1 Research, Development and Production of Telecommunications Measuring Instruments Presents
2
3 ACT6000 Advanced Communication Tester.what is it? Level Generator Selective Level Meter Spectrum & Network Analyzer TDR Faults Locator Digital Multimeter White Noise Generator Applications for TLC services.what is it useful for? Tests and Analysis on lines or any other communication way Attenuation & Frequency response Noise, Level, Distortion & Cross-talk Return-loss & Longitudinal Balance Faults location & Micro-Interruptions Noise immunity & Data-rate estimation Air Traffic - Voice and data comms. Highway data communications Railway data communications Energy transport data communications (PLC)
4 Summary - Applications - Internal Circuits and Functions - Menu Hierarchy - Connections and Commands - DELT Automatic Line/Channel Certification - SELT Automatic Line Qualification - SELT pre-configured transmissive tests - Electrics Tests - Events Tests - Transmissive Tests - Special Utilities ACT6000 (starting from 2012) The ALT2000 evolution ALT2000 (2001 to 2011) - High Resolution Color Display - Increasing of battery operation time - New battery charger circuit - USB ports to Pen-Drive and PC connection - SELT Sequence without external device and PC - Resistive Bridge to Resistance Faults Location - Operative Band Extension up 6 MHz (base) and up 35 MHz (optional)
5 ACT6000 Advanced Communication Tester Applications: - Qualification and troubleshooting of symmetric copper pairs - Spectral analysis of base and high band signals (up to 6 or 35 MHz) - xdsl preconfigured tests (Bit-Rate estimation and PSD included) Transmissive Qualification & Diagnosis Metallic Qualification Faults Finding & Faults Location Telephone Signalling Tests and Special Functions - Noise - AC and DC Voltage - Telephone Simulation - Return-Loss - AC and DC Capacitance - Power Spectrum Density - Long. Balancement - Insulation and Loop Resistance - Noise Immunity - Cross-Talk - Low Insulation Location - Results and Schreenshot export - Attenuation - TDR Faults location - xdsl S/N ratio evaluation - Microinterruptions test - xdsl Bit-Rate evaluation - Impulsive Noise test
6 ACT6000 Advanced Communication Tester Base Circuits & Measurements - Attenuation - Cross-Talk - Microinterruptions - Noise - Power Spectrum Density - Impulsive Noise Level Generator Active Bridge Selective Level Meter Spectrum Analyzer Digital Multimeter Resistive Bridge - Return-Loss - Long. Balance-Loss - TDR Fault Location - AC/DC Voltage - AC/DC Capacitance - Loop Resistance - Res. Insulation Resistive Faults Location
7 ACT6000 Level Generator & Selective Level Meter 200 Hz 6 MHz (or 35 MHz) operative band Advanced Communication Tester Main Functions Spectrum & Network Analyzer 200 Hz 6 MHz (or 35 MHz) operative band TDR Fault Locator & Events test from 2 to 8,000 meters Digital Multimeter Resistance Faults Locator & Special Functions
8 ACT Functions Group Menu Hierarchy Main Menu From this menu, by selecting the icon-number with the arrows and confirming with Enter it is possible to access the available functions. Quick access is possible by typing on the keypad the icon number. 1- Line Tests Access the sub-menu for automatic and pre-configured copper pairs qualification in SELT or DELT mode and POTS services. 2 - TDR Fault locator Access the TDR sub -menu to find the End-of -Line and possible faults on copper pairs. 5 Signal Analyzer Access the sub - menu for signal generation, selective measurements, spectral or network analysis on copper pairs or other lines or devices. 6 File Manager Access the sub - menu for management and export of saved file-measurements. 3 Event tests Access the sub - menu to monitor some events as microinterruptionsor impulsive noise on copper pairs and other lines types. 7 Config. & Utility Access the sub-menu for the initial setup of the instrument (date/hour, display.. and measurement parameters). 4 Multimeter Access the sub-menu for metallic measurements as voltage, resistance, insulation, capacitance of copper pairs and other devices 8 Slave mode Special configuration to set the instrument as Slave to perform some automatic and pre-configured End-to - End tests on copper pairs and lines.
9 ACT Connections and Commands description The front panel is free from connections to make the usage of the lateral keypad and the bottom function keys easy. All the data and graphs are shown on the color and high resolution display. The powerful human interface allows the quick menu selection to the intuitive use of the instrument. Connections Headset RTX Connector TX Connector Connector (Main Line) (Secondary Line) PC Connection USB port USB port LED Battery Power Supply (Service only) to PC to Pen-Drive status input
10 Copper Pairs / Channel Qualification: DELT Automatic Sequence Introduction MASTER SLAVE data communications from Base Band to xdsl band MASTER SLAVE PCM MUX digital stream PCM MUX voice / data communications in Base Band via digital stream By the use of a couple of ACT6000, each implemented by the advanced optional software ASW-1/II, it is allowed the automatic End-to-End test to perform an accurate and bilateral transmissive Test Sequence to produce the Line / Channel Qualification / Certification.
11 ESPORTAZIONE MISURE SU PC Funzioni Line / Cannel Speciali Certification: : Configuration for DELTesting Automatic Sequence End-to-End Start MASTER configuration (to put on the MDF Central Office or street cabinet ). Connect the line and the ground reference to the RTX connector. From the Main Menu select the item 1 Line Tests, and from this the 1. BALANCED LINE TESTS menu. By the F2 key select DELT mode and by the F3 key select the service type for the line to be test (i.e. MODEM 56k), then push F5 key to start the automatic procedure. From this moment the MASTER sends on the line under test an audible intermittent beep (useful as pair finder). SLAVE configuration (to put on the street cabinet or user side). Connect the line and the ground reference to the RTX connector. From the Main Menu select the item 8 Slave Mode and from this the 1. BALANCED LINE TESTS From this moment, if the line good (no interrupted or shorted), it is audible the beep sent from the MASTER. Push the F5 key to start the automatic sequence.
