BELL SYSTEM PRACTICES Plant Series

Size: px
Start display at page:

Download "BELL SYSTEM PRACTICES Plant Series"

Transcription

1 BELL SYSTEM PRACTCES Plant Series SECTON 58469MS ssue B, August, 963 M. S. T. & T. Co. CON COLLECTOR TELECART dentification, nstallation and Maintenance. DENTFCATON. The Coin Collector Telecart consists of a coin collector and a telephone set built into a portable cabinet, for use by convalescent and bedridden patients in military hospitals and convalescent homes.. 2 The telecart is provided with a fiftyfoot cord which can be plugged into standard tele phone jacks, and is equipped with special mercury switches to prevent unauthorized return of coins.. 3 The cabinet, illustrated in Figure, has a frame of extruded aluminum, and side and top panels of gray laminated plastic. The wheels are equipped with heavyduty ball bearings for easy rolling.. 4 The Coin Collector is concealed in a front compartment of the cabinet. The coin slots (A) project above the top and the coin return pull bucket (B) projects through a hole in the door of the compartment. Operation of button (C) depresses the switchhook to release a nickel held by the holding latch. A coin release button (D) in the front panel is used to release coins wedged in the coin slots. A frame (E) for an instruction card is provided on top near the coin slots. FGURE Coin Collector Telecart Front View Page TC Library

2 SECTON 58469MS. 5 The reverse side of the cabinet contains two compartments: one to store the extension cord, the other to mount the control equipment illustrated in Figures 2 and 3. Equipment is mounted on the inside of the door, the left side panel and the rear panel of this compartment. The door is equipped with a regular upper housing lock from a coin collector.. 6 The parts list is shown in Table. FGURE 2 Coin Collector Telecart Equipment Co mpartment TABLE TELECART, COLLECTOR, CON PARTS LST Page 2 QUAN ft. NAME Switch, Mercury, G. E. 252 KRO, or equivalent SC K. T. U. (Key Telephone Unit) 8A K. T. U. U 3 Covers Relay, Ul 245 Relay, Yl7 Relay, Amperite, 26C2 Socket, Tube, Amphenol 77MP8, or equivalent 42A CONN BLK 44A CONN BLK Batteries, KS7889 Resistor, KS849, Ll, 47 ohms, 5% watt or equivalent (Figure 7) Lock, Coin Collector, OH. (Figure 2) Collector, Coin, 2 33GR 3 (Figure 6) Set, T e lephone, 5 DR 6 (Figure 4) Cord, D6AA6 l, 9Ft. (Figure 4) Cord, l 8Ga., 4 Cond., Type SO (6V), WhitneyBlake 5722, or equivalent (Figure 7) Plug, 283B9 (Figure 7) T elecart, Model 23C. Frame, Card, P l 4E388 TC Library

3 SECTON MS MERCURY,..._...,. SWTCH 53 8C KTU /w U t '245 RELAY "J (C) U3 COVER C, ac KTU Y 7 RELAY ] U3 COVER,Q AMPERTE@ Tl MER. 26C'2 77MP 8 4'2A /':i\ CONN ~ BLOCK. MERCURY,..._...,. SWTCH 54 TERMNAL LUGS CABLE. HOLE. 44A CONN BK. C C, SAK.TU CONN BK. 3 KS7889 r BATTERES 46!i V (A) (B) (C) 46.SV 46.SV 46.SV NSDE OF DOOR LEFT SDE PANEL RE.AR. PANEL FGURE 3 Equipment Compartment Page,3 TC Library

4 SECTON 58469MS 2. NSTALLATON 2. The telecart is shipped ready for service except for the following minor operations: (a) nstall instruction card in frame provided in top of cabinet. (b) Connect battery by attaching wire to ter minal of the 44A connecting block. This wire is left detached to avoid draining the battery in case of accidental operation of the mercury switches during shipping. There is normally no drain on the battery except intermittently when the telephone is in use. (c) Plug cord into standard telephone jack. 3. CRCUT DESCRPTONS, TESTS AND MANTENANCE 3. 2 The 5 type telephone used with the Telecart is modified as follows: a. Rewired as illustrated in Figure 4. b. Cord replaced with D 6AA6 cord, 9' long. The ringer is connected in the regular manner The Tele cart is equipped with a 233GR coin collector modified as follows: a. Dial and handset and associated wiring removed. b. Upper housing rewired as shown in Figure 6. c. Coin relay modified as shown in Figure 5 below. 3. Refer to appropriate sections of BSP' s for instructions on maintenance of the coin collector and telephone set..5tandard MOD/Fl~O n ra.f WDQ wo4 FGURE 5 Modification of Coin Relay Spring Assembly Page 4 TC Library

5 SECTON 58469MS 44A CONN BLOCK ~~{: LL C ~"{: ~ CORD (D6AA6) ~DDEO LEAD. :r~~ ~t oll /G \lk n... : L 2... ~,~F~ ; ' 6._L++:J.% ;:; r O ~ ~ o/ 7 DAL.. za ' T ~~ rl, u~ ~~ /\N< ) GN l ~~ >;.J RR, ~ U) ~ ""\.!2ilr ~ ~,7 ~ ~ > ; b SL SR d_ w r+ e ~ ~ w \. SL._R, o ++t.. ~~, "c ' ~ N, 6 R, s L BK ~ +r f) L_ / j 9 ~ w ' w R (. / BK tga HANDSET a tc ::i: FGURE. 4 5 D TYPE TELEPHONE. MOD Fl ED FOR USE W TH TELE CART Page 5 TC Library

