Facility Pipe Marking

Size: px
Start display at page:

Download "Facility Pipe Marking"

Transcription

1 Guides & Standards For Facility Pipe Marking Facility Pipe Marking in commercial, public, school & retail buildings PIPE LABELING AND VALVE TAGGING GUIDELINES FOR YOUR FACILITY 2011 Graphic Products, Inc.

2 Suggested Standards For Marking Pipes & Valves ABBR. SERVICE TYPE PIPE LABEL VALVE TAG BAND COLOR BACKGROUND AND LETTERING COLORS CHWR Chilled Water Return CHWR (BLDG.)-CHV-## CHWS Chilled Water Supply CHWS (BLDG.)-CHV-## BLUE GREEN BACKGROUND, WHITE LETTERING CWR Condenser Water Return CWR (BLDG.)-CWV-## CWS Condenser Water Supply CWS (BLDG.)-CWV-## GREEN GREEN BACKGROUND, WHITE LETTERING CWGLR Chilled Water Glycol Return CWGLR (BLDG.)-CGLV-## CWGLS Chilled Water Glycol Supply CWGLS (BLDG.)-CGLV-## HWGLR Hot Water Glycol Return HWGLR (BLDG.)-HGLV-## GOLD GREEN BACKGROUND, WHITE LETTERING HWGLS Hot Water Glycol Supply HWGLS (BLDG.)-HGLV-## CTYW City Water CITY WATER (BLDG.)-CTWV-## DCWR Domestic Cold Water Return DCWR (BLDG.)-DCV-## DCWS Domestic Cold Water Supply DCWS (BLDG.)-DCV-## LIGHT BLUE GREEN BACKGROUND, WHITE LETTERING DHWR Domestic Hot Water Return DHWR (BLDG.)-DHV-## DHWS Domestic Hot Water Supply DHWS (BLDG.)-DHV-## DRAIN Drains* DRAIN (BLDG.)-DRAIN-## BROWN REFER TO ANSI STANDARDS BELOW DTR Dual Temp Return DTR (BLDG.)-DTV-## DTS Dual Temp Supply DTS (BLDG.)-DTV-## BLACK GREEN BACKGROUND, WHITE LETTERING FO Fuel Oil FO (BLDG.)-FOV-## WHITE YELLOW BACKGROUND, BLACK LETTERING HPR Heat Pump Return HPR (BLDG.)-HPV-## HPS Heat Pump Supply HPS (BLDG.)-HPV-## TEAL GREEN BACKGROUND, WHITE LETTERING LTHWR Low-Temp Hot Water Return LTHWR (BLDG.)-HWV-## LTHWS Low-Temp Hot Water Supply LTHWS (BLDG.)-HWV-## YELLOW GREEN BACKGROUND, WHITE LETTERING MTHWR Medium-Temp Hot Water Return MTHWR (BLDG.)-MTV-## MTHWS Medium-Temp Hot Water Supply MTHWS (BLDG.)-MTV-## ORANGE GREEN BACKGROUND, WHITE LETTERING HTHWR High-Temp Hot Water Return HTHWR (BLDG.)-HTV-## HTHWS High-Temp Hot Water Supply HTHWS (BLDG.)-HTV-## RED GREEN BACKGROUND, WHITE LETTERING STM Steam STEAM (BLDG.)-STV-## COND Condensate COND (BLDG.)-CNDV-## PINK YELLOW BACKGROUND, BLACK LETTERING NG Natural Gas GAS (BLDG.)-GASV-## GRAY YELLOW BACKGROUND, BLACK LETTERING CA Compressed Air COMP AIR (BLDG.)-CAV-## VAC Vacuum VACUUM (BLDG.)-VACV-## PURPLE BLUE BACKGROUND, WHITE LETTERING NOTE: Valve Tags need to comply with ANSI standards. Pipe Labels should be near valve to identify pipe content. *There are no standards for Drains. Follow ANSI Standards for background and letter colors; abbreviations may vary by facility. ANSI/ASME A Standard for the Identification of Pipes MATERIAL PROPERTIES BACKGROUND AND LETTERING COLORS FLAMMABLE Fluids which are a vapor or produce vapors that can ignite and continue to burn in air YELLOW BACKGROUND, BLACK LETTERING COMBUSTIBLE Fluids that may burn but are not flammable BROWN BACKGROUND, WHITE LETTERING TOXIC & CORROSIVE Fluids which are corrosive or toxic or will produce corrosive or toxic substances ORANGE BACKGROUND, BLACK LETTERING FIRE QUENCHING Water and other substances used in sprinkler fire-fighting piping systems RED BACKGROUND, WHITE LETTERING OTHER WATER Any other water, except for water used in sprinkler and fire-fighting piping systems GREEN BACKGROUND, WHITE LETTERING COMPRESSED AIR Any vapor or gas under pressure that does not fit a category above BLUE BACKGROUND, WHITE LETTERING DEFINED BY USER Defined by user BLACK BACKGROUND, WHITE LETTERING DEFINED BY USER Defined by user WHITE BACKGROUND, BLACK LETTERING DEFINED BY USER Defined by user PURPLE BACKGROUND, WHITE LETTERING DEFINED BY USER Defined by user GRAY BACKGROUND, WHITE LETTERING Pipe Marker Placement and Pipe Marker Size Chart on the back.

