LUXONDES. See the electromagnetic waves. Product 2018 / 19

Size: px
Start display at page:

Download "LUXONDES. See the electromagnetic waves. Product 2018 / 19"

Transcription

1 LUXONDES See the electromagnetic waves Product 2018 / 19

2 RADIO WAVES DISPLAY The Luxondes radiofrequency to optical conversion panel directly displays the ambient EM-field or the radiation of a transmitting DUT that is placed in front of it. It comprises 400 (20x20) autonomous identical sensors working as elementary visualization pixels. Elementary antennas are printed directly on each sensor s PCB. The representation of the electromagnetic field is provided through a gradient of colors. Successive photography can provide comparisons between different testing conditions. On the side of the panel you can change the sensitivity and dynamics of the system. APPLICATION Direct mapping of the received field Antenna MIMO optimization Time reversal evaluation Energy focusing evaluation Radiation pattern observations... Technology: Digital Panel area : 1m² Number of sensor : 400 (20x20) Sensitivity : -60 dbm to 0 dbm Minimal dynamic range : 3 db Bandwidth : 50 MHz to 3 GHz Number of displayed colors : 1024 Sensitivity adjustment: Min and max threshold Real time function or delay Delay / MaxHold Number of color bar : 4 Viewing exceeded threshold Weight : 30 Kg MULTI-PANEL Area : 2, 3, 4,...9m² External control box for adjustement External synchronizing input Panel (3x3) Panel (3x2)

3 RADIO WAVES DISPLAY PC This new system for measuring and visualizing électromagnétisme radiation includes 64 sensors operating between 50 MHz and 3 GHz. Bidirectional communication (USB) is established between all sensors and a pc. This one allows to adjust in real time the sensitivity and the dynamics as well as the speed of acquisition. The software developed allows the recording and the reading of the data as well as an in-depth analysis of the results. Fast and easy to adjust, the RWD saves time in antenna radiation pattern optimization, or quality control; for example in the analysis of communication signals of connected objects or in the study of the focusing of waves (time reversal, 5G communication). It is an ideal didactic tool for teaching and a powerful communication tool for present scientific work based on electromagnetic radiation. APPLICATION Direct mapping of the received field Antenna MIMO optimization Time reversal evaluation Energy focusing evaluation (5G) Radiation pattern observations... Panel area : 45 cm x 45 cm Number of sensor : 64 (8x8) Sensitivity : -60 dbm to 0 dbm Minimal dynamic range : 3 db Bandwidth : 50 MHz to 3 GHz Number of displayed colors : 1024 Real-time adjustment of sensor sensitivity. Dynamic adjustment. ( from 60 db to 3 db ) Acquisition speed. ( max 50 frames / Sec ) Recording of data. (. bin &.dat ) Replay the data. Max Hold function. Sequence function. Graph of the average of different areas. Selection of the number of sensors displayed Direct visualization in 3D on PC acquisition of 64 sensors. Setting thresholds in real time. 3D visualization software and data analysis. Recording format.dat.bin Selection of different sensors to visualize the variation over time. Image sequence function

4 GYROSCANFIELD The Gyroscanfield is a 3D, real-time measuring equipment whose function is to directly visualize the electromagnetic radiation of a Device Under Test (DUT) in a simple and fast way. 16 sensors with detachable antennas are spread over a 60 cm diameter ring. A set of different antennas is available corresponding to your requested frequency and sensitivity ranges. Each elementary sensor around the loop converts the electromagnetic received energy in a corresponding calibrated range of visible colors by using RGB LEDs. Each sensor has an A/D converter for backup and data mining. The operation of the measuring equipment and the acquisition of data is done using an Android tablet PC. DC powering of the DUT can be performed either from the top and / or the bottom of the instrumented loop. APPLICATIONS Radiation patterns of antennas Comparison between different radiating systems Quality control Product Development Radiation measuring cables and connectors Shielding effectiveness ADVANTAGES Direct visualization of the electromagnetic field, either continuous wave or, modulated at frequencies up to several tens of µs, compatible with the time slot durations of current cellular radio standards (analog conversion). Sensors compatible with detachable antennas and the range of products LUXONDES. Fast acquisition speed Automatic recognition of maps and antennas taking into account the antenna factor Size : (H) 100 x (L) 75 x (P) 85 cm Support roller : (H) 85 cm Rotation speed : 15 Turns /sec max. Acquisition : 720 Points / Turn / Sensor Weight : 40 Kg Power supply : 230 VAC 50 Hz Comparison measurement and simulation a WiFi antenna Radar curve of the object under test 3D diagram an antenna Wireless

