1 Digital Handheld Magnetic Transmitter Transmitter Field Transmitter GSP303D 3-Axis Digital Magnetic Field Transmitter Digital Output (RS485) Accuracy Based on Reading (Not Range) Wide Supply Power: 5 to 36VDC Description: With industry standard design, 3-Axis Digital Magnetic Field Transmitter GSP303D, could measure magnetic fields and output digital signals (Bx, By, Bz) of a magnetic flux density via RS485, which is easy to make into an integrated system, and able to meet the industrial production of a variety of complex environments and requirements. Typical applications are: Magnetic Field Map (magnetic field mapping & scanning system), incoming test in production line, quality control and monitoring system (generator, motor), distribution test of pulsed magnetic field and gradient magnetic field, multi-point synchronous testing of space magnetic field, material surface magnetic field detection and so on. 3-Axis Digital Magnetic Field Transmitter GSP303D s accuracy is based on reading, not the measurement range. Transmitter GSP303D s measurement range can be chosen, such as 300G, 1KG, 3KG, 10KG, 30KG, 100KG, 300KG or to be customized, with the reading-based accuracy of 1% (0.5% or 0.1% also can be chosen), and frequency response from DC to 1KHz or 50KHz. Transmitter GSP303D s power supply is very unique, as 5VDC- 36VDC wide power supply. Lack of power supply or power supply equipment failure situation will lead to voltage instability, and will be likely to cause instability in the test data or hardware damage. Wide voltage power supply effectively ensures that GSP303D will work stably and has better reliability when power supply voltage is unstable. There is a unique feature for 3-axis probe of Transmitter GSP303: With the MEMS manufacturing technology, 3-axis probe sensor provides very high spatial resolution (0.1*0.1*0.1mm 3 ) and high angular accuracy (orthogonality error < 0.05 ), and the thickness of 3-axis probe is 2mm, and it s suitable for institutes, universities and enterprises. Transmitter GSP303D s typical probes adopt the instrument-grade GaAs Hall Sensor which >>1
2 Digital Magnetic Field Transmitter owns a temperature coefficient of 500ppm/. However, Temperature sensor-contained probes (probes with built-in temperature sensor) have the function of temperature compensation, so temperature sensor-contained probes are strongly recommended for better precision and stability when the temperature changes and it s suitable for institutes, universities and enterprises. Transmitter GSP303D can be equipped with different kinds of 3-Axis Probes: Standard 3-Axis Probe and Temperature sensor-contained 3-Axis Probe. Also according to the special needs of customers, it s possible to customize probe s range, shape, size and cable length. Meanwhile, Transmitter GSP303D has passed the CE certification and EMC (Electromagnetic Compatibility) test. Features Manufactured by industry standards Instrument-grade GaAs Hall Sensor Digital outputs (RS485: Bx, By, Bz), easy to integrate To form a multi-point magnetic field synchronization detection system Power supply voltage 5VDC- 36VDC Through EMC test Certificated by CE standard Equipped with Smart PC Software Accuracy of 1%, 0.5% or 0.1% Range of 300G, 1KG, 3KG, 10KG, 30KG, 100KG, 300KG or to be customized Frequency response: DC to 1KHz or 50KHz High orthogonality accuracy (< 0.05 ) High spatial resolution(0.1*0.1*0.1mm 3 ) Temperature sensor-contained Probe: Temperature compensation Probe thickness: only 2mm Probe can be customized Smart PC Software Interface 2<<
