DATA ACQUISITION and RECORDING SYSTEM with STATIC MEMORIES
|
|
- Griselda Norton
- 5 years ago
- Views:
Transcription
1 DATA ACQUISITION and RECORDING SYSTEM with STATIC Type: SAIMS Code: 984.0
2
3 GENERAL DATA First digital electronic equipment a Romanian concept in the military air force endowment - On - board: - MiG 21 LANCER - IAR 99 - IAR 93 - L39 - Incorporates thousands of flight hours experience; - Used for : - technical condition review before flight; - flight mission accomplishment review; - accident review; - Structure, figure 1: - on-board equipment: UAD, IP, PPD; - ground equipment: EPPD, ESPD, VTS, test-stands; - Permits acquisition of 28 parameters on-board the aircraft; - Acquisition maximum time: 2 hours; - Time to store information without any supply: 5 years; - Protection to shock, crush, fire, immersion in sea water and in the aircraft liquids; - Provides for table and graphic display of flight data. Page 3 of 12
4 EPPD IP UAD EIA VTS Figure 1 Page 4 of 12
5 UAD - DATA ACQUISITION UNIT - designed to acquire, condition and convert different signals of the aircraft; - types of signals : - 7 potentiometer signals (0-10 V); - 3 frequency signals (7-77 Hz); - 3 syncro type signals; - 1 continuous voltage signal; - 14 YES/NO signals series or shunt type. - sampling rate: up to 10 samples/second, in compliance with the signal; - provides for supervision of exceeding limits of a set of parameters; - complete self-test during running. - number of samples/second: 72; - conversion rate : 8 bits; Page 5 of 12
6 PROTECTED IP - PROTECTE D RECORDER - receivers data from UAD on a serial line (RS 232); - stores flight data in the protected memory; - storing capacity: 512 Kb; - complete self-test during operation; - time to take over data: 3 minutes; - supplies + 5 V, - 5 V and + 15 V voltages to the on-board equipment of SAIMS; - protected memory block resists to shock, crush, fire, immersion in compliance with TSO C-51-A; - transmits data to EPPD on serial line, by 115,200 bps. S. C. AEROFINA S. A. Page 6 of 12
7 PPD - DATA UP-TAKE PANEL - provides for easy data up-take from IP to EPPD; - contains warning signals for exceeding supervised parameters. Page 7 of 12
8 EPPD - PORTABLE DATA COPYING EQUIPMENT - designed to intercept flight data on ground; - provides for introduction of flight documentary data: date, aircraft no, pilot no, flight no; - provides for data up-take from 6 aircrafts and further data discharge in computer; - data discharge in computer: in serial line at a baud rate of 115,200 bps; - time to discharge : 3 minutes for each of the 6 recordings. Page 8 of 12
9 ESPD - GROUND DATA PROCESSING EQUIPMENT - components: - EIA - Intervention Equipment in case of emergency; - Programs Package to interpret data; - Cables, accessories. - Intervention equipment in case of emergency permits to extract data from the protected memories and transfer them in the computer in case of air crush; time to transfer data: 3 minutes. - Package of interpretation programs provides for data interpretation in table or graphic display. Page 9 of 12
10 INTERVENTION EQUIPMENT IN CASE OF EMERGENCY Page 10 of 12
11 VTS - SYSTEM TESTER - provides for the operative testing of the on-board equipment - UAD, IP - and for the localisation of failures for each operational block; - testing time: 2 minutes. Page 11 of 12
12 PARAMETERS GRAPHIC DISPLAY Page 12 of 12
ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...
