MANUFACTURERS STEEL CONDUIT, IMC AND EMT: R Job No. #### File: GRAYSON PARK - LEGEND.dwg Date: Mar 10, 2015 Time: 5:03:42 am Dorsey Architects & Associates Inc st Avenue North, Suite 101 Birmingham, Alabama Ph Fax (205) (205) Clay R. Dorsey, AIA cdorsey@dorseyarchitects.com A L SEAL REG I A B S T A M A ERED No PROFESSIONAL K HOS RO W E N G I N E E R R. OWNER A B D I CITY OF BIRMINGHAM Birmingham, Alabama + (1) TRIANGLE; SOUTHWIRE; ETP; REPUBLIC; WHEATLAND. c. PVC CONDUIT, SCHEDULE 40; CARLON; SEDCO OR APPROVED EQUAL. JOIN AND TERMINATE WITH SOLVENT TYPE FITTINGS. USE PVC CONDUIT; UNDERGROUND WHERE SHOWN ON DRAWINGS. 2. OUTLET BOXES TO CONFORM TO UL STANDARD NO. 5L4, CONSTRUCTED OF SHEET STEEL, 4" SQUARE X DEPTH AS REQUIRED FOR WALL OUTLETS AND 4" OCTAGONAL X DEPTH AS REQUIRED FOR CEILING OUTLETS. PROVIDE NECESSARY PLASTER FRAMES. USE SQUARE CUT OUTLET BOXES WITHOUT KNOCKOUTS TO GIVE FINISHED APPEARANCE IN EXPOSED WORK, WIREMOLD OR EQUAL. 3. CONSTRUCT PULL AND JUNCTION BOXES PER NEMA STANDARDS; SIZE PER NATIONAL ELECTRICAL CODE; GALVANIZED FINISH WITH SCREW COVERS, 14 GAGE STEEL MINIMUM. PROVIDE GASKETED COVER FOR WEATHERPROOF BOXES. 4. CONDUCTORS TO CONSIST OF 98% CONDUCTIVITY COPPER, #10 AWG AND SMALLER - SOLID, #8 AWG AND LARGER - STRANDED, WITH NEC 600 VOLT TYPE THW, THWN, XHHW OR APPROVED EQUIVALENT. 100 AMP FEED AND LARGER MAY BE ALUMINUM IF TERMINATED WITH COMPRESSION FITTINGS. 5. PROVIDE COVERS ON OUTLETS. USE GALVANIZED STEEL COVERS IN UNFINISHED AREAS. USE.04" THICK TYPE 302 STAINLESS STEEL DEVICE PLATES IN FINISHED AREAS, SIERRA, OR APPROVED EQUIVALENT. 6. FEEDER PANEL DEAD FRONT WITH LOCKABLE DOOR; BUSSING - 98% CONDUCTIVITY COPPER OR 61% CONDUCTIVITY ALUMINUM SIZED ON 65 DEGREES C TEMPERATURE RISE ABOVE 40 DEGREES C. AMBIENT. CONVERTIBLE CIRCUIT BREAKER TYPE, CONSTRUCTED IN ACCORDANCE WITH APPLICABLE NEMA STANDARDS; STANDARD PRODUCT OF SIEMENS, SQUARE "D", GENERAL ELECTRIC, OR CUTLER-HAMMER. BREAKERS WITH AIC RATING AS INDICATED ON PLANS AT HIGHEST INCOMING VOLTAGE; NAMEPLATE CIRCUIT. POLE BASE DETAIL NOT TO SCALE PROJECT IDENTIFICATION Project No Alterations and Additions to Grayson Park GRAYSON PARK. Birmingham, Al REVIEW DRAWINGS 1.5 TYPE OF INSTALLATION: A. RUN CIRCUITS IN CONDUIT, TYPE AS DESCRIBED ABOVE FOR SPECIFIC LOCATIONS. B. CONNECT WIRING COMPLETE. INSTALL WIRING CABINETS, PANELS, ETC., NEATLY. SPLICE CONDUCTORS #10 AWG AND SMALLER WITH SCREW-ON, SOLDERLESS, INSULATED CONNECTORS, 3M "SCOTCHLOCK" OR EQUIVALENT. SPLICE CONDUCTORS #8 AWG AND LARGER WITH COPPER ALLOY, BOLTED CONNECTORS, "VERSALINK" OR "VERSATAP" AS REQUIRED. WRAP SPLICES AND TAPS WITH RUBBER AND ELECTRICAL TAPE TO INSULATE TO 600 VOLTS. COLOR CODE CONDUCTORS BLACK, RED, BLUE, WHITE, AND GREEN. C. BOND AND GROUND CABINETS, ENCLOSURES, NEUTRAL, ETC., AS REQUIRED BY NATIONAL ELECTRICAL CODE. USE CONDUCTORS SIMILAR TO POWER WIRING DESCRIBED ABOVE. MAKE CONNECTIONS WITH COPPER ALLOY OR BRONZE CONNECTORS, BURNDY