5 SWING ARM SCANNER The swing arm scanner allows simple and fast mapping of electromagnetic radiation. Different frequency ranges are possible upon the selected antenna card. Near field measurement of the characterization of electromagnetic pollution generated by electronic components arranged on a printed circuit activity fields is important in electromagnetic compatibility measurements. A widely used principle consits in a measuring table on which the electronic board is in operation. A controlled movement of two or three axis sensor is moved in a point to point parallel above the table in a predetermined plane mesh. Each measurement point in the mesh is stored. Then, a mapping field is built and the effective provision of the card under test is indicated on the field map obtained. This measurement requires certain precautions and a post-processing. The swing arm scanner overcomes some of these limitations by providing quick, high resolution direct measurements. The scanner is made from composite materials so as to remain neutral for EMC. APPLICATIONS Radiation measurements of an electronic card Comparison between different radiating systems Location of sources Magnet mapping (hall effect sensor) Transformer mapping (BF sensor)... Photo of the object under test Led RVB Sensor: Removable antenna board sensor card ADVANTAGES Visualization of the electromagnetic field in real time (analog conversion) Full scale digital conversion between thresholds Removable antenna cards compatible with the LUXONDES product range. Easy to use / intuitive controls Automatic recognition of antenna cards and taking into account the antenna factor Direct analysis of the results with the Androïd viewer Size : (H) 200 x (L) 700 x (P) 420 Duration for a scan A4 : 30 Sec Number of point Max X : 4000 Y : 1000/mm weight : 20 Kg Power : 230 VAC 50 Hz Visualization of results in augmented reality CI Mapping at 16MHz with and without ground plane. Cartography of a magnet with a hall sensor.

6 ELECTROMAGNETIC LENS The electromagnetic loupe can display magnetic radiation. This model has 16 sensors. Each sensor is composed of a loop and a detector whose bandwidth is between 1 and 440 MHz. The detected signals are then sampled from synchronously triggered by an internal trigger. The visualization is performed with leds positioned above each sensor. Two potentiometers are used to adjust the low threshold and the high threshold to always get the maximum visible dynamics. APPLICATIONS Direct mapping of the field Location of point radiation Screening comparison Antenna emission comparison Follow-up of a disturbance Realization of practical work (teaching)... EDUCATION -Pratical work Magnetic field in a coil Checking shield, ground plane Radiation of an electronic card (CM PC) Coupling between two coils Communicating objects (433MHz) Remote controls, module 433, magnetic sensors Setting the dynamic range in dbv. ( Sensitivity of sensors ) Technology: Digital Case size: 20 x 25 x 6 cm Size of a sensor: 1 x 1 cm Number of sensors: 16 Sensitivity: -91 dbv to +4 dbv Dynamic min: 3 db Bandwidth: 1 MHz to 440 MHz Sensitivity adjustment: min threshold and max Threshold technologie : numérique Coil of N turns Frequency generator Exemple TP Dynamic SETTINGS Min threshold and Max threshold Magnetic field H Visualization of the magnetic field radiated by a coil in function: Number of turns Diameter of the coil Frequency, Amplitude,...

7 SENSORS - ANTENNA CARD Antenna cards are built according to a standard format smart card. They include the antenna and the RF detector. For specific applications, we realize the HF portion (Amplifier, filters,...)

8 ANDROID APPLICATION XML / NFS standard The XML / NFS standard: TR IEC: 2010 will define a universal interchange format for data from different Near Field Scan (Near Field Scan). Its format is suitable for different 2D or 3D coordinate systems for a frequency or temporary domain. SIMPLE VIEWER Direct reading of data from: Gyroscanfield, CT Scanner, Kinect XML format import, OBJ, FFS. Data comparison between DATA1 and 2. Multi-frequency analysis. Visualization of the object under test (image / obj 3D). 2D chart for planar data. Radar graph for spherical data. CUT function for spherical data. Compatible coordinates: Cartesian, cylindrical and spherical. Compatible format: Amplitude Phase, Real Imaginary. Specific Mir display values greater than zero.... QRCODE FUNCTION Paste a QRCode on the object under test and download the measurements directly with the viewer. Insert a QRCode into your reports. Download examples on the luxondes website. direct comparison measurement and simulation 3d radiation diagram of a wifi antenna planar mapping inside a vehicle AUGMENTED REALITY Visualization of measurements in RA. Sectional view of 3D diagram. Real mapping of the EM environment. Compare the evolution of measurements over time. Compare measurement simulation on the object under test. Visualization of measurements in Augmented Reality

EMI Pre-Compliance Testing Solution

EMI Pre-Compliance Testing Solution 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com EMI Pre-Compliance Testing Solution GW Instek introduces the latest and comprehensive

More information

EMC-scanner. HRE-series. See it before you CE it!

