High Temperature Velocity and Acceleration Sensor
|
|
- Ronald Copeland
- 5 years ago
- Views:
Transcription
1 359 High Temperature Velocity and Acceleration Sensor Bently Nevada* Asset Condition Monitoring Description The 359 High Temperature Velocity and Acceleration Sensor (HTVAS) provides a continuous acceleration and velocity output, allowing the customer to protect their machine with an velocity signal while simultaneously capturing the acceleration signal for machinery diagnostics. Its design is primarily for use with the 35/42M and 35/44M monitors. When attaching the HTVAS to a 35/42M or 35/44M monitor you must use the acceleration and velocity signals from the transducer on a separate channel pair (such as channels 1 and 3) or on separate monitors. The 359 High Temperature Velocity and Acceleration Sensor (HTVAS) separates the high-temperature sensing element from the signal conditioning electronics, with the two permanently connected via a hardline cable. This arrangement allows you to mount the sensing head on surfaces with temperatures as high as 482 C ( 9 F), while installing the signal conditioning electronics in a cooler location. Eliminating connections between the sensing head and its associated signal conditioning electronics also eliminates a significant source of potential transducer failures (connector problems). This achieves overall transducer system performance comparable to other case-mounted vibration transducers, but permits use at significantly higher temperatures. The main features of the 359 HTVAS are as follows: Velocity and acceleration output High temperature operation up to +482 C (+9 F) Electronics rated to +125 C (+257 F), survivable to +155 C (+311 F) Application Advisory If housing measurements are being made for overall protection of the machine, give thought to the usefulness of the measurement for each application. Most common machine malfunctions (imbalance, misalignment, etc.) originate at the rotor and cause an increase (or at least a change) in rotor vibration. For any housing measurement alone to be effective for overall machine protection, the machine must faithfully transmit a significant amount of rotor vibration to the bearing housing or machine casing, or more specifically, to the mounting location of the transducer. In addition, exercise care in the physical installation of the transducer. Improper installation can degrade the transducer s performance, and/or generate signals which do not represent actual machine vibration. Upon request, we can provide engineering services to determine the suitability of housing measurements for the machine in question and/or to provide installation assistance. Page 1 of 7
2 Specifications Specifications are between +2 C and +3 C (+68 F to +86 F) with machine casing vibration at 1 Hz (6 cpm) and with a 1 k load unless otherwise indicated. Electrical Power Requirements Input Voltage System Sensitivity over Extended Temperatures of 54 C to +399 C (-65 F to +75 F) and with the electronics between 54 C to +125 C (-65 F to +257 F), the output remains within ± 1% of 3.94 mv/mm/s (1 mv/in/s). Quiescent Current Transverse Sensitivity Amplitude Linearity -18 to -3 Vdc; -18 to 28 Vdc for hazardous area approval options. 6 ma nominal, no load. Less than 5% of axial sensitivity. Output Bias Voltage Velocity Range of 54 C to +482 C (-65 F to +9 F) and with the electronics between 54 C to +125 C (-65 F to +257 F), the output remains within ± 15% of 3.94 mv/mm/s (1 mv/in/s) Vdc. Mounted Resonant Frequency Maximum Cable Length Grounding Velocity Output Sensitivity Frequency Response 1% to 49 m/s 2 (5 g) peak overall acceleration. Greater than 15 khz. 35 metres (1 ft). Case isolated mv/mm/s (1 mv/in/s) ±5%. Broadband Noise Floor (5 Hz to 2 khz) Acceleration Output Sensitivity Frequency Response 127 mm/s (5 in/s)..5 mm/s rms (.2 in/s rms), max. 1.2 mv/m/s 2 (1 mv/g) ± 5%. 25 Hz to 4 khz (15 cpm to 24 kcpm) 5% with 35 metres (1 ft) of cable. 1 Hz to 1 khz (6 cpm to 6 kcpm) 3 db with 35 metres (1 ft) of cable. 4 Hz to 1 khz (24 cpm to 6 kcpm) 5% with 35 metres (1 ft) of cable. 25 Hz to 2 khz (15 cpm to 12 kcpm) 3 db with 35 metres (1 ft) of cable. System Sensitivity over Extended Temperatures of -54 C to +399 C (-65 F to +75 F) and with the electronics Page 2 of 7