3 Ammonia Refrigeration System Pipe Marking Complies with IIAR (International Institute of Ammonia Refrigeration) Standards IIAR standards require the posting of a component identification and abbreviation reference chart to explain pipe marking in areas that are conspicuous to operating personnel. The reference chart shall be made of durable material that will remain legible. (IIAR #114 Section 7.0) ABBREVIATIONS Abbreviations for Ammonia System Components - Print abbreviations in black on yellow. 2. PHYSICAL STATE LIQ - Liquid - Black or white printed on orange VAP - Vapor - Black or white printed on blue* LIQ/VAP - Use both if both states exist *DuraLabel Sky Blue Premium Vinyl is recommended. 3. MARKER BODY AMMONIA printed in black on yellow 4. PRESSURE LEVEL HIGH Pressure (+70 psig) - Black or white printed on red LOW Pressure (=/-70 psig) - Black or white printed on green 5. FLOW DIRECTION Direction of flow of the system contents is indicated by arrows. Place arrows at one or both ends of the label. ABBR. SYSTEM PHYSICAL STATE PRESSURE LEVEL BD Booster Discharge VAP LOW CD Condenser LIQ HIGH DC Defrost Condensate LIQ HIGH ES Economizer Suction VAP LOW EQ Equalizer VAP HIGH FG Foul Gas VAP LOW HG Hot Gas VAP HIGH HGD Hot Gas Defrost VAP HIGH HPL High Pressure Liquid LIQ HIGH HSD High Stage Discharge VAP HIGH HSS High Stage Suction VAP LOW HTRL High Temperature Recirculated Liquid LIQ LOW HTRS High Temperature Recirculated Suction LIQ/VAP HIGH HTS High Temperature Suction VAP LOW LD Liquid Drain LIQ LOW LIC Liquid Injection Cooling LIQ HIGH LSS Low Stage Suction VAP LOW LT Liquid Transfer LIQ LOW LTRL Low Temperature Recirculated Liquid LIQ/VAP LOW LTRS Low Temperature Recirculated Suction LIQ LOW LTS Low Temperature Suction VAP LOW MTRL Medium Temperature Recirculated Liquid LIQ LOW MTRS Medium Temperature Recirculated Suction LIQ/VAP LOW MTS Medium Temperature Suction VAP LOW PL Purge Line VAP HIGH PO Pump Out PU Purge LIQ HIGH RV Relief Vent VAP HIGH TSR Thermosyphon Return LIQ/VAP HIGH TSS Thermosyphon Supply LIQ HIGH Abbreviations marked with this symbol are popularly used, but non-iiar approved. Pipe Marker Placement and Pipe Marker Size Chart on the back.

4 DURALABEL PRO 300 Prints 1/2" to 4" Tape Widths We did a thorough review of the various printers, and selected the DuraLabel PRO It s easy to use, supplies are in-expensive, and the support is by far the best of all the printer manufacturers we ve dealt with. - Darcy, Electrical Software Company Visit or call for information about pipe marker printers. Pipe Marker Placement Indicate direction of flow by labeling with arrows at one or both ends of the label Visible from the point of normal approach Below: Orientation of Labels Near valves, flanges & changes in pipe direction Both sides of ceiling, wall or floor penetrations At any line entry or re-entry point Every 25 feet to 50 feet is typical* On straight pipe runs in intervals sufficient for identification Ammonia Only: minimum of 1 per area through which the refrigeration piping passes *Every 40 feet for Ammonia pipe marking This label complies with the Suggested Standards For Marking Pipes & Valves Above: Label placement in relation to point of normal approach Pipe Marker Size Chart Letter and Label Dimensions in accordance with pipe diameter. NOTE: It is recommended that pipes less than.75" in diameter be labeled with a permanent tag. Outside Pipe Diameter Including Covering.75" " 1.5" - 2" 2.5" - 6" 8" - 10" Over 10" mm mm mm mm Over 254 mm Minimum Length of Label Field Color 8" 8" 12" 24" 32" 203 mm 203 mm 305 mm 610 mm 813 mm Minimum Height of Letters.5".75" 1.25" 2.5" 3.5" 13 mm 19 mm 32 mm 64 mm 89 mm DISCLAIMER: We know of no national codes covering the color coding of water pipes. Please check local and state building codes before implementing a color coding system. The suggested coding system presented here is not an official standard. Graphic Products, Inc. makes no representations or warranties of any kind, express or implied. Information in this guide is subject to change without notice. Except as expressly provided for in writing, the liability of Graphic Products, Inc. arising from the use of this guide is specifically excluded and Graphic Products, Inc. disclaims all warranties and any liability for damages of any kind and any liability whether in contract, tort under statute or otherwise for any injury, damage or loss whatsoever. No reliance should be placed on information contained or to be implied or inferred in this guide, and users of this guide should verify all information

5 Over 50 types of supplies which can be applied to almost any surface in nearly any setting, check out our website now! Portability Label in any location - indoor/outdoor No set up required Administrative Rights not required Preloaded with printer drivers, DuraSuite Labeling Software, templates, symbols and more! Designed to meet military security specs Display labels in harsh conditions Label indoors/outdoors Easily attach to equipment Scratch & fade resistant Color-coded Identify dirty, oily and rusty pipes Apply label to sleeve, then curl around pipe Sizes fit pipe diameters 1"-5.2" Custom lengths and larger diameters available Compliance with industry standards Rain & moisture resistance Indoor/outdoor lighting conditions Abrasion resistance Chemical resistance Overall longevity & durability Dura Labeling Software Pipe Marking made easy! The DuraSuite Labeling Software makes creating pipe markers fast and easy. Enter the pipe diameter, select the pipe contents, and pick an arrow to show the flow direction. The software automatically picks the right size and color for the label material and automatically sets the correct font size. In just a few moments the pipe markers you need will be in your hands ready to be installed. DuraSuite also includes software for other applications such as arc flash labels, RTK labels, and even custom labeling! Over 800 Symbols Included for Customizing!