EMC-scanner. HRE-series. See it before you CE it! EMC-scanner HRE-series See it before you CE it! Print Screen image of a scan measurement. Seeing high frequencies! Now you can SEE high frequency electro magnetic fields. The background There are high

More information

Spectrum Analyzers 2680 Series Features & benefits

Spectrum Analyzers 2680 Series Features & benefits Data Sheet Features & benefits n Frequency range: 9 khz to 2.1 or 3.2 GHz n High Sensitivity -161 dbm/hz displayed average noise level (DANL) n Low phase noise of -98 dbc/hz @ 10 khz offset n Low level

More information

4GHz / 6GHz Radiation Measurement System

4GHz / 6GHz Radiation Measurement System 4GHz / 6GHz Radiation Measurement System The MegiQ Radiation Measurement System (RMS) is a compact test system that performs 3-axis radiation pattern measurement in non-anechoic spaces. With a frequency

More information

Where Safety Matters, Use The Latest Technology

Where Safety Matters, Use The Latest Technology Electromagnetic Safety Equipment Where Safety Matters, Use The Latest Technology 146 Electromagnetic radiation is becoming more of a safety concern to individuals as well as workers. Dedicated RF safety

More information

Electromagnetic Field Measurement System

Electromagnetic Field Measurement System Electromagnetic Field Measurement System Electromagnetic Field Measurement System Magnetic Near Field Probes Low-frequency (Active Probes) Low-frequency, High-current, Wideband High-frequency (GHz), Wideband

More information

NHT 3DL. The new landmark meter for electromagnetic safety. Percipere Aestimare et Inquirere

NHT 3DL. The new landmark meter for electromagnetic safety. Percipere Aestimare et Inquirere NHT 3DL The new landmark meter for electromagnetic safety Percipere Aestimare et Inquirere NHT 3DL The new reference meter for the European directive 2013/35/EU NHT 3DL is a brand-new electromagnetic field

More information

Active System for Electromagnetic Perturbation Monitoring in Vehicles

Active System for Electromagnetic Perturbation Monitoring in Vehicles Active System for Electromagnetic Perturbation Monitoring in Vehicles Adrian Marian Matoi and Elena Helerea Transilvania University of Brasov, Eroilor Bvd. 29, 500036 Brasov, Romania matoi@unitbv.ro, helerea@unitbv.ro

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) R3000 EMI TEST RECEIVERS Fully IF digital EMI Receivers family for measurement of electromagnetic interference from

More information

PB T/R Two-Channel Portable Frequency Domain Terahertz Spectrometer

PB T/R Two-Channel Portable Frequency Domain Terahertz Spectrometer Compact, Portable Terahertz Spectroscopy System Bakman Technologies versatile PB7220-2000-T/R Spectroscopy Platform is designed for scanning complex compounds to precise specifications with greater accuracy

More information

Millimeter Wave Measurement System

Millimeter Wave Measurement System Millimeter Wave Measurement System Testing Existing and Upcoming Technologies FREQUENCY RANGE Supports Millimeter Wave Frequencies and Bandwidths 18 to 26.5 GHz 26.5 to 40 GHz 33 to 50 GHz 40 to 60 GHz

More information

5G ANTENNA TEST AND MEASUREMENT SYSTEMS OVERVIEW

5G ANTENNA TEST AND MEASUREMENT SYSTEMS OVERVIEW 5G ANTENNA TEST AND MEASUREMENT SYSTEMS OVERVIEW MVG, AT THE FOREFRONT OF 5G WIRELESS CONNECTIVITY! VISION The connected society enabled by 5G Smart cities Internet of Things 5G lays the foundation for

More information

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES Frequency range: 9 khz - 6.5 or 8.5 GHz Measured parameters: S11, S12, S21, S22 Wide output power adjustment range: -50 dbm to +5 dbm

More information

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz* SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz* SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM MRI Shielding Environment

More information

EMC Near-field Probes + Wideband Amplifier

EMC Near-field Probes + Wideband Amplifier 1 Introduction The H20, H10, H5 and E5 are magnetic field (H) and electric field (E) probes for radiated emissions EMC precompliance measurements. The probes are used in the near field of sources of electromagnetic

More information

T- DualScan. StarLab

T- DualScan. StarLab T- DualScan StarLab StarLab is the ultimate tool for antenna pattern measurements in laboratories and production environments where space is limited, cost is critical, and the flexibility of a portable

More information

Part No. ETH-MMW-1000 (version 1A) Millimeter Measurement System Frequency Range: 18 GHz 75 GHz

Part No. ETH-MMW-1000 (version 1A) Millimeter Measurement System Frequency Range: 18 GHz 75 GHz DATASHEET (v1.5) Part No: ETH-MMW-1000 (version 1A) Product: Millimeter Measurement System Part No. ETH-MMW-1000 (version 1A) Millimeter Measurement System Frequency Range: 18 GHz 75 GHz Ethertronics presents

More information

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz* SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz* MRI Shielding Environment (Magnetic Resonance Imaging) Shielded and anechoic

More information

ELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS

ELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS Academic Year 2015-2016 ELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS V. BEAUVOIS P. BEERTEN C. GEUZAINE 1 CONTENTS: EMC laboratory session 1: EMC tests of a commercial Christmas LED light

More information

DSA700 Series Spectrum Analyzer

DSA700 Series Spectrum Analyzer DSA700 Series Spectrum Analyzer Product Features: All-Digital IF Technology Frequency Range from 100 khz up to 1 GHz Min. -155 dbm Displayed Average Noise Level (Typ.) Min.

