1 / Controller -0/1 Series Features Consolidated (Maintenance ) - The -0 series consolidates nine counters into one unit and the -1 series consolidates eight counters (timers) into one unit. - These counters notify the maintenance period of several tools, as needed f tool replacement with machining centers and NC machine tools. - Tool management: Replacement prediction / warning - Whetstone f polishing: Maintenance prediction - Quantity management: Total counter / Preset counter - Time management: Integrating timer Features -0 Series The counter features counting inputs, a preset function and independent prediction output (count up output), and outputs when either one of the counters reaches the equipment stop set value. -1 Series The counter features counting inputs, a preset function and independent prediction output (count up output), and outputs when either one of the counters (Timers) reaches the equipment stop set value. Open collect output: -0 (Japanese surface sheet) -0-1 (English surface sheet) Open collect output: -1 (Japanese surface sheet) -1-1 (English surface sheet) Voltage output: -0P (Japanese surface sheet) -0P-1 (English surface sheet) - Nine -digit preset counters (timers) are consolidated into one unit. - Battery-less The set value / discrete value are memized by a maintenance-free EEPROM. - Individual prediction (preset) outputs f circuits - Indications of the previous prediction (green) - prediction (ange) - facility stop (red) are distinguished by col. A previous prediction display function that notifies that the value is close to the prediction set value is built-in. - stop output An over-value is set f the prediction set value of each counter, and when any one of the counters reaches the over-value, the equipment stop is output (red display). - preset counters can be used as a total counter Each counter can independently preset value s(prediction setting) and individually count the inputs and outputs against the preset value (ange display). - Oilproof front operation panel - Miniature (DIN x mm) The overall depth is mm, so the control panel is thin. - Eight -digit preset counters (timers) are consolidated into one unit. - Battery-less The set value / discrete value are memized by a maintenance-free EEPROM. - Individual prediction (preset) outputs f circuits - Each counter (timer) displays a different col when the set value is reached. Setting 1 (green) - Setting (ange) - Setting (red) - output When any one of the counters (timers) reaches the value of setting 1 setting, the output is produced. - preset counters can be used as a total counter a integrating timer. The counter / timer functions can be mixed in use. - Any counter / timer can be reset by external signal. - Oilproof front operation panel - Miniature (DIN x mm) The overall depth is mm, so the control panel is thin. GENERAL CATALOG 01 Latest catalog (free) is available online. Visit our website

2 / Controller Application -0 Series Tool Maintenance of Multiple Spindle Machine Tools 1 Processing Count 1-0/1 Series Features -1 Series Tool Maintenance of Multiple Spindle Machine Tools 1 Processing Count Timekeeping 1 Facility Output Lamp / Buzzer /Facility, etc. Output 1 Output Output Output Lamp / Buzzer /Facility, etc. Setting Output 1 Setting Output Output Setting Note 1) s to perfm similar operation. ) The equipment stop output and the equipment stop display turn on when any one of the counters, 1 to, reaches the equipment stop set value. Note 1) s / Timers to perfm similar operation. ) The output turns on when any one of the counters (timers), 1 to, reaches the value of setting 1 (setting ). Basic Operation -0-0 Series Time Chart Current Values (Count Values) Current Values (Count Values) Set Value Set Value Set Value Set Value Previous Previous Set Value Set Value No.1-1 Series Time Chart Current Values (Count Values/Timing Value) Setting 1 Setting Setting 1 /Timer No.1-1 Green Orange Count 1 Green Orange Red Count 1 Green Orange Red Previous /Alarm Previous /Alarm Display Display Display Display Output Output H (OFF) H (OFF) Facility Output Facility Output L (ON) L (ON) (External Key ) (External Key ) Setting 1/Setting Display Setting Output Output (External Key ) Green Orange Green Orange Red Count/Timer 1 H (OFF) L (ON) The specifications and prices described in this catalog were valid when the catalog was issued. F the latest infmation, contact our sales persons see our website. GENERAL CATALOG 01

3 / Controller -0/1 Series Each Part Name and Function Panel Explanation -0 Series key - s the displayed current value. - When several counters are counting up and the reset operation is perfmed, the counter display switches to the next counter. Mode display - Either previous prediction, prediction, equipment stop is displayed in the setting mode. When all the lights are turned off, the device is the operation run mode. No. display - Displays the selected counter No. - Ever y time the counter counts up (prediction set value), the counter No. switches to the No. of the counter that overflowed. No. Previous Setting No. Mode Selection Selection Current Value Set Value Set Setting key No. selection key - Switches the display between the current value and the set value of the counter. - s that are not used in the run mode are not displayed. longer, the counter No. automatically changes. Count-up display (GreenOrangeRed) - Green: Shows that the value reached the previous prediction set value. - Orange: Shows that the value reached the prediction set value. - Red: Shows that the value reached the equipment stop set value. stop display (Red) - Shows that one of the counters reached the equipment stop set value. Current value display - Displays the current value of the counter by counter No. Zeros of high-der digits are out in the run mode. Set value display - Displays the set value of the counter (prediction, previous prediction, and equipment stop) by counter No. Zeros of high-der digits are out in the run mode. Setting mode selection key - Switches between the run mode and the setting mode. If there is no key entry f 1 minute longer, the mode automatically switches to the run mode. Key (Digit selection key) - Selects the digit f inputting the set value. - The selected digit flickers. + Key (Numeric value changing key) - Changes the numeric value of the digit selected by the key. Set key - Enters the set value in memy in the setting mode. When the set value is entered, the set value display flickers three times, indicating the input. GENERAL CATALOG 01 Latest catalog (free) is available online. Visit our website