3 between 54 C to +125 C (-65 F to +257 F), the output remains within ± 1% of 1.2 mv/m/s2 (1 mv/g). ATEX II 1 G Ex ia IIC T4 Output Bias Voltage Acceleration Range Broadband Noise Floor (5 Hz to 2 khz) of 54 C to +482 C (-65 F to +9 F) and with the electronics between 54 C to +125 C (-65 F to +257 F), the output remains within ± 15% of 1.2 mv/m/s2 (1 mv/g) Vdc. 49 m/s 2 (5 g). Hazardous Area Classification CSA/NRTL/C 147 mm/s 2 (1.5 mg) rms, max. For a detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (document 18M1756) located at the following website: Multiple approvals for hazardous areas certified by Canadian Standards Association in North America and by LCIE in Europe. Ex ia/aex ia for Class I Zone IIC Ta = 1ºC or Class I, Division 1, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; and Class III, Division 1, when installed with an approved zener barrier per BN drawing Ex nl IIC Class 1, Zone 2 Ta = -4ºC - 1ºC II 3 G Ex nl IIC T4 Electromagnetic Compatibility (CE Mark) EMC European Community Directives EMC Directive 24/18/EC Standards: EN 61326, Electrical Equipment for Measurement, Control, and Laboratory Use, EMC Requirements. CISPR 11, Radiated Emissions EN , Electro-Static Discharge EN , Radiated Immunity EN , Electrical Fast Transient EN , Surge Explosive Atmospheres European Community Directives: ATEX 1994/9/EC Standards: EN 679- EN EN For further certification and approvals information please visit the following website: Environmental Limits Operating and Storage Temperatures Sensor Mineral Insulated Cable Electronics -54 C to +482 C (-65 F to +9 F). -54 C to +482 C (-65 F to +9 F). -54 C to +125 C (-65 F to +257 F). Class I, Division 2 (non-incendive), Groups A, B, C, and D when installed per BN drawing Page 3 of 7
4 Soak Back Temperature Shock Survivability The electronics will survive temperature exposure of +155 C (+311 F) for four hours without failure. Electrical performance will not be met during this period. Integral Electronics Dimensions See Figure 1. Mounting Patch panel hub mount. Material 3 series stainless steel. Relative Humidity 19,62 m/s 2 (2 g) peak, maximum. Connector MIL-DTL-83723/9-16N with gold-plated 3 series stainless steel. Physical Sensor Dimensions Mounting Mounting Surface Material Integral Cable Diameter Material Bend Radius 1% condensing, nonsubmerged. Case is hermetically sealed. See Figure mm (1.188 in) square mounting hole pattern, 7.2 mm (.283 in) mounting holes (4 holes). 32 microinch rms. Nickel alloy ± 1.27 mm (.25 ±.5 in) 3 Series Stainless Mineral Insulated Integral Cable with Stainless Steel Overbraid. Minimum bend radius of 51 mm (2. in). System Weight (without field wiring) Mounting Angle.545 kg +.1 kg/m cable length (1.2 lb +.6 lb/in cable length), typical. Any orientation Ordering Information For a detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (document 18M1756) located at the following website: High Temperature Velocity and Acceleration Sensor 359 AXXX A: Integral Cable Length Option inches (.58 metres) inches (.66 metres) inches (.69 metres) inches (1.12 metres) inches (1.96 metres) inches (2.11 metres) inches (4. metres) inches (6. metres) inches (8. metres) inches (1. metres) HTVAS Field Interconnect Cable 3591 AXXX A: Cable Length 1 1 ft (3.5 metres) 4 4 ft (12.2 metres) Page 4 of 7
5 1. Stainless steel overbraided MI cable diameter through (typical), 4 places 3. Length UNF-2A 5. MIL-DTL-83723/9 connector Figure 1: Transducer Dimensional Drawing Dimensions are in millimetres [inches] Page 5 of 7
6 Phase Error ( ) Sensitivity (db) Velocity Frequency Response Velocity Phase Error Figure 2: Typical Velocity Amplitude and Phase Response Page 6 of 7
7 Phase Error ( ) Sensitivity (db) Acceleration Frequency Response Acceleration Phase Error Figure 3: Typical Acceleration Amplitude and Phase Response * Denotes a trademark of Bently Nevada, Inc., a wholly owned subsidiary of General Electric Company Bently Nevada, Inc. All rights reserved. Printed in USA. Uncontrolled when transmitted electronically Bently Parkway South, Minden, Nevada USA Phone: Fax: Page 7 of 7