More information

Debugging EMI Using a Digital Oscilloscope. Dave Rishavy Product Manager - Oscilloscopes

Debugging EMI Using a Digital Oscilloscope. Dave Rishavy Product Manager - Oscilloscopes Debugging EMI Using a Digital Oscilloscope Dave Rishavy Product Manager - Oscilloscopes 06/2009 Nov 2010 Fundamentals Scope Seminar of DSOs Signal Fidelity 1 1 1 Debugging EMI Using a Digital Oscilloscope

More information

TEST REPORT. Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF. FCC Part 15 Subpart E (UNII) Xirrus Model(s): XN4

TEST REPORT. Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF. FCC Part 15 Subpart E (UNII) Xirrus Model(s): XN4 TEST REPORT Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF FCC Part 15 Subpart E (UNII) Xirrus Model(s): XN4 COMPANY: TEST SITE: Xirrus 370 North Westlake Blvd., Suite 200 Westlake Village,

More information

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 All-in-one Digital EMI Analyzer 10 Hz - 3 GHz PMM 9010/30P EMI Analyzer 10 Hz - 3 GHz Our trek started in a small laboratory over 25

More information

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc. P a g e 1 ST985 TDR Cable Analyzer Instruction Manual Analog Arts Inc. www.analogarts.com P a g e 2 Contents Software Installation... 4 Specifications... 4 Handling Precautions... 4 Operation Instruction...

More information

Ileana-Diana Nicolae ICMET CRAIOVA UNIVERSITY OF CRAIOVA MAIN BUILDING FACULTY OF ELECTROTECHNICS

Ileana-Diana Nicolae ICMET CRAIOVA UNIVERSITY OF CRAIOVA MAIN BUILDING FACULTY OF ELECTROTECHNICS The Designing, Realization and Testing of a Network Filter used to Reduce Electromagnetic Disturbances and to Improve the EMI for Static Switching Equipment Petre-Marian Nicolae Ileana-Diana Nicolae George

More information

PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet

PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet The most important thing we build is trust 250 MHz to 6 GHz RF signal conditioning module for multi- UE, MIMO and Smartphone testing Four full

More information

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave. 20 Amplifiers 83020A microwave 875A microwave 8308A microwave 8307A microwave 83006A microwave 8705C preamplifier 8705B preamplifier 83050/5A microwave The Agilent 83006/07/08/020/050/05A test s offer

More information

3 Phase Power Quality Analy er

3 Phase Power Quality Analy er 3 Phase Power Quality Analy er BlackBox G4500 The 3 Phases Portable Power Quality Analyzers Discover Outstanding Features The BlackBox portable series power quality analyzer takes power quality monitoring

More information

The Precision Spherical Dipole Source

The Precision Spherical Dipole Source The Precision Spherical Dipole Source Freedom to make accurate and repeatable measurements!! Presented by: Bruce Archambeault, Ph.D. Partner / Technical Director bruce@appliedemtech.com (AET) Mission:

More information

Appendix A: Specifications

Appendix A: Specifications Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Appendix A: Specifications This section provides a complete description of the video measurement set specifications.

More information

PMM 7010 EMI RECEIVERS. The EMI Receiver with built-in LISN

PMM 7010 EMI RECEIVERS. The EMI Receiver with built-in LISN The EMI Receiver with built-in LISN 1 Model Frequency Range 7010/00 150 khz to 1 GHz 7010/01 9 khz to 1 GHz 7010/02 9 khz to 30 MHz 7010/03 9 khz to 3 GHz 2 family Built-in 16 A single phase LISN Artificial

More information

Saturation of Active Loop Antennas

Saturation of Active Loop Antennas Saturation of Active Loop Antennas Alexander Kriz EMC and Optics Seibersdorf Laboratories 2444 Seibersdorf, Austria Abstract The EMC community is working towards shorter test distances for radiated emission

More information

Software. Equipment. Add-ons. Accessories. Services

Software. Equipment. Add-ons. Accessories. Services T- DualScan FScan FScan is a vertical near-field planar scanner system that is a perfect solution for antenna measurement applications where a phased array, high gain, or reflector antenna is under evaluation.

More information

Course Introduction Purpose Objectives Content Learning Time

Course Introduction Purpose Objectives Content Learning Time Course Introduction Purpose This course discusses techniques for analyzing and eliminating noise in microcontroller (MCU) and microprocessor (MPU) based embedded systems. Objectives Learn about a method

More information

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 2.8GHz.