6 uj T z R l o UC) :::, '<;f... Oa. 'o:;t CD U)rn (J) (X) UJN 4 COND z ri. TYREX ~o CA T (GREEN)...l.. G,. )...,..._ 3 6 ~ :x: u 3: ct l/) ~ ~ 4~ 45 R (RE:D) 'p""' N}.() ct ' :::, NU r~ ( G (WHTE) Tl G BLACK) 52 r =27 6 _ t 2...,, 3 4 l 3 4 5T,.) "' Pr 3 6T.... ~ ( p T V V PT ll'\... ) z o o... ~!i ~ 5 _, o '2 ~~, L j (A) U '245 (NORMALLY CLOS&D) ~; ~ SEE NOTE 2 NOTE5: S o, T }TO 5 TYPE. _. L TELE.PHONE r~ 4 7 g_ 2 s' ( FGURE 4) _.,,,,,Y 7 a 3? / «_8 5T.!!! D.2 c 4B.t, 3 :? _, ri ', 3 L.J (B) Y7,~ (NORMALLY OPE.N) 53 ~. BEWARE OF HGH VOLTAGE OF A, B $ C BATTE R ES, '2. THE MERCURY SWTCHES 52 AND 54 (NORMALLY CLOSED) SHOULD. FULLY OPEN BEFORE. SWTCHES S AND 53 (NORMALLY OPEN)CLOSE. 3. THE ELECTROMAGNET WLL FOLLOW DAL PULSES; DO NOT TRY TO READJUST. T FGURE. AMPERTE 26C2 (BOTTOM VEW) \ OF SOCK.ET 7 TELECART CONTROL Cl RCUT ~, r, ELECTRO MAGNET......J SEE NOTE3 ===~= +~ ~ : Ro.;.A~ R W R. ljl ~ '<:i ct ~ Ul C)... BK BKX VlJ6./ L j ::.l. Q UPPER HOUSNG CON. RE L,AY SEE A2,~3 Fl~URE: R L B BK)( C 2( = c... LCON_COLLECTO~ YELl ow l _ ' RED (,..,A GREEN r BLACK SECTON 58469MS G Al,r,~.:;.;;,. V FGURE 6,, r\.. 7 l )s : '..l4.,/. / B J COi N COLLECTOR MODFED FOR USE WTH TELE.CART 2Y. A.J 3 R V ' V lo L / CAUTON: SEE NOTE C V Page 6 TC Library

7 SECTON 58469MS 3. 4 The Telecart Control Circuit shown in Figure 7 prevents fraudulent or accidental return of coins which, without this circuit, will occur either when the cart is tilted or when the plug is removed from the jack before the coins are collected. Circuit requirements are shown in Table 2. TABLE 2 CRCUT REQUREMENTS APPARATUS DRECT CURRENT FLOW REQ i CKT i TEST TEST TEST DESG CODE. FG! WDG FOR AFTER SOAK MA MA READJ MA A Ul245 2 p s B! Yl5 2 p. ' l! i i H R l! l The circuit consists mainly of two relays and two pairs of mercury switches which control the operation of the telecart under various conditions. Condition A Normal Operation (Receiver offhook and coin deposited.) (See Figure 6 and Figure 7). Battery A operates relay (A) through the bottom contacts 2 & 3 of relay (B), mercury switches S2 and S4 and the coin relay contact. The operation of relay (A) connects the coin relay winding to line through top contacts 3 & 4 of relay (A). The coin collector operates normally from this point. Condition B 2. Relay {A) releases when coin contact opens through return or collection of coins. Plug Removed from Jack before Coin is Collected l. Relay (A) releases when lead G is opened. 2. Relay (B) operates, energized by A battery. Operation of relay (B) re moves the coin relay winding from the line and connects it through the Ampe rite Timer to A, B & C batteries in series, thus collecting coins. 3. Amperite Timer operates after /2 second, releasing the coin relay, which in Page 7 TC Library

8 SECTON 58469MS Condition C turn releases relay (B). Cart Tilted to Cause Premature Release of Coins The circuit operates normally with mercury switches S2 and S4 closed and S and S3 open. Tilting the cart in one direction causes switch S2 to open and switch Sl to close; tilting in the other direction causes switch S4 to open and switch S3 to close.. Cart tilted before coin is deposited. open, gong transmitter cannot transmit "coin release" signal. 2. Cart tilted after coin is deposited. With coin relay operated, tilting cart causes relay (A) to release, relay (B) to operate, and coins to be collected as in B and B2 above. The slow release of relay (B) through operation of the Amperite Timer ensures collection of the coins even though the cart is levelled quickly. When coin is deposited, relay (B) operates, causing the coin to be collected as in B2 above. With the line Page 8 8 Pages TC Library

TELEPHONE SETS 881A102, , 881C102, 881A103, , 881C103, 881A104, , AND 881C104

TELEPHONE SETS 881A102, , 881C102, 881A103, , 881C103, 881A104, , AND 881C104 BELL SYSTEM PRACTCES AT & TCo Standard SECTON 53-2-18 ssue 3, January 1978 TELEPHONE SETS 881A12, 881812, 881C12, 881A13, 881813, 881C13, 881A14, 881814, AND 881C14 1. GENERAL 1.1 This section provides

More information

KS TELETRAINER DESCRIPTION AND MAINTENANCE

KS TELETRAINER DESCRIPTION AND MAINTENANCE BELL SYSTEM PRACTICES AT&TCo Standard SECTION 473-411-100 Issue 4, January 1973 KS-16605 TELETRAINER DESCRIPTION AND MAINTENANCE 1. GENERAL 1.01 This section covers the description and maintenance of the

More information

INTERPHONE SYSTEM-1 A HOME 2752-TYPE TELEPHONE SETS CONNECTIONS AND MAINTENANCE

INTERPHONE SYSTEM-1 A HOME 2752-TYPE TELEPHONE SETS CONNECTIONS AND MAINTENANCE BELL SYSTEM PRACTCES Plant Series SECTON 512-510-450 ssue 2, November 1970 AT&TCo Standard NTERPHONE SYSTEM-1 A HOME 2752-TYPE TELEPHONE SETS CONNECTONS AND MANTENANCE 1. GENERAL 1.01 This section contains

More information

SERVICE. 1. GENERAL 661A3 the appropriate key must be separately ordered and installed. For ordering and installing

SERVICE. 1. GENERAL 661A3 the appropriate key must be separately ordered and installed. For ordering and installing BELL SYSTEM Plant Series PRACTCES SECTON 502-67-40 ssue, December 970 AT&TCo Standard SERVCE 66-TYPE TELEPHONE SETS. GENERAL 66A3 the appropriate key must be separately ordered and installed. For ordering

More information

SERVICE 2565HK AND 2565HKM TELEPHONE SETS

SERVICE 2565HK AND 2565HKM TELEPHONE SETS BELL SYSTEM PRACTCES AT&TCo Standard ssue 6, October 1975 SERVCE 565HK AND 565HKM TELEPHONE SETS 1. GENERAL 1.01 This section provides connection information for the 565HK and 565HKM telephone sets. 1.0

More information

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS BELL SYSTEM PRACTICES Plant Series SECTION 500-150-1 00 Issue 6, April 1970 AT&TCa Standard RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS 1. GENERAL 1.01 This section contains information on the reduction

More information

INTERCONNECTING DEVICES COMMON EQUIPMENT 75A CONTROL UNIT

INTERCONNECTING DEVICES COMMON EQUIPMENT 75A CONTROL UNIT BSP 463-300-112-i01_1973-11.01.jpg Scanned by Frank Harrell (CowboyFrank) Castle Rock. Colorado Feb 23.2016 21:15:56 BELL SYSTEM PRACTCES AT&TCo Standard SECTON 463-300-112 ssue 1, November 1973 NTERCONNECTNG