12 ESPORTAZIONE MISURE SU PC Funzioni Line Certification: Speciali : DELT Test Double-End-Line-Testing Automatic Sequence End-to-End Before the transmissive tests, using the same line under test, the SLAVE sends to the MASTER its data for the right identification, then the MASTER starts the test sequence related to the selected service (e.g. MODEM 56k). From the SLAVE s display it is possible to follow the progress of the test sequence and the related local results. Finished the tests the SLAVE sends automatically to the MASTER its results. The progress of the transmission is shown on the its display Coincidentally, from the MASTER s display it is possible to follow the progress of the tests sequence and the related local results. Received the data stream from the SLAVE, the MASTER s display it is completed with all the results (Central and Subscriber side), included the possible Bit-Rate estimation if selected some masks as ADSL, ADSL2+ or VDSL2 services. Pushing the F1 key it is possible to save the test on the internal memory.
13 ESPORTAZIONE MISURE SU PC Funzioni Line Certification: Speciali : DELT Test Double-End-Line-Testing Automatic Sequence End-to-End Finished the tests sequence all the results are shown on the summary table. All the possible fail results, related to the selected mask, are highlighted in red. Pushing the F5 View it is possible to analyze the graphic details of single transmissive measurement. Each graph (with exception of the Insertion loss) shows the local (Master) and remote (Slave) results with different colors: - Green: local unit - Violet: remote unit
14 Copper Pairs pre-qualification: SELT Automatic Sequence Introduction Applications for copper pairs qualification ACT6000 can perform many measurements in Single-End mode. To operate in confortable way it is possible to perform the measurements from the Central side without technician and remote instrument at the opposite side of the open line under test (with 4500 meters maximum lenght) By a special Automatic Sequence (available with the Advanced Software 1/II) it is possible to perform a complete copper pair qualification, electrics and transmissive tests included, in 90 seconds!
15 Line Qualification: SELT Automatic Sequence Cable setup 1 opened Line Config & Utility 7 From the Main Menu select the 7 Config. & Utility group and then 8.CABLE SETUP. By the arrows select the preponderant * Cable Type, then push Enter to confirm. Note *: preponderant it means the main sector of the line to be test, or the first going out cable from the MDF room if the test is performed by the Central Office.
16 Line Qualification: SELT Automatic Sequence End-of-Line finding by TDR opened Line 1 2 Before to start the Automatic Sequence it is suggested to find the End-of-Line echo by the TDR function (see slide No. 32) and verify the congruent line lenght according to the PVF related to the selected cable type. TDR Fault Locator Notes: Some local measurements (as the Electrics, Noise, Long. Balance-Loss and Next) are valid for any line lenght. Vice-versa for a possible valid SELT Insertion-Loss measurement it is necessary to find (manually by the TDR) the valid End-of-Line echo within 5 km of distance. Return-Loss: due to the impossibility to terminate the line-end for SELT Automatic Sequence, in some cases the bad result of the R.L. can be false, above all when the line under test is short (under meters) or when selected a Base Band mask (Voice or MODEM 56k). In this case it is suggested to apply the termination at the lineend (e.g. 600 Ohm for Base Band masks) and perform the R.L. measurement as single real time test see slide N meters PVF 0.600
17 Line Qualification: SELT Automatic Sequence Setup and Start opened Line 1 Finished the tests sequence all the results are shown on the test summary table. If some measured value is out of the preconfigured threshold limits the result is shown in red. About the Return-Loss see note on slide N 16 Selected the line service type (e.g. SHDSL mask) it is possible to start the test.
18 Line Qualification: SELT Automatic Sequence Setup and Start opened Line Pressing the View key it is possible to analyze the details of the electric and transmissive measurements.
19 SELTests single pre-configured real time transmissive measurements opened or loaded * Line Sequence Noise Ret-Loss Long-Bal NEXT PSD This operative mode (with continuously graphs update) it is very useful to select quickly the good line to assign the possible service according to some transmissive performances. * see the note on slide N 16
20 Electrics Tests by DMM Digital Multimeter opened or shorted * Line Introduction: After the SELT Test Sequence or previous indications, it is possible to perform some metallics measurements to verify the electrics parameters of the line under test, or to localize the possible faults / anomalies. By the DMM Function (allowed with the optional internal Module): - Extraneous AC/DC Voltage on the line (AC power influence or DC voltage coupling). - AC Capacitance to measure the mutual capacitance and Q values between a b wires. - DC Capacitance (capacitor discharge method) to measure the capacitance value (loads included as telephone devices) among a - b - and c (Gnd) wires. - Low Insulation finding, among a - b - and c (Gnd) wires. - Low Insulation location, among a - b - and c (Gnd) wires, by Resistive Bridge (RFL Function). - Loop Resistance between a b wires *, to estimate the line length and verify the junctions quality. - Resistive Line Balancement, between a b * related to c (Gnd) wires. - Impedance Response of the line or load connected to a b
21 Electrics Tests by DMM Digital Multimeter - VOLTAGE opened Line 1 4 DMM Multimeter Select Line voltage
22 Electrics Tests by DMM Digital Multimeter AC CAPACITANCE & Q opened Line 1 4 DMM Multimeter Select Capacitance
23 Electrics Tests by DMM Digital Multimeter DC CAPACITANCE opened Line 1 4 DMM Multimeter Select Capacitance
24 Electrics Tests by DMM Digital Multimeter LOOP RESISTANCE 1 4 DMM For this test it is necessary the support of another technician at the remote side of the line under test Multimeter Select Resistance Short the a - b wires according to the instructions highlighted on the advice.
25 Electrics Tests by DMM Digital Multimeter LOOP RESISTANCE Real time measurement (by ACT-18 optional module) 1 4 DMM For this test it is necessary the support of another technician at the remote side of the line under test Multimeter Short the a - b wires according to the instructions highlighted on the advice.