Low Frequency Velocity Sensor
330505 Low Frequency Velocity Sensor Product Datasheet Bently Nevada* Asset Condition Monitoring Product Datasheet The Bently Nevada 330505 Low Frequency Velocity Sensor is specifically designed for hydroelectric
More informationthe 3500/44M Aeroderivitive GT Vibration Monitor for the
3500/44M Aeroderivitive GT Vibration Monitor Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 3500/44M Aeroderivitive GT Vibration Monitor is a fourchannel instrument designed
More informationОписание на пьезодатчики скорости. Модель
По вопросам продаж и поддержки обращайтесь: btn@nt-rt.ru www.bently.nt-rt.ru Архангельск (8182)63-90-72, Астана+7(7172)727-132, Белгород(4722)40-23-64, Брянск(4832)59-03-52, Владивосток(423)249-28-31,
More information3500/64M Dynamic Pressure Monitor
3500/64M Dynamic Pressure Monitor Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 3500/64M Dynamic Pressure Monitor is a single slot, fourchannel monitor that accepts input
More informationTK-3 Proximity System Test Kit
TK-3 Proximity System Test Kit Product Datasheet Bently Nevada* Asset Condition Monitoring Description The TK-3 Proximity System Test Kit simulates shaft vibration and position for calibrating Bently Nevada*
More informationprotim-r Module
200200 protim-r Module Bently Nevada* Asset Condition Monitoring Description The 200200 dual-input protim-r (DIN rail mount) provides 2 channels of measurement. All acceleration-to-velocity (A-V) channels
More informationTrendmaster * Dynamic Scanning Module
149744 Trendmaster * Dynamic Scanning Module Product Datasheet Bently Nevada * Asset Condition Monitoring Description The 149744 Trendmaster* Dynamic Scanning Module (DSM) is a compact rack-based data
More informationUnderwater Probes. Bently Nevada* Asset Condition Monitoring. Description
Underwater Probes Bently Nevada* Asset Condition Monitoring Description 3300 XL underwater probes are designed specifically for applications involving constant exposure to liquids, such as those in hydroelectric
More information1701/25 FieldMonitor Seismic Input Monitor for Velocity and Acceleration Input
1701/25 FieldMonitor Seismic Input Monitor for Velocity and Acceleration Input Bently Nevada Asset Condition Monitoring Description The 1701/25 FieldMonitor Seismic Input Monitor is a 2-channel device
More informationprotim-r Module
200200 protim-r Module Description The 200200 dual-input protim-r (DIN Rail mount) provides two channels of measurement. All acceleration-to-velocity (A-V) channels condition the signal from an accelerometer
More information1443 Series Accelerometers Specifications
Technical Data 1443 Series Accelerometers Specifications Catalog Numbers 1443-ACC-GP series, 1443-ACC-VO series, 1443-ACC-IS series, 1443-ACC-AT series, 1443-ACC-LF-T, 1443-ACC-HF-T Topic Page Sensor Selection
More informationPV 102. IECEx. Piezoelectric velocity sensor FEATURES. From the Vibro-Meter product line
FEATURES From the Vibro-Meter product line Designed for medium temperature industrial applications: 50 to +120 C ( 58 to +248 F) Frequency response: 6.0 to 2500 Hz: ±10 % to 5000 Hz: ±3 db Ultra low-noise
More information4-20 ma Vibration Transmitter, Top connector
4-20 ma Vibration Transmitter, Top connector Main Characteristics Atex Approved for zone 0, 1, 2. Can monitor machine as low as 180 RPM. Annular shear mode (better than obsolete compression design) Velocity
More informationprotim-c Module Bently Nevada* Asset Condition Monitoring
200250 protim-c Module Bently Nevada* Asset Condition Monitoring Description The 200250 dual-input protim-c (conduit mount) provides 2 channels of measurement. All acceleration-to-velocity (A-V) channels
More informationCE620. Piezoelectric accelerometer with integrated electronics. IECEx
Piezoelectric accelerometer with integrated electronics FEATURES» From the Vibro-Meter product line» Voltage output signal: 100 or 500 mv/ g» Frequency response: 2 Hz to 10 khz» Temperature range: 55 to
More informationAC AC AC
AC104.01-10 AC104.01-100 AC104.01-500 Description The hermetic sealed industrial piezoelectric accelerometer model 104 is design to monitor the vibration in harsh industrial environment. It uses the industry