OR EQUIVALENT. USE BOLTED OR SCREW-ON TYPE CONNECTIONS. COAT GROUND CONNECTIONS BETWEEN DISSIMILAR METALS WITH EPOXY RESIN SEALER. INSTALL GROUND WIRE IN CIRCUITS INDICATED AND BOND TO ALL CABINETS, BOXES, DEVICES, ETC. INSTALL GROUND CONDUCTOR PER NEC IN PVC CONDUIT. D. EXCAVATE AND BACKFILL FOR WORK IN THE DIVISION. AVOID EXISTING UNDERGROUND UTILITIES. REPAIR IF DAMAGED. REPAIR WORK CUT COMPARABLE TO ADJACENT CONDITION, INCLUDING NEW SOD, SHRUBBERY, PAVING, ETC. ARCHITECT WILL JUDGE REPAIR WORK. E. PROVIDE POWER TO ALL ITEMS REQUIRING ELECTRICAL CONNECTIONS WHETHER SHOWN ON ELECTRICAL DRAWINGS OR NOT. CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS, VERIFY, AND PROVIDE: 1. PROPER ELECTRICAL CONNECTIONS FURNISHED. a. VOLTAGE b. AMPACITY c. CONNECTIONS TO FIRE ALARM AS REQUIRED BY CODE. 1.6 SERVICE REQUIREMENTS: A. VERIFY SERVICE REQUIREMENTS AND LOCATION WITH UTILITY COMPANY. ADJUST THAT SHOWN TO FIT THEIR REQUIREMENTS. B. PROVIDE ALL ITEMS REQUIRED BY UTILITY COMPANY FOR SERVICE SHOWN INCLUDING LOAD DATA. C. VERIFY AVAILABLE SHORT CIRCUIT CORRECT WITH UTILITY COMPANY AND PROVIDE ELECTRICAL SERVICE AND DISTRIBUTION COMPONENTS TO HANDLE AND INTERRUPT SAME. D. VERIFY REQUIREMENTS FOR TELEPHONE AND CABLE SERVICE AND FURNISH REQUIRED COMPONENTS. 1.7 LUMINAIRES: A. SUPPORT LUMINAIRES FROM STRUCTURAL MEMBERS OF BUILDING, INDEPENDENT OF CEILING. SUPPORT GRID TYPE LUMINAIRES AT ALL FOUR (4) CORNERS OF (1' X 4' AND 2' X 4') FIXTURES TO STRUCTURE. EARTHQUAKE CLIPS ALONE WILL NOT BE ACCEPTABLE. B. VERIFY VOLTAGE REQUIRED FROM PLANS. C. FLUORESCENT BALLAST SHALL BE ELECTRONIC. D. LINEAR FLUORESCENT LAMPS SHALL BE T-8 TYPE. 1.8 CODE COMPLIANCE: A. ALL ELECTRICAL SYSTEMS SHALL BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE CODES. THIS SPECIFICALLY COVERS: 1. INSTALLING EQUIPMENT TO MEET CODE CLEARANCES (ADJUST EQUIPMENT AS REQUIRED, NOTIFYING ENGINEER FOR APPROVAL OR SUBMITTING SKETCH). 2. VERIFYING AND RESPECTING CLEARANCES OF OTHER COMPONENTS, HVAC, PLUMBING, ETC. 3. MEETING ALL LOCAL INTERPRETATIONS OF CODES. B. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR COMPLIANCE WITH MEETING CODES. MARK DATE ISSUE DATE: 01/15/2015 PROJECT NO: DRAWN BY: CHECKED BY: JLB KRA Visual contact with these plans and /or speci- fications constitues conclcusive evidence of acceptance of these restrictions. These drawings and/or specifications, and all ideas, designs, inventions, and arrangements represented thereon are and shall remain the sole and exclusive property of The Architect and no part thereof shall be copied, disclosed to others or used in connection with any other work or project other than the specified project for which they have been prepared and developed, without prior written consent of The Architect. SHEET TITLE DESCRIPTION ELECTRICAL LEGEND AND DETAILS E101 Sheet of, Series Sheets c Copyright 2014, Dorsey Architects and Associates, Inc., st Avenue North, Suite 101