26 Electrics Tests by DMM Digital Multimeter RESISITVE BALANCEMENT 1 4 DMM For this test it is necessary the support of another technician at the remote side of the line under test Multimeter Select R-Balan R-Balan Short the a-b-c wires according to the instructions highlighted on the advice.
27 Electrics Tests by DMM Digital Multimeter - INSULATION opened Line 1 4 DMM Multimeter Select Insulation
28 Electrics Tests by DMM Digital Multimeter FAULTS LOCATION DMM For this test it is necessary the support of another technician at the remote side of the line under test RFL kω kω Short the right wires according the instructions highlighted on the advices.
29 ACT6000 Resistive Bridge Low Resistive Insulation finding examples b a c b a c b a c A Fault between one wire (i.e. b) and Ground (or other wire) B Fault between b and a wire, using the Ground reference (or other wire) C RX RX a RX b RX a RX b RL RY Rb-c (o a-c) Rb-a Rb-c Ra-c RY a RY b RY a RY b Fault between one wire (i.e. b) and Ground (or other wire) + Fault between one wire (i.e. a) and Ground (or other wire) b a c b a c D RX a RX b Rb-a Ra-c (o b-c) Fault between b and a wire + + Fault between one wire (i.e. a) and ground (or other wire) E RX a RX b Rb-c (o a-c) Rb-a Ra-c (o b-c) RY a RY b RY a RY b Fault between b and a wire + Fault between one wire (i.e. a) and ground or.. + Fault between one wire (i.e. b) and ground or Note: Assigned the right resistivity / km value of the conductors, the tester calulates and shows automatically on the display the related lenght of the RX and RY sectors.
30 Electrics Tests by DMM Digital Multimeter FAULTS LOCATION with extraneous DC voltage finding If during the Insulation test is detected an extraneous DC voltage among the wires connected to a b points and /or to c (GND reference), this advise will appears. WARING! DC VOLTAGE OVER THE LINE VERIFY LINE CONNECTIONS PRESS ANY KEY TO RESTORE In this case is not possible any Insulation test! DMM For this test it is necessary the support of another technician at the remote side of the line under test To localize the possible fault it is possible to select a special test among the functions of the Resistance/Insulation menu. The typical situation is a low insulation for water/oxide presence between the line under test (e.g. Pair 2) and one powered lines (e.g. Pair 1) as represented on the scheme below. Central Office battery set 48 V GND c b a services ACT6000 Resistive Bridge Low Insulations localization with extranesous DC voltage Tester to fault distance Ring Pair 1 Tip Pair 2 good wire Pair 3 RX RX RX RX R.fault R.fault R.fault good line Fault to line-end distance (strap) powered line line under test Rw Rw RY RY RY RY good wire strap GND
31 Fautl Electrics Tests by DMM Digital Multimeter FAULTS LOCATION Line multi-section setup Digital Multimeter b a c By a new menu, it is now possible to configure a multisection line, very useful setup to perfom possible accurate Loop Resistance and Fault Location tests m / 0,4 615 m / 0,57 21 m / 0,6 10kΩ
32 TDR Fault Locator / End-of-Line estimation opened Line 1 2 DMM The TDR function allows the localization of possible faults / anomalies on the line under test or estimate its total length. Any impedance mismatches on the line are shown as upward pulses when the impedance increases (up to the open circuit ), and downward pulses when the impedance decreases (up to the short circuit ) meters PVF To know the distance from the test point it is necessary to find the final echo adjusting the better range and move the Marker at the beginning of the echo as represented at the right picture. For accurate distance estimation it is suggested to select the proper cable type (as described on slide N 15) associated to the correct PVF value.
33 TDR Fault Locator / long term monitor opened Line quiet TDR Function By special setting, the TDR can capture occasional echoes before of the End-of- Line, due to occasional events as short circuit, false contacts, microinterruptions etc. as the example below. Distance to new echo Distance to end-of-line Normal mode quiet quiet Move the Marker on new echo Set peak mode and wait Set Relative mode
34 Events Tests Microinterruptions / Impulsive Noise Microinterruption Test Impulsive Noise Test
35 Special Utilities : Measurements saving and exporting Finished any tests, the results (data and graphics) can be saved on the internal memory of the instrument. The tests can be named by the keypad with 8 characters maximum. For example, typing Cable and Pair number C23_P36 (Cable No. 23 / Pair No. 36) or with last 8 numbers of the Subscriber Telephone number. Without the typing of any name, the test will be saved with the default data (test type and date). By pushing the View key all the saved measurements can be re-viewed in the same way as they were saved. The screenshot is exportable on the USB Pen- Drive as image in BMP format. By pushing the Export key the row data of the saved tests can be exported on the external USB Pen-Drive in CSV format. The CSV file can be opened by Windows Excel application. Selecting and managing the row data it is possible to convert these in graphs and edit the data base.
36 Special : CSV file opening Exported the CSV file on the USB Pen-Drive, and connected it to the USB port of the PC, a folder (named ACT-6000) will be found. Inside of the above folder will be found another sub-folder (named with the Serial Number of the instrument).. i.e. # Inside of the S/N folder will be found one or more folders related to the exported test types, for example: - the automatic SELT tests identified with M111, - the automatic DELT tests identified with M112. Example: inside the folder M112 (DELT Sequence) will be find: - Or a BMP image related to the previous screenshot exporting; - the CSV file related to a DELT Sequence saved with C28_CP36 name. Clicking on the CSV file (if the PC works with Windows Office) a Excel file will be automatically opened on which is included the tester identification and the tests parameters, the summary of the results and the row data of the spectral measurements, very useful to create possible interactive graphics Rumore locale (dbm) Rumore remoto (dbm) Ret, Loss locale (db) Ret, Loss remoto (db) Bilan, Long, locale (db) Bilan, Long, remoto (db) -80 Attenuazione (db)
37 Special : PDF Test Reports (by CSV file Conversion) By the new PC application ACT6000 CSV-PDF Converter is now possible to convert the CSV files related to the SELT or DELT test in PDF Test Reports. By the control panel, it is possible to select the CSV file to be convert. After the possible summary compilation and pushing the Generate Report, a complete Test Report will be shown. It can be saved in PDF format.
