ControlEdge 900 Platform Modules Specifications

Size: px
Start display at page:

Download "ControlEdge 900 Platform Modules Specifications"

Transcription

1 ControlEdge 00 Platform Modules Specifications , September Overview The Honeywell ControlEdge HC00 Controller is an advanced loop and logic controller offering a modular design sized to satisfy the control and data acquisition needs of a wide range of process equipment. I/O Modules The following I/O modules are available to create a custom control solution. Channel Universal IO Module Galavanically isolated Input/Output to chassis (p.) -point universal analog input modules: Galvanic isolation point to chassis inputs may be mixed on a module and may include multiple thermocouple types, RTDs, ohms, voltage or mill voltage types all easily assigned using the Process Control Designer configuration tool. High point-to-point galvanic isolation simplifies installation and saves the expense of external isolation hardware (p.). -point high level analog input module: each point is configurable for V or ma. Galvanically isolated point to chassis. Galvanically isolated point to point (p.0). 50- ohm shunt resistors can be added per channel. -point galvanically isolated analog output module. Galvanically isolated point to chassis supports from 0 to ma each (p.). -point analog output, galvanically isolated in groups of points. Galvanically isolated point to chassis. Supports from 0 to ma each (p.). -point analog output, galvanically isolated in groups of points. Galvanically isolated point to chassis. Supports from 0 to ma each (p.). -point digital input modules: Contact closure type, DC Voltage, AC Voltage and AC/DC voltage types (p.5). Galvanically isolated in groups of channel to chassis -point digital input module: DC voltage. Galvanically isolated point to chassis. Galvanically isolated in groups of points (p.5). -point AC or -point DC digital output modules (sinking type). Galvanically isolated point to chassis. Galvanically isolated in groups of points (p.). -point digital output: DC voltage (sourcing type). Galvanically isolated point to chassis. Galvanically isolated in groups of points (p.). -point relay output module: four form C type and four form A type relays. Galvanically isolated point to chassis. Galvanically isolated relay to relay (p.). channel Pulse/Frequency/Quadrature I/O module. Galvanically isolated point to chassis (p.). Insert and Removal of I/O under Power For ease of maintenance, the ControlEdge HC00 controller supports removing and inserting I/O modules from the module rack without removing power from the controller. Each module is sensed for validity by the controller and auto-configured on insertion. Other Modules In addition to I/O, the following modules are available. Failsafe Scanner module, single port (p.) Scanner Module, dual port (p.) Universal AC Power Supply, 0W (p.) Power Supply VDC, 0W (p.) Redundant Switch Module (p.) Power Status Module (p.) All ControlEdge 00 Platform I/O modules support a user specified failsafe value (analog) or state (digital) that the module outputs or inputs will assume if communication between the controller and the module is interrupted. Output modules are also disabled if the controller fails to start. Module diagnostics are not initiated if the control strategy does not call for the inputs or outputs on the modules to execute. Failsafe is restricted to de-energize in safety applications.

2 ControlEdge 00 Platform Modules Remote Terminal Panels Optional DIN rail mounted Remote Terminal Panels (RTPs) are available for use with pre-wired cables to reduce installation time and labor expense. Three types of RTPs are available: analog inputs, relay outputs, and other I/O modules. Three cable lengths are also available to match hardware to installation variations. Analog inputs RTPs include transmitter shunt resistors and transmitter power terminals with individual circuit fuses. The Relay Output RTP includes a fuse and power disconnect switch for each output. All the three types of RTP panels also switch power to allow module removal and installation under controller power. See page. Terminal Blocks -screw Barrier style and Euro style terminal blocks are available for use with all ControlEdge HC00 I/O Modules. Red terminal blocks are used for high voltage connections for added safety while black terminal blocks are used for low voltage connections. A -terminal Euro style block is available with the AI, the and AO as well as the DC DI and DC DO module types. See page. Specifications for modules I/O Module Attributes Remove & Insert under power LED Channel State indicators LED Module Status indicator I/O Labels Processor Terminal Boards Standard. Modules are automatically sensed and configured on insertion. Field power shall be disconnected before removing field terminal blocks. Via light pipes at front of module, one state LED for each digital I/O point green indicates ON, logic side Via light pipe, one per module, tri-color to represent module status, Green = OK, Red = Fault (# of flashes indicates fault), Amber = Override (Force) Color-coded, on module door, removable, with write-on area to label I/O Micro-controller per module for parallel processing screw: Barrier or Euro style, tin-plated or gold-plated (for DC connections) screw: Euro style gold plated (Required with certain higher capacity modules) Keying Environmental and Vibration Specifications Mounting Standard 5mm wide DIN Rail Hardware keying matches each module to its terminal block with its field wiring. Provides connection of field wiring to controller I/O within an enclosure only. Dimensions. (. mm) x.0 (.0mm) x.0 (.0mm) (L x W x H) Vibration Amplitude Acceleration Vibration Tray material Tray and end caps Flammability Environmental Temperature Relative Humidity Harsh Environment ** ROHS** ** Except PSU module 5Hz to 5.Hz,.0mm (0.0 ) amplitude (peak to peak) 5. to 50Hz,.0-g Sweeping, at rate of. octave/min. Polyvinyl Chloride (PVC) UL-V0 Operating: 0 deg. C (F) to 0 deg. C (0F) Storage: -0 deg. C (0F) to 0 deg. C (5F) Operating: 0% to 0% Non-condensing Storage: 5% to 5% Non-condensing All the modules including CPU, Scanner, PSU, RTP, Backplane, RSM/PSM, and Backplanes have conformal coating that is suitable for operation in G level of harsh environment. Entire system is compliant to RoHS directive

3 ControlEdge 00 Platform Modules Certifications CE EN-:, EN--:0, EN550:0/A,0, EN00-:0 UL Certificate: E UL Listed- Process Control Equipment, Electrical UL 00- nd Edition ATEX Certificate: HON 0.0 II G Ex na IIC T* Gc EN 00-0: ; EN 00-5: 0 CSA Certificate: 5 Class I, Division, Groups A, B, C D; T* CAN/ CSA C. No. 0-M; CAN/ CSA C. No. -M; CAN/ CSA C. No 00.-; CAN/ CSA C. No 00.B-; CSA C. No. -M FM Certificate: 0 Class, Div. Groups A, B, C, D; T* FM 00: 0; FM : 0; FM 0: 05 * Module Temperature: Classifications T to T Cables High voltage Low voltage I/O module Compliance CE Conformity Lengths:.0,.5, 5.0 meters. Cable power is limited to Amps per module at 0C (0 degrees F) and Amps at 5C ( degrees F). Lengths:.0,.5, 5.0 meters. This product is in conformity with the protection requirements of the following European Council Directives: 0/ 5/ EC, the Low Voltage Directive (evaluated to EN00-:0) 0/0/EC, the EMC Directive (evaluated to EN-:). Conformity of this product with any other European Council Directive(s) shall not be assumed. General Purpose Safety Compliant with EN00-, UL00- nd Edition, CSA C. No. 00- Hazardous (Classified) Location Safety Controller (C0, C50, C0, C5) Module Type FM Class, Div., Groups A, B, C, D Class, Zone, IIC Safety Module Controller (C0S, C50S, C0S and C5S) Power Supply (P0, P) Power Status (PSM)) Scanner ( or Port) Safety Scanner ( or Port) Redundant Switch (RSM) Analog Input (Universal channel) Analog Input (High Level channel) Analog Output ( Channel) Analog Output ( channel) Analog Output ( channel) Digital Input, Contact type ( Channel) Digital Input, Vdc ( channel) Digital Input, /0 Vac ( channel) Temperature Classification T T T T T T T T T T T TC T5 T TC@ Ta = 0 deg. C Ta = 0 deg. C

4 ControlEdge 00 Platform Modules Digital Input, /0 Vac ( channel 5 Vdc) Digital Input Vdc ( channel) Digital Output, Relay type ( channel) Digital Output, Vdc, ( channel) Digital Output, /0 Vac ( channel) Digital Output Vdc ( channel) Pulse/Frequency/Quadrature ( channel) Universal IO Module ( channel) TC@ Ta = 0 deg. C Ta = 0 deg. C TC@ Ta = 0 deg. C Ta = 0 deg. C T5 T T T T5 T Power Supply P0 Power Supply (00P0-xxxx) The P0 power supply provides 5VDC and VDC to satisfy the power requirements of a rack with a controller and local I/O, a rack with a scanner, and remote I/O. The 0-watt capacity allows for almost any mix of I/O modules in one rack. See Module Specifications starting on page. A tool-secured door covers the high voltage connections; test jacks behind the door allow for quick verification of proper operation. An internal non-replaceable fuse limits supply current under certain fault conditions. P Power Supply (00P-xxxx) The P power supply provides 5VDC and VDC to satisfy the power requirements of a rack with a controller and local I/O, a rack with a scanner and remote I/O or a redundant controller rack. The 0-watt capacity requires minimal de-rating of the available ControlEdge HC00 I/O modules. A toolsecured door covers the voltage connections. An internal non-replaceable fuse limits supply current under certain fault conditions. Wiring Operating Voltage P0 Power Supply (00P0- xxxx) Screw type terminals, Wire gauge #- AWG Universal Power, 0-VAC, - Hz P Power Supply (00P-xxxx) Screw type terminals, Wire gauge #- AWG -VDC Input Rating 0VA.5W Output Rating 0W 0W In Rush Current Amps peak-to-peak for 50 ms at 0 VAC In-rush current: 0A for Fuse Internal, non-replaceable Internal, non-replaceable Test jacks 5 volt, Volt None Hold up time 5VAC, 0HZ maximum Load See next section for how to choose an AC power supply.