PLAN SUBMITTAL REQUIREMENTS

PLAN SUBMITTAL REQUIREMENTS DEPARTMENT OF ECONOMIC AND COMMUNITY DEVELOPMENT BUILDING DIVISION PLAN SUBMITTAL REQUIREMENTS Residential and Commercial Projects Welcome to the South San Francisco Building Division. We are providing

More information

SECTION BUILDING WIRE AND CABLE

SECTION BUILDING WIRE AND CABLE SECTION 260519 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Building wire and cable. 2. Wiring connectors and connections. B. RELATED SECTIONS 1. Section 26 05 53 Electrical Identification. 2. Section

More information

A. Deviation from this standard must be approved by the Project Architect.

A. Deviation from this standard must be approved by the Project Architect. September 2012, rev. 00 26 5600 Exterior Lighting PART 1. GENERAL 1.01 Related Documents A. Deviation from this standard must be approved by the Project Architect. B. Drawings and general provisions of

More information

Page Electric Utility Service Specifications

Page Electric Utility Service Specifications T Y P I C A L U N D E R G R O U N D S E R V I C E R E Q U I R E M E N T S 200 Amps Maximum - UG-1 Sheet 1 of 3 87 T Y P I C A L U N D E R G R O U N D S E R V I C E R E Q U I R E M E N T S 200 Amps Maximum

More information

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. SECTION 26 05 19 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. 1.2 CONTRACTOR SUBMITTALS A. The

More information

SECTION PANELBOARDS

SECTION PANELBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section

More information

St. Monica Food Pantry

St. Monica Food Pantry St. Monica Food Pantry 26 5113-1 ELECTRICAL WORK DIVISION 26 SECTION 265113 INTERIOR LIGHTING FIXTURES PART 1. GENERAL 1.1 WORK INCLUDES A. Extent, location, and details of interior lighting fixture work

More information

Article 225: Outside Branch Circuits And Feeders

Article 225: Outside Branch Circuits And Feeders Part C: Code Book Questions Article 225: Outside Branch Circuits And Feeders 1.! Open (individual) aerial overhead conductors shall be insulated or covered when within! feet of a building.! (a) 10! (c)

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions conduit? 9/8/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Can branch circuits of different services be installed in the same Yes, see 300.3(C)(1) for conductors of different systems

More information

CONTINUING EDUC ATION

CONTINUING EDUC ATION 3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com

More information

DIVISION 26 ELECTRICAL SECTION ELECTRICAL

DIVISION 26 ELECTRICAL SECTION ELECTRICAL DIVISION 26 ELECTRICAL SECTION 26 1000 ELECTRICAL PART 1 - GENERAL 1.1 WORK INCLUDED A. Furnish all labor, material and equipment necessary for the complete installation of the Electrical System as shown

More information

COVER SHEET A0.1 A0.1 COVER SHEET A1.1 FLOOR PLANS - FOUNDATION & MAIN LEVEL A1.2 FLOOR PLANS - UPPER LEVEL & ROOF A3.1 SECTIONS & INTERIOR ELEVATIONS

COVER SHEET A0.1 A0.1 COVER SHEET A1.1 FLOOR PLANS - FOUNDATION & MAIN LEVEL A1.2 FLOOR PLANS - UPPER LEVEL & ROOF A3.1 SECTIONS & INTERIOR ELEVATIONS TWO-STORY DUPLEX UNIT ONE (WILLOW): THREE BEDROOM, TWO BATH UNIT TWO (FIR): TWO BEDROOMS, ONE AND ONE-HALF BATH - 2012 INTERNATIONAL RESIDENTIAL CODE - CITY OF BRECKENRIDGE MUNICIPLE CODE 1. ALL WORK SHALL

More information

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. a.

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO PAGE PROJECT NO. 0-0 0 0 0 0 0 DATE: PROJECT: GATEWAY STEM ATHLETICE FIELD ALTERATIONS GATEWAY STEM HIGH SCHOOL - ST. LOUIS PUBLIC SCHOOLS 0 MCRTEE AVENUE ST. LOUIS, MISSOURI 0 TO BID DOCUMENTS DATED DECEMBER,

More information

Residential Construction Checklist Single and Two Family Construction

Residential Construction Checklist Single and Two Family Construction DATE: _ Building Inspection Submittal Requirements Residential Construction Checklist Single and Two Family Construction Submit a City of Big Spring Permit Application, checklist, and 3 complete hard copy

More information

Single-Family Dwelling Submittal Requirements

Single-Family Dwelling Submittal Requirements Single-Family Dwelling Submittal Requirements The purpose of this guideline is to assist our customers in preparing for plan submittal. The items listed must be included before your plans can be accepted

More information

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

.1 Applicability: These criteria shall be applied as follows:

.1 Applicability: These criteria shall be applied as follows: DESIGN CRITERIA DIVISION 4800 STREET LIGHTING 4801 GENERAL: These criteria shall be adhered to for the design of all publiclyfinanced or privately-financed traffic signal systems to be installed in the

More information

A. Product Description: Stranded conductor insulated wire.

A. Product Description: Stranded conductor insulated wire. SECTION 16120CPPR CONDUCTORS AND CABLE PART 1 - GENERAL 1.1 SYSTEM DESCRIPTION A. Product Requirements: Provide products as follows: 1. All building wire shall be stranded copper (no aluminum wire). 2.