More information

AUXILIARY SIGNALS IDENTIFICA lion

AUXILIARY SIGNALS IDENTIFICA lion BELL SYSTEM PRACTCES AT& TCo Standard SECTON 463-110-100 ssue 10, Odober 1974 AUXLARY SGNALS DENTFCA lion 1. GENERAL 1.01 This section provides identification, installation, operation, maintenance, and

More information

c. Battery Charger c Volt Supply TL MICROWAVE RADIO DESCRIPTION POWER SUPPLY H. Battery Voltage Alarm Circuit.

c. Battery Charger c Volt Supply TL MICROWAVE RADIO DESCRIPTION POWER SUPPLY H. Battery Voltage Alarm Circuit. BELL SYSTEM PRACTCES Plant Series 2. OPERATNG PRNCPLES CONTENTS PAGE B. Klystron Supply Regulator and nverter. D. Battery Voltage Alarm Circuit. 3. CRCUT DESCRPTON. A. Klystron Supply Regulator and nverter.

More information

4A SPEAKERPHONE SYSTEM

4A SPEAKERPHONE SYSTEM BELL SYSTEM PRACTCES AT&TCo Standard SECTON 512-7-lOD ssue 2 September 1974 4A SPEAKERPHONE SYSTEM \ 1. DENTFCA TiON 1.1 The 4A speakerphone system is a hands-free voice switched system for use as a telephone

More information

DATA SET 109B TYPE DESCRIPTION

DATA SET 109B TYPE DESCRIPTION BELL SYSTEM Plant Series PRACTCES SECTON 312-802-100 ssue 1, December 1967 AT&TCo Swdard DATA SET 109B TYPE DESCRPTON 1. GENERAL 1.01 This section describes Data Set 109B type (109B1 and 109B2) physically

More information

INCOMING SELECTOR CIRCUITS FROM PANEL LOCAL, OFFICE TANDEM AND PANEL SENDER TANDEM OFFICES MANUAL TEST USING TEST SET ES OR ES

INCOMING SELECTOR CIRCUITS FROM PANEL LOCAL, OFFICE TANDEM AND PANEL SENDER TANDEM OFFICES MANUAL TEST USING TEST SET ES OR ES BELL SYSTEM PRACTICES Plant Series INCOMING SELECTOR CIRCUITS FROM PANEL LOCAL, OFFICE TANDEM AND PANEL SENDER TANDEM OFFICES MANUAL TEST USING TEST SET ES-20150-01 OR ES-239844,,, I' I Issue 3, November,

More information

INPUT AND OUTPUT POWER ADJUSTMENTS PRIMARY FREQUENCY CONVERTER LMX-1 AND 13 CARRIER ANALOG MULTIPLEX TERMINAL EQUIPMENT

INPUT AND OUTPUT POWER ADJUSTMENTS PRIMARY FREQUENCY CONVERTER LMX-1 AND 13 CARRIER ANALOG MULTIPLEX TERMINAL EQUIPMENT BEU SYSTEM PRACTCES SECTON 356-165-501 A7&TCa Standard ssue 4, May 1980 NPUT AND OUTPUT POWER ADJUSTMENTS PRMARY FREQUENCY CONVERTER LMX-1 AND 13 CARRER ANALOG MULTPLEX TERMNAL EQUPMENT This section explains

More information

AUXILIARY SIGNALS IDENTIFICATION, INSTALLATION, OPERATION, MAINTENANCE, AND CONNECTIONS

AUXILIARY SIGNALS IDENTIFICATION, INSTALLATION, OPERATION, MAINTENANCE, AND CONNECTIONS BELL SYSTEM PRACTCES AT& TCo Standard SECTON 463-11 0-1 00 ssue 12, October 1979 AUXLARY SGNALS DENTFCATON, NSTALLATON, OPERATON, MANTENANCE, AND CONNECTONS 1. GENERAL 1.01 This section provides information

More information

MATRIX BLOCK-1 A 1 IDENTIFICATION, INSTALLATION, WIRING, AND MAINTENANCE I

MATRIX BLOCK-1 A 1 IDENTIFICATION, INSTALLATION, WIRING, AND MAINTENANCE I ELL SYSTEM PRACTCES AT&TCo Stondord ssue 2, December 1971 MATRX LOCK-1 A 1 DENTFCATON, NSTALLATON, WRNG, AND MANTENANCE 1. GENERAL 1.01 This section provides identification, installation, wiring and maintenance

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS MODEL 6115 POTATO PEELER ML-137600 ML-137601 PRIOR MLS COVERED IN THIS CATALOG ML-19869 ML-19683 A product of HOBART 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43064 Rev.

More information

REFERENCE 1 A 1 KEY TELEPHONE SYSTEM. "TOUCH-TONE n ADAPTERS

REFERENCE 1 A 1 KEY TELEPHONE SYSTEM. TOUCH-TONE n ADAPTERS BELL SYSTEM PRACTICES AT&TCo Standard Issue 2, September 1971 REFERENCE 1 A 1 KEY TELEPHONE SYSTEM "TOUCH-TONE n ADAPTERS 1. GENERAL 1.01 This section is reissued to change relay designation H3 to L3 for

More information

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS BELLSYSTEM PRACTICES SECTION500-150-11X) AT&TCo Standard Issue 7, January 1974 RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS 1. GENERAL Transistors in amplifiers of some networks and handsets 1.01 This section

More information

DATA SETS 1 08D- AND 1 08E-TYPES SINGLE PRIVATE LINE STATION ARRANGEMENT USING DATA AUXILIARY SET 820D TEST PROCEDURES

DATA SETS 1 08D- AND 1 08E-TYPES SINGLE PRIVATE LINE STATION ARRANGEMENT USING DATA AUXILIARY SET 820D TEST PROCEDURES BELL SYSTEM PRACTCES AT&TCo Stondard. GENERAL 2. TEST EQUPMENT CARRER MONTORNG TEST A. Far-End Carrier B. Near-End Carrier CARRER SHFT TEST LOOP-BACK TEST DATA SETS 1 08D- AND 1 08E-TYPES SNGLE PRVATE

More information

1\. power 3A speakerphone systems.