4 / Controller -0/1 Series Each Part Name and Function Panel Explanation -1 Series key - s the displayed current value. - When several counters are counting up and the reset operation is perfmed, the counter display switches to the next counter. Mode display - Either setting 1, setting, setting is displayed in the setting mode. When all the lights are turned off, the device is the operation run mode. display - Displays the selected counter / timer No. - Every time the counter / timer counts up (setting ), the counter / timer No. switches to the No. of the counter that overflowed. Setting 1 [Green] Selection Setting 1 Setting Setting Mode Setting [Orange] Setting [Red] Current Value Setting key selection key - Switches the display between the current value and the set value of the counter. - s/timers that are not used in the run mode are not displayed. longer, the counter No. automatically changes. Mode key - Switches between the run mode and the setting mode. - If there is no key entry f 1 minute longer, the mode automatically switches to the run mode. Red h Orange min Set Value Set Green s Count-up display (GreenOrangeRed) - GreenShows that the value reached the Setting 1. - OrangeShows that the value reached the Setting. - RedShows that the value reached the Setting. Timing unit display - Displays the timing unit by col during timer operation. - Green: The time unit is in seconds. - Orange: The time unit is in minutes. - Red: The time unit is in hours. Current value display - Displays the current value of the counter/ timer by Zeros of high-der digits are out in the run mode. Set value display - Displays the set value of the counter/ timer (Setting 1, setting, and setting ) by Zeros of high-der digits are out in the run mode. Key (Digit selection key) - Selects the digit f inputting the set value. - The selected digit flickers. + Key (Numeric value changing key) - Changes the numeric value of the digit selected by the key. Set key - Enters the set value in memy in the setting mode. When the set value is entered, the set value display flickers three times, indicating the input. The specifications and prices described in this catalog were valid when the catalog was issued. F the latest infmation, contact our sales persons see our website. GENERAL CATALOG 01

5 / Controller Count-up Display Display Count 1 + V -0/1 Series 1 V DC±10% Output1 Count-up Current DisplayValue Display Display + V Count 1 No. + V Supply Display 1 Set Value Display Output Output1 No. Display digits Set -stage Value Display Counting Speed Switching Preset V DC±10% No. Selection Count-up Display Display + V Supply Count 1 digits + -stage V Supply 0 CPU V Nmal 1 + Counting Speed Switching Preset No. Selection Current Value Display Output1 V DC±10% No. Display Set Value Display + 0 *1 V V DC±1% V DC±10% V DC±10% * Count-up Display Display + V Count 1 + V Supply digits -stage *1 V DC±1% 1 Counting Speed Switching Preset V DC±10% No. Selection IN Count-up Current DisplayValue Display Output1 * Display + V Count 1 No. + RUN V Output Supply Display 1 Set Value Display + V DC±10% Output1 No. Display digits Set -stage Value Display *1 V DC±1% Counting Speed Switching V DC±10% Preset * Count-up No. Selection Display Display + V Count 1 + V Supply digits -stage 1 Counting Speed Switching Preset Output1 No. Selection No. Display Set Value Display digits -stage Counting Speed Switching Preset No. Selection *1 Negative Logic * Positive Logic Inpu Connection Block Diagram -0-0P Function Supply + V V DC±10% *1 Negative Logic * Positive Logic Inpu -0 *1 Negative Logic -0P * Positive Logic Inpu *1 + V DC±1% V DC±1% Terminal Number /Output Description of Functions Specifications * Count/Time-up Display Timer Display + V C/T The 1 current value of the relevant counter is added (+1) + V regardless Supply of the,,, 1, 1, 1, 1, Count input *1 + V DC±1% Counting speed 0/00-0 operation mode / 1setting mode. The current value changes by HL and Output 0, 1 1 to Hz voltage V DC±1% * LH (positive logic). Count/Time-up Current Display Value Display Setting Output 1 Timer Display + V ON: 0 to V C/T 1 + V Supply OFF: 1 V higher Counting speed OFF: 0 Hz Switched by the ON edge 1 Display 1 Set Value Display Output resistance:. kω switching input ON : 00 Hz of the power supply Setting Output 1-0P voltage selection C/T input No. 1 No. Selection B0 Display digits Set -stage Value Display On delay: 0 ms (Negative logic) The counter No. changes by the counter selection input HL and LH selection input Off delay: 0 ms ON: 0 to V (positive B1 logic). In the Preset operation mode, unused counters are not selected. OFF: is open B (timer) (Positive logic) BA Supply Selection The B0current value of the digits counter -stage designated by the counter No. is reset. If ON: 1 to. V On delay: s the B1counter No. selection Preset input and the input reset input are simultaneously *1 Negative OFF: Logic 0 to V Off delay: B (timer) V 0.1 DC±1% s input f approx. seconds, all counters are reset. * Positive Logic resistance: Inpu. kω BA -1 1,,,,, 10, 1, 1, The prediction output is output if the individual output of counters Nos. 1 to + *1 Negative Logic 1 output 1 to reaches the prediction set value. /Output response time V DC±1% * Positive Logic Inpu 0 ms (0 Hz) 10 ms (00 Hz) stop output The equipment stop set value is output if one of the counters Nos. 1 to reaches the equipment stop set value P -0P RUN output -0-0 No. display V V. kω ON when the CPU nmally operates / OFF when the CPU does not operate nmally. The counter No. selected with the counter No. selection key by the external counter No. selection input is displayed. Every time the counter counts up, the counted counter No. switches to the counted up No. (ranked by priity). Priity: stop > > Previous prediction V Output Output V Output Output Up to V DC/0.1 Output A Response time ON: After the power is supplied 1. s less OFF: *1 Negative After an Logic abnmality is detected 10 ms less * Positive Logic Inpu Notes 1) and V are connected inside the counter. ) and are connected inside the counter. Notes 1) and V are connected inside the counter. ) and are connected inside the counter.. kω Up to V DC/0.1 A -0 V Output V -0P V V -0P. kω. kω KOYO ELECTRONICS. INDUSTRIES kω CO., LTD. GENERAL CATALOG 01 V Output V Notes 1) and Output Note) V are connected and inside V are the connected counter. inside the counter. ) and are connected inside the counter. Output V Output Up to V DC/0.1 OUT A Output Latest catalog Output (free) is available online. Note) and V are connected inside the counter. Visit our website

