Power Distribution System SVS02
|
|
- Chad Lucas
- 6 years ago
- Views:
Transcription
1 Power Distribution System SV Description The ETA power distribution system SV is designed to accommodate the electronic circuit breaker series ESS0003 or electronic circuit protector ESX0. It distributes the current supplied by a switch mode power supply up to 40 A to 4, 8, or 6 channels. Input connections are via. The individual circuit breakers can be plugged in. Loads are connected via springloaded screwless terminals. The power distribution includes integral wiring of the signalisation of the individual channels which can be combined to a group signal. The SV can be snapped onto a DIN symmetrical rail. Suitable for ESS0003 ESX003 0S SV08... Ordering information Type SV Power distribution system for ESS0003 short circuit current limited DC 4 V applications max. 40 A continuous load two integral circuit breakers ( and ): overcurrent protection of group signalisation of power distribution system, red LED glashes upon trip of insulated wire bridges Y included without jumpers SBSP0A (for unused positions) Version, max. number of circuit breakers ESS0003 on the power distribution system 04 4 channels (F...F4) 08 8 channels (F...F8) channels (F...F) 6 6 channels (F...F6) Screw terminals for power supply DC 4 V P30 3 loopthrough terminals (X ) max. 0 mm for DC 4 V () / DC 4 V () / functional earth Load outputs per channel (F.. Fn, n = 04, 08,, 6) L50 5 per channel, max. 8 A each () group output () internally bridged over all channels () protected load output (), per channel () DC 4 V () () DC 4 V () () functional earth Signal outputs S5 signal terminal () for group signal, 5pole, complete with plugin terminal, wiring 5 x max. mm / without connector sleeve, max. 0 A: () internal DC 4 V supply for signalisation via insulated wire bridge from () to () () external supply possible DC 4 V for signalisation () signal output group signalisation () additional output DC 4 V () () additional functional earth Control input E00 without control input Fitting variants B0 complete with screwless springloaded terminals, (max. mm, without connector sleeve) (standard) B0 complete with plugin screw terminals (max. mm, without connector sleeve) SV 6P30 L50 S5 E00 B0 Technical data Modular Power distribution system for shortcircuit limited DC 4 V applications up to max. 40 A continuous load, max. voltage DC 3 V. Three (max. 0 mm /AWG 8) for: DC 4 V () = X DC 4 V () = X (functional earth) = X for connecting the DC 4 V power supply max. 40 A Modular design ESS0positions F...F4 (..F8,...F or...f6): SV04 / 4 channels / F...F4 = Kl. X...X4 SV08 / 8 channels / F...F8 = Kl. X...X8 SV / channels / F...F = Kl. X...X SV6 / 6 channels / F...F6 = Kl. X...X6 5 per channel complete with Combicon screwless connectors, wiring 5 x max. mm (AWG 4)/ without connector sleeve max. 8 A: () group output (), internally bridged across all channels () load output (), per channel () DC 4 V () () DC 4 V () () functional earth Signal terminal () for group signal complete with Combicon screwless connectors, wiring 5 x max. mm (AWG 4)/ without connector sleeve, max. 0 A (signal contact ESS0): () internal DC 4 V supply for signalisation of terminal X via insulated jumper from () to (), protected by () external supply possible DC 4 V for signalisation, protected by () signal output group signalisation () additional output DC 4 V () () additional functional earth Selective overcurrent protection and for group signalisation of the power distribution system, red LED blinks after has tripped (see schematic diagram). Reset of circuit breakers: momentarily press red actuator button Protection class to: IP0 Insulation coordination to IEC 60934: 0 kv / pollution degree Dielectric strength AC 500 V Temperature range: 0..0 C (without condensation) for DIN symmetrical rail mounting EN x Dimensions: see dimensional drawing 3