1\. power 3A speakerphone systems. BELL SYSTEM PRACTICES AT&TCo Standard SECTION 501-136-100 Issue 5, May 1972 STATION TRANSFORMERS IDENTIFICATION 1. GENERAL 1.01 This section is reissued to: Include KS-20426L3 transformer Change Read,

More information

LBI-4938C. Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3. Printed in U.S.A. Maintenance Manual

LBI-4938C. Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3. Printed in U.S.A. Maintenance Manual C Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3 Printed in U.S.A. Maintenance Manual TABLE OF CONTENTS DESCRIPTION.................................................... 1 CIRCUIT ANALYSIS.................................................

More information

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS IDENTIFICATION, INSTALLATION, AND MAINTENANCE

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS IDENTIFICATION, INSTALLATION, AND MAINTENANCE AT & T PRACTICE Standard AT & T 500-150-100 Issue 11, July 1984 RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS IDENTIFICATION, INSTALLATION, AND MAINTENANCE 1. GENERAL 1.01 This practice contains information

More information

LBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A.

LBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A. D Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1 Maintenance Manual Printed in U.S.A. This page intentionally left blank 13 PARTS LIST 12 PARTS LIST LBI-31807 11 PARTS LIST 10 SCHEMATIC

More information

TELEPHONE SETS 910A AND 2910A IDENTIFICATION, INSTALLATION, AND CONNECTIONS

TELEPHONE SETS 910A AND 2910A IDENTIFICATION, INSTALLATION, AND CONNECTIONS BELL SYSTEM PRACTCES AT&TCo Standard SECTON 503-200-101 luue 1, April 1974 TELEPHONE SETS 910A AND 2910A DENTFCATON, NSTALLATON, AND CONNECTONS 1. ENERAL 1.01 This section provides identification, installation,

More information

METALLIC FACILITY TERMINAL LOOP-START AND GROUND-START TO DX OR E&M SIGNALING CONVERTERS (J99343FA, FB, FC, AND FD)

METALLIC FACILITY TERMINAL LOOP-START AND GROUND-START TO DX OR E&M SIGNALING CONVERTERS (J99343FA, FB, FC, AND FD) BELL SYSTEM PRACTCES AT&TCo Standard ssue 1, November 1979 METALLC FACLTY TERMNAL LOOPSTART AND GROUNDSTART TO DX OR E&M SGNALNG CONVERTERS (J99343FA, FB, FC, AND FD) NSTALLATON AND TESTNG,. CONTENTS PAGE

More information

* * * * * * * * * INSTALLATION AND MAINTENANCE

* * * * * * * * * INSTALLATION AND MAINTENANCE .-- )., TYPE CCRP RECTFERS * * * * * * * * * NSTALLATON AND MANTENANCE SERVCE MANUAL 595 CONTENTS Page... V. v. V. TABLE... V. NTRODUCTON..... DESCRPTON. OPERATON... A. NPUT VOLTAGE... B. CHARGNG BATTERES..

More information

AUXILIARY KHZ PILOT SUPPLY TESTS

AUXILIARY KHZ PILOT SUPPLY TESTS BELL SYSTEM PRACTCES SECTON 356-011-505 AT&TCo Standard ssue 1, June 1971 L MULTPLEX COMMON TERMNALS EQUPMENT AUXLARY 31592-KHZ PLOT SUPPLY TESTS An auxiliary 31592-kHz pilot supply (Fig 1) provides pilot

More information

TEN-TEc INSTRUCTION SHEET MODEL KRS-A

TEN-TEc INSTRUCTION SHEET MODEL KRS-A 3-75 TEN-TEc NSTRUCTON SHEET MODEL KRS-A, GENERAL The KRS-A is a solid state, integrated circuit electronic keyer incorporating a reed relay as the actual keying component. t can be used to key all gridblocked

More information

TELEPHONE SETS 701, 702, AND 711 TYPES INSTALLATION

TELEPHONE SETS 701, 702, AND 711 TYPES INSTALLATION BELLSYSTEM PRACTICES SECTION 502-710-200 Plant Series Issue 3, January, 1963 AT&TCo Standard TELEPHONE SETS 701, 702, AND 711 TYPES INSTALLATION 1.00 INTRODUCTION 2.00 GENERAL 1.01 This section covers

More information

4A SPEAKERPHONE SYSTEM

4A SPEAKERPHONE SYSTEM BELL SYSTEM PRACTCES AT & TCo Standard SECTON 512-700-100 ssue 4, May 1978 4A SPEAKERPHONE SYSTEM 1. GENERAL 1.01 This section contains identification, installation, operation, and maintenance information

More information

MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE

MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE Linear Tube Audio Takoma Park, MD, USA WARNING: For safety, the cover of this amplifier should be secured at all times. DC voltages as high

More information

COMMON AUDIBLE SIGNALING KEY TELEPHONE SYSTEMS

COMMON AUDIBLE SIGNALING KEY TELEPHONE SYSTEMS AT & TCo Standard SECTON 518-010-108 ssue 5, November 1980 COMMON AUDBLE SGNALNG KEY TELEPHONE SYSTEMS 1. GENEAL 1.01 This section provides a general description of common audible signaling arrangements,

More information

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS

RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS BELL SYSTEM PRACTICES Plant Series SECTION 500-150-1 00 Issue 6, April 1970 AT&TCo Standard RADIO SIGNAL SUPPRESSION FOR TELEPHONE SETS 1. GENERAL 1.01 This section contains information on the reduction

More information

Western Electric 106 -A AMPLIFIER INSTRUCTION BULLETIN NO. 880, ISSUE NO. 2

Western Electric 106 -A AMPLIFIER INSTRUCTION BULLETIN NO. 880, ISSUE NO. 2 Western Electric 106 -A AMPLIFIER INSTRUCTION BULLETIN NO. 880, ISSUE NO. 2 Western Electric 106 -A AMPLIFIER Type Two -stage line or main Amplifier with bridging or matching input. A complete self -contained

More information

f i r e - p a r t s. c o m

f i r e - p a r t s. c o m Model: CON 1001-1 INSTALLATION AND OPERATING INSTRUCTIONS SINGLE-FUNCTION WIRELESS REMOTE CONTROL SYSTEM FOR OPERATING VALVES WITH ON/OFF LATCHING SOLENOIDS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION

More information

CODED CARRIER CONTROL SYSTEM

CODED CARRIER CONTROL SYSTEM T DESCRPTON OF i CODED CARRER CONTROL SYSTEM. FOR USE WTH TME CODE CONTROL SYSTEMS MANUAL No. 507... Revised and Reprinted MARCH, 1947 UNON SWTCH & SGNAL CO. SWSSVALE PENNSYLVANA 2.5M-3-47-2 T COPYRGHT,