6 No. Selection *1 Negative Logic / Controller * Positive Logic Inpu -0/1 Series Connection Block Diagram -1 *1 + V DC±1% * C/T 1 Selection B0 B1 B BA Count/Time-up Display 1 Display Set Value Display digits -stage Preset (timer) Timer Display + V Supply V DC±1% + V Output Setting Output 1 + V DC±1% *1 Negative Logic * Positive Logic Inpu P Function 1,, Terminal Number /Output Description of Functions Specifications,,, 1, 1, 1, 1, 0 1 V. kω 1,,,,, 10, 1, 1 C/T input 1 to V selection input 1 to All selection input. kω output The counting (timing) of the relevant counter (timer) is perfmed regardless of the operation mode / setting mode. - When the -0/1 is used as a counter: The current value changes when "OFF""ON". - When the -0/1 is used as a timer: Timing range voltage The timing starts when "OFF""ON". Hour 1 to, h (Negative logic) The timing continues while "ON". Minute 1 to, m ON: 0 to V The timing stops when "OFF""ON". Second 1 to, s Output Notes 1) and V are connected inside the counter. OFF: is open Output ) and are connected inside the (Positive counter. logic) The counter / timer RUN you Output want to reset is designated by three inputs (B0, B1, and B). Up to V DC/0.1 A When you want to designate all counters / timers at the time of a reset input, this input should be ON. The current value of the selected counter / timer No. becomes 0 (zero). 11 RUN output This is output if one of the counters / timers Nos. 1 to reaches the setting Output 1 (setting ) value. ON when the CPU nmally operates / OFF when the CPU does not operate nmally. Counting speed 0 Hz/00 Hz Minimum pulse width 1. ms/1 ms On delay: 0ms Off delay: 0ms V Setting Output This is output if the individual V output of counters / Note) timers IN Nos. 1 and to V are connected inside the counter. output 1 to reaches the setting OUT value. /Output response time 0 ms (0 Hz timer) 10 ms (00 Hz) ON: 1 to. V OFF: 0 to V resistance:. kω Response time ON: After the power is supplied 1. s less OFF: After an abnmality is detected 10 ms less / Timer No. display function The counter No. selected with the counter / timer No. selection key by the external selection input is displayed Default setting: If the "mode" Vkey and the Output "+" key are simultaneously pressed, the default setting mode starts Notes to initialize 1) the Common following data. 0 V: Positive Logic Setting Output (1) Selection of the counter and timer, () Setting of the counting speed and timing unit, () Prohibition/Permit selection V: of Negative the reset key, Logic and () Selection of the set value concerning the Output, output (Setting 1 setting ) Open Collect ) Output Common -1: 0 V and Internally Sht circuited. kω -1. kω V Output Notes 1) Common 0 V: Positive Logic Setting Output V: Negative Logic Output, Open Collect ) Output Common -1: 0 V and Internally Sht circuited The specifications and prices described in this catalog were valid when the catalog was issued. F the latest infmation, contact our sales persons see our website. GENERAL CATALOG 01