38 Special : PC link (by USB standard cable) By the new PC program ACT6000 Utility it is possible to connect the Instrument to the PC by a standard USB cable. This is an alternative method to the USB Pen-drive to export or import various data. After the Serial Com selection (assigned by Windows OS) the utility allows the download of BMP (screen shot), CSV files and the Cables database. Using the special Editor functions it is possible to edit and to upload to the instrument a new Cables database, Transmissives Threshold Limits and a possible Firmware updating.
A C T Advanced Communication Tester
A C T 6 0 0 0 Advanced Communication Tester SINE SIGNAL & NOISE GENERATOR - SELECTIVE LEVEL METER CROSS TALK METER - SPECTRUM & NETWORK ANALYZER LONGITUDINAL BALANCE & RETURN LOSS METER MICROINTERRUPTION
More informationA C T Advanced Communication Tester
A C T 6 0 0 0 Advanced Communication Tester SINE SIGNAL & NOISE GENERATOR - SELECTIVE LEVEL METER CROSS TALK METER - SPECTRUM & NETWORK ANALYZER LONGITUDINAL BALANCE & RETURN LOSS METER MICROINTERRUPTION
More informationA C T Advanced Communication Tester
A C T 6 0 0 0 Advanced Communication Tester SINE SIGNAL & NOISE GENERATOR - SELECTIVE LEVEL METER CROSS TALK METER - SPECTRUM & NETWORK ANALYZER LONGITUDINAL BALANCE & RETURN LOSS METER MICROINTERRUPTION
More information20Hz to 2.2MHz Transmissive Measurements
20Hz to 2.2MHz Transmissive Measurements Level Generator & Selective Level Meter Automatic Phone & Line Qualifier Psopho & Audio Distortion Meter Spectrum & Network Analyzer White Noise Generator TDR Fault
More informationQUICK REFERENCE GUIDE
QUICK REFERENCE GUIDE Menu and Keys Copper Test TDR, RFL, DMM, wideband, POTS xdsl Test ADSL2+ Annex A/B*, VDSL2 System Software version/options, date/time, power settings Function Keys Escape/Back Power
More informationDragonLink Advanced Transmitter
DragonLink Advanced Transmitter A quick introduction - to a new a world of possibilities October 29, 2015 Written by Dennis Frie Contents 1 Disclaimer and notes for early release 3 2 Introduction 4 3 The
More informationMaxTester 610 KEY FEATURES AND BENEFITS THE MAXTESTER 600 SERIES SPEC SHEET SMARTER COPPER TESTING FOR INSTALLATION TECHNICIANS
SMARTER COPPER TESTING FOR INSTALLATION TECHNICIANS Smarter verification of copper pairs and location of faults during the installation and repair of voice and DSL circuits. SPEC SHEET KEY FEATURES AND
More information3M Dynatel Far End Device III
3M Dynatel Far End Device III User s Guide PAIR 1 GND CO PAIR 2 F1 F2 STATUS Dynatel Far End Device III 1 1/2 0 Future-Proof Testing Platform February 2009 78-8140-2657-7-A 3 2 3M Dynatel Far End Device
More informationT-BERD /MTS-4000 Multiple Services Test Platform Copper Services Module
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS T-BERD /MTS-4000 Multiple Services Test Platform Copper Services Module Key Features Complete copper testing from POTS through full-spectrum VDSL/VDSL2 up to
More informationFar End Device II Model 1342
3 Far End Device II Model 1342 Operating Instructions Optimized for ADSL2+ May 2007 78-8130-0876-6-C Table of Contents Introduction...3 Power-up...4 Connecting the 3M Far End Device II...5 Installing,
More informationDynatel 965DSP / 3M Far-End-Device Setup
Dynatel 965DSP / 3M Far-End-Device Setup For Line Qualification Testing ( Voiceband & Wideband Digital Services ) Welcome Dynatel TM 965DSP Subscriber Loop Analyzer S/N 9751YP w 1998 3M Ver 5..4 USA Setup
More informationHT1000/2 Series Copper Wire Analyser
HT1000/2 Series Copper Wire Analyser HT1000/2 Series Copper Wire Analyser Vectored DSL testing for VDSL2 lines Noise finder via a 30 MHz spectrum analyzer 7 user selectable auto tests Incremental pair
More informationFOR 20 YEARS WE PRODUCE THE INSTRUMENTS FOR YOU!
FOR 20 YEARS WE PRODUCE THE S FOR YOU! OTDR OTDR GAMMA LITE Fiber tipe Singlemode Optical Connector FC / PC Wavelength, nm 1310±20 / 1550±20 Dynamic range, db 32 / 30 Attenuation Dead zone, m 10 Event
More informationVBRC 4. Radio Communicator. Installer Manual
VBRC 4 Radio Communicator Installer Manual 17 December 2014 CONTENT 1. INTRODUCTION...3 2. SYSTEM STRUCTURE...3 3. SYSTEM PROGRAMMING WITH PC SOFTWARE...5 4. TROUBLESHOOTING...6 5. FIRMWARE UPGRADE...7
More information3M Dynatel Far-End Device (FED II) Applications
Testing with the 965DSP and Far-End-Device () The is like having a helper at the far end of the pair while you are performing AUTO tests with the 965DSP. It can qualify new lines or identify service problems
More informationResults You Can Count On
20 khz to 300 MHz Noise Generator for Realistic Gfast Testing Up to 24 Independent Noise Ports Gfast technology promises to bring a wealth of new opportunities to Service Providers as well as manufacturers
More informationAXS-200/ MHz COPPER TEST SET
AXS-200/610 30 MHz COPPER TEST SET 2011 GLOBAL xdsl TEST EQUIPMENT GROWTH LEADERSHIP AWARD As part of the SharpTESTER Access Line, this tool identifies copper problems affecting triple-play quality SPEC
More informationVIAVI ONX 580. Technical Assistance: GO-VIAVI;
VIAVI ONX 580 Table of Contents 2.0 Outside Plant Testing... 5 2.1 POT Dialer... 5 3.0 XDSL Rate Test... 7 3.1 Single Pair Test... 7 3.2 Bonded Pair Test... 9 4.0 Copper Testing... 12 4.1 AutoTests OneCheck
More informationFirmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.