3 Handheld Transmitter Digital Magnetic Field Transmitter GSP303D Transmitter Specification: MODEL GSP303D Measurement Specification Accuracy(DC) Range Best Resolution Frequency Response ±1% of reading ± 0.1% of range ±0.5% of reading ± 0.08% of range ±0.1% of reading ± 0.05% of range 300G, 1KG, 3KG, 10KG, 30KG, 100KG, 300KG or to be customized 0.01G (1μT) DC - 1KHz or DC- 50KHz Temperature Coefficient <±500ppm/ <±100ppm/ [Typical Probe] [Temperature Sensor-contained Probe] Zero Drift Long-term Instability of Sensitivity RS485 Interface Probe <±0.05% of Full Scale within 168 hours <0.1% over 1 year Cable: MAX. 500m; Data update rate: MAX. 100 Sample/s Probes SMART PC Software Standard 3-Axis Probe and Temp. sensor-contained 3-Axis Probe Function 1, Automatically record and display trend graph; 2, Display magnetic flux density, maximum and minimum in real time; 3, Choose DC Measurement Mode or AC Measurement Mode. Transmitter Specification Operating Temperature Storage Temperature Power Consumption Power Supply Dimension Weight Certification -20 C to +75 C -20 C to +80 C (MAX)1.2W 5VDC- 36VDC 165 mm W 95 mm H 40 mm D 300g CE Certification, EMC Certification >>3
4 Digital Magnetic Field Transmitter GSP303D Transmitter s Connection and Terminals Description Digital Signal Output (RS485: Bx, By, Bz) Power Supply (5VDC- 36VDC) 1, Transmitter Terminals Description Terminals Description 485_A 485_B Digital Signal Output (RS485: Bx, By, Bz) [Cable Length: max. 500m] V+ DC Power Supply V- (5VDC- 36VDC) 2, Probe s Dimension Probe Specification Probe Type and Specification Probe Dimension Probe cable length The position of sensor center See in Description Of Transmitter Type Selection 20 x 4.5 x 2mm See in Description Of Transmitter Type Selection D=3mm ± 0.2mm 4<<
5 Handheld Transmitter Digital Magnetic Field Transmitter Description Of Transmitter Type Selection Description Option Example Output Type of Transmitter GSP303 Range Accuracy (Based on reading) Probe Cable Length Temp. compensation (Temperature sensor-contained Probe) Note: GSP303A: Analog Output (±10V) GSP303D: Digital Output (RS485) 300G 1KG 3KG 10KG 30KG 100KG 300KG OR to be customized 1% 0.5% 0.1% 2m 5m 10m 20m 30m OR to be customized No Code: None TC: Yes GSP303D 30KG 1% 2m TC 1, GSP303D-30KG-1%-2m is the standard model of 3-Axis magnetic field transmitter GSP303D; users should select output type, range, accuracy, frequency bandwidth, probe cable length and sensitivity to DC magnetic field before an order; if customers have other special requirements (such as pulse magnetic field, high-speed magnetic field measurement sampling, high temperature or low temperature measurement environment, underwater magnetic field monitoring measurements, etc.), please contact Coliy. 2, The digital output accuracy is based on reading, and not affected by Range; 3, Frequency Response: DC- 1KHz or DC- 50KHz can be chosen; 4, Temperature sensor contained Probe, has the function of temperature compensation, and the temperature coefficient is <±100ppm/ ; 5, Each 3-axis probe s fully calibrated measurement range: ±20KG (±2T); 6, Probe s default operating temperature: -20 to +75 ; 7, 3-Axis Magnetic Field Transmitter GSP303 has two models, one is GSP303A with analog output (XYZ, ±10V), and the other is GSP303D with digital outputs (RS485: Bx, By, Bz). >>5
6 Digital Magnetic Field Transmitter Optional Accessories PS2012 ZC10 Model Descriptions Power Adapter; Input: 100VDC- 230VDC; Output: ±12VDC, 5A Zero chamber, provides up to 80 db attenuation in fields up to 500 G and can be used with standard probes. Internal dimension of the Chamber: diameter 6.8mm x 44.5mm S485USB RS485 to USB adapter The most popular Package Package Product No. GSP303D01: Transmitter GSP303D-30KG-1%-2m + Zero Chamber ZC10 Precision Description Of COLIY Transmitter When using Transmitter to measure magnetic field in the environment that ambient temperature changes obviously, it s recommended to use temperature sensor- contained probe with the Transmitter. Temperature sensor-contained probe has the function of temperature compensation for better precision and stability when the temperature changes. When the magnetic field is within 30KG (3T), users could directly choose the accuracy grade according to users desired accuracy. For example, users use transmitter, whose accuracy is 1%, to detect a magnetic field at about 1000G. Then transmitter s reading range is 1000G ± 1000G * 1%, instead of 1000G ± 30000G * 1%, for COLIY transmitter s accuracy is based on reading rather than transmitter s range. (30000G is the transmitter s range, 30000G= 3T) Due to continuous process improvement, specifications subject to change without notice. Document trademarks and product names are trademarks of Coliy Technology GmbH. Amendment 1,Publishing:NSF-English <<