7 / Controller -0/1 Series General Specifications/Dimensions General Specifications (Commonly Used in -0/1 Series) Items Supply Voltage Consumption Use Ambient Temperature Stage Temperature Use / Stage Ambient Humidity Insulation Resistance Dielectric Voltage Noise Resistance Vibration Resistance Impact Resistance Case Exteri Weight Price P -0P Model Number (Accessies) Mounting bracket Specifications -0 series: V DC10% (1. to. V) -1 series: V DC1% (0. to. V) W -10 to + C -0 to +0 C (No freezing) to % RH (No condensation) 100 MΩ higher00 V DC (Between power supply terminal and input-output terminal) 00 V AC0/0 Hz 1 min (Between live parts and externally-exposed non-charged metal part) Between power supply terminals: 1 kv (Pulse width 1 μs, start-up 1 ns) Between input terminals: 00 V (Pulse width 1 μs, start-up 1 ns) Malfunction vibration: Displacement amplitude 0. mm 10 to Hz, axial directions Endurance vibration: Displacement amplitude 0. mm 10 to Hz, axial directions m/s, axial directions Munsell N- (dark gray) ABS material 0 g Price Open Open Terminal Assignment -0 Series Output Count RUN Operational Output Speed Count +V 0V OUT IN -1 Series No. 1 1 Output 1 Setting 1/ Setting Output C/T RUN N.C BA B0 Setting Output C/T Selection +V 0V OUT B1 B IN Dimensions (Unit: mm) Thickness of Mounting Plate 1 to Mounting Bracket Current Value No. Set Value Setting No. Mode Display Selection Set Square Hole GENERAL CATALOG 01 Latest catalog (free) is available online. Visit our website

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm. Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital

More information

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.

More information

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2. Conforms to EMC standards (EN50081-2 and EN50082-2). Approved by UL and CSA. Lloyds/NK

More information

Self-powered Tachometer

Self-powered Tachometer Self-powered Tachometer H7ER Revolutions displayed up to five digits. Dual revolution display accding to encoder resolution used; 1000 s 1 /1000 min 1 1000.0 s 1 /1000.0 min 1 Switchable dual revolution

More information

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Ordering Information. Stepping Relay Unit G9B. Model Number Legend Stepping Relay Unit CSM DS_E_4_1 Ideal for Controlling Pumps and Production Lines with Six or Twelve Stepping Circuits Built-in relays switch 2 A at 250 VAC or 30 VDC. Initialization of stepping with reset

More information

Count/Time Totalizers

Count/Time Totalizers /Time Totalizers Compact or Time Totalizers with Easy-to-Read and NEMA 4 Protection High-visibility, 8.5 mm negative transmissive LCD. NEMA 4 when used in conjunction with Y92S-32 rubber gasket supplied

More information

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz 8 Pin Plug Type DIN W48 H48mm 8 Pin Plug Features Upgraded counting speed: 1cps / 3cps / kcps / 5kcps Selectable voltage input (PNP) method or no-voltage input () method Decimal point setting (fixed decimal

More information

WHEN A PLC IS TOO MUCH, AND SPACE FOR

WHEN A PLC IS TOO MUCH, AND SPACE FOR WHEN A PLC IS TOO MUCH, AND SPACE FOR A RELAY SEQUENCE CIRCUIT IS TOO LITTLE Pattern Selector 59 2.33 66 2.6 70 2.75 No programming required Select from among 15 preset patterns Wiring far simpler than

More information

Multi Function Timer with Free power, Compact size W38 H42mm

Multi Function Timer with Free power, Compact size W38 H42mm Multi Function with Free power, ompact size W8 H4mm Features Wide power supply range : 100-40VA 50/0Hz, 4-40VD (universal), 4VA 50/0Hz / 4VD (universal), 1VD Various output operations( operation modes)

More information

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

High Reliability Of Fiber Optic Amplifier For Convenient Mounting Amplifier Reliability Of Amplifier For Convenient Mounting Features speed response: Max. 0.5ms Auto (Button setting)/remote synchronization input, mutual interference protection, selfdiagnosis Reverse

More information

Solid-State Digital Counter H7AN

Solid-State Digital Counter H7AN Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or

More information

Analog Timer TTL Series

Analog Timer TTL Series Analog r TTL Series Part Number Description TTL - ❶ ❷ ❸ ❶ Pin Type 8 : 8Pin Socket and Panel mounted ❷ Timing Mode A : A, A1, F1, I B : A, A1, B, F ❸ Supply Voltage 110/220VAC 24VDC 110VDC General Specification

More information

General-Purpose Photoelectric Sensors with Self-Contained Amplifier

General-Purpose Photoelectric Sensors with Self-Contained Amplifier General-Purpose Photoelectric Sensors with Self-Contained Amplifier HP Series The convenience of industry standards, plus reliability. Effective light axis alignment 50% power savings Prevention of accidental

More information

Resolution (divisions) 256, 360, , 360, 720, 1,024 Pre-wired Model

Resolution (divisions) 256, 360, , 360, 720, 1,024 Pre-wired Model Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-110020(India) Tel : 011-4797575 Fax : 011-4797574 E-mail : sales@ashalain.com Absolute 60-mm-dia.

More information

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC

More information

Rotary Measuring Technology

Rotary Measuring Technology SSI or parallel interface Highest shock resistance on the market ( 2500 m/s2, 6 ms acc. to DIN IEC 68-2-27) Divisions: up to 16384 (14 bits), singleturn Housing Ø 58 mm IP 66 Various options (e.g. LATCH,

More information

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES High Carrying Current Type Miniature Low Profile Automotive Relay CP RELAYS POWER TYPE Sealed 13.1 14.1 9..374 FEATURES Maximum carrying current of 3 A (4 mw type, 1 V applied)

More information

WARNING. 5 Mounting. 1 CE marking. 2 Confirmation of packed content. 3 Safe use of laser product. 4 Part description. Instruction Manual

WARNING. 5 Mounting. 1 CE marking. 2 Confirmation of packed content. 3 Safe use of laser product. 4 Part description. Instruction Manual Instruction Manual Micro Laser Sens (CMOS) HG-C Series ME-HGC000VEN Thank you very much f purchasing Panasonic products. Please read this Instruction Manual carefully and thoughly f the crect and optimum

More information

Power supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model

Power supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model 60-mm-dia. Encoder Rugged Encoder for High-precision Detection of Automatic Machine Timing Rugged construction with the highest shaft loading. Radial: 120 N, Thrust: 50 N IP65f water- and oil-proof construction.