LINE TESTER LT51 The LT51 Line Tester is a portable handheld battery powered instrument. It combines the features of several pieces of test equipment such as a Selective Level Meter / Spectrum Analyser,
More informationAA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer
AA-35 ZOOM Antenna and cable analyzer RigExpert User s manual . Table of contents Introduction Operating the AA-35 ZOOM First time use Main menu Multifunctional keys Connecting to your antenna SWR chart
More informationApplication Series. SunSet xdsl: TDR Testing Techniques for DSL Circuits
a step ahead Application Series SunSet xdsl: TDR Testing Techniques for DSL Circuits 22 Great Oaks Blvd, San Jose CA 95119 USA ph 1 408 363 8000 fax 1 408 363 8313 info@sunrisetelecom.com www.sunrisetelecom.com
More informationBasic Transceiver tests with the 8800S
The most important thing we build is trust ADVANCED ELECTRONIC SOLUTIONS AVIATION SERVICES COMMUNICATIONS AND CONNECTIVITY MISSION SYSTEMS Basic Transceiver tests with the 8800S Basic Interconnects Interconnect
More informationCopper Lines and High Speed
Copper Lines and High Speed Application Note 52 Line quality is no coincidence Testing transmission lines for ADSL Test Solutions with the PSM-137 Selective Level Test Set Contents Testing transmission
More informationIT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual
IT-24 RigExpert 2.4 GHz ISM Band Universal Tester User s manual Table of contents 1. Description 2. Specifications 3. Using the tester 3.1. Before you start 3.2. Turning the tester on and off 3.3. Main
More informationMIDLAND PROGRAMING G14
MIDLAND PROGRAMING G14 1. PROGRAMMING CAPABILITY Welcome to the MIDLAND Programming software! It s a programming software specifically designed for G14 and must be used in conjunction with the dedicated
More informationResistive Fault Location Methods REFERENCE GUIDE
Resistive Fault Location Methods REFERENCE GUIDE Table of Contents 1. RESISTIVE FAULT LOCATION... 1 1.1 WHAT IS IT?... 1 1.2 POTENTIAL RFL-RELATED ISSUES... 4 1.3 RFL TEST USING EXFO MAX/FTB-600 SERIES...
More informationFirmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.
LINE TESTER LT51 The LT51 Line Tester is a portable handheld battery powered instrument. It combines the features of several pieces of test equipment such as a Selective Level Meter / Spectrum Analyser,
More informationINDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6
ST-965 KW/D SMARTRUNK II & SMARTRUNK XPRESS Logic board Programming Software 2.9e User s Guide Revision R2.9.8 12/30/2008 INDEX INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3
More informationAN INTRODUCTION TO A NEW MICRO-REFLECTION LOCATION TECHNOLOGY
ADVANCED TECHNOLOGY AN INTRODUCTION TO A NEW MICRO-REFLECTION LOCATION TECHNOLOGY 185 AINSLEY DRIVE SYRACUSE, NY 13210 800.448.1655 / WWW.ARCOMDIGITAL.COM ADVANCED TECHNOLOGY AN INTRODUCTION TO AN ENTIRELY
More informationActerna DSL-311 and DSL-322 DSL Copper Testers
Acterna DSL-311 and DSL-322 DSL Copper Testers The increased demand for ISDN, highspeed data, and full-motion video puts extreme pressure on copper-based access networks designed for POTS. In fact, more
More informationFTB-610 Wideband Copper Test Module
FTB-610 Wideband Copper Test Module ADVANCED COPPER CABLE TESTER WITH SMARTR FAULT ANALYSIS Please note that this model has been discontinued. For more information, visit EXFO.com The easiest and smartest
More informationRigExpert AA-170 Antenna Analyzer (0.1 to 170 MHz) User s manual
RigExpert AA-170 Antenna Analyzer (0.1 to 170 MHz) User s manual Table of contents 1. Description... 3 2. Specifications... 4 3. Precautions... 5 4. Operation... 6 4.1. Preparation for use... 6 4.2. Turning
More informationINSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA1
INSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA FOREWORD Thank you for purchasing the RS-BA. The RS-BA is designed to remotely control an Icom radio through a network. This instruction manual contains
More informationRequirements and Test Methods for Very-High-Bit-Rate Digital Subscriber Line (VDSL) Terminal Equipment
VDSL(E) Issue 1 (Provisional) January 2003 Terminal Attachment Program Requirements and Test Methods for Very-High-Bit-Rate Digital Subscriber Line (VDSL) Terminal Equipment Aussi disponible en français
More informationMultiMaster. Base Station Test Tools. Multi Purpose Base Station Tester. Introduction. Feature
Introduction The GenComm is a comprehensive and cost effective solution for performing base station and repeater maintenance in any environment covering all CDMA Standards including cdmaone, cdma2000 1x
More information3 Tone Slope FINAL TEST using manual meter mode process 5 Point Test and COT Assistance
3 Tone Slope FINAL TEST using manual meter mode process 5 Point Test and COT Assistance These test results will not be captured in the EXP manager, but are the minimum requirements to close a ticket or
More informationOpternus GmbH. optische Spleiss- und Messtechnik. Tel. +49(0) Fax +49(0)
SMARTER COPPER TESTING FOR INSTALLATION TECHNICIANS Smarter verification of copper pairs and location of faults during the installation and repair of voice and DSL circuits. SPEC SHEET KEY FEATURES AND