Handheld Gaussmeter Gaussmeter
Handheld Gaussmeter Gaussmeter G93 Handheld Wide-range 3-Axis Gaussmeter Magnetic field measurement from 10nT(0.1mG) to 30T(300KG), and the range spans 10 9. Description: With many years of magnetic field
More informationLow Cost Three-Axis Fluxgate Sensor GFS-E. Measurement Range up to ±1000μT Output Voltage Calibration Error: 0.5% Noise 20pTrms/ Hz at 1Hz
Handheld 3-Axis Gaussmeter Gaussmeter Fluxgate Low Cost Three-Axis Fluxgate GFS-E Measurement Range up to ±1000μT Output Voltage Calibration Error: 0.5% Noise 20pTrms/ Hz at 1Hz Description: Low Cost Three-Axis
More informationF3A Magnetic Field Transducers
DESCRIPTION: The F3A denotes a range of SENIS Magnetic Fieldto-Voltage Transducers with fully integrated 3-axis Hall Probe. The Hall Probe contains a CMOS integrated circuit, which incorporates three groups
More informationH3A Magnetic Field Transducer
DESCRIPTION: The H3A denotes a range of Low Noise SENIS Magnetic Field-to-Voltage Transducers with hybrid 3- axis Hall Probe. The Hybrid Hall Probe integrates three highresolution with good angular accuracy
More informationSSI Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions
SSI Inclinometer Features - Isolated SSI synchronous serial output - Compatible RS422 - Max transfer distance 400 m - IP67 protection - EMI/ESD protection - Patent tilt measuring technical, real high accuracy
More informationPicture 1 PC & USB Connection
USB Ethernet HART Profi-bus DeviceNet EtherCAT CANopen CAN RS Zigbee Analog Switch Vibration-wire PWM SSI CDMA GPRS Wi-Fi USB Inclinometer Features - Reference with USB2.0 protocol - P2P and compatible
More informationAnalysis of static and time-variable magnetic fields
Magnetometer HP-01 Analysis of static and time-variable magnetic fields Field exposure evaluation according to current standards and regulations such as Directive 2013/35/EU for workplaces Frequency-selective
More informationF1A Magnetic Field Transducers
DESCRIPTION: The F1A denotes a range of SENIS Magnetic Fieldto- Voltage Transducers with fully integrated 1-axis Hall Probe. It measures magnetic fields perpendicular to the probe plane (By). The Hall
More informationI1A Magnetic Field Transducers
DESCRIPTION: The I1A denotes a range of SENIS Magnetic Fieldto-Voltage Transducers with integrated 1-axis Hall Probe. It measures magnetic fields perpendicular to the probe plane (By). The Hall Probe contains
More informationSDM3045X Digital Multimeter. DataSheet
SDM3045X Digital Multimeter DataSheet-2016.06 User-friendly Design Product Overview SDM3045X is a 4½ digit digital (60000 count) multimeter incorporating a dual-display and is especially well suited for
More informationMGA103 Single Axis MEMS Gyro with Triaxial Accelerometer
Cost Effective Z Axis MEMS Gyro with 3 Accelerometers Heading: diverging 0.1 /hour Range: acc ±2g, gyro ±300 /s, (ODM supported) Wide Input Power Range: 6~14VDC Compact and Lightweight - 50 x 45 x 21 (mm),
More informationGPRS Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions
GPRS Inclinometer Features - Industry GPRS interface - Quad-Band 850/ 900/ 1800/ 1900 MHz Transmission - worldwide - Support PBCCH, CSD up to 14.4 kbps - Support single/multi-center modes - Support domain
More informationI1A Magnetic Field Transducers Very Low Noise & Offset Magnetic Transducers with Integrated 1-axis (Y) Hall Probe DESCRIPTION: The I1A denotes a range
DESCRIPTION: The I1A denotes a range of SENIS Magnetic Fieldto-Voltage Transducers with integrated 1-axis Hall Probe. It measures magnetic fields perpendicular to the probe plane (By). The Hall Probe contains