More information

Remote Sensor Amplifier Terminal

Remote Sensor Amplifier Terminal 9 Remote Sensor Amplifier Terminal Plug-in Sensor Amplifiers with Direct CompoBus/S Terminal Connections 1 SRT1 models support only high-speed communications systems 1 4-point terminals expand to 8 points

More information

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches Weekly Timer Timer Provides Prompted Programming, Flexibility in Programs Within the Week AM/PM display 24 program steps A different program possible each day Over midnight settings possible Two independent

More information

Self-powered Counter

Self-powered Counter Self-powered Counter Subminiature Totalizing Counter Requires No External Power Supply DIN-sized 48 24 mm Wire-wrap terminal and screw terminal types available. AC/DC voltage, DC voltage, and No-voltage

More information

Solid-state Twin Timer

Solid-state Twin Timer Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time

More information

Z500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System

Z500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System Profile Measuring System High-Precision Sensor that Measures and Displays an Object's Profile. Features OMRON's original line beam method provides a complete solution to profile measurement problems. Conventional

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

Digital Fiber-Optic Switches

Digital Fiber-Optic Switches CP-PC-2259E Digital Fiber-Optic Switches Model HPX-EG0 0/01 : Standard Model HPX-EG/ 51 : Long-dis tance Sensing Satisfaction Freedom from Frequent Adjustments Please read Terms and Conditions from the

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT PCB Relay A Power Relay with Various Models High-sensitivity ( mw) and High-capacity ( A) Models available. Low profile:.7 mm max. in height Conforms to VDE (EN0-), UL and CSA.. Meets EN0- requirements

More information

Emitting and receiving element pitch: 10 mm in

Emitting and receiving element pitch: 10 mm in Small / Slim Object Detection Area Sensor Cross-beam scanning system to detect slim objects Letter or visiting card detectable! Slim objects can be detected by using the cross-beam scanning system. Emitting

More information

HVR. Lead Wire Length (H, mm)

HVR. Lead Wire Length (H, mm) High Resistor Features Special conductive film withstands high voltage d L H D working voltage far over that of generalpurpose resistors Suitable for applications such as TV s, high voltage power supply,

More information

Solid-state Timer H3DE

Solid-state Timer H3DE Solid-state Timer H3DE DIN-rail Mounted, Standard 22.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except for H3DE-H) 12-VDC

More information

G2RV-SL Slim I/O Relay will be discontinued February 2019

G2RV-SL Slim I/O Relay will be discontinued February 2019 NO: RL-162 PRODUCT: G2RV-SL Slim Relay DATE: February 2018 TYPE: Discontinuation Notice G2RV-SL Slim I/O Relay will be discontinued February 2019 Discontinuation Date: February 2019 Note: Date is subject

More information

Rotary Measuring Technology

Rotary Measuring Technology Our ATEX encoders now also carry approval for Dust Flameproof-enclosure type of construction with approval for Zone 1 and 21 ExII2GEExdIICT6 and ExII2DIP6xT85 C Shaft ø 12 mm One type for every situation:

More information

Indicator (4digit) (5digit) 8-pin plug counter

Indicator (4digit) (5digit) 8-pin plug counter 8 Pin Plug type DIN W8 H8mm 8 Pin plug counter Features Upgraded counting speed : 1cps / cps / 2kcps / 5kcps Decimal point setting(fixed decimal point of display) Wide range of power : 1-2VAC 5/6Hz 12-2VAC

More information

Safety Precautions. Copyright / Trademarks

Safety Precautions. Copyright / Trademarks Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure

More information

Diameter ø50mm Shaft type Absolute Multi-turn Rotary Encoder

Diameter ø50mm Shaft type Absolute Multi-turn Rotary Encoder Dia ø50mm Shaft type Absolute Multi-turn otary Encoder Features Compact size of dia ø50mm Parallel data / SSI data transmission type Total 23bit resolution(8388608 divisions) of 10bit single-turn(1024

More information

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information. / Length Micro Sensor LED-type Micro Sensor with Many Features in a Compact Body Compact body only /4th the volume of our previous product. % cost reduction over our previous product. High performance

More information

Self-Powered Counters H7ET

Self-Powered Counters H7ET Self-Powered Counters Subminiature Time Totalizers Require No External Power Supply Subminiature 8 x 2 mm (1.89 x.9 in) Improved noise immunity Screw terminal and wire-wrap types available Printed circuit

More information

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj Ratchet Relay Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation at each pulse input

More information

Tactile Switch. Ordering Information. A Wide Range of Models: 6 6 mm, mm, Side-operated, High-force, and Gold-plated.