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 2.8GHz. ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 2.8GHz. Compact designed and manufactured in compliance with CISPR 16-1-1 For Measurements

More information

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF Definition of ElectroMagnetic Compatibility (EMC) EMC is defined as: "The ability of devices and

More information

Investig&ion of the Theoretical Basis for Using a 1 G& TEM Cell to Evaluate the Radiated Emissions from Integrated Circuits

Investig&ion of the Theoretical Basis for Using a 1 G& TEM Cell to Evaluate the Radiated Emissions from Integrated Circuits Investig&ion of the Theoretical Basis for Using a 1 G& TEM Cell to Evaluate the Radiated Emissions from Integrated Circuits James P. Muccioli JASTECH P.O. Box 3332 Farmington Hills, MI 48333 Terty M. North

More information

DATES OF TESTS: From 03/10/2014 to 20/10/2014 and 25/02/2015. Open area test site in Aunainville (28) - FRANCE. Page 2 out of 54

DATES OF TESTS: From 03/10/2014 to 20/10/2014 and 25/02/2015. Open area test site in Aunainville (28) - FRANCE. Page 2 out of 54 TEST CERTIFICATION FOR: FCC Certification NAME OF THE EQUIPMENT UNDER TEST: Serial number: Wireless conference access point Type: CONFIDEA WCAP G3 1440077150000C1 Reference / model (P/N): 71.98.0033 V

More information

SAS-563B Active Loop Antenna Operation Manual

SAS-563B Active Loop Antenna Operation Manual SAS-563B Active Loop Antenna Operation Manual 1 TABLE OF CONTENTS INTRODUCTION 3 SPECIFICATIONS 5 OPERATING INSTRUCTIONS 7 CALCULATIONS 11 ANTENNA FORMULAS 12 MAINTENANCE 13 WARRANTY 14 2 INTRODUCTION

More information

Investigation of a Voltage Probe in Microstrip Technology

Investigation of a Voltage Probe in Microstrip Technology Investigation of a Voltage Probe in Microstrip Technology (Specifically in 7-tesla MRI System) By : Mona ParsaMoghadam Supervisor : Prof. Dr. Ing- Klaus Solbach April 2015 Introduction - Thesis work scope

More information

6 Electromagnetic Field Distribution Measurements using an Optically Scanning Probe System

6 Electromagnetic Field Distribution Measurements using an Optically Scanning Probe System 6 Electromagnetic Field Distribution Measurements using an Optically Scanning Probe System TAKAHASHI Masanori, OTA Hiroyasu, and ARAI Ken Ichi An optically scanning electromagnetic field probe system consisting

More information

GSP303D 3-Axis Digital Magnetic Field Transmitter

GSP303D 3-Axis Digital Magnetic Field Transmitter Digital Handheld Magnetic Transmitter Transmitter Field Transmitter GSP303D 3-Axis Digital Magnetic Field Transmitter Digital Output (RS485) Accuracy Based on Reading (Not Range) Wide Supply Power: 5 to

More information

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz Compact designed and manufactured in compliance with CISPR 16-1, For Measurements

More information

Measuring Photonic, Optoelectronic and Electro optic S parameters using an advanced photonic module

Measuring Photonic, Optoelectronic and Electro optic S parameters using an advanced photonic module Measuring Photonic, Optoelectronic and Electro optic S parameters using an advanced photonic module APPLICATION NOTE This application note describes the procedure for electro-optic measurements of both

More information

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges) PERFORMANCES 12 ranges of AC current from 16 ma to 128 A peak AC permanent current up to 26 ARMS Nine ranges of DC permanent current from 16 ma to 12 A DC current ± 6mA or ± 10 ma stackable to AC current

More information

Electromagnetic Compatibility

Electromagnetic Compatibility Electromagnetic Compatibility Introduction to EMC International Standards Measurement Setups Emissions Applications for Switch-Mode Power Supplies Filters 1 What is EMC? A system is electromagnetic compatible

More information

and GHz. ECE Radiometer. Technical Description and User Manual

and GHz. ECE Radiometer. Technical Description and User Manual E-mail: sales@elva-1.com http://www.elva-1.com 26.5-40 and 76.5-90 GHz ECE Radiometer Technical Description and User Manual November 2008 Contents 1. Introduction... 3 2. Parameters and specifications...

More information

FFT 3010 EMI TEST RECEIVER

FFT 3010 EMI TEST RECEIVER FFT 3010 EMI TEST RECEIVER Fully FFT digital EMI Receiver for measurement of conducted electromagnetic interference from 9kHz to 30MHz Compact designed and manufactured compliant to CISPR 16 International

More information

EMC Test Report. Report Number: M030826

EMC Test Report. Report Number: M030826 Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report

More information

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer ShinewayTech CAA-100A cable & antenna analyzer with spectrum analyzer can test DTF/Frequency Return Loss, VSWR, Cable Loss, RF Power and Spectrum.