More information

TWO-POINT PRIVATE LINE TELEPHONE CIRCUITS TEST PROCEDURES

TWO-POINT PRIVATE LINE TELEPHONE CIRCUITS TEST PROCEDURES BELL SYSTEM PRACTCES SECTON 310-300-500 AT&TCo Standard ssue 7, June 1975 TWO-PONT PRVATE LNE TELEPHONE CRCUTS VOCE ONLY TEST S 1. CONTENTS GENERAL...........1 PAGE always be referred to for TLP levels,

More information

* For best quality print using Fit To Page setting in printer dialog box. SERVICE MANUAL CHGCT36

* For best quality print using Fit To Page setting in printer dialog box. SERVICE MANUAL CHGCT36 * For best quality print using Fit To Page setting in printer dialog box. SERVICE MANUAL CHGCT36 V7 Charge Cart Service Manual V7 Charge Cart Electrical Parts Replacement 1 PDU Replacement 1 Timer PDU

More information

r--- INSIDE WIRE CABLE

r--- INSIDE WIRE CABLE Scanned b Frank Harrell, (Cowbo Frank) Castle Rock, Colorado Oct 09, 01 14:6 :"ol. BELL SYSTEM PRACTICES Plant Series SECTION 461-60-1 00 Issue 1, January 1968 AT&TCo Standard CONNECTING BLOCKS 4A, 44A,

More information

REFERENCE INDUCTIVE NOISE

REFERENCE INDUCTIVE NOISE BELL SYSTEM PRACTCES AT&TCo StCindard SECTON 500-12-100 luue 8, January 1973 REFERENCE NDUCTVE NOSE ENERAL 101 This section contains information to control and minimize the effects of inductive noise at

More information

CATEGORY 5E MULTIPAIR WIRE

CATEGORY 5E MULTIPAIR WIRE CATEGORY 5E MULTIPAIR WIRE ESSEX 462219 51 240 31 ESSEX CG 5EX CMX 4P 24 GY P ESS 1K ESSEX CAT 5E CMX UV RATED 4PR 24 AWG GRY PULL BOX 1000' ESSEX 620349 ESSEX CG 5EX NP 25P 24 GY R S ESS X ESSEX CAT 5E

More information

SERVICE 2564HL, 2564HLM, AND 2564HLMS TELEPHONE SETS MAINTENANCE AND CONNECTIONS

SERVICE 2564HL, 2564HLM, AND 2564HLMS TELEPHONE SETS MAINTENANCE AND CONNECTIONS BELL SYSTEM PRACTCES AT&TCQ Standard SECTON 52-543-42 ssue 6, Noember 98 SERVCE 2564HL, 2564HLM, AND 2564HLMS TELEPHONE SETS MANTENANCE AND CONNECTONS. GENERAL.O This section contains information for the

More information

Eo Classical - Specification and Features

Eo Classical - Specification and Features Eo Classical - Specification and Features Folded dimensions 420mm long x 100mm high x 130mm wide. Weight 1.5 kg. Unfolded, overall 820 mm x 360 mm with contour wings in place. String scale length: 650

More information

SERVICE SPECIAL SAFEGUARD MEASURES SPECIAL SERVICE PROTECTION RADIO AND TELEGRAPH LOOPS

SERVICE SPECIAL SAFEGUARD MEASURES SPECIAL SERVICE PROTECTION RADIO AND TELEGRAPH LOOPS BELL SYSTEM PRACTCES Plant Series SECN 460-11 0-400 ssue 1, December 1969 AT & TCo Standard SERVCE SPECAL SAFEGUARD MEASURES SPECAL SERVCE PROTECN RADO AND TELEGRAPH LOOPS 1. GENERA L 1.01 This section

More information

DRAWINGS ON 35MM MICROFILM FOR INSTALLATION AND TELEPHONE COMPANY. EQUIPMENT MAINTENANCE lw. & [ : qp i

DRAWINGS ON 35MM MICROFILM FOR INSTALLATION AND TELEPHONE COMPANY. EQUIPMENT MAINTENANCE lw. & [ : qp i BE1l SYSTEM PRACTCES AT&TCo Standard SECTON 006-101-100 ssue 2, June 1978 DRAWNGS ON 35MM MCROFLM FOR NSTALLATON AND TELEPHONE COMPANY ----- -.._ -. _ tr, L / ~ / ;,/\ ~: ;< EQUPMENT MANTENANCE lw. & [

More information

PR-216. High Performance Personal Receiver PR-216 OPERATOR S MANUAL

PR-216. High Performance Personal Receiver PR-216 OPERATOR S MANUAL PR-216 OPERATOR S MANUAL PR-216 High Performance Personal Receiver 357 West 2700 South Salt Lake City, Utah 84115 Phone: (800) 496-3463 Fax: (801) 484-6906 http://www.comtek.com TABLE OF CONTENTS Introduction...

More information

SERVICE 2565HK AND 2565HKM TELEPHONE SETS

SERVICE 2565HK AND 2565HKM TELEPHONE SETS BEU SYSTEM PRACTCES AT & TCo Standard SECTON -54-405 ssue 7, November 1977 SERVCE 565HK AND 565HKM TELEPHONE SETS 1 GENERAL 101 This section provides connection information sets (Fig 1) for the 565HK (MD)

More information

FOXCART 400 MARK II OPERATION AND SERVICE MANUAL FOXTRONICS LOVE FIELD - DALLAS TEXAS MODEL PR APPROX. 550POUNDS THE POWER CART WITH MUSCLE

FOXCART 400 MARK II OPERATION AND SERVICE MANUAL FOXTRONICS LOVE FIELD - DALLAS TEXAS MODEL PR APPROX. 550POUNDS THE POWER CART WITH MUSCLE FOXCART 400 MARK II OPERATION AND SERVICE MANUAL MODEL PR2400-400 APPROX. 550POUNDS THE POWER CART WITH MUSCLE FOXTRONICS LOVE FIELD - DALLAS TEXAS MADE IN THE USA 3448 WEST MOCKINGBIRD LANE DALLAS, TEXAS

More information

AMPLIFIER PLUG-IN UNIT FOR TYPE "EL" CODED CAB SIGNAL EQUIPMENT

AMPLIFIER PLUG-IN UNIT FOR TYPE EL CODED CAB SIGNAL EQUIPMENT SERVCE MANUAL 5682-G Description, Operation and Maintenance AMPLFER PLUG-N UNT FOR TYPE "EL" CODED CAB SGNAL EQUPMENT Part Number N339646-001 June, 1977 (Revised July, 1984) 100073C-DN0383 B-7/84-50-1211-1