Electronics & Software ICAM Type 5073A... Industrial Charge Amplifier for Applications in Manufacturing The ICAM charge amplifier (Industrial Charge Amplifier Manufacturing) converts the piezoelectric
More informationIN ELECTRICAL ENGINEERING - I C M E T CRAIOVA
Taking into account that power transformer is the major item of equipment in power systems, its correct operation is vital to system operation. It is well known that transformer failures are sometimes
More information5.5 SLG 75. Read/Write Devices Read/Write Antennas
5.5 SLG 75 Application area SLG 75 The SLG 75 ANT is a read/write device in the middle of the performance range. It can only be used with ANT 1, ANT 12, ANT 18 and ANT 30. The antennas can be very easily
More informationSIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions
Operating Instructions SIMEAS-T s Operating Instructions Transducer without auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101
More informationT/3000 T/3000. Substation Maintenance and Commissioning Test Equipment
T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY
More informationDIN Rail Kilowatt Hour Energy Meters
DIN Rail Kilowatt Hour Energy Meters Single Phase DIN Rail Kilowatt Hour Energy Meters DRK-1PPO-240 Single Phase 230V - 15A Direct Connected, Pulse Output This innovative two DIN module kilowatt hour energy
More informationUniversally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Instant value. Extreme values ors statistic measurements
Electronics & Software Charge Meter Universally Applicable for Piezoelectric Measuring Technology Type 5015A... This instrument can be used wherever mechanical quantities are measured with piezoelectric
More informationUniversally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Extreme values ors statistic measurements
Electronics & Software Charge Meter Type 5015A... Universally Applicable for Piezoelectric Measuring Technology This instrument can be used wherever mechanical quantities are measured with piezoelectric
More informationCharge Meter. Electronics & Software. Universally Applicable for Piezoelectric Measuring Technology. Type 5015A...
Electronics & Software Charge Meter Type 5015A... Universally Applicable for Piezoelectric Measuring Technology This instrument can be used wherever mechanical quantities are measured with piezoelectric
More informationGeneral Specifications
General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter
More informationPOSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire
POSICHRON Position Sensor Stick Design with Analog Specifications POSICHRON position sensor in stick design Protection class IP67 Measurement range 0... 100 up to 0... 5750 mm Absolute position measurement
More informationUSB GPS Dongle 65 channels With AGPS Function User s Manual
USB GPS Dongle 65 channels With AGPS Function User s Manual Pure white Shine silver Galaxy Black 1 General description of what GPS is and how it works GPS (Global Positioning System) is the only system
More informationPOSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire
Rod Profile with Analog Specifications POSICHRON position sensor in a stainless steel pressure case Protection class IP68 Compression-proof up to 15 bar Measurement range 0... 100 to 0... 5750 mm Absolute
More information0.01kV (0 to ±0.99 kv)
Handheld Electrostatic Meter Series IZH10 Easy-to-use handheld electrostatic meter Rated charge amount range: ±20.0 kv Minimum display unit: 0.1kV (±1.0 to ±20.0 kv) Check the current situation before
More informationR5 RIC Quickstart R5 RIC. R5 RIC Quickstart CONTENTS. Saab TransponderTech AB. Appendices. Project designation. Document title
Appendices 1 (10) Project designation R5 RIC Document title CONTENTS 1 Installation... 2 1.1 Connectors... 2 1.1.1 Power... 2 1.1.2 Video... 2 1.1.3 Sync... 3 1.1.4 RS232/ARP/ACP... 3 1.1.5 Radar data...
More informationN. TEST TEST DESCRIPTION
Multi function system for testing substation equipment such as: current, voltage and power transformers, over-current protection relays, energy meters and transducers Primary injection testing capabilities
More informationDTM.OCS.S/N - Modbus Level Transmitter
Digital Submersible Level Transmitter with Modbus Interface DTM.OCS.S/N - Modbus Level Transmitter CUSTOMER BENEFITS High precision digital level transmitter with standard Modbus interface Fast customization
More informationENCODING PHOTOCELLS MF6
ENCODING PHOTOCELLS MF6 Wall-mounted encoding photocells, 180 rotation and range of up to 20 mt. The code for the transmitted signal, which must be set at the time of installation, makes it possible to
More informationGAMMA 10 DIGITAL MULTIMETER
Gamma 10 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel
More informationIntermittent Vibration 0.075
FEATURES DESCRIPTION PLC-COM-CM1 Series Multi Drop Configuration of up to 32 Units Baud Rates Range from 300 to 38,400 bps 1:1/1:N/N:M (RS-422) Communication is Supported Full-Duplex (RS-422) and Half-Duplex
More informationApplications _. Features and benefits _. Technical assitance. Inclinometer probe servo accelerometer > LEA_EN_INC
LEA_EN_INC1001001 Inclinometer Probe Servo Accelerometer LEA_EN_INC1001001 Inclinometer Probe Servo Accelerometer Descrizione _ The inclinometer probe is used in geotechnical and structural monitoring
More informationInstallation and operating instructions
Installation and operating instructions GPS TILT-Module Version: V3.20120515 30302495-02-EN Read and follow these operating instructions. Keep these operating instructions in a safe place for later reference.