2 Power Distribution System SV Dimensions SV6 Insulated wire bridge, not fitted ( pcs enclosed) Rail EN 50035x,5 (not supplied) F4 = 09 F4 = 4 F8 = F8 = 6.5 F = 33 F = 99 F6 = 95 F6 =.63 Typ: SV X X X F5 F6 F F8 F9 F0 F F F3 F4 F5 F6 X3 X6 X8 X9 X0 X X X3 X4 X5 X6 X X X4 X5 X red LED blinks after has tripped DC 4 V power supply 5.60 screwless springloaded terminals Schematic diagram SV(n) n = 04, 08,, 6 *) see application example for insulated wire bridge *) SO Line () GND () Line () GND () Line () GND () Line () GND () LOAD (L) LOAD (L) LOAD (L) LOAD (L) ESS0003 ESS0003 ESS0003 ESS0003 X X X LED V blinks after has tripped : no visual indication 3 V 3 V X *) X X3 Xn R Circuit breakers and : shown in tripped condition F F F3 Fn 4
3 Power Distribution System SV Dimensions SV04, fitted with ESS red LED blinks after has tripped 5 0 (05) (43) Elektronischer Schutzschalter Electronic Supplementary Protector 003DC4 VA/A Insulated wire bridge, not fitted ( pcs enclosed) Rail EN 50035x,5 (not supplied) Typ: SV04 X X X X X X3 X4 DC 4 V power supply screwless springloaded terminals 5
4 Power Distribution System SV Dimensions SV04, fitted with ESX Insulated wire bridge SO X X X L S L L power supply screwless springloaded terminals 6
5 Power Distribution System SV Application example for jumper to replace Application example for insulated wire bridge The signalling pathway of the group signalisation is as follows: feedin of DC 4 V potential in ( = terminal 3) via inbuilt overcurrent protection via all signal contacts of the fitted circuit breakers type ESS0003 back to signal output of group signalisation ( = terminal 3) Terminal (group signalisation) wire bridge from () to () internal DC4V feed for signalisation Thus plus potential of terminal X is connected to () In operating condition (i.e. all circuit breakers plugged in and functional) the signalling pathway () to () is closed. If the distribution rail is not completely fitted with ESS0003, the open pathway () to () may be closed by means of a jumper type SBSP0A Typ: SV04 X X X Typ: SV04 X X X3 X4 X X X X X X3 X4 Terminal X Protected load output () of CBE position F takes over protection of () terminals of all CBEs F up to Fn (n= 04, 08,, 6) Accessories Jumper SBSP0A Germany SBSP0A xxxx AC 40 V / DC 65 V, A top view 84 Insulated wire bridge Y Two insulated wire bridges are supplied with the power distribution system. They may be used for: Channel : internal DC 4 V supply for signalisation wire bridge from () to () Signal circuit () to () protected by Signal circuit () to (SO) protected by Channel X: Protected load output () of CBE position F takes over protection of () terminals of all CBEs F up to Fn (n= 04, 08,, 6) terminals 34 bridged blade terminals DIN 4644A 60.8 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted.
Power Distribution System SVS02
Power Distribution System SV2 Description The ETA power distribution system SV2 is designed to accommodate the electronic circuit breaker series ESS20003 or electronic circuit protector ESX0. It distributes
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationPower Distribution System SVS20
Power Distribution System SV Description The power distribution system SV for rail mounting distributes the current supplied by a DC V switchmode power supply to channels and selectively protects the connected
More informationPower Distribution System SVS18
Power Distribution System SVS8 Description The power distribution system SVS8 optimises the DC V distribution in automation and process control, in the production area of the chemical industry and in power
More informationPower distribution system SVS25
Power distribution system SVS Description The new power distribution system type SVS meets all requirements of the automation technology with regard to reliably overcurrent protection and optimised current
More informationElectronic Circuit Breaker with reset input ESS20-1..
Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker ESS for System SVS Description The electronic circuit breaker ESS is designed to ensure selective disconnection of individual loads in industrial systems which are powered by
More informationElectronic Circuit Breaker ESS20-0..
Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,
More informationElectronic Circuit Protector ESX10-T
Electronic Circuit Protector ESX0-T Description Electronic circuit protector type ESX0-T is designed to ensure selective disconnection of systems. power supplies, which are widely used in industry today,
More informationElectronic circuit protector REX12
Description The new electronic overcurrent protection REX12 consists of the supply module EM12-T and the single or double channel electronic circuit protector REX12-T which allows modular side-by-side
More informationREX12 Electronic Circuit Protector
Description The compact and flexible all-in-one solution REX consists of several perfectly matched components. It comprises the EM12-T supply module for the plus and minus potential via a single or double
More informationElectronic circuit breaker ESS30-Sxxx-DC24V
Electronic circuit breaker ESS30-Sxxx-DC2V Description The electronic circuit protector ESS30-S with physical isolation is the globally unique electronic over protection for DC 2 V applications as a low
More informationElectronic Circuit Protector ESX10
Electronic Circuit Protector ESX0 Description Electronic circuit protector type ESX0 is designed to ensure selective disconnection of DC 24 V load systems. DC 24 V power supplies, which are widely used
More informationSwitched mode power supply for DIN rail mounting type SMP21 DC24V/10A
Switched mode power supply for DIN rail mounting type SMP2 DC24V/0A Description Switched mode power supply for rail mounting, with independent change-over of input voltages (AC 5/20 V), integral passive
More informationSwitched mode power supply for DIN rail mounting type SMP23 DC24V/40A
Switched mode power supply for DIN rail mounting type SMP DC4V/40A Description Switched mode power supply (SMP) for rail mounting, three-phase supply voltage, high efficiency, integral input filter and
More informationREX12 Electronic Circuit Protector
Description The compact and flexible all-in-one solution REX consists of several perfectly matched components. It comprises the EM12-T supply module for the plus and minus potential via a single or double
More informationPHOENIX CONTACT
Selective circuit breaker CLIPLINE Data sheet 100464_en_05 PHOENIX CONTACT 2009-11-17 1 Description The electronic circuit breaker, which has a design width of just 12.5 mm, selectively protects all 24
More informationSmart Power Relay E I...
Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic
More informationDatasheet. Electronic Circuit Protection ESX10-T
Datasheet Electronic Circuit Protection ESX0-T selected in fixed values from 0.5 A...2 A. Failure and status indication are provided by a multicolour LED and an integral short-circuit-proof status output
More informationPHOENIX CONTACT
Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 PHOENIX CONTACT 2010-12-17 1 Description The electronic circuit breaker can be used in applications that cover all aspects of the switched-mode
More informationSolid State Remote Power Controller E
Solid State Remote Power Controller E-048-60. Description The E-T-A Solid State Remote Power Controller (SSRPC) E-048-60. is an opto decoupled transistorised switching device providing both protection
More informationPHOENIX CONTACT - 09/2009
Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits
More informationCircuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You
Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current
More information38 Series - Relay interface modules A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More information38 Series - Relay interface modules A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationWireless multizone receiver RDE-MZ6
s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output
More informationMCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description
Universal current transducer Data sheet 104059_en_05 PHOENIX CONTACT 2011-03-09 1 Description MCR-SL-CUC-...-I and MCR-SL-CUC-...-U active current transducers convert DC, AC, and distorted currents into
More informationLED Driver Compact fixed output. Udriver LC 25/30/35/40W 600/700/800/900mA fixc SC ADV ADVANCED series
Udriver LC 5/3/35/4W 6/7/8/9mA fixc SC ADV ADVANCED series Product description Fixed output LED Driver Can be either used build-in or independent with clip-on strain-relief (see accessory) Constant current
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationMeasuring current transformers of the W AB(P) series
Measuring current transformers of the W AB(P) series W-AB(P)_D00074_02_D_XXEN/07.2017 Measuring current transformers of the W AB(P) series Product description Measuring current transformers of the W -AB
More informationModeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS
OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS P Other accessories DELAY UNIT Type Product code Description Weight [kg] Package [pc] BZ-BX-X230-A 36696 enables to delay the undervoltage release tripping
More informationNo-wear isolation of potentials in terminal block design
TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly
More informationElectronic alarm signalling unit TES 20. for temperature and standard signals ENA EN
Electronic alarm signalling unit TES 20 ENA117.01 EN for temperature and standard signals Universal alarm signalling unit (constructional width 4 T) for Temperature (temperature monitor) with Pt 100 IEC
More informationCP-T range Product group picture
Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details
More informationMiniature circuit-breakers S 280 UC series. System pro M. Technical data
Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum
More information38 Series - Relay Interface Modules A
Series - Relay Interface Modules 0.1-2 - 6 A - Relay interface modules for use with PLC systems, mm wide - Sensitive DC coil or AC/DC coil version - Supplied with integral coil - Instant removal of relay
More informationSwitching power supplies CP range, Linear power supplies CP-L range. Content
CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional
More informationAdvantages. Applications
3 s KH 250 General Data Rated input voltage 2 Vac Rated output voltage 2 Vac Rated power 250 VA Ambient temperature +40 C Degree of protection IP 40 Advantages Compensation for mains voltage fluctuations
More informationMINI-PS AC/2X15DC/1
MII-PS-100-240AC/2X15DC/1 Power supply unit ITERFACE Data sheet 100299_en_04 1 Description PHOEIX COTACT - 2010-10-20 Features MII POWER is the extremely slim power supply unit with constructional widths
More informationSRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS
ELECTRICAL ENGINEERING DIVISION Distribution Network Department SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELA T150.2 en SRA 2250/6 Resistor specification The SRA 2250/6 Resistor is intended to increase
More informationCP-T range Benefits and advantages
Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More information27/04/2015
Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement
More information38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C),
More informationMeasuring current transformers of the W, W series
Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000
More informationEA16, EB16, EA17, EA19
MOVING-IRON METERS EA16, EB16, EA17, EA19 and EA12 TYPES AMMETERS and VOLTMETERS CATEGORIES OF METER CLIMATIC VERSIONS If it is not written otherwise in the order, these meters are intended to use in moderate
More information120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240
Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to
More information05/09/2014
48 x 48 Digital LCD Timer 814 Part number 88857005 Relay output digital timers LCD or LED (815E) Multi-range Multi-voltage 1 or 2 relay outputs Reset function on panel (Timers 815, 815E) Data saved in
More informationThrough and Ground Conductor Terminal Blocks 290 Series
11 474 Through and Ground Conductor Terminal Blocks 290 Series 0.34-1. mm"f-st" 0.31-1 mm"s" 1 00 V/6 kv/3 2 1 AWG 22-16"f-st" AWG 22-18"s" I N 13. A Terminal block width mm / 0.197 in 0.34-1. mm"f-st"
More informationVEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage
More informationLED Driver Compact fixed output
Driver C 5W 35-6mA flexc SC advanced series Product description Can be either used build-in or independent with clip-on strain-relief (see accessory) Constant current Adjustable output current between
More informationMOVING-IRON METERS EA16, EB16, EA17, EA19, EA12 TYPES
MOVING-IRON METERS EA16, EB16, EA17, EA19, EA12 TYPES AMMETERS and VOLTMETERS EA12 EA19 EA17 EA16 EB16 EA16, EB16, EA17, EA19 and EA12 moving-iron meters are intended for measuring AC voltage or AC current.
More informationIndustrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12. Catalog Add-On IC 10 AO 2012 SIRIUS. Answers for industry.
Industrial Controls SIRIUS R_* in sizes S00/S0 to S Catalog Add-On IC 0 AO 0 SIRIUS Answers for industry. Controls Contactors and Contactor Assemblies for Switching Motors Price Groups PG B, H / Introduction
More informationProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv
Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv When temperatures are to be measured using Pt100 resistance thermometers in high-voltage environments, standard temperature transmitters
More informationLED Driver Compact fixed output
Driver C 6W -4mA flexc SC ADV ADVACED series Product description Can be either used build-in or independent with clip-on strain-relief (see accessory) Constant current ED Driver Adjustable output current
More informationSINEAX V 604s Programmable multifunctional transmitter
SINEAX V 60s f direct currents, direct voltages, temperature senss, teletransmitters potentiometers 00 SINEAX V60s is a multifunctional transmitter f top-hat rail assembly with the following main characteristics:
More information2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)
46 Series - Relays for railway applications 8-16 A 46 SERIES Features Plug-in power relays: 8 A, 2 pole 16 A, 1 pole Complies with EN 45545-2:2013 (protection against fire of materials), EN 61373 (resistance
More informationAdd-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Add-on modules DX 3 63A for MCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4.
