INTERPHONE SYSTEM-1 A HOME 2752-TYPE TELEPHONE SETS CONNECTIONS AND MAINTENANCE

Size: px
Start display at page:

Download "INTERPHONE SYSTEM-1 A HOME 2752-TYPE TELEPHONE SETS CONNECTIONS AND MAINTENANCE"

Transcription

1 BELL SYSTEM PRACTCES Plant Series SECTON ssue 2, November 1970 AT&TCo Standard NTERPHONE SYSTEM-1 A HOME 2752-TYPE TELEPHONE SETS CONNECTONS AND MANTENANCE 1. GENERAL 1.01 This section contains conversion and connection information for the 2752-type telephone set for use with 1A home interphone in conjunction with 3-type speakerphone. Connection information is also given for home interphone without speakerphone feature, but in such cases, it is recommended that the 2754-type telephone set be used This section is reissued to change section references in Operation with the 1A home interphone system requires installation of a 664B transmitter (ordered separately, Fig. 1). The loudspeaker circuit is controlled by the speakerphone control unit. With speakerphone OFF the speaker is connected to the interphone circuit; with speakerphone ON the speaker is transferred to the speakerphone circuit. The 3A cord reel shall be used when the telephone set is subjected to temperatures below 40 degrees F. The 3B cord reel shall be used when the telephone set is not subjected to temperatures below 40 degrees F. N2 TRANSMTTER UNT Fig Transmitter nstalled Table E-Conductor Assignments Using 75A Connecting Block or A25B Connector Cable Fig Type Telephone Set Connections, Wired For 1A Home nterphone Fig Type Telephone Set, Connections To 1A Home nterphone and 3-Type Speakerphone 2. CONNECTON NDEX 3. MANTENANCE Table A-Conversion of Telephone Set For 1A Home nterphone Table B-Pickup-Signal Key Conversion Table C-Ringer or Buzzer Connections Table D-Disconnecting Speakerphone Feature 3.01 Refer to Division 502 for maintenance information for the 2752-type telephone sets. Refer to Division 512 for home interphone system requirements and maintenance information Maintenance of the home interphone components of these sets (Fig. 1) is limited to replacement of defective units. American Telephone and Telepraph Company, 1970 Printed in U.S.A. Page 1 SSP 512-S10-4SO-i02_ l.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Apr 29, :16:04

2 SECTON TABLE A CONVERSON OF TELEPHONE SET FOR 1 A HOME NTERPHONE* TABLE B PCKUP-SGNAL KEY CONVERSON TEL SET LEADS REMOVE FROM CONNECT TO CONVERSON OPTONS Y-BR 635A2 KEY LEADS BR BR-BK (G-BK) 5R 1 Tel Set (l:lk-gl 5T 2 Plug (BR-Bl{) t DC2 Key (BR-BT() X 4T (W) :! TRMTR (R) 2 (Added) (S) DC! Convert 5th pickup key to signal (for door Hnswering). t Stored loeution. HPlPP(,)Sw M \[ 4T HPPSP(,)S,., M SG 4T HPSSP(,)S,., SG SG HPP S P(, )Sw an SG P(, )-Home intcrphone pickup ker S(A )-Door answering signal key Sec Note 2 Note&:. Convert 5th picku1> ker to signal (nonloeking) for door answering h_v removing the P-28E773 locking pin from plunger. 2. This option uses 2nd pickup key for private or intercommunicating line and 3rd key converted to signal -lt 4T TABLE C RNGER OR BUZZER CONNECTONS LEADS OPTON RNGER STRAP BUZZER R BK S-R ls BL R Bridged Ringer on any Line K T*.._ t t A to R* Common or Private Line Ringer or Buzzer With Capacitor Without Capacitor K A RT t t t RT t t t A to RR:j: A to RR:t: RR:j: RT Ringer Permanently Silenced K K t.._ t A to K *Terminal of line involved. tlnsulated and stored. :j:rr terminal on terminal board. Connect buzzer in place of ringer using twisted pair station wire. Page 2 SSP i02_ jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Apr 29, :16:19

3 SS 2, SECTON TABLE D DSCONNECTNG SPEAKERPHONE FEATURE (See Note) TEL SET COMPONENT LEADS SPEAKERPHONE COMPONENT LEADS TEL SET PLUG DAL SWTCH ASSEMBLY PRNTED WRNG BOARD Conductor color (V-G) (G-V) (V-S) (V) (Y-BL) (BL-Y) (0-Y) (Y-O) (S-Y) (S-BK Disconnect from* Tl Rl AG 7 s Fl Pl M2 M2 Ml *Terminals on telephone set terminal board. Note: When speakerphone feature of set is not required but set is multipled with a set providing speakerphone operation, disconnect, insulate and store these leads to avoid interference with working circuits. f interference continues, disconnect leads at multipling point as near as possible to speakerphone control unit. Page 3 SSP 512-S10-4SO-i02_ jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Apr 29, :16:34

4 SECTON PART OF KS , L1 PLUG STATON susj 1 LEAD DESGNATON AND WRE COLOR PART EXCLUSON PA RNGER OF SWTCH TERMNAL (NOTE BOARD SL V-SR SL (Y-BR) g 44 --=------= *--"" "-=- Tl T R V-G) (V SR (SR V) Tl " o 7 (OJ (V R (V SL [R] G R R SL V R A OR H V-01 1s2 (0-V 1: s 3 G OR SG R OR Rl SR Y (S Y (O W * R B4 SPEAKERPHONE [ 43 SYSTEM 18 HOME [1 3 NTERPHONE 14 SYS TEM 3 8 TO KTS 23 8 OR 81 SP2 SP Ml oc M2 A OR B R l Y S Y-G (G Y) G-SK SR SK SK G 10-W (G V) RT W.. (SK 52 Y-G LNE SWTCH Sl (W -S 4 (Y-S) m )1 (G-Y) * (OJ j BL kj EMS 0 2 * R (.1 S (Y b Q PMS (G d EM 3 T 6 OC2 OC er BK 9 S6 S-R S-SK Q 0 EB4 (S) r LOUDSPEAKER - " l-1-t -.,,--! SK BL W 6648 J101 TRMTR (NOTE 2) f-;cket.. S) (SK (SR W [W] BK W SL (RJ (V J TO SH 2 TO SH 3 16 SPEAKERPHONE SYSTEM Fl -. s M2 1. P i Ml BL Y Y BL S -V 10-Y (Y-O) Fl s M2 P Ml l f (SL-Y) Y SL W W (Y-O) 10-Y S Y S-BK OFF ON t::, (SL-W l G KEY AND VOLUME CONTROL [ ls 12 ls (V) 10 () 14 (BL-W) 1 3 GJ PART OF TERMNAL BOARD 1 l ;;-; h f -L J 1 CO- TRANSMTTER AND AMPLFER ---< G Fig Type Telephone Set Connections (Sheet 1 of 3) Page 4 BSP i02_ JP& Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Apr 29, :16:48

5 (Y-BRJ (OJ V! (R) [\}j 2L2 BKJ ll L SS 2, SECTON G3K HANDSET 40OD NETWORK 35C3A DAL 3-TYPE CORD REEL (NOTE 3) w [R) [W) (R) (Rl (Rl TO s,, _._.,.":J" r ,J j{ ri"v; r-+----,l u -4 #t k.r.:-- F ; &; l R G v t w 1 e TO SH [W) (BK) CORD REEL U!!! ::ac (!)--a:: - i :J -o- RCVR, TRMTR!!. S) (BK) BR) W [W) (BK) (W- BL) RJ NOTES:. REFER TO APPROPRATE SECTON N DVSON 502 FOR EXCLUSON SWTCH CONNECTONS F REQURED. Z. CONNECT 6648 TRANSMTTER (ORDERED SEPARATELY} AS SHOWN N TABL E A. 3. ( ] DENOTES 3A CORD REEL LEAD COLORS. ( ) DENOTES 38 CORD REEL LEAD COLORS. * NSULATED AND STORED t NOT USED N HOME NTERPHONE SYSTEM 0 TERMNAL WTH SCREW Q TERMNAL WTHOUT SCREW Fig Type Telephone Set Connections (Sheet 2 of 3) Page 5 BSP i02_ QS.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Apr 29, :17:06