More informationG7104A Multimaster Base Station Tester
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS G7104A Multimaster Base Station Tester Key features Multi-function integration The Multimaster has integrated all necessary functions to test and measure CDMA
More informationINDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6
ST-965 VX/D SMARTRUNK II & SMARTRUNK XPRESS Logic board Programming Software 2.9e User s Guide Revision R2.9 10/10/2008 INDEX INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3
More informationFaculty of Electrical & Electronics Engineering BEE4233 Antenna and Propagation. LAB 1: Introduction to Antenna Measurement
Faculty of Electrical & Electronics Engineering BEE4233 Antenna and Propagation LAB 1: Introduction to Antenna Measurement Mapping CO, PO, Domain, KI : CO2,PO3,P5,CTPS5 CO1: Characterize the fundamentals
More informationTesting Motorola P25 Conventional Radios Using the R8000 Communications System Analyzer
Testing Motorola P25 Conventional Radios Using the R8000 Communications System Analyzer Page 1 of 24 Motorola CPS and Tuner Software Motorola provides a CD containing software programming facilities for
More informationAXS-200/ MHz COPPER TEST SET. part of the SharpTESTER Access Line. Telecom Test and Measurement
30 MHz COPPER TEST SET AXS-200/610 part of the SharpTESTER Access Line NETWORK TESTING ACCESS Identify copper problems affecting triple-play quality Visual reports, graphs and histograms, displaying signal
More informationJDSU Presents The Cause and Effects of Bonding and Grounding on xdsl IPTV Services February 12 th, 2009
JDSU Presents The Cause and Effects of Bonding and Grounding on xdsl IPTV Services February 12 th, 2009 Jeff Harmon Account Manager Western Region Triple Play, Data/IP Analysis Solutions Office: 972 692-3705
More informationisys-4004 GUI interface - V2.1 Power up Initialize Peripheral Start Measurement YES LED flashes red Object available LED blinking
isys-4004 GUI interface - V2.1 Power up Initialize Peripheral Start Measurement Mode Object available YES LED flashes red NO LED blinking isys-4004 distance sensor GUI description content 1. connecting
More informationAPX Mobile and Portable Automated Test and Alignment
APX Mobile and Portable Automated Test and Alignment Software Updates First things first! Be sure to check that you are running the latest software versions for the 8800SX and its applications. Visit the
More information1.1 End-to-End Testing Conditions End2End Step-by-Step Local ATV-25 Remote ATV-25
1.1 End-to-End End-to-End (End2End) testing uses two test sets to confirm Tip and Ring continuity between 25 local pairs and 25 remote pairs. The test specifically checks to ensure that pair X of the local
More informationAgilent U1271A/U1272A Handheld Digital Multimeter. Quick Start Guide
Agilent U1271A/U1272A Handheld Digital Multimeter Quick Start Guide Verify that you received the following items in the shipment of your multimeter: One pair of red and black test leads One pair of 4 mm
More informationMicro Wizard Instructions
How to install FAST TRACK K3 4-digit actual times and 1-digit sequence of finish display timer with Computer Serial Interface Enclosed you will find the Fast Track finish line, AC adapter and remote start
More informationIC-400pro - RADIOAFICION.COM
PROCEDURES IC-400pro - 5- PREPARATION When you adjust the contents on pages 5-5 and 5-6, SOFT- WARE, the optional CS-400PRO ADJ SOFTWARE (Rev..0 or later), *OPC- JIG CABLE (modified OPC- CLONING CABLE;
More informationMicro Fox PicCon Manual
Micro Fox PicCon Manual Version 0.61 The Micro Fox PicCon (MF PC) is a 700mW fox hunting/hidden transmitter hunt transceiver. It can be configured and remotely controlled via DTMF tones, and also be configured
More informationGetting Started with TrangoLink
Getting Started with TrangoLink Overview: TrangoLink allows you to configure and monitor your EAGLE PLUS, FALCON, or PTZ-900 transmitters and receivers. On the EAGLE PLUS and FALCON transmitters, you can
More informationWPE 48N USER MANUAL Version1.1
Version1.1 Security instructions 1. Read this manual carefully. 2. Follow all instructions and warnings. 3. Only use accessories specified by WORK PRO. 4. Follow the safety instructions of your country.
More informationFLIR Tools for PC 7/21/2016
FLIR Tools for PC 7/21/2016 1 2 Tools+ is an upgrade that adds the ability to create Microsoft Word templates and reports, create radiometric panorama images, and record sequences from compatible USB and
More information"Terminal RG-1000" Customer Programming Software. User Guide. August 2016 R4.3
"Terminal RG-1000" Customer Programming Software User Guide August 2016 R4.3 Table of Contents Table of Contents Introduction 2 3 1.1 Software installation 3 1.2 Connecting the RG-1000 GATEWAYs to the
More informationUCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS
UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL UCORE ELECTRONICS www.ucore-electronics.com 2017 Contents 1. Introduction... 2 2. Turn on or turn off... 3 3. Oscilloscope Mode... 4 3.1. Display Description...