More information

SECTION CABLE TRAYS

SECTION CABLE TRAYS SECTION 16139 CABLE TRAYS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

POWER SERVICE DETAILS

POWER SERVICE DETAILS POWER SOURCE # POLE MOUNTED SERVICE TRANSFORMER BY POWER HANDHOLE 0/0V, -PHASE, SERVICE CONDUCTORS; -# AWG SERVICE CONDUCTOR AND -# AWG GROUNDED SERVICE CONDUCTOR (NEUTRAL) SERVICE XFMR SECONDARY. A 0V

More information

Notre Dame High Addition/Renovation Addendum 3 Page 1

Notre Dame High Addition/Renovation Addendum 3 Page 1 School Notre Dame High Addition/Renovation Addendum 3 Page 1 PROJECT: Notre Dame High School Addition/ Renovation Calgary. Alberta DATE November 15, 2012 ADDENDUM NO. 3 Attachment pages Addendum: Page(s)

More information

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION SECTION 16715 COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION PART 1 - GENERAL 1.01 SECTION DESCRIPTION AND BASIC REQUIREMENTS A. The Electrical Power Distribution System provides power distribution from

More information

ADDENDUM #1. April 29, 2009

ADDENDUM #1. April 29, 2009 April 29, 2009 Re: HACC, Central Pennsylvania s Community College Midtown 1 CCTA Phase 2 Solicitation # 09-17 From: Eastern pcm, LLC Construction Manager HACC 212 Locust Street, Suite 604 Harrisburg, PA

More information

SECTION EQUIPMENT WIRING

SECTION EQUIPMENT WIRING PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 26 27 17 EQUIPMENT WIRING A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General Provisions,

More information

HAMMEL ASSOCIATES ARCHITECTS, LLC 2 5 E A S T G R A N T S T R E E T, S U I T E L A N C A S T E R, P E N N S Y L V A N I A

HAMMEL ASSOCIATES ARCHITECTS, LLC 2 5 E A S T G R A N T S T R E E T, S U I T E L A N C A S T E R, P E N N S Y L V A N I A CHL ASSOCIATES ARCHITECTURE 1 5 7 0 R I V E R R O A D, M A R I E T T A, P E N N S Y L V A N I A 1 7 5 4 7 HAMMEL ASSOCIATES ARCHITECTS, LLC 2 5 E A S T G R A N T S T R E E T, S U I T E 1 0 2 L A N C A

More information

Spec Section: , Complete Elec, Comm, and Fire Alarm , Complete Elec, Comm, and Fire Alarm Data Sheets RAN/GCAN

Spec Section: , Complete Elec, Comm, and Fire Alarm , Complete Elec, Comm, and Fire Alarm Data Sheets RAN/GCAN SUBMITTAL REVIEW Submittal: No. 019.00 Spec Section: 26 0000, 28 0000 Complete Elec, Comm, and Fire Alarm Reviewed By: Laura Landon, Comma-Q Architecture Date: June 29, 2012 Project: BPS Belgrade Elementary

More information

Addendum. Windsor Hall Renovations Date: October 12, 2017 Addendum No: 3 GENERAL. 1! Addendum #4 will be issued 2:00 PM Tuesday October 17, 2017.

Addendum. Windsor Hall Renovations Date: October 12, 2017 Addendum No: 3 GENERAL. 1! Addendum #4 will be issued 2:00 PM Tuesday October 17, 2017. !!! Addendum EXP Project No: MTA Project No: WIND-17-01 Project: Windsor Hall Renovations October 12, 2017 Addendum No: 3 The following information supplements and/or supersedes the bid documents. This

More information

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING 1 1 1 1 1 NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING NORTH CAROLINA BUILDING CODE COUNCIL Notice of Rule-making Proceedings is hereby given by NC Building Code Council in accordance with G.S.

More information

ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL

ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL BELL SYSTEM PRACTICES Plant Series SECTION 508-100-100 Issue 3, October 1970 AT&TCo Standard ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL I. GENERAL 1.01 This section is reissued to: Revise

More information

SPECIAL SPECIFICATION LIGHTNING PROTECTION SYSTEM

SPECIAL SPECIFICATION LIGHTNING PROTECTION SYSTEM 2004 Specifications CSJ 3622-01-001, ETC. SPECIAL SPECIFICATION 8398 LIGHTNING PROTECTION SYSTEM 1. Description. This Special Specification governs the design and installation of Lightning Protection System

More information

SECTION IDENTIFICATION FOR ELECTRONIC SAFETY AND SECURITY

SECTION IDENTIFICATION FOR ELECTRONIC SAFETY AND SECURITY SECTION 280553-IDENTIFICATION FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 DESCRIPTION A. This specification section covers the furnishing and installation of nameplates, labels, wire markers,

More information

City of Lompoc Building & Safety Services Section 100 Civic Center Plaza Lompoc, CA Phone: Fax:

City of Lompoc Building & Safety Services Section 100 Civic Center Plaza Lompoc, CA Phone: Fax: City of Lompoc Building & Safety Services Section 100 Civic Center Plaza Lompoc, CA 93436 Phone: 805-875-8220 Fax: 805-875-8198 RESIDENTIAL BUILDING PLANS SUBMITTAL REQUIREMENTS A. APPLICATION PROCESS

More information

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868) WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868) THREE-PHASE SUBSURFACE UNDERGROUND COMMERCIAL DISTRIBUTION (UCD) TRANSFORMER NOTE: This "Guide" summarizes the opinions, recommendations, and practices