6 ... SECTON PART OF K$ 16671, Lt PLUG LEAD DESGNATON AND W RE COLOR 6 3 5A2 KEY SPEAKER PHONE 50 SYSTEM t HOLD KEY H LNE LNE AND 2 CRCUT SGNAL ll A OR H t W -0) H :1- o J - t-7 " "..J " 2 1ST LNE PCKUP KEY )----- P) --i@i f L G- W --j j ----f G -- - W W G J LG tw-gl hlw %t1 R (BA - Wl }]!i 2R tbr-wl 2ND LNE PCKUP KEY )---- P LNE AND 3 SGNAL 32 CRCUT 1 2R ts - Rl lffu 4R (5-Rl 1 :== ==:H: : i == ========== ::=::= K ) *.lj -1 2T R :_ -.::l:" : ) ii! l f :(")-<o - L - G >---,---.-,vi\ PHONE r;:;":fm " ffl :tii! l f --- X-<:"O::! --._ ---S)-" f--7 3 N.; (;CKUP 36 2 BK - Bll ):;):: 4 H (BK-Bl HOME 12 NTER- 37 SYSTEM PHONE lki OR,..,_ G-BK ;. :.... l.."...» ihj.... l 6 t.. L4 0 O LG4!.@ rv [4 5T m:j {BR 3 --t - BKl mg sw (BK-BR) tlm 5H (BK BR) : ---ll fffi!j!-- : ---"-" "s"-_ "" ","----ll j,*:j; <0> ,"s""- -.=.,-----?) o, 4 J c L df (BK S) PM (BK-Sl - G ---ii :e;-- t " ; _, " : "" :-----ii HU ;:*: l--l, _, " ; "- ; J G 4, s Fig Type Telephane Connectians (Sheet 3 af 3) Page 6 SSP 512-S10-4SO-i02_ jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Apr 29, :17:22

7 SS 2, SECTON PART OF 050AA MTG cooo PART OF 70A CONN BlOCK 20 : : :=:], NSDE WRE OR CABlE NOTE U " t "f PR! 1 {NOTE PR 3) li 11!., A COHT ROL UN T 2ft 2T oc 5W Ml " {NOTE 3) rw QUAD 730A RECEVER (DOOR ANSWER UNT) 558 CONTROL UNT NOTE 5) 55A* CONTROL UNT CONNECT TO A OR LOCAL GR N (NO 4 1.!! t ,. 47 H,. J PR ADD STRAPS M 1-.,=i-,_,.:...., 53 {NO 2) - W PR A- 54 (Yl CBKJ 201ZA OR KS W PR TRNSF P ::l "[;j" 6" J TRNSF CPOWER) NOTE 5) NOTts:. NTERCONNECTONS MAY BE MADE USNG AN A25B CONNECTOR CABlE WHEN THE 5/A AND 55-TYPE CONTROl UNTS ARE located AT THE KEY EQUPMENT. Z. CONNECT R2 4 AS SHOWN WHEN ONLY ON 130A RECEVER S USED. 3. SPEACER leads MUST BE CONNECTED AS SHOWN FOR COMMON SYSTEM USE. 4. MUST 8 CONNECTED TO A WHEN USED WTH /A Olt A2 KEY TELEPHONE SYSTEM. 5. F SPEAKERPHONE FEATURE S NOT PROVDED, CONNECT SPEAKER LEADS FROM!lA CONTROL UNT DRECT TO 75A CONNECTNG BLOCK TERMNALS 3!1 AND 36); DSREGARD ALL CONNECTONS SHOWN FOR 55-TYPE CONTROL UNT. (]) TERMNAL WTH SCREW 0 TERMNAL WTHOUT * THE 55A CONTROL UNT MUST BE MODFED FOR USE WTH THE TOUCH-TONE DAL EQUPPED SETS. MODFED UNTS ARE DENTFED BY AN ASTERSK FOLLOWNG THE CODE. Fig Type Telephone Set, Connections to 1A Home lnterphone ond 3-Type Speakerphone Page 7 BSP S i02_ jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Apr 29, :17:40

8 SECTON TABLE E CONDUCTOR ASSGNMENTS USNG 75A CONNECTNG BLOCK OR A25B CONNECTOR CABLE TELEPHONE SET A2SB CONNECTOR CABLE OR 7SA CONNECTNG CONNECTONS DSOAA-3 MOUNTNG CORD* BLOCK LEAD PLUG TEL SET PAR CONNECTOR CONDUCTOR TERMNAL lyj CABLE DESG. PN NO. TERMNAL NO. PN NO. COLOR NO. CONDUCTOR T 2li T 26 1\"-BL l W-BL H H BL-\\ 2 BL-\\" 1\ nr 1l 27 lll 27 W-0 :! \V-0 2 A nr B 2 H 2 0-\V 2 0-\V L(:J 28 (llt Ll :l (l)t :! O-W (j G-\\- T 2H 2T 29 \V-BR 7 W-BR 4 R 4 21l 4 BR-\\ 8 BR-W A, -1, or S :10 2l 5 :!0 \\"-8 9 W-S :l 28 W-C 5 W-G B.5 t 5 S-\\ 10 S-\Y LG2 :ll (2lt :ll R-BL R-RL 6 L2 li (2)t 6 BirR 12 BL-R T :l2 :n :32 R-0 13 R-0 i R 7 :m i 0-lt 14 0-R A, H, or S :J:l :lh R-G 15 lt-g 8 ll 8 t 8 C-R 16 C-t LO:l (:llt 3 ll-blt 17 R-Bil u L:l! (:l)t!) Bll-ll l8 BR-R 2T :!5 n 35 H-S (!) R-S 10 2H 10.m 10 S-ll 20 S-R None :!6 411 Sparo t BL-BK 22 BL-BK None :li (-l)t :!7 BK-0 23 llk-0 12 None 12 (l)t 12 0-BK 2-l 0-BK :18 lll-g 25 BK-C 13 ll J :l U-HR 26 G-llK :l!j 5H 3!) UK-t 27 HK-BR 14 DC 1-l OC2 1-l BR-BK 28 Bit-lK S\\" :H BK-BL 21 BK-BL NonP.jl) (5)t,ll BK-S 2U BK-S 15 Non< 15 l!i H-BK 30 S-BK s 41 s -ll Y-BL 31 Y-BL 16 Fl lfi Fl i B!,-Y :!2 BL-Y 42 \ 42 :J.l Y-U li P i 17 0-Y :H 0-Y Sl2 t:l S2 -l:l Y-G Y-G 18 SP 18 H 18 G-Y :lu 0-Y BL H UL Y BR 19 G or SO 1!1 SG!) BH-Y as Bll-Y B or H -15 RT Y-S :J!) Y-S 20 R or ll 20 RR 20 S-Y -lo S-Y T 46 ET -lti V-BL -ll V-BL 2 1 R 21 EH 2 1 BL-V 42 BL-V A or Ell -li V-0-13 V-0 22 B 22 EB 22 0-V H 0-V T -18 Tl 48 V-G 45 V-G 2:3 H. 2:! Rl 2:3 G-V -16 G-V T 4n s.j!) V-BR -17 V-BR 24 m 24 i 24 BR-V -18 BR-V At: 50 A<: 50 V-S 4!1 V-S :\-V 50 S-V 47 (5) t Y-J 44 Y-llR Terminl1t< spt de-tipped c ondurtors of 050AA-:J mounting cord on the 75A connecting blork " indicated. t Numhers in parentheses denotp c onnprtions to LG and. terminals of key plugs as follows : ()-Blue, (2)-0range, (:J)-Green, (4)-Brown, (:i)-slate. t Tnsulated and stored :l7 Page 8 8 Pages BSP i02_ jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Apr 29, :17:54