5 ControlEdge 00 Platform Modules 5 How to choose an AC Power Supply Module type SIL CPU A B C D E Enter Quantity Max 5 V Max V Calculate 5V current ( D = A * B) Calculate V current ( E = A * C) Controller C0S CPU ( ) ma 0 ma ( ) ( 0 ) Controller C50S CPUL ( ) 0 ma 0 ma ( ) ( 0 ) Controller C0S CPU ( ) 50 ma 0 ma ( ) ( 0 ) Controller C5S ( ) 500 ma 0 ma ( ) ( 0 ) I/O Scanner Port ( per I/O rack) - SIL ( ) I/O Scanner Port ( per I/O rack) - SIL ( ) Non-SIL CPU 0 ma 0 ma 0 ma 0 ma ( ) ( 0 ) ( ) ( 0 ) Controller C0 CPU ( ) ma 0 ma ( ) ( 0 ) Controller C50 CPU ( ) 0 ma 0 ma ( ) ( 0 ) Controller C0 CPU ( ) 50 ma 0 ma ( ) ( 0 ) Controller C0R CPU ( ) 500 ma 0 ma ( ) ( 0 ) I/O Scanner Port ( per I/O rack) ( ) I/O Scanner Port ( per I/O rack) ( ) 0 ma 0 ma 0 ma 0 ma ( ) ( 0 ) ( ) ( 0 ) Power Status Module (PSM) ( ) ma 0 ma ( ) ( 0 ) Analog Input ( pts) ( ) 0 ma 5 ma ( ) ( ) Analog Input ( pts) ( ) 5 ma 50 ma ( ) ( ) Analog Output ( pts) * ( ) 0 ma 0 ma ( ) ( ) Analog Output ( pts) *** ( ) 5 ma 50 ma ( ) ( ) Analog Output ( pts) *** ( ) 50 ma 00 ma ( ) ( ) AC Digital Input ( pts) ( ) 0 ma 0 ma ( ) ( 0 ) DC Digital Input ( pts) ( ) 0 ma 0 ma ( ) ( 0 ) AC/DC Digital Input ( pts) ( ) 0 ma 0 ma ( ) ( 0 ) Contact Input ( pts) ( ) 0 ma 0 ma ( ) ( ) DC Digital Input ( pts) ( ) 5 ma 0 ma ( ) ( 0 ) AC Digital Output ( pts) ( ) ma 0 ma ( ) ( 0 ) DC Digital Output ( pts) ( ) 0 ma 0 ma ( ) ( 0 ) DC Digital Output ( pts) ( ) 5 ma 0 ma ( ) ( 0 ) Relay Output ( pts) ( ) 0 ma 00 ma ( ) ( ) Pulse/Frequency/Quadrature** ( ) 0 ma 50 ma ( ) ( ) Universal IO Module ( pts) ( ) 0 ma 00 ma ( ) ( )

6 ControlEdge 00 Platform Modules *Limit 0 Analog Output modules per I/O rack. ** Limit PFQ modules per I/O rack. *** Limit -pt. modules per rack. Limit 5 -pt. modules per rack with internal power supply. Use 0 ma for V value when using an external V supply. Total 5V = ( ) Total V= ( ) Complete columns A, D and E above.. Is column D total 5V less than 00mA? Yes/No. Is column E total V less than 00mA? Yes/No. If the answers to and are YES, go to. If the answer to or is NO, use power supply 00P Multiply 5V total by 5.. ( ) 5. Multiply V total by.5. ( ). Sum results of and 5. ( ). Divide results of by 000 ( ). Is the result of less than? Yes/No If the answer to is Yes, use power supply 00P0-000 If the answer to is No, use power supply 00P0-000 Analog Input Module (00A0-xxxx) The Universal Analog Input module supports up to user-configurable inputs on a per point basis for thermocouple, RTD, Resistance, V, mv, ma or slidewire. Point-to-point isolation and back-plane isolation are provided. Modules perform analog to digital conversion in synchronization with CPU control execution, eliminating data interchange latency. All analog input modules are processed in parallel, eliminating scan time increases as modules are added. A green blinking status LED on the module indicates when the module is being scanned. An amber blinking status LED when input channels are forced and a red status LED when module diagnostics exist. A user-selectable failsafe value is supported on a per channel basis. A warning signal is provided for thermocouple inputs to indicate maintenance is needed prior to a sensor failure. A sensor failure signal is also provided. Table - Analog Input Specifications Inputs per module Input types Signal Source (isolated) mv, V, T/C, RTD, ohms, ma, slidewire assigned to any channel See Table on page for range types. Thermocouple with cold junction compensation RTD, PT00 wire, 0 ohms balanced maximum Thermocouples: 00 Ohms/Leg 00 (except Low), 500 & 000 RTD: 00 Ohms/Leg

7 ControlEdge 00 Platform Modules Table - Analog Input Specifications Input Impedance Galvanic Input Isolation Noise Rejection Burnout Over-range limit T/C Break Detection Faulty thermocouple detection Accuracy Temp. Effect on Accuracy A/D Converter A/D Resolution Reference Junction Sensing Update rate Long term Stability Calibration Diagnostics Channel Configuration Data Power supply loading 00 YIS: 00 Ohms/Leg 00-Low RTD & 0 ohm Cu: 0 Ohms/Leg Slidewire 00 to,500 Ohms: 0% of total res./leg 0 megohms for T/C and mv inputs; > megohm for volts and 50 ohms for ma inputs 00 VDC point to point, K VDC to logic RTDs are isolated in pairs (IRTD is common to two inputs). Series Mode >0dB. Common Mode >0dB at VAC. T/C, mv, V (except for ranges below) configurable to upscale, downscale, defined value, or none. Volt: 500 mv to 500 mv; V to V; V to V; 5 V to 5 V; 0 V to 0 V; 0 V to 0 V; inherent to zero volt RTD: Inherent upscale ma: Inherent downscale +/- 0% for linear ranges (volts). +/-% for non-linear ranges (T/C, RTD). Via current pulse If greater than 00 ohms, a warning status is provided as an output for the AI block Factory configured accuracy = ± 0. % of range (± 0. % of range for 0V to 0V and -0V to 0V) Cold junction accuracy = ± 0. C Field calibration accuracy = ± 0.05 % of range Reference conditions: Temperature = 5 C ± C ( F ± 5 F) Humidity = 5 % to 55 % RH non-condensing Line voltage = Nominal ± % Source resistance = 0 ohm Series mode and common mode = 0 V Frequency = Nominal ± % 0.0% of full scale per degree Celsius maximum One per module 5 Bits Via RTDs at top/bottom of module 500ms (Analog to Digital Converter per module) 0.% per year Data is stored in non-volatile memory Redundant Factory Calibration Individual Channel Field Calibration Monitoring of Factory Calibration, Field Calibration, VDC supply, and configuration. Stored in non-volatile memory 5V; 0mA max V; 5mA max

8 ControlEdge 00 Platform Modules Table Analog Input Reference Accuracy Input Type Range Reference Accuracy Thermocouple inputs F C F C B T/C 0 to 05 - to NA NA 05 to 50 to to 500 to to to to 00 5 to 5.0. E T/C -5 to - -0 to to -0 to E (low) T/C -0 to 00 - to 5.0. J T/C 0 to 00 - to. 0. J (low) T/C to 0 - to J T/C - to -0 to K T/C 0 to 00 - to.0. K (low) T/C - to to K T/C (mid)** 0 to 00 - to..0 K T/C to 0 to 0.0. Ni-NiMo (NNM) to to to to.5 0. Ni-NiMo (low) to 0 0 to. 0. NiMo-NiCo (NM0) to to to to.5 0. NiMo-NiCo (low) to 0 0 to. 0. N T/C 0 to - to N T/C 0 to - to N T/C to 0 to 0.0. R T/C 0 to to to 00 0 to 0.. S T/C 0 to to to 00 0 to 0.. T T/C -00 to 00 - to to 00 - to.0. T (low) T/C -0 to to W_ W - to to to 0 - to to to.0.0. W5 W T/C * 0 to 00 - to to 00 to to 0 to.5.0 W5 W (low) T/C* 0 to 0 - to.5. * W5W is also known as type C Thermocouple. ** Type K thermocouple (mid-range) has a working range from 5 to 00 F, 5 to C. Input measurements below 5 F or 5 C may cause the input to default to the programmed failsafe value. Use type K low or full ranges if measurements are required outside the mid- working range

9 ControlEdge 00 Platform Modules RTD F C F C Platinel - to -0 to Platinel (low) to 5 0 to Pt. (high) RTD*** 00 to 500 to Pt. (mid) RTD*** -00 to 0 - to Pt. (low) RTD*** -00 to 00 - to Pt. RTD*** -00 to 0 - to Pt RTD***** -0 to to JIS - to -0 to JIS (low) 0 to - to Cu0 - to - to YSI05 50 to 00 0 to Input Type Range Reference Accuracy Ohms, 0 0 to 0 +/- 0. ohms Ohms, to 500 +/-.0 ohms Ohms, to 000 +/-.0 ohms Ohms, 00 0 to 00 +/-.0 ohms Ohms, to 000 +/-.0 ohms Milliamperes to madc 0.% F.S. (ma)**** 0 to madc 0.% F.S. (ma)**** Millivolts 0 to 0 mvdc 0.% F.S. (mv) 0 to 50 mvdc 0.% F.S. (mv) 0 to 00 mvdc 0.% F.S. (mv) -0 to 0 mvdc 0.% F.S. (mv) -50 to 50 mvdc 0.% F.S. (mv) -00 to 00 mvdc 0.% F.S. (mv) -500 to 500 mvdc 0.% F.S. (mv) Volts to 5 VDC 0.% F.S. (mv) Slidewire 0 to VDC 0.% F.S. (mv) 0 to VDC 0.% F.S. (mv) 0 to 5 VDC 0.% F.S. (mv) 0 to 0 VDC 0.% F.S. (mv) - to VDC 0.% F.S. (mv) - to VDC 0.% F.S. (mv) -5 to 5 VDC 0.% F.S. (mv) -0 to 0 VDC 0.% F.S. (mv) 50 ohms 50 to 50 ohms 50 to 000 ohms 000 to 500 ohms Carbon 0 to 50 mvdc 0.% F.S. (mv) Oxygen -0 to 50 mvdc 0.% F.S. (mv) *** Conforms to IEC5 **** Tolerances for these input types include that of the external Dropping Resistors. ***** Ohm/Ohm/ DegC Calibration standards are based on ITS-0; except Ni-NiMo is based on IPTS-.