More information

ELPT 1429 RESIDENTIAL WIRING

ELPT 1429 RESIDENTIAL WIRING SYLLABUS ELPT 1429 RESIDENTIAL WIRING INDUSTRIAL AND COMMERCIAL ELECTRICITY BRAZOSPORT COLLEGE LAKE JACKSON TEXAS PREPARED BY: Larry Grable DATE: September 13, 2005 INSTRUCTOR RECOMMENDED BY: RECOMMENDED

More information

B. Manufacturers: Square-D, G.E. or Westinghosue.

B. Manufacturers: Square-D, G.E. or Westinghosue. SECTION 16470 - PANELBOARDS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

ADDENDUM NO. 3 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030

ADDENDUM NO. 3 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030 ADDENDUM NO. 3 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO. 2018-008-COM.00030 To: Prospective Bidders of Record Date: January 8, 2019 The following changes, additions, revisions, and/or deletions

More information

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP 1 1 1 0 1 0 1 0 1 SECTION 1 1 CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP BASED ON DFD MASTER SPECIFICATION DATED /01/ P A R T 1 - G E N E R A L SCOPE The work under this section shall consist of

More information

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEM(S) FOR STREETLIGHTS. 1 Definitions. 2 Scope of Work. 3 Extent of Work

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEM(S) FOR STREETLIGHTS. 1 Definitions. 2 Scope of Work. 3 Extent of Work SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEM(S) FOR STREETLIGHTS Section 1 Definitions 2 Scope of Work 3 Extent of Work 4 Inspection and Performance of Work 5 Trenching 6 Duct Installation 7 Backfilling

More information

BIRMINGHAM CITY SCHOOLS (BCS) OPERATIONAL CENTER COMPLEX: BID PACKAGE D

BIRMINGHAM CITY SCHOOLS (BCS) OPERATIONAL CENTER COMPLEX: BID PACKAGE D HOSKINS ARCHITECTURE, LLC 1721 4 th AVENUE NORTH, SUITE 101 BIRMINGHAM, ALABAMA 35203 205.321.4122 ADDENDUM NO. 7 PROJECT: BIRMINGHAM CITY SCHOOLS (BCS) OPERATIONAL CENTER COMPLEX: BID PACKAGE D HOSKINS

More information

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form. McKee and Associates Architecture and Interior Design Addendum No. THREE Date: 12.11.17 Project: A NEW BUILDING FOR THE GREATER LIMESTONE COUNTY CHAMBER OF COMMERCE ATHENS, ALABAMA A3.1 GENERAL PROJECT

More information

Electrical IP Red Seal Practice Exam

Electrical IP Red Seal Practice Exam Electrical IP Red Seal Practice Exam PRACTICE EXAM-3 1. What size 2 pole breaker must you use on a 3HP, 115V single phase motor? A. 40A B. 50A C. 80A. D. 100A. 2. An electrical equipment approved for use

More information

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No St. Monica Food Pantry 26 0519-1 ELECTRICAL WORK DIVISION 26 SECTION 260519 LOW VOLTAGE (600V AND LESS) PART 1. GENERAL 1.1 WIRES (SINGLE CONDUCTOR) AND CABLES (MULTI-CONDUCTOR ASSEMBLIES) USED FOR THE

More information

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION! PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling

More information

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations. General Conditions: 1. Deliver all food service equipment as specified herein, including that which is reasonably inferred, with all related items necessary to complete work shown on contract drawings

More information

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33 Part VIII Electrical CHAPTER 33 GENERAL REQUIREMENTS < SECTION E3301 GENERAL E3301.1 Scope. The installation of electrical systems, equipment and components indoors and outdoors that are within the scope

More information

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

ADDENDUM No. 4 Page 1 of 8 (includes attachment)

ADDENDUM No. 4 Page 1 of 8 (includes attachment) ADDENDUM No. 4 Page 1 of 8 (includes attachment) Date Issued: November 27, 2017 Project: TOWNSHIP OF NORWICH FIRE SERVICE STATION No: 3 BURGESSVILLE, ONTARIO 385435 HIGHWAY 59, BUGESSVILLE, ONTARIO N0J

More information

Regal Series Recessed Flatwalls

Regal Series Recessed Flatwalls Regal Series Recessed Flatwalls General Specifications The Amico Regal Series Recessed Flatwall shall be manufactured by Amico Corporation, in accordance with job specific shop drawings and documents.