More informationTransmission Lines and TDR
Transmission Lines and TDR Overview This is the procedure for lab 2b. This is a one- week lab. The prelab should be done BEFORE going to the lab session. In this lab, pulse propagation down transmission
More informationMicro Wizard Instructions
How to install your Fast Track flashing light display timer model K1 with optional remote start switch (If you have ordered the Quick Mount or have a Best Track, disregard this section and refer to the
More informationAgilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide
Agilent U1273A/U1273AX Handheld Digital Multimeter Quick Start Guide Verify that you received the following items in the shipment of your multimeter: One pair of red and black test leads One pair of 4
More informationDIGITAL LINK MEASURING INSTRUMENTS MS371A/A1 GPIB PCM CHANNEL ANALYZER. For Simultaneous Measurement of 30 Channels with MS120A
PCM CHANNEL ANALYZER MS371A/A1 For Simultaneous Measurement of 30 Channels with MS120A (MS371A1) GPIB The MS371A/A1 is an overall measuring instrument with many measuring functions for digital primary
More informationSHDSL Time Domain Reflectometry Application Note
SHDSL Time Domain Reflectometry Application Note Revision History Revision Date Author Notes 1 9/26/2017 Stephen Ochs Initial SHDSL Time Domain Reflectometry Application Note Page 2 of 18 Table of Contents
More informationQuick Start Guide. RSP-Z2 Dual Channel Analog-IP Interface
INTEROPERABILITY NOW Quick Start Guide RSP-Z2 Dual Channel Analog-IP Interface Designed and Manufactured by: JPS Interoperability Solutions 5800 Departure Drive Raleigh, NC 27616 919-790-1011 Email: sales@jpsinterop.com
More informationLesson 3: Arduino. Goals
Introduction: This project introduces you to the wonderful world of Arduino and how to program physical devices. In this lesson you will learn how to write code and make an LED flash. Goals 1 - Get to
More informationBFoxCon Manual. Version 0.2 October 30, 2017
Overview The Byonics BFoxCon is a radio controller board designed to pair with a Baofeng UV-5R to create a transceiver for hidden transmitter hunts, also called T-hunts, foxhunts, and ARDF. It mounts on
More informationAntenna and Propagation
Antenna and Propagation This courseware product contains scholarly and technical information and is protected by copyright laws and international treaties. No part of this publication may be reproduced
More informationDecember 2012 Number Linearity Testing in the SureCAL Power Sensor Package FLEXIBLE STANDARDS ASSIGNMENT
Overview: December 2012 Number 201202 Linearity Testing in the SureCAL Power Sensor Package This Technical Note describes linearity testing utilized in the SureCAL Power Sensor Package for power sensors
More informationRCU-06 USER MANUAL. Introduction
RCU-06 USER MANUAL Introduction The following manual will show the features and how to use the new antenna electronic controller. As you will see, it is by far the most simple and intuitive controller
More informationGFL-1000 User Manual Ground Fault Locator
GFL-Series User Manual V1.1 GFL-1000 User Manual Ground Fault Locator Contents Contents... 1 1 Declaration of Conformity... 3 2 Introduction... 3 3 Equipment Information... 3 3.1 Safety Precautions...
More informationReview: The MFJ-225 Graphical Antenna Analyzer Phil Salas AD5X
Review: The Graphical Antenna Analyzer Phil Salas AD5X The has a back-lit 3 LCD graphic display that simultaneously shows the frequency or swept frequency range, unsigned complex impedance, impedance magnitude,
More informationA50/A51/A60. June 2008 (4th Edition) All Rights Reserved
A50/A51/A60 June 2008 (4th Edition) All Rights Reserved Part I - A50/A51 RS-232 to RS-422/RS-485 Converter A50/A51 RS-232 to RS-422/RS-485 Bidirectional Converter Part II - A60 RS-232 Surge Protection
More informationKeysight U1241C/ U1242C Handheld Digital Multimeter. Quick Start Guide
Keysight U4C/ U4C Handheld Digital Multimeter Quick Start Guide Safety Notices CUTION CUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly
More informationUSER AND INSTALLATION MANUAL
USER AND INSTALLATION MANUAL Software version 1.0.18 INSTALLATION MANUAL TABLE OF CONTENTS INTRODUCTION 2 WARNINGS 2 TECHNICAL SPECIFICATIONS 2 CONNECTION LAYOUT 3 ELECTRONIC CONNECTIONS 4 RS-485 LINE
More informationVersion 9.1 SmartPTT Monitoring
Version 9.1 SmartPTT Monitoring December 2016 Table of Contents Table of Contents 1.1 Introduction 2 1.2 Installation of the SmartPTT software 2 1.3 General SmartPTT Radioserver Configuration 6 1.4 SmartPTT
More informationInstruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1
Instruction Manual ABM HART Gateway Software Instruction Manual Revision A.1 Table of Contents Section 1: Getting Started... 3 1.1 Setup Procedure... 3 1.2 Quick Setup Guide for Ultrasonic Sensors... 11
More informationData Isolation Cards. 2-Wire HDSL/56KBS Isolation Card P Wire HDSL/56KBS Isolation Card P30050
Data Isolation Cards 2-Wire HDSL/56KBS Isolation Card P30076 4-Wire HDSL/56KBS Isolation Card P30050 Printed in USA 12/11 T0331 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT OVERVIEW 2 2.1 System
More informationCIC ENGINEERING 345 CENTER STREET EAST PEORIA, IL PH FAX µmpis Control Software
µmpis Control Software Overview The µmpis Control software package allows for a user to control the operation of the umpis unit with a PC. The PC and the umpis unit are connected together using a RS232
More informationIX Feb Operation Guide. Sequence Creation and Control Software SD011-PCR-LE. Wavy for PCR-LE. Ver. 5.5x
IX000693 Feb. 015 Operation Guide Sequence Creation and Control Software SD011-PCR-LE Wavy for PCR-LE Ver. 5.5x About This Guide This PDF version of the operation guide is provided so that you can print
More informationDisable Windows Sounds
9/28/2017 - K3CT Disable Windows Sounds Users may want to disable the Windows Sounds so none of the Windows OS sounds are transmitted on the radio. Install the Icom Drivers, Select COM port, Disable Power
More informationBench LCR Meter Model 891