SERVICE 2565HK AND 2565HKM TELEPHONE SETS

SERVICE 2565HK AND 2565HKM TELEPHONE SETS BELL SYSTEM PRACTCES AT&TCo Standard ssue 6, October 1975 SERVCE 565HK AND 565HKM TELEPHONE SETS 1. GENERAL 1.01 This section provides connection information for the 565HK and 565HKM telephone sets. 1.0

More information

SERVICE. 1. GENERAL 661A3 the appropriate key must be separately ordered and installed. For ordering and installing

SERVICE. 1. GENERAL 661A3 the appropriate key must be separately ordered and installed. For ordering and installing BELL SYSTEM Plant Series PRACTCES SECTON 502-67-40 ssue, December 970 AT&TCo Standard SERVCE 66-TYPE TELEPHONE SETS. GENERAL 66A3 the appropriate key must be separately ordered and installed. For ordering

More information

SERVICE 2565HK AND 2565HKM TELEPHONE SETS

SERVICE 2565HK AND 2565HKM TELEPHONE SETS BEU SYSTEM PRACTCES AT & TCo Standard SECTON -54-405 ssue 7, November 1977 SERVCE 565HK AND 565HKM TELEPHONE SETS 1 GENERAL 101 This section provides connection information sets (Fig 1) for the 565HK (MD)

More information

TELEPHONE SETS 881A102, , 881C102, 881A103, , 881C103, 881A104, , AND 881C104

TELEPHONE SETS 881A102, , 881C102, 881A103, , 881C103, 881A104, , AND 881C104 BELL SYSTEM PRACTCES AT & TCo Standard SECTON 53-2-18 ssue 3, January 1978 TELEPHONE SETS 881A12, 881812, 881C12, 881A13, 881813, 881C13, 881A14, 881814, AND 881C14 1. GENERAL 1.1 This section provides

More information

SERVICE 2564HL, 2564HLM, AND 2564HLMS TELEPHONE SETS MAINTENANCE AND CONNECTIONS

SERVICE 2564HL, 2564HLM, AND 2564HLMS TELEPHONE SETS MAINTENANCE AND CONNECTIONS BELL SYSTEM PRACTCES AT&TCQ Standard SECTON 52-543-42 ssue 6, Noember 98 SERVCE 2564HL, 2564HLM, AND 2564HLMS TELEPHONE SETS MANTENANCE AND CONNECTONS. GENERAL.O This section contains information for the

More information

TELEPHONE SETS 910A AND 2910A IDENTIFICATION, INSTALLATION, AND CONNECTIONS

TELEPHONE SETS 910A AND 2910A IDENTIFICATION, INSTALLATION, AND CONNECTIONS BELL SYSTEM PRACTCES AT&TCo Standard SECTON 503-200-101 luue 1, April 1974 TELEPHONE SETS 910A AND 2910A DENTFCATON, NSTALLATON, AND CONNECTONS 1. ENERAL 1.01 This section provides identification, installation,

More information

4A SPEAKERPHONE SYSTEM

4A SPEAKERPHONE SYSTEM BELL SYSTEM PRACTCES AT&TCo Standard SECTON 512-7-lOD ssue 2 September 1974 4A SPEAKERPHONE SYSTEM \ 1. DENTFCA TiON 1.1 The 4A speakerphone system is a hands-free voice switched system for use as a telephone

More information

BELL SYSTEM PRACTICES Plant Series

BELL SYSTEM PRACTICES Plant Series BELL SYSTEM PRACTCES Plant Series SECTON 58469MS ssue B, August, 963 M. S. T. & T. Co. CON COLLECTOR TELECART dentification, nstallation and Maintenance. DENTFCATON. The Coin Collector Telecart consists

More information

AUXILIARY SIGNALS IDENTIFICATION, INSTALLATION, OPERATION, MAINTENANCE, AND CONNECTIONS

AUXILIARY SIGNALS IDENTIFICATION, INSTALLATION, OPERATION, MAINTENANCE, AND CONNECTIONS BELL SYSTEM PRACTCES AT& TCo Standard SECTON 463-11 0-1 00 ssue 12, October 1979 AUXLARY SGNALS DENTFCATON, NSTALLATON, OPERATON, MANTENANCE, AND CONNECTONS 1. GENERAL 1.01 This section provides information

More information

INTERCONNECTING DEVICES COMMON EQUIPMENT 75A CONTROL UNIT

INTERCONNECTING DEVICES COMMON EQUIPMENT 75A CONTROL UNIT BSP 463-300-112-i01_1973-11.01.jpg Scanned by Frank Harrell (CowboyFrank) Castle Rock. Colorado Feb 23.2016 21:15:56 BELL SYSTEM PRACTCES AT&TCo Standard SECTON 463-300-112 ssue 1, November 1973 NTERCONNECTNG

More information

4A SPEAKERPHONE COMPONENTS. IDENTIFICA lion, INST ALLA lion, OPERA lion, AND MAINTENANCE

4A SPEAKERPHONE COMPONENTS. IDENTIFICA lion, INST ALLA lion, OPERA lion, AND MAINTENANCE BELL SYSTEM PRACTICES AT& TCo Standard SECTION 512-700-100 Issue 5, April 1979 4A SPEAKERPHONE COMPONENTS IDENTIFICA lion, INST ALLA lion, OPERA lion, AND MAINTENANCE 1. GENERAL 1.01 This section contains

More information

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS BELL SYSTEM PRACTICES Plant Series SECTION 500-150-1 00 Issue 6, April 1970 AT&TCo Standard RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS 1. GENERAL 1.01 This section contains information on the reduction

More information

SERVICE SPECIAL SAFEGUARD MEASURES SPECIAL SERVICE PROTECTION RADIO AND TELEGRAPH LOOPS

SERVICE SPECIAL SAFEGUARD MEASURES SPECIAL SERVICE PROTECTION RADIO AND TELEGRAPH LOOPS BELL SYSTEM PRACTCES Plant Series SECN 460-11 0-400 ssue 1, December 1969 AT & TCo Standard SERVCE SPECAL SAFEGUARD MEASURES SPECAL SERVCE PROTECN RADO AND TELEGRAPH LOOPS 1. GENERA L 1.01 This section

More information

REFERENCE INDUCTIVE NOISE

REFERENCE INDUCTIVE NOISE BELL SYSTEM PRACTCES AT&TCo StCindard SECTON 500-12-100 luue 8, January 1973 REFERENCE NDUCTVE NOSE ENERAL 101 This section contains information to control and minimize the effects of inductive noise at

More information

MATRIX BLOCK-1 A 1 IDENTIFICATION, INSTALLATION, WIRING, AND MAINTENANCE I

MATRIX BLOCK-1 A 1 IDENTIFICATION, INSTALLATION, WIRING, AND MAINTENANCE I ELL SYSTEM PRACTCES AT&TCo Stondord ssue 2, December 1971 MATRX LOCK-1 A 1 DENTFCATON, NSTALLATON, WRNG, AND MANTENANCE 1. GENERAL 1.01 This section provides identification, installation, wiring and maintenance