More information

FLEX2 VERSION ALLFLEX 2 LEG / 3 SECTION HEIGHT ADJUSTABLE DESK **PATENT PENDING**

FLEX2 VERSION ALLFLEX 2 LEG / 3 SECTION HEIGHT ADJUSTABLE DESK **PATENT PENDING** FLEX2 ALLFLEX 2 LEG / 3 SECTON HEGHT ADJUSTABLE DESK VERSON A NSTRUCTON MANUAL CONTENTS: FLEX-MU-2L3S-C3672-K4# FEET-ADJ-UNV-2430# V1 **PATENT PENDNG** MAX Load 265 lbs (120 KG) Equally Divided MAX Load

More information

75A-4 MODIFICATION FOR BUSHIPS. The purpose of this supplement is to show the changes in the 75A-4

75A-4 MODIFICATION FOR BUSHIPS. The purpose of this supplement is to show the changes in the 75A-4 75A-4 MODFCATON FOR BUSHPS GENERAL The purpose of this supplement is to show the changes in the 75A-4 nstruction Book (Collins part number 520 5052 00) necessary to make it agree with the-changes made

More information

23A TRANSMISSION MEASURING SET (J94023A) (DESCRIPTION)

23A TRANSMISSION MEASURING SET (J94023A) (DESCRIPTION) BELL SYSTEM PRACTICES Central Office.Mainte>ance Description of Testing Equipment and Tools Toll Test Room Operation Description and Operating Principles of Systems and Equipment SECTION A702.625 Issue

More information

803, 806, 807 instruction book 800., 801, 802, Hobbymatic

803, 806, 807 instruction book 800., 801, 802, Hobbymatic A 803, 806, 807 instruction book 800., 801, 802, Hobbymatic I 4 Fold out this page Contents Page Removing the carrying case cover 1 Foot control receptacle 1 Electrical connection 2 Foot control 2 Disengaging

More information

Lexus ES350 Window Clip Replacement

Lexus ES350 Window Clip Replacement Page 1 of 10 1.0 Purpose The following instruction details the tools and supplies required, and the steps for removing and replacing the broken window clip in your 2007-2012 Lexus ES350. 2.0 Tools and

More information

F82 INVERTER SERVICE MANUAL 6137 UNION SWITCH & SIGNAL DIVISION AMERICAN STANDARD INC./ SWISSVALE, PA PART NUMBER N CONTENTS PAGE

F82 INVERTER SERVICE MANUAL 6137 UNION SWITCH & SIGNAL DIVISION AMERICAN STANDARD INC./ SWISSVALE, PA PART NUMBER N CONTENTS PAGE F82 INVERTER PART NUMBER N-451033-4101 SERVICE MANUAL 6137 CONTENTS SECTION I II III IV v VI, PAGE GENERAL INFORMATION 1 1.1 INTRODUCTION 1 1. 2 DESCRIPTION 1 1.3 SPECIFICATIONS 1 FUNCTIONAL DESCRIPTION

More information

PRACTICAL TRANSISTOR CIRCUITS

PRACTICAL TRANSISTOR CIRCUITS PRICE 15 CENTS PRACTICAL TRANSISTOR CIRCUITS * I. 12-Watt Power Amplifier 2. Light Flasher 3. Regulated Power Supply 6. Sinusoidal Power Oscillator 7. Electroni~ Photoflash Power Supply 4. Regulated Power

More information

TCI Library-

TCI Library- Section L of TELEPHONE EQUIPMENT & SUPPLIES CATALOG ISSUED SEPTEMBER, 1966 RECORDERS & ANNOUNCERS Recorder,-Announcers Type INT, Single-Channel, Fixed Message Length, Compact Transistorized Recorder-Announcers;

More information

LBI-31564A. Mobile Communications. DELTA - SX MHz RADIO COMBINATIONS (NEGATIVE GROUND ONLY) Maintenance Manual

LBI-31564A. Mobile Communications. DELTA - SX MHz RADIO COMBINATIONS (NEGATIVE GROUND ONLY) Maintenance Manual A Mobile Communications DELTA - SX 136-174 MHz RADIO COMBINATIONS (NEGATIVE GROUND ONLY) Maintenance Manual TABLE OF CONTENTS MILITARY AND SYSTEM SPECIFICATIONS................................. 2-3 COMBINATION

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

VOICE CONNECTING ARRANGEMENTS QKT AND QKTBT 30-TYPE VOICE COUPLER

VOICE CONNECTING ARRANGEMENTS QKT AND QKTBT 30-TYPE VOICE COUPLER BSP 463-311-100-i05_1974.Q3.Q1.jpg Scanned by Frank Harrell (CowboyFrank) Castle ock. Colorado Feb 23,2016 21:24:32 BELL SYSTEM PACTCES AT&TCo Standard SECTON 463-311-100 ssue 5, March 1974 VOCE CONNECTNG

More information

Includes Instructions on Installation, Programming, and Troubleshooting for use with G-TEL Payphones with Model Series-5 Elcotel Smart Chassis

Includes Instructions on Installation, Programming, and Troubleshooting for use with G-TEL Payphones with Model Series-5 Elcotel Smart Chassis Includes Instructions on Installation, Programming, and Troubleshooting for use with G-TEL Payphones with Model Series-5 Elcotel Smart Chassis Version 2.0 TABLE OF CONTENTS INTRODUCTION... 2 IMPORTANT

More information

Walkie-Talkie. User Manual and Instruction. Getting Started

Walkie-Talkie. User Manual and Instruction. Getting Started Walkie-Talkie User Manual and Instruction Getting Started Installing the AA Batteries Your radio uses 3 AA Alkaline batteries. 1. With the back of the radio facing you, lift the battery latch up to release

More information

Radio Control Installation and Operating Instructions System 4

Radio Control Installation and Operating Instructions System 4 Radio Control Installation and Operating Instructions System 4 P.O. Box 403, One Cedar Parkway, Jackson, WI 53037 Phone: 800-628-1909 Fax: 262-677-2058 Revision: April 19, 2012 Contents Introduction 3

More information

Treasure Hunter Bronze Metal Detector PHMD1

Treasure Hunter Bronze Metal Detector PHMD1 Treasure Hunter Bronze Metal Detector PHMD1 www.pyleaudio.com Instruction Manual This Metal Detector is a versatile and easy-to-use metal detector. It has higher sensitivity and has the ability to differentiate