10 0 ControlEdge 00 Platform Modules High Level Analog Input Module (00A-xxxx) The High-Level Analog Input module supports up to user-configurable inputs on a per point basis for Voltage or current. Point-to-point isolation and back-plane isolation are provided. Modules perform analog to digital conversion in synchronization with CPU control execution, eliminating data interchange latency. All analog input modules are processed in parallel, eliminating scan time increases as modules are added. A green blinking status LED on the module indicates when the module is being scanned. An amber blinking status LED when input channels are forced and a red status LED when module diagnostics exist. A userselectable failsafe value is supported on a per channel basis. The module supports field calibration. Each of the inputs has its own integrated 50-ohm shunt resistor which is activated through DIP switches. Requires Euro style -terminal terminal block. In + In + In - In - In + In + In - In - In 5+ In + In 5- In - In + In + In - In - In + In 0+ In - In 0- In + In + In - In - In + In + In - In - In 5+ In + In 5- In - NC NC NC NC Table High Level Analog Input Specifications Inputs per module Input types Signal Source Input Impedance Galvanic Input Isolation Noise Rejection Over-range limit (isolated) V, ma See Table on next page for range types. > megohm for volts and 50 ohms for ma inputs 00 VDC point to point, solid state switching; K VDC to logic. Series Mode >db Common Mode >0dB at VAC +/- 0% for linear ranges (volts).

11 ControlEdge 00 Platform Modules Table High Level Analog Input Specifications Accuracy Temp. Effect on Accuracy A/D Converter A/D Resolution Update rate Long term Stability Calibration Diagnostics Channel Configuration Data Power supply loading Factory configured accuracy = ± 0. % of range. Field calibration accuracy = ± 0.05 % of range Reference conditions Temperature = 5 C ± C ( F ± 5 F) Humidity = 5 % to 55 % RH non-condensing Line voltage = Nominal ± % Source resistance = 0 ohm Series mode and common mode = 0 V Frequency = Nominal ± % ±0.0% of full scale per degree Celsius maximum One per module 5 Bits 00ms (Analog to Digital Converter per module) 0.% per year Data is stored in non-volatile memory Redundant Factory Calibration Individual Channel Field Calibration Monitoring of Factory Calibration, Field Calibration, VDC supply, and configuration. Stored in non-volatile memory. 5V ; 5mA max V ; 50mA max Table - High Level Analog Input Reference Accuracy Input Type Range Reference Accuracy Milliamperes to madc 0.5% F.S. (ma)** 0 to madc 0.5% F.S. (ma)** ** Tolerances for these input types include that of the internal Dropping Resistors. Volts 0 to VDC 0.% F.S. (mv) 0 to VDC 0.% F.S. (mv) 0 to 5 VDC 0.% F.S. (mv) 0 to 0 VDC 0.% F.S. (mv) to 5 VDC 0.% F.S. (mv) - to VDC 0.% F.S. (mv) - to VDC 0.% F.S. (mv) -5 to 5 VDC 0.% F.S. (mv) -0 to 0 VDC 0.% F.S. (mv)

12 ControlEdge 00 Platform Modules Analog Output Module (00B0-xxxx) The Analog Output module provides isolated 0 to. ma outputs that may be scaled by the user to any span within this range on a per output basis. A green blinking status LED on the module indicates when the module is being scanned. A red status LED when module or channel diagnostics exist. A user specified failsafe value is supported to allow predictable operation in the event communication between the module and the controller is interrupted. Outputs are updated synchronous with control execution. A user specified rate of change limit may be applied to each output when needed. Out + Out - Out + Out - Out + Out - Out + Out Outputs per module Current Load resistance Galvanic Isolation Galvanic Isolation from logic Accuracy Modules per rack Minimum current sensing Calibration Data Diagnostics Output Verification D/A Resolution Power Supply Loading (isolated) 0 to. ma, range selectable 50 ohms max 500VDC Channel to Channel. 00 VDC 0.% full scale at reference conditions 0 max, up to with product ambient temperature de-rating (see figure below) >.5 ma per output Data is stored in non-volatile memory. Redundant Factory Calibration, with automatic rejection of Bad version. Individual Channel Field Calibration Monitoring of Factory Calibration, Field Calibration, Configuration, and + VDC power supply. Feedback to controller that indicates output current flowing. bits 5V ; 0mA max V ; 0mA max P0 Power Supply De-rating for AO Modules

13 ControlEdge 00 Platform Modules Analog Output Module (00B0-xxxx) The Analog Output module provides eight 0 to.0 ma outputs that may be scaled by the user to any span within this range on a per output basis. Outputs are isolated in groups of with no isolation between outputs in a group. All points are isolated from controller logic. A green blinking status LED on the module indicates when the module is being scanned. A red status LED when module or channel diagnostics exist. A user specified failsafe value is supported to allow predictable operation in the event communication between the module and the controller is interrupted. Outputs are updated synchronous with control execution. A user-specified rate of change limit may be applied to each output when needed. Requires Euro style -terminal terminal block. Outputs per module, isolated in groups of outputs (-, 5-) Current Load resistance 0 to.0 ma, range selectable 50 ohms max Galvanic Isolation 500VDC group to group. Groups -, 5- Galvanic Isolation from logic Accuracy Modules per rack Minimum current sensing Calibration Data Diagnostics Output Verification 500 VDC 0.% full scale at reference conditions max when powered from internal V backplane power >0.5mA per output Data is stored in non-volatile memory. Redundant Factory Calibration, with automatic rejection of Bad version. Individual Channel Field Calibration Monitoring of Factory Calibration, Field Calibration, Configuration Feedback to controller to indicate output current is flowing. D/A Resolution + bits ( part in ) Power Supply Loading 5V ; 5 ma max V ; 50 ma max Terminal Block Position Euro style, (Model 00TCK- 000) A DIP switch on the module selects the use of V from Rack PS (internal) power or external loop power via a separate V DC power source. The as-shipped (default) switch setting is external power. External Power Source requirements: Voltage Vin: to Vdc Current 50 ma per module

14 ControlEdge 00 Platform Modules Analog Output Module (00B-xxxx) The Analog Output module provides, 0 to.0 ma outputs that may be scaled by the user to any span within this range on a per output basis. Outputs are isolated in groups of with no isolation between outputs in a group. All points are isolated from controller logic. A green blinking status LED on the module indicates when the module is being scanned. A red status LED when module or channel diagnostic exist. A user specified failsafe value is supported to allow predictable operation in the event communication between the module and the controller is interrupted. Outputs are updated synchronous with control execution. A user-specified rate of change limit may be applied to each output when needed. Requires Euro style - terminal terminal block. Outputs per module, isolated in groups of outputs (-, 5-, -, -) Current Load resistance 0 to.0 ma, range selectable 50 ohms max Galvanic Isolation 500VDC group to group. Groups -, 5-, -, -. Galvanic Isolation from logic Accuracy Modules per rack Minimum current sensing Calibration Data Diagnostics Output Verification 500 VDC 0.% full scale at reference conditions max when powered from internal V backplane power. > 0.5mA per output Data is stored in non-volatile memory. Redundant Factory Calibration, with automatic rejection of Bad version. Individual Channel Field Calibration Monitoring of Factory Calibration, Field Calibration, and Configuration. Feedback to controller to indicate output current is flowing. D/A Resolution + bits ( part in ) Power Supply Loading 5V ; 50 ma max V ; 00 ma max OUT + OUT + OUT - OUT - OUT + OUT + OUT - OUT - OUT 5+ OUT + OUT 5- OUT - OUT + OUT + OUT - OUT - OUT + OUT 0+ OUT - OUT 0- OUT + OUT + OUT - OUT - OUT + OUT + OUT - OUT - OUT 5+ OUT + OUT 5- OUT - NC NC VDC+ VDC Terminal Block Position Euro style, (Model 00TCK-000) A DIP switch on the module selects the use of V from rack PS (internal) power or external loop power via a separate V DC power source. The as-shipped (default) switch setting is external power. External Power Source requirements: Voltage to Vdc Current 00 ma per module

15 ControlEdge 00 Platform Modules 5 Digital Input Module Contact Closure Type (00G0- xxxx) The Contact Closure Digital Input Module is self-powered, providing 5VDC to external switching hardware to close the input loop. A closed external circuit causes current flow to the input to establish an ON state. Logic in the controller allows this state to be inverted when necessary. Four common terminals are provided to simplify field wiring. There is a green LED state indicator for each channel to indicate when a digital input is ON. A green blinking status LED on the module indicates when the module is being scanned. An amber blinking status LED indicates when channels are forced and a red status LED when module diagnostics exist. In In In In In 5 In In In COM COM COM COM In In 0 In In In In In5 In Inputs per module Voltage Supplied by controller Maximum contact resistance Galvanic Isolation OFF to ON response time* ON to OFF response time* Switching current Power supply loading (single-ended) 5 VDC nominal 000 ohms Isolation - Between Field wiring (input or output) and Module (Microcontroller or Backplane). ms max ms max. ma nominal 5V ; 0 ma max V ; 0 ma max *excluding controllers scan time and excluding transmission time from module to backplane

16 ControlEdge 00 Platform Modules Digital Input Module - DC Voltage type (00G0-xxxx) The DC Digital Input module provides two groups of inputs, each with a pair of terminals for connection to common. DC power applied between the common terminal and an input cause the input to turn ON. There is a green LED state indicator for each channel on the module to indicate when a digital input is ON. A green blinking status LED on the module indicates when the module is being scanned. An amber blinking status LED indicates when channels are forced and a red status LED when module diagnostics exist. Logic in the controller allows the state to be inverted when necessary. In In In In In 5 In In In - COM - COM - COM - COM In In 0 In In In In In5 In Inputs per module Input Voltage Range Peak Voltage AC Frequency Galvanic Isolation ON Voltage Level OFF Voltage Level Input Impedance Input Current Minimum ON Current Maximum OFF Current OFF to ON response time* ON to OFF response time* Power Supply Loading (sinking) 0 VDC to VDC VDC N/A groups of inputs (.VDC max.).5 VDC minimum.5 VDC maximum. K ohms nominal. VDC. VDC nominal.0 ma 0. ma ms max ms max 5V; 0mA max V; 0mA *excluding controllers scan time and excluding transmission time from module to backplane