More information

SERVICE 565HK, 565HKM, AND 565HKMS TELEPHONE SETS CONNECTIONS

SERVICE 565HK, 565HKM, AND 565HKMS TELEPHONE SETS CONNECTIONS BEU SYSTEM PRACTCES AT & TCo Standard SECTON 502-541-4 1 5 ssue 8, February 1980 SERVCE 565K, 565KM, AND 565KMS TELEPONE SETS CONNECTONS 1. GENERAL 1.01 This section contains information for the 565K (MD),

More information

VOICE CONNECTING ARRANGEMENTS QKT AND QKTBT 30-TYPE VOICE COUPLER

VOICE CONNECTING ARRANGEMENTS QKT AND QKTBT 30-TYPE VOICE COUPLER BSP 463-311-100-i05_1974.Q3.Q1.jpg Scanned by Frank Harrell (CowboyFrank) Castle ock. Colorado Feb 23,2016 21:24:32 BELL SYSTEM PACTCES AT&TCo Standard SECTON 463-311-100 ssue 5, March 1974 VOCE CONNECTNG

More information

r--- INSIDE WIRE CABLE

r--- INSIDE WIRE CABLE Scanned b Frank Harrell, (Cowbo Frank) Castle Rock, Colorado Oct 09, 01 14:6 :"ol. BELL SYSTEM PRACTICES Plant Series SECTION 461-60-1 00 Issue 1, January 1968 AT&TCo Standard CONNECTING BLOCKS 4A, 44A,

More information

21 A COMMUNICATION SYSTEM (COM KEY* 2152)

21 A COMMUNICATION SYSTEM (COM KEY* 2152) BELL SYSTEM PRACTCES AT & TCo Standard SECTON 518-450- 11 0 ssue 1, December 1976 21 A COMMUNCATON SYSTEM (COM KEY* 2152) CONTENTS PAGE CONTENTS PAGE Multiline Pickup 33 1. GENERAL 2 Hold and llumination

More information

4A SPEAKERPHONE SYSTEM

4A SPEAKERPHONE SYSTEM BELL SYSTEM PRACTCES AT & TCo Standard SECTON 512-700-100 ssue 4, May 1978 4A SPEAKERPHONE SYSTEM 1. GENERAL 1.01 This section contains identification, installation, operation, and maintenance information

More information

DATA SET 109B TYPE DESCRIPTION

DATA SET 109B TYPE DESCRIPTION BELL SYSTEM Plant Series PRACTCES SECTON 312-802-100 ssue 1, December 1967 AT&TCo Swdard DATA SET 109B TYPE DESCRPTON 1. GENERAL 1.01 This section describes Data Set 109B type (109B1 and 109B2) physically

More information

CONNECTING BLOCKS 66-TYPE TOOLS, TERMINATING, ADAPTERS, AND MAINTENANCE. (5) Tighten screw.

CONNECTING BLOCKS 66-TYPE TOOLS, TERMINATING, ADAPTERS, AND MAINTENANCE. (5) Tighten screw. BELL SYSTEM PRACTICES AT&TCo Standard SECTION 461-604-100 Issue 2, August 1971 CONNECTING BLOCKS 66-TYPE TOOLS, TERMINATING, ADAPTERS, AND MAINTENANCE 1. GENERAL 1.01 Reissued to add information on 183B2

More information

* * * * * * * * * INSTALLATION AND MAINTENANCE

* * * * * * * * * INSTALLATION AND MAINTENANCE .-- )., TYPE CCRP RECTFERS * * * * * * * * * NSTALLATON AND MANTENANCE SERVCE MANUAL 595 CONTENTS Page... V. v. V. TABLE... V. NTRODUCTON..... DESCRPTON. OPERATON... A. NPUT VOLTAGE... B. CHARGNG BATTERES..

More information

COMMON AUDIBLE SIGNALING KEY TELEPHONE SYSTEMS

COMMON AUDIBLE SIGNALING KEY TELEPHONE SYSTEMS BELL SYSTEM PRACTICES AT & TCo Standard SECTION 518-0 1 0-1 08 Issue 3, October 1976 COMMON AUDIBLE SIGNALING KEY TELEPHONE SYSTEMS 1. GENERAL 1.01 This section provides a general description of common

More information

AUXILIARY SIGNALS IDENTIFICA lion

AUXILIARY SIGNALS IDENTIFICA lion BELL SYSTEM PRACTCES AT& TCo Standard SECTON 463-110-100 ssue 10, Odober 1974 AUXLARY SGNALS DENTFCA lion 1. GENERAL 1.01 This section provides identification, installation, operation, maintenance, and

More information

REFERENCE 1 A 1 KEY TELEPHONE SYSTEM. "TOUCH-TONE n ADAPTERS

REFERENCE 1 A 1 KEY TELEPHONE SYSTEM. TOUCH-TONE n ADAPTERS BELL SYSTEM PRACTICES AT&TCo Standard Issue 2, September 1971 REFERENCE 1 A 1 KEY TELEPHONE SYSTEM "TOUCH-TONE n ADAPTERS 1. GENERAL 1.01 This section is reissued to change relay designation H3 to L3 for

More information

KS TELETRAINER DESCRIPTION AND MAINTENANCE

KS TELETRAINER DESCRIPTION AND MAINTENANCE BELL SYSTEM PRACTICES AT&TCo Standard SECTION 473-411-100 Issue 4, January 1973 KS-16605 TELETRAINER DESCRIPTION AND MAINTENANCE 1. GENERAL 1.01 This section covers the description and maintenance of the

More information

28G AND G-1 ELECTRICAL SERVICE UNITS

28G AND G-1 ELECTRICAL SERVICE UNITS 19 American Telehone and Telegrah Comany Printed in U.S. A. BELL SYSTEM PRACTCES Teletyeriter and Data Station SECTON P. ue, February, 19 AT&TCo Standard G AND G-1 ELECTRCAL SERVCE UNTS WRNG DAGRAM 1.

More information

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS IDENTIFICATION, INSTALLATION, AND MAINTENANCE

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS IDENTIFICATION, INSTALLATION, AND MAINTENANCE AT & T PRACTICE Standard AT & T 500-150-100 Issue 11, July 1984 RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS IDENTIFICATION, INSTALLATION, AND MAINTENANCE 1. GENERAL 1.01 This practice contains information

More information

DESIGNATION STRIPS AND CARDS

DESIGNATION STRIPS AND CARDS BELL SYSTEM PRACTCES AT& TCo Sandard SECTON 501-150-1 02 ssue 5, March 1978 DESGNATON STRPS AND CARDS 1. GENERAL 1.01 Designaion srips and cards are used o indicae on which key or pushbuon a paricular

More information

AUXILIARY KHZ PILOT SUPPLY TESTS

AUXILIARY KHZ PILOT SUPPLY TESTS BELL SYSTEM PRACTCES SECTON 356-011-505 AT&TCo Standard ssue 1, June 1971 L MULTPLEX COMMON TERMNALS EQUPMENT AUXLARY 31592-KHZ PLOT SUPPLY TESTS An auxiliary 31592-kHz pilot supply (Fig 1) provides pilot

More information

REFERENCE 500E/F, 500H, 500L/M, 500P, 500R/S, 500U, 500W, 500Y, 500AD, 501F, 501P, 501U, 5148, AND 5168 TELEPHONE SETS

REFERENCE 500E/F, 500H, 500L/M, 500P, 500R/S, 500U, 500W, 500Y, 500AD, 501F, 501P, 501U, 5148, AND 5168 TELEPHONE SETS BELL SYSTEM PACTCES AT&TCo Standard SECTON 52-51-115 ssue 2, May 1971 EFEENCE 5E/F, 5H, 5L/M, 5P, 5/S, 5U, 5W, 5Y, 5AD, 51F, 51P, 51U, 5148, AND 5168 TELEPHONE SETS 1 ENEAL 11 This section provides identification,

More information

E2 STATUS REPORTING AND CONTROL SYSTEM STATUS DESCRIPTION

E2 STATUS REPORTING AND CONTROL SYSTEM STATUS DESCRIPTION BELL SYSTEM PRACTCES AT&TCo Standard SECTON 20-644-4 ssue, April 975 E2 STATUS REPORTNG AND SYSTEM STATUS REPORTNG REMOTE DESCRPTON.,i) ~:.:..?,. 2. 3. 4. CONTENTS GENERAL.......... PHYSCAL DESCRPTON.....