More informationElectronic Control Automotive for Proportional Valves 4 Solenoid
The command REP-A400 was designed to control up to 4 valves Proportional valves open loop (is those who do not have the transducer positioning inside) or feedback. The REP-A400 is a microcontroller device
More informationMID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN
Energy Management Energy Meter Type EM33 DIN Easy connections management Certified according to MID Directive (option PF only): see how to order below Other version available (not certified, option X):
More informationEnergy Management Energy Meter GM3T E GM3T-RS485 E
Energy Management Energy Meter GM3T E09 814 96 GM3T-RS485 E09 816 65 Certified according to MID Directive Product Description Three-phase energy meter with removable front LCD display unit. The same unit
More informationKMT - Kraus Messtechnik GmbH
KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com CTP8-Rotate 8 (4) channel telemetry
More informationTelemetrie-Messtechnik Schnorrenberg
Telemetrie-Messtechnik Schnorrenberg CTP8-Rotate 8 (4) channel telemetry for rotating applications like wheels or rotors, high signal bandwidth, 16bit, software programmable Inputs for STG, TH-K, ICP or
More informationAUTOMATIC WEATHER AND HYDROLOGICAL STATIONS
AUTOMATIC WEATHER AND HYDROLOGICAL STATIONS METEODATA/HYDRODATA-3000C SERIES Brochure nº 9722.0044 GEONICA, S.A. - Alejandro Rodríguez, nº 22-28039 Madrid - Spain Tel. +34 91 450 51 18 Fax +34 91 459 46
More informationEnergy Management Energy Analyzer Type EM210 MID
Energy Management Energy Analyzer Type Multi-use housing: for both DIN-rail and panel mounting applications MID annex MI-003 (Measuring Instruments Directive) compliant Class B (kwh) according to EN50470-3
More informationDigital insulation tester
Digital insulation tester C.A 6505 > > Insulation at 5 kv > > Wide measurement range from 10 kω to 10 TΩ > > Large backlit LCD screen, with digital display and bargraph > > Fixed test voltages and programmable
More informationRotary Measuring Technology
SSI or parallel interface Highest shock resistance on the market ( 2500 m/s2, 6 ms acc. to DIN IEC 68-2-27) Divisions: up to 16384 (14 bits), singleturn Housing Ø 58 mm IP 66 Various options (e.g. LATCH,
More informationN. TEST TEST DESCRIPTION
Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities
More informationMIT510/2, MIT520/2 and MIT1020/2
MIT510/2, MIT520/2 and MIT1020/2 Line supply or battery operated Digital/analog backlit display Measurement range to 15 TΩ (MIT510/2 and MIT520/2) and 35 TΩ (MIT1020/2) CAT IV 600 V safety rating Automatic
More informationMIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA
MIL Standard 461 G final release December 11 th, 2015 EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA CDN-UTP8 Ed. 3 - Universal The Swiss CDN company for data EMC and telecom
More informationSR32 line regen Converters
.1 Short description SR32 devices are AC/DC three-phase converters with a full digital control, which are active in the four quadrants to supply constant voltage to the DC link of the AMV32, AMD32, AVy
More informationHarris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR
Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model 6012-06XR Specifications & Dimensions 2 Theory of Operation 3 System Block Diagram 4 Operator Controls & Connectors 5 Test Connections
More informationWarfighter Information Network Solicitation #: W15P7T-13-R0059 DRS Network and Imaging Systems
Warfighter Information Network Solicitation #: W15P7T-13-R0059 DRS Network and Imaging Systems May 17, 2013 AirSystems_Tiered Testing_White Paper_MicrositeVersion_v2.docx DRAFT-12/8/2015 2:05 PM DRS Tactical
More informationCondition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:
ETP SYSTEM Condition-based maintenance of power transformers The predictive and condition based maintenance is nowadays accepted as the most efficient solution to guarantee the proper operation of critical
More informationOnline data sheet TTK70-AXA0-K02 TTK70 LINEAR ENCODERS
Online data sheet TTK70-AXA0-K02 TTK70 A B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Performance Measuring length Ordering information Other models and accessories
More informationIntelix DIGI-VGASD-S Installation Manual
Intelix DIGI-VGASD-S Installation Manual Introduction The Intelix DIGI-VGASD-S active send balun transmits VGA video, stereo audio, and IR or RS232 up to 350 feet over a single twisted pair cable. The
More informationmaxon document number:
maxon document number: 791272-04 1 Table of contents... 2 2 Table of figures... 3 3 Introduction... 4 4 How to use this guide... 4 5 Safety Instructions... 5 6 Performance Data... 6 6.1 Motor data... 6
More informationma/bcd Converter Model MFC-201 ma/bcd The MFC-201 ma/bcd Converter is a device designed to convert a DC current signal into BCD (8421) signals.