More information3500/40M Proximitor Monitor
Specifications and Ordering Information 3500/40M Proximitor Monitor Description The 3500/40M Proximitor Monitor is a 4-channel monitor that accepts input from Bently Nevada proximity transducers, conditions
More informationModel 600A13. Very High Temperature ICP Accelerometer Kit. Installation and Operating Manual
Model 600A13 Very High Temperature ICP Accelerometer Kit Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-959-4464 24-hour
More informationElectrodynamic Velocity Sensor
PR9268 Specifications Sheet July 2018 Electrodynamic Velocity Sensor Mechanical velocity sensor for absolute vibration measurement of critical turbomachinery applications such as steam, gas and hydro turbines,
More informationUnderwater Probes. Description
Underwater Probes Description 3300 XL underwater probes are designed specifically for applications involving constant exposure to liquids, such as those in hydroelectric plants or sewage treatment facilities.
More informationIP26 Series Current to Pneumatic Converter
Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear
More informationIntrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications
More informationIPC 704. Signal conditioner FEATURES. For CA piezoelectric accelerometers and CP dynamic pressure transducers
Signal conditioner FEATURES For CA piezoelectric accelerometers and CP dynamic pressure transducers Configurable high-pass and low-pass filters Frequency range: 0.5 Hz to 20 khz Optional integrator to
More informationTemposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet
Temposonics Magnetostrictive Linear Position Sensors ET Analog High operating temperature Compact sensor housing ATEX / IECEx / CEC / NEC certified MEASURING TECHNOLOGY The absolute, linear position sensors
More informationAccutech DP20. Wireless differential pressure field unit
Accutech DP20 Wireless differential pressure field unit 1 The Accutech DP20 differential pressure field unit provides differential pressure data in a variety of ranges up to +/-300in H 2 0. Both traditional
More informationProximity Transmitters and Seismic Vibration Transmitters
TM016 Velocity/ Acceleration Vibration Transmitter Introduction The TM016 is a solid state loop powered transmitter which provides a 4-20mA output proportional to the machine case vibration level. The
More informationFOUNDATION Fieldbus Junction Box
Installation Instructions FOUNDATION Fieldbus Junction Box Catalog Number 1788-FBJB4R, 1788-FBJB6 Topic Page Important User Information 2 About the Junction Boxes 3 Additional Resources 3 Installation
More informationSKF Vibration Sensors Catalog
SKF Vibration Sensors Catalog Vibration sensors Sensor selection, installation and mounting Cables and connectors Mounting accessories Contents Introduction.......................................... 3
More informationXM Monitoring Modules Specifications
Technical Data XM Monitoring Modules Specifications Catalog Numbers 1440 series The XM series of intelligent I/O modules process, in real-time, the critical parameters used to assess the current health
More informationModel 626B01. Low Frequency Industrial ICP Accelerometer. Installation and Operating Manual
Model 626B01 Low Frequency Industrial ICP Accelerometer Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-959-4464 24-hour
More informationADRE for Windows / DAIU
ADRE for Windows / DAIU Description ADRE for Windows Software (Automated Diagnostics for Rotating Equipment) and the 208 DAIU/208-P DAIU (Data Acquisition Interface Unit) is a portable system for multi-channel
More informationAccutech GP10. Wireless gauge pressure field unit
Accutech GP10 Wireless gauge pressure field unit 1 The Accutech GP10 wireless gauge pressure field unit provides pressure data in a variety of ranges from 250 to 10000 PSIG. With its integrated and highly
More informationAccutech AM20. Wireless acoustic monitor field unit
Accutech AM20 Wireless acoustic monitor field unit 1 The Accutech AM20 wireless acoustic monitor field unit monitors pressure relief valves, steam traps, automatic tank cleaning (CIP) systems, and other
More informationAero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.