More informationMG100 Single Axis MEMS Gyro
Cost Effective Z Axis MEMS Gyro Heading: diverging 0.1 /hour Range: gyro ±300 /s, (ODM supported) Wide Input Power Range: 6~14VDC Compact and Lightweight - 50 x 45 x 21 (mm), 70g Wide Working Temperature:
More informationIMU60 Inertial Measurement Unit
Precision 6 DoF MEMS Inertial Measurement Unit Range: acc ±2g, gyro ±300 /s, (ODM supported) Acc Bias Instability: ±70mg, Gyro Bias Instability: 24 /h Data Update Rate: 100Hz Wide Input Power Range: 5~18VDC
More informationthin and flexible probes factory calibration certificate with traceability High precision Analog output: DC 35 khz (depending on probe type)
Am Borsigturm 54 1357 Berlin AS-active-probes Calibrated probes for nt-, µt-, mt- and T- range thin and flexible probes factory calibration certificate with traceability High precision Analog output: DC
More informationMoving Test - MT3000
Moving Test - MT3000 Three-Phase Portable Test System Keep ahead with Modular Design The Modular Concept The MT3000 is based on a real modular design concept to provide the greatest possible flexibility
More informationSDM3045X Digital Multimeter. DataSheet
SDM3045X Digital Multimeter DataSheet-2018.12 User-friendly Design Product Overview SDM3045X is a 4½ digit digital (60000 count) multimeter incorporating a dual-display and is especially well suited for
More informationEMI Pre-Compliance Testing Solution
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com EMI Pre-Compliance Testing Solution GW Instek introduces the latest and comprehensive
More informationElectromagnetic Field Measurement System
Electromagnetic Field Measurement System Electromagnetic Field Measurement System Magnetic Near Field Probes Low-frequency (Active Probes) Low-frequency, High-current, Wideband High-frequency (GHz), Wideband
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationSC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.
SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter Datasheet Rev 1.2 2017 SignalCore, Inc. support@signalcore.com P R O D U C T S P E C I F I C A T I O N S Definition of Terms The following terms are used
More informationContinuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3
Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3 GHz Magnetic fields monitoring from 10 Hz to 5 khz Automatic
More informationNarda EMF drive test solution
Area Monitor System AMB-8059 Car Mounting Kit option Narda EMF drive test solution ITU-T K.113 Compliant Automated EMF drive test solution covered by isotropic antennas Interchangeable probes from 10 Hz
More informationSpectrum Analyzers 2680 Series Features & benefits
Data Sheet Features & benefits n Frequency range: 9 khz to 2.1 or 3.2 GHz n High Sensitivity -161 dbm/hz displayed average noise level (DANL) n Low phase noise of -98 dbc/hz @ 10 khz offset n Low level
More information3-Axis Magnetometer on a Chip. Philip Keller
3-Axis Magnetometer on a Chip Philip Keller Why magnetometers? You can only make as well as you can measure Joseph Whitworth 1803-1887 Engineer, entrepreneur, inventor, philanthropist Credit: Grace s Guide
More informationMagnetic Field Compensation System MR-3
Magnetic Field Compensation System MR-3 (DC 1kHz) (DC 10kHz) Description Magnetic Field Compensation System MR-3 can compensate the magnetic field which is measured in three axes. Therefore, it can reduce
More informationHigh Stability Voltage Source
Bilt System module - BE2100 High Stability Voltage Source Voltage to ±12V, current to ±200mA High Resolution: 21 bits, 6 ½ digits Ultra Low Noise: down to 6µVp-p Clean output noise spectrum with no spike
More informationModel D875 Mini Tuff Tilt Digital Tiltmeter
The model 875 Mini Tuff Tilt Tiltmeter combines high precision and durability in a miniaturized and economical instrument package. Using MEMS technology, the 875 delivers superior measurement accuracy
More informationEMC-scanner. HRE-series. See it before you CE it!