1 Definition ma/bcd Converter Model MFC-201 ma/bcd The MFC-201 ma/bcd Converter is a device designed to convert a DC current signal into BCD (8421) signals. 2 Operating Principle An electronic circuit
More information8PK-ST1520 Digital Earth Resistance Tester
8PK-ST1520 Digital Earth Resistance Tester Users Manual Index 1.INTRODUCTION... 2.SAFETY NOTES... 3.FATURES... 4.SPECIFICATIONS... 5.LAYOUT... 6.MEASURING METHODS... 7.MAINTENANCE... Page 1 2 3 4 5 6-7
More informationThis Chapter contains:
7 This Chapter contains: Table 7.1 Table 7-2 Table 7-3 Table 7-4 contains the general technical specifications for the MICROMASTER 430 inverter contains terminal tightening torques and the required cooling
More informationOnline data sheet TTK70-HXA0-K02 TTK70 MOTOR FEEDBACK SYSTEMS LINEAR HIPERFACE
Online data sheet TTK70-HXA0-K02 TTK70 TTK70-HXA0-K02 TTK70 A B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Performance Measuring step Measuring length Ordering information
More informationResolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )
PRAS1 Magnetic Angle Sensor with Analog Output Magnetic angle 0-360 in M12 housing Measurement range 0 to 360 Protection class IP67 / IP69K Analog output Stainless steel housing Non-contact with external
More informationTransmitter System USER S MANUAL. Light Series
Transmitter System USER S MANUAL Light Series Follow the indications and warnings given by the machine producer regarding the machine controlled by the radio remote control. The information contained in
More informationEnglish RACON SERIES II RADIO CONTROL SERVICE MANUAL
English 22.2.2007 RACON SERIES II RADIO CONTROL SERVICE MANUAL Read the instructions supplied with the product before installation and commissioning. Keep the instructions in a safe place for future reference.
More informationDesign of Flight and Engine Warnings and Parameter Display System
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE) e-issn: 2278-2834,p- ISSN: 2278-8735.Volume 9, Issue 5, Ver. II (Sep - Oct. 2014), PP 04-12 Design of Flight and Engine Warnings and
More informationLCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS
USER GUIDE INDUSTRIAL DATA COMMUNICATIONS LCM100 Line Carrier Modem It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of equipment. Product
More informationmulti-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER
multi-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER Model : DI-6400 Your purchase of this INSULATION TESTER marks a step forward for you into
More informationSafety through Competence. Short Form Catalogue. Measuring Testing Controlling World Class Hardware and Software
Safety through Competence Short Form Catalogue Measuring Testing Controlling World Class Hardware and Software MAVOLOG 20P Test Instrument for Monitoring Voltage Quality Electrical Engineering, Maintenance,
More informationDIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)
PERFORMANCES 12 ranges of AC current from 16 ma to 128 A peak AC permanent current up to 26 ARMS Nine ranges of DC permanent current from 16 ma to 12 A DC current ± 6mA or ± 10 ma stackable to AC current
More informationPXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet
PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet The most important thing we build is trust 250 MHz to 6 GHz RF signal conditioning module for multi- UE, MIMO and Smartphone testing Four full
More informationEnergy Management Energy Meter Type EM21 72R Retro-Fit
Energy Management Energy Meter Type EM21 72R Retro-Fit Including 3 miniature split-core current sensors 10mm (90A), 16mm (150A) and 24mm (250A) diameter holes Class A (kwh) according to EN50470-3 Class
More informationAIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)