17 ControlEdge 00 Platform Modules Digital Input Module AC Voltage type (00G0-xxxx) The AC Digital Input modules are externally powered and accommodate two circuit voltages for up to inputs each. Two common terminals are provided for each circuit. AC power applied between the common terminal and an input cause the input to turn ON. There is a green LED state indicator for each channel on the module to indicate when a digital input is ON. Logic in the controller allows the state to be inverted when necessary. A green blinking status LED on the module indicates when the module is being scanned. An amber blinking status LED indicates when channels are forced and a red status LED when module diagnostics exist. Inputs per module Input Voltage Range Peak Voltage AC Frequency Galvanic Isolation ON Voltage Level OFF Voltage Level Input Impedance Input Current Minimum ON Current Maximum OFF Current OFF to ON response time* ON to OFF response time* Power Supply Loading (sinking) 0 VAC to VAC VAC Hz to Hz groups of inputs (50VAC max.) 5 VAC VAC K ohms nominal ma VAC, 0 Hz ma 0 VAC, 50 Hz 0. ma 0. ma ms +.5 line cycles maximum ms + line cycles maximum 5V; 0mA max V; 0mA Active input De-rating table for ACDI In + In + In + In + In 5+ 5 In + In + In + - COM - COM 0 - COM - COM In + In 0+ In + 5 In + In + In + In5+ In +

18 ControlEdge 00 Platform Modules Digital Input Module AC DC Voltage type (00G0-xxsx) The AC/DC Input Module provides sixteen individually isolated, inputs that are powered externally. Two terminals are provided for each circuit. AC or DC power applied between the input terminals cause the inputs to turn On. There is a green LED state indicator for each channel on the module to indicate when a digital input is ON. A green blinking status LED on the module indicates when the module is being scanned. An amber blinking status LED indicates when channels are forced and a red status LED when module diagnostics exist.. Logic in the controller allows the state to be inverted when necessary. Requires Euro style -terminal terminal block. Parameter AC Application DC Application Inputs per Module Input Voltage Range 0 VAC to VAC 0 VDC to 5 VDC Peak Voltage VAC 50 VDC AC Frequency Hz to Hz NA Galvanic Isolation Input to Input & Input to Chassis (50VAC max) On Voltage Level 5 VAC 5 VDC Off Voltage Level VAC 0 VDC Input to Input & Input to Chassis (50VAC max) Input Impedance k ohms nominal k ohms nominal Input Current ma VAC, 0 Hz ma 50 Hz Minimum On Current 0. ma 0. ma Maximum Off Current Off to On response time* On to Off response time* Power Supply Loading 0. ma 0. ma ma VDC ms +.5 line cycles max. ms + line cycles max. ms + line cycles max. ms + line cycles max. 5 V, 0 ma max. V 0 ma. 5 V, 0 ma max. V 0 ma. * Nominal times excluding controllers scan time and excluding transmission time from module to backplane. DC application must include controller line filter setting of 50/0 Hz Active input De-rating table for AC/DC DI

19 ControlEdge 00 Platform Modules Point Digital Input Module - DC Voltage type (00G-xxxx) The DC Digital Input module provides inputs separated in to groups of channels each. Each group has a pair of screw terminals for the COM connection. DC power applied between the common terminal and an input cause the input to turn ON. There is a green LED state indicator for each channel on the module to indicate when a digital input is ON. A green blinking status LED on the module indicates when the module is being scanned. An amber blinking status LED indicates when channels are forced and a red status LED when module diagnostics exist. Logic in the controller allows the state to be inverted when necessary. Requires Euro style -terminal terminal block Inputs per module Input Voltage Range Peak Voltage AC Frequency Galvanic Isolation ON Voltage Level OFF Voltage Level Input Impedance (sinking) 0 VDC to VDC VDC N/A groups of inputs (0VDC max.).5 VDC minimum.5 VDC maximum. K ohms nominal Input Current. VDC.5 VDC nominal Minimum ON Current Maximum OFF Current OFF to ON response time* ON to OFF response time* Power Supply Loading.0 ma 0. ma 5 ms max 5 ms max 5V; 5mA max V; 0mA *excluding controllers scan time and excluding transmission time from module to backplane In + In + In + In + In 5+ In + In + In + In + In 0+ In + In + In + In + In 5+ In + -COM -COM In + In + In + In + In + In + In + In + In 5+ In + In + In + In + In 0+ In + In + -COM -COM

20 ControlEdge 00 Platform Modules Relay Output Module (00H0-xxxx) The Relay Output Module provides eight individual galvanically isolated, electromechanical relay outputs. Four of the outputs are Form-C, and the other four are Form-A. Outputs are not fused in the Relay module. Install a fuse for each output at the field device that is appropriate for the load and the wire used. There is a green LED state indicator for each channel on the module to indicate when a digital output is ON. A green blinking status LED on the module indicates when the module is being scanned. An amber blinking status LED indicates when channels are forced and a red status LED when module diagnostics exist. Relays per module form A, form C Output Device Voltage Current Rating Galvanic Isolation Max. Leakage Current De-rating OFF to ON response time* ON to OFF response time* Power Supply Loading Expected life (min. operations) Electromechanical relay /0 VAC, 0 VDC 0VAC or 0VDC resistive load 0.5 0VAC or 0VDC incandescent lamp load Relay Output Contact to Relay Output Contact Relay Output Contact to Logic 50 VDC Max. outputs at max. load none Max. modules per rack - none ms max ms max 5V; 0mA max V; 00mA max Mechanical at 0 cpm: 5 x 0E Electrical: 0E5 *excluding controllers scan time and excluding transmission time from module to backplane Life expectancy curves (ab type)

21 ControlEdge 00 Platform Modules Digital Output Module DC Type (00H0-xxxx) The DC Digital Output module provides outputs separated in to groups of channels each that are powered externally. Each group has a pair of screw terminals for +V and COM connections. The outputs are low side switching (current sinking) type. Overload protection is built into each output; when tripped the power must be recycled to reset the module. There is a green LED state indicator for each channel on the module to indicate when a digital output is ON. A green blinking status LED on the module indicates when the module is being scanned. An amber blinking status LED indicates when channels are forced and a red status LED when module diagnostics exist.. Outputs per module Galvanic Isolation (current sinking, low side) groups of outputs Out + Out + Out + Out + Out 5+ Out + Out + Out + + V - COM + V - COM Out + Out 0+ Out + Out + Out + Out + Out5+ Out Operating Voltage.5 to VDC (5.0 to.5 <0.5A per channel) Output Type Intelligent power switch (IPS) Peak Voltage VDC AC Frequency N/A ON Voltage Drop I A load Overload Protection Electronic high current and high temperature limiting, resets after cycling field power Maximum Load Current A per point, A max. per module, resistive load 0.5 A per point incandescent lamp load (5 mh max) Maximum Leakage Current VDC Maximum Inrush Current A for 0 ms Minimum Load 0.0 ma OFF to ON response time* ms ON to OFF response time* ms Fuses Electronic limiting Power Supply Loading 5V; 0mA V; 0mA *excluding controllers scan time and excluding transmission time from module to backplane

22 ControlEdge 00 Platform Modules Digital Output AC Type (00H0-xxxx) The AC Digital Output module provides isolated zero switching Triac solid-state outputs. A shorting comb is available for use with barrier type terminal blocks to simplify connections to a common voltage source for all outputs. Each output has a MOV for transient overvoltage protection and a field-replaceable fuse. There is a green LED state indicator for each channel on the module to indicate when a digital output is ON. A green blinking status LED on the module indicates when the module is being scanned. An amber blinking status LED indicates when channels are forced and a red status LED when module diagnostics exist.. Out H Out NO Out H Out NO Out H Out NO Out H Out NO Out 5 H Out 5 NO Out H Out NO Out H Out NO Out H Out NO Outputs per Module Galvanic Isolation Operating Voltage Output Type Peak Voltage AC Frequency Per output to output, output to logic 5 VAC to 0 VAC Triac (zero switching voltage) 50 VAC Hz to Hz ON Voltage Drop <.0 VAC (>0. A) <.0 VAC (<0. A) Transient Over voltage Protection Maximum Load Current Maximum Leakage Current Maximum Inrush Current Minimum Load OFF to ON response time* ON to OFF response time* Fuses Power Supply Loading MOV A per point, A max. per module, resistive load ma (0 VAC, 0 Hz). ma (00 VAC, 0 Hz) 0. ma (00 VAC, 50 Hz) 5 A for 0 ms 50 ma ms line cycle max ms line cycle max per output,.5 A Time-lag. Replacement part: Littelfuse 500 5V; ma max V; 0mA *excluding controllers scan time and excluding transmission time from module to backplane

23 ControlEdge 00 Platform Modules Point Digital Output Module DC Type (00H-xxxx) The DC digital Output module provides outputs separated in to groups of channels each that are powered externally. Each group has a pair of screw terminals for +V and COM connections. The outputs are high side switching (current sourcing) type. Over current protection is provided for all outputs in groups of channels each. In case of short circuit for any output channel, that whole group of is switched off. Power cycling is not required to reset the module. There is a green LED state indicator for each channel on the module to indicate when a digital output is ON. Maximum Leakage Current Maximum Inrush Current Minimum Load OFF to ON response time* ON to OFF response time* Fuses VDC A for 0 ms 0.0 ma ms ms Electronic limiting A green blinking status LED on the module indicates when the module is being scanned. An amber blinking status LED indicates when channels are forced and a red status LED when module diagnostics exist. Requires Euro style -terminal terminal block. Power Supply Loading 5V; 5mA V; 0mA *excluding controllers scan time and excluding transmission time from module to backplane Outputs per module (current sourcing, high side). Galvanic Isolation Operating Voltage Output Type Peak Voltage AC Frequency ON Voltage Drop Overload Protection Maximum Load Current Note: Outputs through may not be used for TPO (Time Proportioning Output), PPO (Position Proportioning Output) or TPSC (Three Position Step Output) output types. groups of outputs 0.5 to VDC High side driver VDC N/A A load Active Current Limiting is integrated into the output driver as groups of channels each. Power cycling is not required to reset the module after a fault condition. 0.5 A per point, A max per channel group A max. per module, resistive load Out + Out + Out + Out + Out 5+ Out + Out + Out + Out + Out 0+ Out + Out + Out + Out + Out 5+ Out + +V COM Out + Out + Out + Out + Out + Out + Out + Out + Out 5+ Out + Out + Out + Out + Out 0+ Out + Out + +V COM A per point incandescent lamp load (5 mh max)