Data Sheet Bench LCR Meter The 891 is a compact, precise, and versatile LCR meter capable of measuring inductors, capacitors, and resistors at DC or from 20 Hz to 300 khz. The instrument s 2U half-rack
More informationAirScope Spectrum Analyzer User s Manual
AirScope Spectrum Analyzer Manual Revision 1.0 October 2017 ESTeem Industrial Wireless Solutions Author: Date: Name: Eric P. Marske Title: Product Manager Approved by: Date: Name: Michael Eller Title:
More informationConfiguration Guide. Version 8.3
Capacity Plus Configuration Guide Version 8.3 Table of Contents 1 Table of Contents 1 Introduction 2 2 Brief Information on Use of Control Stations 4 3 6 3.1 Programming Repeter 7 3.1.1 Master Repeater
More informationU. S. ARMY TEST AND EVALUATION COMMAND COMMODITY ENGINEERING TEST PROCEDURE
Materiel Test Procedure 6-2-230 Electronic Proving Ground 1. OBJECTIVE U. S. ARMY TEST AND EVALUATION COMMAND COMMODITY ENGINEERING TEST PROCEDURE RADIO CONTROL EQUIPMENT 41 V The objective of this Materiel
More informationApplication Note: Testing P25 Conventional Radios Using the Freedom Communications System Analyzers
: Testing P25 Conventional Radios Using the Freedom Communications System Analyzers FCT-1007A Motorola CPS and Tuner Software Motorola provides a CD containing software programming facilities for the radio
More informationQuiver User Guide. Xcor-QUG-v /13/12
Quiver User Guide Xcor-QUG-v.3.0.4 8/13/12 This document details the full features and functionality of Quiver. Included is information on the various modes of operation and instruction on how to best
More informationOPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER
OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate
More informationTV SIGNAL LEVEL METER USER MANUAL
TV SIGNAL LEVEL METER USER MANUAL - 0 - 1. Overview (1) (1) RF input (2) (3) A D E B C (2) Speaker (3) LCD display (4) Charger indicator (5) RS232 communication port (6) DC-IN port F G A. The battery icon
More informationPC Tune PC Tune Test Procedures for 5100 Series Portable Radios
PC Tune PC Tune Test Procedures for 5100 Series Portable Radios Part Number 002-9998-6513014 August 2008 Copyright 2006, 2007, 2008 by EFJohnson Technologies The EFJohnson Technologies logo, PC Configure,
More informationLincView OPC USER GUIDE. Enhanced Diagnostics Utility INDUSTRIAL DATA COMMUNICATIONS
USER GUIDE INDUSTRIAL DATA COMMUNICATIONS LincView OPC Enhanced Diagnostics Utility It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of
More informationEVDP610 IXDP610 Digital PWM Controller IC Evaluation Board
IXDP610 Digital PWM Controller IC Evaluation Board General Description The IXDP610 Digital Pulse Width Modulator (DPWM) is a programmable CMOS LSI device, which accepts digital pulse width data from a
More informationM-Bus Master MultiPort 250L Installation and User Guide
Installation and User Guide Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: +45 89 93 10 00 info@kamstrup.com kamstrup.com Contents 1 Introduction 3 1.1 Design 3 2 Functionality 4 2.1 Overview
More informationDEC-001 Installation Instructions
DEC-001 Installation Instructions Skill Level: The installation of this assembly requires a medium level of expertise in working with modern electronic equipment. The use of appropriate tools, correct
More information990DSL. Users Guide. CopperPro Loop Tester. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Visit us at www.testequipmentdepot.com 990DSL CopperPro Loop Tester Users Guide Table of Contents Chapter Title Page 1 Introduction...
More informationConcept of Serial Communication
Concept of Serial Communication Agenda Serial v.s. Parallel Simplex, Half Duplex, Full Duplex Communication RS-485 Advantage over RS-232 Serial v.s. Parallel Application: How to Measure the temperature
More informationVersion 9.1 SmartPTT Enterprise. Installation & Configuration Guide
Version 9.1 SmartPTT Enterprise December 2016 Table of Contents Table of Contents 1.1 Introduction 3 1.2 Installation of the SmartPTT software 3 1.3 General SmartPTT Radioserver Configuration 7 1.4 SmartPTT
More informationTT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-
-Key Features- DS Instruments Power Meter 50 to 7000MHz Frequency Counter 100 to 7000MHz R4 RF Power Meter, Signal Generator, Frequency Counter Signal Generator 300 to 9600MHz Internal 31dB Step Attenuator
More informationCopperPro Series II. The complete test set for qualifying your local loop for ADSL, VDSL and special services.
99 Washington Street Melrose, MA 02176 Phone 7816651400 Toll Free 18005178431 Visit us at www.testequipmentdepot.com CopperPro Series II The complete test set for qualifying your local loop for ADSL, VDSL
More informationP a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.
P a g e 1 ST985 TDR Cable Analyzer Instruction Manual Analog Arts Inc. www.analogarts.com P a g e 2 Contents Software Installation... 4 Specifications... 4 Handling Precautions... 4 Operation Instruction...
More informationCopper Loop Frequency Management Plan
Copper Loop Frequency Management Plan Issue 8 Revision1.1 Issue 8 Revision 1.1 Keywords Access Network; Spectral Management; Document Details Version Control Issue Revision level Date Summary 1 0 8 th
More informationAgilent U1253B True RMS OLED Multimeter. Quick Start Guide
Agilent U1253B True RMS OLED Multimeter Quick Start Guide The following items are included with your multimeter: Silicone test leads 4 mm probes Alligator clips Printed Quick Start Guide Rechargeable 8.4
More informationDynatel 900 Series Subscriber Loop Test Sets
3 Provided by www.aaatesters.com Dynatel 900 Series Subscriber Loop Test Sets Optimal performance is a test you can t afford to fail. 1 Optimal loop performance is a key competitive advantage. Keep it
More informationChanging settings in the BlueSolar MPPT Charge Controllers
2016-11-21 07:40 1/14 Changing settings in the BlueSolar MPPT Charge Controllers Changing settings in the BlueSolar MPPT Charge Controllers DEPRECATED: Use VictronConnect instead of mpptprefs We recommend
More information