More information

TWO-POINT PRIVATE LINE TELEPHONE CIRCUITS TEST PROCEDURES

TWO-POINT PRIVATE LINE TELEPHONE CIRCUITS TEST PROCEDURES BELL SYSTEM PRACTCES SECTON 310-300-500 AT&TCo Standard ssue 7, June 1975 TWO-PONT PRVATE LNE TELEPHONE CRCUTS VOCE ONLY TEST S 1. CONTENTS GENERAL...........1 PAGE always be referred to for TLP levels,

More information

BACKBOARDS IDENTIFICATION AND INSTALLATION

BACKBOARDS IDENTIFICATION AND INSTALLATION &ELL SYSTEM PRACTICES AT&TCo Standard SECTION 463-130-1 00 Issue 10, December 1971 BACKBOARDS IDENTIFICATION AND INSTALLATION 1 GENERAL 101 This section provides information on common use backboards Refer

More information

DATA SETS 1 08D- AND 1 08E-TYPES SINGLE PRIVATE LINE STATION ARRANGEMENT USING DATA AUXILIARY SET 820D TEST PROCEDURES

DATA SETS 1 08D- AND 1 08E-TYPES SINGLE PRIVATE LINE STATION ARRANGEMENT USING DATA AUXILIARY SET 820D TEST PROCEDURES BELL SYSTEM PRACTCES AT&TCo Stondard. GENERAL 2. TEST EQUPMENT CARRER MONTORNG TEST A. Far-End Carrier B. Near-End Carrier CARRER SHFT TEST LOOP-BACK TEST DATA SETS 1 08D- AND 1 08E-TYPES SNGLE PRVATE

More information

METALLIC FACILITY TERMINAL LOOP-START AND GROUND-START TO DX OR E&M SIGNALING CONVERTERS (J99343FA, FB, FC, AND FD)

METALLIC FACILITY TERMINAL LOOP-START AND GROUND-START TO DX OR E&M SIGNALING CONVERTERS (J99343FA, FB, FC, AND FD) BELL SYSTEM PRACTCES AT&TCo Standard ssue 1, November 1979 METALLC FACLTY TERMNAL LOOPSTART AND GROUNDSTART TO DX OR E&M SGNALNG CONVERTERS (J99343FA, FB, FC, AND FD) NSTALLATON AND TESTNG,. CONTENTS PAGE

More information

STATION DIALS 1. GENERAL. SECTION (15 Issued: 21 February 1974, Standard

STATION DIALS 1. GENERAL. SECTION (15 Issued: 21 February 1974, Standard NORTHERN ELECTRC PRACTCES r----f-il-in-g--ns-t-r-uc-t-io-n-s-:------.. GENERAL.0 This section contains identification maintenance and connection information for NE-35Q'type DGTONE* dials that are used

More information

KEY TELEPHONE UNIT 237-TYPE IDENTIFICATION, OPERATION, AND CONNECTIONS

KEY TELEPHONE UNIT 237-TYPE IDENTIFICATION, OPERATION, AND CONNECTIONS ELL SYSEM PACCES A&Co Standard SEC 518310407 ue 8, May 1974 KEY ELEPHE UN 237YPE DENFCA, OPEA, AND CNECS 1. GENEAL 1.01 hi ection i reiued to: Delete Speakerphone Sytem No. la and lal connection Add Speakerphone

More information

February Superfast Surrey - Gainshare Deployment Postcodes

February Superfast Surrey - Gainshare Deployment Postcodes February 2017 - Superfast Surrey - Gainshare Deployment Postcodes It MUST be noted that the status of any Gainshare deployment postcode in this spreadsheet may change after BT have undertaken detailed

More information

BURIED PLANT -BURIED WIRE TERMINATIONS

BURIED PLANT -BURIED WIRE TERMINATIONS BELL SYSTEM PRACTICES AT & TCo Standard SECTION 460-300-143 Issue 3, April 1978 BURIED PLANT -BURIED WIRE TERMINATIONS CONTENTS PAGE Information on E armored service wire 1. GENERAL 2. DISPOSITION OF UNTERMINATED

More information

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS BELLSYSTEM PRACTICES SECTION500-150-11X) AT&TCo Standard Issue 7, January 1974 RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS 1. GENERAL Transistors in amplifiers of some networks and handsets 1.01 This section

More information

COMMON AUDIBLE SIGNALING KEY TELEPHONE SYSTEMS

COMMON AUDIBLE SIGNALING KEY TELEPHONE SYSTEMS AT & TCo Standard SECTON 518-010-108 ssue 5, November 1980 COMMON AUDBLE SGNALNG KEY TELEPHONE SYSTEMS 1. GENEAL 1.01 This section provides a general description of common audible signaling arrangements,

More information

SERVICE 1 A2 KEY TELEPHONE SYSTEM KEY SERVICE UNITS 550- AND 551-TYPE

SERVICE 1 A2 KEY TELEPHONE SYSTEM KEY SERVICE UNITS 550- AND 551-TYPE BELL SYSEM PRACCES A & Co Standard SECON 5825407 ssue, uly 976 SERVCE A2 KEY ELEPHONE SYSEM KEY SERVCE UNS 550 AND 55YPE. GENERAL.0 his section provides identification, installation, connection, and maintenance

More information

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS BELL SYSTEM PRACTICES Plant Series SECTION 500-150-1 00 Issue 6, April 1970 AT&TCa Standard RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS 1. GENERAL 1.01 This section contains information on the reduction

More information

INPUT AND OUTPUT POWER ADJUSTMENTS PRIMARY FREQUENCY CONVERTER LMX-1 AND 13 CARRIER ANALOG MULTIPLEX TERMINAL EQUIPMENT

INPUT AND OUTPUT POWER ADJUSTMENTS PRIMARY FREQUENCY CONVERTER LMX-1 AND 13 CARRIER ANALOG MULTIPLEX TERMINAL EQUIPMENT BEU SYSTEM PRACTCES SECTON 356-165-501 A7&TCa Standard ssue 4, May 1980 NPUT AND OUTPUT POWER ADJUSTMENTS PRMARY FREQUENCY CONVERTER LMX-1 AND 13 CARRER ANALOG MULTPLEX TERMNAL EQUPMENT This section explains

More information

4-WIRE ORDER CIRCUIT TESTS

4-WIRE ORDER CIRCUIT TESTS (a) Frequency: 1 khz (b) Power: Between -40 dbm and + 10 dbm NOTICE Not for use or disclosure outside the Bell System except under written agreement Printed in U.S.A. Page 1 BELL SYSTEM PRACTICES AT &

More information

POLYTECHNIC UNIVERSITY Electrical Engineering Department. EE SOPHOMORE LABORATORY Experiment 1 Laboratory Energy Sources

POLYTECHNIC UNIVERSITY Electrical Engineering Department. EE SOPHOMORE LABORATORY Experiment 1 Laboratory Energy Sources POLYTECHNIC UNIERSITY Electrcal Engneerng Department EE SOPHOMORE LABORATORY Experment 1 Laboratory Energy Sources Modfed for Physcs 18, Brooklyn College I. Oerew of the Experment Ths experment has three

More information

150-BAUD PRIVATE LINE CHANNELS

150-BAUD PRIVATE LINE CHANNELS BELL SYSTEM Plant Series PRACTCES SECTON 32-0-0 ssue, JUY 970 AT&TCo Standard 50-BAUD PRVATE LNE CHANNELS NTERFACE SPECFCATONS. DESCRPTON GENERAL.0 The purpose of this specification is to define the interface

More information

Visit rswww.com/branches for information and the latest news from your local RS.