Tactile Switch. Ordering Information. A Wide Range of Models: 6 6 mm, mm, Side-operated, High-force, and Gold-plated. Tactile Switch BF A Wide Range of Models: mm, mm, Side-operated, High-force, and Gold-plated. Extended mechanical/electrical durability: 0 x 0 operations for x mm type and x 0 operations for the x mm type

More information

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier Ultraminiature Photoelectric Sensors with Self-contained Amplifier HPJSeries HPJ Fingertip-size, Provided with a various slit attachments. (six types) Fingertip-size 22 x 11 x 8mm (thru scan model) 30

More information

Cylindrical type proximity sensor

Cylindrical type proximity sensor Cylindrical type Cylindrical type proximity Features Improved the noise resistance with dedicated IC Built-in reverse polarity protection circuit (DC 3-wire type) Built-in surge protection circuit Built-in

More information

New 1. Temperature unit P J K R. N Indicator. X 12-24VDC VAC 50/60Hz. Indicator Alarm/Sub output. I Indicator

New 1. Temperature unit P J K R. N Indicator. X 12-24VDC VAC 50/60Hz. Indicator Alarm/Sub output. I Indicator T3 / T4 Series Features Various size as DIN specifications (W H24, W72 H36, W96 H, W H, W H96, W72 H72, W96 H96mm) Please read Safety Considerations in operation manual before using. Ordering Information

More information

Model Number Structure

Model Number Structure Total Counter/Time Counter (DIN 72 x 36) CSM DS_E_4_1 DIN 72 x 36-mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 Large, easy-to-read displays:

More information

Remote Sensor Amplifier Terminal

Remote Sensor Amplifier Terminal 9 Remote Sensor Amplifier Terminal Plug-in Sensor Amplifiers with Direct CompoBus/S Terminal Connections 1 SRT1 models support only high-speed communications systems 1 4-point terminals expand to 8 points

More information

Opaque materials of Min. Ø60mm. Hysteresis - Max. 10% at rated setting distance

Opaque materials of Min. Ø60mm. Hysteresis - Max. 10% at rated setting distance Small and light, common type Features Easy to mount at a narrow space with small size and light weight. Convenient to adjust the sensitivity by external sensitivity adjustment control.(diffuse reflective

More information

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage TESTING ULTRA LOW PROFILE POLARIZED RELAY RELAYS 9...7 mm inch FEATURES Low profile mm.7 inch height High contact capacity: Surge withstand between contact and coil:, V (Telcordia) RoHS Directive compatibility

More information

PLC-K506 Series FEATURES DESCRIPTION FEATURES

PLC-K506 Series FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate With Up to 32 Devices DESCRIPTION

More information

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224 No. CP-SS-E // Dot Printing Model Smart Recorder SRF0// The Smart Recorder SRF 0// Dot Printing Model accepts DC voltage, thermocouple, resistance temperature detector (RTD), communications and ON/OFF

More information

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: DA3. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT D/A CONVERTER (16-bit resolution) Functions & Features Converts parallel digital signal into a DC output BCD, binary, offset binary, two's complement, reflected binary

More information

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS 20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,

More information

A new approach to static electricity countermeasures

A new approach to static electricity countermeasures Advanced intelligent Sensors NEW ELECTROSTATIC SENSOR EF-SSERIES A new approach to static electricity countermeasures Measurement of surface potentials while a production line is running Phone: 8.894.42

More information

VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE Page 1 of 7

VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE Page 1 of 7 Page 1 of 7 No entry if additional Model Code / Additional Spec. Code ( spec. code is not specified. ) VM-701B /PM /AL Phase Marker Function Analysis Function 0 Without 0 Without With Y With 1 (When /ALY

More information

Micro-ISO Automotive Relay. (Unit: mm inch)

Micro-ISO Automotive Relay. (Unit: mm inch) Micro-ISO Automotive Relay CM RELAYS Flux tight/sealed.. FEATURES Micro-ISO type terminals and small size Wide line-up Compact and high-capacity switching... TYPICAL APPLICATIONS

More information

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C T Series nalog nd Non-Indicating Type, PID Control, Set y Dial Features Improved control performance with built-in microcomputer dopting new uto-tuning PID control algorithm : Selectable ON/OFF, PID control

More information

RK RELAYS FEATURES. SPECIFICATIONS Contact. 1.5 GHz MICROWAVE RELAY

RK RELAYS FEATURES. SPECIFICATIONS Contact. 1.5 GHz MICROWAVE RELAY . GHz MICROWAVE RELAY RK RELAYS..79.. 9.7.3 mm inch FEATURES Excellent high frequency characteristics (Impedance 7Ω) Isolation: db (at. GHz) Insertion loss:.db (at 9 MHz) :. (at 9MHz) High sensitivity

More information

High Speed Response Type With Built-in Output Protection Circuit

High Speed Response Type With Built-in Output Protection Circuit High Speed Response Type With Builtin Output Protection Circuit Features Reverse power polarity and overcurrent High speed response: Max. ms ight /Dark mode selectable by control wire Builtin the sensitivity

More information

Timers GE1A. GE1A Series ON Delay Timers Single Function

Timers GE1A. GE1A Series ON Delay Timers Single Function Key features: DPDT or SPDT + instantaneous SPDT 8-pin, octal base 8 time ranges Repeat error ±0.2% maximum Large, clear knob for easy setting Instant monitoring of operational status by LED indicators