6 Picture the Possibilities. Electrical Labeling Wayfinding Arc Flash Labeling Extreme Temperature Labeling Pipe Marking Labeling Valve Tags Military Labeling Safety Signs Reflective Labeling DuraLabel " to 9" Tape Widths DuraLabel " to 7" Tape Widths DuraLabel PRO 300 1/2" to 4" Tape Widths DuraLabel " to 4" Tape Widths DuraLabel /2" to 2" Tape Widths CALL TODAY!

PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES

PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Assign unit identification numbers to operating units of equipment within a class or subclass during the design phase of new buildings, additions,

More information

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION SECTION 15190 MECHANICAL IDENTIFICATION PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Identification of mechanical products installed under Division 15. B. Related Sections: 1.02 REFERENCES 1.

More information

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15. SECTION 15190 MECHANICAL IDENTIFICATION PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Identification of mechanical products installed under Division 15. B. Related Sections: 1. Section 09900 -

More information

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15. SECTION 15190 MECHANICAL IDENTIFICATION PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Identification of mechanical products installed under Division 15. B. Related Sections: 1. Section 09900 -

More information

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing). SECTION 15047 - IDENTIFICATION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Identification including necessary accessories indicated on Construction Documents and specified in this section or as required

More information

Page PRODUCT DESCRIPTION

Page PRODUCT DESCRIPTION Page 1 2004-02-29 PRODUCT FEATURES BASIC USES / RELATED USES Identification bands or markings for facility piping. BradySnap-On / Strap-On Vinyl: For normal duty, mechanically fastened. Custom or Blank

More information

Industrial Pipe Marking

Industrial Pipe Marking Industrial Pipe Marking Pipe and Valve Identification Specialists SPECIFICATIONS ASME (ANSI) Standard A13.1-2007 The ASME (ANSI) Standard for pipe identification is a widely used guideline in determining

More information

Page PRODUCT DESCRIPTION

Page PRODUCT DESCRIPTION Page 1 2003-02-26 PRODUCT FEATURES! BASIC USES / RELATED USES " Identification bands or markings for facility piping. # (Ultra-mark) Wrap-Around Polyester: For harsh environments, outdoor piping systems,

More information

Piping & Equipment Identification

Piping & Equipment Identification Piping & Equipment Identification Part 1 General 1.01 Description of Work A. Work in this section includes: Identification materials, including necessary accessories indicated on Contract Documents and

More information

Page PRODUCT DESCRIPTION

Page PRODUCT DESCRIPTION Page 1 2004-02-29 PRODUCT FEATURES BASIC USES / RELATED USES Self-adhesive identification bands or markings for facility piping, Self-StickingVinyl Weather-Code Outdoor Pipe Markers Medical Gas Pipe Markers

More information

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Specification Sections, apply to this Section. B. Related Sections:

More information

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION Buebtel/Perlcins Community Learning Center GPD - 2001271.15 SECTION 15075 MECHANICAL IDENTIFICATION PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 230553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 SUBMITTALS A.

More information

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 53 IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 53 IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe Markers. 2. Valve Tags. 3. Equipment Nameplates. 4. Underground Marking Tape. 5. Duct

More information

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT SECTION 220553 - IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT Henderson Engineers, Inc. PART 1 - GENERAL REQUIREMENTS 1.1 SUMMARY A. Extent of Plumbing work to be identified as required by this Section

More information

Brady B-595 Indoor/Outdoor Vinyl Tape for the GlobalMark Printer

Brady B-595 Indoor/Outdoor Vinyl Tape for the GlobalMark Printer Brady B-595 Indoor/Outdoor Vinyl Tape for the GlobalMark Printer Beginning March 1, 2010, Brady s leading outdoor grade vinyl for the GlobalMark Printer is being replaced by a new B-595 vinyl. This new

More information

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT SECTION 23 05 53 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Plastic Nameplates 2. Tags 3. Plastic Pipe Markers 4. Ceiling Tags 5. Detectable Underground Tape 6. Stencils PART 2 - PRODUCTS 2.1 MANUFACTURERS

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017 SECTION 23 0553 - MECHANICAL SYSTEMS IDENTIFICATION GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Facility Services Subgroup Preface for Divisions 21` through 28

Facility Services Subgroup Preface for Divisions 21` through 28 Facility Services Subgroup Preface for Divisions 21` through 28 1.1 EXECUTIVE SUMMARY A. This document provides standards for the Consultants and Contractors producing mechanical and electrical design

More information

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA The following standard specification is intended to be edited according to the specifics of the project. Brackets [ ] and areas shaded in gray [e.g. format] indicate requirements that are optional depending

More information

Trade of Plumbing. Module 1: Thermal Process and Mild Steel Pipework Unit 5: Drawing Phase 2

Trade of Plumbing. Module 1: Thermal Process and Mild Steel Pipework Unit 5: Drawing Phase 2 Trade of Plumbing Module 1: Thermal Process and Mild Steel Pipework Unit 5: Drawing Phase 2 Table of Contents List of Figures... 4 List of Tables... 5 Document Release History... 6 Module 1 Thermal Process

More information

B -345 PermaSleeve markers are supplied in roll form in a flattened format on a carrier designed for use with thermal transfer printers.