24 ControlEdge 00 Platform Modules Channel Pulse/Frequency/Quadrature Module - DC Voltage type (00K0-xxxx) In + In - In + In - In + In - In + In - INDEX+ INDEX- SENSE+ SENSE- OUTPUT OUTPUT OUTPUT OUTPUT COM ENCODE+ ENCODE The Channel Pulse/Frequency/Quadrature Module provides four different functionalities in the form of Pulse Input, Frequency measurement, Quadrature encoder input and Pulse Output. Each of these channels can be configured for any one of these four functions; with the exception that quadrature encoder input (A and B pulses) can be applied to only Channels and respectively. When configured for quadrature, the other two channels will still be available for use. The Pulse Output functionality uses the digital output available on the module for outputting pulses. A green blinking status LED on the module indicates when the module is being scanned. An amber blinking status LED indicates when channels are forced and a red status LED when module diagnostics exist. Note: For Quadrature input Differential mode, connect wires using reverse polarity (+ to -) on Input, Input and Index. Input Voltage Range Inputs per module Outputs per module Digital Output type Power Supply Loading 0 VDC to VDC Open collector, 5 to V, 0mA max, used for fast signaling 5V; 0mA max V; 50mA max (with Encoder) V; 00mA max (without Encoder) Pulse Input Specifications Input Voltage Range ON Voltage Level OFF Voltage Level Input Impedance Frequency Minimum Pulse Width Pulse Counter Preset Value Preset Action Digital Output Counting based on Preset Counter HOLD Counter RESET Counter Flags 0 VDC to VDC.0 VDC minimum.0 VDC maximum 5K ohm 0 KHz maximum µsec bits User may configure a preset count value within the range of bit counter Settable as ON or OFF in HC Designer If preset action ON, output turns ON for second. If preset action OFF, output latches ON, and remains ON until counter reset command. When the count equals preset value: If preset action ON, counter is reset and immediately resumes count. If preset action OFF, counter is not reset and counts beyond preset value. When the HOLD input to the pulse input function block is ON in HC Designer, the counter holds its current value. The counter may be reset only via its function block in HC Designer, when an OFF to ON transition occurs on the ^RST input in Monitor mode. The OVERFLOW flag gets set when the module counter overflows. This flag can be reset only with the ^CLFG command sent through HC Designer. Also, the PREI flag is set when the digital output of the module turns ON.

25 ControlEdge 00 Platform Modules 5 Channel Pulse/Frequency/Quadrature Module - DC Voltage type (00K0-xxxx) (cont d) Frequency Input Specifications Input Voltage Range ON Voltage Level OFF Voltage Level Input Impedance Frequency Minimum Pulse width (frequency ranges) Digital Output 0 VDC to VDC.0 VDC minimum.0 VDC maximum 5K ohm 0 Hz minimum 00 KHz maximum Settable only through HC Designer: 500 µsec (0 Hz to 500 Hz) 50 µsec (0 Hz to 5 KHz).5 µsec (0 Hz to 00 KHz) ON if input frequency out of range, else OFF Quadrature Input Specifications Channels Used Input Voltage Range ON Voltage Level OFF Voltage Level Common Mode Voltage Input Sensitivity Hysteresis Only channels and can be used for quadrature pulses A and B respectively. Index pulse is provided in addition. Differential: - VDC to + VDC Single-ended: 0 VDC to VDC Differential: 0. VDC minimum Single-ended:.0 VDC minimum Differential: -0. VDC maximum Single-ended: VDC maximum +/- VDC +/- 0mV +/- 50mV Module powered encoder 5V DC, 0.50A Frequency Minimum Pulse Width Quadrature Counter Quadrature Modes Quadrature LEDs 0 KHz maximum.5 µsec bits signed For variable resolution there are three count modes for the Pulse/Quadrature input: X: rising edges of signal A are counted (increment); falling edges of signal A (decrement) X: rising & falling edges of signal A are counted X: rising & falling edges of signals A & B are counted Two LEDs indicate UP and DOWN direction of counting.

26 ControlEdge 00 Platform Modules Channel Pulse/Frequency/Quadrature Module - DC Voltage type (00K0-xxxx) (cont d) Pulse Output Specifications Channels Used Digital Output Type Frequency Range Any one of the channels can be used for Pulse Output. However, the use of a particular channel for outputting pulses will render the particular input channel unusable for either of pulse, frequency or quadrature input. Open Collector, 5 to V, 0 ma max 5 Hz 0 KHz Duty cycle Always 50% Pulse Output Duration Selectable CONTINUOUS or NUMBERED PULSES. Channels Used Digital Output Type Frequency Range Any one of the channels can be used for Pulse Output. However, the use of a particular channel for outputting pulses will render the particular input channel unusable for either of pulse, frequency or quadrature input. Open Collector, 5 to V, 0 ma max 5 Hz 0 KHz Duty cycle Always 50% Pulse Output Duration Selectable CONTINUOUS or NUMBERED PULSES.

27 ControlEdge 00 Platform Modules Safety Universal Input /Output Module (00U0-xxx) Safety Universal Input/ Output (UIO) provides universal channels. Each channel of the module can be soft configured as AI, AO, DI or DO. Features supported by UIO are : Channels soft configurable as AI, AO, DI or DO (All channel are sourcing type) SOE (Sequence of Events) with resolution of ms Simplified wiring for SIL- applications due to single module solution. Line Monitoring for all configurations. Short circuit protection for DO Per channel Safety Shutdown eliminates need for external master relay. A green blinking status LED on the module indicates when the module is being scanned. A red status LED when module or channel diagnostics exist. For channels configured as Digital input a closed external circuit causes current flow from UIO to establish an ON state. Logic in the controller allows this state to be inverted when necessary. Analog outputs can only be configured on channels to. The Analog Output provides to ma outputs that may be scaled by the user to any span within this range on a per output basis. Digital Outputs provide over current protection.. In case of short circuit for any output channel, that channel is switched off. Power cycling is not required to reset the module. For channels which are configured as output (AO/DO) a user specified failsafe value is supported to allow predictable operation in the event of a communication loss between controller and IO module. Requires pin-terminal terminal block. INOUT INOUT INOUT INOUT INOUT5 INOUT INOUT INOUT COMM +V COMM +V INOUT INOUT0 INOUT INOUT INOUT INOUT INOUT5 INOUT 0 5 Universal IO channel can be soft configured as AI, AO, DI or DO. Details of each IO type are listed in tables below. Item Specification Channels V Field Supply Voltage V DC(Typical), V DC(Min) V DC(Max) Load Max. Amps per module 500 ma per channel

28 ControlEdge 00 Platform Modules Detail Specifications Analog Input Parameter Input type Input Channels A/D Converter Resolution Input Range Crosstalk, dc to 0 Hz (channel-to-channel) Input Impedance Maximum Input Voltage (any input referenced to common, no damage) Hardware accuracy Transmitter Field Power Conditioning Input Filter Specification Current (,, or wire devices) Maximum per module (line monitored) Bit - ma 5dB 50 Ω nominal 0-0V 0.% of full-scale (.5 ± C) 0.% of full-scale (0 to +0 C) Current limited to ma First-order low-pass khz Detail Specifications Analog Output Parameter Specification Output Type - ma current loop Output Channels Maximum per module Accuracy Output Ripple Output Readback Accuracy Output Current Linearity Resolution Directly Settable Output Current Range Maximum Resistive Load Minimum Resistive Load Maximum Output Compliant Voltage ( V supply = VDC through VDC) Maximum Open Circuit Voltage Maximum Load capacitance (with line monitoring) Assignable as channels to <0.5% of Full Scale (5 o C) including linearity, entire operating temperature =< 5 mv peak-to-peak at power line frequency, across 50 Ohm load 0.% of full scale ± 0.% of Full Scale nominal Bit. ma to ma 50 Ohms 50 Ohms VDC VDC < uf

29 ControlEdge 00 Platform Modules Detail Specifications Digital Input with OWD Parameter Open Voltage Short Circuit Current Open Contact Closed Contact Specification V ma 5 kω > 0. W A 5 kω > 0.5 W B Short circuit detection I > ma +/-5 % Closed contact detection. ma < I < ma +/-5 % Open contact detection 0. ma <= I <=. ma +/-5 % Lead Breakage Detection I < 0. ma +/-5 % Input filter First-order low-pass khz Note A: At VDC, equates to.5 KΩ > R > KΩ (where R = total loop resistance) Note B: At VDC, equates to. KΩ > R > 0 KΩ Detail Specifications Digital Input without Open Wire Detection Parameter Specification Open Voltage VDC Closed contact detection Open contact detection I >. ma C I <. ma D Input filter First-order low-pass khz Note C: At VDC, equates to R <.5 KΩ (where R = total loop resistance) Note D: At VDC, equates to. KΩ > R > 0 KΩ Detail Specifications Digital Output Parameter Specification Output Channels Maximum per module (with line monitoring) Output Type Load Current On-State Voltage Off-State Voltage Off-State Leak Current Maximum Load Inductance Maximum Load Capacitance Lamp Load Inrush Current DO read back current Accuracy Solid state source, short circuit protected 0mA Minimum to 0.5 A Maximum per channel A Maximum per module V (typ), load 0.5 A 0 VDC (max) Open Load < 0. ma < 0 H < uf < Watt (Verify Inrush Current requirement of Lamp Load) A for 0 us DO Current : 0-0 ma +/- ma -00 ma +/- 5 ma ma +/- ma Note:. 00U0 modules may not be installed such that the 00U0 is between two 00B modules. 00B may only be installed in one adjacent slot.. Field power to be supplied by a local power supply providing tertiary protection from zone B severity levels. Generally characterized by short wiring, isolation, surge suppressors etc.. For Marine applications ABS Type approved power supplies are required for field supply voltage.. Field supply voltage should be maintained higher than.5 V for AO higher AO loads (> 50 Ohms)