4-170 Piezoelectric Accelerometer The CEC 4-170 accelerometer is a self-generating, piezoelectric accelerometer designed for medium temperature vibration measurement applications. This instrument provides
More informationKeysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview
Keysight Technologies 8745C 1 MHz to 18 GHz Preamplifier Technical Overview 2 Keysight 8745C 1 MHz to 18 GHz Preamplifier Technical Overview Introduction The Keysight Technologies, Inc. 8745C preamplifier
More informationSRS SEALED ROTARY SENSORS
SRS SEALED ROTARY SENSORS Innovation In Motion INNOVATION IN MOTION Penny+Giles SRS280 sealed rotary sensors and SRS880 submersible rotary sensors have been specially developed to provide maximum performance
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationModel 640B ma Output Velocity Sensor. Installation and Operating Manual
Model 640B02 4-20 ma Output Velocity Sensor Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-959-4464 24-hour SensorLine:
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationCSI 9330 Vibration Transmitter
Machinery Health Management O-9330-110512 Product Data Sheet November 2012 CSI 9330 Vibration Transmitter n Continuously monitors critical machinery in process applications and other industrial environments
More informationFisher 646 Electro Pneumatic Transducer
Product Bulletin D101374X012 646 Transducer Fisher 646 Electro Pneumatic Transducer The Fisher 646 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a 4 to 20 milliampere
More informationPart Number Revision NC, May Low Frequency Velocity Sensor Operation and Maintenance Manual
Part Number 169873-01 Revision NC, May 2005 330505 Low Frequency Velocity Sensor Operation and Maintenance Manual Copyright 2005 Bently Nevada LLC. All Rights Reserved. The information contained in this
More informationОписание на модули интерфейса управления. Модель 1701/22
По вопросам продаж и поддержки обращайтесь: btn@nt-rt.ru www.bently.nt-rt.ru Архангельск (8182)63-90-72, Астана+7(7172)727-132, Белгород(4722)40-23-64, Брянск(4832)59-03-52, Владивосток(423)249-28-31,
More information26 Endevco Isotron accelerometers
Isotron accelerometers Typical applications > Aircraft flight testing > Ground vibration testing > Automotive ride quality testing > Product testing > Quality assurance > Research and development > Test
More informationAccutech AP10. Wireless absolute pressure field unit
Accutech AP10 Wireless absolute pressure field unit 1 The Accutech AP10 wireless absolute pressure field unit provides pressure data in a variety of ranges from 30 to 250PSIA. With its integrated and highly
More informationIntrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F,
More information9330 Vibration Transmitter
Reliability Solutions Product Data Sheet June 2017 9330 Vibration Transmitter Continuously monitors critical machinery in process applications and other industrial environments Interfaces with existing
More informationKeysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview
Keysight Technologies 8745C 1 MHz to 18 GHz Preamplifier Technical Overview 2 Keysight 8745C 1 MHz to 18 GHz Preamplifier Technical Overview Introduction The Keysight Technologies, Inc. 8745C preamplifier
More informationNUCLEARENVIRONMENT VELOCITY - TO-DISPLACEMENTCONVERTER MOD~L BENTL NEVADA
Manual No. TW8029360' NUCLEARENVIRONMENT VELOCITY - TO-DISPLACEMENTCONVERTER MOD~L 232-691 BENTL NEVADA Y @ 8ENTLY NEVADA r'\ V..WoridWider~serVice... Copyright
More informationModel 629A31. Precision Triaxial Industrial ICP Accelerometer. Installation and Operating Manual
Model 629A31 Precision Triaxial Industrial ICP Accelerometer Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-959-4464
More informationTF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples
More informationFisher 4200 Series Electronic Position Transmitters
Product Bulletin D200357012 4200 Series Transmitter Fisher 4200 Series Electronic Position Transmitters Fisher 4200 Series electronic position transmitters (figure 1 and 2) combine field-proven electronic
More informationTemposonics. Magnetostrictive Linear Position Sensors. ET Start/Stop Data Sheet. High operating temperature Compact sensor housing ATEX certified
Temposonics Magnetostrictive Linear Position Sensors ET Start/Stop High operating temperature Compact sensor housing ATEX certified The Measurable Difference Temposonics ET Start/Stop MEASURING TECHNOLOGY
More informationAcceleration Sensor AS - 022