B -345 PermaSleeve markers are supplied in roll form in a flattened format on a carrier designed for use with thermal transfer printers. Technical Data Sheet BRADY B-345 HIGH TEMPERATURE PERMASLEEVE(TM) MARKER TDS No. B-345 Effective Date: 10/27/2017 Description: GENERAL Print Technology: Thermal Transfer Material Type: Irradiated polyvinylidene

More information

B. Samples: For color, letter style, and graphic representation required for each identification material and device.

B. Samples: For color, letter style, and graphic representation required for each identification material and device. PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL SECTION 23 00 10 - MECHANICAL SCOPE OF WORK PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01

More information

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

Never fill any required clearance space with insulation or any other building materials surrounding the chimney. INSTALLATION AND MAINTENANCE INSTRUCTIONS 1700ºF Air-Cooled Temp/Guard Chimney Sizes 8-16 Listing No. MH8251 Tested to UL103/ULC-S604 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCE

More information

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT SECTION 21 05 53 IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2015-2015 ARCAT, Inc. - All rights reserved PART 1 GENERAL

More information

Health and Safety at Work (Hazardous Substances Markings for Pipework Connected to Above Ground Stationary Tanks) Safe Work Instrument 2017

Health and Safety at Work (Hazardous Substances Markings for Pipework Connected to Above Ground Stationary Tanks) Safe Work Instrument 2017 This safe work instrument is administered by WorkSafe New Zealand. For more information please see: Website: http://www.worksafe.govt.nz Contact phone: 0800 030 040 Contact address: PO Box 165 Wellington

More information

Brady B-595 Indoor/Outdoor Vinyl Tape for the GlobalMark Printer

Brady B-595 Indoor/Outdoor Vinyl Tape for the GlobalMark Printer Brady B-595 Indoor/Outdoor Vinyl Tape for the GlobalMark Printer Beginning March 1, 2010, Brady s leading outdoor grade vinyl for the GlobalMark Printer is being replaced by a new B-595 vinyl. This new

More information

Health and Safety at Work (Hazardous Substances Markings for Pipework Connected to Above Ground Stationary Tanks) Safe Work Instrument 2017

Health and Safety at Work (Hazardous Substances Markings for Pipework Connected to Above Ground Stationary Tanks) Safe Work Instrument 2017 Health and Safety at Work (Hazardous Substances Markings for Pipework Connected to Above Ground Stationary Tanks) Safe Work Instrument 2017 This safe work instrument is approved under section 227 of the

More information

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION SECTION 15190 MECHANICAL IDENTIFICATION PART 1 GENERAL 1.01 SECTION INCLUDES A. Section Includes: 1. Nameplates. 2. Tags. 3. Stencils. 4. Pipe Markers. 1.02 SUBMITTALS A. Submit valve chart and schedule,

More information

DEPARTMENT OF DEFENSE STANDARD PRACTICE

DEPARTMENT OF DEFENSE STANDARD PRACTICE INCH-POUND 29 January 2009 SUPERSEDING MIL-STD-1247C 13 October 1989 DEPARTMENT OF DEFENSE STANDARD PRACTICE MARKINGS, FUNCTIONS AND HAZARD DESIGNATIONS OF HOSE, PIPE, AND TUBE LINES FOR AIRCRAFT MISSILE,

More information

British Standard Pipe Markers (BS1710-BS4800)

British Standard Pipe Markers (BS1710-BS4800) British Standard Pipe Markers (BS1710-BS4800) Why Pipe Marking? Brady pipe markers enhance safety, save time and reduce costs. Enhance safety. Unmarked pipes and valves can cause danger to life and damage

More information

A/E REVIEW CHECKLIST HVAC

A/E REVIEW CHECKLIST HVAC A/E CHECKLIST HVAC Reviewers should - Use Checklists when reviewing any type of VA construction project for the following disciplines: Site and Landscape, Architectural, Structural, Plumbing, Fire Protection,

More information

B-342 is available in white, yellow, black, red, orange, green, blue, violet, pink, gray, and brown. Details: RANGE OF WIRE DIAMETER (in)

B-342 is available in white, yellow, black, red, orange, green, blue, violet, pink, gray, and brown. Details: RANGE OF WIRE DIAMETER (in) Technical Data Sheet BRADY B-342 PERMASLEEVE MARKER TDS No. B-342 Effective Date: 04-Jun-2010 Description: GENERAL Print Technology: Thermal transfer and dot matrix Material Type: Irradiated polyolefin

More information

AVAILABLE SIZES. Label Length (mm) Label Length (inches) PART NUMBER EXAMPLE EET P 4. Color (Yellow) Material (Polyester) Width (15.