Visit rswww.com/branches for information and the latest news from your local RS. Down the road or across the country, you re never far from the products you need. Visit rswww.com/branches for information and the latest news from your local RS. Follow us on twitter @RSLocal YOUR LOCAL

More information

1. REVIEW 2. DELIVERY SET

1. REVIEW 2. DELIVERY SET power status ON steps DIP test reset ON DIP off modes lght sensor / led sensor speed on sensor 2 speed off on/off delay pause to off REVIEW LED lghtng devce s desgned for automatc lghtng of starway steps

More information

JACKS AND PLUGS IDENTIFICATION AND SERVICE

JACKS AND PLUGS IDENTIFICATION AND SERVICE BELL SYSTEM PRACTICES AT&TCo Standard SECTION 461-630-1 00 Issue 9, March 1976 JACKS AND PLUGS IDENTIFICATION AND SERVICE 1. GENERAL 1.01 This section provides identification, installation, and service

More information

NDRpa/C I I SQUARED CDMPRNY. Solid State Logic Control. CONTENTS Description. Pages. FILE: Control Products Catalog

NDRpa/C I I SQUARED CDMPRNY. Solid State Logic Control. CONTENTS Description. Pages. FILE: Control Products Catalog NDRpa/C Solid State Logic Control FLE: Control Products Catalog CONTENTS Description Pages Encapsulated nput & Output Devices.................. 2 Encapsulated Logic Devices................................

More information

STYLE F-40A DC/DC CONVERTER MAINTENANCE INSTRUCTIONS Suitable for Outdoor Mounting) * * * * * * * * * * * (N )

STYLE F-40A DC/DC CONVERTER MAINTENANCE INSTRUCTIONS Suitable for Outdoor Mounting) * * * * * * * * * * * (N ) An American-Standard Company.. SERVCE MANUAL 5799 (Not STYLE F-40A DC/DC CONVERTER MANTENANCE NSTRUCTONS Suitable for Outdoor Mounting) * * * * * * * * * * * (N451033-0801) Description The Style F-40A

More information

AT&T SERVICE MANUAL. PagePac VS (AT&T VERSION) INSTALLATION

AT&T SERVICE MANUAL. PagePac VS (AT&T VERSION) INSTALLATION AT&T SERVICE MANUAL PagePac VS (AT&T VERSION) INSTALLATION AT&T SERVICE MANUAL PagePac* VS INSTALLATION SM 722994 004 Issue 1, *Registered Trademark of Harris Corporation Dracon Division Copyright HARRIS

More information

Trade marketing Bespoke look book

Trade marketing Bespoke look book Trade marketing Bespoke look book Terms & conditions. Lorem ipsum dolor sit amet, consectetuer adipiscing elit, sed diam nonummy nibh euismod tincidunt ut laoreet dolore magna aliquam erat volutpat. REF:

More information

INSTRUCTIONS INTRODUCTION

INSTRUCTIONS INTRODUCTION Westinghouse. L. 41-912. 5 NSTALLATON OPERATON MANTENANCE NSTRUCTONS TYPES HKB/TCU - SKB/TCU & SKBU RELAYS NTRODUCTON This instruction leaflet describes the overall functioning of HKB/TCU, SKB/TCU and

More information

nstallation EasamPhon& Key Telephone System IIll~lllll! llllllllll llllllllll llllllllll

nstallation EasamPhon& Key Telephone System IIll~lllll! llllllllll llllllllll llllllllll nstallation EasamPhon& Key Telephone System ll~lllll! llllllllll llllllllll llllllllll 1. :.: : CONTENTS. 1. HOW TO FOLLOW THE NSTALLATON PROCEDURE... 1 2. PACKNG MATERALS AND EXPLODED VEW... 2 2.1 PACKNG

More information

Strain Gauge Measuring Amplifier BA 660

Strain Gauge Measuring Amplifier BA 660 Stran Gauge Measurng Amplfer BA 660 Orgnal of the Manual BA660 / IP20 BA660 / IP66 Table of Contents 1. Safety precautons...2 1.1. Feld of applcaton...2 1.2. Installaton...2 1.3. Mantenance...2 2. Functon...2

More information

ATP-4 600/900 OHM DC BYPASS UNIT, AND ATP-5 BYPASS TEST UNIT

ATP-4 600/900 OHM DC BYPASS UNIT, AND ATP-5 BYPASS TEST UNIT BELLSYSTEM PRACTCES SECTON 3391101 AT&TCe Skmdad ssue, August 198! w J9933BA, BB, AND BC WRE TRANSMSSON UNTS, ATP 600/900 OHM DC BYPASS UNT, AND ATP5 BYPASS TEST UNT DESCRPTON f METALLC FACLTY TERMNAL

More information

CARRIER TRANSMISSION MAINTENANCE SYSTEM (CTMS) HOT TONE SCAN (HTS) AND QUICK HOT TONE SCAN (QHTS)

CARRIER TRANSMISSION MAINTENANCE SYSTEM (CTMS) HOT TONE SCAN (HTS) AND QUICK HOT TONE SCAN (QHTS) BELLSYSTEM PRACTCES AT& TCa Sttmdard SECTON 356-010-556 ssue 2, November 1976 L MULTPLEX COMMON TERMNALS EQUPMENT CARRER TRANSMSSON MANTENANCE SYSTEM (CTMS) HOT TONE SCAN (HTS) AND QUCK HOT TONE SCAN (QHTS)

More information

FLEX2 VERSION ALLFLEX 2 LEG / 3 SECTION HEIGHT ADJUSTABLE DESK **PATENT PENDING**

FLEX2 VERSION ALLFLEX 2 LEG / 3 SECTION HEIGHT ADJUSTABLE DESK **PATENT PENDING** FLEX2 ALLFLEX 2 LEG / 3 SECTON HEGHT ADJUSTABLE DESK VERSON A NSTRUCTON MANUAL CONTENTS: FLEX-MU-2L3S-C3672-K4# FEET-ADJ-UNV-2430# V1 **PATENT PENDNG** MAX Load 265 lbs (120 KG) Equally Divided MAX Load

More information

SENSOTEC UNIVERSAL INLINE TRANSDUCER AMPLIFIER BIPOLAR VOLTAGE MODEL. $!}~ f?(' 7. ()ept 1200 CHESAPEAKE AVE" COLUMBUS OHIO (614)

SENSOTEC UNIVERSAL INLINE TRANSDUCER AMPLIFIER BIPOLAR VOLTAGE MODEL. $!}~ f?(' 7. ()ept 1200 CHESAPEAKE AVE COLUMBUS OHIO (614) UNVERSAL NLNE TRANSDUCER AMPLFER BPOLAR VOLTAGE MODEL SENSOTEC 1200 CHESAPEAKE AVE" COLUMBUS OHO 43212 (614) 486-7723 $!}~- 822-7f?(' 7 )Rf/ f//ce ()ept 008-0295-00 Universallnline Transducer Amplifier

More information

SERVICE AND TYPE TELEPHONE SETS CONNECTIONS AND MAINTENANCE

SERVICE AND TYPE TELEPHONE SETS CONNECTIONS AND MAINTENANCE BESYSTEM PRACTCES A7&TCo Standard SECTON 02-61201 ssue 7, September 1980 SERVCE 2630- AND 2631 -TYPE TEEPHONE SETS CONNECTONS AND MANTENANCE 1. GENERA 1.01 This section contains information for the 2630DA