EMC-scanner HRE-series See it before you CE it! Print Screen image of a scan measurement. Seeing high frequencies! Now you can SEE high frequency electro magnetic fields. The background There are high
More informationFeed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies
ULTRASTAB 866 Precision Current Transducer The Ultrastab 866 Current Transducer is the most proven fluxgate transducer with onboar electronics in the Danfysik Current Transducer program. It is the first
More informationDQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 1000A Features Linearity error maximum 1 ppm Fluxgate,
More informationLUXONDES. See the electromagnetic waves. Product 2018 / 19
LUXONDES See the electromagnetic waves Product 2018 / 19 RADIO WAVES DISPLAY - 400 The Luxondes radiofrequency to optical conversion panel directly displays the ambient EM-field or the radiation of a transmitting
More informationLOW COST SDI 2210, 2260 & 2266 HIGH PERFORMANCE SDI 2220 & 2276
LOW COST & HIGH PERFORMANCE 1-AXIS DC ACCELEROMETER MODULES Low Noise: 10 μg Hz Typical for ±2g Full Scale Versions -55 to +125 C Operating Temperature Range Flexible +8 to +32 VDC Power Excellent Long
More informationAdditel 875 Series Dry Well Calibrators
Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect
More informationF3A Magnetic Field Transducers High Spatial Resolution Magnetic Transducers with Fully Integrated 1-, 2-, 3-axis Hall Probe DESCRIPTION: KEY FEATURES:
F3A Magnetic Field Transducers High Spatial Resolution Magnetic Transducers with DESCRIPTION: KEY FEATURES: The F3A denotes a range of SENIS Magnetic Fieldto-Voltage Transducers with fully integrated 3-axis
More informationConfocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position
Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position 2 optoncdt 2401 Confocal displacement measurement system - Non-contact measurement principle
More informationDSA700 Series Spectrum Analyzer
DSA700 Series Spectrum Analyzer Product Features: All-Digital IF Technology Frequency Range from 100 khz up to 1 GHz Min. -155 dbm Displayed Average Noise Level (Typ.) Min.
More informationSystem description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7
Ultra Wide Band test setup System description 1. UWB TEST SYSTEM DESCRIPTION... 2 2. SYSTEM MONITORING... 5 3. OTHER MEASUREMENT SYSTEMS & ACCESSORIES... 6 3.1 OSCILLOSCOPE & SHIELDED ENCLOSURE... 6 3.2
More informationMAGNETOSCAN MAGNETIC MEASURING SCANNER
LABORATORIO ELETTROFISICO MAGNETOSCAN MAGNETIC MEASURING SCANNER Fully automated ease with micrometrical accuracy A magnetic measuring scanner, the Magnetoscan is designed to measure the superficial magnetic
More informationChambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission
Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission Core-6 EMI Receiver 9 khz 6 GHz Features: Frequency ranges: 9 khz 30 MHz and 30 MHz 6 GHz Fully compliant acc. to CISPR 16-1-1
More informationDS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 600A Features Linearity error maximum 1.5 ppm Fluxgate,
More informationSCXI 8-Channel Isolated Analog Input Modules
SCXI 8-Channel Isolated Analog Input NI, NI SCXI-1120, NI SCXI-1120D 8 channels 333 ks/s maximum sampling rate Gain and lowpass filter settings per channel Up to 300 V rms working isolation per channel
More informationSelective and broadband low frequency field analysis
ELECTRIC AND MAGNETIC FIELD ANALYZER EHP-50C Selective and broadband low frequency field analysis Electric and magnetic low frequency field analysis up to 100 khz Isotropic measurement with a dynamic range
More informationPM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu
PM8005/6 AC and DC supply options 5 digit LED display Direct access menu Functions for calibration, alarm setting and more Wide range of optional functions Description The PM8000 Series digital panel meters
More informationPrinciples of operation 5
Principles of operation 5 The following section explains the fundamental principles upon which Solartron Metrology s linear measurement products are based. > Inductive technology (gauging and displacement)
More informationManage Electrode Reaction Resistance, Electrolyte Resistance, and Welding Resistance
BATTERY IMPEDANCE METER BT456 Manage Electrode Reaction Resistance, Electrolyte Resistance, and Welding Resistance The Ultimate Instrument for Measuring Large-Capacity Li-ion Batteries for EVs 2 Improve
More informationDL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.