30 0 ControlEdge 00 Platform Modules Terminal Blocks (00TEK-xxxx, 00TBK-xxxx, 00TER-xxxx, 00TBR-xxxx) ControlEdge HC00 I/O modules use terminal blocks with The rear of the Terminal block provides keying to prevent various features available. accidental terminal block insertion into incorrect module slots. Labels are provided to identify the module type by Terminals are available in Barrier style and Euro style. name and color, offer wiring instructions and provide an The Barrier style terminal block provides a floating area for customer identification of field circuits. Shorting washer to accommodate two different size conductors. combs are available for use with Barrier terminal blocks The Euro style offers a more compact terminal design to connect common signal pairs together or to jumper providing more room within the terminal block cavity for together common signals on AC and Relay output conductors. modules. All terminal blocks support customer wiring entering the block from the top or bottom when mounted in the controller. A locking swing out door provides easy access for wiring and covers potential high voltage connections during operation. Shield terminal strips are also available to terminate the shields of shielded cables at the controller. For low voltage terminals accepting thermocouple inputs, cold junction compensation is provided by the AI modules. Terminal blocks are secured to the rack assembly with screws. These screws provide vibration immune terminal connections during operation and also serve as jacking screws when removing modules to minimize the extraction force required. Sample terminal blocks (L) -terminal high voltage Barrier (R) -terminal Euro

31 ControlEdge 00 Platform Modules Number of terminals * Type Terminal blocks removable under instrument power. (Field power disconnected) Gauge Wires Barrier and Euro: # to AWG, solid or stranded Terminal color Contacts High voltage: Red Low Voltage: Black High Voltage: Tin Coated Low Voltage: Gold Plated Terminal blocks removable under instrument power. (Field power disconnected) Euro: # to AWG, solid or stranded Black Gold plated Contact Style Post and socket Post and socket Door Access Tool accessible Tool accessible Cold Junction compensation for thermocouples Yes (provided by AI module) N/A thermocouples not used *Required with the following I/O modules: HL AI, AO, AO, DI, DO and AC/DC DI. Terminal styles (top) Barrier (middle) Euro (bottom) -terminal Euro I/O Scanner Module (00S50x-xxxx) The I/O Scanner module resides in a remote I/O rack along with the I/O modules. The Scanner and the controller are connected to each other s I/O port (see the photo on the right side of this page). The scanner collects data from the Input modules populated in its remote rack and communicates the information to the controller. Output data is sent from the controller to the Scanner module which in turn sends the data to appropriate output module. Data exchanges are synchronous with the controller scan time to maintain deterministic operation. Diagnostic status of I/O modules is also monitored and reported to the controller when detected. The Rack address of a Scanner is set via DIP switches on the Scanner s circuit board. Connection to the controller uses IEEE 0. Ethernet 00base-TxPhysical Layer. An external Ethernet switch is required when multiple I/O scanners are used with a single controller. Scanner modules do support removal and insertion under power. Process Scanner (left) Safety Scanner (right) Type Status indicators Power supply loading I/O Scanner Scanner: Module status Red/Green LED indicates mode or error Expansion I/O port: Green and Yellow LEDs indicate receive/transmit 5V; 0 ma max

32 ControlEdge 00 Platform Modules I/O Scanner Module (00S5x-xxxx) The I/O Scanner module resides in a remote I/O rack along with its I/O in a Redundant Controller System. The Scanner has two I/O connections I/O A is connected to CPU-A and I/O B is connected to CPU-B in the Redundant Controller rack. The scanner collects data from the Input modules populated in its remote rack and communicates the information to the Lead controller. Output data is sent from the Lead controller to the Scanner module which in turn sends the data to appropriate output module. Data exchanges are synchronous with the controller scan time to maintain deterministic operation. Diagnostic status of I/O modules is also monitored and reported to the controller when detected. The Rack address of a Scanner module is set via switches on the module. Connection to both of the redundant controllers is made using both ports, each conforming uses IEEE 0. Ethernet 00base- TxPhysical Layer. An external Ethernet switch is required when multiple I/O scanners are used with a single controller. Scanner modules do support removal and insertion under power. Process Scanner (left) Safety Scanner (right) Type Status indicators Power supply loading I/O Scanner Scanner: Red/Green LED indicates mode or error I/O A Port: Green and Yellow LEDs indicate receive/transmit I/O A Port: Green and Yellow LEDs indicate receive/transmit 5V; 0mA max

33 ControlEdge 00 Platform Modules Redundant Switch Module (RSM) (00RSM-xxxx) The Redundant Switch Module resides in a ControlEdge HC00 Redundant controller rack and interfaces with both CPUs of a redundant system and indicates which CPU is functioning as the Lead controller and which is the Reserve. A key switch on the module sets the mode of both the Lead and Reserve controllers, guaranteeing synchronization of CPUs. A momentary contact position of the key switch allows the user to switch the Lead control function from CPU-A to CPU-B or vice versa. The RSM module supports insertion and removal under power. Type Lead/Reserve indication Mode Switch Power Supply Loading Redundant CPU Status and Mode control Module Green arrow LEDs Removable key ( keys supplied), three stationary positions, one momentary 5V; ma max Power Status Module (PSM) (00PSM-xxxx) The Power Status Module resides in a local or remote I/O rack containing redundant power supplies. The PSM and second power supply are contained in a rack extension assembly adjacent to the power supply slot position. The PSM module is positioned in a dedicated slot between the two power supplies. Redundant power and the PSM may be used with a Controller rack with local I/O, a Scanner rack with remote I/O controller racks of non-redundant systems and a Scanner rack with remote I/O racks of redundant systems. Directional indicators on the module indicate when both voltage sources of the power supply are operating properly. Type Status indication Power Supply Loading Redundant Power Supply Status indicating Module Green directional indicators using LEDs 5V; ma max

34 ControlEdge 00 Platform Modules Remote Terminal Panels DIN rail mounted Remote Terminal Panels (RTPs) are available for use with pre-wired cables to reduce installation time and labor expense. Three types of RTPs are available: for analog inputs, for relay outputs, and for other I/O modules. Three cable lengths are also available to match hardware to installation variations. Analog input RTPs include transmitter shunt resistors and transmitter power terminals with individual circuit fuses. The Relay Output RTP includes a fuse and power disconnect switch for each output. All RTP panels switch field power to allow module removal and installation under controller power. All RTPs are qualified as non-interfering for SIL- application. Mounting Standard 5mm wide DIN Rail Provides connection of field wiring to controller I/O within an enclosure only. Dimensions. (. mm) x.0 (.0mm) x.0 (.0mm) (L x W x H) Cables High voltage Low voltage Lengths:.0,.5, 5.0 meters. Cable power is limited to Amps per module at 0C (0 degrees F) and Amps at 5C ( degrees F). Lengths:.0,.5, 5.0 meters.

35 ControlEdge 00 Platform Modules 5 Remote Terminal Panel for Analog Input Modules (00RTA-xxxx) The Analog Input RTP integrates some of the typical externally connected components such as switch selectable shunt resistors for current loops and common power supply terminals with individual fuses for powering two-wire transmitters. A power switch is provided to disconnect power from all transmitters for I/O module maintenance. The RTP also minimizes the need for multiple wires under a single screw connection by expanding the connectivity of the shared terminals of the I/O module. The analog input RTP cannot be used for thermocouple inputs. HC00 Terminal Block 5 0 J 0 5 SW () SW () SW () SW () SW 5 () 50 Ohm 50 Ohm 50 Ohm 50 Ohm 50 Ohm TB SW () 50 Ohm SW () 50 Ohm 5 SW () 50 Ohm 0 SW SW SW SW SW SW SW SW () () () 5() () () () () SW F F F F F5 F F F VDC Note: You must set switches - for transmitters Input Input 5 Input Input Transmitter Input Transmitter Input Transmitter Input Transmitter Input Transmitter Transmitter Transmitter Transmitter

36 ControlEdge 00 Platform Modules Remote Terminal Panel for Analog Input Modules (00RTA-xxxx) (cont d) Analog input Module Transmitter power Shunt Resistor Excludes Thermocouple Input types. Accuracy De-rating (Module + RTP) 00 ohm Plat. RTD = +/- 0.% of range JIS RTD = +/-.% of range 0 ohm Cu. RTD = +/-.% of range 0 ohm = +/- 0.% of range 0 0 mv = +/- 0.% of range Common supply terminals selectable per circuit. Fuse per circuit - 0mA, time lag type Selectable per circuit 50 Ohms, 0.05% - 5ppm Remote Terminal Panel for Relay Output Modules (00RTR-xxx) The RTP for Relay Output modules provides individual fuses for each output. A load disconnect switch is also provided for each output to support maintenance of the relay module under instrument power. HC00 Terminal Block J TB F SW 5 0 F SW 5 F SW 0 F SW 0 5 F5 SW5 F SW 5 F SW 5 F SW 5 Relay Output RTP Used with Relay Output Module Relay common disconnect per circuit Fuse per circuit.a, time lag type A maximum per RTP