More information

Writing Folder Tools. {for K-2}

Writing Folder Tools. {for K-2} Writing Folder Tools {for K-2} Hey there teaching friend Enjoy these writing folder materials for K-2 These supports have helped my students become more independent writers, and I hope they do the same

More information

Style FR HI Shunt Track Unit

Style FR HI Shunt Track Unit I UNION SWITCH & SIGNALlimt 645 Russell Street Batesburg, SC 29006 Service Manual 5966 Style FR HI Shunt Track Unit Installation, Operation and Maintenance July, 1980 1980, Union Switch & Signal Inc. Printed

More information

L CARRIER TYPE COAXIAL CABLE PREPARATION AND COMPLETION TESTS

L CARRIER TYPE COAXIAL CABLE PREPARATION AND COMPLETION TESTS . -.. BELL SYSTEM PRACTCES SECTON 330-200-501 Plant Series ssue 1, November 1969 AT&TCo Standard CABLE TESTNG L CARRER TYPE COAXAL CABLE PREPARATON AND COMPLETON TESTS 11 AND 13 COAXAL CONDUCTORS 1. 1.

More information

Array E System Grounding Philosophy. This ATM briefly describes modifications to system grounding

Array E System Grounding Philosophy. This ATM briefly describes modifications to system grounding Array E System Grounding Philosophy NO. ATM-962 PAGE 1 REV. NO. OF 14 DATE This ATM briefly describes modifications to system grounding philosophy from those applied on previous flights and provides system

More information

Cross-Connect Interface

Cross-Connect Interface Cross-Connect Interface User Manual Document #: 050-015-0036R01 November 2006 TASC Systems Inc. Langley, BC Canada Cross-Connect System User Manual Preface This document describes the installation, commissioning

More information

Parameter Symbol Value Unit

Parameter Symbol Value Unit *RoHS OMPLINT VRSIONS VILL eatures Lead free versions available RoHS compliant (lead free version)* Surface Mount SM package Standoff Voltage: 5. to 17 volts Power issipation: 6 watts 214 Transient Voltage

More information

EQUIPMENT LIST. Prepared by: Product Marketing Department Gates Radio Company Quincy, Illinois WITH FOR AM BROADCAST STATION 250 WATT TRANSMITTER

EQUIPMENT LIST. Prepared by: Product Marketing Department Gates Radio Company Quincy, Illinois WITH FOR AM BROADCAST STATION 250 WATT TRANSMITTER EQUPMENT LST FOR AM BROADCAST STATON WTH 250 WATT TRANSMTTER Prepared by: Product Marketing Department Gates Radio Company Quincy, llinois kw, n preparing this guide for the selection of equipment for

More information

Time allowed TWO hours plus 15 minutes reading time

Time allowed TWO hours plus 15 minutes reading time ICPA: Introductory Certificate in Patent Administration Mock Examination 2017/18 Course Time: as agreed with your mentor INSTRUCTIONS TO CANDIDATES This examination pack comprises: Time allowed TWO hours

More information

MODEL CM-30. Technical Practice November 2002 Issue 4. Service Observing System 1. GENERAL 2. DESIGN FEATURES CONTENTS: Model CM-30

MODEL CM-30. Technical Practice November 2002 Issue 4. Service Observing System 1. GENERAL 2. DESIGN FEATURES CONTENTS: Model CM-30 Model CM-30 Technical Practice November 2002 Issue 4 MODEL CM-30 Service Observing System 1. GENERAL 1.01 The DEES CM-30 is a complete 30 line service observing system with integrated talk assist capability.

More information

KS DIALER SWITCHBOARD AND MISCELLANEOUS KEY EQUIPMENT CONNECTIONS

KS DIALER SWITCHBOARD AND MISCELLANEOUS KEY EQUIPMENT CONNECTIONS SYST PCTCS Plant Serie SCTO 51212543 ue 2, December 197 T&TCa Standard S19594 D SWTCOD D SCOUS Y QUPT COCTOS 1. 1.1 Thi ection i reiued to: echange connection termination of dialer telehone cord at equiment,

More information

Literacy Curriculum Puzzles

Literacy Curriculum Puzzles About the series Literacy Curriculum Puzzles is a series of bks of photocopiable worksheets designed for pupils at Key Stage and into the ely terms of Key Stage who need extra support to develop basic

More information

E-400 endstufe. user manual

E-400 endstufe. user manual E-400 endstufe user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0)9546 9223-66 email: info@thomann.de Internet: www.thomann.de 02.12.2011 Table of contents Table

More information

E-400 power amplifier. user manual

E-400 power amplifier. user manual E-400 power amplifier user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: (09546) 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 07.03.2014, ID: 173888 Table

More information

TELEPHONE SETS 701, 702, AND 711 TYPES INSTALLATION

TELEPHONE SETS 701, 702, AND 711 TYPES INSTALLATION BELLSYSTEM PRACTICES SECTION 502-710-200 Plant Series Issue 3, January, 1963 AT&TCo Standard TELEPHONE SETS 701, 702, AND 711 TYPES INSTALLATION 1.00 INTRODUCTION 2.00 GENERAL 1.01 This section covers

More information

LLC STRANG ADVANCE LLC

LLC STRANG ADVANCE LLC NOTIONS TAGS and more FOR ALL APPLICATIONS SA LLC STRANG ADVANCE LLC 139 BRICK CHURCH ROAD SPRING VALLEY, NY 10977 Phone: 845.354.9516 Fax: 845.290.6338 Web: safetypinswholesale.com * E-Mail: info@ safetypinswholesale.com

More information

1\. power 3A speakerphone systems.

1\. power 3A speakerphone systems. BELL SYSTEM PRACTICES AT&TCo Standard SECTION 501-136-100 Issue 5, May 1972 STATION TRANSFORMERS IDENTIFICATION 1. GENERAL 1.01 This section is reissued to: Include KS-20426L3 transformer Change Read,

More information

75A-4 MODIFICATION FOR BUSHIPS. The purpose of this supplement is to show the changes in the 75A-4

75A-4 MODIFICATION FOR BUSHIPS. The purpose of this supplement is to show the changes in the 75A-4 75A-4 MODFCATON FOR BUSHPS GENERAL The purpose of this supplement is to show the changes in the 75A-4 nstruction Book (Collins part number 520 5052 00) necessary to make it agree with the-changes made

More information

No.Sl. NATIONAL RADIO ASTRONOMY OBSERVATORY Charlottesville, Virginia. January 2 2, i986. Rack and Module Plan for VLBA Electronics

No.Sl. NATIONAL RADIO ASTRONOMY OBSERVATORY Charlottesville, Virginia. January 2 2, i986. Rack and Module Plan for VLBA Electronics NATONAL RADO ASTRONOMY OBSERVATORY Charlottesvlle, Vrgna January 2 2, 986 To: VLBA Electroncs Group Proms Dck Thompson Subject: Rack and Module Plan for VLBA Electroncs The VLBA electroncs subsystems that

More information

7A COMMUNICATION SYSTEM"-COM KEY*"718 KEY TELEPHONE SYSTEM DESCRIPTION, ORDERING INFORMATION, AND OPERATION

7A COMMUNICATION SYSTEM-COM KEY*718 KEY TELEPHONE SYSTEM DESCRIPTION, ORDERING INFORMATION, AND OPERATION BEU SYSTEM PRACTICES AT&TCo Standard SECTION 518-450-1 00 Issue S, February 1982 7A COMMUNICATION SYSTEM"-COM KEY*"718 KEY TELEPHONE SYSTEM DESCRIPTION, ORDERING INFORMATION, AND OPERATION CONTENTS PAGE

More information

c. Battery Charger c Volt Supply TL MICROWAVE RADIO DESCRIPTION POWER SUPPLY H. Battery Voltage Alarm Circuit.

c. Battery Charger c Volt Supply TL MICROWAVE RADIO DESCRIPTION POWER SUPPLY H. Battery Voltage Alarm Circuit. BELL SYSTEM PRACTCES Plant Series 2. OPERATNG PRNCPLES CONTENTS PAGE B. Klystron Supply Regulator and nverter. D. Battery Voltage Alarm Circuit. 3. CRCUT DESCRPTON. A. Klystron Supply Regulator and nverter.