1 Application Acceleration Sensor AS - 022 The acceleration sensor AS-022 is used for measurement of vibration acceleration. Fig. 1 Acceleration Sensor AS - 022 2 Measuring Principle 3 Technical Data Acceleration
More informationMDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features
MDEX Torque transducer CS-T-04-MDEX Special features - Explosion proof acc. to ATEX 95 - Exx II 2 G Ex deq IIC T4 - Nominal (rates) torque of 100kNm, 130kNm and 150kNm - HBM Accuracy Class 0,1 - Digital
More informationCSI 9420 Wireless Vibration Transmitter
Machinery Health Management O-9420 Product Data Sheet August 2010 CSI 9420 Wireless Vibration Transmitter n Accurately monitors vibration and temperature in hard-toreach locations n Provides complete vibration
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant
More informationICARUS ELECTRONIC GAS VOLUME CONVERTER
ICARUS ELECTRONIC GAS VOLUME CONVERTER 1. INTRODUCTION 2. TECHNICAL DETAILS ICARUS is an electronic volume converter which, combined with a gas meter, provides the gas measurement in Sm3, calculated at
More informationED701 General Industry Pressure Transmitter
ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationPressure transmitter AKS 32 and AKS 33
Data sheet Pressure transmitter AKS 32 and AKS 33 AKS 32 and AKS 33 are pressure transmitters that measure a pressure and convert the measured value to a standard signal: y 1 5 V DC or 0 10 V DC for AKS
More informationV8 Vibration Test Systems
V8 V8 Vibration Test Systems V8-440 Shaker system: configuration and performance parameters V8-440 Metric American Armature diameter 440 mm 17.3 in Sine force peak (stabilised) 57,827 N 13,000 lbf Sine
More informationRotary Measurement Technology Incremental Encoders
-20 to 60 C Temperature Shock/vibration resistant Short-circuit protection Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection
More informationJAQUET DSD.7x. Dual Channel Hall Effect Speed Sensor for Railway Applications Compliant with EN Product identification.
JAQUET DSD.7x Dual Channel Hall Effect Speed Sensor for Railway Applications Compliant with EN 50155 General Function The speed sensors family DSD.7x are suitable for generating two 90 phase-shifted square
More informationWIRELESS INSULATOR POLLUTION MONITORING SYSTEM
SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power
More informationHead mounted Temperature Transmitter TF02/TF02-Ex
Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement
More informationHigh precision measurement system for current and voltage IHC-A/B-RM01/03
Measurement Offset-free and low-noise 16 bit data acquisition system ISA-ASIC Internal sample rate 3,500 Hz Communication Standard RS232- or RS485 interface Advantages Direct measurement on the bus bar
More informationAccutech TC10. Wireless thermocouple temperature field unit
Accutech TC10 Wireless thermocouple temperature field unit 1 The Accutech TC10 wireless thermocouple temperature field unit provides temperature data using standard J, K, S and T-type thermocouples. Probes
More informationCSI 9420 Wireless Vibration Transmitter
Machinery Health Management O-9420 Product Data Sheet November 2012 CSI 9420 Wireless Vibration Transmitter n Accurately monitors vibration and temperature in hard-to-reach locations n Provides complete
More informationInductive sensor slot-type SI2-K08-AP7
SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type
More information847H. Description. Features. Specifications
847H Bulletin 847H High Performance Industrial Incremental Encoders provide code disk resolutions of up to 65536 pulses per revolution at a signal frequency response of 820 khz. The 847H can provide 65536
More informationAccelerometer Catalogue
ccelerometer Catalogue EEx Types: 4391E, 574, 5874, 8326 Non EEx Types: 4391, 8315, 8324, 8325, 8327, 8331, 8332 Brüel & Kjær Vibro has more than 5 years experience in the design, manufacture and application
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationGS550-CSA/ATEX-CE. GS550 for Hazardous Locations. Features: Applications: General Description:
Features: All stainless steel enclosure AISI-304 Weather resistant 2x20 characters text display with backlight 16,000 events datalogger USB port for datalogger download or firmware / load charts update
More informationUltra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26
Electronic pressure measurement Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26 WIKA data sheet PE 87.07 Applications Gas panels for OEM tools Semiconductor, flat panel display and
More informationT22. Torque transducer. Special features. Data sheet