37 ControlEdge 00 Platform Modules Remote Terminal Panel for Other ControlEdge HC00 Modules (00RTS-xxxx) Remote Terminal Panel(s) may be used with the following ControlEdge HC00 I/O Modules: channel safety UIO module Point Digital Input Module, Contact Type Point Digital Input Module, AC & DC Types Point Digital Output Module, AC type Point Digital Output Module, DC type // Point Analog Output Module Point Digital Input Module, AC/DC types not available Jumpers on the Remote Terminal Panel may be positioned to accommodate the above input and output modules. A switch on the module is used to disconnect field power from I/O modules to facilitate maintenance of the module under instrument power. RTP J J J J5 HC00 Terminal Block 5 0 J 0 J J J J 5 5 5

S200 I/O System Units

S200 I/O System Units S200 I/O System Units S200 I/O is a range of cost effective I/O units which are bus compatible with S200L I/O and can be mixed with them in any order on the same DIN rail. The S200 I/O System features

More information

PACSystems* RX3i IC695MDL765

PACSystems* RX3i IC695MDL765 March 2011 PACSystems* RX3i IC695MDL765 Digital Output Module with Diagnostics 16-Channel The 24/125 volt DC 2A Smart Digital Output module, IC695MDL765, provides 16 discrete outputs in two isolated groups

More information

Industrial Modbus I/O Modules

Industrial Modbus I/O Modules Industrial Modbus I/O Modules Modbus I/O Modules Introduction & Features Digital Input / Output Modules Analog Input / Output Modules Modbus I/O Modules The Best Choice For Your SCADA Applications Introduction

More information

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00 NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www

More information

HC900 Hybrid Controller

HC900 Hybrid Controller Honeywell HC900 Hybrid Controller When you need more than just discrete control Product Note - Pulse/Frequency/Quadrature (PFQ) Module Model 900TCK-0001 The PFQ Module for the HC900 controller is a multi-function

More information

GE Fanuc IC695ALG312. Rx3i PacSystem

GE Fanuc IC695ALG312. Rx3i PacSystem GE Fanuc IC695ALG312 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic695alg312 Rx3i PacSystem GE IP Isolated Thermocouple Input module 12 INPUTS 919-535-3180 sales@pdfsupply.com June 2008

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

Product Information: ExTR Reference No. GB.FME.ExTR

Product Information: ExTR Reference No. GB.FME.ExTR Experion Series C input/output chassis-less mounted modules and field level network gateways provide the physical connection between an automation system and the process when used with the C300 Controller.

More information

Temperature Transmitters - Head Mounted

Temperature Transmitters - Head Mounted XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

SLC 500 RTD/Resistance Input Modules

SLC 500 RTD/Resistance Input Modules Technical Data SLC 500 RTD/Resistance Input Modules (Catalog Numbers 1746-NR4 and 1746-NR8) 1746-NR4 1746-NR8 Inside................... page Hardware Overview............. 2 Module Operation..............

More information

Temperature Transmitters - DIN Rail Mounted

Temperature Transmitters - DIN Rail Mounted XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters The 520 transmitters are universal, isolated, dual-input temperature transmitters with additional voltage and resistance

More information

MINI 048 / JUN 2003 PAGE 1. Temperature I/O Module HE500OCS048 / HE500OCS078 HE500RCS078

MINI 048 / JUN 2003 PAGE 1. Temperature I/O Module HE500OCS048 / HE500OCS078 HE500RCS078 MINI 048 / 078 07 JUN 2003 PAGE 1 Temperature I/O Module HE500OCS048 / HE500OCS078 HE500RCS078 Mini OCS/RCS 1 SPECIFICATIONS Relay Outputs Number of Channels 2 N.O. Relays Maximum Load Current (resistive)

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

C330 / C330X PC-Programmable Universal, 2-wire Transmitter C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and

More information

Assembly. Front view. Parametrization interface. Power Bus

Assembly. Front view. Parametrization interface. Power Bus Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

DeltaV SIS Logic Solver

DeltaV SIS Logic Solver DeltaV SIS Process Safety System Product Data Sheet September 2017 DeltaV SIS Logic Solver World s first smart SIS Logic Solver Integrated, yet separate from the control system Easy compliance with IEC

More information

PACSystems* RX3i IC695ALG600-EE Universal Analog Input Module

PACSystems* RX3i IC695ALG600-EE Universal Analog Input Module June 2017 The PACSystems Universal Analog Input module IC695ALG600 provides eight general purpose input channels and two Cold Junction Compensation (CJC) channels. Inputs are divided into two equal groups

More information

PACSystems* RX3i. Isolated RTD Input Module, 8 Channels, IC695ALG508-CA. Module Features. GFK-2501C November 2012

PACSystems* RX3i. Isolated RTD Input Module, 8 Channels, IC695ALG508-CA. Module Features. GFK-2501C November 2012 November 2012 PACSystems* RX3i Isolated RTD Input Module, 8 Channels, IC695ALG508-CA Isolated RTD Input module IC695ALG508 provides eight isolated differential RTD input channels. Each channel can be individually

More information

Product Specification

Product Specification MODEL NO. WP507F12 This power supply is a small footprint, AC input power supply. This power supply is capable of supplying 400 watts of output power into 5 DC output voltages. 1.0 INPUT REQUIREMENTS 1.1

More information

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and

More information

PACSystems* RX3i IC695MDL664-BB

PACSystems* RX3i IC695MDL664-BB Important Product Information April 2015 PACSystems* RX3i Digital Input Module with Diagnostics 16-Channel 1 2 3 4 5 6 7 8 OK 9 10 11 12 13 14 15 16 S1 S2 IC695MDL664 I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

STT 3000 Smart Temperature Transmitter Series STT170 Specifications STT 3000 Smart Temperature Transmitter Series STT170 Specifications Model STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 November 2010 Overview STT17H Features The Honeywell STT170 series of programmable

More information

Universal Intelligent 2-wire DIN Rail Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version

More information

Modicon Momentum automation platform 0

Modicon Momentum automation platform 0 Presentation, description Presentation The Momentum analog input bases enable acquisition of various analog values encountered in industrial applications, including: b b b b Standard high level (± 5 V,

More information

CompactLogix 5370 L3 Control System

CompactLogix 5370 L3 Control System CompactLogix 5370 Controllers CompactLogix 5370 L1 Control System CompactLogix 5370 L2 Control System CompactLogix 5370 L3 Control System CompactLogix 5370 controllers provide scalable controller solutions

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

Temperature Measurement

Temperature Measurement Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal

More information

SEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER

SEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER UNIVERSAL INPUT, DUAL CHANNEL ATEX & IEC Ex Version MATHS FUNCTIONS SENSOR CHARACTERISTICS DOWNLOAD VIA USB PORT ALLOWS FOR CUSTOM TYPES FLASH TESTED TO 4 KV DC INTRODUCTION The SEM210 is a universal transmitter

More information

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

American Power Design, Inc.

American Power Design, Inc. FEATURES 4 Customer Selects Output Voltage 4 Outputs to 28 Vdc 4 Wide Input Ranges (10-20Vdc, 18-36Vdc, 20-60Vdc, 36-72Vdc) 4 Excellent Line & Load Regulation 4 Low Output Ripple 4 500 Vdc Output Isolation

More information

UniStream Uni-I/O Modules

UniStream Uni-I/O Modules UniStream Uni-I/O Modules Technical Specifications UIS-WCB1 This guide provides specifications for Unitronics Uni-I/O Wide module UIS-WCB1. This module comprises: 10 Digital inputs, 24VDC, sink/source,

More information

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched EXL6 OCS Datasheet for HE- EXL1E0, HE- EXL1E2, HE- EXL1E3, HE- EXL1E4, HE- EXL1E5, HE- EXL1E6 HEXT371C100, HEXT371C112, HEXT371C113, HEXT371C114, HEXT371C115, HEXT371C116 1. Specifications Required Power

More information

SPT. Description. Features. Site-Programmable, Isolated Temperature Transmitter

SPT. Description. Features. Site-Programmable, Isolated Temperature Transmitter SPT June 1999 Data Sheet 3.45 Description Moore Industries SPT Site-Programmable Transmitter is an advanced signal conditioner that packs exceptional flexibility, accuracy, and ease-of-use into a compact,

More information

PACSystems* RX3i and Series 90-30

PACSystems* RX3i and Series 90-30 May 2012 PACSystems* RX3i and Series 90-30 Series 90*-30 Analog Output Module, Current/Voltage, 8 Channel, IC693ALG392 RX3i Analog Output Module, Current/Voltage, 8 Channel, IC694ALG392 The PACSystems

More information

This Errata Sheet contains corrections or changes made after the publication of this manual.

This Errata Sheet contains corrections or changes made after the publication of this manual. Errata Sheet This Errata Sheet contains corrections or changes made after the publication of this manual. Product Family: DL4 Date: September 12, 218 Manual Number D4-ANLG-M Revision and Date th Ed., Rev.

More information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance

More information

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners DRLP Series U ±0.03% Accuracy (Typical) U ±0.01% Linearity U 1500Vrms Transformer Isolation and 240Vrms Field-Side Protection U Wide Loop

More information

Universal Intelligent 2-wire DIN Rail Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

Temperature head transmitter itemp TC TMT 188

Temperature head transmitter itemp TC TMT 188 Technical information TI 077R/24/ae No.: 510 06145 Temperature head transmitter itemp TC TMT 188 Universal head transmitter for thermocouples for an economical, high accuracy temperature monitoring. Fixed

More information

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/. Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

American Power Design, Inc.