Model:PFXLM4B01DDK PFXLM4B01DDC PFXLM4B01DAK PFXLM4B01DAC LT4000M Rear module Model Name Indication PFXLM4B01 D * * (1) (2) (3) (4) Notice to our valued customers who use LT4000M series (analog model)
More informationINSTALLATION AND MAINTENANCE MANUAL FOR P/N: D564-XXX-001 L864 RED MEDIUM INTENSITY BEACON
INSTALLATION AND MAINTENANCE MANUAL FOR P/N: D564-XXX-001 L864 RED MEDIUM INTENSITY BEACON Page 1 of 8 Contents Page List of Figures and Tables... 2 Reference Drawings... 2 Section 1: Overview... 3 Section
More informationQ.raxx A slimline RS / EC
The Q.raxx slimline product is based on the standardized 19 technology, one rack unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field of stationary
More informationDatalogger DL.OCS/N/RS485
Datalogger DL.OCS/N/RS485 Version: 18.02.2014 Technical Specifications Pressure measuring range (mh2o) 2... 5 > 5... 20 > 20... 250 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure, (1) > 200 bar
More informationFluke 712B and 714B Temperature Calibrators
Fluke 712B and 714B Temperature Calibrators Accuracy and Simplicity Technical Data For the temperature calibration professional that wants a highly accurate, easy-to-use, single function temperature calibrator
More informationCompany Profile Amertec Systems is a leading private manufacturer of electronic systems for the defense sector, having more than 20 years of experienc
Company Profile Amertec Systems is a leading private manufacturer of electronic systems for the defense sector, having more than 20 years of experience in system engineering, mechanical and electronic
More informationU-Pilot can fly the aircraft using waypoint navigation, even when the GPS signal has been lost by using dead-reckoning navigation. Can also orbit arou
We offer a complete solution for a user that need to put a payload in a advanced position at low cost completely designed by the Spanish company Airelectronics. Using a standard computer, the user can
More informationMars-Energo. Volt/mA Calibrator CALMAR-S. User s manual Edition 3.1
Mars-Energo Volt/mA Calibrator CALMAR-S User s manual Edition 3.1 Manufacturer: OOO NPP Mars-Energo Address: V.O. 13 Line, 6-8, office 41H, Saint-Petersburg, Russia, 199034 2017 MARS-ENERGO Table of contents
More informationResolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )
PRAS1 Magnetic Angle Sensor with Analog Output Magnetic angle 0-360 in M12 housing Measurement range 0 to 360 Protection class IP67 / IP69K Analog output Stainless steel housing Non-contact with external
More informationIntelix DIGI-VGASD-R Installation Manual
Intelix DIGI-VGASD-R Installation Manual Introduction The Intelix DIGI-VGASD-R active receiver balun transmits VGA video, stereo audio, and IR or RS232 up to 350 feet over a single twisted pair cable.
More informationAPPLICATIONS. Automotive
MEASUREMENT light ARRAYS DS2 SERIES The AREAscan family of the DS2 series covers controlled heights ranging from 150 to 2500mm, with 5m operating distances for high resolution versions, or 10m for low
More informationZ170REG. Universal converter module with galvanic insulation between 2 analog outputs
USER MANUAL EN Z170REG Z Line Universal converter module with galvanic insulation between 2 analog outputs Chapter index Page 1. Identification data 1 2. Preliminary warnings 2 3. Description and characteristics
More informationTHYFREC-VT110S 200V 1PH System 0.4 to 2.2kW 400V 3PH System 0.75 to 2.2kW QUICK START GUIDE
MEIDEN AC SPEED CONTROL EQUIPMENT THYFREC-VT110S 200V 1PH System 0.4 to 2.2kW 400V 3PH System 0.75 to 2.2kW QUICK START GUIDE NOTICE 1. Read this manual thoroughly before using the VT110S, and store in
More informationAn internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.
TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant
More informationA Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.