DL000ID Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 6 ppm offset
More informationApplication Note PE003
Projekt Elektronik Fon +493 43 3 4 Am orsigturm 4 37 erlin Fax +493 43 3 43 Application Note PE3 Linearity curves Linearity Curve... Explanation... Typical Linearity Curves... AS-Active-Probe AS-HAP...
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationTechnical Information
Technical Information Power Sensor R&S NRP-Z91 Universal power measurement from 9 khz to 6 GHz The Power Sensor R&S NRP-Z91 is designed for measuring average power in a very wide frequency range. In particular,
More informationDS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 2000A Features 20 ppm linearity 15 ppm offset 10V
More informationDM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis
Ultra-stable, high precision (ppm class) fluxgate technology DM Series current transducer for non-intrusive, isolated DC and AC current measurement up to 1500A Features Ø45mm aperture enabling large isolated
More information3D-magnetic field probes AS-U3D GEO-X for ±200 µt
3D-magnetic field probes AS-U3D GEO-X for ±200 µt measurement of X, Y, Z or Σ DC and AC field measurement measurement range: ±200 µt (2 G) high bandwidth: DC 500 Hz linearity error:
More informationDifferential charge amplifier
Electronics Differential charge amplifier Type 5181A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure
More informationIntegrated Diode Laser System DioPower
Integrated Diode Laser System DioPower PC with LETSoft program DioPower Integrated Components Applications Laser Diode from 15 to 120W Material processing Laser Diode driver up to 6V / 100A Laser soldering
More informationSelective and broadband high frequency field analysis
ELECTRIC AND MAGNETIC FIELD ANALYZER EHP-200A Selective and broadband high frequency field analysis New solution for isotropic measurements in the 9 khz 30 MHz range Electric Fields from 0.02 to 1000 V/m
More information3DM-GX4-45 LORD DATASHEET. GPS-Aided Inertial Navigation System (GPS/INS) Product Highlights. Features and Benefits. Applications
LORD DATASHEET 3DM-GX4-45 GPS-Aided Inertial Navigation System (GPS/INS) Product Highlights High performance integd GPS receiver and MEMS sensor technology provide direct and computed PVA outputs in a
More informationTap Changer Analyzer & Winding Ohmmeter RMO60TT
Tap Changer Analyzer & Winding Ohmmeter RMO60TT On-load tap changer dynamic resistance measurement Three resistance measurement channels Three temperature measurement channels Automatic resistance/temperature
More information1 of 6 03/12/2012 14:56 2012-12-03 HAMEG > Products > Accessories > Probes http://www.hameg.com/186.0.html P R O B E S H Z 5 6-2 * AC/ DC Current Clamps This AC/DC Current Probe is used to measure currents
More informationRS Pro ARBITRARY/FUNCTION WAVEFORM GENERATOR SDG800 SERIES
Product Datasheet ENGLISH Stock No: 1236458 1236459 RS Pro ARBITRARY/FUNCTION WAVEFORM GENERATOR SDG800 SERIES DDS technology, Single-channel output 125MSa/s sample rate, 14bit vertical resolution. 5 types
More informationULTRASTAB I U Precision
ULTRASTAB 867-700I 867-700U Precision Current Transducer The Ultrastab 867-700I and 867-700U Current Transducers, are the latest models of the Ultrastab Current Transducers. They are the third generation
More informationDifferential Charge Amplifier
Electronics Differential Type 58A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure (IP64) Plastic
More informationManual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.
Manual Title: 5502E Getting Started Supplement Issue: 3 Part Number: 4155211 Issue Date: 9/18 Print Date: November 2012 Page Count: 12 Revision/Date: This supplement contains information necessary to ensure
More informationB-Field Scanner. BENEFITS Easy to use Fits to a wide range of voice coil gaps Fully supported by Klippel RnD System Dedicated measurement software
B-Field Scanner Accessory of the KLIPPEL R&D SYSTEM (Document Revision 1.4) FEATURES Robust & accurate Hall Probe One of the smallest Hall sensors (0.65mm thickness) available Stand-alone Gauss meter (with
More informationTWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers
TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers Resistance measurement of all tap positions in all six windings performed in a single test True three-phase on-load tap changer
More informationHigh-precision process calibrator Model CED7000
Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry
More informationEMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011
EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 All-in-one Digital EMI Analyzer 10 Hz - 3 GHz PMM 9010/30P EMI Analyzer 10 Hz - 3 GHz Our trek started in a small laboratory over 25
More informationData Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved
Data Sheet SC5317 & SC5318A 6 GHz to 26.5 GHz RF Downconverter www.signalcore.com 2018 SignalCore, Inc. All Rights Reserved Definition of Terms 1 Table of Contents 1. Definition of Terms... 2 2. Description...