American Power Design, Inc. FEATURES 4 Customer Selects Output Voltage 4 Outputs to 28 Vdc 4 Wide Input Ranges (10-20Vdc, 18-36Vdc, 20-60Vdc, 36-72Vdc) 4 Excellent Line & Load Regulation 4 500 Vdc Output Isolation 4 Continuous Short

More information

Universal Intelligent 2-wire In-head Transmitters

Universal Intelligent 2-wire In-head Transmitters Universal Intelligent 2-wire In-head Transmitters Actual size IPAQ-H is a universal and intelligent 2-wire In-head transmitter for temperature and other measurement applications. IPAQ-HX is the Intrinsic

More information

General. Environmental. EMC & Safety

General. Environmental. EMC & Safety AC-DC 400-2500 Watts f lexpower Series Configurable for Fast Time to Market SEMI F47 Compliant xppower.com Flexible Series & Parallel Capability -20 C Operation Extra Power Available at High Line Optional

More information

General Specifications

General Specifications General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supplies 3. SDN-C Compact DIN Rail Series SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs

More information

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

Temperature Measurement Transmitters for mounting in sensor head

Temperature Measurement Transmitters for mounting in sensor head Siemens AG 015 Overview SITANS TH00 two-wire system, universal, HAT Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection

More information

General Specifications

General Specifications General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring

More information

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0. 6.9 Analog input module SM 331; AI 8 x RTD; (6ES7331-7PF01-0AB0) Cycle time extension due to wire-break monitoring The wire-break monitoring software function of the module is available in all operating

More information

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DSA150 Series. xxx Series. 150 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125. 15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty

More information

PACSystems* RX3i IC695ALG600-DD

PACSystems* RX3i IC695ALG600-DD November 2012 The PACSystems * Universal Analog Input module IC695ALG600 provides eight general purpose input channels and two Cold Junction Compensation (CJC) channels. Inputs are divided into two equal

More information

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3 HPU1K5 Series Low Profile 1.7 (43.2 mm), Industrial Supply Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals Output Power up to 1500 W Load dependant variable speed fans for audible

More information

Temperature head transmitter itemp PCP TMT 181

Temperature head transmitter itemp PCP TMT 181 Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

General Specifications

General Specifications General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with

More information

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

USB-TEMP and TC Series USB-Based Temperature Measurement Devices USB-Based Temperature Measurement Devices Features Temperature and voltage measurement USB devices Thermocouple, RTD, thermistor, or semiconductor sensor measurements Eight analog inputs Up to ±10 V inputs*

More information

General Specifications

General Specifications General Specifications GS 0F01D01E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision alarm instrument provided with universal

More information

PACSystems* RX3i IC695ALG600

PACSystems* RX3i IC695ALG600 July 2010 PACSystems* RX3i IC695ALG600 The PACSystems * Universal Analog Input module IC695ALG600 provides eight general purpose input channels and two Cold Junction Compensation (CJC) channels. Inputs

More information

Two-Wire Programmable Transmitter for:

Two-Wire Programmable Transmitter for: TM Smart Process Instrumentation Revision 2 Two-Wire Programmable Transmitter for: Industrial Thermocouple or RTD Temperature Measurements Highlights: Exceptional speed and accuracy Guaranteed measurement

More information

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase Introduction ISOLATD SIGNAL CONDITIONING can significantly increase your system reliability here's how: Linearizes Thermocouple and RTD signals Reduces the demands on the software to linearize the signal

More information

Temperature Measurement Transmitters for mounting in sensor head

Temperature Measurement Transmitters for mounting in sensor head Siemens AG 015 SITANS TH00 two-wire system, universal Overview Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

A6500-UM Universal Measurement Card

A6500-UM Universal Measurement Card Specifications Sheet A6500-UM Universal Measurement Card The A6500-UM Universal Measurement Card is a component of the CSI 6500 ATG machinery protection system. The card is equipped with 2 sensor input

More information

Uni-Mux XQL Multi-Channel Data Acquisition Module

Uni-Mux XQL Multi-Channel Data Acquisition Module Uni-Mux XQL Multi-Channel Data Acquisition Module Uni-Mux XQL Multi-Channel Data Acquisition Module * 8 channel differential inputs. * 16 channel single ended inputs. * User programmable via P.C. software.

More information

GE Fanuc IC695ALG600. Rx3i PacSystem

GE Fanuc IC695ALG600. Rx3i PacSystem GE Fanuc IC695ALG600 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic695alg600 Rx3i PacSystem UNIVERSAL ANALOG MODULE. 8 CHANNELS OF ANALOG CONFIGURABLE IC695A IC695AL IC695ALG 919-535-3180

More information

General Specifications

General Specifications General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring

More information

Multifunction Intelligent 4-wire Isolated Signal Conditioner

Multifunction Intelligent 4-wire Isolated Signal Conditioner Multifunction Intelligent 4-wire Isolated Signal Conditioner IPAQ-4L is a fully universal and intelligent 4- wire (mains powered) transmitter for temperature measurement and signal conditioning applications.

More information

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A. P o w e r C O N T R O L S A N D a t h e n a c o n t r o l s. c o m ATHENA CONTROLS, INC. 5145 Campus Drive Plymouth Meeting, PA 19462-1129 U.S.A. TABLE OF CONTENTS Model Page Series 19/39 1 and Zero-Switched

More information

GE Intelligent Platforms. PAC8000 Modular I/O

GE Intelligent Platforms. PAC8000 Modular I/O GE Intelligent Platforms PAC8000 Modular I/O PAC8000 Modular I/O Overview Overview I/O Modules I/O Modules Overview......................................... 3 2/2 Modules Analog Input...............................................

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Linearized Thermocouple Input 7B47 FEATURES Interfaces, amplifies and filters input voltages from a J, K, T, E, R, S, B or N-type thermocouple. Module provides a precision output of either +1

More information

FC-33, DC SELECTABLE SIGNAL CONDITIONER

FC-33, DC SELECTABLE SIGNAL CONDITIONER FC-33, DC SELECTABLE SIGNAL CONDITIONER Description. The FC-33 is a DIN rail or side mount, selectable input/output signal conditioner with 1500VDC isolation between input and output, and 1500VDC isolation

More information

Industrial Serie +600S

Industrial Serie +600S D A T A S H E E T Industrial Serie +6S Modular Configurable Reduced fan noise Enhanced Line Derating 6 watts in the palm of your hand The +6S series fetures improved low input line derating delivers 6

More information

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features: Characteristics: Front Panel and Features: Ordering Information: Model: D7 D7 General Description: The single and dual channel DIN Rail Temperature Signal Converter D7S and D7D accepts a low level dc signal

More information

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER RTD, THERMOCOUPLE, THERMISTOR (BMS SENSORS), SLIDE WIRE, mv AND RESISTANCE INPUTS ma, VOLTAGE OR BIPOLAR VOLTAGE OUTPUT SENSOR OFFSET (TEMPERATURE) 22 SEGMENT USER LINEARISATION (PROCESS) CONFIGURATION

More information

VersaMax Mixed Discrete / High-Speed Counter Module

VersaMax Mixed Discrete / High-Speed Counter Module Product Description The VersaMax Mixed Discrete High-Speed Counter module, IC200MDD841, has twenty 24VDC positive-logic type inputs and twelve positive-logic 24VDC 0.5Amp outputs. In its default configuration,

More information

D5072. SIL 2 Temperature Signal Converter, Multifunction, DIN-Rail and Termination Board, Models D5072S, D5072D. Characteristics: Technical Data:

D5072. SIL 2 Temperature Signal Converter, Multifunction, DIN-Rail and Termination Board, Models D5072S, D5072D. Characteristics: Technical Data: Characteristics: Front Panel and Features: 5 6 3 1 SIL 11 1 Ordering Information: Model: 1 channel channels D50 D50 SIL according to IEC 6150 for Tproof 5 years ( % of total SIF). Input from Zone 0 (Zone

More information

Mass and Volume Flow Transmitter

Mass and Volume Flow Transmitter IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,

More information

General Specifications

General Specifications General I/O Adaptors (for N-IO) GS 33J62F30-01EN [Release 6] GENERAL This General (GS) describes the hardware specifications of I/O adaptors that enable extended functions setting for analog digital I/O

More information

General Specifications

General Specifications General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.

More information

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i SNAP Isolated Analog Input Modules Features Channel-to-channel isolation Rugged packaging and convenient pluggable wiring. Accepts wire. Factory calibrated; no user adjustment necessary Out-of-range indication

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

DIGITAL PROGRAM CONTROLLER

DIGITAL PROGRAM CONTROLLER KP1000 SERIES DIGITAL PROGRAM CONTROLLER The KP1000 series is a 96x96mm digital program controller with the indicating accuracy of ±0.1%, the control cycle of approximately 0.1 seconds and maximum 19 program

More information

TIY Programmable, Isolated Thermocouple Transmitter combines

TIY Programmable, Isolated Thermocouple Transmitter combines April 2016 Description Moore Industries unique digital/analog hybrid the combines smart digital technology with advanced analog operation to deliver superior reliability, accuracy and ease of use. Microprocessor-based,

More information

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Thermocouple Input 7B37 FEATURES Interfaces, amplifies, and filters input voltages from a J, K, T, E, R, S, or B-type thermocouple. Module provides a precision output of either +1 V to +5 V or

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

Temperature Measurement

Temperature Measurement Temperature Measurement SITANS T00 Overview Application SITANS T00 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective

More information

SafetyNet IO Modules. Safety and Distributed Control. PAC8000 SafetyNet.

SafetyNet IO Modules. Safety and Distributed Control. PAC8000 SafetyNet. SafetyNet IO Modules SafetyNet IO Modules interface to safety system field wiring via Field Terminals. The IO Modules and the Field Terminals mount on Carriers that provide mechanical support, but also

More information

VersaMax Mixed Discrete / High-Speed Counter Module

VersaMax Mixed Discrete / High-Speed Counter Module Product Description The VersaMax Mixed Discrete High-Speed Counter (HSC) module,, has twenty 24VDC positive-logic type inputs and twelve positive-logic 24VDC 0.5Amp outputs. In its default configuration,

More information

Electronic Circuit Protector ESX10

Electronic Circuit Protector ESX10 Electronic Circuit Protector ESX0 Description Electronic circuit protector type ESX0 is designed to ensure selective disconnection of DC 24 V load systems. DC 24 V power supplies, which are widely used

More information

Efficiency (typ.) (Range) Load. Output Current Input Current Reflected Ripple

Efficiency (typ.) (Range)  Load. Output Current Input Current Reflected Ripple FEATURES Highest Power Density 1" x 1" x 0.4" Shielded Metal Package Ultra Wide 4:1 Input Range Excellent Efficiency up to % Operating Temp. Range - C to + C Optional Heatsink I/O-isolation Voltage 10VDC

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information