More information

Addendum No. 1 page 1

Addendum No. 1 page 1 Addendum No. 1 page 1 Project: Proj. No: 1634.02 Scottsburg High School HVAC Renovation 2017 Scott County School District 2 Scottsburg, Indiana Date: November 22, 2016 This addendum is a part of the bid

More information

1. This Section specifies the ethernet Category 5E data cabling system for buildings and structures.

1. This Section specifies the ethernet Category 5E data cabling system for buildings and structures. PAGE 271200-1 SECTION 271200 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION LIGHTING

SECTION LIGHTING SECTION 16500 - LIGHTING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

FAB GSE Remodel ITB Solicitation #1538 Invitation to Bid (ITB) for General Contracting Services. ADDENDUM #4 December 5, 2014

FAB GSE Remodel ITB Solicitation #1538 Invitation to Bid (ITB) for General Contracting Services. ADDENDUM #4 December 5, 2014 FAB GSE Remodel ITB Solicitation #1538 Invitation to Bid (ITB) for General Contracting Services ADDENDUM #4 December 5, 2014 This Addendum is issued to provide answers to questions from potential bidders

More information

SECTION SUBMITTALS. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION SUBMITTALS. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 013300 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

Series 5 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets

Series 5 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets Eaton's Crouse-Hinds Series 5 die cast copper-free aluminum conduit bodies, covers and gaskets are available for use with rigid or EMT conduit (with set screw). Conduit bodies are available in trade sizes

More information

HOENER ASSOCIATES INC. ARCHITECTS

HOENER ASSOCIATES INC. ARCHITECTS HOENER ASSOCIATES INC. ARCHITECTS BRUCE D. DELL MARK REUTHER ADDENDUM NO. 1 PROJECT 15-22C RENOVATION AND SITE WORK AT: BUILDING B DDRB OF ST. CHARLES DEVELOPMENT DISABILITIES RESOURCE BOARD ST. CHARLES,

More information

Quality Control Checklist - Design Drawings

Quality Control Checklist - Design Drawings Quality Control Checklist - Design Drawings Date Company Name Address Telephone Fax Email Job Number 1) Drawing Set a) Drawing one is site/location/incoming power i) Should contain location map if not

More information

PORT OF ST. HELENS SCAPPOOSE INDUSTRIAL AIRPARK PARALLEL TAXIWAY B RELOCATON AIP PROJECT ADDENDUM NO. 1

PORT OF ST. HELENS SCAPPOOSE INDUSTRIAL AIRPARK PARALLEL TAXIWAY B RELOCATON AIP PROJECT ADDENDUM NO. 1 PORT OF ST. HELENS SCAPPOOSE INDUSTRIAL AIRPARK PARALLEL TAXIWAY B RELOCATON AIP PROJECT 3-41-0056-024-2018 ADDENDUM NO. 1 Addendum No. 1 hereby amends the contract documents and drawings for the Scappoose

More information

Section. DEVELOPMENT STANDARDS City of Ellensburg ILLUMINATION STANDARDS

Section. DEVELOPMENT STANDARDS City of Ellensburg ILLUMINATION STANDARDS Section 8 City of Ellensburg ILLUMINATION STANDARDS Table of Contents STREET ILLUMINATION...3-5 GENERAL NOTES...3 INSTALLATION AND CONNECTIONS...3 MARKING...3 STAKING...3-4 TRENCH REQUIREMENTS...4 ILLUMINATION

More information

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit Current will always try to return to its source In order for there to be current, there must be a complete circuit Current will take as many paths or circuits available to it to return to the source The

More information

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval Redwood City Electric, Inc. TRANSMITTAL LETTER To: Transworld Construction, Inc. 1178 Folsom Street San Francisco, CA 94103 Date: 05/31/12 Job #: 9340 Regarding: SFO DATA CENTER Attn: Rob Acero We are

More information

BUILDING PLANS. BUILDING INSPECTIONS DEPARTMENT

BUILDING PLANS. BUILDING INSPECTIONS DEPARTMENT BUILDING PLANS BUILDING INSPECTIONS DEPARTMENT 507-537-6773 www.ci.marshall.mn.us This handout is intended only as a guide to the subject matter covered herein and is based in part on the 2015 Minnesota

More information

Item 550 Chain Link Fence

Item 550 Chain Link Fence Item Chain Link Fence 1. DESCRIPTION 2. MATERIALS Furnish, install, remove, repair, or replace chain link fence and gates. Furnish certification from the chain link fence materials manufacturer stating

More information

CITY OF LOVELAND HOMEOWNERS GUIDE FOR BUILDING PERMITS FOR HOME IMPROVEMENTS

CITY OF LOVELAND HOMEOWNERS GUIDE FOR BUILDING PERMITS FOR HOME IMPROVEMENTS CITY OF LOVELAND HOMEOWNERS GUIDE FOR BUILDING PERMITS FOR HOME IMPROVEMENTS Development Services Department Building Division 500 East Third Street, Suite 110 Loveland, CO 80537 (970) 962-2505 FAX (970)

More information

TRIBAL BUILDING AND DEVELOPMENT Plan Check Submittal

TRIBAL BUILDING AND DEVELOPMENT Plan Check Submittal TRIBAL BUILDING AND DEVELOPMENT Plan Check Submittal Complete sets of plans are required. Plans shall be stamped and wet signed by the architect or engineer. (signed and accompanied with letter from Homeowners