More information

NPN PNP NPN PNP NPN PNP

NPN PNP NPN PNP NPN PNP Cam Positioner Low-Cost, High-Performance Electronic Cam Switch for Use with OMRON E6F Rotary Encoder Control outputs can be programmed to turn ON/OFF in 1 units of rotary encoder shaft rotation Handles

More information

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate with up to 32 devices DESCRIPTION

More information

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291 COMP SIZE HIGH PRECISI IMERS VARIOUS OUPU & OPERAI MODE YPES SDX (one) SDX imers Features UL File No.: E22222 CSA File No.: LR3929 3 operation modes added for fuller lineup Now, operation modes include

More information

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

1.5 GHz MICROWAVE RELAYS. FEATURES 1. Excellent high frequency characteristics. V.S.W.R. (Max.) 1.5 (at 900 MHz) Impedance

1.5 GHz MICROWAVE RELAYS. FEATURES 1. Excellent high frequency characteristics. V.S.W.R. (Max.) 1.5 (at 900 MHz) Impedance 1.5 GHz MICROWAVE RELAYS RK RELAYS RoHS compliant FEATURES 1. Excellent high frequency characteristics V.S.W.R. () 1.5 (at 9 MHz) Impedance 5Ω Impedance 75Ω Insertion loss (db. ) Isolation (db. ) V.S.W.R.

More information

PCB Footprint Max.Load Coil Voltage Non-Latching part number Single-coil latching part number Standard ground terminal (1GHz)

PCB Footprint Max.Load Coil Voltage Non-Latching part number Single-coil latching part number Standard ground terminal (1GHz) High Frequency Relay G6K-RF Surface Mount, 1GHz / 3 GHz Miniature DPDT, High Frequency Relay New Models with 3 GHz band available ( -T versions) Space-saving 1 GHz version with smaller ground terminal

More information

LOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max.

LOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max. TESTING LOW-PROFILE SURFACE-MOUNT RELAY RELAYS 5.6. mm inch FEATURES Low-profile: 6 mm.36 inch in height comforming to EIA standards (Tape height: max. 6.5 mm.56 inch ) Tape and reel package is available

More information

High Speed Response Type With Built-in Output Protection Circuit

High Speed Response Type With Built-in Output Protection Circuit Amplifier Builtin Type By Side High Speed Response Type With Builtin Output Protection Circuit Features Reverse power polarity and overcurrent High speed response: Max. ms ight /Dark mode selectable by

More information

FX-CM. HQ Color Mark Sensor. Model Number Legend SALIENT FEATURES. Sensors. Proximity. Photoelectric. Sensors

FX-CM. HQ Color Mark Sensor. Model Number Legend SALIENT FEATURES. Sensors. Proximity. Photoelectric. Sensors HQ Color Mark Sensor SALIENT FEATURES 18mm ±2mm Pushbutton Teach RGB LED light source 8 Remote Memory Setting Shock Resistant casing - 50G Model Number Legend 1 2 3 4 5 1. Series 4. Output FX 2. Type CM:

More information

0.01kV (0 to ±0.99 kv)

0.01kV (0 to ±0.99 kv) Handheld Electrostatic Meter Series IZH10 Easy-to-use handheld electrostatic meter Rated charge amount range: ±20.0 kv Minimum display unit: 0.1kV (±1.0 to ±20.0 kv) Check the current situation before

More information

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22. Measuring and Monitoring Relays K8AB Series Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.5 mm Eight slim models featuring a variety of innovative new functions. Single-phase

More information

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Solid-state Timer CSM DS_E_

More information

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information Latching Relay CSM DS_E Compact Mechanical Lock Latching Relays with Manual Buttons Compact design with a height of 7 mm, width of. mm, and depth of 8. mm. Plus, one Relay only weighs 7 g. Quick set and

More information

Monitoring voltages of 3-phase 4 wires with a single unit

Monitoring voltages of 3-phase 4 wires with a single unit VOLTAGE RELAY PTS TYPE High-performance under-voltage relay that activates output when all 3-phase voltages fall below a reference voltage by monitoring voltage on each phase of 4 wires FEATURES Monitoring

More information

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2 Miniature Relay for Signal Circuits ROHS compliant. Wide switching power of 10 µa to 2 A. High dielectric strength coil-contacts:1,000 VAC; open contacts: 750 VAC. Conforms to FCC Part 68 requirements.

More information

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately) Cylindrical Proximity Sensor in Plastic Housing High quality full body plastic housing for high water proof requirements Polyarylate housing for light chemical resistance Applications Detection of bottle

More information

Single-phase Current Relay

Single-phase Current Relay New Product Single-phase Current Relay K8AB-AS Ideal for current monitoring for industrial facilities and equipment. Monitor for overcurrents or undercurrents. Manual resetting and automatically resetting

More information

12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max.