More information

VDE Testing and Certification Institute. Contents Directory

VDE Testing and Certification Institute. Contents Directory Contents Directory 1 Description of the sample (EUT)...3 1.1 General description...3 1.2 Technical Specifications...4 1.2.1 Transmitter...4 2 Summary of test results...8 2.1 Transmitter test results...8

More information

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009 EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009 Our trek started in a small laboratory over 25 years ago. Since then, we ve been focused on making EMC measurements easier and the measuring

More information

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power

More information

Specification. Scanning Laser Range Finder C /6. Date:

Specification. Scanning Laser Range Finder C /6. Date: Date: 2012.11.27 Scanning Laser Range Finder UTM-30LX/LN Specification 2 Correction of Repeated Accuracy Representation 3 2012.11.27 Kamon RS-0155 1 LED Display in Specificaions added 3 2012.10.23 Kamon

More information

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION) 147 CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION) 6.1 INTRODUCTION The electrical and electronic devices, circuits and systems are capable of emitting the electromagnetic

More information

Your Network. Optimized.

Your Network. Optimized. Over 20 years of research both at the National Institute of Standards and Technology (NIST) and in private industry have been dedicated to the research and development of Symmetricom s phase noise and

More information

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay year Product Brochure Version 0.00 R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE 80.ad and IEEE 80.ay NRPM_bro_en_607-4687-_v000.indd 8.0.09 5:59:08 R&S NRPM Over-the-Air (OTA)

More information

Accutech AM20. Wireless acoustic monitor field unit

Accutech AM20. Wireless acoustic monitor field unit Accutech AM20 Wireless acoustic monitor field unit 1 The Accutech AM20 wireless acoustic monitor field unit monitors pressure relief valves, steam traps, automatic tank cleaning (CIP) systems, and other

More information

Measurement Environment Influence Compensation to Reproduce Anechoic Chamber Measurements with Near Field Scanning

Measurement Environment Influence Compensation to Reproduce Anechoic Chamber Measurements with Near Field Scanning Measurement Environment Influence Compensation to Reproduce Anechoic Chamber Measurements with Near Field Scanning Denis Rinas, Alexander Zeichner, Stephan Frei TU Dortmund University Dortmund, Germany

More information

SAS-562B Active Loop Antenna Operation Manual

SAS-562B Active Loop Antenna Operation Manual SAS-562B Active Loop Antenna Operation Manual 1 TABLE OF CONTENTS INTRODUCTION 3 SPECIFICATIONS 5 OPERATING INSTRUCTIONS 7 CALCULATIONS 11 ANTENNA FORMULAS 12 MAINTENANCE 13 WARRANTY 14 2 INTRODUCTION

More information

System configurations. Main features I SG 64 SOLUTION FOR

System configurations. Main features I SG 64 SOLUTION FOR T- DualScan SG 64 The most accurate solution for testing antennas and wireless devices: SG 64 has been developed to measure stand alone antennas or antennas integrated in subsystems. It is also ideal for

More information

R&S NRP-Zxx Power Sensors Specifications

R&S NRP-Zxx Power Sensors Specifications R&S NRP-Zxx Power Sensors Specifications year Data Sheet Version 11.00 CONTENTS Definitions... 3 Overview of the R&S NRP-Zxx power sensors... 4 Specifications in brief of the R&S NRP-Zxx power sensors...

More information

PB T/R Two-Channel Portable Frequency Domain Terahertz Spectrometer

PB T/R Two-Channel Portable Frequency Domain Terahertz Spectrometer PB7220-2000-T/R Two-Channel Portable Frequency DATASHEET MA 2015 Compact, Portable Terahertz Spectroscopy System Bakman Technologies versatile PB7220-2000-T/R Spectroscopy Platform is designed for scanning

More information

FISCHER CUSTOM COMMUNICATIONS, INC.

FISCHER CUSTOM COMMUNICATIONS, INC. FISCHER CUSTOM COMMUNICATIONS, INC. Current Probe Catalog FISCHER CUSTOM COMMUNICATIONS, INC. Fischer Custom Communications, Inc., is a manufacturer of custom electric and magnetic field sensors for military

More information

RF Test Accessories. Antenna Coupler. TC-93010C fitted with F930102A TC-93013A. Frequency Range : 820 ~ 960 MHz. Frequency Range : 0.

RF Test Accessories. Antenna Coupler. TC-93010C fitted with F930102A TC-93013A. Frequency Range : 820 ~ 960 MHz. Frequency Range : 0. RF Test Accessories Antenna Coupler TC-93010C Tubular Type Antenna Coupler Frequency Range : 0.8 ~ 2GHz RF Connector : SMA(f) Weight : 60g Patent Pending # 2001-24403 Hole Size : 11mm TC-93010C fitted

More information

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7 Ultra Wide Band test setup System description 1. UWB TEST SYSTEM DESCRIPTION... 2 2. SYSTEM MONITORING... 5 3. OTHER MEASUREMENT SYSTEMS & ACCESSORIES... 6 3.1 OSCILLOSCOPE & SHIELDED ENCLOSURE... 6 3.2

More information

System configurations. Main features. I TScan SOLUTION FOR

System configurations. Main features. I TScan SOLUTION FOR TScan TScan is a fast and ultra-accurate planar near-field scanner with the latest motor drive and encoder technologies. High acceleration of the linear motors for stepped and continuous mode operation