AVAILABLE SIZES. Label Length (mm) Label Length (inches) PART NUMBER EXAMPLE EET P 4. Color (Yellow) Material (Polyester) Width (15. Pressure sensitive adhesive labels for safety, warning and electrical box identification. The labels are designed to protect against abrasion, environmental and chemical exposure. Electrical and safety

More information

Table of Contents. For Pre-Sales Support or Questions call

Table of Contents. For Pre-Sales Support or Questions call Printer Media Guide Table of Contents I. OVERVIEW: Printing with Barcodes PRINTER TYPES: Desktop vs. industrial PRINT METHOD: Direct thermal vs. thermal transfer PRINT MATERIAL: Choosing the right labels

More information

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT SECTION 230553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Nameplates. B. Tags. C. Stencils. D. Pipe Markers. 1.2 RELATED REQUIREMENTS A. Section 099123 - Interior

More information

TABLE OF CONTENTS. Product Listing Index. Look for this symbol. It let s you know which products are available in 4-Color Process. BLUE FROG PRINTING

TABLE OF CONTENTS. Product Listing Index. Look for this symbol. It let s you know which products are available in 4-Color Process. BLUE FROG PRINTING www.bluefrogprinting.net BFP16C The Roll Labels, Decals, Banners & Static Clings you ve come to expect and so much more! Product Listing Index Blue Frog Printing is proud to offer a large selection of

More information

A/E REVIEW CHECKLIST PLUMBING/FIRE PROTECTION/SANITARY

A/E REVIEW CHECKLIST PLUMBING/FIRE PROTECTION/SANITARY A/E REVIEW CHECKLIST PLUMBING/FIRE PROTECTION/SANITARY Reviewers should - Use Checklists when reviewing any type of VA construction project for the following disciplines: Site and Landscape, Architectural,

More information

A. Product Data: For each electrical identification product indicated.

A. Product Data: For each electrical identification product indicated. SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Technical Data Sheet. Close Print TDS BRADY B-342 PERMASLEEVE MARKER. 1 of 5 10/12/ :57. TDS No. B-342 Effective Date: 18/05/2009

Technical Data Sheet. Close Print TDS BRADY B-342 PERMASLEEVE MARKER. 1 of 5 10/12/ :57. TDS No. B-342 Effective Date: 18/05/2009 Close Print TDS Technical Data Sheet BRADY B-342 PERMASLEEVE MARKER TDS No. B-342 Effective Date: 18/05/2009 Description: GENERAL Print Technology: Thermal transfer and dot matrix Material Type: Irradiated

More information

FITTINGS AND HOSES TOOL

FITTINGS AND HOSES TOOL FITTINGS AND HOSES INGERSOLL-RAND FITTINGS AND HOSES The Ingersoll-Rand line of ruggedly convenient hose reels and recoil hoses are pressurerated for optimized pneumatic performance, even in the toughest

More information

Heat Exchanger Construction Checklist

Heat Exchanger Construction Checklist Heat Exchanger Checklist Project: Pump tag: Building: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing. The checklist

More information

B-342 can also be printed using laser marking method. Laser marking has very good environmental, abrasion, and chemical resistance.

B-342 can also be printed using laser marking method. Laser marking has very good environmental, abrasion, and chemical resistance. Technical Data Sheet BRADY B-342 PERMASLEEVE MARKER TDS No. B-342 Effective Date: 10/27/2017 Description: GENERAL Print Technology: Thermal transfer and dot matrix Material Type: Irradiated polyolefin

More information

Solutions, Standards and Software Kolmetz Handbook of Process Equipment Design PROCESS FLOW SHEET (ENGINEERING DESIGN GUIDELINE)

Solutions, Standards and Software Kolmetz Handbook of Process Equipment Design PROCESS FLOW SHEET (ENGINEERING DESIGN GUIDELINE) Page : 1 of 94 KLM Technology Processing Plant www.klmtechgroup.com, Standards and Software Rev 01 March 2015 Rev 02 KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor

More information

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations. General Conditions: 1. Deliver all food service equipment as specified herein, including that which is reasonably inferred, with all related items necessary to complete work shown on contract drawings

More information

2 IN 1 18GA. NAILER/STAPLER KIT

2 IN 1 18GA. NAILER/STAPLER KIT 2 IN 1 18GA. NAILER/STAPLER KIT performance plus MODEL: 8210NS INSTRUCTION MANUAL COPYRIGHT 2005 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC. IMPORTANT INFORMATION 2-YEAR LIMITED WARRANTY FOR THIS 18

More information

SBP Self Laminating Wire and Cable Markers

SBP Self Laminating Wire and Cable Markers SBP Self Laminating Wire and Cable Markers Technical Datasheet TTDS-211 Revision 10 - April 2018 SBP is a clear vinyl film with a white thermal transfer printable area. On application, the clear film over-laminates

More information

2012 IMC Performing Commercial Mechanical Inspections

2012 IMC Performing Commercial Mechanical Inspections 2012 IMC Performing Commercial Mechanical Inspections Based Primarily on the 2012 International Mechanical Code (IMC ) and the 2012 International Fuel Gas Code (IFGC ) as applicable. ` Welcome I am You

More information

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions PO Box 480 Ph: 417-235-7821 Monett, MO 65708 Fax: 417-737-7140 Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions These installation instructions are recommendations

More information

Abstract - Aerial Infrared Thermography. g Thermal Mapping as an Asset Management Tool. for Universities, Large Campuses, Buildings

Abstract - Aerial Infrared Thermography. g Thermal Mapping as an Asset Management Tool. for Universities, Large Campuses, Buildings Abstract - Aerial Infrared Thermography g Thermal Mapping as an Asset Management Tool for Universities, Large Campuses, Buildings Questions, Comments or Suggestions to: Matthew Reuter (267)738-5816 Email:

More information

SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION

SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION test TECHNICAL NOTE On Cold-Formed Steel Construction $5.00 Cold-Formed Steel Engineers Institute Washington, DC www.cfsei.org 866-465-4732 SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION

More information

Basic Principles and Operation of Transformer

Basic Principles and Operation of Transformer Basic Principles and Operation of Transformer CONSTRUCTIONAL ASPECTS Cores In order to enhance core s magnetic properties, it is constructed from an iron and silicon mixture (alloy). The magnetic core

More information

Self Laminating Wire and Cable Markers

Self Laminating Wire and Cable Markers SBP Self Laminating Wire and Cable Markers Technical Datasheet TTDS-211 Revision 12 - December 2018 SBP is a clear vinyl film with a white thermal transfer printable area. On application, the clear film

More information

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS PART 1 GENERAL 1.01 Scope of Work A. Provide material, accessories, tools, equipment and labor as required for the complete fabrication

More information

Radar Tank Gauging for Asphalt Inventory Measurement

Radar Tank Gauging for Asphalt Inventory Measurement White Paper November 6, 2009 Radar Tank Gauging for Asphalt Inventory Measurement This document describes the correct selection of a radar tank gauge for inventory measurement and maintainability on an

More information

INSUL-FLUE is used to reduce the danger of radiant heat from smoke pipe, flue pipe, gas vents, etc. igniting combustibles.

INSUL-FLUE is used to reduce the danger of radiant heat from smoke pipe, flue pipe, gas vents, etc. igniting combustibles. INSUL-FLUE OWNER S MANUAL (6 inch) High Heat Resistant Thimble and Insulating Sleeve for Smoke Pipe When Passing Through Any Combustible Wall September 1993, Revision A INTRODUCTION CONGRATULATIONS ON

More information

CRAFTSMAN EXAMINATION, JUNE 2008 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

CRAFTSMAN EXAMINATION, JUNE 2008 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 9195 CRAFTSMAN EXAMINATION, JUNE 2008 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE

More information

SECTION IDENTIFICATION OF HVAC PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

SECTION IDENTIFICATION OF HVAC PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers. SECTION 23 05 53 IDENTIFICATION OF HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes nameplates, tags, stencils and pipe markers. B. Related Sections: 1. Section 09 05 00 Common

More information

SECTION COMMON WORK RESULTS FOR HVAC

SECTION COMMON WORK RESULTS FOR HVAC SECTION 23 05 00 COMMON WORK RESULTS FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Ball Valve. 2. Hangers and Supports. 3. Identification Tags and Sleeves. 1.2 INCLUDED SECTIONS A. Section

More information

BUILDING PLAN REVIEW REQUIREMENTS

BUILDING PLAN REVIEW REQUIREMENTS TOWNSHIP OF NORTH FAYETTE BUILDING DEPARTMENT COMMERCIAL PLAN REVIEW REQUIREMENTS BUILDING PLAN REVIEW REQUIREMENTS In order to perform a thorough Building Plan Review, the following specifications, drawings

More information

ADDENDUM 4 BID OPPORTUNITY NO

ADDENDUM 4 BID OPPORTUNITY NO ` Corporate Finance Department Materials Management Branch ADDENDUM 4 BID OPPORTUNITY NO. 74-2005 Page 1 of 8 NEWPCC SECONDARY EFFLUENT UV DISINFECTION FACILITY URGENT PLEASE FORWARD THIS DOCUMENT TO WHOEVER

More information

Submersible Water Pumps

Submersible Water Pumps User Manual [Revision 4.0 January 2018] READ THIS MANUAL CAREFULLY BEFORE USE FAILURE TO DO SO MAY RESULT IN INJURY, PROPERTY DAMAGE AND MAY VOID WARRANTY. KEEP THIS MANUAL FOR FUTURE REFERENCE. Products

More information

ARCHITECTURAL SYMBOLS

ARCHITECTURAL SYMBOLS Plan Symbols Symbol 2 A-4 3 L-5 AA A-6 ARCHITECTURAL SYMBOLS Definition Wall section No. 2 can be seen on drawing No. A-4. Detail section No. 3 can be seen on drawing No. A-5. Building section A-A can

More information

Standard Operating Procedure for the Amray 1810 Scanning Electron Microscope Version: 29 NOVEMBER 2014

Standard Operating Procedure for the Amray 1810 Scanning Electron Microscope Version: 29 NOVEMBER 2014 Standard Operating Procedure for the Amray 1810 Scanning Electron Microscope Version: 29 NOVEMBER 2014 1. Utility Requirements a. System power is supplied by two 120 VAC/20 A circuits. When doing maintenance

More information

ADDENDUM NO. 4 November 15, Page 1

ADDENDUM NO. 4 November 15, Page 1 ADDENDUM NO. 4 November 15, 201 8 Page 1 PROJECT MANUAL FOR CONSTRUCTION OF HVAC REPLACEMENT FOR NORTH OCONEE HIGH SCHOOL FOR OCONEE COUNTY SCHOOLS WATKINSVILLE, GEORGIA DATED: SEPTEMBER 14, 2018 CUNNINGHAM,

More information

Cleaning & Maintenance Advice Textured Glass.

Cleaning & Maintenance Advice Textured Glass. Cleaning & Maintenance Advice Textured Glass. Viridian ScalaTexture Viridian ScalaMirage Viridian ScalaDesign Viridian LuminaMist Cleaning of Glass This information is offered as general information only.