More information

City of Thousand Oaks

City of Thousand Oaks TENANT IMPROVEMENT SUBMITTAL CHECKLIST SUBMIT THREE SETS OF SCALED DRAWINGS (ONE TO BE A BLACKLINE SET) WITH THE FOLLOWING INFORMATION: 1. 2. 3. 4. 5. 6. 7. 8. 9. SITE PLAN: Show building location (vicinity

More information

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5 Applied Grounding and Bonding Paul Dobrowsky Member NEC Panel 5 1 Introduction This presentation is a representative sample from the following Chapters of Applied Grounding and Bonding. Chapter 1, Introduction

More information

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 36 WIREWAYS FOR RADIOLOGY EQUIPMENT SPEC WRITER NOTE: Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable

More information

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS. Notification of Completed Conduit Sections

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS. Notification of Completed Conduit Sections SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS Section 1 Definitions 2 Scope of Work 3 Extent of Work 4 Inspection and Performance of Work 5 Trenching 6 Duct Installation

More information

A. Product Data: For each electrical identification product indicated.

A. Product Data: For each electrical identification product indicated. SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

ADDENDUM #2 September 12, 2018

ADDENDUM #2 September 12, 2018 Physical Plant Services Project Management 1000 Rim Drive Phone: (970) 247-7523 Fax: (970) 247-7555 Project No. 2007-130P18 Whalen Gymnasium Expansion and Renovation for Exercise Science Request for Qualifications

More information

SECTION DISTRIBUTION SWITCHBOARDS

SECTION DISTRIBUTION SWITCHBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 11 SPEC WRITER NOTES: Use this section only for NCA projects. Delete between // -- // if not applicable to project. Also delete any other item or paragraph

More information

SIGN CRITERIA CONSER CROSSING MAJOR TENANTS

SIGN CRITERIA CONSER CROSSING MAJOR TENANTS SIGN CRITERIA CONSER CROSSING LOCATION: ZONING DISTRICT: Southeast Corner of 151 st & Conser Street MXD EFFECTIVE DATE: August 1, 2006 MAJOR TENANTS Major Tenants A, B, C and D as shown of Figure 1, Site

More information

SECTION TRANSFORMERS

SECTION TRANSFORMERS SECTION 16460 - TRANSFORMERS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Section

More information

DOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410

DOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410 DOCUMENT 009104 - ADDENDUM NO. 4 Issued to all Bidders: Date: October 14, 2015 Contract Name: Electrical Installation Contract Number: C8410 This addendum forms a part of the Bid described above. The original

More information

METER - INSTALLATION Pad Mount Transformer

METER - INSTALLATION Pad Mount Transformer ER 1-210-C PAGE 1 OF 5 USE: Pad mount transformer secondary compartment LATEST REVISION: PREVIOUS REVISION 10-01-12 ORIGINATED 0-94 PREVIOUS NUMBER ER 700, 10-01-86 Added specification for placement and

More information

FIRE STATION NO TH STREET NORTH ST. PETERSBURG, FL M-1 SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC SYMBOL LEGEND

FIRE STATION NO TH STREET NORTH ST. PETERSBURG, FL M-1 SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC SYMBOL LEGEND HVAC SYMBOL LEGEND HVAC PIPING AND VALVES LEGEND HVAC GENERAL NOTES SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION PHASING OF WORK HVAC ABBREVIATIONS ABBREVIATION

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I have a 500 KVA generator, with no overcurrent protection

More information

Chapter 25. Lighting Plans

Chapter 25. Lighting Plans Chapter 25 Lighting Plans The following are changes, additions or deletions to the January 2014, Topic #625-000-008, Plans Preparation Manual (PPM), for use on Turnpike projects only. 25.1 General Replace

More information

BUILDING PLANS. BUILDING DEPARTMENT

BUILDING PLANS. BUILDING DEPARTMENT BUILDING PLANS BUILDING DEPARTMENT 952-446-1660 www.cityofminnetrista.com This handout is intended only as a guide and is based in part on the 2015 Minnesota Residential Code, Minnetrista City ordinances,

More information

TELEPHONE: (215) Addendum No New Solomon Solis-Cohen Elementary School SDP Contracts No. B-075C, B-076C, B-077C and B-078C of 2017/18

TELEPHONE: (215) Addendum No New Solomon Solis-Cohen Elementary School SDP Contracts No. B-075C, B-076C, B-077C and B-078C of 2017/18 THE SCHOOL DISTRICT OF PHILADELPHIA SCHOOL REFORM COMMISSION Office of Capital Programs 440 North Broad Street, 3 rd Floor Suite 371 Philadelphia, PA 19130 TELEPHONE: (215) 400-4730 Addendum No. 003 Subject:

More information

American Electrical Institute

American Electrical Institute American Electrical Institute Oregon Electricians Continuing Education Grounding & Bonding (Article 250) 4 Hours American Electrical Institute PO Box 31131 Spokane, WA 99223 www.aeitraining.com Article