T22 Torque transducer Special features - Nominal (rated) torques 0.5 Nm, 1 Nm, 2 Nm, 5 Nm, Nm, Nm, 50 Nm, 0 Nm, 0 Nm, 500 Nm and 1 knm - Nominal (rated) rotational speed up to 000 rpm (depending on measuring
More informationIncremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution
Features Robust, compact housing Two bearings with large distance, one at each end High shaft load up to 450 N Shock resistant up to 250 g Shaft insulation up to 2.8 kv Highest operating speed 10000 rpm
More informationSubmersible pressure sensor For oils and fuels Model LF-1
Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run
More informationIntrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE
More informationAccutech AI10 & AV10. Wireless multi-input field unit
ccutech I10 & V10 Wireless multi-input field unit 1 Ideal for adding wireless capabilities to existing or new wired measurement sensors such as radar tank gauges, flow meters and chemical analyzers, the
More informationDifferential-Hall-Effect based Sensors Ex ia for Detection of Speed and Direction of Rotation in Hazardous Areas Zone 0 or 1 Series A5S1DD3 / A5S1DS3
A5S1 ifferential-hall-effect based Sensors Ex ia for etection of Speed and irection of Rotation in Hazardous Areas Zone 0 or 1 Series A5S1 Overall View A5S1 sensors the best choice for demanding applications
More informationIntrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751
Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable
More informationPD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description
Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer
More informationTQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES
Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES Non-contacting measurement system based on eddy current principle Certified for use in potentially
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationNI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer
NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer This document lists specifications for the NI PXI-2797 terminated multiplexer module. All specifications are subject to change without
More informationNI PXI-2557 Specifications
NI PXI-2557 Specifications 2.5 GHz 75 8 x 1 Multiplexer (SP8T) This document lists specifications for the NI PXI-2557 multiplexer module. All specifications are subject to change without notice. Visit
More informationNI PXI-2555 Specifications
NI PXI-2555 Specifications 2.5 GHz Terminated 4 x 1 Multiplexer (SP4T) This document lists specifications for the NI PXI-2555 multiplexer module. All specifications are subject to change without notice.
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationOnline data sheet ACM36-L1K0-K01 ACS/ACM36 ABSOLUTE ENCODERS
Online data sheet ACM36-L1K0-K01 ACS/ACM36 ACM36-L1K0-K01 ACS/ACM36 A B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Performance Number of steps per revolution Number
More informationSubmersible pressure sensor For water and wastewater Model LW-1
Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and
More informationINDUSTRIAL VIBRATION SENSOR SELECTION MADE EASY
SENSORS FOR RESEARCH & DEVELOPMENT WHITE PAPER #28 INDUSTRIAL VIBRATION SENSOR SELECTION MADE EASY NINE QUESTIONS TO SUCCESSFULLY IDENTIFY THE SOLUTION TO YOUR APPLICATION www.pcb.com info@pcb.com 800.828.8840
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationGS550-CSA. GS550-CSA class 1 division 2 specifications. Features: Applications: General Description:
Features: : multi-sensor stainless steel display /receiver class 1 division 2 specifications All stainless steel enclosure AISI-304 Weather resistant 2x20 characters text display with backlight 16,000
More informationTemposonics. Magnetostrictive Linear Position Sensors. TH SSI Data Sheet
Temposonics ostrictive Linear Position Sensors TH SSI ATEX / IECEx / CEC / NEC / EAC Ex certified / Japanese approval Continuous operation under harsh industrial conditions Flameproof / Explosionproof
More informationTQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES
: TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner TQ 402 & TQ 412 / EA 402 / IQS 452 FEATURES Non-contacting measurement system based on eddy current principle Certified
More informationNOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog
NOVOHALL Rotary Sensor non-contacting Series RSC2800 analog The RSC 2800 sensor utilizes a contactless magnetic measurement technology to determine the measured angle. Unlike conventional Hall sensors,
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More information