More information

~'----MA_N_UAL_5_ J~

~'----MA_N_UAL_5_ J~ WABCC '----MA_N_UAL_5_43 -...J STYLE FST FREQUENCY SHFT CARRER EQUPMENT CONTENTS Section No. Title Page V NTRODUCTON. 1. 1 Purpose DESCRPTON AND OPERATON. 2. 1 General.... 2. 2 Application.... 2. 3 Circuit

More information

Juno 40 Inch Round Chandelier Assembly and Installation Instructions

Juno 40 Inch Round Chandelier Assembly and Installation Instructions CAUTON: uno 40 nch Round Chandelier Assembly and nstallation nstructions BEFORE NSTALLN FXTURE, MAKE SURE TE POWER TO TE CRCUT S TURNED OFF AT TE MAN FUSE BOX / CRCUT BREAKER UTLTY BOX. mportant Safety

More information

Sliding Crosscut Table installation guide

Sliding Crosscut Table installation guide Sliding Crosscut Table installation guide model tsa-sa48 A Note About Color Variations Among Anodized Aluminum Components Congratulations on the purchase of this SawStop Sliding Crosscut Table. We at SawStop

More information

model tsa-sa48 Sliding Crosscut Table installation guide

model tsa-sa48 Sliding Crosscut Table installation guide model tsa-sa48 Sliding Crosscut Table installation guide A Note About Color Variations Among Anodized Aluminum Components Congratulations on the purchase of this SawStop Sliding Crosscut Table. We at SawStop

More information

Operating Instructions

Operating Instructions Operating Instructions Torque Transducer Type CD9515 Series Please read instruction carefully. Important Advice: The torque transducers of type CD9515 are suitable for applications in laboratories (for

More information

ABM International, Inc. Navigator Assembly Manual

ABM International, Inc. Navigator Assembly Manual ABM International, Inc. 1 1.0: Parts List Tablet (Qty. 1) Tablet mount (Qty. 1) NOTE: Mount may appear and operate different then image below Control Box (Qty. 1) Motor Power Supply (Qty. 1) 2 X-axis motor

More information

On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual

On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual Full installation instructions accompany your Cardio Theater equipment order. This On-Line version of our Installation/Instruction

More information

LANDICE - E-SERIES ELLIPTIMILL PART # WITH EXPLODED VIEW #

LANDICE - E-SERIES ELLIPTIMILL PART # WITH EXPLODED VIEW # FRAME & SHROUD COMPONENTS E7/E950 Frame, E7/E950 91059 S1 NOT AVAIL FOR PURCHASE E7/E950 Crank house bearing (Crank/Spindle) 91213 81 4 per Frame E7/E950 Screw Clip (M5) 91070 70 E7/E950 M5 x 10 Phillips

More information

1825 Duet Plus Installation Guide

1825 Duet Plus Installation Guide 1825 Duet Plus Installation Guide Algo Communication Products Ltd. www.algosolutions.com 90-00046B - 1 - Table of Contents Release 2 Updates - Feb. 2012... 3 Quick Install for Dry Contact Ringing... 4

More information

UNITED MOTORS SERVICE D IV ISIO N OF GENERAL M O TO RS C O R P O R A T IO N. General Offices - Detroit AUTO RADIO BULLETIN

UNITED MOTORS SERVICE D IV ISIO N OF GENERAL M O TO RS C O R P O R A T IO N. General Offices - Detroit AUTO RADIO BULLETIN UNITED MOTORS SERVICE D IV ISIO N OF GENERAL M O TO RS C O R P O R A T IO N General Offices - Detroit AUTO RADIO BULLETIN Bulletin 6D-855 Date 11-1-54 Page 1 FIRST ISSUE SUBJECT: SERVICE INSTRUCTIONS -

More information

Repair Parts List REFRIGERATOR MODEL NUMBER MANUFACTURING NUMBER P W

Repair Parts List REFRIGERATOR MODEL NUMBER MANUFACTURING NUMBER P W REFRIGERATOR Repair Parts List MODEL NUMBER 85288 MANUFACTURING NUMBER P1109012W When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model

More information

Agilent N3300 Series DC Electronic Loads

Agilent N3300 Series DC Electronic Loads Agilent N3300 Series DC Electronic Loads Data Sheet Increase your manufacturing test throughput with fast electronic loads Increase test system throughput Lower cost of ownership Decrease system development

More information

ELSEMA. GLR2701 Single Channel 27MHz Gigalink Receiver with Timer Controlled Relay Output

ELSEMA. GLR2701 Single Channel 27MHz Gigalink Receiver with Timer Controlled Relay Output GLR2701 Single Channel 27MHz Gigalink Receiver with Timer Controlled Relay Output ELSEMA Features Wide supply connection 11.0 to 28.0 Volts AC/DC Highly sensitive receiver input stage. When used with GLT27.

More information

SEWING MACHINE CABINET OWNER'S MANUAL. Model Number Oak _90 White Cherry ASSEMBLY PARTS LIST

SEWING MACHINE CABINET OWNER'S MANUAL. Model Number Oak _90 White Cherry ASSEMBLY PARTS LIST SEWNG MACHNE CABNET OWNER'S MANUAL Model Number 272.98300.490 Oak 272.98301.4_90 White 272.98302.490 Cherry ASSEMBLY PARTS LST MPORTANT: Read instructions before assembling. 98300-FC 98301-FC 98302-FC

More information

Standard PS-P61 Punch Stapler

Standard PS-P61 Punch Stapler Standard PS-P61 Punch Stapler Instruction Manual Provided By http://www.mybinding.com http://www.mybindingblog.com PUNCH STAPLE PS-P61 Important Information - This manual is designed to help you to install,

More information

Dear Valued Customer,

Dear Valued Customer, Dear Valued Customer, Thank you for choosing Listen! All of us at Listen are dedicated to provide you with the highest quality products available. We take great pride in their outstanding performance because

More information

Design Of Low-Power Wireless Communication System Based On MSP430 Introduction:

Design Of Low-Power Wireless Communication System Based On MSP430 Introduction: Design Of Low-Power Wireless Communication System Based On MSP430 Introduction: Low power wireless networks provide a new monitoring and control capability for civil and military applications in transportation,

More information

MGE TM Galaxy TM , 60 Hz kva

MGE TM Galaxy TM , 60 Hz kva Home Alarms Online Trend Statistics Rectifier Battery Inverter Bypass AC Bypass Output Set up Normal AC Q4S Load protected QBP QF 0 Hour 50 Min. 5 kva 00% 0% 00% 0 50% Load equipment 0 80% 50% Remote vision

More information

Instructions MODIFICATION KIT MODEL SBM - 1O2-1 INTRODUCTION PARTS LIST FOR THE

Instructions MODIFICATION KIT MODEL SBM - 1O2-1 INTRODUCTION PARTS LIST FOR THE Instructions FOR THE MODIFICATION KIT MODEL SBM - 1O2-1 INTRODUCTION This modification Kit applies to the following Heath Transceivers: 1. All Models HW-100, SB-100, SB-101 and SB-101W. 2. Any Model SB-102

More information

Senior Swing. Caution

Senior Swing. Caution *740132* 740132 2800 Overhead Concealed Series 9500 Surface Applied Series Senior Swing Installation Instructions Caution LCN Senior Swing The Senior Swing Power Operator System is a low energy product

More information

HP Archive. This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web!