A Comparison Between MIL-STD and Commercial EMC Requirements Part 2 By Vincent W. Greb President, EMC Integrity, Inc. OVERVIEW Compare and contrast military (i.e., MIL-STD) and commercial EMC immunity
More informationWireless Transceivers for Fuel Level Sensors RUd-DF-232 RUd-DF-485. Instruction Manual Version # 2.1 VTAS IM
ОКP 42 1492 Wireless Transceivers for Fuel Level Sensors Version # 2.1 VTAS.421451.001 IM www.centronix.ru CONTENTS 1 INTRODUCTION.. 3 2 DESCRIPTION AND OPERATION... 3 2.1 Product s purpose... 3 2.2 Specifications...
More informationQ.raxx A101-8 slimline RS / EC
The Q.raxx slimline product is based on the standardized 19 technology, one rack mount unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field
More informationPRINCIPLE OF SEISMIC SURVEY
PRINCIPLE OF SEISMIC SURVEY MARINE INSTITUTE Galway, Ireland 29th April 2016 Laurent MATTIO Contents 2 Principle of seismic survey Objective of seismic survey Acquisition chain Wave propagation Different
More information8V General information. 2 Order data 8V
8V05.00-8V05.00- General information Modular mechanical design using plug-in modules Integrated line filter Integrated braking resistor All connections are made using plug-in connectors Integrated electronic
More informationProduct Information. Page 1 of 10
Product Information RT-1000.C Page 1 of 10 Edited by: RHOTHETA Elektronik GmbH Kemmelpark Dr.-Ingeborg-Haeckel-Str.1 82418 Murnau Germany : +49 8841 / 4879-0 : +49 8841 / 4879-14 Homepage: www.rhotheta.de
More informationDifferential pressure sensors
1 912 1912P02 QBM64/ 1912P01 QBM63/ Differential pressure sensors for air and non-aggressive gases, with a diaphragm sensing element QBM63/ QBM64/ With choice of pressure-linear or extracting-the-root
More informationProtection Class (IEC 529)
(W)GS2 Velocity Sensor with Analog or A/D converted synchronous serial output Specifications Velocity Sensor with Position Option Class IP50 Measurement Range: 0... 1500 mm to 0... 2500 mm 0... 59.06 in
More informationTECHNICAL DATASHEET #TDAX QUAD VALVE CONTROLLER P/N: AX SERIES
TECHNICAL DATASHEET #TDAX020500 QUAD VALVE CONTROLLER P/N: AX020500 SERIES Multiple Digital, Analog or PWM Command Inputs 4 Independent Proportional Outputs and 1 On/Off Output Standard Open Loop Control
More informationGAMMA 12 DIGITAL MULTIMETER
Gamma 12 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel
More informationLocal Asynchronous Communication. By S.Senthilmurugan Asst.Professor/ICE SRM University. Chennai.
Local Asynchronous Communication By S.Senthilmurugan Asst.Professor/ICE SRM University. Chennai. Bitwise Data Transmission Data transmission requires: Encoding bits as energy Transmitting energy through
More informationMGL Avionics Garrecht VT-0102 mode-s transponder Interface installation manual
MGL Avionics Garrecht VT-0102 mode-s transponder Interface installation manual Document date: September 2012 This document should be read in conjunction with the Garrecht VT-0102 installation manual General
More informationModel: Pro95 TRUE RMS MILLIAMP CLAMP METER
Model: Pro95 TRUE RMS MILLIAMP CLAMP METER TABLE OF CONTENTS 1. SAFETY INFORMATION... 1 2. GENERAL SPECIFICATION... 1 3. ELECTRICAL SPECIFICATION... 2 3-1 ACMA MEASUREMENT... 2 3-2 ACA MEASUREMENT...