More information

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450)

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 www.icc-rsf.com INSTALLATION AND OPERATION INSTRUCTIONS "Model VIP" CHIMNEY TYPE: FACTORY BUILT

More information

U of I Facilities Standards Updates for 2017

U of I Facilities Standards Updates for 2017 U of I Facilities Standards Updates for 2017 Updates to the U of I Facilities Standards will occur on a periodic basis (typically all standards will be reviewed for accuracy & completeness every 3 years),

More information

Aluminum Electrolytic Capacitors Power Miniaturized General Purpose - Snap-In

Aluminum Electrolytic Capacitors Power Miniaturized General Purpose - Snap-In Aluminum Electrolytic Capacitors Power Miniaturized General Purpose - Snap-In FEATURES Useful life: 2000 h at +105 C, > 5000 h at +85 C Voltage range from 16 V to 100 V Polarized aluminum electrolytic

More information

SKY : 3400 to 3600 MHz Wide Instantaneous Bandwidth High-Efficiency Power Amplifier

SKY : 3400 to 3600 MHz Wide Instantaneous Bandwidth High-Efficiency Power Amplifier DATA SHEET SKY66313-11: 3400 to 3600 MHz Wide Instantaneous Bandwidth High-Efficiency Power Amplifier Applications FDD and TDD 4G LTE and 5G systems Supports 3GPP Bands N78, B22, and B42 Driver amplifier

More information

SmartZone-2 & SmartZone-4

SmartZone-2 & SmartZone-4 SmartZone-2 & SmartZone-4 Quick-Start Guide UPDATED 2011-7-26 This guide is intended to give the installer a brief set of instructions about how to set up the XCI Zoning SmartZone System. For more detailed

More information

DILLARD S TEST PROTOCOL FOR DILR US CANDLE HOLDER AND ACCESSORIES (INDOOR & OUTDOOR) (V14)

DILLARD S TEST PROTOCOL FOR DILR US CANDLE HOLDER AND ACCESSORIES (INDOOR & OUTDOOR) (V14) Test Date: Reviewed By/Date: SCOPE: Accessories include: Rings, Jar Shades, Jar Toppers, Jar Sleeves & Jar Plates SUPPLEMENTAL PROTOCOLS * Candle DILR-HL-PTCL-09400- US * CA Prop 65 CPSD-AN-PTCL- 06572-US

More information

Relay (R1) 003. Balancing Valve. Slab Pump (P1) Max. 4 pipe diameters apart. Injection Pump (P2) 150 No 24V only. Power. Off.

Relay (R1) 003. Balancing Valve. Slab Pump (P1) Max. 4 pipe diameters apart. Injection Pump (P2) 150 No 24V only. Power. Off. Mechanical - Application e Stage Setpoint Control A -1 12/08 /Off Switch Relay (R1) 003 Slab Sensor (S1) 072 or 073 Balancing Valve Slab Pump (P1) Max. 4 pipe diameters apart Pump Heating System Injection

More information

30 Bending Brake. Model Assembly and Operating Instructions. Distributed exclusively by Harbor Freight Tools.

30 Bending Brake. Model Assembly and Operating Instructions. Distributed exclusively by Harbor Freight Tools. 30 Bending Brake Model 41311 Assembly and Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Copyright 1999 by Harbor Freight Tools. All

More information

Compressors, Chillers & Condensers

Compressors, Chillers & Condensers MARINE CONDENSER ACME MHX MARINE CONDENSER ACME Type MHX condensers are manufactured with the latest technology marine condenser tubing to provide compact size and cost effective use. STANDARD DESIGNS

More information

SECTION IDENTIFICATION OF PLUMBING, PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

SECTION IDENTIFICATION OF PLUMBING, PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers. SECTION 22 05 53 IDENTIFICATION OF PLUMBING, PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes nameplates, tags, stencils and pipe markers. B. Related Sections: 1. Section 09 05 00

More information

IDENTIFICATION DEPOT, INC. 206 East Second Street Washington, NC PHONE FAX

IDENTIFICATION DEPOT, INC. 206 East Second Street Washington, NC PHONE FAX Engraved Plastic Nameplates 1/16 rigid 2 ply blended acrylic extruded sheet with cap and core permanently fused together. Material is shatterproof and chip resistant. Matte finish meets ASTM D 709 Type

More information

U5700 Submersible Liquid Level Pressure Transducer

U5700 Submersible Liquid Level Pressure Transducer High Accuracy CE Compliant Compact Variety of Pressure Port Configurations Waterproof Optional Stainless Steel Snubber IP68 Rated Connection and Submersible Polyurethane Jacketed Cable Gage, Sealed, Absolute,

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION INSTALLATION & MAINTENANCE INSTRUCTIONS The GX series control valve is an electronic pressure regulator designed to precisely control the pressure of gaseous media proportional

More information

Copeland Digital Scroll

Copeland Digital Scroll Copeland Digital Scroll Technology & Advantages Presented by: Bruce Hilsabeck Application Engineer Copeland Australia / New Zealand Introduction 1. Scroll Compressor Basics 2. Digital Compressor Technology

More information

Pipe Laser Model No Instruction Manual

Pipe Laser Model No Instruction Manual Pipe Laser Model No. 40-6690 Instruction Manual Congratulations on your choice of this Pipe Laser. We suggest you read this instruction manual thoroughly before using the pipe laser. Save this instruction

More information

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide www.i2systems.com i2systems is a registered trademark of Integrated Illumination Systems, Inc. LightLink is a trademark of Integrated Illumination Systems, Inc. 2018 Integrated Illumination Systems, Inc.