HP Archive. This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web! HP Archive This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web! Thanks to on-line curator: Ken Manders OPERATING AND SERVICE MANUAL K05-5060A..~,

More information

May 3, 1984

May 3, 1984 WILLIAMS 16-543-103 May 3, 1984 S T I L L C R A Z Y R SERVICE MANUAL For service... Call your authorized WILLIAMS distributor WILLIAMS Electronics, Inc. 3401 N. California Ave. Chicago, IL 60618 ROM Summary

More information

INSTRUCTION PAMPHLET U-5743

INSTRUCTION PAMPHLET U-5743 WABCC I! I,. INSTRUCTION PAMPHLET U-5743 INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR UNION TRANSISTORIZED UNIT CARRIER INTRODUCTION The Union Transistorized Unit Carrier equipment is a keyed frequency

More information

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from LAPP products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph:(10)358-3130 (800)638-1830 fx:(10)358-312 (800)872-9329 RFQ form: http://mdmetric.com/rfq.htm Flexible Tray

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TreadClimber INSTALLATION INSTRUCTIONS STAR TRAC FITNESS 1 of 14 635-4175 Rev: B NOTICE Installation of this product requires that 2 or more people are available to safely perform certain steps outlined

More information

KWM1900 Wireless microphone system

KWM1900 Wireless microphone system KWM1900 Wireless microphone system M A N U A L V E R S I O N 2. 0 2 2-1 1-1 1 Uses future proof frequencies UHF 863.00-865.00MHz frequency band SMT technology Preset 16 channel PLL system Frequency stabilisation:

More information

The World s Most Advanced Wireless Door Control System

The World s Most Advanced Wireless Door Control System The World s Most Advanced Wireless Door Control System Only LAZERPOINT RF provides the largest selection of activation devices, the most reliable performance and the lowest installation cost! www.camdencontrols.com/lazerpoint

More information

V-119RT 19 STATION ROTARY-TONE INTERCOM

V-119RT 19 STATION ROTARY-TONE INTERCOM VSP-V-119RT Issue 6 V-119RT 19 STATION ROTARY-TONE INTERCOM GENERAL These instructions provide identification, installation, operation, connection and maintenance information for the V-119RT intercom unit.

More information

igeacom User Guide V2.0

igeacom User Guide V2.0 Quality Care through innovative technology igeacom User Guide V2.0 IgeaCare Systems Inc. 5650 Tomken Road, Unit #9, Mississauga, Ontario, L4W 4P1, Canada Tel: 905.361.6225 Fax: 905.361.6209 www.igeacare.com

More information

Hot Water for the K2. K1RFD Building the K2 More K2 Photos. Using an HW-101 as a 100-watt PA. Hot Water for the K2. EchoStation

Hot Water for the K2. K1RFD Building the K2 More K2 Photos. Using an HW-101 as a 100-watt PA. Hot Water for the K2. EchoStation Page 1 of 5 K1RFD Building the K2 More K2 Photos EchoStation Using an HW-101 as a 100-watt PA When I was a young ham in 1977, I saved money to buy and build a Heathkit HW-101. The rig has served me well

More information

INSTALLATION AND CUSTOMER CARE INFORMATION FOR SC FREESTANDING STERILIZATION CENTERS

INSTALLATION AND CUSTOMER CARE INFORMATION FOR SC FREESTANDING STERILIZATION CENTERS INSTALLATION AND CUSTOMER CARE INFORMATION FOR SC144-200 FREESTANDING STERILIZATION CENTERS General Information: Many Artizan Design Free-standing Sterilization Centers are custom designed and built to

More information

4A SPEAKERPHONE COMPONENTS. IDENTIFICA lion, INST ALLA lion, OPERA lion, AND MAINTENANCE

4A SPEAKERPHONE COMPONENTS. IDENTIFICA lion, INST ALLA lion, OPERA lion, AND MAINTENANCE BELL SYSTEM PRACTICES AT& TCo Standard SECTION 512-700-100 Issue 5, April 1979 4A SPEAKERPHONE COMPONENTS IDENTIFICA lion, INST ALLA lion, OPERA lion, AND MAINTENANCE 1. GENERAL 1.01 This section contains

More information

INSTRUCTION BOOK FOR ST ANDA RD RA TIO TRANSFORMER '1RATIOTRAN"

INSTRUCTION BOOK FOR ST ANDA RD RA TIO TRANSFORMER '1RATIOTRAN NSTRUCTON BOOK FOR ST ANDA RD RA TO TRANSFORMER '1RATOTRAN" GERTSCH PROD UC TS, NC. 3211 La Cienega Boulevard Los Angeles 16, California TABLE OF CONTENTS SECTON SECTON SECTON SECTON V SECTON V GENERAL

More information

EXES-6000 TOA INTERCOM SYSTEM. System Specifications Exchange EX-610/620 (CP-66 Version)

EXES-6000 TOA INTERCOM SYSTEM. System Specifications Exchange EX-610/620 (CP-66 Version) EXES-6000 TOA INTERCOM SYSTEM System Specifications Exchange EX-610/620 (CP-66 Version) EXES-6000 General Description TOA Intercom system EXES-6000 is composed of central exchange EX-610/620 and stations

More information

2007 Honda CR-V EX. KTC trim tool set SOJATP2014 * Trim pad remover, Snap-on A177A or equivalent, commercially available

2007 Honda CR-V EX. KTC trim tool set SOJATP2014 * Trim pad remover, Snap-on A177A or equivalent, commercially available Special Tools Required KTC trim tool set SOJATP2014 * Trim pad remover, Snap-on A177A or equivalent, commercially available * Available through the American Honda Tool and Equipment Program; call 888-424-6857

More information

Experiment #5 Series and Parallel Resistor Circuits

Experiment #5 Series and Parallel Resistor Circuits Experiment #5 Series and Parallel Resistor Circuits Objective: You will become familiar with the MB Board and learn how to build simple DC circuits. This will introduce you to series and parallel circuits

More information