More informationJA Audio Controller Data Sheet
TM JA95-001 Audio Controller Data Sheet Description The JA95-001 audio controller is a compact, lightweight unit that incorporates the latest technology, and is compatible with the current industry standard
More informationHAWK5000 Operators Manual
HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED
More informationP/N: AX06080X. TECHNICAL DATASHEET #TDAX06080X Triaxial Inclinometer SAE J1939 or CANopen 2 M12 Connector(s), IP67 with Electronic Assistant
TECHNICAL DATASHEET #TDAX06080X Triaxial Inclinometer SAE J1939 or CANopen 2 M12 Connector(s), IP67 with Electronic Assistant P/N: AX06080X Features: Reliable, real-time, accurate and stable slope angle
More informationSupervision and analyse of the electrical network EN50160 & POWER QUALITY
Supervision and analyse of the electrical network EN50160 & POWER QUALITY Controls the quality of the network following EN50160 and CEI 61000-3-6/7 Complies to the CEI 61000-4-30 class A Standard! Records
More informationINSTALLATION MANUAL KI 208, KI 209 NAVIGATION INDICATORS
RELEASED FOR THE EXCLUSIVE USE BY: AIRCRAFT ELECTRONICS ASSOCIATION h INSTALLATION MANUAL KI 208, KI 209 NAVIGATION INDICATORS MANUAL NUMBER 006-00140-0004 Revision 4, August 2002 RELEASED FOR THE EXCLUSIVE
More informationEARTH RESISTANCE TESTER
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com DIGITAL BST-ET52 EARTH RESISTANCE TESTER INSTRUCTION MANUAL Index 1. Introduction...
More informationSERVICE BULLETIN N F
SERVICE BULLETIN N F406-104 MANUFACTURER REFERENCE: N F406-104 N ATA: 27 Date: TITLE: Inspection of rudder control pedal torque tube EFFECTIVITY Model Serial Number F406 0001 to 0098 PURPOSE A pilot rudder
More informationALR-400 RADAR WARNING RECEIVER
AIBORNE DEFENSE SYSTEMS RADAR WARNING RECEIVER Defense and security systems in five continents indracompany.com RADAR WARNING RECEIVER Technical description leading edge field proven wideband digital reception
More information3 PHASE DIGITAL POWER CLAMP METER USERS MANUAL
PHASE DIGITAL POWER CLAMP METER USERS MANUAL CONTENTS Safety Precautions - - - - - - - - - - - - - - - - - - - - - - - - - - - Safety Information - - - - - - - - - - - - - - - - - - - - - - - - - - - Safety
More informationEnergy Management Energy Analyzer Type EM210
Energy Management Energy Analyzer Type EM210 Multi-use housing: for both DIN-rail and panel mounting applications Current inputs AV option: CT 5A Current inputs MV option: current sensor 333 mv (CTV series)
More informationEzOSD Manual. Overview & Operating Instructions Preliminary. April ImmersionRC EzOSD Manual 1
EzOSD Manual Overview & Operating Instructions Preliminary. April 2009 ImmersionRC EzOSD Manual 1 Contents Overview... 3 Features... 3 Installation... 3 1. Installation using an ImmersionRC camera and
More informationBW-IMU200 Serials. Low-cost Inertial Measurement Unit. Technical Manual
Serials Low-cost Inertial Measurement Unit Technical Manual Introduction As a low-cost inertial measurement sensor, the BW-IMU200 measures the attitude parameters of the motion carrier (roll angle, pitch
More informationLiquid level monitoring relay CM-ENS.2x
Data sheet Liquid level monitoring relay CM-ENS.2x The CM-ENS.2x is served to regulate and control liquid levels and ratios of mixtures of conductive fluids. It can be used for overflow protection, dry
More informationC I R R U S EMERGENCY DESCRIPTION A. Emergency Locator Transmitter (ELT)
EMERGENCY 1. DESCRIPTION A. Emergency Locator Transmitter (ELT) This airplane is equipped with a self-contained ELT. The ELT transmitter is installed immediately behind the aft cabin bulkhead. The ELT
More informationMeasuring Transducer MT4xx series Programmable AC Current Transducer MT418
Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 o RMS AC current or frequency measurements o Current auto range measurements up to 12 A o Frequency measurement range 16 400 Hz
More informationRotary Measuring Technology
Our ATEX encoders now also carry approval for Dust Flameproof-enclosure type of construction with approval for Zone 1 and 21 ExII2GEExdIICT6 and ExII2DIP6xT85 C Shaft ø 12 mm One type for every situation:
More information02/11/2015
Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine
More informationPES Eddy Current Proximity Sensor User s Manual P/N M8A-100
PES -110 Eddy Current Proximity Sensor User s Manual P/N 9431-09M8A-100 Safety Information The following manual contains information and warnings. They must be followed in order to keep the instrument
More information