More information

Aluminum Electrolytic Capacitors Radial, High Temperature, Low Impedance, High Vibration Capability

Aluminum Electrolytic Capacitors Radial, High Temperature, Low Impedance, High Vibration Capability Aluminum Electrolytic Capacitors Radial, High Temperature, Low Impedance, High Vibration Capability 40 RTM lower Z longer life 50 RMI 25 C 46 RTI high vibration QUICK REFERENCE DATA DESCRIPTION VALUE Nominal

More information

Deep offshore gas fields: a new challenge for the industry

Deep offshore gas fields: a new challenge for the industry Deep offshore gas fields: a new challenge for the industry Emil Gyllenhammar Aker Solutions PAU, FRANCE 5 7 APRIL 2016 The challenge Remote gas fields in offshore depths of up to 3000 m Far away from the

More information

Disc Caliper Brake Model DBSE

Disc Caliper Brake Model DBSE AIR CHAMP PRODUCTS User Manual Disc Caliper Brake Model DBSE i In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject to

More information

PORTAGE COUNTY WATER RESOURCES DRAFTING STANDARDS. Date: January 26, 2001

PORTAGE COUNTY WATER RESOURCES DRAFTING STANDARDS. Date: January 26, 2001 PORTAGE COUNTY WATER RESOURCES DRAFTING STANDARDS Date: January 26, 2001 Portage County Water Resources Drafting Standards. AutoCad 2000/Land Development Desktop R2 Friday, January 26, 2001 Preface: Part

More information

RCM DIRECT READING FLOWMETER

RCM DIRECT READING FLOWMETER RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:

More information

ITEM Pipe Thread Kit (10 Piece Set - 7 Dies) Assembly and Operating Instructions

ITEM Pipe Thread Kit (10 Piece Set - 7 Dies) Assembly and Operating Instructions ITEM 94098 Pipe Thread Kit (10 Piece Set - 7 Dies) Assembly and Operating Instructions 3491 Mission Oaks Blvd., Camarillo, CA 93011 Copyright 2006 by Harbor Freight Tools. All rights reserved. No portion

More information

3 Dynatel M Series Locating and Marking System DOCUMENT NEW- TO- THE- WORLD TECHNOLOGY OBSOLETE DAMAGE PREVENTION PIN- POINT ACCURACY SAFETY

3 Dynatel M Series Locating and Marking System DOCUMENT NEW- TO- THE- WORLD TECHNOLOGY OBSOLETE DAMAGE PREVENTION PIN- POINT ACCURACY SAFETY 3 Dynatel M Series Locating and Marking System NEW- TO- THE- WORLD TECHNOLOGY PIN- POINT ACCURACY SAFETY DAMAGE PREVENTION Introducing the 3M Dynatel M-iD Series Locating and Marking System. NEW TECHNOLOGY

More information

FLEXDC INSTALLATION GUIDE

FLEXDC INSTALLATION GUIDE Please read entire guide prior to starting installation. NOTES 1. IP40 and lower tape must be installed indoors only. 2. Installation must be carried out by a licensed electrician & executed in accordance

More information

Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02

Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02 Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02 1. INTRODUCTION This standard is written to provide the professional surveyor (Surveyor) and the client with a guideline for producing

More information

Repair Manual 12 PL PILOT

Repair Manual 12 PL PILOT Repair Manual 12 PL PILOT 12 PL PILOT REPAIR MANUAL INDEX Introduction... 1 Elastomer Materials... 2 Disassembly... 3 Assembly... 7 Testing... 11 NOTE: We reserve the right to modify or change, without

More information

1. ASME A Scheme for the Identification of Piping Systems.

1. ASME A Scheme for the Identification of Piping Systems. SECTION 40 05 53 - IDENTIFICATION FOR PROCESS PIPING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Nameplates. 2. Tags. 3. Stencils. 4. Pipe markers. 5. Labels. 6. Lockout devices. B. Related Requirements:

More information

Switch Mode Power Supply

Switch Mode Power Supply New Product Switch Mode Power Supply SJC-ZS SJC-ZS, newly released Power Supply with CE marking. SJC-ZS is our best standard power supply for material cost reduction time saving for installation by DIN-rail

More information

Misc Accessories. Fiber-Tip Markers DURA-INK #15 MARKER

Misc Accessories. Fiber-Tip Markers DURA-INK #15 MARKER Fiber-Tip Markers FINE TIP DURA-INK #15 MARKER 96022... Red 1... 72 96023... Black 1... 72 96025... Blue 1... 72 96026... Green 1... 72 96030... Black 2... 72 96033... Black 3... 72 Ideal for fine line

More information

Working with Process Flow DiagramsChapter1:

Working with Process Flow DiagramsChapter1: Chapter 1 Working with Process Flow DiagramsChapter1: In this chapter, you learn about designing piping with AutoCAD MEP. The design phase consists of conceptualizing, modeling, and documenting the necessary

More information

TYPE 5610 & 5610Q SINGLE O-RING CARTRIDGE SEAL

TYPE 5610 & 5610Q SINGLE O-RING CARTRIDGE SEAL 1 Foreword These instructions are provided to familiarize the user with the seal and its designated use. The instructions must be read and applied whenever work is done on the seal, and must be kept available

More information

SF 6 Characteristics and Re-use Concept

SF 6 Characteristics and Re-use Concept DILO. Sustainably tight. SF 6 Characteristics and Re-use Concept www.dilo-gmbh.com Peter Jannick / Solvay Fluor Overview What is sulphur hexafluoride? Decomposition products SF 6 gas specifications IEC

More information