More information3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket
41 Series - Low profile PCB relays 8-12 - 16 A Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16
More information83 Series - Modular timers 16 A. Features
Features 83 Series - Modular timers 16 A 83.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 83.11 - delay, multi-voltage 22.5 mm wide Six time scales from 0.1s to 20h High
More informationmm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi
34 Series - Slim electromechanical PCB relays 6 A Features 34.51 Ultra-slim 1 Pole - 6 A relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw or screwless sockets 1 Pole
More informationSwitching Devices Contactors and Contactor Assemblies for Switching Motors
Switching Devices Contactors and Contactor Assemblies for Switching Motors groups 41B, 41H / Introduction Power contactors for switching motors /5 General data /11 SIRIUS RT10 contactors, -pole,... 50
More informationPage 13-2 Page Page 13-7
Page -2 Page -6 MINIATURE CIRCUIT BREAKERS UP TO 63A 1P, 1P+N, 2P, 3P and 4P versions IEC rated current In: 1-63A IEC short-circuit capacity Icn: 10kA (6kA for 1P+N) Trip characteristic curve: Type B,
More informationData sheet. W-Series WDU 4 BL
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationOvercurrent Protection / 7SJ45
Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers
More informationEAO Product Information. Series 84
EAO Product Information Series Switches and Indicators Switches and Indicators Index Series Description Page 539 Product Assembly Page 540 Mounting Instruction Page 541 Product Range - pushbuttons for
More informationV2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC
P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationData sheet. W-Series WDU 10
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More informationPHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.
Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103129_en_01 PHOENIX CONTACT - 05/2008 1 Description QUINT POWER power supply units highest system availability
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationPHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system
More informationData sheet... W-Series WDU 2.5
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationData sheet. W-Series WDU 2.5 RT
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationInstallation / Monitoring Technique
Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems IP 5883 0249633 IP 5883 ND 5018/035 ND 5018/030 According to IEC/EN 62 020, VDE 0663 For AC and
More informationData sheet. W-Series WDU 2.5
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationPulse Scaler for DIN Rail Attachment
Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationTheta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.
Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta
More informationMeasuring current transformers of the W B series
Measuring current transformers of the W B series W-B_D00075_01_D_XXEN/09.2015 Measuring current transformers of the W B series Product description Measuring current transformers of the W B series are highly
More informationV2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...
P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector
More informationOutput of three-phase motors at 50 Hz and 400 V
RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements
More informationDatasheet - PROTECT-IE-02
Print - Create PDF - Create EXCEL file 20.04.2011-18:28:57h Datasheet - PROTECT-IE-02 Input expander / PROTECT-IE Input expander Input for up to 4 sensors per interface e.g.: magnetic safety switches type
More information38 Series - Relay interface modules A. Features /
Series - Relay interface modules 0.1-2 - 6-8 A Features 1 Pole - 6 A electromechanical relay interface modules, 6.2 mm wide. Ideal interface for PLC and electronic systems Sensitive DC coil or coil versions
More informationSubject to changes 11/2003 Page 1/7
Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3
More informationVARIOCON. Modular Contact Inserts
Modular Contact Inserts 1. Short The modular contact inserts are based on the triedand-tested COMBICON technology. They are available with the screw connection system and on the equipment side also as
More informationLR Position Switches TECHNICAL DATASHEET
TECHNICA DATASHEET Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 69 contact blocks available actuators available M assembled connector versions Silver
More informationModeion MOULDED CASE CIRCUIT BREAKERS BL1000S
G MOULDED CASE CIRCUIT BREAKERS BL1000S G BL1000S COMMERCIAL INFORMATION 3P Switching units, withdrawable device...g4 Overcurrent releases...g5 Signalling units...g5 Residual current monitor...h6 Current
More informationPowerPlex Compact Module PP-C-COM24
Description The PowerPlex Compact Module has been designed for the 12 V or 24 V DC-System of special vehicles, buses or boats. It provides inputs for switches and sensors as well as power outputs with
More informationE-STOP relays, safety gate monitors
Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel
More informationCapacitor Switching Contactors
Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationNotes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC
Features DIN-Rail 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel
More informationDatenblatt. W-Series WDU 10
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationEMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004
Current Monitoring Relay Data Sheet 08/2004 Functions Structure Current monitoring of direct and alternating current in 1-phase networks with settable threshold values, starting override and response delay
More informationRISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar
Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power
More informationSeries P. Applications
Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any
More information