More informationNI 6731/6733 Specifications
NI 6731/6733 Specifications This document lists the specifications for the NI 6731/6733 analog output devices. The following specifications are typical at 25 C unless otherwise noted. Note With NI-DAQmx,
More informationICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...
Electronics & Software ICAM Type 5073A... Industrial Charge Amplifier for Applications in Manufacturing The ICAM charge amplifier (Industrial Charge Amplifier Manufacturing) converts the piezoelectric
More informationSpectrum Analyzer. Distribution in the UK & Ireland
DSA800 Series Spectrum Analyzer All-Digital IF Technology Frequency Range from 9 khz up to 7.5 GHz Min. -161dBm Displayed Average Noise Level (Typ.) Min. < -98dBc/Hz @ 10kHz Offset Phase Noise Level Measurement
More informationGrad-13. Digital Three-Axis Gradiometer.
Grad-13 Digital Three-Axis Gradiometer www.bartington.com Grad-13 Digital Three-Axis Gradiometer Bartington Grad-13 Digital Three-Axis Gradiometer The Grad-13 provides high resolution vector measurements
More informationT10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en
T10FS Torque Flange Data Sheet Special features Nominal (rated) torques: 100 NVm, 200 NVm, 500 NVm, 1 knvm, 2 knvm, 3 knvm, 5 knvm, 10 knvm Nominal speed from 12,000 rpm to 24,000 rpm Low rotor weights
More informationFluke 5820A Oscilloscope Calibrator Specifications
Fluke 5820A Oscilloscope Calibrator Specifications Voltage Function Volt Function DC Signal Square Wave Signal 1 Load into 50Ω into 1 MΩ into 50Ω into 1 MΩ Amplitude Range 0V to ±6.6V 0V to ±130V ±1 mv
More informationContents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch
ZT530PCI & PXI Specifications Arbitrary Waveform Generator 16-bit, 400 MS/s, 2 Ch Contents Outputs... 2 Digital-to-Analog Converter (DAC)... 3 Internal DAC Clock... 3 Spectral Purity... 3 External DAC
More informationME7220A. Radar Test System (RTS) Target Simulation & Signal Analysis for Automotive Radar Exceptional Performance at an Affordable Price.
ME7220A Test System (RTS) 76 to 77 GHz Target Simulation & Signal Analysis for Automotive Exceptional Performance at an Affordable Price The Challenge The installation of collision warning and Adaptive
More informationTorque Station Pro TS-7700 System
For Motor Torque Measurement Torque Station Pro TS-7700 System The Torque Station Pro is designed to automatically measure motor torque characteristics. The compact configuration includes a built-in brake
More informationProduct Features Benefits The IMC Group Ltd.
Series Temperature monitoring The 4000T series of temperature data loggers and radio transmitters units are well established as the most flexible units on the market today. Each unit has been designed
More informationAn internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.
TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant
More informationMagnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800
IN ONE UNIT: 800W precision power amplifier, Spectrum Analyzer, Signal Generator General: The MTS-800 is a compact test system for broadband generation and measurement of magnetic fields. Its internal
More informationSpecification. Scanning Laser Range Finder C /6. Date:
Date: 2012.11.27 Scanning Laser Range Finder UTM-30LX/LN Specification 2 Correction of Repeated Accuracy Representation 3 2012.11.27 Kamon RS-0155 1 LED Display in Specificaions added 3 2012.10.23 Kamon
More informationMCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:
Extract from the online catalog MCR-C-UI-UI-DCI Order No.: 2810913 MCR 3-way isolating amplifier, with configurable I/O, for the electrical isolation of analog signals, with GL approval, preconfigured.