12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max. 96 PHOTO PHOTO ON/OFF Input SERI Related Information General terms and conditions... F-3 General precautions... P.9 MEASURE panasonic.net/id/pidsx/global Multi-functional D rail mounting slim sensor controller

More information

LOW-PROFILE SURFACE-MOUNT RELAY

LOW-PROFILE SURFACE-MOUNT RELAY TESTING LOW-PROFILE SURFACE-MOUNT RELAY TQ SMD RELAYS.6. RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6. mm.6 inch) Tape and reel

More information

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R MINIATURE POWER RELAY IN DS RELAY SERIES DSP- RELAYS DSPa DSP SPECIFICATIONS.. DSPa Coil (polarized) (at C F) Minimum mw power coil latching mw mw power coil latching mw.... Contact Arrangement a ab a

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS CSM_H3DS_DS_E_2_1 DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock.

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS Timers DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to

More information

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360 Absolute 60-mm-dia. Rotary Encoder CSM DS_E_7_1 Rugged Rotary Encoder Absolute model. External diameter of 60 mm. Resolution of up to 1,024 (10-bit). IP65 oil-proof protection. Strong shaft. Radial: 120

More information

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display

More information

Model Number Structure

Model Number Structure Single-phase Voltage Relay CSM DS_E_3_1 Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages or undervoltages. Manual resetting and automatically resetting supported

More information

Model Number Structure

Model Number Structure Current Sensor CSM DS_E Solid-state, Plug-in Current Sensor Applicable to motor overcurrent protection and 3-phase AC current detection. Inverse-type, start-up lock type, and instantaneous type overcurrent

More information

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications Latching Relay MMK CSM_MMK_DS_E_1_1 Mechanically Latching Relays Based on the MM Power Relay Low power consumption due to mechanical latch for economic operation. Relays with mixed coil specifications

More information

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal SPST Slim Power Relay for A switching Slim -mm width and miniature size. (20.08 12. mm) High switching capability A (20 VAC and VDC), and high contact reliability by crossbar-twin contact. Low power consumption

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks -A Load Compact: 20 x 15 x 10 mm (L x W x H). Low power consumption: 200 mw. Flux protection or plastic-sealed construction available.

More information

Ultraminiature Photoelectric Switches with Self-contained Amplifier

Ultraminiature Photoelectric Switches with Self-contained Amplifier Ultraminiature Photoelectric Switches with Self-contained Amplifier HPJ Series Fingertip-size, Provided with a various slit attachments. (six types) Fingertip-size 22 x 11 x 8 mm (thru scan model) 30 x

More information

DIS-5010A, DIA-512A. Data Acquisition System for Crash Test AUTOMOTIVE TEST EQUIPMENT

DIS-5010A, DIA-512A. Data Acquisition System for Crash Test AUTOMOTIVE TEST EQUIPMENT , Data Acquisition System for Crash Test 5-40 On-vehicle Data Logger for Crash Test On-vehicle Airbag Timer for Crash Test On-vehicle Data Logger for Crash Test On-vehicle unit designed to acquire 32 channels

More information

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5 DISPLAY VM-7 Page 1 of 5 No entry if additional Model Code / Additional Spec. Code ( spec. code is not specified. ) VM-702B /ALY /NB1 /CS1 /CS2 /TRP /TB Analysis Function Non-incendive Monitor Function

More information

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view) Built-in Amplifier Photoelectric Sensor E3S-A/B Revolutionary High-performance High-quality Sensor with Built-in Amplifier can be adjusted in seconds because the optical axis coincides with the mounting

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance 1 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1 guide... P.11~ General precautions... P.19 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global

More information

Compliant with European standards 1a/1c 6A Slim power relays

Compliant with European standards 1a/1c 6A Slim power relays PF (APF) VDE Compliant with European standards 1a/1c 6A Slim power relays PF RELAYS (APF) RoHS compliant FEATURES 1. High density mounting with mm.197 inch width Space saved with mm.197 inch slim type

More information

Solid-state Timer H3DE

Solid-state Timer H3DE Solid-state Timer H3DE CSM_H3DE_DS_E_3_2 DIN Track Mounted, Standard 22.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except

More information

E3X-NL. Employs OMRON's Unique Free Angle Optics Technology for Detecting Minute Differences in Glossiness. Optical Fiber Glossy Object Sensor

E3X-NL. Employs OMRON's Unique Free Angle Optics Technology for Detecting Minute Differences in Glossiness. Optical Fiber Glossy Object Sensor Authorised Distributors:- AS & AAIN INDIA PVT TD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) Tel : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Fiber Glossy Object

More information

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2 Selection guide Count - counters Function Totalising counters Display type Mechanical LCD Font panel dimensions (h x w) in mm 0 x 0 x. 0 x 60 x Number of display digits 6 digits or 6 digits (depending

More information

NA DigiParts GmbH. Small / Slim Object Detection Area Sensor

NA DigiParts GmbH. Small / Slim Object Detection Area Sensor 953 PHOTO PHOTO MEASURE ITY Object Area Sensor General terms and conditions... F-7 Related Information Glossary of terms... P.1455~ Cross-beam scanning system to detect slim objects Letters or business

More information

Distributed by: www.jameco.com 1-8-81-44 The content and copyrights of the attached material are the property of its owner. SLIM POLARIZED RELAY TN RELAYS.551. 9.8.86 FEATURES Small header area makes higher

More information

Pulse Scaler for DIN Rail Attachment

Pulse Scaler for DIN Rail Attachment Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary

More information

NA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects. Letters or business cards detectable!

NA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects. Letters or business cards detectable! 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information