More information

SECTION DISTRIBUTION SWITCHBOARDS

SECTION DISTRIBUTION SWITCHBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 13 DISTRIBUTION SWITCHBOARDS SPEC WRITER NOTE: Delete between // -- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

ADDENDUM NO. 3. Ellis County Elections Building

ADDENDUM NO. 3. Ellis County Elections Building AUSTIN ARCHITEXAS DALLAS ARCHITECTURE, PLANNING AND HISTORIC PRESERVATION, INC. ADDENDUM NO. December 8, 2014 to the BIDDING DOCUMENTS for Ellis County Elections Building Waxahachie, Texas By ARCHITEXAS

More information

StormTrap Guide Specification. StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18

StormTrap Guide Specification. StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18 StormTrap Guide Specification StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18 This product guide specification is written according to the Construction Specifications Institute

More information

ZIP CLOUD SUSPENDED INSTALLATION MANUAL

ZIP CLOUD SUSPENDED INSTALLATION MANUAL ZIP CLOUD SUSPENDED INSTALLATION MANUAL www.delviro.com info@delviro.com 1.877.502.3434 SAFETY NOTE: Follow the Electrical Codes of the Country where this fixture will be installed. For Canada follow the

More information

Wisconsin Contractors Institute Continuing Education

Wisconsin Contractors Institute Continuing Education IMPORTANT NOTE: You should have received an email from us with a link and password to take your final exam online. Please check your email for this link. Be sure to check your spam folder as well. If you

More information

SECTION ELECTRICAL IDENTIFICATION

SECTION ELECTRICAL IDENTIFICATION SECTION 16075 ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples... SECTION E INDEX Product Description Page Number Conduit End Bells.......................................EA Hex Reducing Bushings..................................EA2 Conduit Hubs......................................EA-EA4

More information

TELEPHONE: (215) Addendum No. 1

TELEPHONE: (215) Addendum No. 1 THE SCHOOL DISTRICT OF PHILADELPHIA SCHOOL REFORM COMMISSION Office of Capital Programs 440 North Broad Street, Third Floor - Suite 371 Philadelphia, PA 19130-4015 TELEPHONE: (215) 400-4730 Addendum No.

More information

COMMERCIAL ITEM DESCRIPTION SPLICE CONNECTORS

COMMERCIAL ITEM DESCRIPTION SPLICE CONNECTORS INCH-POUND A-A-59213A 28 May 2009 SUPERSEDING A-A-59213 18 May 1998 COMMERCIAL ITEM DESCRIPTION SPLICE CONNECTORS The General Services Administration has authorized the use of this commercial item description

More information

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT A. General In a hazardous location grounding of an electrical power system and bonding of enclosures of circuits and electrical equipment in the

More information

KidsAbility Guelph Hub Renovation ADDENDUM #2 Project No.:

KidsAbility Guelph Hub Renovation ADDENDUM #2 Project No.: KidsAbility Guelph Hub Renovation ADDENDUM #2 This Addendum amends and forms part of the Bidding and Contract Documents for the above Project as follows: CLARIFICATIONS Q1. Is it possible to set up a secondary

More information

INDIGO LAKES HOA ARCHITECTURAL REVIEW COMMITTEE REQUEST FOR MODIFICATION

INDIGO LAKES HOA ARCHITECTURAL REVIEW COMMITTEE REQUEST FOR MODIFICATION INDIGO LAKES HOA ARCHITECTURAL REVIEW COMMITTEE REQUEST FOR MODIFICATION I/We hereby request approval by the Architectural Review Committee for the modification shown below of Lot #: Street Address: Phone

More information

HP 2 SERIES Integral Driver - Solid State LED

HP 2 SERIES Integral Driver - Solid State LED HP 2 SERIES Installation Instructions Warning High Voltage Hot Surface NEEDED FOR INSTALLATION: By Others 1/8 & 5/32 Allen Wrench Waterproof Wire Connectors Level Phillips Screwdriver IMPORTANT - WEAR

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION PART 1 GENERAL 1.01 SUMMARY Section 16195 A. This Section includes electrical identification for the following: 1. Nameplates and labels 2. Wire and cable markers 3. Conduit markers 4. Cable tray markers

More information

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16 QuadroMAX LED Outdoor Lighting Fixtures Installation Manual QM Series REV: 3/22/16 BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING Risk of fire or electric shock. Luminaire wiring

More information

For crossing under a railroad, contact the specific railroad company's engineering department.

For crossing under a railroad, contact the specific railroad company's engineering department. PAGE 330524-1 SECTION 330524 SPECIFIER: This section is for the underground installation of piping by directional drilling. When specifying this method of piping installation, care must be taken to ensure

More information

UNION COUNTY ENGINEER DIVISION OF BUILDING REGULATIONS

UNION COUNTY ENGINEER DIVISION OF BUILDING REGULATIONS UNION COUNTY ENGINEER DIVISION OF BUILDING REGULATIONS Residential Pool Permit Requirements FEES: A nonrefundable permit application fee of $25.25 and a nonrefundable plan review fee of $40.40 will be

More information