More information

Chapter 12 Digital Circuit Radiation. Electromagnetic Compatibility Engineering. by Henry W. Ott

Chapter 12 Digital Circuit Radiation. Electromagnetic Compatibility Engineering. by Henry W. Ott Chapter 12 Digital Circuit Radiation Electromagnetic Compatibility Engineering by Henry W. Ott Forward Emission control should be treated as a design problem from the start, it should receive the necessary

More information

This is a preview - click here to buy the full publication

This is a preview - click here to buy the full publication TECHNICAL REPORT IEC TR 63170 Edition 1.0 2018-08 colour inside Measurement procedure for the evaluation of power density related to human exposure to radio frequency fields from wireless communication

More information

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference Issue 3, October 2002 Electromagnetic Compatibility and Electrical Safety Contents Telcordia GR-1089 - Documentation Information Generic Requirements Notice Of Disclaimer................. iii Contents.......................................

More information

Analog signal generator that meets virtually every requirement

Analog signal generator that meets virtually every requirement GENERAL PURPOSE 44434/5 FIG 1 The R&S SMA1A offers excellent performance and compact design at a favorable price. Signal Generator R&S SMA1A Analog signal generator that meets virtually every requirement

More information

EM-ISight Electromagnetic Scanning System. Since Page 1 of 6 Phone (613) Fax (613)

EM-ISight Electromagnetic Scanning System. Since Page 1 of 6   Phone (613) Fax (613) Since 1981 EM-ISight Electromagnetic Scanning System Page 1 of 6 EM-ISight ALSAS EM7 APREL Laboratories is a pioneer in the area of automated system solutions and is pleased to introduce EM-ISight which,

More information

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks GB Technical data Issue 06/2009 PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks Fault detection Evaluation of voltage quality according to EN50160 and IEC61000-2-2 Fault recorder

More information

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm) Page 41 of 103 9.6. Test Result The test was performed with 802.11b Channel Frequency (MHz) power ANT 1(dBm) power ANT 2 (dbm) power ANT 1(mW) power ANT 2 (mw) Limits dbm / W Low 2412 7.20 7.37 5.248 5.458

More information

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point 2010 MAP Range HV / MV / LV electrical network quality analyzers Class A > Network quality Analyzers PRODUCT ADVANTAGES COMPLIANT with the EN 61000-4-30 standard, Class A DETECTION of the fault LOCATION

More information

Fluke 3540 FC Three-Phase Power Monitor

Fluke 3540 FC Three-Phase Power Monitor Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com TECHNICAL DATA Fluke 3540 FC Three-Phase Power Monitor THREE-PHASE MONITORING AND STREAMING Monitor three-phase

More information

SEMASPEC Provisional Test Method for Evaluating the Electromagnetic Susceptibility of Thermal Mass Flow Controllers

SEMASPEC Provisional Test Method for Evaluating the Electromagnetic Susceptibility of Thermal Mass Flow Controllers SEMASPEC Provisional Test Method for Evaluating the Electromagnetic Susceptibility of Thermal Mass Flow Controllers Technology Transfer 92071231B-STD and the logo are registered service marks of, Inc.

More information

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer. Spectrum Analyzers 2394A 1 khz to 13.2 GHz Spectrum Analyzer A spectrum analyzer with outstanding performance and a user friendly visual interface simplifying many complex measurements 1 khz to 13.2 GHz

More information

Measurement of Digital Transmission Systems Operating under Section March 23, 2005

Measurement of Digital Transmission Systems Operating under Section March 23, 2005 Measurement of Digital Transmission Systems Operating under Section 15.247 March 23, 2005 Section 15.403(f) Digital Modulation Digital modulation is required for Digital Transmission Systems (DTS). Digital

More information

UNIVERSITI MALAYSIA PERLIS

UNIVERSITI MALAYSIA PERLIS UNIVERSITI MALAYSIA PERLIS SCHOOL OF COMPUTER & COMMUNICATIONS ENGINEERING EKT 341 LABORATORY MODULE LAB 2 Antenna Characteristic 1 Measurement of Radiation Pattern, Gain, VSWR, input impedance and reflection

More information

Amplifier Characterization in the millimeter wave range. Tera Hertz : New opportunities for industry 3-5 February 2015

Amplifier Characterization in the millimeter wave range. Tera Hertz : New opportunities for industry 3-5 February 2015 Amplifier Characterization in the millimeter wave range Tera Hertz : New opportunities for industry 3-5 February 2015 Millimeter Wave Converter Family ZVA-Z500 ZVA-Z325 Y Band (WR02) ZVA-Z220 J Band (WR03)

More information

Fluke 3540 FC Three-Phase Power Monitor

Fluke 3540 FC Three-Phase Power Monitor TECHNICAL DATA Fluke 3540 FC Three-Phase Power Monitor The 3540 FC Three-Phase Power Monitor is a compact device to monitor three-phase systems and stream data to the Fluke Connect Cloud. The measurement

More information

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer

More information

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound MultiScan MS 5800 Tube Inspection System Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound 920-107 MultiScan MS 5800 E Tube Inspection with Eddy Current Condensers

More information

Test Report No

Test Report No x Test Report No.8312314587 For Synel Industries Ltd. Equipment Under Test: Proximity Reader From The Standards Institution Of Israel Industry Division Telematics Laboratory EMC Section Certificate No.