More informationExposure Level Tester ELT-400
Safety Evaluation within a Magnetic Field Environment Exposure Level Tester ELT-400 Direct Evaluation of Field Exposure Compared to Major Standards (IEEE C95.6) Automatic Exposure Evaluation for Various
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationSpecification. Scanning Laser Range Finder UTM-30LX/LN C /6. Date: Symbol Amendment Details Amendment Date Amended by Number
Date: 2008.04.16 Scanning Laser Range Finder UTM-30LX/LN Specification Symbol Amendment Details Amendment Date Amended by Number Approved by Checked by Drawn by Designed by MORI KAMITANI HINO Drawing.
More informationSC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.
SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter Datasheet 2017 SignalCore, Inc. support@signalcore.com P RODUCT S PECIFICATIONS Definition of Terms The following terms are used throughout this datasheet
More informationChapter 6 Specifications
Chapter 6 Specifications DC Characteristics Function Range [2] Test Current or Burden Voltage DC Voltage DC Current Resistance [6] 24 Hour [3] T CAL ±1 Accuracy Specifications: ± (% of reading + % of range)
More informationTap Changer Analyzer & Winding Ohmmeter RMO-TT
Tap Changer Analyzer & Winding Ohmmeter RMO-TT On-load tap changer dynamic resistance measurement Three resistance measurement channels Up to six temperature measurement channels Automatic resistance/temperature
More informationGPS10R - 10 MHz, GPS Disciplined, Rubidium Frequency Standards
GPS10R - 10 MHz, GPS Disciplined, Rubidium Standards Key Features Completely self-contained units. No extra P.C Multiple 10 MHz Outputs plus other outputs needed. Full information available via LCD. RS232
More informationUSB-TEMP and TC Series USB-Based Temperature Measurement Devices
USB-Based Temperature Measurement Devices Features Temperature and voltage measurement USB devices Thermocouple, RTD, thermistor, or semiconductor sensor measurements Eight analog inputs Up to ±10 V inputs*
More informationCALYS 150. Advanced documenting multifunction calibrator thermometer
Advanced documenting multifunction calibrator thermometer , most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer
More informationTap Changer Analyzer & Winding Ohmmeter RMO25TD
Tap Changer Analyzer & Winding Ohmmeter RMO25TD Test current 5 ma 25 A DC Rapid automatic demagnetization AC Current monitoring channel Lightweight 9,5 kg Measuring range 0,1-2 k Two voltage sense channels
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer IN 1000-S I P N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)
More informationXC4e PWM Digital Drive
PWM Digital Drive HyperWire fiber-optic interface Up to 30 A peak output current Integral power supply Amplifiers/Drives Drive brush, brushless, voice coil, or stepper motors Safe torque off (STO) safety
More informationAnalyzer Twin. k +49 (0) / (0) / General Agent Germany:
Combined Instrument for Quartz and Mechanical Watches This combined measurement and test instrument associates all functions of test equipments for quartz watches and test equipments for mechanical watches.
More informationCALYS 150. Advanced documenting multifunction calibrator thermometer
Advanced documenting multifunction calibrator thermometer, most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer
More informationTap Changer Analyzer & Winding Ohmmeter RMO60TD
Tap Changer Analyzer & Winding Ohmmeter RMO60TD Test current 5 ma 60 A DC Rapid automatic demagnetization AC Current monitoring channel Lightweight 13 kg Measuring range 0,1-2 k Two voltage sense channels
More informationFeatures. Description. General Specifications. VS Series Inclinometer : Dual Axis, RS232 and Analogue Output
Features Dual axis measurement from ±5 to ±60 High resolution and accuracy Low temperature drift, with optional temperature compensation to further improve temperature performance. RS232 output interface
More informationREMAGRAPH C for computer controlled measurement of the hysteresis curves of soft magnetic materials.
Page 1 / 10 REMAGRAPH C - 500 for computer controlled measurement of the hysteresis curves of soft magnetic materials Introduction The REMAGRAPH C is a fully automatic, computer controlled station to measure
More information