More information

NOTE FTDX9000 CAT OPERATION REFERENCE BOOK FTDX9000 OPERATING MANUAL

NOTE FTDX9000 CAT OPERATION REFERENCE BOOK FTDX9000 OPERATING MANUAL NTE FTD9000 CAT PERATIN REFERENCE BK FTD9000 PERATING MANUAL CAT (CMPUTER AIDED TRANSCEIVR) PERATIN VERVIEW The CAT (Computer Aided Transceiver) System in the FTD9000 provides control of frequency, VF,

More information

DRAWINGS ON 35MM MICROFILM FOR INSTALLATION AND TELEPHONE COMPANY. EQUIPMENT MAINTENANCE lw. & [ : qp i

DRAWINGS ON 35MM MICROFILM FOR INSTALLATION AND TELEPHONE COMPANY. EQUIPMENT MAINTENANCE lw. & [ : qp i BE1l SYSTEM PRACTCES AT&TCo Standard SECTON 006-101-100 ssue 2, June 1978 DRAWNGS ON 35MM MCROFLM FOR NSTALLATON AND TELEPHONE COMPANY ----- -.._ -. _ tr, L / ~ / ;,/\ ~: ;< EQUPMENT MANTENANCE lw. & [

More information

CLASSIC SERIES PRICE LIST 18.1 Recommended retail price

CLASSIC SERIES PRICE LIST 18.1 Recommended retail price CLASSIC SERIES PRICE LIST 18.1 Recommended retail price CLASSIC SERIES Soldering Pencil Soldering Irons Temperature-controlled Soldering Iron Soldering Iron with Solder Feed 14ST 30ST 40ST 65ST SL 2020

More information

Halton (Milton) LRO #20

Halton (Milton) LRO #20 Miscellaneous KH Bankruptcy April 7, 1921 Sept 18, 1922 1 1452 BL Bylaws Nov 13, 1855 Sept 23, 1960 1 778 DH Deposits Oct 31, 1894 Sept 30, 1966 1 5088 GR General Register Jan 9, 1866 Sept 1, 1955 1 8276

More information

Absco Space Saver Shed Assembly Instructions Model: 23081SK

Absco Space Saver Shed Assembly Instructions Model: 23081SK Assembly Instructons Model: 2308SK FRONT BASE LENGTH: 2.26m SIDE BASE LENGTH: 0.78m FRONT WALL HEIGHT:.80m REAR WALL HEIGHT:.95m CONCRETE SLAB 880mm 2360mm WHEN LAYING YOUR CONCRETE SLAB, CHAMFER THE 50mm

More information

Insertion/Extraction Tool and Replacement Tip Kits [ ]

Insertion/Extraction Tool and Replacement Tip Kits [ ] Inserton/Extracton Tool 91285-1 and Replacement Tp Kts 543382-[ ] Instructon Sheet 408-9404 19 JUN 12 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually powered

More information

AMPLIFIER PLUG-IN UNIT FOR TYPE "EL" CODED CAB SIGNAL EQUIPMENT

AMPLIFIER PLUG-IN UNIT FOR TYPE EL CODED CAB SIGNAL EQUIPMENT SERVCE MANUAL 5682-G Description, Operation and Maintenance AMPLFER PLUG-N UNT FOR TYPE "EL" CODED CAB SGNAL EQUPMENT Part Number N339646-001 June, 1977 (Revised July, 1984) 100073C-DN0383 B-7/84-50-1211-1

More information

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 457B Seven Port Active Twinax Star Hub An ISO-9001 Certified Company Part #07M457B-C Doc. #069011UC Revised 4/22/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

More information

400W, 5V - 188V Surface Mount Transient Voltage Suppressor

400W, 5V - 188V Surface Mount Transient Voltage Suppressor 400W, 5V - 188V Surface Mount Transient Voltage Suppressor FEATURES Low profile package Ideal for automated placement Glass passivated junction Built-in strain relief Excellent clamping capability Fast

More information

~ SERVICE SPECIFICATION SU-4583 ~

~ SERVICE SPECIFICATION SU-4583 ~ .. WABCO SERVCE SPECFCATON SU-4583 STYLE F-50 NVERTER FOLLOWER UN451033-0701 1. General This service specification covers the testing and maintenance procedures for the Style F-50 nverter Follower. The

More information

PRICE LIST 17.1 Classic Series. Recommended Retail Price in

PRICE LIST 17.1 Classic Series. Recommended Retail Price in PRICE LIST 17.1 Classic Series Recommended Retail Price in CLASSIC SERIES Soldering Pencil Soldering Irons Temperature-controlled Soldering Iron Soldering Iron with Solder Feed 14ST 30ST 40ST 65ST SL 2020

More information

JACKS AND PLUGS IDENTIFICATION AND SERVICE

JACKS AND PLUGS IDENTIFICATION AND SERVICE BSP 461-630-100-i10_1979-02 01.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 09, 2012 15:14:23 BELL SYSTEM PRACTICES AT & TCo Standard SECTION 461-630-1 00 Issue 10, February 1979

More information

Absco Space Saver Shed Assembly Instructions Model: J30082S

Absco Space Saver Shed Assembly Instructions Model: J30082S Assembly Instructons FRONT BASE LENGTH: 9ft-0-7 64n SIDE BASE LENGTH: ft-6-45 64n FRONT WALL HEIGHT: 5ft-0-55 64n REAR WALL HEIGHT: 6ft-4-49 64n ft-0-4 64n CONCRETE SLAB 0ft--3 64n CONCRETE SLAB WHEN LAYING

More information

REGISTRATION INTERFACE BRIDGED MULTIPLE TIP AND RING ARRANGEMENTS

REGISTRATION INTERFACE BRIDGED MULTIPLE TIP AND RING ARRANGEMENTS BELL SYSEM PCCES & Co Provisional SECON -00-10 ssue, pril 1 1. GENEL 1.01 his section provides information on the standard wiring arrangements to be provided under the Federal Communications Commission

More information

BELLSYSTEM PRACTICES SECTION AT&TCo Standard Issue 7, November 1979 IDENTIFICATION

BELLSYSTEM PRACTICES SECTION AT&TCo Standard Issue 7, November 1979 IDENTIFICATION BELLSYSTEM PRACTICES SECTION 501-136-100 AT&TCo Standard Issue 7, November 1979 STATION TRANSFORMERS IDENTIFICATION 1 GENERAL unit to be in close proximity to the ac line source is not recommended. 1.01

More information

NATIONAL RADIO ASTRONOMY OBSERVATORY Green Bank, West Virginia ELECTRONICS DIVISION INTERNAL REPORT NO. 2

NATIONAL RADIO ASTRONOMY OBSERVATORY Green Bank, West Virginia ELECTRONICS DIVISION INTERNAL REPORT NO. 2 NATIONAL RADIO ASTRONOMY OBSERVATORY Green Bank, West Virginia ELECTRONICS DIVISION INTERNAL REPORT NO. 2 THE ELECTRON BEAM PARAMETRIC AMPLIFIER By DEWEY ROSS and ROBERT HAAS SEPTEMBER 1962 NUMBER OF COPIES:

More information