More information

Localization and Identifying EMC interference Sources of a Microwave Transmission Module

Localization and Identifying EMC interference Sources of a Microwave Transmission Module Localization and Identifying EMC interference Sources of a Microwave Transmission Module Ph. Descamps 1, G. Ngamani-Njomkoue 2, D. Pasquet 1, C. Tolant 2, D. Lesénéchal 1 and P. Eudeline 2 1 LaMIPS, Laboratoire

More information

Product Description. Theory of operation

Product Description. Theory of operation TC-5062C 6 GHz TEM Cell Product TC-5062C, 6 GHz TEM Cell generates the Electro-Magnetic field for testing small RF devices such as wireless communication receiver, Mobile phone, etc An external test signal

More information

Component Test. All Test Equipment in this category can be linked to PC. Comparison Function. Graphic Scan Function Bin Sorting Function

Component Test. All Test Equipment in this category can be linked to PC. Comparison Function. Graphic Scan Function Bin Sorting Function Component Test All Test Equipment in this category can be linked to PC Software test data collection, analysis, and production report capabilities RS-232 cable connection Test Data Results stored on PC

More information

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound MultiScan MS 5800 Tube Inspection System 920-107 Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound MultiScan MS 5800 E Tube Inspection with Eddy Current Condensers

More information

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System DRTS-6 Advanced Protection Relay Test Set and Measurement System MULTI-TASKING EQUIPMENT DESIGNED FOR TESTING PROTECTION RELAYS, ENERGY METERS, TRANSDUCERS POWERFUL AND LIGHTWEIGHT HIGH ACCURACY: BETTER

More information

Flexible AC current probes

Flexible AC current probes Flexible AC current probes Making use of the principle of Rogowski coils, the MiniFLEX models are flexible sensors offering a wide dynamic range for measuring AC intensities and viewing high-speed current

More information

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS SYNTHESIZED SIGNAL GENERATOR MG3641A/MG3642A 12 khz to 1040/2080 MHz NEW New Anritsu synthesizer technology permits frequency to be set with a resolution of 0.01 Hz across the full frequency range. And

More information

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission Core-6 EMI Receiver 9 khz 6 GHz Features: Frequency ranges: 9 khz 30 MHz and 30 MHz 6 GHz Fully compliant acc. to CISPR 16-1-1

More information

MRI & NMR spectrometer

MRI & NMR spectrometer AMOS MRI & NMR spectrometer The AMOS Spectrometer is a highly modular and flexible unit that provides the ability to customize synchronized configurations for preclinical and clinical MR applications.

More information

Effectively Using the EM 6992 Near Field Probe Kit to Troubleshoot EMI Issues

Effectively Using the EM 6992 Near Field Probe Kit to Troubleshoot EMI Issues Effectively Using the EM 6992 Near Field Probe Kit to Troubleshoot EMI Issues Introduction The EM 6992 Probe Kit includes three magnetic (H) field and two electric (E) field passive, near field probes

More information

ARCO 400. Technical Data

ARCO 400. Technical Data Technical Data OMICRON electronics GmbH 2017. All rights reserved. This technical data was extracted from the following manual: ENU 1119 04 03 All rights including translation reserved. Reproduction of

More information

FlexRay Communications System. Physical Layer Common mode Choke EMC Evaluation Specification. Version 2.1

FlexRay Communications System. Physical Layer Common mode Choke EMC Evaluation Specification. Version 2.1 FlexRay Communications System Physical Layer Common mode Choke EMC Evaluation Specification Version 2.1 Disclaimer DISCLAIMER This specification as released by the FlexRay Consortium is intended for the

More information

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual IT-24 RigExpert 2.4 GHz ISM Band Universal Tester User s manual Table of contents 1. Description 2. Specifications 3. Using the tester 3.1. Before you start 3.2. Turning the tester on and off 3.3. Main

More information

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3 Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3 GHz Magnetic fields monitoring from 10 Hz to 5 khz Automatic

More information

TECHNICAL SPECIFICATION FOR RF (TEST &MEASUREMENT) DEVICE

TECHNICAL SPECIFICATION FOR RF (TEST &MEASUREMENT) DEVICE TECHNICAL SPECIFICATION FOR RF (TEST &MEASUREMENT) DEVICE Test and measuring device supports the following measurement functions: A- Cable and Antenna Analyzer, 2 MHz to 4 GHz. B- Spectrum Analyzer, 100

More information